Multi-functional Flow Control Valve for Water Treatment Systems Hankscraft Runxin RevV20 Instruction Manual Please read this manual in detail before using the valve and keep it in a safe place for future reference.
37

Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

Mar 23, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

Multi-functional Flow Control Valve for Water Treatment SystemsHankscraft Runxin RevV20

Instruction Manual

Please read this manual in detail before using the valve and keep it in a safe place for future reference.

landres
Typewritten Text
Page 2: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

Before the valve is put into use, please fill in the below content.

Softener System Configuration Tank Size: Dia. in/mm, Height in/mm; Resin Volume ft3/L; Brine Tank Capacity L; Hardness of Raw Water grains/mmol/L; Pressure of Inlet Water psi/MPa; Control Valve Model ; Serial Number ; (13 digit number found on valve body) Specification of Drain Line Flow Control ; Injector No. ; Injector Color ; Water Source: Ground-water□ Filtered Ground-water □Tap Water □ other .

Quick conversion table 1 inch 25.4 mm 1 ft3 (of resin) 28.32 L 1 kg 2.2 lbs. 1 gal 3.79 L 1 m3/h (per hour) 4.4 gal/m (per minute) 1 gpg 17.1 mg/L or (ppm)

Parameter Settings

● If there are no special requirement(s) when the product is purchased, the #3 drain line flow control and #3 injector (yellow), is used for standard configuration.

Parameter Unit Factory Default Actual Value

Control Mode A-01 (02, 03, 04) A-01 Water Treatment Capacity (Meter type) m3 80 Service Days (Time clock type, by days) D. 03 Service Hours (Time clock type, by hours) Hr. 20 Regeneration Time Hr:Min 02∶00 Backwash Time Min. 10 Brine & Slow Rinse Time Min. 60 Brine Refill Time Min. 05 Fast Rinse Time Min. 10 Interval Regeneration Days D. 30 Output Mode b-01 (b-02) b-01

landres
Typewritten Text
landres
Typewritten Text
landres
Typewritten Text
Hankscraft Runxin RevV20 Valve Manual
landres
Typewritten Text
landres
Typewritten Text
landres
Typewritten Text
landres
Typewritten Text
landres
Typewritten Text
landres
Typewritten Text
Page 3: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

I

Notice ................................................................................................... 1. Product Overview ........................................................................... 2 1.1. Main Application & Applicability.................................................... 2 1.2. Product Characteristics ............................................................... 3 1.3. Service Condition ........................................................................ 5 1.4. Product Structure and Technical Parameters ............................... 6 1.5. Installation ................................................................................... 7 2. Basic Setting & Usage .................................................................. 10 2.1. The Function of PC Board ......................................................... 10 2.2. Basic Setting & Usage ............................................................... 11 3. Applications .................................................................................. 14 3.1. Flow Chart ................................................................................. 14 3.2. The Function and Connection of PC Board ................................ 15 A. Signal Output Connector .............................................................. 16 B. Interlock ....................................................................................... 18 C. Pressure Relief Output ................................................................. 19 D. Remote Handling Connector ........................................................ 19 E. Interlock System .......................................................................... 19 F. Series System .............................................................................. 20 3.3. System Configuration and Flow Rate Curve .............................. 20 3.4. Parameter settlement ................................................................ 21 3.5. Parameter Enquiry and Setting .................................................. 23 3.6. Trial Running ............................................................................. 26 3.7. Trouble-shooting ........................................................................ 28 3.8. Assembly & Parts ...................................................................... 31

Hankscraft Runxin RevV20 Valve Manual

Page 4: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

2

Preface Thank you for choosing this Hankscraft Runxin water softening system for your water treatment needs. Please read this manual carefully before attempting to use the system for the first time, and ALWAYS adhere to all safety and operating instructions. Doing so will protect your warranty and help keep your system running and operating safely and effectively.

***Before installing, read through this manual thoroughly. Failure to use this product

within the described conditions may void the warranty***

All plumbing and electrical work should be performed by an accredited professional to ensure all local, municipal, state, and federal guidelines are met.

Do not use the control valve with water that is unsafe or of unknown quality. This system does not sanitize or disinfect.

Do not use the brine tube, injector body, or other connectors on the RevV valve as a handle to carry the system.

Ensure there is salt in the brine tank at all times when this valve is used for softening. The brine tank should contain clean water and pellet softening salt only, at least 99.5% pure. The use of small grain or solar salt is not recommended.

When there is moderate to high turbidity, a filter should be installed before the water softening system on the inlet side.

If the water pressure exceeds 120psi, a pressure reducing valve must be installed before the water inlet. If the water pressure exceeds 80 psi, installing a pressure reducing valve before the water inlet is highly recommended. If the water pressure is under 21psi, a booster pump must be installed before the water inlet.

Replacement parts for the RevV valve should only be purchased through Hankscraft resellers. Electrical components such as transformers are specific to the RevV valve from Hankscraft.

Regular interval monitoring of the water quality and work environment is recommended to insure proper operation of the valve and system.

1. Product Overview 1.1. Main Application & Applicability

Used for softening, demineralization, or filtration of water treatment systems RevV 20 (A & B), suitable for:

Ion exchange equipment, with raw water hardness ≤ 6.5mmol/L. Boiler water softening system RO pretreatment softening system, etc.

Hankscraft Runxin RevV20 Valve Manual

landres
Typewritten Text
Page 5: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

3

1.2. Product Characteristics

Overview The advanced design incorporates a microcomputer control that analyzes real-world operating

conditions and performs regeneration automatically. This unique control valve features highly polished, patented ceramic discs. The design incorporates one fixed and one moving disc, which rotates through positions to align channels creating five different fluid pathways. These five pathways, or stages, are: Service, Backwash, Brine & Slow Rinse, Brine Refill, and Fast Rinse. Two Installation Options

Use side-mounted connector to change the valve from a top-mounted to side-mounted system.

Brine Refill Controlled By Electronic Ball Valve During service, electronic ball valve will trigger during the brine refill.

Manual Function Regeneration can be prompted by pressing at any time.

Extended Power Outage If there is a power outage of more than 72 hours (3 days), the time of day indicator “” will

flash to remind the end user to reset the current time of day. The other set parameters do not need to be reset. The system will resume working after power is restored. LED Dynamic Screen Display Moving (green) display bar indicates the control valve is in service, otherwise, it is in the

regeneration cycle. Buttons Lock If the display board is not in use for more than 1 minute the buttons will lock. A light indicating

this will appear. Before operating again press and hold the “ ” and “ ” buttons for 5 seconds to unlock. This function can deter unintended operation.

