Multi-Story Fittings Cast Iron Multi-Story · 2020. 5. 27. · 3. Multi-Story Fittings. hank you for your interest in Charlotte Pipe and Foundry Starter Fittings. Charlotte Pipe and
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1
Multi-Story Fittings
APPLICATION GUIDE AND DIMENSIONAL CATALOG
Cast Iron Fitting Products for Multi-Story Applications
Revit® Drawings Available at www.charlottepipe.com
Download our Tech Tools App for dimensional info, tech calculators and more on your mobile device.
All detail drawings included in this manual can be downloaded as DWG or PDF documents at www.charlottepipe.com.
3
Multi-Story Fittings
Thank you for your interest in Charlotte Pipe and Foundry Starter Fittings. Charlotte Pipe and Foundry offers both Hubless and Service fittings for multi-story applications. Our fittings have been designed in cooperation with generations of commercial contractors to make commercial DWV instal-lations more efficient. Used in combination with thoughtful plumbing design, Starter Fittings will reduce the total number of fittings in an installation. They reduce the number of joints, minimize the complexity of distributing fittings on a job site, fit better within confined plumbing walls, and improve the overall quality of a job. This maximizes profitability for the installing contractor. Another user-friendly feature of our Starter Fittings is the ability to custom order vent and inlet positions to fit building needs. Charlotte Pipe products are proudly manufactured in the USA. Please contact Charlotte Pipe with any questions on the application of these fittings, comments or recommendations.
The Anatomy of a Starter Fitting
Revit® Drawings Available at www.charlottepipe.com
Charlotte Pipe and “You can't beat the system” are registered trademarks of Charlotte Pipe and Foundry Company.
4
Multi-Story Fittings
TYPICAL HIGH-RISE BUILDING INSTALLATION
All products manufactured by Charlotte Pipe and Foundry Company are proudly made in the U.S.A.
Multi-Story Hubless Fittings
4” HUBLESS CAST IRON PIPE DRAIN LINE
2” HUBLESS CAST IRON
2” HUBLESS CAST IRON PIPE VENT LINE
FINISHED FLOOR
CONTRACTOR SHALL USEPART NO. EZS 800R
CONTRACTOR SHALL USEPART NO. EZS 7L
4” HUBLESS CAST IRON PIPE DRAIN LINE2” HUBLESS CAST IRON
PIPE VENT LINE
2” HUBLESS CAST IRON
CONTRACTOR SHALL USEPART NO. EZS 800R
CONTRACTOR SHALL USEPART NO. EZS 7L
FINISHED FLOOR
FINISHED FLOOR
4” HUBLESS CAST IRON PIPE DRAIN LINE2” HUBLESS CAST IRON
PIPE VENT LINE
2” HUBLESS CAST IRON
CONTRACTOR SHALL USEPART NO. EZS 800R
P-TRAP(TYPICAL)
P-TRAP(TYPICAL)
P-TRAP(TYPICAL)
EZS 800 STACKED PERSPECTIVE
5
Multi-Story Fittings
Typical InstallationsEZS 700D
DOUBLE FLOOR MOUNT BACK OUTLET APPLICATIONEZS 700R
WALL MOUNT BACK OUTLET APPLICATION
6
Multi-Story Fittings
Typical InstallationsEZS 800D
DOUBLE FLOOR MOUNT BACK OUTLET APPLICATIONEZS 800R
WALL MOUNT BACK OUTLET APPLICATION
7
Multi-Story Fittings
Typical InstallationsEZS 800D
DOUBLE WALL MOUNT BACK OUTLET APPLICATION
8
Multi-Story Fittings
Typical InstallationsEZS 800L
FLOOR MOUNT BACK OUTLET APPLICATIONEZS 800R
FLOOR MOUNT BACK OUTLET APPLICATION
9
Multi-Story Fittings
*U.P.C. No. 611942 Size A C F Weight
04429 2 x 183⁄8 47⁄8 93⁄16 183⁄8 8.1
PART NO. EZS 72” Vent Cross-Over, Plain
(No Outlets)
EZS 2” Vent Cross-Over For use with EZS 50 through 800 Series Fittings
*U.P.C. No. 611942 Size A B C F Weight
04430 2 x 183⁄8 47⁄8 61⁄2 93⁄16 183⁄8 8.0
PART NO. EZS 7D2” Vent Cross-Over, Double
(2 Inlets)
*U.P.C. No. 611942 Size A B C F Weight
04431 2 x 183⁄8 47⁄8 61⁄2 93⁄16 183⁄8 8.2
PART NO. EZS 7L2” Vent Cross-Over with Left Hand Inlet
*U.P.C. No. 611942 Size A B C F Weight
04432 2 x 183⁄8 47⁄8 61⁄2 93⁄16 183⁄8 8.4
PART NO. EZS 7R2” Vent Cross-Over
with Right Hand Inlet
(Right Hand Cross-Over Illustrated)
With the vented end toward you, hold the fitting so that you are looking into its length with the curved side up. If the vent is on your left side, it is a Left Hand fitting. If the vent is on your right
side, it is a Right Hand fitting.
