88 SELECTION Choose from seven types of indoor units and twelve outdoor units that can run up to six indoor units each. Create the system that best matches room shapes and number of rooms. SELECT INDOOR UNITS Select the indoor unit to be installed in each room. Wall-mounted Floor-standing Cassette Ceiling-suspended Ceiling-concealed SELECT OUTDOOR UNITS Select the best outdoor unit based on the number of indoor units and overall system capacity required. 2-port Connect up to 2 indoor units 3-port Connect up to 3 indoor units 4-port Connect up to 4 indoor units 5-port Connect up to 5 indoor units 6-port Connect up to 6 indoor units 4-port Connect up to 4 indoor units CHECK SYSTEM COMPATIBILITY Possible combinations depends on the outdoor unit chosen. Please check the following points. Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with the outdoor unit selected. (Indoor units not listed in the table cannot be used.) Refer to the “Combination Table” to check if the capacity combination of the indoor unit selected is connectable. (Combinations not listed cannot be connected.) Check Indoor Unit Capacity Combination If the desired combination cannot be found, please change either the indoor or outdoor unit to match one of the combinations shown in the tables. Check Indoor Units MXZ-5E102VA MXZ-6D122VA MXZ-4E72VA MXZ-4E83VA STEP 1 STEP 2 STEP 3 MXZ-4E83VAHZ 2-port Connect up to 2 indoor units MXZ-2E53VAHZ MSZ-FH MSZ-EF MSZ-SF (15 • 20) MSZ-GF MSZ-SF (25-50) MFZ-KJ SLZ-KF PLA MLZ-KA PCA SEZ-KD PEAD HYPER HEATING* *Refer to page101 and page 109 for detailed information. MXZ-2D33VA(2) MXZ-2D42VA(2) MXZ-2D53VA(H) MXZ-3E54VA MXZ-3E68VA
3
Embed
MULTI - Narkissos Aircon Limassol Cyprus · MXZ-5E102VA M SZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF22VE2 + MSZ-EF22VE2 + MSZ-EF22VE2 *5 Power input and operating current (max) ƒgures are
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
88
SERIES
SELECTIONChoose from seven types of indoor units and twelve outdoor units that can run up to six indoor units each. Create the system that best matches room shapes and number of rooms.
MULTISPLIT
SELECT INDOOR UNITSSelect the indoor unit to be installed in each room.
SELECT OUTDOOR UNITSSelect the best outdoor unit based on the number of indoor units and overall system capacity required.
2-port Connect up to 2 indoor units 3-port Connect up to 3 indoor units 4-port Connect up to 4 indoor units
5-port Connect up to 5 indoor units 6-port Connect up to 6 indoor units 4-port Connect up to 4 indoor units
CHECK SYSTEM COMPATIBILITYPossible combinations depends on the outdoor unit chosen. Please check the following points.
Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with the outdoor unit selected. (Indoor units not listed in the table cannot be used.)
Refer to the “Combination Table” to check if the capacity combination of the indoor unit selected is connectable. (Combinations not listed cannot be connected.)
Check Indoor Unit CapacityCombination
If the desired combination cannot be found, please change either the indoor or outdoor unit to match one of the combinations shown in the tables.
Check Indoor Units
MXZ-5E102VA MXZ-6D122VA
MXZ-4E72VA MXZ-4E83VA
STEP 1
STEP 2
STEP 3
MXZ-4E83VAHZ
2-port Connect up to 2 indoor units
MXZ-2E53VAHZ
MSZ-FH
MSZ-EF
MSZ-SF (15 •20)
MSZ-GF
MSZ-SF (25-50)
MFZ-KJ
SLZ-KF
PLA
MLZ-KA
PCA
SEZ-KD
PEAD
HYPER HEATING*
*Refer to page101 and page 109 for detailed information.
MXZ-2D33VA(2)MXZ-2D42VA(2)MXZ-2D53VA(H)
MXZ-3E54VAMXZ-3E68VA
89
MXZ SERIESAdvancements in the MXZ Series include e�ciency and exibility in system expansion capabilities. The best solution when requiring multi-system air conditioning needs.
The MXZ Series o�ers a ten-system line-up to choose from, ranging between 3.3 and 12.2kW. All of them are compatible with speci�c M, S and P series indoor units. A single outdoor unit can handle a wide range of building layouts.