Program Model Selection Press and hold “ ” and “ ” buttons for 2 seconds, all the icons will light up, indicating access

to the model setting interface. Press “ ” or “ ” to navigate to specific model, then press to save the setting chosen, after reconnecting the power, the model will be visible on the display board. Interlock Function The interlock function is designed to have only one valve in regeneration, at a time, while

multiple other valves are in service in a parallel valve system. In multi-step treatment systems such as RO pre-treatment, when several valves are in series, there is only one valve in regeneration or washing to ensure product water at all times.(Application refer to Figure 3-9)

All Parameters Can Be Modified Depending on the water quality and usage, the parameters in the system can be adjusted.

Hankscraft Runxin RevV20 Valve Manual

Page 6: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

4

Signal Output There is a signal output connector on the main control board. This connector is designed to

control external devices (Refer to Figure from Figure3-1 to Figure 3-8).

b-01 and b-02 output modes: b-01: a signal that is sent through the entire duration of cycles during regeneration. In this mode, the signal can be sent once per cycle; b-02 Mode: the signal is sent at the end of one cycle and at the beginning of another. In this mode, the signal is sent five times per one complete cycle.

Remote Handling Connector This valve has a remote handling connector. An external device can determine when water

quality is below desirable levels. When this occurs, the valve has the capability to respond to a remote signal and regenerate. (Application refer to Figure3-11)

Pressure Relief Output The valve will cut off feed water to the drain line when it switches in regeneration cycles (Same

as signal output b-02). Some water treatment system, e.g. Deep Well, one booster pump is installed on the inlet to increase the system feed water pressure; this cut-off will prevent pressure on inlet from rising too quickly, potentially preventing damage to the valve. Pressure Relief Output can be used to avoid this problem. (For application refer to Figure3-10) Meter type(s) that can be selected (RevV 20) Model Name Instruction

A-01 Meter Delayed Regeneration happens when the capacity reaches zero and the preset time of regeneration is reached.

A-02 Meter Immediate Regeneration happens when the capacity reaches zero.

A-03 Intelligent Meter Delayed

Meter Delayed Regeneration type, but by setting Resin Volume, Feed Water Hardness, Regeneration Factor, the controller will calculate the System Capacity. Regeneration mode is the same as A-01.

A-04 Intelligent Meter Immediate

Meter Immediately Regeneration Type, but by setting Resin Volume, Feed Water Hardness, Regeneration Factor, the controller will calculate the System Capacity.

Maximum Interval Regeneration Days System will automatically regenerate even if the water capacity was not reached in the time

allotted. (Set on site)

Hankscraft Runxin RevV20 Valve Manual

Page 7: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

5

1.3. Service Condition

Hankscraft valve(s) should be used within the below conditions: Items Requirement

Working conditions

Water pressure 0.2MPa~0.6MPa (29-87psi)

Water temperature 5℃~50℃ (41-122 F)

Working environment

Environment temperature 5℃~50℃ (41-122 F)

Relative humidity ≤95% (25℃) (77 F)

Electrical facility AC100~240V/50~60Hz

Inlet water quality

Water turbidity < 5FTU

Water hardness First Grade Na+ < 6.5mmol/L; Second Grade Na+ < 10mmol/L

Free chlorine < 0.1mg/L or ppm

Iron2+ < 0.3mg/L or ppm

CODMn < 2mg/L (O2) In the above table, First Grade Na+ represents First Grade Na+ Exchanger. Second Grade Na+

represents Second Grade Na+ Exchanger.

When the water turbidity exceeds the conditions, a filter should be installed on the inlet of control valve.

When the water hardness exceeds the conditions, the outlet water hardness will hardly reach the requirement of boiler feed water (0.03 mmol/L or 0.18 gpg). It is suggested to adopt a second grade softener.

Hankscraft Runxin RevV20 Valve Manual

Page 8: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

6

1.4. Product Structure and Technical Parameters

A. Product Dimension (The below images are used for reference and are subject to the real product).

Stmcture RevV 20-A2

906.5

(view without side eonnccloJ)

~...f=:!~-~-, Ba..., \ Flow Met« L <f' _gUN Rire.-Pipe

1-t n. ' D-GB OOmm)

( v1cw without stdc ~<~nee tor)

Structure ofRevV 20-B2

248.5

Riser Pipe ·I/2'D-GB

(SOmm)

BOITOM 02

_ TOP 02

Hankscraft Runxin RevV20 Valve Manual

Page 9: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

7

B. Technical Parameter Transformer Output: DC24V/1.5A

Remark: M—Male F—Female OD—Outer Diameters

1.5. Installation

A. Installation notice Before installation, read all instructions completely. Then obtain all materials and tools

needed for installation. The installation of the softening system, pipes, and circuits should be completed by a

certified water professional to ensure the product will function and operate correctly. Perform installation according to the regional pipeline regulations and the specification of

Water Inlet, Water Outlet, Drain Outlet, and Brine Line Connector.

Model Connector Size Flow Rate

m3/h @0.3MPa

Remark Inlet/ Outlet

Drain Outlet

Brine Line Connector Base Riser

Pipe

RevV 20-A 2″M 1″M 3/4″M 4”-8UN

1.5″OD (50mm)

10 (44GPM)

Time clock or meter type; Top-mounted

RevV 20-B 2″M 1″M 3/4″M 4”-8UN

1.5″OD (50mm)

10 (44GPM)

Time clock or meter type; Side-mounted

Hankscraft Runxin RevV20 Valve Manual

Page 10: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

8

B. Device Location ① The filter or softener should be located close to the drain. ② Ensure that the unit is installed with enough space for operation and maintenance. ③ Brine tank needs to be close to the softener. ④ The unit should be kept away from heat, and should not be exposed to the elements. Sunshine or rain will cause the system damage. ⑤ Avoid introducing the system to Acid/Alkaline feed water or Magnetism/vibration, as this may cause the system to malfunction. ⑥ Do not install the filter, softener, or drain pipeline in areas where temperature may drop below 5℃, or rise above 50℃. (41F~122F) ⑦ Install the system in a location where the risk of loss for the customer is minimal, in case of water leaking. C. Pipeline installation (RevV 20-A top-mounted as an example: Figure 1-3)

① Install Control Valve a. As the Figure 1-1 shows, select a riser pipe that is 50mm OD, glue the riser pipe to the bottom strainer and put it into the mineral tank, cut the excessive tube off that is coming out the top opening of the pressure tank. Plug the riser tube to prevent unwanted minerals. b. Fill the mineral tank with resin, height according to the design code. c. Attach the top distributor basket to the valve. d. Insert and fasten the riser tube into the control valve. Note: ●The length of riser tube should not be higher than 2mm nor lower than 5mm from the tank’s top opening height, and its top end should be rounded to avoid damage of the O-ring inside the valve. ●Avoid dropping the O-ring from inside the control valve while rotating it on the tank.