HOW TO DETERMINE RIGHT or LEFT HAND CROSS-OVER
Note: Our crossovers are designed for use with EZS starter fittings, that is for the vent and stack centerline
to be 61 ⁄2”
Note: VENT CROSS-OVER for use with EZS-50 through 800 Series fittings.
Specify Right, Left, Plain or Double.
Multi-Story Hubless Fittings
10
Multi-Story Fittings
EZS 7R 2” Vent Cross-Over
FINISHED FACEOF WALL CONTRACTOR SHALL USE
PART NO. EZS 7R2” VENT CROSS-OVER WITHRIGHT HAND INLET
PART NO. NH 458Vented Closet Tee with 2” Top Vent and 2” Side Inlet
(Left Hand or Right Hand; Designed for use below the floor; Fitting does not require a baffle)
(Photos Show Left Hand)
These No-Hub closet fittings can be ordered with Left hand, Right hand or Double closet inlets, and with 2” sanitary inlets at various heights on either side of the fitting. They can be ordered with an additional inlet (see illustrations) by adding a “1” after the first digit of the Series Number, i.e. 51, 110, 210, etc.
SINGLE FITTING LEFT HAND UNDER-SLAB - LEFT SIDE ELEVATION
INTEGRAL 2” VENT STACK FITTING
5-1/2”MIN.
CLOSET BEND PER REQUIREMENTS
INTEGRAL 2” INLET LEFT SIDE
25
Multi-Story Fittings
PART NO. EZS 100*16” Closet Fittings with 2” Inlets
(Double, Left Hand or Right Hand; Designed for use below the floor)
M & B dimensions must be measured from the bottom
of the fitting.
*When ordering please specify Double, Left or Right.
Part No. Size A B C D E M Weight
EZS 100D 4x16 163⁄4 5 41⁄2 61⁄2 51⁄2 5 22.0 N
EZS 100L 4x16 163⁄4 5 41⁄2 61⁄2 51⁄2 5 20.0 N
EZS 100R 4x16 163⁄4 5 41⁄2 61⁄2 51⁄2 5 21.1 N
N = non-stock item – contact customer service for availability.
Multi-Story Hubless Starter Fittings
(Photos Show Left Hand)
Size A B C D E F G Wt.
4x4x2x2x4x4 81⁄8 41⁄4 51⁄4 71⁄2 4 101⁄2 33⁄4 15.6
PART NO. NH 464Vented Closet Cross with 2” Top Vent
and 2” Side Inlet (Designed for use below the floor; Fitting has a baffle)
(Gray AreaIndicates Baffle)
(Right Hand Closet Fitting Illustrated)
To determine if whether a closet fitting is a right hand or left hand configuration, stand the fitting up with the closet inlet facing you. If the opening is on your left, it is a Left Hand fitting. If the opening is on your right, it is a Right Hand fitting. Right Hand and Left Hand configurations do not apply for Double fittings.
HOW TO DETERMINE RIGHT or LEFT HAND CLOSET FITTING
26
Multi-Story Fittings
PART NO. EZS 400*30” Closet Fittings with 2” Inlet
(Double, Left Hand or Right Hand; Designed for use in the floor)
M & B dimensions must be measured from the bottom
of the fitting.
