LG Multi Type Air Conditioner SERVICE MANUAL LG CAUTION website http://www.lgservice.com • BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. • ONLY FOR AUTHORIZED SERVICE PERSONNEL. MODEL • Indoor Unit: • Outdoor Unit: A3UH363FA0(LMO360H) A3UC363FA0(LMO360C) A2UH243FA0(LMO240H) A2UC243FA0(LMO240C) Room Type AMNH093D4L0(LMI090HP) AMNC093D4L0(LMI090CP) AMNH123DEL0(LMI120HP) AMNC123DEL0(LMI120CP) AMNH093APM0(LMA090HP) AMNC093APM0(LMA090CP) AMNH123APM0(LMA120HP) AMNC123APM0(LMA120CP) Art Cool Type
91

Multi Type Air Conditioner - SERVICE MANUAL

Mar 05, 2023

Download

Documents

Khang Minh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Multi Type Air Conditioner - SERVICE MANUAL

LGMulti Type Air ConditionerSERVICE MANUAL

LG

CAUTION

website http://www.lgservice.com

• BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.

• ONLY FOR AUTHORIZED SERVICE PERSONNEL.

MODEL • Indoor Unit:

• Outdoor Unit: A3UH363FA0(LMO360H)A3UC363FA0(LMO360C)A2UH243FA0(LMO240H)A2UC243FA0(LMO240C)

Room Type

AMNH093D4L0(LMI090HP)AMNC093D4L0(LMI090CP)AMNH123DEL0(LMI120HP)AMNC123DEL0(LMI120CP)

AMNH093APM0(LMA090HP)AMNC093APM0(LMA090CP)AMNH123APM0(LMA120HP)AMNC123APM0(LMA120CP)

Art Cool Type

Page 2: Multi Type Air Conditioner - SERVICE MANUAL

2 Multi type Air Conditioner

Multi type Air Conditioner Service Manual

TABLE OF CONTENTSModel Number Nomenclature ....................................................................................................................3

Symbols Used in this Manual ...................................................................................................................4Safety Precautions......................................................................................................................................5Dimensions................................................................................................................................................11

Indoor Unit.............................................................................................................................................11Outdoor Unit ...........................................................................................................................................12

Product Specifications .............................................................................................................................13Installation .................................................................................................................................................15

Installation Parts.....................................................................................................................................15Installation Tools.....................................................................................................................................15Select the best location .........................................................................................................................16Piping length and elevation ....................................................................................................................17Fixing Installation Plate(Standart Type)..................................................................................................18Preparing work for Installation (Artcool Type Only) ................................................................................19

Flaring Work and Connection of Piping..................................................................................................21Flaring work............................................................................................................................................21Connecting the Piping ............................................................................................................................22

Connecting the Cable between Indoor Unit and Outdoor Unit .............................................................30Connect the cable to the Indoor unit. .....................................................................................................30Connect the cable to the Outdoor unit....................................................................................................31Connection method of the connecting cable(Example) ..........................................................................32Connect the cable to the indoor unit.......................................................................................................33

Checking the Drainage, Forming the Pipings and Long Pipe Setting .................................................34Checking the drainage............................................................................................................................34Forming the piping..................................................................................................................................35

Air Purging and Evacuation .....................................................................................................................36Checking method ...................................................................................................................................36Evacuation..............................................................................................................................................37

Charging ....................................................................................................................................................38Test Running .............................................................................................................................................39Operation ...................................................................................................................................................40

Function of control..................................................................................................................................40Function of Indoor Unit ...........................................................................................................................45Function of Outdoor Unit ........................................................................................................................47Remote Control Operation .....................................................................................................................48

Disassembly ..............................................................................................................................................49Indoor Unit..............................................................................................................................................49

Schematic Diagram...................................................................................................................................54Electronic Control Device .......................................................................................................................54Wiring Diagram.......................................................................................................................................58Components Locations...........................................................................................................................59

Troubleshooting Guide .............................................................................................................................64Troubleshooting Guide............................................................................................................................64Self-diagnosis Function ..........................................................................................................................66Cycle Troubleshooting Guide..................................................................................................................67Electronic Parts Troubleshooting Guide .................................................................................................68Error Code..............................................................................................................................................73

2-way, 3-way Valve ....................................................................................................................................77Exploded View & Replacement Parts List ..............................................................................................81

Indoor Unit..............................................................................................................................................81Indoor Unit..............................................................................................................................................87

Page 3: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 3

Model Number Nomenclature

Model Number NomenclatureIndoor Unit

Outdoor Unit

AMN H 309 4D A 0

Serial Number

A3U H 336 F A 0

Electrical Ratings

MPS Variable Multi System Indoor Unit

Model TypeH: Heat Pump C: Cooling Only

Ex) 9,000 Btu/h '09', 12,000 Btu/h '12'

Nominal Cooling Capacity in Btu/h

Electrical Rating 3: 1Ø, 208~230V, 60Hz

Chassis Name

Indoor Unit TypeWall mounted split D : D- look type L : L- look type G : G- look type M : M- look type N : N- look type Artcool typeA : standard/wide type D : Deluxe type

B : Ceiling Concealed Duct V : Ceiling & Floor(Convertible)

FunctionA : Basic, L : Nano Plasma + Auto Clean(Wall Mounted)C: Plasma(Ceiling Cassette), G: Low Static Motor

ART COOL(DELUXE) Type Front Panel Color B : Blue, D : Wood, M : Metal, R : Mirror, W : White

R-410A MPS Variable Multi System Outdoor UnitAnd No. of Connectable Indoor Units

Ex) A3U : Connectable max. 2 Indoor Units

Model TypeH: Heat Pump C: Cooling Only

Ex) 24,000 Btu/h '24', 36,000 Btu/h '36'

Nominal Cooling Capacity in Btu/h

3: 1Ø, 208~230V, 60Hz

Multi Type

Function A : Basic

F : Free Joint Multi Type

Serial Number

Page 4: Multi Type Air Conditioner - SERVICE MANUAL

4 Multi type Air Conditioner

Model Number Nomenclature

Combination table

A B C Total Unit-A Unit-B Unit-C Total Unit-A Unit-B Unit-C Total (Btu/h.w) (w/w)

9 9 9000 9000 1320 5.9 6.8 9000 9000 1550 7.0 5.8 1.7

12 12 12000 12000 1320 5.9 9.1 12000 12000 1410 6.3 8.5 2.5

9 9 18 9000 9000 18000 2180 9.8 8.3 9000 9000 18000 2160 9.8 8.3 2.4

9 12 21 9000 12000 21000 2200 9.9 9.5 9000 12000 21000 2160 9.8 9.7 2.8

12 12 24 12000 12000 24000 2200 9.9 10.9 12000 12000 24000 2160 9.8 11.1 3.3

9 9 9 27 9000 9000 9000 27000 3650 16.5 7.4 9000 9000 9000 27000 3300 14.9 8.2 2.4

9 9 12 30 9000 9000 12000 30000 3650 16.5 8.2 9000 9000 12000 30000 3340 15.0 9.0 2.6

9 12 12 33 9000 12000 12000 33000 3650 16.5 9.0 9000 12000 12000 33000 3340 15.0 9.9 2.9

12 12 12 36 12000 12000 12000 36000 3680 16.6 9.8 12000 12000 12000 36000 3340 15.0 10.8 3.2

1 UNIT

COPOperationCombination(k Btu)

Cooling

2 UNIT

3 UNIT

Heating

Capacity (Btu/h) Input(W)

Current(A)

EER(Btu/h.w)

Capacity (Btu/h) Input(W)

Current(A)

Notes :1.Cooling Capacity is based on : indoor temp. 26.7°C(80.1°F)DB, 19.4°C(66.9°F)WB; outdoor temp. 35°C(95°F)DB, 23.9°C(75°F)WB

2.Heating Capacity is based on : indoor temp. 21.1°C(70°F)DB, 15.6°C(60.1°F)WB; outdoor temp. 8.3°C(46.9°F)DB, 6.1°C(43°F)WB

3.The total ability of connected a indoor unit is up to 24k Btu/h

This symbol alerts you to the risk of electric shock.

This symbol alerts you to hazards that could cause harm to theair conditioner.

This symbol indicates special notes.NOTICE

Symbols Used in this Manual

Page 5: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 5

Safety Precautions

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions mustbe followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is

classified by the following indications.

Meanings of symbols used in this manual are as shown below.

WARNING

CAUTION

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to properties only.

WARNING Installation

Be sure not to do.

Be sure to follow the instruction.

Do not use a defective or under-rated circuit breaker. Use thisappliance on a dedicated circuit.

• There is risk of fire or electricshock.

For electrical work, contact thedealer, seller, a qualified electrician,or an Authorized Service Center.

• Do not disassemble or repair theproduct. There is risk of fire orelectric shock.

Always ground the product.

• There is risk of fire or electricshock.

Install the panel and the coverof control box securely.

• There is risk of fire or electricshock.

Always install a dedicated cir-cuit and breaker.

• Improper wiring or installation maycause fire or electric shock

Use the correctly rated break-er or fuse.

• There is risk of fire or electricshock.

Page 6: Multi Type Air Conditioner - SERVICE MANUAL

6 Multi type Air Conditioner

Safety Precautions

Do not modify or extend thepower cable.

• There is risk of fire or electricshock.

Do not install, remove, or re-install the unit by yourself(customer).

• There is risk of fire, electric shock,explosion, or injury.

Be cautious when unpackingand installing the product.

• Sharp edges could cause injury.Be especially careful of the caseedges and the fins on the con-denser and evaporator.

For installation, always con-tact the dealer or anAuthorized Service Center.

• There is risk of fire, electric shock,explosion, or injury.

Do not install the product on adefective installation stand.

• It may cause injury, accident, ordamage to the product.

Be sure the installation areadoes not deteriorate with age.

• If the base collapses, the air condi-tioner could fall with it, causingproperty damage, product failure,and personal injury.

Do not let the air conditionerrun for a long time when thehumidity is very high and adoor or a window is left open.

• Moisture may condense and wet ordamage furniture.

Take care to ensure thatpower cable could not bepulled out or damaged duringoperation.

• There is risk of fire or electricshock.

Do not place anything on thepower cable.

• There is risk of fire or electricshock.

Page 7: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 7

Safety Precautions

Do not allow water to run intoelectric parts.

• It may cause There is risk of fire,failure of the product, or electricshock.

Do not store or use flammablegas or combustibles near theproduct.

• There is risk of fire or failure ofproduct.

Do not use the product in atightly closed space for a longtime.

• Oxygen deficiency could occur.

When flammable gas leaks,turn off the gas and open awindow for ventilation beforeturn the product on.

• Do not use the telephone or turnswitches on or off. There is risk ofexplosion or fire

If strange sounds, or small orsmoke comes from product.Turn the breaker off or discon-nect the power supply cable.

• There is risk of electric shock orfire.

Stop operation and close thewindow in storm or hurricane.If possible, remove the prod-uct from the window beforethe hurricane arrives.

• There is risk of property damage,failure of product, or electric shock.

Do not plug or unplug thepower supply plug duringoperation.

• There is risk of fire or electricshock.

Do not touch(operate) theproduct with wet hands.

• There is risk of fire or electricalshock.

Do not place a heater or otherappliances near the powercable.

• There is risk of fire and electricshock.

Gasolin

Page 8: Multi Type Air Conditioner - SERVICE MANUAL

8 Multi type Air Conditioner

Safety Precautions

Do not open the inlet grill of the productduring operation. (Do not touch the elec-trostatic filter, if the unit is so equipped.)

• There is risk of physical injury,electric shock, or product failure.

When the product is soaked(flooded or submerged), contactan Authorized Service Center.

• There is risk of fire or electricshock.

Be cautious that water couldnot enter the product.

• There is risk of fire, electric shock,or product damage.

Ventilate the product from time to time whenoperating it together with a stove, etc.

• There is risk of fire or electric shock.

Turn the main power off when cleaning ormaintaining the product.

• There is risk of electric shock.

When the product is not be used for a long time, dis-connect the power supply plug or turn off the breaker.

• There is risk of product damage or failure, or unintend-ed operation.

Take care to ensure that nobody could step onor fall onto the outdoor unit.

• This could result in personal injury and product dam-age.

Always check for gas (refrigerant) leak-age after installation or repair of product.

• Low refrigerant levels may causefailure of product.

Install the drain hose to ensure thatwater is drained away properly.

• A bad connection may cause waterleakage.

Keep level even wheninstalling the product.

• To avoid vibration or water leak-age.

CAUTION Installation

90°

Page 9: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 9

Safety Precautions

Do not block the inlet or outletof air flow.

• It may cause product failure.

Use a soft cloth to clean. Donot use harsh detergents, sol-vents, etc.

• There is risk of fire, electric shock,or damage to the plastic parts ofthe product.

Do not touch the metal parts ofthe product when removing theair filter. They are very sharp!

• There is risk of personal injury.

Do not install the productwhere the noise or hot airfrom the outdoor unit coulddamage the neighborhoods.

• It may cause a problem for yourneighbors.

Use two or more people to liftand transport the product.

• Avoid personal injury.

Do not install the productwhere it will be exposed tosea wind (salt spray) directly.

• It may cause corrosion on theproduct. Corrosion, particularly onthe condenser and evaporator fins,could cause product malfunction orinefficient operation.

Do not expose the skin directly to cool air forlong periods of time. (Don't sit in the draft.)

• This could harm to your health.

Do not use the product for special purposes,such as preserving foods, works of art, etc. Itis a consumer air conditioner, not a precisionrefrigeration system.

• There is risk of damage or loss of property.

Operational

Wax Thinner

Page 10: Multi Type Air Conditioner - SERVICE MANUAL

10 Multi type Air Conditioner

Safety Precautions

Do not step on or put anytingon the product. (outdoorunits)

• There is risk of personal injury andfailure of product.

Always insert the filter secure-ly. Clean the filter every twoweeks or more often if neces-sary.

• A dirty filter reduces the efficiencyof the air conditioner and couldcause product malfunction or dam-age.

Do not insert hands or otherobjects through the air inlet oroutlet while the product isoperated.

• There are sharp and moving partsthat could cause personal injury.

Do not drink the water drainedfrom the product.

• It is not sanitary and could causeserious health issues.

Use a firm stool or ladderwhen cleaning or maintainingthe product.

• Be careful and avoid personalinjury.

Replace the all batteries in theremote control with new onesof the same type. Do not mixold and new batteries or dif-ferent types of batteries.

• There is risk of fire or explosion

Do not recharge or disassemble the batteries.Do not dispose of batteries in a fire.

• They may burn or explode.

If the liquid from the batteries gets onto yourskin or clothes, wash it well with clean water.Do not use the remote if the batteries haveleaked.

• The chemicals in batteries could cause burns or otherhealth hazards.