② Install Flow Meter

As below figure shows, put the sealing ring into the nut of the flow meter, and attach it to the water outlet; insert sensor (probe wire) into the flow meter.

Hankscraft Runxin RevV20 Valve Manual

Page 11: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

9

③ Pipeline Connection a. As Figure1-3 shows, installation of a pressure gauge on water inlet. b. Install sampling valves to inlet, outlet, and pipeline A.B.C.D. c. Inlet pipeline should be parallel to outlet pipeline. Fasten the inlet and outlet pipeline(s) with a fixed holders.

Note: ● If making a soldered copper installation, do all sweat soldering before connecting pipes to the valve. Torch heat will damage plastic parts. ●When turning threaded pipe fittings onto plastic fitting, be sure not to cross thread. ●If the valve is a time clock type, skip step ②. ④ Install Drain Pipeline

Glue the drain outlet with UPVC (DN40). Put drain outlet pipe to sewer as shown in the Figure 1-4.

Note: ● Control valve should be higher than the drain outlet, and should be separated from the drain hose by at least 2 inches. ● Be sure not to connect the drain line directly to the sewer to avoid wastewater contamination.

⑤ Connect Brine Tube

a. As Figure1-5 shows, use 3/4” brine tube hose connector over the end of the brine tube. b. Insert the tube bushing into the end of the brine tube. c. Tighten the brine draw hose connector to the brine line connector. d. Connect the other end of the brine line hose to the brine tank.

Note: Keep brine line short and smooth. Line should not be bent or plugged.

Hankscraft Runxin RevV20 Valve Manual

Page 12: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

10

2. Basic Setting & Usage

2.1. The Functions of the PC Board

A. Time of day indicator

Light on,display the time of day. Light flashes,reminds you to reset the time of day if electrical service was interrupted

for 3 days or more (If electrical service was interrupted for less than 3 days, there is no need to reset the time). B. Button lock indicator Light on, indicates the buttons are locked. At this time, pressing any single button will not work (If the display is not used for 1 minute, will light and lock the buttons). Solution:to unlock press and hold both and for 5 seconds until the light turns off. C. Program mode indicator Light on,enter program display mode. Use or to view all values. When flashes, enter program set mode. Press or to adjust values. D. Menu/Confirm button Press , light turns on, enter program display mode and use or to view all values. In program display mode, press , will flash, enter program set mode, press or

Hankscraft Runxin RevV20 Valve Manual

Page 13: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

11

and adjust values. Press after all programs are set, a confirmation beep will sound meaning all settings are complete; returning to program display mode. E. Manual/Return button Press in any status, it will proceed to next cycle. (Example: Press In Service status, it will start regeneration cycles instantly; Press while it is in Backwash status, it will end backwash and go to Brine & Slow Rinse). Press in program display mode, and it will return to in Service; Press in program set mode, and it will return program display mode. Press while adjusting the value, it will return to the program display mode directly without saving value(s). F. Down ▼ and Up ▲ In program display mode, press ▲or ▼ to view all values. In program set mode, press ▲ or ▼ to adjust values.

2.2. Basic Setting & Usage A. Parameter Specification

Function Indicator Factory Default

Parameter set range Instruction

Time of Day 00:00~ 23:59 Set the time of day when “:” is flashing.

Control Mode A-01 A-01

A-01 Regeneration happens when the capacity reaches zero and the preset time of regeneration is reached.

A-02 Regeneration happens when the capacity reaches zero.

A-03

Meter Delayed Regeneration type, but by setting Resin Volume, Feed Water Hardness, Regeneration Factor, the controller will calculate the System Capacity. Regeneration mode same as A-01.

A-04

Meter Immediately Regeneration Type, but by setting Resin Volume, Feed Water Hardness, Regeneration Factor, the controller will calculate the System Capacity. Regeneration mode same as A-02.

Service Days 1-03D. 0~99 Days Only for Time Clock Type, regeneration by days.

Service Hours 1-20H. 0~99 Hours Only for Time Clock Type, regeneration by hours.

Regeneration Time 02:00 02:00 00:00~

23:59 Regeneration time; when “:” light is on.

Hankscraft Runxin RevV20 Valve Manual

Page 14: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

12

Resin Volume 20L. 20L. 5-500L. Resin volume in brine tank (L).

Feed Water Hardness Yd1.2 1.2 0.1-9.9 Feed water hardness (mmol/L).

Exchange Factor AL.65 0.65 0.30-0.99 Related to the raw water hardness. When hardness

is higher, the factor is smaller. Water Treatment Capacity

10 m3 0~999.99 m3

Water treatment capacity per cycle (m3).

Backwash Time 10 min. 0~99 Backwash time (Minute).

Brine & Slow Rinse Time 60 min. 0~99 Brine & Slow rinse time (Minute).

Brine Refill Time 5 min. 0~99 Brine refill time (Minute).

Fast Rinse Time 10 min. 0~99 Fast rinse time (Minute).

Maximum Interval Regeneration Days

H-30 30 0~40 Regenerate on this day even though the available volume of treated water did not reach to zero (0).

Output Control Mode b-01 b-01 b-01 or b-02

Mode b-01: Signal is sent at the start of regeneration and shuts off at the end of regeneration. (Connection refer to the Figure on P3) Mode b-02: Signal is available only during intervals of the regeneration cycles and in service (Connection refer to the Figure on P3).

Hankscraft Runxin RevV20 Valve Manual

Page 15: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

13

B. Process Display

Illustration

In Service status, shown in figure A/B/C/D; In Backwash status, shown in figure E/C; In Brine & Slow Rinse status, shown in F/C; In Brine Refill status, shown in figure G/C; In Fast Rinse status, shown in figure H/C. In each status, every figure is shown for 15 seconds.

Above displays are using the Meter Type as an example. For the Time Clock Type, it shows the rest days or hours, such as 1-03D or 1-10H.

The display screen will only show “-00-” when the electrical motor is running. The time of day figure “” flashes continuously, such as “12:12” flashing, indicates a long

outage of power. This is a reminder to reset the time of day. The display will show the error code, “-E1-” when the system is in error.