2-port 3-port 4-port 4-port 5-port 6-port
MXZ-2D33VA(2)MXZ-2D42VA(2)MXZ-2D53VA (H)
MXZ-4E83VAMXZ-5E102VA
MXZ-3E54VAMXZ-3E68VAMXZ-4E72VA
MXZ-6D122VA
MXZ-6D122VA system
Simply press a single button to con�rm if wiring and piping are properly connected. Wiring errors are corrected automatically when discovered. This eliminates the need to con�rm complicated wiring connections when expanding the system. (For details, refer to the outdoor unit instal-lation manual.)* Function cannot be used when the outdoor temperature is below 0°C.
The correction process requires 10–20 minutes to complete and must be conducted with the unit set to the “Cooling” mode.
Ampere Limit Adjustment*(4E83/5E102/6D122)
Dipswitch settings can be used to adjust the maximum electrical current for operation. This function is highly recommended for managing energy costs. (For details, refer to the outdoor unit installation manual.)* Maximum capacity is lowered with the use of this function.
Operation Lock
To accommodate speci�c use applications, cooling or heating operation can be speci�ed when setting the control board of the outdoor unit. A convenient option when a system needs to be con�gured for exclusive cooling or heating service. (For details, refer to the outdoor unit installa-tion manual.)
Type (Inverter Multi - Split Heat Pump)Indoor UnitOutdoor UnitRefrigerant
Power Supply
3.31.1 - 3.8
0.903.32115.5A
4.01.0 - 4.1
0.962.72.12.41.70.69264.1A+
10.0
3232.933.749506310
6.35 × 29.52 × 2
201510 20
–10 ~ +46–15 ~ +24
4.21.1 - 4.4
1.00
4.22196.7
A++
4.51.0 - 4.8
0.933.22.73.02.30.5
10654.2
A+
12.2
3727.733.3465160
15 6.35 × 2 9.52 × 2
3020
15 (10)*3
20 –10 ~ +46–15 ~ +24
5.31.1 - 5.6
1.545.32627.1
A++
6.41.0 - 7.0
1.704.53.74.03.30.8
15074.2A+
12.2
3732.933.350536415
6.35 × 29.52 × 2
3020
15 (10)*3
20–10 ~ +46–15 ~ +24
5.31.1 - 5.6
1.545.32627.1
A++
6.41.0 - 7.0
1.704.53.64.03.00.9
15464.1A+
12.2
3832.933.350536415
6.35 × 29.52 × 2
3020
15 (10)*3
20–10 ~ +46–20 ~ +24
5.42.9 - 6.8
1.35
5.42956.4
A++
7.02.6 - 9.0
1.595.0
4.004.493.171.0017514.0
A+
18.0
5842.143.0505364
256.35 × 39.52 × 3
5025
15 (10)*3
40–10 ~ +46–15 ~ +24
6.82.9 - 8.4
2.196.84255.6A+
8.62.6 - 10.6
2.386.85.46.04.41.4
24663.9A
18.0
5842.143.050536425
6.35 × 39.52 × 3
6025
15 (10)*3
40–10 ~ +46–15 ~ +24
7.23.7 - 8.8
2.257.24435.7A+
8.63.4 - 10.7
2.287.05.66.24.71.4
25163.9A
18.0
5942.143.050536425
6.35 × 412.7×1+9.52×3
6025
15 (10)*3
40–10 ~ +46–15 ~ +24
8.33.7 - 9.2
2.448.34606.3
A++
9.33.4 - 11.6
2.008.77.17.86.01.6
28844.2A+
21.4
6255.655.649516125
6.35 × 412.7×1+9.52×3
7025
15 (10)*3
25–10 ~ +46–15 ~ +24
10.23.9 - 11.0
3.1510.25376.6
A++
10.54.1 - 14.0
2.348.97.37.96.31.6
29584.2A+
21.4
6365.168.052566525
6.35 × 512.7×1+9.52×4
8025
15 (10)*3
0–10 ~ +46–15 ~ +24
Up to 3 Indoor Units Up to 4 Indoor Units Up to 5 Indoor Units
Up to 6 Indoor Units
Cooling
Heating
Operating Current (max)*5
Outdoor Unit
Ext. Piping
Guaranteed Operating Range [Outdoor]
SourceOutdoor (V/Phase/Hz)Capacity
Input*5
EER*6
Capacity
Input*5
COP*6
DimensionsWeightAir Volume
Sound Level (SPL)
Sound Level (PWL)Breaker SizeDiameter
Total Piping Length (max)Each Indoor Unit Piping Length (max)
Rated
Rated
EEL RankRated
Rated
EEL Rank
H × W × D
CoolingHeatingCooling
CoolingHeating
Liquid
CoolingHeating
kW
kW
Min - Max kW
kWMin - Max kW
kW
A
mmkg
m3/minm3/mindB(A)dB(A)dB(A)
Amm
Gas mmmm
Max. Height mChargeless Length m
oCoC
R410A*1
Outdoor power supply230 / Single / 50
Please refer to (*5)
MXZ-6D122VA
Type (Inverter Multi - Split Heat Pump)Indoor UnitOutdoor UnitRefrigerant
Power Supply
12.23.5 - 13.5
3.663.33
A14.0
3.5 - 16.53.314.23
A26.8
1048 - 950 - 33088
63.077.055576932
6.35 × 612.7×1+9.52×5
8025
15 (10)*3
30–10 ~ +46–15 ~ +24
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant �uid with a GWP equal to 1975. This means that if 1kg of this refrigerant �uid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.*3 If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.*4 EER/COP, EEL rank, SEER/SCOP values and energy e�ciency class are measured
*5 Power input and operating current (max) �gures are for outdoor unit only*6 EER/COP, EEL rank, values and energy e�ciency class are measured
when connected to the indoor units listed below.MXZ-6D122VA MSZ-EF22VE × 6
N: Please refer to the NOTE below.