Page 11: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 11

Dimensions

Dimensions

Indoor Unit

1. Split Type Indoor 2. Art Cool Type Indoor Unit

Pipe Hole

Fix Hole

Hanger Hole

H

W D

Installation plate

D

H

W

W mm 840 895 570

H mm 270 282 568

D mm 153 165 129

Model

Dimension

Split Type ARTCOOL Type

S4 SE

9 kBtu/h 12 kBtu/h 9 kBtu/h 12 kBtu/h

SP3

Page 12: Multi Type Air Conditioner - SERVICE MANUAL

12 Multi type Air Conditioner

Outdoor Unit

L6L7 L8L9

L4

H

L5W

D L1

L3

L2

L10

L11L

11L1

1L1

1L1

1

Gas side3-way valve

Liquid side2-way valve

Dimensions

UE2 36kMODEL

DIM

W mm 870

H mm 1038

D mm 320

L1 mm 360

L2 mm 340

L3 mm 25

L4 mm 1035

L5 mm 25

L6 mm 546

L7 mm 160

L8 mm 160

L9 mm 44

L10 mm 64.5

L11 mm 50

Page 13: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 13

Product Specifications

Product Specifications Indoor Unit

Nominal Cooling Capacity kcal/h(W)Btu/h

Nominal Heating Capacity kcal/h(W)Btu/h

Air Circulation H/M/L CMM(CFM)Setting temperature range(cool/heat) °CFan motor Output W

ModelInput VRunning Current A

Fan TypeNo. Used / Diameter EA/inch(mm)

Noise Level (Sound Press,1m) H/M/L dBATemperature controllerCoil Tube Size (OD) inch(mm)

Fins per inchNo. of Rows & Column

Dehumidification Rate l/hDimensions (W*H*D) inch(mm)Net Weight kg(lbs)Piping Connection Liquid inch(mm)

Gas inch(mm)Drain hose (ID Ø) mm

Packing Dimension (W*H*D) inch(mm)Stuffing Quantity With(Without) S/Parts 20/40ft(hi-c)

Wall Mounted

AMNC093D4L0(LMI090CP) AMNH093DL0(LMI090HP) AMNC123DEL0(LMI120CP) AMNH123DEL0(LMI120HP)

Indoor Unit Type

Model

Note : 1. See the page "Combination Table"2. Due to our policy of innovation some specifications may be changed without notification.

2,267(2,637) 2,267(2,637) 3,023(3,516) 3,023(3,516)9,000 9,000 12,000 12,000

- 2,267(2,637) - 3,023(3,516)- 9,000 - 12,000

8.2(289) 8.2(289) 9.4(332) 9.4(332)18~30 16~30 18~30 16~30

15 15 15 15DL-88430LGIF DL-88430LGIF DL-88430LGIF DL-88430LGIF

DC36 DC36 DC36 DC360.15 0.15 0.15 0.15

Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan1/3.74(95) 1/3.74(95) 1/3.74(95) 1/3.74(95)31 / 29 / 22 31 / 29 / 22 36 / 32 / 29 36 / 32 / 29Thermistor Thermistor Thermistor Thermistor0.197(5.0) 0.197(5.0) 0.197(5.0) 0.197(5.0)

20 20 18 182R,15C 2R,15C 2R,15C 2R,15C

- 1.1 - 1.233.0*10.6*6.0(840*270*153) 33.0*10.6*6.0(840*270*153) 35.2*11.1*6.5(895*282*165) 35.2*11.1*6.5(895*282*165)

7(15.4) 7(15.4) 9.5(20.9) 9.5(20.9)1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)

20 20 20 2035.7*13.1*8.8(906*332*223) 35.7*13.1*8.8(906*332*223) 38.3*9.1*14.6(973*231*372) 38.3*9.1*14.6(973*231*372)

440/910 (1091) 440/910 (1091) 353/719 (792) 353/719 (792)

2,267(2,637) 2,267(2,637) 3,023(3,516) 3,023(3,516)9,000 9,000 12,000 12,000

- 2,267(2,637) - 3,023(3,516)- 9,000 - 12,000

7.5(264) 7.5(264) 8.5(300) 8.5(300)18~30 16~30 18~30 16~30

24 24 24 24DL-89812LGIB DL-89812LGIB DL-89812LGIB DL-89812LGIB

DC36 DC36 DC36 DC361.5 1.5 1.5 1.5

Turbo Fan Turbo Fan Turbo Fan Turbo Fan1/24.32(617.7) 1/24.32(617.7) 1/24.32(617.7) 1/24.32(617.7)

37 / 31 / 27 37 / 31 / 27 43 / 39 / 31 43 / 39 / 31Thermistor Thermistor Thermistor Thermistor0.197(5.0) 0.197(5.0) 0.197(5.0) 0.197(5.0)

20 20 20 202R,20C 2R,20C 2R,20C 2R,20C

- 1.1 - 1.422.4*22.4*5.1(570*568*129) 22.4*22.4*5.1(570*568*129) 22.4*22.4*5.1(570*568*129) 22.4*22.4*5.1(570*568*129)

9(19.84) 9(19.84) 9(19.84) 9(19.84)1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)

20 20 20 2026.2*25.7*9.1(665*653*231) 26.2*25.7*9.1(665*653*231) 26.2*25.7*9.1(665*653*231) 26.2*25.7*9.1(665*653*231)

237/534(239/539) 237/534(239/539) 237/534(239/539) 237/534(239/539)

Nominal Cooling Capacity kcal/h(W)Btu/h

Nominal Heating Capacity kcal/h(W)Btu/h

Air Circulation H/M/L CMM(CFM)Setting temperature range(cool/heat) °CFan motor Output W

ModelNo. of PolesInput VRunning Current A

Fan TypeNo. Used / Diameter EA/inch(mm)

Noise Level (Sound Press,1m) H/M/L dBATemperature controllerCoil Tube Size (OD) inch(mm)

Fins per inchNo. of Rows & Column

Dehumidification Rate l/hDimensions (W*H*D) inch(mm)Net Weight kg(lbs)Piping Connection Liquid inch(mm)

Gas inch(mm)Drain hose (ID Ø) mm

Packing Dimension (W*H*D) inch(mm)Stuffing Quantity With(Without) S/Parts 20/40ft(hi-c)

Artcool

AMNC093APM0(LMA090CP) AMNH093APM0(LMA090HP) AMNC123APM0(LMA120CP) AMNH123APM0(LMA120HP)

Indoor Unit Type

Model

Page 14: Multi Type Air Conditioner - SERVICE MANUAL

14 Multi type Air Conditioner

Outdoor Unit - Multiple piping models

Product Specifications

Notes: 1. Capacities are based on the following conditions:Cooling: -Indoor Temperature 26.7°C(80.1°F)DB/19.4°C66.9°F)WB

-Outdoor Temperature 35°C(95°F)DB/23.9°C(75°F)WB-Interconnecting Piping Length 7.5m-Level Difference of Zero.

Heating: -Indoor Temperature 21.1°C(70°F)DB/15.6°C(60.1°F)WB-Outdoor Temperature 8.3°C(46.94°F)DB/6.1°C(42.98°F)WB-Interconnecting Piping Length 7.5m-Level Difference of Zero.

2. Capacities are Net Capacities.3. : See the page "Combination Table"4. Due to our policy of innovation some specifications may be changed without notification.

ModelCooling Capacity Btu/hr

Wkcal/hr

Heating Capacity Btu/hrW

kcal/hrInput Cooling W

Heating WRunning Current (208/230V) Cooling A

Heating APower Supply Ø,V,HzMax. Number of Connectable Indoor UnitsCompressor Type(Constant) Model

Motor TypeQuantity EaMotor Input WOil Charge ccOil TypeCapacitor µF/VacO.L.P Type(model name)

Compressor Type(Constant) Model

Motor TypeQuantity EaMotor Input WOil Charge ccOil TypeCapacitor µF/VacO.L.P Type(model name)

Refrigerant charge Charge g(oz)TypeControl

Coil Tube Size (OD) inch(mm)Fins per inchNo. of Rows & Column/No.

Fan motor ModelOutput WCapacitor µF/Vac

Fan TypeNo. Used / Diameter EA/inch(mm)Discharge Side / Top

Air Circulation Outdoor CMM(CFM)Noise Level(H/L) at 230V Sound Press,1m dB(A) 1DefrostingSVC Valve Liquid inch(mm)

GasDimensions W*H*D inch(mm)Net Weight Outdoor kg(lbs)Max. Interunit Piping Length Total of Each Room m

For One Room mMax. Installation Indoor Unit~Outdoor Unit mHeight Difference Indoor Unit~Indoor Unit mPacking Dimension W*H*D inch(mm)Testing CombinationsStuffing Quantity 20/40ft

9,000~36,000 9,000~36,000 9,000~24,000 9,000~24,0002637~10,550 2637~10,550 2637~7033 2637~70332267~9071 2267~9071 2267~6037 2267~6037

- 9,000~36,000 - 9,000~24,000- 2637~10,550 - 2637~7033- 2267~9071 - 2267~6037

1320~3680 1320~3680 1170~2390 1170~2390- 1410~3340 - 1220~2440

5.9~16.6 5.9~16.6 7.7~10.1 7.7~10.1- 6.3~15.0 - 7.4~9.8

1,208/230,60 1,208/230,60 1,208/230,60 1,208/230,603 3 2 2

Rotary Rotary Rotary RotaryGK141K GK141K GK094K GK094K

2 Pole Induction(PSC) 2 Pole Induction(PSC) Hermetic Hermetic1 1 1 1

1430 1430 955 955350Å10 350Å10 330±10 330±10 FVC68D FVC68D FVC68D FVC68D 35 / 370 35 / 370 30 / 370 30 / 370

External Type External Type External Type(MRA98996-12026) External Type(MRA98996-12026)Rotary Rotary Rotary Rotary

GJ230K GJ230K GK141K GK141K2 Pole Induction(PSC) 2 Pole Induction(PSC) Hermetic Hermetic

1 1 1 12370 2370 1430 1,430

700±10 7000±10 350±10 350±10 FVC68D FVC68D FVE FVE50 / 400 50 / 400 35 / 370 35 / 370

Internal Type Internal Type External Type(MRA12105-12026) External Type(MRA12105-12026)2400 2400 1600 1600

R410A R410A R410A R410AL.E.V L.E.V L.E.V L.E.V

0.276(7.0) 0.276(7.0) 0.276(7.0) 0.276(7.0)18 18 18 18

2R,48C 2R,48C 2R,36C 2R,36CARC286B01 * 2 ARC286B01 * 2 IC-1640LG GE IC-1640LG GE

102 102 90 902/370 2/370 6/370 6/370

Propeller Propeller Propeller Propeller2 / 15.7(400) 2 / 15.7(400) 1 / 460 1 / 460

Side Side Side Side63(2225) 63(2225) 53(1872) 53(1872)

51 51 54 54- - - Invertion Cycle

1/4 (6..35) * 3EA 1/4 (6..35) * 3EA 1/4 (6.35) * 2EA 1/4 (6.35) * 2EA3/8 (9.52) * 3EA 3/8 (9.52) * 3EA 3/8 (9.52) * 2EA 3/8 (9.52) * 2EA

34.3*41.7*12.6 (870*1060*320) 34.3*41.7*12.6 (870*1060*320) 34.3*31.5*12.6 (870*800*320) 34.3*31.5*12.6 (870*800*320)80(176) 80(176) 69(152) 69(152)

45 45 30 3015 15 15 157.5 7.5 7.5 7.57.5 7.5 7.5 7.5

41.1*44.9*17.3 (1045*1140*440) 41.1*44.9*17.3 (1045*1140*440) 40.2*34.3*17.3 (1020*870*440) 40.2*34.3*17.3 (1020*870*440)- - SE 12K +SE 12K SE 12K +SE 12K

51/111 51/111 54/114 54/114

A3UC363FA0(LMO360C) A3UH363FA0(LMO360H) A2UC243FA0(LMO240C) A2UH243FA0(LMO240H)

Page 15: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 15

Installation

Installation

Type "A" screw and plastic anchor

Type "B" screw Remote Control Holder

Installation plate

Figure FigureName

Screw driver

Electric Drill

Measuring Tape, Knife

Hole Core Drill

Spanner

Torque wrench

Ohmmeter

Hexagonal wrench

Ammeter

Gas Leak Detector

Thermometer, Level

Flaring Tool Set

Name

Installation Parts

Installation Tools

Read carefully, and then follow step by step.

Page 16: Multi Type Air Conditioner - SERVICE MANUAL

Installation

16 Multi type Air Conditioner

Indoor unit1. Do not have any heat or steam near the unit.

2. Select a place where there are no obstacles in frontof the unit.

3. Make sure that condensation drainage can be conve-niently routed away.

4. Do not install near a doorway.

5. Ensure the spaces indicated by arrows from the wall,ceiling, fence or other obstacles.

6. Use a stud finder to locate studs to prevent unneces-sary damage to the wall.

Outdoor unit1. If an awning is built over the unit to prevent direct

sunlight or rain exposure, make sure that heat radia-tion from the condenser is not restricted.

2. Ensure that the spaces indicated by arrows aroundfront, back and side of the unit.

3. Do not place animals and plants in the path of thewarm air.

4. Take the air conditioner weight into account andselect a place where noise and vibration are mini-mum.

5. Select a place so that the warm air and sound fromthe air conditioner do not disturb neighbors.

Rooftop Installations:If the outdoor unit is installed on a roof structure, besure to level the unit. Ensure the roof structure andanchoring method are adequate for the unit location.Consult local codes regarding rooftop mounting.

Select the best location

More than 5cm(2.0 inch)

More than 5cm(2.0 inch)

More than 2.3m(90.6 inch)

More than 5cm(2.0 inch)

More than 10cm

More than 50cm

More than 2m

More than 50cm

more than 70cm(27.6 inch)

more than 30cm(11.8 inch)

more than 30cm(11.8 inch)

CAUTION: Install the indoor uniton the wall where the height fromthe floors more than 2.3m(7.5ft).

Page 17: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 17

Installation

Piping length and elevation

h2

h2

h1

A

B

C

h1

h1

CAUTION: Capacity is based on standard length and maximum allowance length is on thebasis of reliability. Oil trap should be installed every 5~7 meters (16.4~23.0ft).

Multi Piping Type

36k 45m(150ft) 15m(50ft) 3m(10ft) 7.5m(25ft) 7.5m(25ft)

Capacity(Btu/h)Max total length of

all pipes(A+B/A+B+C)

Max length of eachpipe (A/B/C)

Min length of eachpipe (A/B/C)

Max Elevationbetween each

indoor unit and out-door unit (h1)

Max elevationbetween indoor

units (h2)

9K 3/8" 1/4" 7.5m(25ft) 20g/m(0.32oz/ft)

12K 3/8" 1/4" 7.5m(25ft) 20g/m(0.32oz/ft)

Gas Liquid Standard Length Additional RefrigerantIndoor Capacity

(Btu/h)

Pipe Size

Page 18: Multi Type Air Conditioner - SERVICE MANUAL

18 Multi type Air Conditioner

Installation

The wall you select should be strong and solid enough toprevent vibration

1. Mount the installation plate on the wall with type "A" screws. If mounting the unit on a concrete wall,use anchor bolts.

• Mount the installation plate horizontally by aligning thecenterline using a level.

2. Measure the wall and mark the centerline. It is alsoimportant to use caution concerning the location of theinstallation plate-routing of the wiring to power outlets isthrough the walls typically. Drilling the hole through thewall for piping connections must be done safely.

Fixing Installation Plate(Standard Type)

Installation Plate

Type "A" screw

ChassisHook

Installation plate

Left rear piping Right rear pipingØ70mm Ø70mm

D B

ACA B C D

S4 50 105 59 105

SE 65 110 85 110

CHASSIS(Grade)

Distance (mm)

Page 19: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 19

Installation

Preparing work for Installation (Artcool Type Only)Open panel front1. First, push the front panel backward and lift it up to remove the two screws.

2. The moment of lifting the both lower parts of panel front, you can hear sound this panel came out, In this time panel front isseparated

3. After pull down this panel a bit, and separate connecting wire with product.

Remove cover pipe and cover side1. Remove two screws(for fixing cover pipe)2. Pull up the cover side of desired connecting direction, then cover

side is separated.3. In case of connecting direction is left or right, path through the

hole of cover side.

CAUTION: After removing the pipe hole, cut theburr for safety.

When connecting pipe path through rearwall, don’t remove the hole.

NOTICE

Drain hose junction1. Remove the rubber stopple of desired direction of

drainage.