C. Working Process: Service→ Backwash→ Brine & Slow Rinse→ Brine Refill→ Fast Rinse→ Service. D. Usage

After installation is completed, parameters are set, and a trial run is completed, the valve is ready to be put into use. In order to ensure the quality of outlet water, the user should complete the steps below:

① Ensure that there is solid salt at all times in the brine tank when the valve is used for softening. The brine tank should use softening salts only, 99.5% pure.

② Test the product water and raw water hardness on a regular basis. When the outlet water hardness is at an undesired level, press the button; the valve will temporary regenerate (It will not affect the original set operation cycle.)

③ When the feed water hardness changes, you can adjust the water treatment capacity as follows:

Press and hold both and for 5 seconds to lift the lock status. Press , and the light turns on, then press , the display shows the control mode. If it shows A-01 or A-02, press

two times, and the display will show the given water treatment capacity (If the control mode shows A-03 or A-04, then press three times, the display will show the feed water hardness); Press again, on display will flash. Press or to change the capacity value (Or water hardness). Press a confirmation beep will sound finishing the adjustment. Press to exit and return to service status.

To calculate the water treatment capacity, refer to the manufacturer’s specifications. Selecting A-03 or A-04 intelligent control mode, the control will automatically calculate the water treatment capacity by setting resin volume, feed water hardness, and regeneration factors.

Hankscraft Runxin RevV20 Valve Manual

Page 16: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

14

④ For A-01 or A-03 control mode (Delayed regeneration type), ensure the time is set correctly. If the time is not correct, you can adjust as follow: After lifting the lock status, press , the buttons and light will turn on. Then press , the buttons and hour value will flash. Press or to change the hour value; Press again, and minute value will flash. Press or to change the minute value; Press a confirmation beep will sound finishing the adjustment. Press to exit and return to service status.

The regeneration parameters have been set when the control valve left the factory to default settings or set up on initial installation. Generally, there is no need for it to be reset.

3. Applications

3.1. Softener Flow Chart

Hankscraft Runxin RevV20 Valve Manual

Page 17: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

15

3.2. The Function and Connection of PC Board

Open the front cover of the control valve, you will see the main control board and connection port as seen below:

Functions on PC board:

Function Application Explanation

Signal output connector b-01

Outlet solenoid valve

If the system requires no hard water to flow from outlet or if controlling the liquid level in water tank.

Inlet pump Increase pressure for regeneration or washing. Use the liquid level controller to control inlet pump, ensuring there is water in tank.

Signal output connector b-02

Inlet solenoid valve or inlet pump

Used when inlet pressure is high, closes water inlet when valve is rotating to protect motor.

Pressure relief connector

Control the inlet bypass to release pressure

When valve is rotating, pressure relief connector opens to prevent pressure from increasing rapidly.

Interlock connector

To ensure only one control valve is in regeneration at a time in a system.

Used in RO Pre-treatment, water is supplied simultaneously but regenerate in turn. Also, used in second grade ion exchange equipment, etc.

Remote handling connector

Signal triggers the control to rotate to the next cycle.

It is used for on-line inspection systems, PC connections, and automatic or remote controlling valve.

Hankscraft Runxin RevV20 Valve Manual

Page 18: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

16

A. Signal Output Connector 1) Control Solenoid Valve (Set b-01) ① Solenoid valve on the outlet controls the water level in brine tank. Instruction: If the system requires there to be no hard water flow from the outlet in regeneration cycle (Mainly for no hard water flow out when valve is switching or valve is in backwash or brine drawing positions), a solenoid valve could be installed on outlet, for wiring refer to Figure 3-1.

Function: When valve is in service status, if soft water tank is short of water, solenoid valve is open to

supply soft water, but if water tank has enough water, solenoid valve is closed, and no soft water is supplied. When the valve is in backwash status, there is no signal output. Therefore, the solenoid valve

is closed, and no water flows into soft water tank. ② Solenoid valve on inlet (Set b-02) Instruction: When inlet pressure exceeds (0.6MPa~87psi), install a solenoid valve on inlet. Control mode is b-02. Pressure is relieved when valve is switching to prevent damage, for wiring refer to Figure 3-2. As Figure 3-3 shows, it can also use the pressure relief port to work.

Instruction:

When inlet pressure is high, install a solenoid valve on inlet to ensure the valve can switch properly. When valve is in position for Service, Backwash, Brine & Slow Rinse, Brine Refill and Fast Rinse, solenoid valve is open. When valve is switching between cycles, the solenoid valve

Hankscraft Runxin RevV20 Valve Manual

Page 19: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

17

is closed, ensuring no water can flow to the valve protecting it from damage during transition. This can prevent water bleed through or water hammering.

Use interlock cables to daisy chain valves in parallel, or series, in the same system which is suited for RO pretreatment system or second grade Na+ system. For wiring refer to Figure 3-4:

2) Liquid Level Controller Controls Inlet Pump (Two-phase motor) ( Set b-01) Instruction: For a system using well or middle-tank supplying water, liquid level controller and valve, together, control pump opening or closing. For wiring refer to Figure 3-5:

Function: When the valve is in service, if the water tank is short of water, it starts the pump, but if the

tank has enough water, the switch of liquid level controller is closed, so the pump will not be in operation. When valve is in regeneration, inlet always has water no matter the condition(s) in the water

tank. Valve does not pass water through the outlet in regeneration cycle, ensuring no water drains into the brine tank.

3) Liquid Level Switch in Water Tank Controls Inlet pump (Three-phase) (Set b-01)

Hankscraft Runxin RevV20 Valve Manual

Page 20: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

18

4) Control Inlet Booster Pump (Set b-01 or b-02) Instruction:

If inlet water pressure is less than (0.2MPa~29psi), which makes drawing difficult, a booster pump is suggested to be installed on the inlet. Control mode b-01. When the system is in regeneration, booster pump is open, for wiring refer to Figure 3-7. If the booster pump current is higher than 5A, system needs to have a contactor installed. For wiring refer to Figure 3-8 below.

B. Interlock Instruction:

In a parallel water treatment system, to ensure only one valve in regeneration or washing cycle and (n-1) valves in service, that is, that the function of supplying water simultaneously and regenerating individually, for wiring refer to Figure 3-9.

Note: Use Interlock Cable to connect CN8 to CN7 on next valve in the loop.

In a system with several valves, if the interlock cable is disconnected, the system will be divided into two individual systems.