*When ordering please specify Double, Left or Right.
**Double starter fitting has a baffle. Note: “O” dimension denotes the absence of the designated inlet.Note: Not designed for use with trim package.
**Double starter fitting has a baffle. Note: Not designed for use with trim package.
(Photo Shows Left Hand)(Photo Shows Left Hand) (Photo Shows Left Hand, Top View)
(Photo Shows Left Hand, Top View)
(Photo Shows Double, Top View)(Photo Shows Double, Top View)
35
Multi-Story Fittings
PART NO. EZS 22 Trim Package, Support Frame Assembly
(Weight capacity for the EZS 22 Support Frame is 500 pounds maximum.)
1—FRAME1—LEFT LEG1—RIGHT LEG1—SUPPORT LEG (used for single only)5—1⁄2” x 11⁄4” BOLTS5—1⁄2” FLAT WASHERS
EZS 22 Extended Leg (Left or Right)
EZS 22 Support Leg
(Illustration Shows Front of Frame) (Illustration Shows Front of Frame)(Illustration Shows Side of Frame)
(Illustration Shows Front View)
(Illustration Shows Side View)
(Illustration Shows Side View)
36
Multi-Story Fittings
PART NO. EZS 24 Trim Package, Wall-Hung Back-Outlet Assembly
(To be used with PART NO. EZS 22 Support Frame Assembly)
1—4” PVC Sch. 80 NIPPLE with TEST CAP1—BOWL GASKET4—5⁄8” x 12” RODS4—5⁄8” CHROME CAP NUTS8—5⁄8” JAM NUTS4—5⁄8” FLAT WASHERS4—5⁄8” FIBER WASHERS3—3⁄8” x 11⁄2” BOLTS FOR FACEPLATE3—3⁄8” FLAT WASHERS4—5⁄8” STAR WASHERS
Exploded View of Support Assembly Hardware
EZS 22 and EZS 24 Assemblies Illustrated
1. Identify the major components of the EZS 24 Trim Pack-age and EZS 22 Support Frame.
2. Secure EZS 22 Support Frame to installed starter fit-ting using 3⁄8” x 1 ½” bolts and 3⁄8” flat washers.
3. Secure right and left legs to the EZS 22 faceplate using ½” x 1 ¼” bolts and ½” flat washers in position shown to the right.
4. Adjust assembly to the desired height. Level and align the assembly.
5. Secure the feet of the EZS 22 Support Frame to the floor using the ½” x 1 ¼” bolts supplied.
6. Secure support leg. For double starter fittings, the sup-port leg is not required.
7. Secure 5⁄8” x 12” EZS 24 thread rods to faceplate ac-cording to EZS 22 faceplate.
8. Install EZS 24 threaded nipple to the EZS 700 or EZS 800 fitting.
EZS 22 and EZS 24 Installation Instructions
37
Multi-Story Fittings
PART NO. EZS 23Trim Package, Floor-Mounted Back-Outlet Assembly
(Note: Not to be used with PART NO. EZS 22 Support Frame Assembly)
1—4” PVC Sch. 80 NIPPLE with TEST CAP1—BOWL GASKET2—5⁄16” x 12” RODS2—5⁄16” HEX NUTS2—5⁄16” FLAT WASHERS2—5⁄16” CAP NUTS
PART NO. EZS 800D Typical Installation
EZS 800D NH 12EZS 9
EZS 38
42
18 EZS 14
NH 34
NH 28
Vent
EZS 16 EZS 7L NH 4Long
38
Multi-Story Fittings
Fixture Type CPF Fitting Support Frame Trim Package (If Applicable) (If Applicable)
➀ SV 1739 Left Hand Vented Closet Tee with 2” 45° Taps ➁ SV 1801 2x2x2 Tapped Harp Fitting ③ SV 83 5x2 Straight Tapped Tee ④ 5x10 SV Single Hub Pipe ➄ 4x10 SV Single Hub Pipe SV 206 4x4x18 Tapped Closet Bend with Southern Code Brass Plug
MULTI-STORY INSTALLATION
➀ SV 581 4x2x2 Double Sink Stack — 1770 ➁ SV 83 3x2 Straight Tapped Tee ③ 3x10 Single Hub Pipe ④ 4x10 Single Hub Pipe
MULTI-STORY INSTALLATION
Typical installation shows single back-outlet water closet and double-sink applications.