2. As the following picture, Insert drain hose in thehandle of drain pan, and join drain hose and con-necting hose.

Panel Front Connector

Pipe hole

rubber cap

Only onedesiring direction

Connectingpart

Adhesive

Drainhose

Page 20: Multi Type Air Conditioner - SERVICE MANUAL

20 Multi type Air Conditioner

Installation

Sticking the installation guide map and fixing Indoor unit

Drill a hole in the wall

• Drill the piping hole with a ø50mm hole core drill. Drillthe piping hole at either the right or the left with the holeslightly slanted to the outdoor side.

Plastic anchors

INSTALLATION GUIDE MAP

10mmINSTALLATION GU

INSTAIIATION GUIDE MAP

INSTALLATION GUIDE MAP

1. Put an Installation Guide Map on the desired surface.

2. Make a hole with diameter of 6mm and depth of 30-35mm when piercing a screw point.

3. Drive the fore plastic anchors into drilled points.

4. Hang the hole of product at the upper screws. (In this time, Remove the map) (Falling attention)

5. Check the fixed product with light power.

6. Look at suited horizon by horizontal meter on the horizontal setting line, and Fix lightly the map by adhesive tape.

7. Drill the piercing part for connecting pipe as diameter 50mm. (In case of piercing rear surface)

Refer to No. 5 on this page when making a hole in the wall.

8. First, Drive the two points of the upper parts by screws. (Leave 10mm for hanging product)

9. Drive the lower parts after facing the hole of product with plastic anchors, and fix completely the upper screws.

In case of nothing wrong in the matter,connect the pipe and the wire. (Installation manual reference)

Horizontality

INSTALLATION GUIDE MAP

Plastic anchors

INSTALLATION GUIDE MAP

Hanger hole(Rear side of

product)5-

7mm

(0.2

~0.

3")

Indoor

WALL

Outdoor

Page 21: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 21

Flaring Work and Connection of Piping

Flaring workMain cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following procedure.

Cut the pipes and the cable.1. Use the piping kit accessory or the pipes purchased locally.

2. Measure the distance between the indoor and the outdoor unit.

3. Cut the pipes a little longer than measured distance.

4. Cut the cable 1.5m (5.0ft) longer than the pipe length.

Burrs removal1. Completely remove all burrs from the cut cross section of

pipe/tube.

2. Put the end of the copper tube/pipe in a downward directionas you remove burrs in order to avoid dropping burrs into thetubing.

Putting nut on• Remove flare nuts attached to indoor and outdoor unit, then

put them on pipe/tube having completed burr removal.(not possible to put them on after flaring work)

Flaring work• Carry out flaring work using flaring tool as shown below.• Firmly hold copper pipe in a die in the dimension shown in the

table above.

Copperpipe 90° Slanted Uneven Rough

Pipe

Reamer

Point down

Flare nut

Copper tube

mm inch mmØ6.35 1/4 0~0.5Ø9.52 3/8 0~0.5

Outside diameter A

Bar

Copper pipe

Clamp handleRed arrow mark

Cone

Yoke

Handle

Bar"A"

Flaring Work and Connection of Piping

Page 22: Multi Type Air Conditioner - SERVICE MANUAL

22 Multi type Air Conditioner

Flaring Work and Connection of Piping

Check1. Compare the flared work with the figure by.

2. If a flared section is defective, cut it off and do flaring workagain.

Indoor1. Prepare the indoor unit's piping and drain hose for installation through the wall.

2. Remove the plastic tubing retainer(see the illustration by)and pull the tubing and drain hose away from chassis.

3. Replace only the plastic tubing holder 1, not the holder 2 inthe original position.

1. Route the indoor tubing and the drain hose in the directionof rear right.

2. Insert the connecting cable into the indoor unit from the out-door unit through the piping hole.• Do not connect the cable to the indoor unit.• Make a small loop with the cable for easy connection later.

3. Tape the tubing, drain hose, and the connecting cable. Besure that the drain hose is located at the lowest side of thebundle. Locating at the uper side can cause drain pan tooverflow inside the unit.

If the drain hose is routed inside the room, insulate the hosewith an insulation material* so that dripping from "sweat-ing"(condensation) will not damage furniture or floors.*Foamed polyethylene or equivalent is recommended.

Inclined

Inside is shiny without scratches

Smooth all round

Even lengthall round

Surfacedamaged

Cracked Uneventhickness

= Improper flaring =

Connecting the Piping

For right rear piping

Drain hose

Drain hose

Connecting pipe

Connecting cable

Tape

Drain hose

Connectingcable

Gas side piping

Liquid side pipingDrain hose

Loop

Page 23: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 23

Flaring Work and Connection of Piping

4. Indoor unit installationHook the indoor unit onto the upper portion of the installa-tion plate.(Engage the two hooks of the rear top of theindoor unit with the upper edge of the installation plate.)Ensure that the hooks are properly seated on the installa-tion plate by moving it left and right.

Press the lower left and right sides of the unit against theinstallation plate until the hooks engage into theirslots(clicking sound).

Connecting the piping to the indoor unit and drain hoseto drain pipe.

1. Align the center of the pipes and sufficiently tighten theflare nut by hand.

2. Tighten the flare nut with a wrench.

3. When extending the drain hose at the indoor unit, installthe drain pipe.

Wrap the insulation material around the connecting por-tion.

1. Overlap the connection pipe insulation material and theindoor unit pipe insulation material. Bind them togetherwith vinyl tape so that there may be no gap.

2. Wrap the area which accommodates the rear piping hous-ing section with vinyl tape.

3. Bundle the piping and drain hose together by wrappingthem with vinyl tape for enough to cover where they fit intothe rear piping housing section.

Drain hose

Connectingcable

Indoor unit tubing Flare nut Pipes

Wrench

Indoor unit tubing

Open-end wrench (fixed)

Connection pipe

Flare nut

Vinyl tape(narrow)Adhesive

Drain pipe

Indoor unit drain hose

Plastic bands Insulation material

Vinyl tape(narrow)

Connection pipe

Connecting cableVinyl tape (wide) Wrap with vinyl tape

Indoor unit pipe

Pipe

Wrap with vinyl tape

Drain hose

Pipe

Vinyl tape(wide)

mm inch kg.mØ6.35 1/4 1.8Ø9.52 3/8 4.2

Outside diameter Torque

Page 24: Multi Type Air Conditioner - SERVICE MANUAL

24 Multi type Air Conditioner

Flaring Work and Connection of Piping

1. Route the indoor tubing and the drain hose to the requiredpiping hole position.

2. Insert the piping, drain hose, and the connecting cable intothe piping hole.

3. Insert the connecting cable into the indoor unit.• Don't connect the cable to the indoor unit.• Make a small loop with the cable for easy connection

later.

4. Tape the drain hose and the connecting cables.

5. Indoor unit installation• Hang the indoor unit from the hooks at the top of the

installation plate.• Insert the spacer etc. between the indoor unit and the

installation plate and separate the bottom of the indoorunit from the wall.

Connecting the piping to the indoor unit and the drainhose to drain pipe.1. Align the center of the pipes and sufficiently tighten the

flare nut by hand.

2. Tighten the flare nut with a wrench.

3. When extending the drain hose at the indoor unit, installthe drain pipe.

For left rear piping

Drain pipe

Connectingcable

1 2

Installation plate

SpacerIndoor unit

8cm

Indoor unit tubing Flare nut Pipes

Wrench

Indoor unit tubing

Connection pipe

Flare nut

Open-end wrench (fixed)

Vinyl tapeAdhesive

Drain hose

Indoor unit drain hose

(narrow)

mm inch kg.mØ6.35 1/4 1.8Ø9.52 3/8 4.2

Outside diameter Torque

Page 25: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 25

Flaring Work and Connection of Piping

Wrap the insulation material around the connecting por-tion.1. Overlap the connection pipe heat insulation and the indoor

unit pipe heat insulation material. Bind them together withvinyl tape so that there may be no gap.

2. Wrap the area which accommodates the rear piping hous-ing section with vinyl tape.

3. Bundle the piping and drain hose together by wrappingthem with cloth tape over the range within which they fitinto the rear piping housing section.

Reroute the pipings and the drain hose across the backof the chassis.

Indoor unit installation 1. Remove the spacer.

2. Ensure that the hooks are properly seated on the installa-tion plate by moving it left and right.

3. Press the lower left and right sides of the unit against theinstallation plate until the hooks engage into theirslots(clicking sound).

Plastic bands Insulation material

Vinyl tape(narrow)

Connectionpipe

Connecting cable

Indoor unit piping

Pipe

Vinyl tape(wide)

Wrap with vinyl tape

Drain hoseVinyl tape(narrow)

Pipe

Wrap with vinyl tape(wide)

Piping forpassage throughpiping hole

Drain hose

Connectingcable

Page 26: Multi Type Air Conditioner - SERVICE MANUAL

26 Multi type Air Conditioner

Flaring Work and Connection of Piping

Panel Assembly(Art Cool Type only)1. First, Check the side cover assembly exactly, Fix

power cord in the bottom groove of cover sideleft.

2. Assemble connecting lead wire with controllerand first fix the upper part of panel front, thenmatch the lower part of panel front

3. Drive two screws.

Panel FrontConnector

Page 27: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 27

Installation Information. For left piping. Follow the instruction below.

Good case• Press on the upper side of clamp and unfold the tubing to downward slowly.

Bad case• Following bending type from right to left may cause damage to the tubing.

Flaring Work and Connection of Piping

Page 28: Multi Type Air Conditioner - SERVICE MANUAL

28 Multi type Air Conditioner

Flaring Work and Connection of Piping

Remove the battery cover from the remote con-troller.• Slide the cover according to the arrow direction.

Insert the two batteries.• Be sure that the (+) and (-) directions are correct.• Be sure that both batteries are new.

Re-attach the cover.• Slide it back into position.

REMOTE CONTROL PREPARATION(OPTIONAL)

HOW TO MOUNT ONTO A WALL

HOW TO INSERT BATTERIES

• Do not use rechargeable batteries,such batteries differ from standard drycells in shape, dimensions, and per-formance.

• Romove the batteries from the remotecontroller if the air conditioner is notgoing to be used for some long time.

HOW TO INSERT BATTERIES

Page 29: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 29

Flaring Work and Connection of Piping

OutdoorAlign the center of the pipings and sufficiently tighten the flarenut by hand.

Finally, tighten the flare nut with torque wrench until thewrench clicks.

• When tightening the flare nut with torque wrench, ensurethe direction for tightening follows the arrow on the wrench.

Outdoor unit

Torque wrench

Liquid side pipingB-UNIT

C-UNIT

A-UNITGas side piping

Outside diameter Torquemm inch kg.m

Ø6.35 1/4 1.8Ø9.52 3/8 4.2

Page 30: Multi Type Air Conditioner - SERVICE MANUAL

30 Multi type Air Conditioner

Connecting the Cable between Indoor Unit and Outdoor Unit

Connect the cable to the indoor unit by connecting the wires to the terminals on the control board individuallyaccording to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No. arethe same as those of the indoor unit.)The earth wire should be longer than the common wires.The circuit diagram is not subject to change without notice.When installing, refer to the electrical diagram behind the front panel of Indoor Unit. The wiring for the outdoor unit can be found on the inside of the Outdoor Unit control cover.

Connect the cable to the Indoor unit.

RECOMMAND: • The circuit diagram is not subject to change without notice. • Be sure to connect wires according to the wiring diagram.• Connect the wires firmly, so that not to be pulled out easily.• Connect the wires according to color codes by referring to the wiring diagram.

RECOMMAND: Provide a circuit breakerbetween power source and the outdoorunit as shown below.

RECOMMAND: The power cord connected to the outdoor unit should be complied with the followingspecifications (ETL recognized and CSA certified).

The power connecting cable connected to the indoor and outdoor unit should be complied with thefollowing specifications (ETL recognized and CSA certified).

Air Conditioner

Main power source

Circuit BreakerUse a circuit breakeror time delay fuse.

GN/YL

20mm

Line voltage (208~230V)

AWG14

GN/YL

20mm

AWG18

Low voltage (below 40V)

RECOMMAND: When using the separate wire as the power cord, please fix the separate wire into thecontrol box panel by using tie wrap as the fixture.

Connecting the Cable between Indoor Unit and Outdoor Unit

Page 31: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 31

Connect the cable to the Outdoor unit.1. Remove the cover control from the unit by loosening the

screw.Connect the wires to the terminals on the control boardindividually as the following.

2. Secure the cable onto the control board with the holder(clamper).

3. Refix the cover control to the original position with thescrew.

: 1. Separately wire the high and low voltage line.

2. Use heat-proof electrical wiring capable of withstanding temperature up to 75°C(167°F).

3. Use outdoor and waterproof connection cable rated more than 300V for the connection between indoor and outdoor unit.(For example, Type SJO-WA)

WARNING:

• Be sure to comply with local codes while running the wire from the indoor unit to the outdoor unit(size ofwire and wiring method, etc).

• Every wire must be connected firmly.• No wire should be allowed to touch refrigerant tubing, the compressor or any moving parts.

NOTICE

Outdoor unit

Over 5mm

Holder forpower supply

cord

Connectingcable

Cover control

Terminal block

Power supplycable

Connecting cable(Low voltage)

A-UNIT

4321

B-UNIT

4321

L N

Power Source208/230V AC(High voltage)

36k Outdoor side

Indoor B-UNIT

C-UNIT

4321

Indoor C-UNIT

Connecting cable(Low voltage)Connecting cable(Low voltage)Connecting cable(Low voltage)

Indoor A-UNIT

Terminal BLOCK

4321

Terminal BLOCK

4321

Terminal BLOCK

4321

Connecting the Cable between Indoor Unit and Outdoor Unit

Page 32: Multi Type Air Conditioner - SERVICE MANUAL

32 Multi type Air Conditioner

(1) Remove two-caps on the conduit panel.(2) Make a hole appropriate for the passage of connection cable

through on cap by tool.(for low voltage line)

(3) Pass the connecting cable through the hole.(4) Properly connect the cable on the terminal block.(5) Fix the connection cable with cord clamp provided on the unit

not to have strain at the terminal when the connection cable ispulled outside up to a 35 pound weight.

(6) Wind the vinyl tape round the connecting cable for sealingbetween the surface of the connection cable and cap.

(7)Finally, Fix the cap to the conduit panel.

WARNING: Loose wiring may cause the termi-nal to overheat or result in unit malfunction. Afire hazard may also exist. Therefore, be sureall wiring is tightly connected.

When connecting each power wire to the corresponding terminal,follow instructions "How to connect wiring to the terminals" andfasten the wire tightly with the fixing screw of the terminal plate.

How to connect wiring to the terminals For strand wiring(1) Cut the wire end with a wire cutter or wire-cutting pliers,

then strip the insulation to expose the strand wiring about10mm(3/8").

(2) Using a screwdriver, remove the terminal screw(s) on theterminal plate.

(3) Using a round terminal fastener or pliers, securely clampeach stripped wire end with a round terminal.

(4) Position the round terminal wire, and replace and tightenthe terminal screw using a screwdriver.

Connection method of the connecting cable(Example)

G

Terminalblock

Lock nut

Power supply line(1ø, 230/208V)

Conduit panel

Cap(Reuse)

Cord clamp

Hole(for low voltage line)Cap(Remove)Taping(for sealing)

Low voltage line(connecting cable)

High voltage

Low voltage

Str

ip 1

0mm

(3/8

")

Roundterminal

Connecting cable

Loosening theterminal blockscrew

Fastening the wire tightly

Strand wire

Connecting the Cable between Indoor Unit and Outdoor Unit

Page 33: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 33

Connect the cable to the indoor unit

CAUTION: Provide a circuit breaker between power source and the unit as shownbelow.