Hankscraft Runxin RevV20 Valve Manual

Page 21: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

19

C. Pressure Relief Output

Valve will cut off feed water to the drain line when there is a switch in regeneration cycles. In some water treatment system, e.g. Deep Well, one booster pump was installed on the inlet to increase the system water feed pressure. This cut-off will prevent pressure on the inlet from rising too fast, protecting the valve. Pressure Relief Output can be used to avoid this problem. For wiring refer to Figure 3-10.

D. Remote Handling Connector

Online TDS meter can monitor treated water rather than a flow meter, or PLC controlling

the regeneration time. When the controller receives a contact closure from above instruments, regeneration begins. For wiring refers to Figure 3-11:

E. Interlock System

For 2 or more valves that are interlocked, connected in one system, and when all valves are in service but regenerate individually. For wiring refer to Figure 3-12.

Hankscraft Runxin RevV20 Valve Manual

Page 22: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

20

F. Series System

This is a 2 or more valve system, all in service, with one flow meter for the entire system. For

the time type valve, the regeneration time should be set and adjusted to the Max; for the volume type valve, connect its signal output connector with the remote handle connector of the time-type valve. This provides the function of supplying water simultaneously and regenerating in order. For wiring refer to Figure 3-13:

3.3. System Configuration and Flow Rate Curve

A. Product Configuration Softener valve for floating bed configuration with tank, resin volume, brine tank and injector model.

Tank Size (in & mm)

Resin Volume (ft3 & L)

Flow Rate (m3/h)

Brine Tank Size

(in & mm)

The Minimum Salt Consumption for

Regeneration (lbs. & kg)

Injector Model

19.69”/500× 70.87”/1800 7.06/200 5.0 29.13”/740×

50.20”/1275 66.14/30.00 7401

23.63”/600× 70.87”/1800 10.60/300 7.0 29.13”/740×

50.20”/1275 99.21/45.00 7403

29.53”/750× 70.87”/1800 15.90/450 11.0 33.87”/840×

52.56”/1335 148.81/67.50 7404

Attention: The flow rate calculation is based on linear velocity 25m / hr.; the minimum salt consumption for regeneration calculation is based on salt consumption 150g / L (Resin).

B. Flow Rate Characteristic 1) Pressure-flow Rate Curve

Hankscraft Runxin RevV20 Valve Manual

Page 23: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

21

2) Injector Parameter Table Inlet Pressure Draw Rate (Gal/m & L/m)

psi & MPa 7401 Coffee

7402 Pink

7403 Yellow

7404 Blue

21.76/0.15 2.80/10.61 3.66/13.86 4.25/16.08 6.61/25.02

29.01/0.20 3.43/13.00 4.39/16.60 5.10/19.32 7.76/29.37

36.26/0.25 3.82/14.47 4.80/18.17 5.63/21.30 8.69/32.91

43.51/0.30 4.23/16.00 5.28/20.00 6.18/23.40 9.56/36.20

50.76/0.35 4.56/17.28 5.72/21.64 6.65/25.19 10.23/38.73

58.02/0.40 4.90/18.55 6.16/23.33 7.13/26.98 10.94/41.43 3) Configuration for Standard Injector and Drain Line Flow Control

Tank Dia. In & mm

Injector Model

Injector Color

Draw Rate

Slow Rinse

Brine Refill DLFC&

Holes Quantity

Backwash / Fast Rinse

Gal/m & L/m

Gal/m & L/m

Gal/m & L/m

Gal/m & L/m

19.69”/500 7401 Coffee 4.23/16.0 2.79/10.56 6.08/23 #1 12.23/46.3

21.65”/550 7402 Pink 5.28/20.0 3.67/13.88 7.45/28.2 #2 17.70/67

23.62”/600 7403 Yellow 6.18/23.4 4.16/15.75 8.69/32.9 #3 18.76/71

29.53”/750 7404 Blue 9.56/36.2 6.39/24.17 13.34/50.5 #4 19.81/75 Attention: The above data for the product configuration and relevant characteristics are only for reference. When put into practice, results are subject to the different requirements of raw water hardness and application.

3.4. Parameter Settlement ① Service Time T1 Water treatment capacity:

Q=VR×K÷YD (m3) Hardness of inlet water (mmol/L)

Exchange factor (mmol/L) 400~1000. Down-flow regeneration, take 400~750. Up-flow regeneration, take 450~1000. If the inlet water hardness is higher, the factor is smaller.

Resin volume (m3)

Hankscraft Runxin RevV20 Valve Manual

Page 24: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

22

By hours: T1=Q÷Qh (Hour)

Water treatment capacity per hour (m3/h) Water treatment capacity (m3)

By days: T1=Q÷Qd (Day) Water treatment capacity per day (m3/d)

Water treatment capacity (m3)

② Backwash Time T2 It is subject to the turbidity of inlet water. Generally, It is suggested to be set to 10~15

minutes. The higher the turbidity is, the longer backwash time can be set. However, if the turbidity is more than 5 FTU, it would be better to install a filter before the exchanger.

③ Brine & Slow Rinse Time T3

T3= (40~50) × HR (min.) Generally, T3=45HR (min.)

In this formula, HR——the height of resin in exchange tank (m.) ④ Brine Refill Time T4

Down-flow regeneration:T4=0.45×VR÷Brine refill speed (min.) Up-flow regeneration:T4=0.34×VR÷Brine refill speed (min.)

In this formula, VR—— Resin volume (m3) The Brine refill speed is related to inlet water pressure. It is suggested to increase by 1~2

minutes of calculated brine refilling time to make sure there is enough water in tank. (The condition is that there is a level controller installed in the brine tank).

⑤ Fast Rinse Time T5

T5=12×HR (min.) Generally, the water for fast rinse is 3~6 times of resin volume. It is suggested to be set

10~16 minutes, but subject to the outlet water reaching the requirement.

⑥ Exchange Factor Exchange factor =E / (k×1000) In this formula, E——Resin working exchange capability (mmol/m3), it is related to the

quality of resin. Down-flow regeneration, take 800~900. Up-flow regeneration, take 900~1200. K——Security factor, always take 1.2~2. It is related to the hardness of inlet water: the higher the hardness is, the bigger the K is. ⑦ Regeneration Time The whole cycle for regeneration is about two hours. Please try to set up the regeneration time

when you don’t need water according to the actual situation. The calculation of parameters for each step is only for reference, the actual time will be

determined/adjusted by the water softener supplier. This calculation procedure of softener is only for industrial application; it is not suitable for small softeners in residential applications.

