Top Banner
Maipu Confidential & Proprietary Information Page 1 of 47 MP2800 Series Router Install Manual V1.2 Maipu Communication Technology Co., Ltd No. 16, Jiuxing Avenue Hi-Tech Park Chengdu, Sichuan Province P. R. China 610041 Tel: (86) 28-85148850, 85148041 Fax: (86) 28-85148948, 85148139 URL: http:// www.maipu.com Mail: [email protected] PDF 文件使用 "pdfFactory Pro" 试用版本创建 ÿ www.fineprint.com.cn
47

MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

Jan 02, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

Maipu Confidential & Proprietary Information Page 1 of 47

MP2800 Series Router Install

Manual

V1.2

Maipu Communication Technology Co., Ltd No. 16, Jiuxing Avenue Hi-Tech Park Chengdu, Sichuan Province P. R. China 610041 Tel: (86) 28-85148850, 85148041 Fax: (86) 28-85148948, 85148139 URL: http:// www.maipu.com Mail: [email protected]

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ÿ www.fineprint.com.cn

Page 2: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 2 of 47

All rights reserved. Printed in the People’s Republic of China. No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise without the prior written consent of Maipu Communication Technology Co., Ltd. Maipu makes no representations or warranties with respect to this document contents and specifically disclaims any implied warranties of merchantability or fitness for any specific purpose. Further, Maipu reserves the right to revise this document and to make changes from time to time in its content without being obligated to notify any person of such revisions or changes. Maipu values and appreciates comments you may have concerning our products or this document. Please address comments to: Maipu Communication Technology Co., Ltd No. 16, JiuXing Avenue, Hi-Tech Park Chengdu, Sichuan Province P. R. China 610041 Tel: (86) 28-85148850, 85148041 Fax: (86) 28-85148948, 85148139 URL: http:// www.maipu.com Mail: [email protected] All other products or services mentioned herein may be registered trademarks, trademarks, or service marks of their respective manufacturers, companies, or organizations.

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ( À www.fineprint.com.cn

Page 3: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 3 of 47

Maipu Feedback Form Your opinion helps us improve the quality of our product documentation and offer better services. Please fax your comments and suggestions to (86) 28-85148948, 85148139 or email to [email protected].

Document Title MP2800 Series Router Install Manual V1.2

Product Version

Document Revision Number

1.2

Presentation: (Introductions, procedures, illustrations, completeness, arrangement, appearance) £ Good £ Fair £ Average £ Poor

Accessibility: (Contents, index, headings, numbering) £ Good £ Fair £ Average £ Poor

Evaluate this document

Editorial: (Language, vocabulary, readability, clarity, technical accuracy, content) £ Good £ Fair £ Average £ Poor

Your suggestions to improve the document

Please check suggestions to improve this document: £ Improve introduction £ Make more concise £ Improve Contents £ Add more step-by-step procedures/tutorials £ Improve arrangement £ Add more technical information £ Include images £ Make it less technical £ Add more detail £ Improve index

If you wish to be contacted, complete the following:

Name Company

Postcode Address

Telephone E-mail

PDF 文件使用 "pdfFactory Pro" 试用版本创建 (耀 www.fineprint.com.cn

Page 4: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 4 of 47

Contents

Overview ......................................................................................................6 Key Features ..........................................................................................................6 Features.................................................................................................................7 Hardware...............................................................................................................9

MP2800 Appearance...................................................................................................................9 MP2800 Front Panel....................................................................................................................9 MP2800 Router Back Panel.......................................................................................................10 MP2800 Series Router System..................................................................................................11

Functions .............................................................................................................12

Modules ......................................................................................................15 Sync/Async Serial Interface Module (SAE) Series.....................................................15

11-port High-speed V.24/V.35 Serial Module (1SAE).................................................................15 Channelized E1 Module (CE1) Series.......................................................................16

1-port Channelized E1 Module (1CE1).......................................................................................16 Non-channelized E1 Module (E1) Series ..................................................................17

1-port Non-channelized E1 Module (1E1)..................................................................................17 Frequency-band MODEM M336 Series ....................................................................18

11-port 33.6K Frequency-band MODEM (1M336)......................................................................18 ISDN (U) Series....................................................................................................19

1-port ISDN U Module (1U) ......................................................................................................19 IP Module (VOP/VOS) Series..................................................................................20

