Fire Alarm Systems | MS 400 Detector Base The detector head is installed in the Detector Base MS 400. The base is suitable for surface-mounted cable feeds as well as for flush-mounted cable feeds, and has separate attachment points for ceiling mount/flush-mounted back boxes. In addition, it fits all standard bore patterns. The Detector Base made of white ABS plastic (Novodur, color similar to RAL 9010) has a matt finish and seven terminal screws to connect the detector and its features to the fire panel. Contacts connected to the terminals guarantee a secure electric connection when the detector module is installed. Cables up to 2.5 mm 2 in diameter can be used. To protect against unauthorized removal, the detector head can be secured with a variable locking. Installation/Configuration Notes Installation information for 400/420 Series Detector Bases The drill holes marked with an "X" may only be used to mount the base to flush-mounted back boxes. Keep shielded auxiliary wire as short as possible, and make sure this is insulated. 100 14 22.7 7,8 120 +V 0V b1 b2 a a2 1/ c X X ca. 55 MS 400 Detector Base www.boschsecurity.com
2

MS 400 Detector Base - Bosch Security Systemsresource.boschsecurity.com/documents/Data_sheet_enUS...Fire Alarm Systems | MS 400 Detector Base The detector head is installed in the

Apr 21, 2018

Download

Documents

duongnhu
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: MS 400 Detector Base - Bosch Security Systemsresource.boschsecurity.com/documents/Data_sheet_enUS...Fire Alarm Systems | MS 400 Detector Base The detector head is installed in the

Fire Alarm Systems | MS 400 Detector Base

The detector head is installed in the Detector BaseMS 400.

The base is suitable for surface-mounted cable feeds aswell as for flush-mounted cable feeds, and has separateattachment points for ceiling mount/flush-mounted backboxes. In addition, it fits all standard bore patterns.

The Detector Base made of white ABS plastic (Novodur,color similar to RAL 9010) has a matt finish and seventerminal screws to connect the detector and its featuresto the fire panel.

Contacts connected to the terminals guarantee a secureelectric connection when the detector module is installed.

Cables up to 2.5 mm2 in diameter can be used.

To protect against unauthorized removal, the detectorhead can be secured with a variable locking.

Installation/Configuration Notes

Installation information for 400/420 Series DetectorBases• The drill holes marked with an "X" may only be used to

mount the base to flush-mounted back boxes.• Keep shielded auxiliary wire as short as possible, and

make sure this is insulated.

100

14

22.7

7,8

120

+V

0V

b1b2

aa21/c

X

X

ca.

55

MS 400 Detector Base

www.boschsecurity.com

Page 2: MS 400 Detector Base - Bosch Security Systemsresource.boschsecurity.com/documents/Data_sheet_enUS...Fire Alarm Systems | MS 400 Detector Base The detector head is installed in the

2 | MS 400 Detector Base

Technical Specifications

Connections Power supply (0 V, +V)LSN (a1/a2, b1, b2)C-pointShielding

Housing material ABS (Novodur)

Housing color Similar to RAL 9010

Dimensions Ø 120 x 22.7 mm

Weight 72 g

Ordering Information

MS 400 Detector Basefor surface-mounted and flush-mounted ca-ble feed

MS 400

Americas:Bosch Security Systems, Inc.130 Perinton ParkwayFairport, New York, 14450, USAPhone: +1 800 289 0096Fax: +1 585 223 [email protected]

Europe, Middle East, Africa:Bosch Security Systems B.V.P.O. Box 800025600 JB Eindhoven, The NetherlandsPhone: + 31 40 2577 284Fax: +31 40 2577 [email protected]

Asia-Pacific:Robert Bosch (SEA) Pte Ltd, Security Systems11 Bishan Street 21Singapore 573943Phone: +65 6258 5511Fax: +65 6571 [email protected]

Represented by

© Bosch Security Systems Inc. 2010 | Data subject to change without noticeT1825746827 | Cur: en-US, V27, 2 Dec 2010