Hankscraft Runxin RevV20 Valve Manual

Page 25: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

23

3.5. Parameter Enquiry and Setting

3.5.1. Parameter Enquiry When light is on, press and hold both and for 5 seconds to lift the button lock

status; then press and lights up, enter to program display mode; press or to view each value according to below process. (Press to exit and return to service status).

3.5.2. Parameter Setting

In program display mode, press and enter into program set mode. Press or to adjust the value.

Hankscraft Runxin RevV20 Valve Manual

Page 26: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

24

3.5.3. The Steps of Parameter Setting

Items Process steps Symbol

Time of Day

When time of day “08:30” continuously flashes; it is a reminder to reset; 1. Press to enter into program display mode; both and symbol light on, “:” flashes; Press , both and hour value flash, use or to adjust the hour value; 2. Press again, both and hour value flash, use or to adjust the minute value; 3. Press a confirmation beep will sound, then finish adjustment, press to return.

Control Mode

1. In control mode display status, press and enter into program set mode, and 01 values flash; 2. Press or , set the value to be A-01, A-02, A-03 or A-04 control mode 3. Press a confirmation beep will sound, then finish adjustment, press to return.

Regeneration Time

1. In regeneration time display status, press and enter into program set mode. and 02 flashes; Press or to adjust the hour value; 2. Press again, and 00 flashes, press or to adjust the minute value; 3. Press a confirmation beep will sound, then finish adjustment, press to return.

Water Treatment Capacity

1. In water treatment capacity display status, it shows and 80.00. Press and enter into program set mode. Press and 80.00 will flash; 2. Press or to adjust the water treatment capacity value (m3); 3. Press a confirmation beep will sound, then finish adjustment, press to return.

Resin Volume

1. In resin volume display status, it shows 100 L. Press and enter into program set mode. and 50 value will flash; 2. Press or to adjust the volume value(L); 3. Press a confirmation beep will sound, then finish adjustment, press to return.

Feed Water Hardness

1. In feed water hardness display status, it shows yd1.2. Press and enter into program set mode. and 1.2 value flash; 2. Press or to adjust the volume value(mmol/L); 3. Press a confirmation beep will sound, then finish adjustment, press to return.

Hankscraft Runxin RevV20 Valve Manual

Page 27: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

25

Exchange Factor

1. In exchange factor display status, it shows AL.55. Press and enter into program set mode. and 55 flash; 2. Press or to adjust the exchange factor value; 3. Press a confirmation beep will sound, then finish adjustment, press to return.

Backwash Time

1. In backwash time display status, it shows and 2-10. Press and enter into program set mode. and 10 flash; 2. Press or to adjust the backwash time; 3. Press a confirmation beep will sound, then finish adjustment, press to return.

Brine& Slow Rinse Time

1. In Brine& slow rinse time display status, it shows and 3-60:00. Press and enter into program set mode. Press and 60 will flash;Press and , modify the Brine & slow rinse minute time; modify the Brine & slow rinse second time; 3. Press a confirmation beep will sound, then finish adjustment, press to return.

Fast Rinse Time

1. In Fast rinse time display status, it shows and 5-10:00. Press and enter into program set mode. Press and 10 will flash;

Press and , to modify the Fast rinse minute time; 2. Press a confirmation beep will sound, then finish adjustment, press to return.

Brine Refill Time

1. In Brine refill time display status, it shows and 4-05:00. Press and enter into program set mode. Press and 05 flashes;

Press and , to modify the Brine refill minute time; modify the Brine refill second time; 2. Press a confirmation beep will sound, then finish adjustment, press to return.

Maximum Interval Regeneration Days

1. In maximum Interval regeneration days display status, it shows H-30. Press and enter into program set mode. Press and 30 flashes; 2. Press or to adjust the Interval regeneration days; 3. Press a confirmation beep will sound, then finish adjustment, press to return.

Signal Output Mode

1. In signal output mode display status, it shows b-01. Press and enter into program set mode. and 01 will flash; 2. Press or to adjust the b-02; 3. Press a confirmation beep will sound, then finish adjustment, press to return.

For example, the fast rinse time of a softener is 12 minutes. After regenerating, the chlorides in the outlet water are always higher than normal, indicating that there is not enough time for fast rinse. If you want to increase the fast rinse time, the modification steps as follows: ① Press and hold both and to lift the button lock status ( light off);

Hankscraft Runxin RevV20 Valve Manual

Page 28: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

26

② Press , and lights up;

③ Press or continuously until lights up. Then the digital area shows: 4-12M; ④ Press , then and 12 will flash;

⑤ Press continuously until 12 changes to 15; ⑥ Press , there will be a confirmation beep and the figure will stop flashing; the program will return to the adjustment status.

⑦ If you want to adjust other parameters, you can repeat the steps from ② to ⑤; if you don’t, press and quit from the inquiry status, the display will show the current service status.

3.6. Trial Running

After installing the control valve on the resin tank with the connected pipes, and setting up the relevant parameters for the system, please conduct a trail run as follows:

A. Close the inlet valve B & C, and open the bypass valve A. After cleaning the foreign materials in the pipe, close the bypass valve A. (as Figure 1-4 shows) B. Fill the brine tank with the planned amount of water and adjust the air check valve. Then add solid salt to the tank dissolving the salt as much as possible.

C. Turn on power. Press and go in the Backwash position; when light is on (For floating bed, switch valve to Fast Rinse), slowly open the inlet valve B to 1/4 position, making the water flow into the resin tank; you should hear the sound of air-out from the drain pipeline. After all of the air is out of the pipeline, open inlet valve B completely to clean the foreign material out of the resin tank until the outlet water is clean. It will take 8~10 minutes to finish the whole process depending on media. D. Press , advancing the position from Backwash to Brine & Slow Rinse; when light is on it indicates the valve is entering Brine & Slow Rinse. The air check valve closes when control valve finishes drawing brine; slow rinse starts. About 60~65 minute process.

E. Press to get to Fast rinse position. Light turns on. It takes about 10~15 minutes. Remove some outlet water for testing: if the water hardness reaches the desired requirement, and the chlorides in the water are almost the same level compared with the inlet water, then proceed to the next step. F. Press to Brine refill position. When the light is on it indicates the brine tank is

Hankscraft Runxin RevV20 Valve Manual

Page 29: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

27

being refilled with water to the required level. It takes about 5~6 minutes, then add solid salt to the brine tank.