AirConditioner Circuit Breaker

Use a circuitbreaker or timedelay fuse.

Main power source

Model

36k 1Ø, 230/208V 40A

Power source Fuse or breakerCapacity

1. Connect the wires to the terminals on the control boardindividually according to the outdoor unit connection.

• Ensure that the color of the wires of outdoor unit and theterminal No. are the same as those of indoor unit respec-tively.

2. Attach the Grille onto the cabinet.

• Grasp the lower left and right side of the Grille andengage four tabs on the top inside edge of the chassis.

• Press the Grille toward the chassis until it will be back intoplace.

Connecting cable

Connecting the Cable between Indoor Unit and Outdoor Unit

Page 34: Multi Type Air Conditioner - SERVICE MANUAL

34 Multi type Air Conditioner

Checking the Drainage, Forming the Pipings and Long Pipe Setting

Checking the drainage

To check the drainage.1. Pour a glass of water on the evaporator.

2. Ensure the water flows through the drain hose of theindoor unit without any leakage and goes out the drain exit.

Drain piping1. The drain hose should point downward for easy drain flow.

2. Do not make drain piping.

Downward slope

Do not raiseAccumulateddrain water

Tip of drain hose dipped in water

Air

WavingWaterleakage

Waterleakage Ditch

Less than 50mm gap

Waterleakage

Checking the Drainage, Forming the Pipings and Long Pipe Setting

Page 35: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 35

Checking the Drainage, Forming the Pipings and Long Pipe Setting

Forming the piping

Form the piping by wrapping the con-necting portion of the indoor unit withinsulation material and secure it withtwo kinds of vinyl tape.• If you want to connect an additional drain hose, the end

of the drain outlet should be routed above the ground.Secure the drain hose appropriately.

In cases where the outdoor unit isinstalled below the indoor unit performthe following.1. Tape the piping, drain hose and connecting cable from

down to up.2. Secure the tapped piping along the exterior wall using

saddle or equivalent.

In cases where the Outdoor unit isinstalled above the Indoor unit performthe following.1. Tape the piping and connecting cable from down to up.2. Secure the taped piping along the exterior wall. Form a

trap to prevent water entering the room.3. Fix the piping onto the wall by saddle or equivalent.

Seal a small opening around the pipings with gum type sealer.

Trap

Trap

• Trap is required to prevent water from enteringinto electrical parts.

Plasticband

Taping

Drain hose

Pipings

Connectingcable

Power supplycord

Seal a small opening around the pipings with gum type sealer.

Page 36: Multi Type Air Conditioner - SERVICE MANUAL

36 Multi type Air Conditioner

Air Purging and Evacuation

Air and moisture remaining in the refrigerant system have undesirable effects as indicated below.1. Pressure in the system rises.2. Operating current rises.3. Cooling(or heating) efficiency drops.4. Moisture in the refrigerant circuit may freeze and block capillary tubing.5. Water may lead to corrosion of parts in the refrigeration system.Therefore, the indoor/outdoor unit and connecting tube must be checked for leak tight, and vacuumed to remove incondensi-ble gas and moisture in the system.

Preparation• Check that each tube(both liquid and gas side tubes) between

the indoor and outdoor units have been properly connected andall wiring for the test run has been completed. Remove the ser-vice valve caps from both the gas and the liquid side on the out-door unit. Check that both the liquid and the gas side servicevalves on the outdoor unit are kept closed at this stage.

Leakage test• Connect the manifold valve(with pressure gauges) and dry nitro-

gen gas cylinder to this service port with charge hoses.

CAUTION: Be sure to use a manifoldvalve for leak testing.

The high side manifold valve must alwaysbe kept closed.

• Pressurize the system to no more than 150 P.S.I.G. with drynitrogen gas and close the cylinder valve when the gaugereading reached 150 P.S.I.G. Next, test for leaks with liquidsoap.

CAUTION: To avoid nitrogen entering therefrigerant system in a liquid state, the top

of the cylinder must be higher than its bottomwhen you pressurize the system. Usually, thecylinder is used in a vertical standing position.

: Leakage test shoud be done for each indoorunit connection set, separately.

1. Do a leakage test of all joints of the tubing(both indoor andoutdoor) and both gas and liquid side service valves.Bubbles indicate a leak. Be sure to wipe off the soap with aclean cloth.

2. After the system is found to be free of leaks, relieve thenitrogen pressure by loosening the charge hose connectorat the nitrogen cylinder. When the system pressure isreduced to normal, disconnect the hose from the cylinder.

NOTICE

Checking method

Charge hose

Nitrogen gascylinder(in verticalstanding position)

Indoor unit

Outdoor unit

Lo Hi

Manifold valve

Pressure gauge

Air Purging and Evacuation

Page 37: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 37

Checking the Drainage, Forming the Pipings and Long Pipe Setting

1. Connect the charge hose end described in the precedingsteps to the vacuum pump to evacuate the tubing andindoor unit.Confirm the "Lo" knob of the manifold valve is open. Then,run the vacuum pump.The operation time for evacuation varies with tubing lengthand capacity of the pump. The following table shows thetime required for evacuation.

2. When the desired vacuum is reached, close the "Lo" knobof the manifold valve and stop the vacuum pump.

Finishing the job1. With a service valve wrench, turn the valve stem of liquid

side valve counter-clockwise to fully open the valve.

2. Turn the valve stem of gas side valve counter-clockwise tofully open the valve.

3. Loosen the charge hose connected to the gas side serviceport slightly to release the pressure, then remove the hose.

4. Replace the flare nut and its bonnet on the gas side ser-vice port and fasten the flare nut securely with anadjustable wrench. This process is very important to pre-vent leakage from the system.

5. Replace the valve caps at both gas and liquid side servicevalves and fasten them tight.

This completes air purging with a vacuum pump.

The air conditioner is now ready for test running.

: Repeat evacuation procedure for each indoorunit.

NOTICE

Required time for evacuation when 30 gal/h vacuumpump is used

10 min. or more 15 min. or more

If tubing length is lessthan 10m (33 ft)

If tubing length is longerthan 10m (33 ft)

Indoor unit

Outdoor unit

Lo Hi

Manifold valve

Vacuum pump

Pressure gauge

Open Close

Evacuation

Page 38: Multi Type Air Conditioner - SERVICE MANUAL

38 Multi type Air Conditioner

Charging

Each outdoor unit is factory charged (nameplate charge) for the evaporator as well as a 7.5m(25ft) line set for each indoorline. Any time total line set is used either shorter or longer then the nominal 22.5m(75ft: for tri-zone) line set length the refrigerantcharge has to be adjusted.

Whether the line set is made shorter or longer you must adjust the charge based on how many ft of tubing are either addedor removed based on 20g(0.22oz) of R-410A per meter(foot).

Example: A 80ft line set is used for tri - zone 5 additional ft X 0.22 ounces per foot= add 1.1 ounces of R-410A

Important:If you are ever uncertain of the unit charge, reclaim, evacuate and weigh in the correct charge using the unit nameplate chargeadjusting for line sets longer or shorter than 7.5m(25ft) for each indoor unit.

Charging

36k 45m(150ft) 15m(50ft) 3m(10ft) 7.5m(25ft) 7.5m(25ft) 20g/m(0.22oz/ft)

Capacity (Btu/h)Max total length

of all pipes(A+B+C)

Max length ofeach pipe(A/B/C)

Min length ofeach pipe(A/B/C)

Max Elevationbetween each indoorunit and outdoor unit

(h1)

Max elevationbetween indoor

units (h2)

AdditionalRefrigerant

Page 39: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 39

1. Check that all tubing and wiring have been properly con-nected.

2. Check that the gas and liquid side service valves arefully open.

1) Prepare remote controller

Remove the battery cover by pulling it according tothe arrow direction.Insert new batteries making sure that the (+) and (–)of battery are installed correctly.Reattach the cover by pushing it back into position.

NOTE:• Use 2 AAA(1.5volt) batteries. Do not use rechargeable

batteries.• Remove the batteries from the remote controller if the sys-

tem is not going to be used for a long time.

2) Precautions in test run

The initial power supply must provide at least 90% ofthe rated voltage.Otherwise, the air conditioner should not be operated.

For test run, carry out the cooling operation firstlyeven during heating season. If heating operation iscarried out firstly, it leads to the trouble of compres-sor. Then attention must be paid.

Carry out the test run more than 5 minutes withoutfail. (Test run will be cancelled 18 minutes later auto-matically)

The test run is started by pressing timer cancel buttonfive times continuously. (Room type)

To cancel the test run, press any button.

3) Settlement of outdoor unit

Anchor the outdoor unit with a bolt and nut(ø10mm)tightly and horizontally on a concrete or rigid mount.

When installing on the wall, roof or rooftop, anchor themounting base securely with a nail or wire assuming theinfluence of wind and earthquake.

In the case when the vibration of the unit is conveyed tothe hose, secure the unit with an anti-vibration rubber.

4) Evaluation of the performance

Operate unit for 15~20 minutes, then check the systemrefrigerant charge:1. Measure the pressure of the gas side service valve.2. Measure the temperature of the intake and discharge of

air.3. Ensure the difference between the intake temperature

and the discharge is more than 8°C(46°F) (Cooling) orreversely (Heating).

Bolt

Tubing connection

Discharge temperature

Discharge air

Intake temperature

Test Running

Split, Art Cool Type

Discharge temperature

Discharge air

Intake temperature

R-410A 35°C (95°F) 8.5~9.5kg/cm2G(120~135 P.S.I.G.)

Outside ambientTEMP.Refrigerant The pressure of the gas side

service valve.

Test Running

Page 40: Multi Type Air Conditioner - SERVICE MANUAL

40 Multi type Air Conditioner

Operation

1. MAIN UNIT FUNCTION • DISPLAYOperation Indicator

• On while in appliance operation, off while in appliance pause• Flashing while in disconnection or short in Thermistor (3 sec off / 0.5 sec on)

Sleep Timer Indicator• On while in sleep timer mode, off when sleep timer cancel or appliance operation pause

Timer Indicator• On while in timer mode (on/off), off when timer mode is completed or canceled

Defrost Indicator• Off except when hot start during heating mode operation or while in defrost control

Cooling Mode Operation• When the intake air temperature reaches 0.5°C(32.9°F) below the setting temp, the compressor and the outdoor

fan stop.• When it reaches 0.5°C(32.9°F) above the setting temp, they start to operate again.

Compressor ON Temp Setting Temp+0.5°C(32.9°F)Compressor OFF Temp Setting Temp-0.5°C(31.1°F)

• While in compressor running, operating with the airflow speed set by the remote control. While compressor isoff fan operates at low speed regardless of the setting.

Soft Dry Operation Mode• When the dehumidification operation input by the remote control is received, the intake air temperature is

detected and the setting temp is automatically set according to the intake air temperature.26°C(78.8°F) ≤ Intake Air Temp 25°C(77°F)24°C(75.2°F) ≤ Intake Intake Air Temp<26°C(78.8°F) Intake Air Temp-1°C(30.2°F)18°C(64.4°F) ≤ Intake Intake Air Temp<24°C(75.2°F) Intake Air Temp-0.5°C(31.1°F)Intake Air Temp<18°C(64.4°F) 18°C(64.4°F)

• While compressor off, the indoor fan repeats low airflow speed and stop.• While the intake air temp is between compressor on temp. and compressor off temp., 10-min dehumidification

operation and 4-min compressor off repeat.Compressor ON Temp. Setting Temp+0.5°C(32.9°F)Compressor OFF Temp. Setting Temp-0.5°C(31.1°F)

• In 10-min dehumidification operation, the indoor fan operates with the low airflow speed.

Heating Mode Operation• When the intake air temp reaches +3°(37.4°F)…above the setting temp, the compressor is turned off. When

below the setting temp, the compressor is turned on.Compressor ON Temp. Setting Temp.Compressor OFF Temp. Setting Temp.+3°C(37.4°F)

• While compressor on, the indoor fan is off when the indoor pipe temp. is below 20°C(68°F), when above27°C(80.6°F) , it operates with the low or setting speed. When the indoor pipe temp is between 20°C(68°F) and

Function of control

Operation

Page 41: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 41

Operation

27°C(80.6°F), it operates with Super-Low(while in sleep mode, with the medium airflow speed).• While compressor off, the indoor fan is off when the indoor pipe temp is below 33°C(91.4°F), when above

35°C(95°F) , it operates with the low airflow speed.• While in defrost control, the indoor is outdoor fans are turned off.

Defrost Control(Heating)• Defrost operation is controlled by timer and sensing temperature of outdoor pipe.• The first defrost starts only when the outdoor pipe temperature falls below -6°C(21.2°F) after 35 minutes

passed from starting of heating operation and more than 4 minutes operation of compressor.• Defrost ends after 12 minutes passed from starting of defrost operation when the outdoor pipe temperature

rises over 15°C(59°F) even before 12 minutes.• The second defrost starts only when the outdoor pipe temperature falls below -6°C(21.2°F) after 35 minutes

passed from ending of the first defrost and more than 4 minutes operation of compressor.

Fuzzy Operation• When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed since

the operation off, the operation mode is selected.• When determining the operation mode, the compressor, the outdoor fan, and the 4 way valve are off and only

the indoor fan is operated for 15 seconds. Then an operation mode is selected according to the intake airtemp at that moment as follows.24°C(75.2°F) ≤ Inatake Air Temp Fuzzy Operation for Cooling21°C(69.8°F) ≤ Inatake Air Temp<24°C(75.2°F) Fuzzy Operation for DehumidificationInatake Air Temp<21°C(69.8°F) Fuzzy Operation for Heating

• If any of the operation modes among cooling / dehumidification / heating mode operations is carried out for 10sec or longer before Fuzzy operation, the mode before Fuzzy operation is operated.

1) Fuzzy Operation for Cooling

• According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5°C(32.9°F) or morebelow the setting temp, the compressor is turned off. When 0.5°C(32.9°F) or more above the setting temp, thecompressor is turned on.Compressor ON Temp Setting Temp +0.5°C(32.9°F)Compressor OFF Temp Setting Temp + 0.5°C(32.9°F)

• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to theintake air temp at that time.26°C(78.8°F)≤ Intake Air Temp 25°C(77°F)24°C(75.2°F)≤ Intake Air Temp<26°C(78.8°F) Intake Air Temp + 1°C(33.8°F)22°C(71.6°F)≤ Intake Air Temp<24°C(75.2°F) Intake Air Temp + 0.5°C(32.9°F)18°C(64.4°F)≤ Intake Air Temp<22°C(71.6°F) Intake Air TempIntake Air Temp<18°C(64.4°F) 18°C(64.4°F)

• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, theFuzzy key value and the intake air temperature at that time are compared to select the setting temperatureautomatically according to the Fuzzy rule.

• While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temper-ature.

Page 42: Multi Type Air Conditioner - SERVICE MANUAL

42 Multi type Air Conditioner

Operation

2) Fuzzy Operation for Dehumidification• According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5°C(32.9°F) or more

below the setting temp, the compressor is turned off. When 0.5°C(32.9°F) or more above the setting temp, thecompressor is turned on.Compressor ON Temp Setting Temp + 0.5°C(32.9°F)Compressor OFF Temp Setting Temp+0.5°C(32.9°F)

• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to theintake air temp at that time.26°C(78.8°F) ≤ Intake Air Temp 25°C(77°F)24°C(75.2°F) ≤ Intake Air Temp<26°C(78.8°F) Intake Air Temp+1°C(33.8°F)22°C(71.6°F) ≤ Intake Air Temp<24°C(75.2°F) Intake Air Temp+0.5°C(32.9°F)18°C(64.4°F) ≤ Intake Air Temp<22°C(71.6°F) Intake Air TempIntake Air Temp<18°C(64.4°F) 18°C(64.4°F)

• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, theFuzzy key value and the intake air temperature at that time are compared to select the setting temperatureautomatically according to the Fuzzy rule.