Multi-Story Service Fittings
All products manufactured by CharlottePipe and Foundry Company are proudlymade in the U.S.A.
41
Multi-Story Fittings
PART NO. SV 206Tapped Closet Bend with
Southern Code Brass Plug
Size A B Weight
31⁄2 x 4 x 4 x 18 18 4 17.4
Multi-Story Tapped Service Fittings
Size E’ G X Weight
2 x 11⁄2 213⁄16 61⁄4 8 6.4 2 x 2 31⁄16 61⁄4 8 6.7 3 x 2 39⁄16 7 9 9.0 4 x 2 41⁄16 7 9 11.6
PART NO. SV 91Sanitary Tapped Cross
Size E’ G X Weight
2 x 11⁄2 2 61⁄4 8 5.5 2 x 2 2 61⁄4 8 6.0 3 x 11⁄2 21⁄2 7 9 7.4 3 x 2 21⁄2 7 9 8.5 4 x 2 3 7 9 12.3 4 x 3 4 8 11 14.0 4 x 4 3 7 9 15.0 5 x 2 31⁄2 7 9 13.5 5 x 4 31⁄2 81⁄2 12 17.9 6 x 4 41⁄4 9 13 24.4
Size E’ G X Weight
2 x 11⁄2 213⁄16 61⁄4 8 6.0 2 x 2 31⁄16 61⁄4 8 5.8 3 x 11⁄2 35⁄16 7 9 8.0 3 x 2 39⁄16 7 9 8.1 4 x 11⁄2 313⁄16 7 9 10.3 4 x 2 41⁄16 7 9 11.7 4 x 3 41⁄16 8 11 13.6
PART NO. SV 83Straight Tapped Tee
PART NO. SV 84Sanitary Tapped Tee
Size E’ G X Weight
2 x 2 x 18 31⁄16 61⁄4 18 8.8
PART NO. SV 89Long Sanitary Tapped Tee
42
Multi-Story Fittings
PART NO. SV 982Tapped By-Pass Vent Fitting
Size A B C D E F Weight
2 x 2 18 10 61⁄2 31⁄2 3 51⁄4 11.3
PART NO. SV 566Tapped Long Sweep Tee
Size A B C D Weight
2 x 2 51⁄2 31⁄8 4 55⁄8 6.2
(Side View)
(Top View)
PART NO. SV 985Tapped Bath Vent Wye
Size A B C D Weight
2 x 2 41⁄16 5 31⁄4 21⁄2 8.4
(Right Hand Closet Fitting Illustrated)
To determine if whether a closet fitting is a right hand or left hand configuration, stand the fitting up with the closet inlet facing you. If the opening is on your left, it is a Left Hand fitting. If the opening is on your right, it is a Right Hand fitting. Right Hand and Left Hand configurations do not apply for Double fittings.