INVERTER MULTIMXZ SERIES
Please fill out the requested informationPlease fill out the requested information
NOTEWhen connecting the MFZ-KJ series indoor unit(s) to this outdoor unit, charge additional refrigerant according to the instructions in the diagram below.
Not available (Only one MFZ-KJ series indoor unit can be connected.)
MSZ-FH
MLZ-KA
MSZ-SF
MSZ-EF
SLZ-KF
MFZ-KJ
4E83-6D 3D-4D72
Number of MFZ-KJ should be one or two when connected to MXZ-4D72VA. If three and more MFZ-KJ are connected, use other outdoor units, such as MXZ-3D68VA and MXZ-4E83VA.
90
MXZ SERIESAdvancements in the MXZ Series include e�ciency and exibility in system expansion capabilities. The best solution when requiring multi-system air conditioning needs.
The MXZ Series o�ers a ten-system line-up to choose from, ranging between 3.3 and 12.2kW. All of them are compatible with speci�c M, S and P series indoor units. A single outdoor unit can handle a wide range of building layouts.
2-port 3-port 4-port 4-port 5-port 6-port
MXZ-2D33VA(2)MXZ-2D42VA(2)MXZ-2D53VA (H)
MXZ-4E83VAMXZ-5E102VA
MXZ-3E54VAMXZ-3E68VAMXZ-4E72VA
MXZ-6D122VA
MXZ-6D122VA system
Simply press a single button to con�rm if wiring and piping are properly connected. Wiring errors are corrected automatically when discovered. This eliminates the need to con�rm complicated wiring connections when expanding the system. (For details, refer to the outdoor unit instal-lation manual.)* Function cannot be used when the outdoor temperature is below 0°C.
The correction process requires 10–20 minutes to complete and must be conducted with the unit set to the “Cooling” mode.
Ampere Limit Adjustment*(4E83/5E102/6D122)
Dipswitch settings can be used to adjust the maximum electrical current for operation. This function is highly recommended for managing energy costs. (For details, refer to the outdoor unit installation manual.)* Maximum capacity is lowered with the use of this function.
Operation Lock
To accommodate speci�c use applications, cooling or heating operation can be speci�ed when setting the control board of the outdoor unit. A convenient option when a system needs to be con�gured for exclusive cooling or heating service. (For details, refer to the outdoor unit installa-tion manual.)
