Top Banner
Multi-function Tester (TC-V2.12k) ① Please carefully read this opera ② Our company will reserve the rig ③ For product appearance,please re ④ Please keep properly the operati
11

Multi-function Tester (TC-V2.12k)...2.5 Test zener diode When the shutdown or test is completed, the voltage stabilizing diode is put into the test area of the voltage stabilizing

Mar 01, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Multi-function Tester (TC-V2.12k)...2.5 Test zener diode When the shutdown or test is completed, the voltage stabilizing diode is put into the test area of the voltage stabilizing

Multi-function Tester (TC-V2.12k)

① Please carefully read this operation manual throughly before use

② Our company will reserve the right of interpretation for this manual

③ For product appearance,please refer to the actual product

④ Please keep properly the operation manual after you read

Page 2: Multi-function Tester (TC-V2.12k)...2.5 Test zener diode When the shutdown or test is completed, the voltage stabilizing diode is put into the test area of the voltage stabilizing

1 .........................................................................Review1.1 ...................................................................Instructions1.2 .........................................................................Features2 ...................................................Operating instructions2.1 ...............................................Key operation definition2.2 ......................................................................Power on2.3 ................................................................Test transistor2.4 ....................................................Automatic calibration2.5 ..........................................................Test zener diode2.6 .........................................................Infrared decoding2.7 ...................................................................Power off2.8 .............Built-in lithium battery voltage measurement2.9 ................................Built-in lithium battery charging3 ..............................................Performance parameters4 ...........................................................................FRQ5 ..................................................................Packing list

1 Review

1.1 Instructions

1.2 Function Introduction

TC-V2.12k is a multi-function tester using TFT graphic display.

Multi-function Tester(TC-V2.12k)

Content

Page 3: Multi-function Tester (TC-V2.12k)...2.5 Test zener diode When the shutdown or test is completed, the voltage stabilizing diode is put into the test area of the voltage stabilizing

2 Operating instructions

• Transistor tester

2.1 Key operation definition

2.2 Power on

There are two operations for multifunction keys

When the camera is turned off, press the multi-function button briefly, and the tester will turn on and measure automatically.

• Short press: Press the key not as short as 10 milliseconds and release the key in 1.5 seconds• Long press:Press the button for more than 1.5 seconds

• Power on & Measurement Interface

- Automatic measurement of NPN and PNP transistors、- N-channel and P-channel FETs, diodes (with dual diodes), resistors (with potentiometers), inductors, capacitors, thyristors,batteries (0.1-4.5V) and other components- Automatic test voltage stabilizing diode(0.01-30V)

- Automatic calibration function

• Infrared decoder

- Support Hitachi encoding- Infrared waveform display- Infrared receiving indication

Notice: Built-in lithium battery,It is forbidden to immerse the tester in water, and it is forbidden to approach the hot and high temperature source!

Notice: For your personal safety, please strictly observe the use of lithium battery standards and matters of attention!

• Others

- Measurement results using TFT graphic display- One-button operation- Automatic shutdown (shut down time can be set)- Built-in large capacity rechargeable lithium battery- Lithium battery voltage detection- Support Chinese and English bilingualism

Page 4: Multi-function Tester (TC-V2.12k)...2.5 Test zener diode When the shutdown or test is completed, the voltage stabilizing diode is put into the test area of the voltage stabilizing

2.3 Test transistor

When the shutdown or test is completed, the components to be tested are put into the test area of the test block, and press the locking handle, and press the multi-function button. The tester automatically performs the measurement. After the test is completed, the graphics show the measurement results.

• Placement of components The test seat is divided into the transistor test area and the voltage stabilizing diode test area, as detailed in the 1.1 machine instructions.• Non component, unidentified or component damage

• Battery (There are 6 forms:)

Notice: Be sure to discharge the component in front of the test seat so as not to damage the tester!

Notice: It is not recommended to use a tester to measure the battery! When measuring the battery, make sure that the voltage is less than 4.5V, or the tester will be damaged.

Page 5: Multi-function Tester (TC-V2.12k)...2.5 Test zener diode When the shutdown or test is completed, the voltage stabilizing diode is put into the test area of the voltage stabilizing

illustration: The following will no longer enumerate the various test methods of the components,explain only one of them.

• Triode

• Diode

• Double diode

Page 6: Multi-function Tester (TC-V2.12k)...2.5 Test zener diode When the shutdown or test is completed, the voltage stabilizing diode is put into the test area of the voltage stabilizing

The measurement result of the voltage regulator diode below 4.5V is also dual diode:

• Field effect tube

• Silicon-controlled

• Bidirectional triode thyristor

Page 7: Multi-function Tester (TC-V2.12k)...2.5 Test zener diode When the shutdown or test is completed, the voltage stabilizing diode is put into the test area of the voltage stabilizing

2.4 Automatic calibration

Potentiometer or two resistors:

Short connection of three test seats, short press multi function keys, the tester automatically calibrated.In the process of calibration, there is no need to do other operations except the short wiring is disconnected according to the prompt.