1-port IP Phone Module (1VOP) ................................................................................................20 2-port IP Phone Module (2VOP) ................................................................................................21 1-port Switch IP Phone Module (1VOS).....................................................................................22 2-port Switch IP Phone Module (2VOS).....................................................................................23

Ethernet Module (ETE) Series.................................................................................24 1-port Ethernet Module (1ETE) .................................................................................................24

ISDN S/T Module (ST) Series.................................................................................25 11-port ISDN S/T Module (1ST)................................................................................................25

ISDN S/T Module (STA) Series...............................................................................26 1-port ISDN S/T Module (1STA) ...............................................................................................26

Asynchronous Serial Module (A) Series ...................................................................27 8-async Serial Module (8AX).....................................................................................................27

PDF 文件使用 "pdfFactory Pro" 试用版本创建 刀 www.fineprint.com.cn

Page 5: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 5 of 47

3G Series Module..................................................................................................28 RM2-3G-CDMA V2....................................................................................................................28

Installation.................................................................................................30 Security Suggestions.............................................................................................30 Environment Requirements....................................................................................30

Temperature & Humidity ..........................................................................................................31 Dust-free Environment .............................................................................................................31 Anti-static.................................................................................................................................32 Electromagnetic Environment Requirements.............................................................................32 Anti-lightning............................................................................................................................33

Check Routers & Accessories..................................................................................33 Tools & Equipment................................................................................................33

System Installation ...................................................................................35 Preparations.........................................................................................................35

Tools ........................................................................................................................................35 Checking Cabinet......................................................................................................................35 Checking Routers & Accessories................................................................................................36

Installing Router ...................................................................................................37 Main Control Board Cable Connection .....................................................................38

Console Port Connection...........................................................................................................38 Grounding Wire Connection ...................................................................................38 Connecting Power Supply ......................................................................................39 Module Installation................................................................................................40

Module Installation Steps..........................................................................................................40 Module Interface Cable Connection...........................................................................................40

Cables .........................................................................................................45 Ethernet Interface Cable........................................................................................45 Console Port Cable................................................................................................45 RM2-1E1 & RM2-1CE1 Using RJ45-RJ45 Crossover Twisted-Pair ...............................46

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 6: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 6 of 47

Overview

MP2800 series router developed by Maipu is the broadband-narrowband intelligent router integrating routing, switching, security, VoIP, transmission, local storage, and 3G, including MP2804, MP2806, MP2816 and MP2818 models. The router integrates the Maipu Multi-service Edge Intelligent Network (MEIN) technology to boost businesses. The series adopts fixed and modular structure, and provides broadband-narrowband, multi-service and intelligent solutions for users. The series has 100M packet-forwarding capacity from LAN to WAN. It can be used to access multi-Ethernet nodes such as network ends, PC and video monitor in finance, securities, insurance and government industries. The router provides many software features such as SNA/DLSw, VoIP, VPN, MPLS, multicast, MAC address binding, and access control and bandwidth restriction. The series provides backup schemes and QoS features. It can be applied to multiple services such as data, video and voice. The router series, combined with other Maipu routers, provides complete WAN network solutions for operator, finance, government, energy sources, traffic, education and military industries, and large/medium enterprises.

Key Features § Broadband-narrowband integration supports N*64K-100M lines

§

§ Intelligent multi-WAN load balance for coexistence of services

§

§ Provides intelligent NMS for automatically diagnosing router faults to realize ‘Zero-spot service’

§

§ Inbuilt hardware encryption technology ensures key services of finance system can be transmitted on IP lines

§

§ Each Ethernet port uses L2/L3 technology to realize flexible support for services

§

PDF 文件使用 "pdfFactory Pro" 试用版本创建 刀 www.fineprint.com.cn

Page 7: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 7 of 47

§ High-density Ethernet port and asynchronous port to access large-capacity Ethernet devices and traditional terminals

§

§ Hierarchical QoS ensures that the priorities of various services can be realized on specified bandwidth of MSTP 100M port

§

§ Compatible with the routers of the main manufacturers in the industry, which protects the original device investments and the reliable running of the whole network.