• While in Fuzzy operation, the airflow speed of the indoor fan repeats the low airflow speed or pause as indehumidification operation.

3) Fuzzy Operation for Heating

• According to the setting temperature selected by Fuzzy rule, when the intake air temp is 3°C(37.4°F) or moreabove the setting temp, the compressor is turned off. When below the setting temp, the compressor is turnedon.Compressor ON Temp Setting TempCompressor OFF Temp Setting Temp + 3°C(37.4°F)

• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to theintake air temp at that time.20°C(68°F)≤Intake Air Temp Intake Air Temp + 0.5°C(32.9°F)Intake Air Temp<20°C(68°F) 20°C(68°F)

• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, theFuzzy key value and the intake air temperature at that time are compared to select the setting temperatureautomatically according to the Fuzzy rule.

• While in Fuzzy operation, the airflow speed of the indoor fan is set to the high or the medium according to theintake air temperature and the setting temperature.

Airflow Speed Selection• The airflow speed of the indoor fan is set to high, medium, low, or power (auto) by the input of the airflow

speed selection key on the remote control.

On-Timer Operation• When the set time is reached after the time is input by the remote control, the appliance starts to operate.• The timer LED is on when the on-timer is input. It is off when the time set by the timer is reached.• If the appliance is operating at the time set by the timer, the operation continues.While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temperature.

Off-Timer Operation• When the set time is reached after the time is input by the remote control, the appliance stops operating.• The timer LED is on when the off-timer is input. It is off when the time set by the timer is reached.

Page 43: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 43

Operation

• If the appliance is on pause at the time set by the timer, the pause continues. Off-Timer <=> On-Timer Operation

• When the set time is reached after the on/off time is input by the remote control, the on/off-timer operation iscarried out according to the set time.

Sleep Timer Operation• When the sleep time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is input by the remote control while in appli-

ance operation, the operation of the appliance stops.• While the appliance is on pause, the sleep timer mode cannot be input.• While in cooling mode operation, 30 min later since the start of the sleep timer, the setting temperature

increases by 1°C(33.8°F). After another 30 min elapse, it increases by 1°C(33.8°F) again.• When the sleep timer mode is input while in cooling cycle mode, the airflow speed of the indoor fan is set to

the low.• When the sleep timer mode is input while in heating cycle mode, the airflow speed of the indoor fan is set to

the medium.

Chaos Swing Mode• By the Chaos Swing key input, the upper/lower vane automatically operates with the Chaos Swing or they are

fixed to the desired direction.• While in Chaos Swing mode, the angles of cooling and heating cycle operations are different.

Chaos Natural Wind Mode• When the Chaos Natural Wind mode is selected and then operated, the high, medium, or low speed of the air-

flow mode is operated for 2~15 sec. randomly by the Chaos Simulation.

Jet Cool Mode Operation • While in heating mode or Fuzzy operation, the Jet Cool key cannot be input. When it is input while in theother mode operation (cooling, dehumidification, ventilation), the Jet Cool mode is operated.• In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation.• In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18°C(64.4°F).• When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.• When the Jet Cool key is input, the upper/lower vanes are reset to those of the initial cooling mode and then

operated in order that the air outflow could reach further.

Auto Restarting Operation• When the power is restored after a sudden power failure while in appliance operation, the mode before the

power failure is kept on the memory and the appliance automatically operates in the mode on the memory.

Page 44: Multi Type Air Conditioner - SERVICE MANUAL

44 Multi type Air Conditioner

Operation

Forced Operation • To operate the appliance by force in case that the remote control is lost, the forced operation selection switch

is on the main unit of the appliance to operate the appliance in the standard conditions.• When the power is supplied while the slide switch is on the forced operation position, or when the slide switch

position is switched to the Auto Restarting (or test operation) position or switched from the remote controlposition to the forced operation position while the power is on, the forced operation is carried out.

• When the slide switch position is switched from the forced operation position to the Auto Restarting position orthe remote control position, the forced operation is canceled and the appliance stops operating.

• In the forced operation mode, the indoor fan is operated at low speed for around 15 sec and then the opera-tion condition is set according to the intake air temperature as follows.24°C(75.2°F)≤Intake Air Temp Cooling Mode Operation, 22°C(71.6°F), High Speed21°C(69.8°F)≤Intake Air Temp<24°C(75.2°F) Dehumidification Operation, 23°C(73.4°F), High SpeedIntake Air Temp<21°C(69.8°F) Heating Mode Operation, 24°C(75.2°F), High Speed

Buzzer Sounding Operation• When the appliance-operation key is input by the remote control, the short "beep-beep-" sounds.• When the appliance-pause key is input by the remote control, the long "beep—" sounds.

Page 45: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 45

"Wall Mounted Type is standard"* Functions is dependent on model type.

Operation

Function of Indoor Unit

On/Off : Lights up during the system operation.

Sleep Mode : Lights up during Sleep Mode Auto operation.

Timer : Lights up during Timer operation.

Defrost ModeOutdoor unit operation

: Lights up during Defrost Mode or Hot Start operation (Heat pump model only)

: Lights up during outdoor unit operation.(Cooling model only)

Desire temperature For cooling,dehumidification,heating modes it display Destired temperatureindicator • Cooling : 18°C~30°C(64°F~86°F) • AI : Auto Operation

• Dehumidification : 18°C~30°C(64°F~86°F) • Po : Jet Cool• Heating : 16~30°C(60°F~86°F) • Lo : Test Mode

Plasma : The function illustrates its dynamic mode by using a multiple lighting system. (Optional)

• Room temperature sensor. (THERMISTOR)

• Maintains the room temperature in accordance with the Setting Temp.

• Indoor fan is delayed for 5 seconds at the starting.

• Restarting is delayed for approx. 3 minutes.

• High, Med, Low, Chaos, Jet Cool

• Intermittent operation of fan at low speed.

• The fan is switched to low(Cooling), med(Heating) speed.• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.

• The fan is switched to intermittent or irregular operation• The fan speed is automatically switched from high to low speed.

• The louver can be set at the desired position or swing up and down automatically.(Model base)

Split Type Indoor Unit

Operation ON/OFF by Remote controller

Sensing the Room Temperature

Room temperature control

Starting Current Control

Time Delay Safety Control

Indoor Fan Speed Control

Operation indication Lamps (LED)

Soft Dry Operation Mode

• Both the indoor and outdoor fanstops during deicing.

• Hot start after deice ends.

• The indoor fan stops until the evaporator piping temperature willbe reached at 27°C(80.6°F).

Sleep Mode Auto Control

Natural Air Control by CHAOS Logic

* Airflow Direction Control

Deice (defrost) control (Heating)

Hot-start Control (Heating)

Page 46: Multi Type Air Conditioner - SERVICE MANUAL

46 Multi type Air Conditioner

Operation

• Room temperature sensor. (THERMISTOR)

• Maintains the room temperature in accordance with the Setting Temp.

• Indoor fan is delayed for 5 sec at the starting.

• Restarting is inhibited for approx. 3 minutes.

• High, Med, Low, CHAOS, JET COOL

• Intermittent operation of fan at low speed.

• The fan is switched to low(Cooling), med(Heating) speed.• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.

• The fan is switched to intermittent or irregular operation• The fan speed is automatically switched from high to low speed.

• The louver can be set at the desired position or swing up and down automatically.

Art Cool Type Indoor Unit

Operation ON/OFF by Remote controller

Sensing the Room Temperature

Room temperature control

Starting Current Control

Time Delay Safety Control

Indoor Fan Speed Control

Operation indication Lamps (LED)

Soft Dry Operation Mode

• The function will be operated while in anyoperation mode with selecting the function.

• The function is to be stopped while it isoperating with selecting the function.

• Both the indoor and outdoor fan stops dur-

ing defrosting.

• The indoor fan stops until the evaporator pipe temperature will be reachedat 28°C(82.4°F).

Sleep Mode Auto Control

Natural Air Control by CHAOS Logic

Airflow Direction Control

Defrost(Deice) control (Heating)

Hot-start Control (Heating)

PLASMA

: Lights up during the system operation.

Sleep Mode : Lights up during Sleep Mode Auto operation.

Timer : Lights up during Timer operation.

Defrost Mode : Lights up during Defrost Mode or Hot Start operation.(Heat pump model only)

PLASMA : Indicate PLASMA purifier operation.

On/Off

Desire temperature For cooling,dehumidification,heating modes it display Destired temperatureindicator • Cooling : 18°C~30°C(64°F~86°F) • AI : Auto Operation

• Dehumidification : 18°C~30°C(64°F~86°F) • Po : Jet Cool• Heating : 16~30°C(60°F~86°F) • Lo : Test Mode

Outdoor unit operation

: Lights up during outdoor unit operation.(Cooling model only)

Page 47: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 47

Operation

Function of Outdoor Unit

Outdoor Unit

Two Comp algorithm

Operating Step

LEV Control

Out door Fan Control

• Compressor step varies considering condition such as room temp,outdoor temp, operating room number,Temp gap between room temp and set temp and so on.

• LEV pulse is modulated to keep constant superheat or subcooling.

• Outdoor fan operates at High or Off to respond to the load condition.

R/Valve Control(Heating Model Only)

• Convert R/Valve to change cooling to heating, heating to cooling.

Defrost Function

• After 45 min heating operation, check the defrost condition and if outdoor pipe temp is below -5°C(23°F) and released from deice operation in case outdoor pipe temp is over 12°C(53.6°F) or 9 min cooing mode.

• To deice outdoor heat exchanger in low temp condtion, convert operating mode from heating to

Oil Return System

• In single(one) comp operation duration, another comp will operate for 30 seconds every 1 hours.

Comp Overload Protection

• To protect comp from being overload, protector will turn off the comp.

High Pressure Protction

• If cycle pressure is too high(around 36.7 kgf/cm2), it will turn off comp A

• Inverter Comp is first priority and then Constant Comp is turning on responding to load condtion.

Page 48: Multi Type Air Conditioner - SERVICE MANUAL

48 Multi type Air Conditioner

Operation

Remote Control Operation

ON OFF

CANCEL

AUTO CLEAN

°C/°F

SET

Cooling Operation

Auto Operation

Healthy Dehumidification Operation

Flip-up door(opened)

Heating Operation

Signal transmitter

• Cooling Model( ), Heat Pump Model( )

5 1

3

10

916

1712

1815

6

4

2711813

14

Operation Mode

The Remote Controller transmits the signals to the system.

START/STOP BUTTONOperation starts when this button is pressed and stops whenthe button is pressed again.

OPERATION MODE SELECTION BUTTONUsed to select the operation mode.

ROOM TEMPERATURE SETTING BUTTONSUsed to select the room temperature.

INDOOR FAN SPEED SELECTORUsed to select fan speed in four stepslow, medium, high and CHAOS.

JET COOLUsed to start or stop the speed cooling/heating. (Speed cooling/heating operates super high fan speed.)

CHAOS SWING BUTTONUsed to stop or start louver movement and set the desiredup/down airflow direction.

ON/OFF TIMER BUTTONSUsed to set the time of starting and stopping operation.

TIME SETTING BUTTONSUsed to adjust the time.

TIMER SET/CANCEL BUTTONUsed to set the timer when the desired time is obtained and to cancelthe Timer operation.

SLEEP MODE AUTO BUTTONUsed to set Sleep Mode Auto operation.

AIR CIRCULATION BUTTONUsed to circulate the room air without cooling or heating.

ROOM TEMPERATURE CHECKING BUTTONUsed to check the room temperature.

PLASMA(OPTIONAL)Used to start or stop the plasma-purification function.

RESET BUTTONInitialize remote controller.

2nd F ButtonUsed prior to using modes printed in blue at the bottom of buttons.

AUTO CLEANUsed to set Auto Clean mode.˚C TO ˚F SWITCHING BUTTONUsed to switch temperature reading from Centigrade to Fahrenheit.

HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (NOT ONALL MODELS)Used to set the desired horizontal airflow direction.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

16

17

18

15

(Heat Pump) (Cooling Only)

Page 49: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 49

Disassembly

DisassemblyIndoor Unit

Split Type Indoor Unit

Disconnect the unit from power supply before mak-ing any checks.Be sure the power switch is set to “OFF”.

To remove the Grille from the Chassis. • Set the up-and-down air discharge louver to open

position (horizontally) by finger pressure.• Remove the securing screws.• To remove the Grille, pull the lower left and right

side of the grille toward you (slightly tilted) and lift itstraight upward.

1. Before removing the control box, be sure totake out the wire screwed at the other end.

EarthConductor

Page 50: Multi Type Air Conditioner - SERVICE MANUAL

50 Multi type Air Conditioner

Disassembly

2. To remove the Control Box.• Remove securing screws. • Pull the control box out from the chassis

carefully.

3. To remove the Discharge Grille.• Unhook the discharge grille and pull the

discharge grille out from the chassis carefully.

4. To remove the Evaporator. • Remove 3 screws securing the evaporator(at the

left 2EA in the Eva Holder, at the right 1EA).

Screw

• When repair, do not damage the Caution label.

Page 51: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 51

Disassembly

• Unhook the tab on the right inside of the chassisat the same time, slightly pull the evaporatortoward you until the tab is clear of the slot.

5. To remove the Motor Cover• Remove 2 securing screw.• Pull the motor cover out from the chassis

carefully.

6. To remove the Cross-Flow Fan• Loosen the screw securing the cross-flow fan to

the fan motor (do not remove).• Lift up the right side of the cross-flow fan and the

fan motor, separate the fan motor from thecross-flow fan.

• Remove the left end of the cross-flow fan fromthe self-aligning bearing.

Motor cover

Bearing

Cross-flow fan

Page 52: Multi Type Air Conditioner - SERVICE MANUAL

52 Multi type Air Conditioner

Disassembly

Art Cool Type Indoor Unit

CAUTION: Disconnect the unit frompower supply before making anychecks.Be sure the power switch is set to“OFF”.

1. To remove the Grille from the Chassis. - Pull the grille bottom, the remove 2 securing screws.- Lift the both lower parts of panel front.- After pull down this panel a bit, separate connecting

wire with product.

2. To remove the Control Box.- Before removing the control box, be sure to

disconnect the wires from PWB.- Pull the cover control out from the control box

and disconnect other wires.- Remove securing screws.- Pull the control box out from the chassis carefully.

Step Motor Connectors

Sensor Connector

Comp Connector

4Way/Fan Connector

MotorConnectorPower Connector

Power ConnectorComp Connector

Panel Front Connector

Page 53: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 53

Disassembly

3) To remove the Evaporator.- Remove 4 screws securing the evaporator.- Pull the evaporator out from the chassis carefully.

4) Before removing the Turbo Fan.- Remove the securing screws from the chassis.- Pull the pipe cover, top cover and the air guide.

5) To remove the Motor.- Remove the securing bolt from the motor shaft.- Pull the fan out from the motor shaft.- Remove 4 screws securing motor mount from the

chassis and lift up the motor mount and the brack-et.

Top Cover

Pipe Cover

Air Guide

Turbo Fan

Bracket

Bolt Motor Mount

Page 54: Multi Type Air Conditioner - SERVICE MANUAL

54 Multi type Air Conditioner

Schematic Diagram

Schematic DiagramElectronic Control Device

1. Indoor Unit1) Split Type

Page 55: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 55

Schematic Diagram

2) Art Cool Type

OU

TD

OO

R

6417

Digit2 10

LED

2

LED

4

LED

3

LED

1

DE

FR

OS

T

ON

/OF

F

TIM

ER

SLE

EP

6(d)

Digit1 c5

d

e

8(c)

7(e)

b

g

f

a

9(b)

1(g)

3(a)

4(f)

41216

15 14 13 81011 9 67 5 23 1

45

2722

2019

1821

2524

2326

37

3230

2928

31.