G. Press , this forces the control valve to advance to “In Service” status; light turns on and valve will start running. Note: When the control valve enters into the regeneration status, all programs will be finished automatically according to the setting time; if you want one of the steps to terminate early, press

. If the water inflow is too fast, the media in tank will be damaged. When water inflow is too slow, there is a sound of air emptying from the drain pipeline. After changing resin, empty air that is in the resin according to the above Step C.

In the process of trial running, ensure there are no leakages in any cycle. The time for Backwash, Brine & Slow Rinse, Brine Refill and Fast Rinse position can be set and carried out according to the calculation in the formula or suggestions from the control valve suppliers.

Hankscraft Runxin RevV20 Valve Manual

Page 30: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

28

3.7. Trouble-Shooting A. Control Valve Fault

Problem Cause Correction

1. Softener fails to regenerate.

A. Electrical service to unit has been interrupted. B. Regeneration cycles set incorrectly. C. Controller is defective. D. Motor fails to work.

A. Verify permanent electricity (Check fuse, plug, pull chain or switch). B. Reset regeneration cycles. C. Replace controller. D. Replace motor.

2. Regeneration time is not correct.

A. Time of Day is not set correctly. B. Power failure for more than 3 days.

Check program and reset time of day.

3. Softener yielding hard water.

A. Bypass valve is open or leaking. B. No salt in brine tank. C. Injector plugged. D. Insufficient water flowing into brine tank. E. Leak at O-ring on riser pipe. F. Internal valve leak. G. Regeneration cycles not correct. H. Shortage of resin. I. Bad quality of feed water or turbine blocked.

A. Close or repair bypass valve. B. Add salt to brine tank and maintain salt level above water level. C. Change or clean injector. D. Check brine tank refill time. E. Make sure riser pipe is not cracked. Check O-ring and tube pilot. F. Change valve body. G. Set correct regeneration cycles in the program. H. Add resin to mineral tank and check whether resin leaks. I. Reduce the inlet turbidity, clean or replace turbine.

4. Softener fails to draw brine.

A. Line pressure is too low. B. Brine line is plugged. C. Brine line is leaking. D. Injector is plugged. E. Internal control leak. F. Drain line is plugged. G. Sizes of injector and DLFC don’t match system size. H. Ball valve or cable failure

A. Increase line pressure. B. Clean brine line. C. Replace brine line. D. Clean or replace injector. E. Replace valve body. F. Clean drain line flow control. G. Select correct injector size and DLFC according to the P32 requirements. H. Replace ball valve or cable

5. Unit uses too much salt.

A. Improper salt setting. B. Excessive water in brine tank.

A. Check salt usage and salt setting. B. See problem no.6.

6. Excessive water in brine tank.

A. Brine refill time set too long. B. Foreign material in brine line. C. Foreign material in brine valve / plugs drain line flow control. D. No overflow safety in brine tank / float assembly. E. Ball valve doesn’t close.

A. Reset correct brine refill time. B. Clean brine line. C. Clean brine valve and brine line. D. Stop water supply and reinstall float assembly in brine tank. E. Close or replace ball valve or cable.

7. Pressure lost or iron in outlet water.

A. Iron in the inlet pipe. B. Iron mass in the softener. C. Fouled resin bed.

A. Clean the inlet pipe. B. Clean valve and add resin cleaning chemical, increase frequency of

Hankscraft Runxin RevV20 Valve Manual

Page 31: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

29

D. Too much iron in the raw water. regeneration. C. Check backwash, brine draw and brine tank refill. Increase frequency of regeneration and backwash time. D. Iron removal equipment is required to install before softening system.

8. Loss of mineral through drain line.

A. Air in water system. B. Bottom distributor basket damaged. C. Improperly sized drain line flow control.

A. Check that well system has proper air elimination. B. Replace bottom distributor basket. C. Check for proper drain rate.

9. Control cycles continuously.

A. Locating signal writing breakdown. B. Controller is faulty. C. Foreign material stuck the driving gear. D. Time of regeneration steps were set to zero.

A. Check and connect locating signal wiring. B. Replace controller. C. Remove foreign material. D. Check program setting and reset.

10. Drain flows continuously.

A. Internal valve leak. B. If there was a power outage during the backwash cycle.

A. Check and repair valve body or replace it. B. Adjust valve to service position or turn off bypass valve and restart.

11. Interrupted or irregular brine.

A. Water pressure too low or not stable. B. Injector is plugged or faulty. C. Air in resin tank. D. Material in resin tank during backwash.

A. Increase water pressure. B. Clean or replace injector. C. Check and find the reason. D. Remove the material in resin tank.

12. Water flows from drain or brine line after regeneration.

A. Foreign material in the valve; valve cannot close completely. B. Hard water mixed in valve body. C. Water pressure is too high which results in the valve not being in the right position. D. Ball valve or cable failure.

A. Clean foreign material in valve body. B. Change valve core or sealing ring. C. Reduce water pressure or use pressure release device. D. Replace ball valve or cable.

13. Salt water in softened water.

A. Foreign material in injector or injector fails to work. B. Brine valve cannot be shut-off. C. Time of rapid rinse too short.

A. Clean and repair injector. B. Repair brine valve or clean it. C. Extend rapid rinse time.

14. Unit capacity decreases.

A. Unit fails to regenerate or does not regenerate properly. B. Fouled resin bed. C. Salt setting incorrect. D. Softener setting incorrect. E. Reduced quality of raw water. F. Turbine of flow meter is stuck.

A. Regenerate according to the correct operation requirement. B. Increase backwash flow rate and time, clean or change resin. C. Readjust brine drawing time. D. Test outlet water, recount, and reset parameters. E. Manual regenerate the system temporarily, then reset regeneration cycle. F. Disassemble flow meter and clean it or replace turbine.

Hankscraft Runxin RevV20 Valve Manual

Page 32: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

30

B. Controller Fault

Problem Cause Correction

1. All indicators displayed on front panel.

A. Wiring of front panel failure. B. Control board is faulty. C. Transformer damaged. D. Electrical service not stable.

A. Check and replace the wiring. B. Replace control board. C. Check and replace transformer. D. Check and adjust electrical service.

2. No display on front panel.

A. Wiring of front panel failure. B. Front panel damaged. C. Control board damaged. D. Electricity is interrupted.

A. Check and replace wiring. B. Replace front panel. C. Replace control board. D. Check electricity.

3. E1 Flash

A. Wiring of locating board failure. B. Locating board damaged. C. Mechanical driven failure. D. Faulty control board. E. Wiring of motor failure. F. Motor 1 damaged.

A. Replace wiring. B. Replace locating board. C. Check and repair mechanical part. D. Replace control board. E. Replace wiring. F. Replace motor 1.