§ Supports MPLS and L2TPv3 to provide strict network area division for a single line bearing multiple services

§

§ Integrates routing, switching, security, voice, transmission, storage and wireless

§

§ Supports secure access control and compatible with products of main manufacturers

§

Features § Broadband-narrowband integration supports N*64K-100M lines

MP2800 extends features of Maipu broadband-narrowband routers and provides several high-speed multi-function slots to access N×64K, 2M and N×2M narrowband lines and realize MODEM and ISDN dial backup schemes. The fast-forwarding engine technology developed by Maipu makes WAN 100M line interface reach wire-speed forwarding supporting the extension of WAN line bandwidth to 100M in advance.

§

§ Intelligent multi-WAN load balance for coexistence of services Lower MP2800 series router assigns traffic to balance load by providing two or above lines on access/network nodes to reach one upper server. When some lines become invalid, traffics can be re-assigned to other lines.

§ Provides intelligent NMS for automatically diagnosing router

faults to realize ‘Zero-spot service’ Inbuilt dial-up modem/console port is connected to an external dial-up modem for remote login. Switch to remote configuration mode via button. Then users and manufacturers can maintain devices anywhere via telephone line dial-up to realize “Zero-spot service”. MP2800 supports Maipu intelligent NMS for diagnosing and fixing router faults, automatically generating a record for users to query. In this way, it reduces management and maintenance work of users considerably.

§ Inbuilt hardware encryption technology ensures key services of

finance system can be transmitted on IP lines

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 8: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 8 of 47

The router provides inbuilt and highly efficient hardware encryption engine. The encrypting data does not occupy bandwidth and CPU of the router system realizing that high-speed encryption does not affect data forwarding efficiency. For widely-used IP private line, encrypting data via WAN is the safest method of ensuring the security of important data.

§ Each Ethernet port uses L2/L3 technology to realize flexible support for services All Ethernet interfaces of MP2800 support L2/L3 technology to realize the control for different networking modes and services, avoiding poor control capacity caused by using Layer-2 switch and the problem that adopting routers occupies lots of IP addresses. In this way, we can simplify network configuration and strengthen management and control capacity of network for services.

§

§ High-density Ethernet port and asynchronous port to access large-capacity Ethernet devices and traditional terminals MP2816 and MP2818 models are configured with 2+24 100M Ethernet ports to access network terminals, PC and video terminals. Users do not need to purchase Ethernet switches, saving network investment and reducing faults. Considering there are some dumb terminals to access, MP2800 has extension slots which can be extended to up to 64 asynchronous interfaces to access traditional terminals and large-capacity Ethernet devices in network nodes/branch offices.

§ Hierarchical QoS

The priorities of various services can be realized on specified bandwidth of MSTP 100M port. MP2800 supports narrowband lines and MSTP/MPLS broadband lines. For MSTP/MPLS, the lines are for 100M interfaces, but in fact, the bandwidth applied by users is only a part such as 2M, 5M, 10M, 20M and 50M. Inconsistency between interface bandwidth and practical bandwidth results in traditional QoS becoming invalid. S0 MP2800 router adopts hierarchical QoS on Ethernet ports to realize bandwidth control first, and then secondary bandwidth allocation for different services. The QoS service of MP2800 router supports RSVP, CAR and queue policies such as FIFO, PQ, CQ, FQ, CBWFQ and LLQ to ensure priorities of key services.

§

§ Supports MPLS and L2TPv3 to provide strict network area division for a single line bearing multiple services MP2800 supports MPLS, L2TP and IPsec, which can be used to deploy VPN networks from Layer 2 to Layer 3. When branch offices are inter-connected by various lines, multiple services can be born on a single physical network to ensure the security and save cost.

§ Integrates routing, switching, security, voice, transmission, storage and 3G MP2800 integrates routing, switching, transmission, security, local storage and 3G. The series leads ways of edge routers - “Faster, more intelligent, more powerful”. The inbuilt intelligent switch, firewall, VPN (including MPLS VPN, IPsec VPN and L2TP VPN), VoIP and transmission

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ( www.fineprint.com.cn

Page 9: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 9 of 47

service modules construct a powerful intelligent platform for different service applications.

§

§ Supports secure access control and compatible with products of main manufacturers MP2800 is configured with inbuilt 802.1X and firewall. The series provides access authentication of users and network devices in branch offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The router is the first in China to realize SNA, DLSw and LLC2 protocols. It is compatible with network devices of main manufacturers in the industry.

§

§ Structure MP2800 series routers adopt 19’’ standard chassis (1U high) and can be installed on the standard cabinet. The optimized structural design has the features of anti-quake, anti high and low temperature, anti electromagnetic radiation and easy to assemble and disassemble, which makes the device work stably and reliably.