33 34 3536

4139

38

40 4342

44

5459

6162

6360

5657

5855

4952

5153

50

4746

48

HV

B A

SS

Y2 31

2 31

CN

-HV

B(B

L)

21 1

2

Vdd0

VssO

R28H

20K

R27H

20K

DIS

PLA

Y

44

ST

EP

PIN

G M

OT

OR

ST

EP

PIN

G M

OT

ORK

EY

TE

ST

Vcc

RE

CE

IVE

R

Vout

GN

D

DC

5V

25V0.01C

04LC

N-M

AIN 14

881013

9

10

9

7 6 5

7 6 5

14 8810

10

99

13

667

7

55 CN

-D5

114 3 2

4 3 2

11CN

-D6

113

3

22

44 CN

-D3

55

RDYLBL PK OR

443

322

BL PK YL

332

211

OR RD

55

receiver10 49 6 5 3 2 1

CN

-D2

CN

-D2(W

H)

89 7 56 4 3

C02L

10V220 5V

R12H

10K50V

C13H

103

R11H1K

Q4

5

5V

123

876D C S

Q02C

Q03C

R05G

220

R06G

220

R07G

220

5V

Q01C

LED

scan

1516

14

21 3

digit 1

digit 2

ec d

CN

-D1

CN

-D1(W

H)

2 1

5V

R02G

220

R03G

220

R04G

220

R01G

220

IC01M

KID

65004AF

12 11

13 10

5 64 7

9

8

agb f

KID

65004AF

IC02M

12V

680pF

50V

R01L

C01L

5.1K

F2

OJ02H

5V

OR

2HO

R3H

OR

6HO

R5H

OR

4HM

edS

-Hi

Hi

Low

AVss

AVdd1

AV

ret

AV

dd

RE

SE

T

X1

X2

INT

O

Vss1

INT

1

R23H

OR

1HF

1

R25H

R24H

R26H

R21H

~R

26H12.1K

1%

R22H

R21H

5V

5V

CS

T-8.00M

TW

OS

C01B

uPD

780023AG

C

0IMC

RN

E002M

CN

-UD

(BL)

12

34

5

R01E1K

12VR

02E 20P

KM

13EP

P-4002

BZ

01E

PIP

E-T

H

RO

OM

-TH

ST

EP

MO

TO

R

6.2K12.1K

R05H

10K

1%

1%2

211

R02H

R04H

5V

5V

receiver

CN

-TH

1(WH

)

3 4

3 4

CN

-LR2(W

H)

L / R 2

ST

EP

MO

TO

R

RD

12V

RD YLOR PK

1

BL

CN

-LR1(W

H)

BL

34 45

OR PKYL

L / R 1

ST

EP

PIN

G M

OT

OR

RD

PK

BL

YL

OR

SU

B P

CB

AS

M

5V

HV

B

7812

1111

11125V

10

9 8 7 6 5 4 3 2 1

8910 12345677 6 5 4 3 210

9 8 1

9 8 7 6 5 4 3 2 1

9 8 7 6 5 4 3 2 1123456789

HV

B P

IN1

1011121313

12 11

10

5 4 2 13

5 4 2 133 1245

51

24

3

14 13 12

14 13 12

11

E3 1K

E2 1K

C02M

103

C01M

103C

03M103

CN

-D1(W

H)

CN

-CO

N(W

H)

CN

-12V(W

H)

10111213

101113

12

33

22

112

2

33

11 2

2223

3 33 1

111

OJ01H

0.0125V

C01A

R02A

20K5V

1

KS

C7536

KIA

7036P

33.6V

2IC

01A

R02L1K

R01B1M

HV

B P

IN2

HV

B P

IN1

HV

B

HV

B P

IN212V

5V

DC

5V

103C

06DC

01D

35V2200uF

DC

12V+

IC02D

7805

C05D

25V470uF

+

O

C04D

10450V

II

C03D

25V470uF O

7812

IC01D

104C

02D

50V

+

+-

R97

10K

R96

10K

DC

5V

324

IC9-1

KA

393

DC

12V

81

R95

10K

63V100uFC

07D

CN

-MO

TO

R1(W

H)

MO

TO

R1

IND

OO

RF

AN

34

34

11

22

+

104,50V

CN

-DC

/DC

(BL)

PO

LY S

W1

RX

E250

~3 24

3 24

1/4W

C92

11

DC

5V

R90 1K

C91

103

5

IC9-2

KA

393

-

R92 10K

4.7KR

917+

6

R93 10K

2 31 4

DC

12V

2 31

R99

750

4

C03L

L3

10V220

RX

D

TX

D

TX

D

RX

D

FG

C81

103

R81 1K

FG

1

FG

1 EE

PR

OM

21516

1 710

13 11

1214

4 653

9

8

13 143

15 16

2 1

KID

65004AF

IC03M

10 116

125 4

98 7

12V

42

3FA

NIN

DO

OR

MO

TO

R2

1

42

31 R

XE

250

~ PO

LY S

W2

FG

2

DC

12V

CN

-MO

TO

R2(W

H)

R81A

1KF

G2

C81A

103

Page 56: Multi Type Air Conditioner - SERVICE MANUAL

56 Multi type Air Conditioner

Schematic Diagram

2. Outdoor Unit

Page 57: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 57

Schematic Diagram

Page 58: Multi Type Air Conditioner - SERVICE MANUAL

58 Multi type Air Conditioner

1. Room Type Indoor Unit -S4/SE chassis 2. Art Cool Type Indoor Unit

Wiring Diagram

Schematic Diagram

3. Outdoor Unit1. A3UH363FA0(LMO360H) 2. A3UC363FA0(LMO360C)

3. A2UH243FA0(LMO240H) 4. A2UC243FA0(LMO240C)

Page 59: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 59

Schematic Diagram

1. Indoor UnitMAIN P.C.B ASM1) Split Type

Components Locations

• TOP VIEW

• BOTTOM VIEW

PCB :6870A90409BASSY:6871A20771

6871A20782

Page 60: Multi Type Air Conditioner - SERVICE MANUAL

60 Multi type Air Conditioner

Schematic Diagram

2) Art Cool Type

• TOP VIEW

• BOTTOM VIEW

Page 61: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 61

Schematic Diagram

2. Display ASSEMBLY1) Split Type (6871A20680)

2) Art Cool Type (6871A20462)

BOTTOM VIEW

TOP VIEW

Page 62: Multi Type Air Conditioner - SERVICE MANUAL

62 Multi type Air Conditioner

Schematic Diagram

3. Outdoor Unit1) Component side

Page 63: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 63

Schematic Diagram

2) Solder side

Page 64: Multi Type Air Conditioner - SERVICE MANUAL

Troubleshooting Guide

64 Multi type Air Conditioner

S/W

Cons.

Comp(GK094K)

C/V1C/V2

Th1Th2

Acc.A-Room B-Room

LEV-A

LEV-B

AirSensor

Eva.Sensor

Eva.Sensor

9.52

6.35

LEV 15RC

R/Valve5220AR3228E

AirSensor

strainer

strainer

Sensor

Cons.

Comp(GK141K)

Ø

Ø

1. A2UH243FA0(LMO240H)

2. A2UC243FA0 (LMO240C)

Troubleshooting Guide

Refrigeration Cycle Diagram

Page 65: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 65

Field PipingGas

Field PipingLiquid

Refrigerant Flow

Th1: Discharge thermistorTh2: Discharge thermistorTh3: Outdoor temperature thermistor

Room A

Cooling

LEV-B

LEV-A

HeatExchanger

Header

OUTDOOR UNIT

Room BØ9.52

Room A

Room BØ6.35

Ø6.35

Ø6.35

Ø9.52

Room CØ9.52

Th2

High pressure S/W

Th3

Th1

LEV-CRoom C

Co

nst

ant

Co

mp

ress

or

Co

nst

ant

Co

mp

ress

or

Acc

um

ula

tor

Refrigerant Flow

Cooling

Heating

Th1: Discharge thermistorTh2: Discharge thermistorTh3: Outdoor temperature thermistorTh4: Defrost thermistor

Field PipingGas

Field PipingLiquid

Room A

LEV-B

LEV-A

HeatExchanger

Header

OUTDOOR UNIT

Room BØ9.52

Room A

Room BØ6.35

Ø6.35

Ø9.52

Room CØ9.52

Th2

High pressure S/W

Th3

Th4

Th1

LEV-CRoom C

Ø6.35

Co

nst

ant

Co

mp

ress

or

Co

nst

ant

Co

mp

ress

or

Acc

um

ula

tor

3. A3UH363FA0(LMO360H)

4. A3UC363FA0(LMO360C)

Troubleshooting Guide

Page 66: Multi Type Air Conditioner - SERVICE MANUAL

66 Multi type Air Conditioner

Troubleshooting Guide

Error Indicator

• The function is to self-diagnoisis airconditioner and express the troubles identifically if there is any trouble.• Error mark is ON/OFF for the operation LED of evaporator body in the same manner as the following table.• If more than two troubles occur simultaneously, primarily the highest trouble fo error code is expressed.• After error occurrence, if error is released, error LED is also released simultaneously.• To operate again on the occurrence of error code, be sure to turn off the power and then turn on.• Having or not of error code is different from Model.

Self-diagnosis Function

00 No Error ON

01 Indoor Room Thermistor Error 1 time OFF

02 Indoor In-Piping Error 2 times OFF

05 Communication Error between In and Out 5 times OFF

06 Indoor Out-Piping Error 6 times OFF

07 Differnt mode operation 7 times OFF

10 Indoor fan motor locked error 1 times OFF

Error code Description MPS Variable LED1 LED2 Indoor Status

33 D-Pipe High(Normal) 3 times 3 times OFF

44 Outdoor Air Thermistor Error(Open/Short) 4 times 4 times OFF

45 Cond Pipe Thermistor Error(Open/Short) 4 times 5 times OFF

47 Const. D-Pipe Thermistor Error(Open/Short) 4 times 7 times OFF

51 Capcity Error(High/Low) 5 times 1 times OFF

Error code Description MPS Variable LED1(Red) LED2(Green) Indoor Status

Indoor Error

Outdoor Error

LED1 LED2

Page 67: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 67

Troubleshooting Guide

Trouble analysis1. Check temperature difference between intake and discharge air, and operating current.

All amount of refrigerant leaked out. Check refrigeration cycle.

Refrigerant leakageClog of refrigeration cycleDefective compressor

Excessive amount of refrigerant

Normal

Notice:Temperature difference between intake and discharge air depends on room air humidity. When the room airhumidity is relatively higher, temperature difference is smaller. When the room air humidity is relatively lowertemperature difference is larger.

2. Check temperature and pressure of refrigeration cycle.

Notice:1. The suction pressure is usually 4.5~6.0 kg/cm2G at normal condition.2. The temperature can be measured by attaching the thermometer to the low pressure tubing and wrap it with

putty.

Temp. difference : approx. 0°C(32°F)Current : less than 80% of

rated current

Temp. difference : approx. 8°C(46.4°F)Current : less than 80% of

rated current

Temp. difference : less than 8°C(46.4°F)Current : near the rated cur-

rent

Temp. difference : over 8°C(46.4°F)

Temp. Difference

Operating Current

Suction pressure Temperature(Compared with (Compared with Cause of Trouble Description

the normal value) the normal value)

High Defective compressor Current is low.

Normal Excessive amount of High pressure does not quickly refrigerant rise at the beginning of operation.

Insufficient amount of Current is low.Lower Higher refrigerant(Leakage)

Clogging

Higher

Cycle Troubleshooting Guide

Page 68: Multi Type Air Conditioner - SERVICE MANUAL

68 Multi type Air Conditioner

Troubleshooting Guide

Electronic Parts Troubleshooting Guide

Refer to electronic contorol device drawing & schematic diagram.

The Product doesn’t operate at all.

Turn off the main power and wait until LED on outdoor PCB is off.

Turn on the main power again.

Does "Beeping" sound is made from the indoor unit?

• Primarily, the operating condi-tion of Micom is O.K.

• Check CN-DISP1

Check the voltage of power(AC208V/AC230V, 60Hz).

• The voltage of main power.• The voltage applied to the unit.• The connecting method of Indoor/Outdoor connecting cable (each color)• The P.W.B. Ass'y(Fuse, Noise Filter, Power Transformer, IC01D, IC02D, etc.)

Trouble 1

NO YES

The operation check of the P.C.B. Ass'y

Procedure

1) The input voltage of power trans-former.

2) The output voltage of powertransformer.

3) IC01D(7812)

4) IC02D(7805)

5) IC01A(KIA7036)

Specification

1) AC230V ± 30V: Check the rated voltage

2) 15V ± 1.5V

3) DC12V

4) DC5V

5) The voltage of micom pin 29 : DC4.5V↑

Remedy

1) Replace power transfomer.

2) Replace power transfomer.

3) Replace IC01D.

4) Replace IC02D.

5) Replace IC01A.

Page 69: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 69

Troubleshooting Guide

Turn on main power.

While the compressor has been stopped, the compressor does not operate owing to the delaying function for 3 minutes after stopped.

When the compressor stopped Indoor Fan is driven by a low speed.At this point the wind speed is not controlled by the remote controller.

(When operated in the Sleeping Mode, the wind speed is set to the low speed as force.)

Caused by the remote controller. Caused by other parts except the remote controller

When the mark ( ) is displayed in LCDscreen, replace battery.

Check the contact of CN-DISP 1 connector

When the detect switch (double key) inside theremote controller door is fault, it is impossible tooperate temperature regulating( / ) and wind

speed selecting.

Check DISP PWB Ass'y -Voltage between CN1 ➀ - ➆ : DC +5V

Check the Display PWB Ass'y • Check receiver ass'y

Product doesn't operate with the remote controller.Trouble 2

Page 70: Multi Type Air Conditioner - SERVICE MANUAL

70 Multi type Air Conditioner

Troubleshooting Guide

Turn on the main power.

When in air circulation mode, compressor/outdoor fan is stopped.

Turn off main power.

Check the electrical wiring diagram of Outdoor side.Check the open or short of connecting wires between Indoor and Outdoor.

Check the sensor for Indoor temperature is attatched as close as to be effected by thethemperature of Heat Exchange (EVA.)

When the sensor circuit for Indoor temperature and connector are in bad connection or arenot engaged, Compressor/Outdoor fan is stopped.

• Check the related circuit of R01H(1K), R02H(1K), R03H(1K), R04H(1K), Micom(pin No. 74 ,

75 , 76 , 77 ).• Check the Indoor temperature sensor is disconnected or not (about 10K at 25°C).

Check the Relay(RY-PWR, RY-START) for driving Compressor.

• Check the voltage between brown and blue cable of terminal to connect the Outdoor(About AC208V / 230V).

• Check the related circuit of relay in Outdoor PCB Ass'y.

Operate Cooling Mode by setting the disired temperature of the remote controller is lessthan one of the Indoor temperature by 1°C at least.

The Compressor/Outdoor Fan are don't operateTrouble 3

Check Point

Between Micom(No. 50,51) andGND

DC 5V DC 0V

DC 12VDC 1V↓Between IC01M(No. 10) andGND

Comp. ON Comp. OFF

Page 71: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 71

Troubleshooting Guide

When indoor Fan does not operate.

Check connecting condition of the CN-MOTOR CON-NECTOR

Does the voltage of terminal of CN-DC/DC CONNECTOR inIndoor unit corresponds to the values in the table of page 56

Do the voltage of terminal ofCN-DC/DC CONNECTOR inOutdoor unit corresponds to thevalues in the table of page 56

Check the patterns and theconditions of outdoor unitPWB Assy's.