HOW TO DETERMINE RIGHT or LEFT HAND CLOSET FITTING
43
Multi-Story Fittings
(Photo Shows Left Hand, Top View)
PART NO. SV 458Vented Closet Tee with 2” Top Vent
and 2” Extended Side Inlet(Right Hand or Left Hand; Designed for use below the floor;
THREADED NIPPLE5/16” THREADED ROD - (TAP IN FITTING)
52
Multi-Story Fittings
PART NO. SV 974RRight Hand Starter Fitting with 4” Hub and
2” Tapped “A” Side Inlet(Designed for use below or in the floor
with bottom-outlet water closets)
Size A B C D E F X Weight
4 with A inlets 61⁄2 61⁄2 61⁄2 41⁄16 4 4 25 39.2
PART NO. SV 974LLeft Hand Starter Fitting with 4” Hub and
2” Tapped “A” Side Inlet(Designed for use below or in the floor
with bottom-outlet water closets)
Size A B C D E F X Weight
4 with A inlets 61⁄2 61⁄2 61⁄2 4 4 41⁄16 25 39.7
INLETA
6 1⁄2
INLETA
6 1⁄2
(Top View) (Top View)
(Side View) (Side View)
53
Multi-Story Fittings
Size A B C D X Weight
4 with A & B inlets 61⁄2 18 61⁄2 61⁄2 25 43.7
PART NO. SV 974LLeft Hand Starter Fitting with 4” Hub and
2” Tapped “A” and “B” Side Inlets(Designed for use below or in the floor
with bottom-outlet water closets)
Size A B C D X Weight
4 with A & B inlets 61⁄2 18 61⁄2 61⁄2 25 46.2
PART NO. SV 974RRight Hand Starter Fitting with 4” Hub and
2” Tapped “A” and “B” Side Inlets(Designed for use below or in the floor
with bottom-outlet water closets)
INLET A B 61⁄2 18
NOTES:1. Single Vertical R.H. Offset Floor Starter Fitting2. 4” Stack with 2” Vent & Inlets
INLET A B 61⁄2 18
FLOOR/CEILING
FLOOR/CEILING
NOTES:1. Single Vertical R.H. Offset Floor Starter Fitting2. 4” Stack with 2” Vent & Inlets
54
Multi-Story Fittings
PART NO. SV 975Double Starter Fitting with 4” Tap and
2” Tapped “A” Side Inlets(Designed for use above the floor with back-outlet
water closets; Fitting has a baffle)
Size A B C D E F X Weight
4 91⁄2 61⁄2 4 4 4 41⁄16 25 42.5
Cast Iron pipe and fittings are only intended for DWV (drain, waste and vent) non-pressure applications. Using cast iron pipe and fittings in pressure applications could result in explosive failures, causing serious injury or death or property damage.
• NEVER test with or transport/store compressed air or gas in Cast Iron pipe or fittings.
• NEVER test Cast Iron pipe or fittings with compressed air or gas.
• ONLY use Cast Iron pipe and fittings for drain, waste and vent or sanitary sewer applications.
Testing with or use of compressed air or gas in Cast Iron pipe or fittings can result in explosive failures and cause severe injury or death.
Unsecured piping can fall and cause serious injury. Always properly support and secure piping to help prevent injury.
Always wear protective clothing, including hard hats, during installation.
INLETA
9 1⁄2
(Top View)
(Gray AreaIndicates Baffle)
(Side View)
55
Multi-Story Fittings
PART NO. SV 976Double Starter Fitting with 4” Hub and
2” Tapped “A” Side Inlet(Designed for use below or in the floor with
bottom-outlet water closets; Fitting has a baffle)
Size A B C D E F X Weight
4 with A inlets 61⁄2 61⁄2 61⁄2 4 4 41⁄16 25 50.8 Size A B C D E X Weight
4 with A & B inlets 61⁄2 18 61⁄2 61⁄2 41⁄16 25 56.6
PART NO. SV 976Double Starter Fitting with 4” Hub and
2” Tapped “A” and “B” Side Inlets(Designed for use below or in the floor with
bottom-outlet water closets; Fitting has a baffle)
(Top View)
INLETA
6 1⁄2
INLET A B 61⁄2 18
(Gray AreaIndicates Baffle) (Gray Area
Indicates Baffle)
(Side View)
56
Multi-Story Fittings
Service Weight Application Index
Fixture Type CPF Fitting Support Frame Trim Package (If Applicable) (If Applicable)
PART NO. SV 973R Right Hand Starter Fitting with 4” Tap
PART NO. SV 973L Left Hand Starter Fitting with 4” Tap
PART NO. SV 975 Double Starter Fitting with 4” Tap
Minimum Space Requirements for Multi-Story Service Starter FittingsTapped Service Fitting Illustrations Shown with EZS 22 Support Frame and EZS 24 Trim Package
11” 16”
58
Multi-Story Fittings
Charlotte and Charlotte Pipe are registered trademarks of Charlotte Pipe and Foundry Company.