Hardware MP2800 Appearance

MP2800 Front Panel

SYS & PWR (system and power supply indicators):

§ SYS - System status indicator, shining slowly after loading successfully § PWR - System power supply indicator, on after power-on

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 10: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 10 of 47

§ CON/AUX (configuration/AUX port)

§ TXD - Configuration/AUX port data sending indicator § RXD - Configuration/AUX port data receiving indicator

§

§ FE0 (WAN Ethernet 0)

§ 100M - 10/100M Ethernet interface data rate indicator

§ On: 100M

§ Off: 10M

§ ACT - Ethernet interface data receiving/sending indicator

§

§ FE1 (WAN Ethernet 1)

§ 100M - 10/100M Ethernet interface data rate indicator

§ On: 100M

§ Off: 10M

§ ACT - Ethernet interface data receiving/sending indicator §

§ LAN Ethernet 0—23

§ 100M - 10/100M Ethernet interface data rate indicator

§ On: 100M

§ Off: 10M

§ ACT - Ethernet interface data receiving/sending indicator

MP2800 Router Back Panel

MP2800 series router back panel interface configuration MP2800 series router back panel interface: Device Type

Interface Interface Form Slot Description

ON/OFF Power supply switch - right OFF & left ON

MP2804

INPUT AC 100-240V 1A input

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 11: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 11 of 47

S0-S3 Decided by interface module

Multi-functional module

Multi-functional slot

ON/OFF Power supply switch - right OFF & left ON

INPUT AC 100-240V 1A input

S0-S1 Decided by interface module

Multi-functional module

Multi-functional slot

MP2806 MP2816

S2-S5 Decided by interface module

VOP/VOS, 8AX, 1STA modules

Private slots

ON/OFF Power supply switch - right OFF & left ON

INPUT AC 100-240V 1A input

MP2818

S0-S7 Decided by interface module

Multi-functional module

Multi-functional slot

• For the slots of MP2806 and MP2816, only VOP/VOS series voice card

module, 8AX, 1STA, and SM1 modules can be inserted. The multi-functional slots adopt modular design. Users can select different interface cards and the corresponding software modules as desired.

• 1ETE modules are supported only by multi-functional slots S0 and S1. • The 3G module is supported only by the slot S3 of MP2804, MP2806,

MP2816, and MP2818.

MP2800 Series Router System The basic configurations and working environment of MP2800 routers are as follows: Item Description

CON/AUX One (RJ45). Async DTE working mode

USB ports One

WAN Ethernet interface

Two 10/100M fast Ethernet interface (RJ45)

0 (MP2804) 0 (MP2806) LAN Ethernet interface

24 (MP2816) 24 (MP2818)

4 (MP2804) 2 (MP2806) High-speed multi-functional slot 2 (MP2816) 8 (MP2818)

0 (MP2804) 4 (MP2806) Private slot

4 (MP2816) 0 (MP2818)

0 (MP2804) 0 (MP2806) AIM slot

0 (MP2816) 1 (MP2818)

Processor High-speed RISC processor

MONITOR 512Kbytes

32Mbytes (MP2804) 32Mbytes (MP2806) FLASH

64Mbytes (MP2816) 64Mbytes (MP2818)

SDRAM 64Mbytes/128Mbytes/256Mbytes, optional

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 12: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 12 of 47

Dimension (W×D×H)

444mm×320mm×44.5mm

Maximum weight 5.7KG

Power supply input voltage

AC: 100-240V,50/60Hz AC: -40V--57V

Environment temperature

0-40℃

Environment humidity 10-90%, Non-condensing

Power supply rating power

70W (MP2818) 50W (MP2804, MP2806, MP2816)

Maximum power 27W±10% (MP2804) 35W±10% (MP2806) 42W±10% (MP2816) 52W±10% (MP2818)

Functions MP2800 routers support the following protocols and services:

Protocol & Service Description

Network protocol WAN supports: PPP PPP compression SLIP CSLIP protocol Frame relay Frame relay switching X.25 X.25 switching HDLC LAPB ISDN Virtual Ethernet bridge Bridge PPPoE LAN is Ethernet supporting two kinds of link layer frame: Ethernet-II Ethernet-SNAP

Dialup network MODEM dialup (calling/callout) CALLBACK Dial-on-demand Dialup backup