Check the connecting condi-tion and disconnection ofconnecting wires betweenIndoor and Outdoor unit.

Check the pattern and thecondition of Indoor unit PWBAss'y.

Check the interference of Indoor Fan.

Does the voltage of each terminals of CN-MOTOR CONNECTOR inIndoor unit corresponds to values in the Table of page 69

Check the motor of Indoor Fan

Indoor Fan may be stopped in the Soft Dry Mode(change to the Cooling Operation Mode).

Indoor Fan is to be stopped when Indoor pipe(coil) termperature is lower than 79°F.

(At that times, Defrost indicator is turned on)

NO YES

When indoor Fan does not operate.Trouble 4

Page 72: Multi Type Air Conditioner - SERVICE MANUAL

72 Multi type Air Conditioner

Troubleshooting Guide

When the louver does not operate.Trouble 5

When Vertical Louver does not operate.

• Confirm that the Vertical Louver is normally geared with the shaft ofStepping Motor.

• If the regular torque is detected when rotating the Vertical Louver withhands Normal

• Check the connecting condition of CN-UP/DOWN Connector• Check the soldering condition(on PWB) of CN-UP/DOWN Connector

Check the operating circuit of the Vertical Louver

• Confirm that there is DC +12V between pin (RED) of CN-UP/DOWN andGND.

• Confirm that there is a soldering short at following terminals.- Between 60 , 61 , 62 and 63 of MICOM- Between 2 , 3 , 4 and 5 of IC01M- Between 12 , 13 , 14 , 15 of IC01M- Between 1 , 2 , 3 , 4 and 5 of CN-UP/DOWN

If there are no problems after above checks

• Confirm the assembly conditions that are catching and interfering parts inthe rotation radial of the Vertical Louver

Page 73: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 73

Troubleshooting Guide

Error Code

Trouble Shooting

ErrorTitle Cause of error Check point & Normal conditioncode

01 Indoor air sensor

02 Indoor inlet pipe sensor

06 Indoor outlet pipe sensor

• Open / Short• Soldered poorly• Internal circuit error

• Open / Short• Soldered poorly• Internal circuit error

• Open / Short• Soldered poorly• Internal circuit error

Normal resistor : 10KΩ / at 25°C (Unplugged)Normal voltage : 2.5Vdc / at 25°C (plugged)

Normal resistor : 5KΩ/ at 25°C (Unplugged)Normal voltage : 2.5Vdc / at 25°C (plugged)

Normal resistor : 5KΩ/ at 25°C (Unplugged)Normal voltage : 2.5Vdc / at 25°C (plugged)

Ω

10KΩ 2.5Vdc

Check the resistance / voltage

V

Check Point

1. Unplug the sensor on Indoor unit PCB.

2. Estimate the resistance of each sensor

3. If the resistance of the sensor is 10KΩ/5KΩ at 25°C, then sensor is normal

4. If the resistance of the sensor is 0 KΩ or ∞, then sensor is abnormal. Change the sensor.

5. Plug the sensor on Indoor unit PCB and Power ON.

6. Estimate the voltage of each sensor.

7. If the voltage of the sensor is 2.5Vdc / at 25°C, then sensor is normal.

8. If the resistance of the sensor is 0 or 5Vdc, then sensor is abnormal. Repair or Change the PCB

Page 74: Multi Type Air Conditioner - SERVICE MANUAL

74 Multi type Air Conditioner

Troubleshooting Guide

ErrorTitle Cause of error Check point & Normal conditioncode

05 / 53Communication (Indoor Outdoor) • Communication poorly

• Power input AC 230V.(Outdoor, Indoor)• The connector for transmission is disconnected.• The connecting wires are misconnected.• The GND 1,2 is not connected at main GND.• The communication line is shorted at GND.• Transmission circuit of outdoor PCB is abnormal.• Transmission circuit of indoor PCB is abnormal.

Check Point

1. Check the input power AC 230V.(Outdoor, Indoor)

2. Check the communication wires are correctly connected.

Adjust the connection of wire

Confirm the wire of "Live", "Neutral".

3. Check the resistance between communication line and GND.(Normal : Over 2MΩ)

4. Check the connector for communication is correctly connected.

5. Check the connection of GND1, GND2, and main GND.

6. If one indoor unit is operated normally, outdoor PCB is no problem.

Check the another indoor unit.

* CH05 is displayed at indoor unit, CH53 is displayed at outdoor unit.

Page 75: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 75

Troubleshooting Guide

ErrorTitle Cause of error Check point & Normal conditioncode

33 D-Pipe Temp. High • Discharge sensortemp. high

• Check the discharge pipe sensor.• Check the install condition for over load.• Check the leakage of refrigerent.• Check the SVC V/V open.

ErrorTitle Cause of error Check point & Normal conditioncode

51 Capacitor error • Over Capacitor com-bination

• Check the indoor unit capacity.• Check the combination table

Check Point

1. Check the indoor unit capacity.

2. Check the combination table.

In the tropical model case

single cycle has no error for over capacity.

Check Point

1. Check the install condition for over load.

2. Check the SVC V/V open.

3. Check the leakage of refrigerent.

4. Check the constant compressor.

COMP OFF

LEV OPEN(16PULSE/MIN)

LEV OPEN(10PULSE/MIN)

NORMAL

A3UH363FA0(LMU360HE)/A3UC363FA0(LMU360CE)

115°C(239°F)

100°C(212°F)

95°C(203°F)

Page 76: Multi Type Air Conditioner - SERVICE MANUAL

76 Multi type Air Conditioner

Troubleshooting Guide

ErrorTitle Cause of error Check point & Normal conditioncode

44 Outdoor air sensor

45 Condensor pipe sensor

47 D-Pipe sensor

• Open / Short• Soldered poorly• Internal circuit error

• Open / Short• Soldered poorly• Internal circuit error

• Open / Short• Soldered poorly• Internal circuit error

Normal resistor : 10KΩ / at 25°C(77°F) (Unplugged)Normal voltage : 2.5Vdc / at 25°C(77°F) (plugged)

Normal resistor : 5KΩ/ at 25°C(77°F) (Unplugged)Normal voltage : 2.5Vdc / at 25°C(77°F) (plugged)

Normal resistor : 200KΩ/ at 25°C(77°F) (Unplugged)Normal voltage : 4.5Vdc / at 25°C(77°F) (plugged)

Check Point

1. Estimate the resistance of each sensor.(Unplugged)

2. Estimate the voltage of each sensor.(Plugged)

3. If the resistance is 0V or 5Vdc, then sensor is abnormal

Check the resistance

Ω

Ω

Page 77: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 77

2-way, 3-way Valve

2-way, 3-way Valve

2-way Valve (Liguid Side) 3-way Valve (Gas Side)

Works Shaft position Shaft position Service port

Shipping Closed Closed Closed(with valve cap) (with valve cap) (with cap)

Air purging Open Closed Open(Installation) (counter-clockwise) (clockwise) (push-pin or with

vacuum pump)

Operation Open Open Closed(with valve cap) (with valve cap) (with cap)

Pumping down Closed Open Open(Transfering) (clockwise) (counter-clockwise) (connected

manifold gauge)

Evacuation Open Open Open(Servicing) (with charging

cylinder)

Gas charging Open Open Open(Servicing) (with charging

cylinder)

Pressure check Open Open Open(Servicing) (with charging

cylinder)

Gas releasing Open Open Open(Servicing) (with charging

cylinder)

3.

2.

1.

4.

5.

6.

Flare nut

To piping connection

Open positionClosed position

Flare nut

Valve cap

To piping connection

Open positionClosed position

Hexagonal wrench(4mm)

To outdoor unit

Pin

Service port

Service port cap

To outdoor unit

Page 78: Multi Type Air Conditioner - SERVICE MANUAL

78 Multi type Air Conditioner

2-way, 3-way Valve

(1) Pumping down

• Procedure1. Confirm that both the gas side and liquid side

valves are set to the open position.- Remove the valve stem caps and confirm that the

valve stems are in the raised position.

- Be sure to use a hexagonal wrench to operatethe valve stems.

2. Operate the unit for 10 to 15 minutes.

3. Stop operation and wait for 3 minutes, then con-nect the manifold gauge to the service port of thegas side valve.- Connect the hose of the gauge with the push pin

to the service port.

4. Air purging of the charge hose.- Open the Low-handle valve on the gauge

slightly to air purge from the hose.

5. Set the liquid side valve to the closed position.

6. Operate the air conditioner at the cooling cycleand stop it when the gauge indicates 1kg/cm2g.

7. Immediately set the gas side valve to the closedposition.- Do this quickly so that the gauge ends up indicat-

ing 1kg/ g.

8. Disconnect the charge set, and mount the liquidside and gas side valve caps and the service portnut.- Use torque wrench to tighten the service port nut

to a torque of 1.8kg.m.(4.2kg.m/5.5kg.m)

- Be sure to check for gas leakage.

Indoor unit

Outdoor unit

Liquid side

Close

Gas side

2-Wayvalve

Open3-Wayvalve

manifold gauge

Indoor unit Liquid side

Close

Gas side

2-Wayvalve

Open3-Wayvalve

Hi- handle(CLOSE)

Low-handle(CLOSE)

• Be sure to short pressure S/W. otherwise Low pressure S/W detect low pressure skete and stops the compressor.

Page 79: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 79

2-way, 3-way Valve

(2) Evacuation(All amount of refrigerant leaked)

• Procedure1. Confirm that both the liguid side valve and gas

side valve are set to the opened position.

2. Connect the vaccum pump to the center hose ofthe manifold gauge.

3. Connect the service port of the gas side valve tothe low side of the gauge.

4. Evacuation for approximately one hour.- Confirm that the gauge needle has moved

toward-76 cmHg (vacuum of 4 mmHg or less).

5. Close the Low handle of the gauge turn off thevacuum pump, and confirm that the gauge needledoes not move(approximately 5 minutes afterturning off the vacuum pump).

6. Disconnect the charge hose from the vacuumpump.- Vacuum pump oil.

If the vacuum pump oil becomes dirty or deplet-ed,replenish as needed.

7. Mount the valve caps and the service port caps.

Indoor unit

Outdoor unit

Liquid side

Open

Gas side

2-Wayvalve

Open3-Wayvalve

manifold gauge

Indoor unit Liquid side

Open

Gas side

2-Wayvalve

Open3-Wayvalve

Vacuum pump

Hi- handle(OPEN)

Low-handle(OPEN)

Page 80: Multi Type Air Conditioner - SERVICE MANUAL

80 Multi type Air Conditioner

2-way, 3-way Valve

(3) Gas Charging(After Evacuation)

• Procedure1. Connect the gauge to the charging cylinder.

- Connect the charge hose which you disconnect-ed from the vacuum pump to the valve at thebottom of the cylinder.

- If you are using a gas cylinder, also use a scaleand reverse the cylinder so that the system canbe charged with liquid.

2. Purge the air from the charge hose.- Open the valve at the bottom of the cylinder and

press the check valve on the charge set to purgethe air. (Be careful of the liquid refrigerant). Theprocedure is the same if using a gas cylinder.

3. Open the low handle on the gauge and chargethe system with liquid refrigerant.- If the system can not be charged with the speci-

fied amount of refrigerant, it can be chargedwith a little at a time (approximately 150g eachtime) while operating the air conditioner in thecooling cycle; however, one time is not suffi-cient, wait approximately 1 minute and thenrepeat the procedure(pumping down-pin).

4. Immediately disconnect the charge hose fromthe gas side valve's service port.

- Stopping partway will allow the gas to be dis-charged.

- If the system has been charged with liquidrefrigerant while operating the air conditionerturn off the air conditioner before disconnectingthe hose.

5. Mount the valve stem nuts and the service portnut.- Use torque wrench to tighten the service port

nut to a torque of 1.8 kg.m.(4.2kg.m/5.5kg.m.)- Be sure to check for gas leakage.

manifold gaugeChargingcylinder

Hi- handle(OPEN)

Low-handle(OPEN)Check valve

Indoor unit

Outdoor unit

Liquid side

Open

Gas side

2-Wayvalve

Open3-Wayvalve

Indoor unit Liquid side

Open

Gas side

2-Wayvalve

Open3-Wayvalve

This is different from previous procedures.Because you are charging with liquid refrigerantfrom the gas side, absolutely do not attempt tocharge with larger amounts of liquid refrigerantwhile operating the air conditioner.

Page 81: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 81

135301

152302-2

152313

152302-1

342800

263230-2 263230-1

359011

131410 733010

135311

135312

159901

268712

146811

147582

346810

135516

266090

35211B

354210

249951

352150

268714

668713267110

135500

159830

Exploded View & Replacement Parts List

Exploded View & Replacement Parts ListIndoor Unit

S4 chassis

Page 82: Multi Type Air Conditioner - SERVICE MANUAL

82 Multi type Air Conditioner

Exploded View & Replacement Parts List

Parts List (S4 chassis)

PART No.

AMNC093D4L0(LMI090CP) AMNH093D4L0(LMI090HP)

131410 CHASSIS ASSEMBLY 3141A20019C 3141A20019C R

135311 GRILLE ASSEMBLY,FRONT(INDOOR) 3531A23003V 3531A18013V R

135301 GRILLE,FRONT 3530A10253A 3530A10253A R

152302-1 FILTER,AIR 5230A20051B 5230A20051B R

152302-2 FILTER,AIR 5230A20051D 5230A20051D R

135312 GRILLE ASSEMBLY,DISCHARGE(INDOOR) 3531A10307Z 3531A11362D R

159901 LOUVER,HORIZONTAL 5990A20069A 5990A20069A R

147582 LOUVER,VERTICAL 4758A30052A 4758A30052A R

146811 MOTOR,DC 4681A20055A 4681A20055A R

268712 PCB ASSEMBLY,DISPLAY 6871A20680F 6871A20680E R

135516 COVER ASSEMBLY,MOTOR 3551A20156B 3551A20156B R

346810 MOTOR,DC 4681AR2295L 4681AR2295L R

152313 FILTER ASSEMBLY,DEODORIZER 5231A20040A 5231A20040A R

249951 CASE ASSEMBLY,CONTROL(INDOOR) 4995A20831E 4995A20831E R

268714 PCB ASSEMBLY,MAIN 6871A20782A 6871A20782A R

668713 PCB ASSEMBLY(OPTION PCB) 6871A20989D 6871A20989A R

263230-1 THERMISTOR,NTC 6323AQ3226T 6323AQ3226T R

263230-2 THERMISTOR,NTC 6323A20004A 6323A20004A R

267110 REMOTE CONTROLLER ASSEMBLY 6711A20083Q 6711A20083Q R

342800 BEARING 4280A20004B 4280A20004B R

354210 EVAPORATOR ASSEMBLY,FIRST 5421A20218B 5421A20218B R

35211B TUBE ASSEMBLY,TUBING 5211A21363E 5211A21363E R

352150 HOSE ASSEMBLY,DRAIN 5251A20011B 5251A20011B R

359011 FAN ASSEMBLY,CROSS FLOW 5901A20017F 5901A20017F R

733010 PLATE ASSEMBLY,INSTALLATION 3301A20020C 3301A20020C R

135500 COVER 3550A30262A 3550A30262A R

159830 FILTER ASSEMBLY,AIR CLEANER 5983A20017A 5983A20017F R

266090 H.V ASSEMBLY 6609A10003Z 6609A10003Z R

DESCRIPTION SVCCODE

LOCATIONNo.

