RIC Receiver Options Product Availability: SnapFit Receivers: Propel 312 RIC Receiver Summary: Propel The SnapFit Receiver simplifies replacement process and enhances the connection Available in Regular Lengths : 1, 2, 3, 4 and 5 The SnapFit mPower Custom Receiver (Embedded) option: Is available for 115/50, 123/60 and 130/70 receiver matrices Requires a CIC-type impression Impressions are scanned and stored for 36 months 115/50 Gain Receiver 120/60 Gain Receiver 123/60 Custom Gain Receiver 130/70 Gain Receiver Fitting Range Fitting Range Fitting Range Fitting Range Gain Selection Gain Selection Gain Selection Gain Selection MCL: 40 – 80dB 2kHz Threshold: 20 – 70dB MCL: 40 – 80dB 2kHz Threshold: 20 – 70dB MCL: 80 – 90dB 2kHz Threshold: 70 – 85dB MCL: 95+dB 2kHz Threshold: 90+dB Open Earbuds Open Earbuds Open Earbuds Open Earbuds Small Medium Large Small Medium Large Not Available Not Available Occluded Earbuds Occluded Earbuds Occluded Earbuds Occluded Earbuds Small Medium Large Small Medium Large Not Available Not Available Power Domes Power Domes Power Domes Power Domes 8mm 10mm 12mm 8mm 10mm 12mm Not Available Not Available mPower Custom Receiver mPower Custom mPower Custom
3
Embed
MT RIC Receiver options - Home | StarkeyPro RIC Receiver options.pdf · Requires a CIC-type impression ! Impressions are scanned and stored for 36 months 115/50 Gain Receiver 120/60
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
RIC Receiver Options Product Availability: Original Receivers: Propel Xino Tinnitus
RIC Receiver Summary: Propel Xino Tinnitus ä The Original Receiver requires the microphone cover be removed
prior to removing the receiver cable ä Available in Regular Lengths: 2-. 1-, 0, 1, 2, 3, 4 and 5 ä The Original mPower Custom Receiver (Embedded) option:
ä Is available for 115/50, 123/60 and 130/70 receiver matrices ä Requires a CIC-type impression ä Impressions are scanned and stored for 36 months
115/50 Gain Receiver 120/60 Gain Receiver 123/60 Custom Gain
Receiver 130/70 Gain Receiver
Fitt ing Range Fitt ing Range Fitt ing Range Fitt ing Range
Gain Selection Gain Selection Gain Selection Gain Selection
MCL: 40 – 80dB
2kHz Threshold: 20 – 70dB
MCL: 40 – 80dB
2kHz Threshold: 20 – 70dB
MCL: 80 – 90dB
2kHz Threshold: 70 – 85dB
MCL: 95+dB
2kHz Threshold: 90+dB
Open Earbuds Open Earbuds Open Earbuds Open Earbuds
Inspire Adjustments 1. Click on the Acoustic Options icon 2. Select Change Receiver Matrix 3. Choose Stock or Embedded receiver 4. Select Matrix 5. Click OK to save the changes
Fitting RIC and Custom Mould Order Process 1. Take an impression as if for a CIC device (4 mm past start of second
bend in ear canal if possible). 2. Choose appropriate cable length by holding Measurement Tool snugly to
ear and measure to top of tragus 3. Confirm measurement by placing that size cable on ear 4. Send impression and order form to Starkey Laboratories UK
The Acoustic Configuration selected in the software must match the configuration connected to the device in order to accurately reflect the hearing aid response.