Routing protocol Static routing Dynamic routing: RIPv1 RIPv2 OSPF

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 13: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 13 of 47

BGP IS-IS IRMP Policy routing Multicast: IGMP PIM-SM PIM-SSM PIM-DM DVMRP Hot backup: VRRP VBRP (compatible with CISCO HSRP)

Network service ARP Proxy ARP IP UNNUMBERED EASY IP Load balance MPLS DHCP NTP

QoS service PQ CQ WFQ CBWFQ LLQ WRED CAR Traffic shaping

Network management SNMPv1、SNMPv2、SNMPv3 Supporting standard network management (compatible with CISCO) Local configuration via console port Local or remote login via local Telnet Configuration command security isolation function Chinese/English prompt and help information Detailed debugging information, for network malfunction elimination Log in and manage other products by Telnet Download and upload configuration file and application program via FTP Download and upload configuration file and application program via TFTP Colorful debugging information support Support log function

Security IP packet filter firewall Configuration command protect ensures that unauthorized users cannot invade the router. PAP/CHAP MD5

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 14: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 14 of 47

NAT RADIUS TACACS IPSEC data encryption AAA 802.1x

SNA GRE L2TP IKE

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 15: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 15 of 47

Modules

MP2800 series router is a modular router with three slots. The current interface modules include: § 1SAE § 1CE1 § 1E1 § 1M336 § 1U § 1VOP § 2VOP § 1VOS § 2VOS § 1ETE § 1ST § 8AX § 1STA § 3G § SM1

Sync/Async Serial Interface Module (SAE) Series 11-port High-speed V.24/V.35 Serial Module (1SAE) 1SAE module is used for MP2800 router. Its main function is to complete data flow receiving, sending and processing. For sync port, 2.048Mbps in DCE mode and 8 Mbps in DTE mode. For async port, 115.2Kbps. The working mode by default is in sync mode. In DTE mode, it uses clock from external DCE equipment such as external sync modem. But in DCE mode, router provides clock. V24/V35 switch is complete through panel buttons.

1SAE Interface Module 1SAE interface module:

PDF 文件使用 "pdfFactory Pro" 试用版本创建 (刀 www.fineprint.com.cn

Page 16: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 16 of 47

1-port high speed V.24/V.35 serial module (1SAE)

1SAE Module Connected Cable 1SAE module connected cable is V35 DTE and V24 DTE.

1SAE Interface Attributes 1-port high speed V.24/V.35 serial module (1SAE) interface attributes:

Description Attributes

Sync Async

Tie-in DB25-DB25 DB25-DB25

V.24 V.35 Interface standard & working mode DTE

DCE DTE DCE

EIA/TIA-232

Minimum BR (bps) 1200 1200 300

Maximum BR (bps) 128K 8M 115.2K

Dialup Backup

Protocol & Service X25 HDLC PPP SLIP FR LAPB

HDLC PPP SLIP

Channelized E1 Module (CE1) Series 1-port Channelized E1 Module (1CE1) The 1-port channelized E1 module provides multi-timeslot data flow port with total bus transmission rate 1984K. When used as CE1 interface, it can be divided into 1-31 timeslots, and each group works an interface after binding.

1CE1 Interface Module & Indicator 1CE1 interface module:

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ( www.fineprint.com.cn

Page 17: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 17 of 47

1-port channelized E1 module (1CE1) 1-port channelized E1 module (1CE1) indicator:

Indictor Meaning

LOS Lost indicator On: Cannot check sync signal Off: After sync

1CE1 Module Connected Cable Coaxial line with BNC pin and RJ45-RJ45 connected twisted-pair.

1CE1 Module Interface Attributes Attributes Description

Interface BNC, RJ45 (cannot be used at the same time)

Number of interfaces

One group for each

Interface standard G.703

Supported Protocol

PPP X.25 HDLC FR

Non-channelized E1 Module (E1) Series 1-port Non-channelized E1 Module (1E1) The 1-port non-channelized E1 module provides 2.048 Mbit/s data transmission port. E1 is same as CE1 interface, which can be divided into 32 timeslots physically. The timeslot 0 of E1 can be used for data transmission in unframed mode for 2M transparent transmissions.