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.(GCSC WEBSITE http://biz.LGservice.com)

Page 83: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 83

Exploded View & Replacement Parts List

135301

152313

152302

342800

263230-2 263230-1

359011

131410 733010

135311

135312

159901

268712

146811

147582

346810

135516

266090

35211B

354210

249951

352150

268714

668713267110

135500

159830

SE chassis

Page 84: Multi Type Air Conditioner - SERVICE MANUAL

84 Multi type Air Conditioner

Exploded View & Replacement Parts List

Parts List (SE chassis)

PART No.

AMNC123DEL0(LMI120CP)

AMNH123DEL0(LMI120HP)

131410 CHASSIS ASSEMBLY 3141A20034A 3141A20034A R

135311 GRILLE ASSEMBLY,FRONT(INDOOR) 3531A18013V 3531A18013V R

135301 GRILLE,FRONT 3530A10287A 3530A10287A R

152302 FILTER,AIR 5230A20064A 5230A20064A R

135312 GRILLE ASSEMBLY,DISCHARGE(INDOOR) 3531A11362D 3531A11362C R

159901 LOUVER,HORIZONTAL 5990A20068A 5990A20068A R

147582 LOUVER,VERTICAL 4758A30057A 4758A30057A R

146811 MOTOR,DC 4681A20055A 4681A20055A R

268712 PCB ASSEMBLY,DISPLAY 6871A20680E 6871A20680C R

135516 COVER ASSEMBLY,MOTOR 3551A20156B 3551A20156B R

346810 MOTOR,DC 4681AR2295L 4681AR2295L R

152313 FILTER ASSEMBLY,DEODORIZER 5231A20040K 5231A20040K R

249951 CASE ASSEMBLY,CONTROL(INDOOR) 4995A20831E 4995A20831E R

268714 PCB ASSEMBLY,MAIN 6871A20782A 6871A20782A R

668713 PCB ASSEMBLY(OPTION PCB) 6871A20989C 6871A20989B R

263230-1 THERMISTOR,NTC 6323AQ3226T 6323AQ3226T R

263230-2 THERMISTOR,NTC 6323A20004A 6323A20004A R

267110 REMOTE CONTROLLER ASSEMBLY 6711A20083Q 6711A20128B R

342800 BEARING 4280A20004B 4280A20004B R

354210 EVAPORATOR ASSEMBLY,FIRST ADL30058601 ADL30058601 R

35211B TUBE ASSEMBLY,TUBING 5211A15008A 5211A15008A R

352150 HOSE ASSEMBLY,DRAIN 5251A20011G 5251A20011G R

359011 FAN ASSEMBLY,CROSS FLOW 5901A20017H 5901A20017H R

733010 PLATE ASSEMBLY,INSTALLATION 3301A20020A 3301A20020A R

135500 COVER 3550A30315A 3550A30315A R

159830 FILTER ASSEMBLY,AIR CLEANER 5983A20017F 5983A20017F R

266090 H.V ASSEMBLY 6609A10003Z 6609A10003Z R

DESCRIPTION SVCCODE

LOCATIONNo.

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.(GCSC WEBSITE http://biz.LGservice.com)

Page 85: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 85

Exploded View & Replacement Parts List

1355

15

2671

10

1355

00-3

2687

14

3521

50

3521

1B

2632

30-2

1475

81

3590

12

3496

00

3523

80

1468

11

1468

11

1475

81

3468

10

1475

81

2687

12

1355

00-1

1314

10

3542

10

2632

30-1

1355

00-2

1468

11

2687

17-1

2687

17-2

3308

70

1353

12

1468

11

1353

14

1598

30

2499

51

SP3 Chassis Art Cool Type

Page 86: Multi Type Air Conditioner - SERVICE MANUAL

86 Multi type Air Conditioner

Exploded View & Replacement Parts List

Parts List (SP3 chassis)

PART No.

AMNC093APM0(LMA090CP)

AMNH093APM0(LMA090HP)

AMNC123APM0(LMAN120CP)

AMNH123APM0(LMA120HP)

131410 CHASSIS ASSEMBLY 3141A20030C 3141A20030C 3141A20030C 3141A20030C R

135312 GRILLE ASSEMBLY,FRONT(INDOOR) 3531A21035T 3531A21035N 3531A21035T 3531A21035N R

135314 GRILLE ASSEMBLY,INLET 3531A20212K 3531A20212K 3531A20212K 3531A20212K R

152302 FILTER, AIR 5230A20032A 5230A20032A 5230A20032A 5230A20032A R

268712 PCB ASSEMBLY,DISPLAY 6871A20462B 6871A20462A 6871A20462B 6871A20462A R

268717-1 PCB ASSEMBLY,SUB 6871A20259B 6871A20259B 6871A20259B 6871A20259B R

268717-2 PCB ASSEMBLY,SUB 6871A20363D 6871A20363D 6871A20363D 6871A20363D R

135500-1 COVER 3550A20123C 3550A20123C 3550A20123C 3550A20123C R

135500-2 COVER 3550A20124B 3550A20124B 3550A20124B 3550A20124B R

135500-3 COVER 3550A20060A 3550A20060A 3550A20060A 3550A20060A R

135515 COVER ASSEMBLY,TOP(INDOOR) 3551A20031H 3551A20031H 3551A20031H 3551A20031H R

147581 LOUVER,HORIZONTAL 4758A20014B 4758A20014B 4758A20014B 4758A20014B R

146811 MOTOR,DC 4681A20055A 4681A20055A 4681A20055A 4681A20055A R

159830 FILTER ASSEMBLY,AIR CLEANER 5983A20007F 5983A20007F 5983A20007F 5983A20007F R

249951 CASE ASSEMBLY,CONTROL(INDOOR)4995A20832A 4995A20832B 4995A20832C 4995A20832D R

268714 PCB ASSEMBLY 6871A20387M 6871A20387K 6871A20387N 6871A20387M R

263230-2 THERMISTOR,NTC(ROOM+IN PIPE) 6323A20004N 6323A20004N 6323A20004N 6323A20004N R

263230-1 THERMISTOR,NTC(OUT PIPE) 6323AQ3226T 6323AQ3226T 6323AQ3226T 6323AQ3226T R

267110 REMOTE CONTROLLER ASSEMBLY 6711A20083R 6711A20128F 6711A20083R 6711A20128F R

330870 PAN ASSEMBLY,DRAIN 3087A30004A 3087A30004A 3087A30004A 3087A30004A R

346810 MOTOR,UNCLASSIFIED 4681A20047B 4681A20047B 4681A20047B 4681A20047B R

349600 BRACKET,MOTOR 4960A20016A 4960A20016A 4960A20016A 4960A20016A R

35211B TUBE ASSEMBLY,TUBING 5211AR7066F 5211AR7066F 5211AR7066F 5211AR7066F R

352150 HOSE ASSEMBLY,DRAIN 5251AR1222R 5251AR1222R 5251AR1222R 5251AR1222R R

354210 EVAPORATOR ASSEMBLY,FIRST 5421A20072A 5421A20072A 5421A20072A 5421A20072A R

359012 FAN,TURBO 5900A00003A 5900A00003A 5900A00003A 5900A00003A R

352380 AIR GUIDE 5238A20034A 5238A20034A 5238A20034A 5238A20034A R

DESCRIPTIONSVC

CODELOCATION

No.

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.(GCSC WEBSITE http://biz.LGservice.com)

Page 87: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 87

Exploded View & Replacement Parts List

5484

90

5522

02

5614

10

6499

50

6687

11

4355

11

5522

03-1

5522

03-2

5522

03-1

5522

03-2

5541

60-1

5541

60-2

5522

04-1

5522

04-2

2632

30-1

2632

30-2

W0C

CZ-1

W0C

CZ-2

5540

31

4355

12

5590

10

4353

01

5468

10

4479

10

4372

10

4304

11

5522

01

1372

13-2

1372

13-1

4353

00

5660

00

A2UH243FA0(LMO240H), A2UC243FA0 (LMU240C)

Outdoor Unit

Page 88: Multi Type Air Conditioner - SERVICE MANUAL

Exploded View & Replacement Parts List

88 Multi type Air Conditioner

Parts List (A2UH243FA0(LMO240H), A2UC243FA0 (LMO240C))

437210 PANEL ASSEMBLY,FRONT(SUB) 1A00197C 1A00197C R

137213-1 PANEL ASSEMBLY,SIDE 1A00202F 1A00202F R

137213-2 PANEL ASSEMBLY,SIDE 3A02284R 3A02284R R

435300 GRILLE,REAR 1A00208H 1A00208H R

435301 GRILLE,DISCHARGE 3530A20007J 3530A20007J R

435512 COVER ASSEMBLY,TOP(OUTDOOR) 3551A30113C 3551A30113C R

430411 BASE ASSEMBLY,OUTDOOR 3041AP2741G 3041AP2741G R

554031 CONDENSER ASSEMBLY,FIRST 5403A20256A 5403A20256A R

546810 MOTOR,UNCLASSIFIED 4681A20008E 4681A20008E R

559010 FAN ASSEMBLY,PROPELLER 1A00195B 1A00195B R

554160-1 COMPRESSOR SET, KOREA(LEFT) 2520UGHK2AA(GK141KAA) 2520UGHK2AA(GK141KAA) R

554160-2 COMPRESSOR SET,KOREA(RIGHT) 2520UGJK2AA(GK094KAA) 2520UGJK2AA(GK094KAA) R

447910 BARRIER ASSEMBLY,OUTDOOR 4791A30004H 4791A30004H R

649950 CASE ASSEMBLY,CONTROL(OUTDOOR) 4995A00002G 4995A00002G R

668711 PCB ASSEMBLY,MAIN 6871A20500B 6871A20500B R

435511 COVER ASSEMBLY,CONTROL(OUTDOOR) 3550AR2886C 3550AR2886C R

WOCZZ-1 CAPACITOR,FILM,BOX 2A00986G 2A00986G R

WOCZZ-2 CAPACITOR,FILM,BOX 6120AR2194F 6120AR2194F R

548490 ACCUMULATOR ASSEMBLY 4848A20012A 4848A20012A R

561410 SOLENOID(COIL ASSEMBLY, REVERSE) 3A02028Z - R

552204-1 DRAWING,ASSEMBLY(EEV COIL) 6877A20050A 6877A20050A R

552204-1 DRAWING,ASSEMBLY(EEV COIL) 6877A20050B 6877A20050B R

552203-1 VALVE,SERVICE(Ø9.52) 5220A20001K 5220A20001K R

552203-2 VALVE,SERVICE(Ø6.35) 2H02479J 2H02479J R

561411 VALVE,EXPANSION BODY 6140A90001K 6140A90001K R

552202 VALVE,REVERSE 5220AR3228E 5220AR3228E R

552201 VALVE,CHECK 5220A30004A 5220A30004A R

566000 SWITCH,PRESSURE 6600L000013 6600L000013 R

263230-1 THERMISTOR,NTC 6323A20026A 6323A20026A R

263230-2 THERMISTOR,NTC 6323A20001N 6323A20001N R

LocationNo. Description

Part No.

A2UH243FA0(LMO240H) A2UC243FA0 (LMO240C)

SVCCODE

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.(GCSC WEBSITE http://biz.LGservice.com)

Solenoid(Coil Assempy, Reverse) is only for heat pump model.

Page 89: Multi Type Air Conditioner - SERVICE MANUAL

Service Manual 89

Exploded View & Replacement Parts List

5468

10

5590

10

5521

16

5522

03-1

5522

03-2

5541

60-2

5541

60-1

5675

02

5540

31

4479

10

4304

10

4355

12

4353

01

4372

11

1372

13-2

1372

13-1

1353

14

5484

90

5521

12

5521

13

5521

17

5522

04-1

5522

04-2

5522

04-3

2632

30-1

2632

30-2

6499

50

6687

11-2

6687

11-1

W0C

ZZ-1

W0C

ZZ-2

4355

11

5614

10

A3UH363FA0(LMO360H), A3UC363FA0(LMO360C)

Outdoor Unit

Page 90: Multi Type Air Conditioner - SERVICE MANUAL

90 Multi type Air Conditioner

Exploded View & Replacement Parts List

Parts List (A3UH363FA0(LMO360H), A3UC363FA0(LMO360C))

NOTE) *Please ensure GCSC since these parts may be changed depending upon the buyer's request.(GCSC WEBSITE http://biz.LGservice.com)

Solenoid(Coil Assembly, Reverse) is only for heat pump model.

PART No.

A3UH363FA0(LMO360H) A3UC363FA0(LMO360C)

435301 GRILLE,DISCHARGE 3530A20006G 3530A20006G R

135314 GRILLE,REAR 3530A10176B 3530A10176B R

263230-1 THERMISTOR, NTC 6323A20028A 6323A20028A R

263230-2 THERMISTOR, NTC 6323A20026A 6323A20026A R

430410 BASE ASSEMBLY, OUTDOOR 3041AP2741H 3041AP2741H R

435511 COVER ASSEMBLY,CONTROL(OUTDOOR) 3551A10044G 3551A10044H R

435512 COVER ASSEMBLY,TOP(OUTDOOR) 3H03266H 3H03266H R

437211 PANEL ASSEMBLY,FRONT(OUTDOOR) 3721A10109C 3721A10109C R

447910 BARRIER ASSEMBLY,OUTDOOR 4791A10019B 4791A10019B R

546810 MOTOR ASSEMBLY,OUTDOOR 4681AR1392X 4681AR1392X R

548490 ACCUMULATOR ASSEMBLY(MECH) 4848A20006L 4848A20006L R

552112 TUBE ASSEMBLY,CONDENSER IN 5211A11010A 5211A11010A R

552113 TUBE ASSEMBLY, CONDENSER OUT 5211A12001A 5211A12001A R

552116 TUBE ASSEMBLY, REVERSING AJR30111101 AJR30111101 R

552117 TUBE ASSEMBLY, SUCTION(OUTDOOR) AJR30125001 AJR30125001 R

554031 CONDENSER ASSEMBLY, BENDING 5403A20168A 5403A20168C R

559010 FAN ASSEMBLY, PROPELLER 5901A10033A 5901A10033A R

561410 COIL ASSEMBLY, REVERSING VALVE 3A02028Z - R

649950 CASE ASSEMBLY,CONTROL(OUTDOOR) 4995A00002H 4995A00002H R

668711-1 PWB(PCB) ASSEMBLY,MAIN(AC) 6871A20500B 6871A20500B R

668711-2 PWB(PCB) ASSEMBLY,MAIN(OUTDOOR) 6871A20479E 6871A20479E R

137213-1 PANEL ASSEMBLY, SIDE 3721A10110A 3721A10110A R

137213-2 PANEL ASSEMBLY, SIDE 3721A10111C 3721A10111C R

552203-1 VALVE,SERVICE 5220A20001K 5220A20001K R

552203-2 VALVE,SERVICE 2H02479J 2H02479J R

554160-1 COMPRESSOR 2520UHGK2AA 2520UHGK2AA R

554160-2 COMPRESSOR TBZ30111701 TBZ30111701 R

552204-1 DRAWING,ASSEMBLY(EEV COIL) 6877A20050A 6877A20050A R

552204-2 DRAWING,ASSEMBLY(EEV COIL) 6877A20050B 6877A20050B R

552204-3 DRAWING,ASSEMBLY(EEV COIL) 6877A20050C 6877A20050C R

W0CZZ-1 CAPACITOR,FILM,BOX 0CZZA20007Q 0CZZA20007Q R

W0CZZ-2 CAPACITOR,FILM,BOX 2H01451S 2H01451S R

567502 O.L.P 6750U-L048A 6750U-L048A R

DESCRIPTIONSVC

CODELOCATION

No.

Page 91: Multi Type Air Conditioner - SERVICE MANUAL

P/No.: MFL32351802

June, 2006

Printed in Korea