4. E2 Flash

A. Wiring of locating board failure. B. Locating board damaged. C. Mechanical driven failure. D. Faulty control board. E. Wiring of motor failure. F. Motor 2 damaged.

A. Replace wiring. B. Replace locating board. C. Check and repair mechanical part. D. Replace control board. E. Replace wiring. F. Replace motor 2.

6. E3 or E4 Flashes A. Control board is faulty. A. Replace control board.

Hankscraft Runxin RevV20 Valve Manual

Page 33: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

31

3.8. Assembly & Parts

REVV 20-A (63610) exploring drawing

Hankscraft Runxin RevV20 Valve Manual

Page 34: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

32

RevV 20-A: Valve Body Components (set up as filter: remove item no. 46 and no.47)

Item No. Description Part No. Quantity

Item No. Description Part No. Quantity

1 O-ring 48.9x2.62 8378071 1 25 Dust Cover 8005010 1 2 O-ring 104.6X5.7 8378146 1 26 Control Board 6382027 1

3 Connector 8458018 1

27 Wire for Locating Board 5511002 1

4 Screw, Cross ST3.9X16 8909003 8 28 Wire for Display

Board 5512001 1

5 Drain Line Flow Control 8468010 1 29 Display Board 6381003 1

6 Injector 5468014 1 30 Front Cover 8300017 1 7 O-Ring 8371004 1 31 Label 8865016 1 8 Cover, Injector 8315006 1 32 Cable Clip 8126004 2 9 Hexagonal Nut 8940016 1 33 Wire for power 5513001 1 10 Tube 8457025 1 34 Pin 8994009 1

11 Screw, Cross ST2.9X9.5 8909008 3 35 Small Gear 8241008 1

12 Seal Ring 8370016 1 36 Bolt C4X12 8971001 1 13 Fix Disk 8469010 1 37 Motor 6158036 1 14 Moving Disk 8459011 1 38 Hexagonal Nut 8940002 3 15 Moving Seal Ring 8370018 1 39 Line clip 8126002 1

16 Shaft 8258005 1 40 Screw, Cross M4X20 8902007 1

17 Anti-friction Washer 8216006 1 41 Connecting Board 8152007 1

18 O-ring 59.92x3.53 8378110 2 42 Screw, Cross

ST3.9X16 8909016 4

19 O-ring 117.6X3.55 8378133 1 43 Screw, Cross

M4×12 8902005 1

20 Fitting Nut 8092005 1 44 Screw, Cross M4X36.5 8902012 4

21 Locating Board 6380015 1

45

Valve Body(ABS+GF10) 8022052

1 22 Screw, Cross

ST2.2X6.5 8909004 6 Valve Body

(PPO+GF10) 8022053

23 Gear 5241004 1 46 Flow Meter 5447003 1

24 Screw, Cross ST4.8X19 8909018 1 47 Probe Wire 6386001 1

Hankscraft Runxin RevV20 Valve Manual

Page 35: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

33

5447003 Flow meter:

5447003 Flow Meter Components:

5458002 Side-mounted Connector:

5458002 Side-mounted Connector Components:

Item No. Description Part No. Quantity Item

No. Description Part No. Quantity

1 Animated Connector 8947004 1 5 O-ring 60X4 8378137 1 2 Seal Ring 8371008 1 6 Turbine 5436005 1 3 Connector 8458016 1 7 Rotator 8211003 1 4 Fixed Connector 8109006 1 8 Flow Meter Shell 8002702 1

Item No. Description Part No. Quantity Item

No. Description Part No. Quantity

1 Connector 8458037 1 3 Joint 8457017 1 2 O-ring 110X4.5 8378140 1 4 Steel Yoke End 8271003 1

Hankscraft Runxin RevV20 Valve Manual

Page 36: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

34

RevV 20-B (63610B) Exploring Drawing

Hankscraft Runxin RevV20 Valve Manual

Page 37: Multi-functional Flow Control Valve for Water Treatment ... · Multi-functional Flow Control Valve for. Water Treatment Systems Hankscraft Runxin RevV20. Instruction Manual. Please

35

RevV 20-B: Valve Body Components (set up as filter: remove item no. 38 and no.52)

Item No. Description Part No. Quantity Item

No. Description Part No. Quantity

1 Side Connector 5458002 1 28 Wire for Locating Board 5511002 1

2 Screw, Cross ST3.9X16 8909003 8 29 Dust Cover 8005023 1

3 Connector 8458018 1 30 Three Core Spring Line 5517001 1

4 O-ring 104.6X5.7 8378146 1 31 Bushings 8126006 1 5 O-ring 48.9x2.62 8378071 1 32 Wire Clip 8126001 1

6 Drain Line Flow Control 8468010 1 33 Front Box 8300025 1

7 Cover, Injector 8315006 1 34 Label 8865023 1 8 O-ring 8371004 1 35 Display Board 6381003 1 9 Injector 5468013 1 36 Cover 8315016 1 10 Tube 8457025 1 37 Buckle 8126004 2 11 Hexagonal Nut 8940016 1 38 Probe Wire 6386002 1 12 Seal Ring 8370016 1 39 Wire for Power 5513001 1 13 Fix Disk 8469010 1 40 Pin 8994009 1 14 Moving Disk 8459011 1 41 Small Gear 8241008 1 15 Moving Seal Ring 8370018 1 42 BoltC4X12 8971001 1 16 Shaft 8258005 1 43 Motor 6158036 1 17 Anti-friction Washer 8216006 1 44 Hexagonal Nut 8940002 3 18 O-ring 59.92x3.53 8378110 2 45 Buckle 8126002 1 19 O-ring 117.6X3.55 8378133 1 46 Screw, Cross M4X20 8902007 1 20 Fitting Nut 8092005 1 47 Connecting Board 8152007 1

21 Locating Board 6380015 1 48 Screw, Cross ST3.9X16 8909016 4

22 Screw, Cross ST2.2X6.5 8909004 6 49 Screw, Cross M4×12 8902005 1

23 Gear 5241004 1 50 Screw, Cross M4X36.5 8902012 4

24 Screw, Cross ST4.8X19 8909018 1

51

Valve Body (ABS+GF10) 8022052

1 25 Fixed Base 8109004 1 Valve Body

(PPO+GF10) 8022053

26 Control Board 6382027 1 52 Flow Meter 5447003 1

27 Screw, Cross ST2.9X9.5 8909008 15

Hankscraft Runxin RevV20 Valve Manual