1E1 Module & Indicator 1E1 module:

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ( www.fineprint.com.cn

Page 18: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 18 of 47

1-port non-channelized E1 module (1E1) 1-port non-channelized E1 module (1E1) indicator:

Indicator Meaning

LOS Always on: Transparent 2M transmission On: Non-transparent and cannot check frame sync signal Off: After sync

1E1 Interface Connected Cable Coaxial cable with BNC pin and RJ45-RJ45 connected twisted-pair.

1E1 Interface Attributes 1-port non-channelized E1 (1E1) attributes: Attributes Description

Interface BNC, RJ45 (cannot be used together)

Number of interfaces

One group for each

Interface standard G.703

Supported service X.25 FR

Supported protocol

PPP HDLC

Frequency-band MODEM M336 Series 11-port 33.6K Frequency-band MODEM (1M336) The 1-port 33.6K frequency-band MODEM supports sync or async mode. It can work in private line or dialup line mode. The modem can serve as the caller and callee. In sync mode, the clock mode includes internal clock, external clock and sub clock; the async mode includes direct async, buffer async, and error async.

PDF 文件使用 "pdfFactory Pro" 试用版本创建 (香 www.fineprint.com.cn

Page 19: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 19 of 47

1M336 Interface & Dialup DIP 1M336 Interface & Dialup DIP

1-port 33.6K frequency-band MODEM (1M336) 1-port 33.6K frequency-band MODEM (1M336) DIP:

DIP switch configuration Mode

1 2

Description

Frequency-band MODEM mode

OFF OFF LINE port is used as inbuilt frequency-band MODEM interface

Console port mode ON OFF LINE port is used as CONSOLE port Configure router via dialup remote login

1M336 Interface Module Connected Cable 1M336 module connected cable is RJ45 (4, 5 signal wire) or RJ11 telephone line.

1M336 Interface Attributes 1M336 interface attributes: 1-port 33.6K frequency-band MODEM (1M336) attributes: Attributes Description

Tie-in RJ45

Number of interfaces

1

Supported link protocol

PPP Frame relay X.25 HDLC

Supported network protocol

IP

ISDN (U) Series 1-port ISDN U Module (1U) 1-port ISDN U module connects DDN network and ISDN network. It will not connect modem.

PDF 文件使用 "pdfFactory Pro" 试用版本创建 (香 www.fineprint.com.cn

Page 20: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 20 of 47

1U Module & Indicator 1U module:

1-port ISDN U module (1U) 1-port ISDN U module (1U) indicator: Indicator Meaning

ACT Activated indicator and it is on when running normally

B1 B1 channel indicator, and it is on when using channel B1, with the rate of B1=64K or B1+B2=128K

B2 B2 channel indicator, and it is on when using channel B2, with the rate of B2=64K or B1+B2=128K

1-port ISDN U module (1U) DIP switch:

DIP switch configuration Mode

1 2

Description

Loopback ON Reserved

1U Module Connected Cable 1U module connected cable is RJ45 (4, 5 signal cable) or RJ11 line.

1U Interface Attributes 1-port ISDN U module (1U) interface attributes: Attributes Description

Tie-in RJ45

Number of interfaces 1

Supported link protocol PPP

Supported network protocol

IP

IP Module (VOP/VOS) Series 1-port IP Phone Module (1VOP) The 1-port IP phone module can access any telephone in IP network through dialup. You can easily make a free phone call by using the set IP network, constructing value-added network.

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ( www.fineprint.com.cn

Page 21: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 21 of 47

1VOP Module &Indicator 1VOP interface module:

1-port IP phone module (1VOP) indicator: Indicator Meaning

V1 IP phone module indicator. The light is on during the call after picking up the phone.

V2 1VOP module may not have this light. If it has, the light will be not on

1VOP Module Connected Cable 1VOP module connected cable is RJ45 (4, 5 signal cable) and RJ11 line.

1VOP Interface Attributes 1-port IP phone module (1VOP) interface attributes: Attributes Description

Interface RJ45 jack

Number of interfaces

1

Supported protocol

H.225 H.245 RTP RTCP G.711 G.723 G.729

2-port IP Phone Module (2VOP) The 2-port IP phone module can access any telephone in IP network through dialup. You can easily make a free phone call by using the set IP network, constructing value-added network.