• Capacitor

• Inductor

• Start calibration

• Resistance One resistor:

Page 8: Multi-function Tester (TC-V2.12k)...2.5 Test zener diode When the shutdown or test is completed, the voltage stabilizing diode is put into the test area of the voltage stabilizing

2.5 Test zener diode

When the shutdown or test is completed, the voltage stabilizing diode is put into the test area of the voltage stabilizing diode, and the locking handle is pressed, and the multi-function button is pressed short. The tester starts and automatically measures, and the graphics show the measurement results after the test is completed.

• Break short connection

• Calibration end

Notice: Do not perform other operations during calibration so as not to affect calibration accuracy!

Notice: Do not put components in the component test area, or you can not test the voltage regulator diode!

Page 9: Multi-function Tester (TC-V2.12k)...2.5 Test zener diode When the shutdown or test is completed, the voltage stabilizing diode is put into the test area of the voltage stabilizing

2.6 Infrared decoding

2.7 Power off

After the component test is completed, the infrared remote controller is aligned to the "IR" test hole of the tester, press the remote control button, and the user code and data code are displayed after the tester is successfully decoded, and the corresponding infrared waveforms are displayed. If no decoding or decoding fails, the user code and data code can not be displayed. If the interface of the tester is not able to enter the infrared decoding interface, if the infrared decoding interface still displays the last successful decoding information. The upper right corner points are used to indicate whether the infrared data of the remote control is received. Red indicates that the infrared data is being received, and the blue indicates that the decoding is successful.

The multi-function tester has the function of timeout automatic shutdown and manual shutdown。

Press and hold the multi-function button in any state to forcibly shut down, including while measuring components.

When the component test is completed or the infrared decoding is completed and the automatic shutdown time is reached, the tester is automatically turned off. The auto-off time can be set by the hardware jumper, support 10 seconds, 15 seconds, 20 seconds and 25 seconds four-block timeout, the factory setting is 20 seconds.

• Automatic shutdown at timeout

• Manual shutdown

Notice: Adjust the automatic shutdown time to open the shell, and use the electric soldering iron to shorten the jump line.

Notice: Please do ESD static protection during welding!

illustration: The infrared decoder only supports Hitachi encoding format.

Page 10: Multi-function Tester (TC-V2.12k)...2.5 Test zener diode When the shutdown or test is completed, the voltage stabilizing diode is put into the test area of the voltage stabilizing

2.8 Built-in lithium battery voltage measurement

2.9 Built-in lithium battery charging

3 Performance parameters

Component type Rang Parameter description

The built-in lithium battery voltage will be detected before each component measurement and displayed. When the battery voltage is less than 3.0V, it will be forcibly shut down. Please charge at this time.

Multi-function tester can automatically identify components and pin arrangement, automatic range switching.

The main performance parameters are as follows:

Triode

DiodeForward pressure drop <4.50V

0.01-4.50V(Transistor test area)

0.01-30V(Voltage regulator test area)

Doublediode

Voltageregulator

diode

-

Amplification factor hfe,Base emitter voltage Ube,Collector DC current Ic,Collector-emitter reverse cut-off current Iceo、Ices,Protection diode forward voltage drop Uf①

forward voltage drop

Forward voltage drop, junction capacitance, reverse leakage current Ir ②

forward voltage drop, Reverse breakdown voltage

Reverse breakdown voltage

The charging port is a standard Micro USB port. Please use an external 5V power supply or USB power supply for charging.

Notice: Charge the input voltage up to 6V, do not use overvoltage, otherwise it will damage the tester and may cause the battery to explode!

illustration: When the charging indicator is red, it indicates that it is charging, and green indicates that the charging is completed.

Page 11: Multi-function Tester (TC-V2.12k)...2.5 Test zener diode When the shutdown or test is completed, the voltage stabilizing diode is put into the test area of the voltage stabilizing

Host x1,instructions x1。

4 FRQ

5 Packing list

Problem Description Problem causes Solution

Note①:Iceo、Ices、Uf only show when validNote②:Junction capacitance, reverse leakage current is only displayed when validNote③:Displayed only when there is a protection diodeNote④:ESR、Vloss only show when validNote⑤:Test inductance when single resistor and resistance is less than 2.1k

Fieldeffect tube

Silicon-controlled

Bidirectional thyristor

Capacitor

Resistance

The gate capacitance Cg, the leakage current under Vgs Id, the protection diode forward voltage drop Uf ③

JFET

IGBT

MOSFET

Gate trigger current<6mA

25pF-100mF

0.01-50M

Drain current Id under Vgs, protective diode forward voltage drop Uf 3Uf ③

Turn on voltage Vt, gate capacitance Cg, drain resistance Rds, protection diode forward voltage drop Uf ③

Gate voltage

Capacitance, equivalent series resistance ESR, dissipation factorVloss ④

Resistance

inductance 0.01mH-20H Inductor, DC resistance ⑤

Battery 0.1-4.5V Voltage value, battery polarity

Can not power on

Lithium battery without electricity

About charging the internal lithium battery, please refer to section 2.9 for charging method

Inaccurate results of

measurement

Inaccuracy of calibration parameters

Please recalibrate, refer to the 2.4 section