PO Box 35430 Charlotte, NC 28235 USA 704/348-6450 800/572-4199 FAX 800/553-1605www.charlottepipe.com
Limited Warranty
• NEVER test with or transport/store compressed air or gas in PVC / ABS / CPVC / Cast Iron pipe or fittings.
• NEVER test PVC / ABS / CPVC / Cast Iron pipe or fittings with compressed air or gas, or air over water boosters.
• ONLY use PVC / ABS / CPVC / Cast Iron pipe or fittings for water or approved chemicals.
• Refer to warnings on PPFA’s website and ASTM D 1785.
Testing with or use of compressed air or gas in PVC / ABS / CPVC / Cast Iron pipe or fittings can result in explosive failures and cause severe injury or death.
Charlotte Pipe and Foundry Company® (Charlotte Pipe®) Products are warranted to be free from manufacturing defects and to conform to currently applicable ASTM standards for a period of five (5) years from date of delivery. Buyer’s remedy for breach of this warranty is limited to replacement of, or credit for, the defective product. This warranty excludes any expense for removal or reinstallation of any defective product and any other incidental, consequential, or punitive damages. This limited warranty is the only warranty made by seller and is expressly in lieu of all other warranties, express and implied, including any warranties of merchantability and fitness for a particular purpose. No statement, conduct or description by Charlotte Pipe or its representative, in addition to or beyond this Limited Warranty, shall constitute a warranty. This Limited Warranty may only be modified in writing signed by an officer of Charlotte Pipe.
This Limited Warranty will not apply if:
1) The Products are used for purposes other than their intended purpose as defined by local plumbing and building codes, and the applicable ASTM standard.
2) The Products are not installed in good and workmanlike manner consistent with normal industry standards; installed in compliance with the latest instructions published by Charlotte Pipe and good plumbing practices; and installed in conformance with all applicable plumbing, fire and building code requirements.
3) This limited warranty does not apply when the products of Charlotte Pipe are used with the products of other manufacturers that do not meet the applicable ASTM or CISPI standards or that are not marked in a manner to indicate the entity that manufactured them.
4) In hubless cast iron installations, this warranty will not apply if products are joined with unshielded hubless couplings. Charlotte Pipe requires that its hubless cast iron pipe and fittings be joined only with shielded hubless couplings manufactured in accordance with CISPI 310, ASTM C 1277 and certified by NSF® International or with Heavy Duty Couplings meeting ASTM C 1540.
5) The Products fail due to defects or deficiencies in design, engineering, or installation of the piping system of which they are a part.
6) The Products have been the subject of modification; misuse; misapplication; improper maintenance or repair; damage caused by the fault or negligence of anyone other than Charlotte Pipe; or any other act or event beyond the control of Charlotte Pipe.
7) The Products fail due to the freezing of water in the Products.
8) The Products fail due to contact with chemical agents, fire stopping materials, thread sealant, plasticized vinyl products, or other aggressive chemical agents that are not compatible.
9) Pipe outlets, sound attenuation systems or other devices are permanently attached to the surface of Charlotte® PVC, ABS or CPVC products with solvent cement or adhesive glue.
Charlotte Pipe products are manufactured to the applicable ASTM or CISPI standard. Charlotte Pipe and Foundry cannot accept responsibility for the performance, dimensional accuracy, or compatibility of pipe, fittings, gaskets, or couplings not manufactured or sold by Charlotte Pipe and Foundry.
Any Charlotte Pipe products alleged to be defective must be made available to Charlotte Pipe at the following address for verification, inspection and determination of cause:
Charlotte Pipe and Foundry CompanyAttention: Technical Services
2109 Randolph RoadCharlotte, North Carolina 28207
Purchaser must obtain a return materials authorization and instructions for return shipment to Charlotte Pipe of any product claimed defective or shipped in error.Any Charlotte Pipe product proved to be defective in manufacture will be replaced F.O.B. point of original delivery, or credit will be issued, at the discretion of Charlotte Pipe.
4/24/15
59
Multi-Story Fittings
Notes
PO BOX 35430
CHARLOTTE
NORTH CAROLINA 28235
PHONE (704) 348-6450
(800) 438-6091
FAX (800) 553-1605
WWW.CHARLOTTEPIPE.COM