2VOP Module & Indicator 2VOP module:

PDF 文件使用 "pdfFactory Pro" 试用版本创建 香 www.fineprint.com.cn

Page 22: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 22 of 47

2-port IP phone module (2VOP) 2-port IP phone module (2VOP) indicator: Indicator Meaning

V1 IP phone module indicator Light on: After pickup, during the call

V2 IP phone module indicator Light on: After pickup, during the call

2VOP Module Connected Cable 2VOP module connected cable is RJ45 external cable.

2VOP Module Interface Attributes 2-port IP phone module (2VOP) interface attributes: Attributes Description

Interface RJ45 jack (two RJ11 plugs)

Number of interfaces

2 (RJ11)

Supported protocol

H.225 H.245 RTP RTCP G.711 G.723 G.729

1-port Switch IP Phone Module (1VOS) The 1-port switch IP phone module can access any telephone in IP network through dialup. You can easily make a free phone call by using the set IP network, constructing value-added network.

1VOS Module & Indicator

1-port switch IP phone module (1VOS) 1-port switch IP phone module (1VOS) indicator: Indicator Meaning

V1 IP phone module indicator Light on: during the phone call

V2 1VOS module may not have this lamp

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 23: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 23 of 47

Otherwise, the lamp will never be on

1VOS Module Connected Cable 1VOS module connected cable is RJ45 (4, 5 signal cable) and RJ11 telephone line.

1VOS Interface Attributes 1-port switch IP phone module (1VOS) interface attributes: Attributes Description

Interface RJ45 jack

Number of interfaces

1

Supported protocol

H.225 H.245 RTP RTCP G.711 G.723 G.729

2-port Switch IP Phone Module (2VOS) The 2-port switch IP phone module can access any telephone in IP network through dialup. You can easily make a free phone call by using the set IP network, constructing value-added network.

2VOS Module & Indicator 2VOS module:

2-port switch IP phone module (2VOS) 2-port switch IP phone module (2VOS) indicator: Indicator Meaning

V1 IP phone module indicator. Light on: During the phone call

V2 IP phone module indicator. Light on: During the phone call

2VOS Module Connected Cable 2VOS module connected cable is RJ45 external line.

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ( www.fineprint.com.cn

Page 24: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 24 of 47

2VOS Module Interface Attributes 2-port switch IP phone module (2VOS) interface attributes: Attributes Description

Interface RJ45 jack (two RJ11 plugs)

Number of interfaces

2 (RJ11)

Supported protocols

H.225 H.245 RTP RTCP G.711 G.723 G.729

Ethernet Module (ETE) Series 1-port Ethernet Module (1ETE) 1-port Ethernet module realizes Ethernet connection.

1ETE Module & Indicator 1ETE module:

1-port Ethernet module (1ETE) 1-port switch IP phone module (1ETE) indicator: Indicator Meaning

LINK On: Link connected

Tx Data sending light shining: Data sending

Rx Data receiving light shining: Data receiving

1ETE Module Connected Cable RJ45 twisted-pair

1ETE Module Interface Attributes 1ETE module interface attributes: 1-port Ethernet port (1ETE) attributes: Attributes Description

PDF 文件使用 "pdfFactory Pro" 试用版本创建 香 www.fineprint.com.cn

Page 25: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 25 of 47

Tie-in RJ45

Number of tie-ins 1

Supported protocol 802.3

ISDN S/T Module (ST) Series 11-port ISDN S/T Module (1ST) 1-port ISDN S/T (1ST) module provides 64K or 128K high-speed access and backup.

1ST Module & Indicator 1ST module:

1-port ISDN S/T module (1ST) 1-port ISDN S/T module (1ST) indicator Indicator Meaning

ACT Activated indicator and it is on when running normally

B1 B1 channel indicator, and it is on when using channel B1, with the rate of B1=64K or B1+B2=128K.

B2 B2 channel indicator, and it is on when using channel B2, with the rate of B2=64K or B1+B2=128K.

1ST Module Connected Cable 1ST cable is RJ45 straight-through cable.

1ST Module Interface Attributes 1-port ISDN S/T module (1ST) interface attributes: Attributes Description

Tie-in RJ45

Number of tie-ins 1

Supported protocol PPP

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 26: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 26 of 47

ISDN S/T Module (STA) Series 1-port ISDN S/T Module (1STA) 1-port ISDN S/T (1STA) module provides 64K or 128K high-speed access and backup. It is the hardware upgrade version of 1-port ISDN S/T (1ST) module with great slot compatibility and can be inserted to all the slots of MP2800 routers. It also has all the software and hardware functions of 1-port ISDN S/T (1ST) module.