Type (Inverter Multi - Split Heat Pump)Indoor UnitOutdoor UnitRefrigerant
Power Supply
3.31.1 - 3.8
0.903.32115.5A
4.01.0 - 4.1
0.962.72.12.41.70.69264.1A+
10.0
3232.933.749506310
6.35 × 29.52 × 2
201510 20
–10 ~ +46–15 ~ +24
4.21.1 - 4.4
1.00
4.22196.7
A++
4.51.0 - 4.8
0.933.22.73.02.30.5
10654.2
A+
12.2
3727.733.3465160
15 6.35 × 2 9.52 × 2
3020
15 (10)*3
20 –10 ~ +46–15 ~ +24
5.31.1 - 5.6
1.545.32627.1
A++
6.41.0 - 7.0
1.704.53.74.03.30.8
15074.2A+
12.2
3732.933.350536415
6.35 × 29.52 × 2
3020
15 (10)*3
20–10 ~ +46–15 ~ +24
5.31.1 - 5.6
1.545.32627.1
A++
6.41.0 - 7.0
1.704.53.64.03.00.9
15464.1A+
12.2
3832.933.350536415
6.35 × 29.52 × 2
3020
15 (10)*3
20–10 ~ +46–20 ~ +24
5.42.9 - 6.8
1.35
5.42956.4
A++
7.02.6 - 9.0
1.595.0
4.004.493.171.0017514.0
A+
18.0
5842.143.0505364
256.35 × 39.52 × 3
5025
15 (10)*3
40–10 ~ +46–15 ~ +24
6.82.9 - 8.4
2.196.84255.6A+
8.62.6 - 10.6
2.386.85.46.04.41.4
24663.9A
18.0
5842.143.050536425
6.35 × 39.52 × 3
6025
15 (10)*3
40–10 ~ +46–15 ~ +24
7.23.7 - 8.8
2.257.24435.7A+
8.63.4 - 10.7
2.287.05.66.24.71.4
25163.9A
18.0
5942.143.050536425
6.35 × 412.7×1+9.52×3
6025
15 (10)*3
40–10 ~ +46–15 ~ +24
8.33.7 - 9.2
2.448.34606.3
A++
9.33.4 - 11.6
2.008.77.17.86.01.6
28844.2A+
21.4
6255.655.649516125
6.35 × 412.7×1+9.52×3
7025
15 (10)*3
25–10 ~ +46–15 ~ +24
10.23.9 - 11.0
3.1510.25376.6
A++
10.54.1 - 14.0
2.348.97.37.96.31.6
29584.2A+
21.4
6365.168.052566525
6.35 × 512.7×1+9.52×4
8025
15 (10)*3
0–10 ~ +46–15 ~ +24
Up to 3 Indoor Units Up to 4 Indoor Units Up to 5 Indoor Units
Up to 6 Indoor Units
Cooling
Heating
Operating Current (max)*5
Outdoor Unit
Ext. Piping
Guaranteed Operating Range [Outdoor]
SourceOutdoor (V/Phase/Hz)Capacity
Input*5
EER*6
Capacity
Input*5
COP*6
DimensionsWeightAir Volume
Sound Level (SPL)
Sound Level (PWL)Breaker SizeDiameter
Total Piping Length (max)Each Indoor Unit Piping Length (max)
Rated
Rated
EEL RankRated
Rated
EEL Rank
H × W × D
CoolingHeatingCooling
CoolingHeating
Liquid
CoolingHeating
kW
kW
Min - Max kW
kWMin - Max kW
kW
A
mmkg
m3/minm3/mindB(A)dB(A)dB(A)
Amm
Gas mmmm
Max. Height mChargeless Length m
oCoC
R410A*1
Outdoor power supply230 / Single / 50
Please refer to (*5)
MXZ-6D122VA
Type (Inverter Multi - Split Heat Pump)Indoor UnitOutdoor UnitRefrigerant
Power Supply
12.23.5 - 13.5
3.663.33
A14.0
3.5 - 16.53.314.23
A26.8
1048 - 950 - 33088
63.077.055576932
6.35 × 612.7×1+9.52×5
8025
15 (10)*3
30–10 ~ +46–15 ~ +24
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant �uid with a GWP equal to 1975. This means that if 1kg of this refrigerant �uid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.*3 If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.*4 EER/COP, EEL rank, SEER/SCOP values and energy e�ciency class are measured
*5 Power input and operating current (max) �gures are for outdoor unit only*6 EER/COP, EEL rank, values and energy e�ciency class are measured
when connected to the indoor units listed below.MXZ-6D122VA MSZ-EF22VE × 6
N: Please refer to the NOTE below.
INVERTER MULTIMXZ SERIES
Please fill out the requested informationPlease fill out the requested information
NOTEWhen connecting the MFZ-KJ series indoor unit(s) to this outdoor unit, charge additional refrigerant according to the instructions in the diagram below.
Not available (Only one MFZ-KJ series indoor unit can be connected.)
MSZ-FH
MLZ-KA
MSZ-SF
MSZ-EF
SLZ-KF
MFZ-KJ
4E83-6D 3D-4D72
Number of MFZ-KJ should be one or two when connected to MXZ-4D72VA. If three and more MFZ-KJ are connected, use other outdoor units, such as MXZ-3D68VA and MXZ-4E83VA.