1STA Module & Indictor 1STA module:

1-port ISDN S/T module (1STA) 1-port ISDN S/T module (1STA) indicator:

Indicator Meaning

ACT Activated indicator and it is on when running normally

B1 B1 channel indicator, and it is on when using channel B1, with the rate of B1=64K or B1+B2=128K

B2 B2 channel indicator, and it is on when using channel B2, with the rate of B2=64K or B1+B2=128K

1STA Module Connected Cable 1STA cable is RJ45 straight-through cable.

1STA Module Interface Attributes 1-port ISDN S/T module (1STA) interface attributes:

Attributes Description

Tie-in RJ45

Number of tie-ins 1

Supported protocol PPP

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 27: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 27 of 47

Asynchronous Serial Module (A) Series 8-async Serial Module (8AX) The 8-async module main function is to complete its data flow receiving and sending only in asynchronous mode and the rate reaches 115.2K.

8AX Module 8AX interface module:

8-async serial module (8AX)

8AX Module Connected Cable 8AX module connected cable is 8-async serial cable.

8AX Interface Attributes 8-async serial module (8AX) interface attributes: Attributes Description

Tie-in DB60

Interface standard RS-232

Minimum BR (bps) 300

Maximum BR (bps) 115.2K

Supported services Terminal (with terminal number fixed function) ATM PC working station Router Frequency-band or base-band modem PC or router dialup Other serial equipment

Supported protocols X.25 HDLC PPP SLIP

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ( www.fineprint.com.cn

Page 28: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 28 of 47

3G Series Module The RM2-3G module realizes the wireless 3G function and it can only be inserted in the S3 slot of the MP2800 series router. It includes RM2-3G-CDMA V2 and RM2-3G-GSM V2. ANT0 and ANT1 on the front panel are the antenna pedestal of the 3G module respectively.

RM2-3G-CDMA V2 The RM2-3G-CDMA V2 module needs to be inserted with the CDMA2000 3G module and USIM card.

RM2-3G-CDMA V2 Module and Indicators RM2-3G-CDMA V2 module:

The indicators of RM2-3G-CDMA V2 module:

Indicator Color Meaning

Off: Not power on WWAN Green

On: Power on

Off: Weak signals <= -116dBm

On: Strong signals >= -78dBm RSSI Green

Flash: -78dBm > Middle/low signals > -116dBm

Off: No 1xRTT service 1xRTT Green

On: With 1xRTT service

Off: No EVDO service EVDO Green

On: With EVDO service

RM2-3G-GSM V2 The RM2-3G-GSM V2 module needs to be inserted with WCDMA 3G module and USIM card.

RM2-3G-GSM V2 Module and Indicators The RM2-3G-GSM V2 module:

The indicators of the RM2-3G-GSM V2 module:

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ( www.fineprint.com.cn

Page 29: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 29 of 47

Indicator Color Meaning

Off: Not power on

On: With service, but not enter the data mode

WWAN Green

Green and flash slowly: Searching service (off for 4.75s and on for 0.25s.

Green and flash quickly: with service and enter data mode (The quick flashing frequency is related with received data traffic. The larger the data traffic, the faster the flashing. When there is no traffic, flash with an interval of 4s).

Off: Weak signals <= -103dBm

On: Strong signals >= -55dBm RSSI Green

Flash: -55dBm > Middle/low signals > -103dBm

Off: No HSDPA service HSDPA Green

On: With HSDPA service

Off: No GSM/GPRS service UMTS Green

On: With GSM/GPRS service

SM1 Module The RM2-SM1 module is used for the hardware encryption and decryption. The RM2-SM1 module panel does not have external interfaces.

RM2-SM1 Module The RM2-SM1 interface module:

The meanings of the RM2-SM1 module indicators: ACT On: Some data is encrypted/decrypted

Off: Idle

RDY On: The card is available, that is, RDY and ENABLE are valid at the same time

Off: The card is unavailable

Flash: The card is RDY, but the host is not enabled (Enable)

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ( www.fineprint.com.cn

Page 30: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 30 of 47

Installation

Security Suggestions To avoid the harms on persons and equipments caused by various accidents, comply with the following: § Keep the router far away from humid places and heat

§

§ Ensure that router is well grounded

§

§ Wear anti-static wrists during installation and maintenance

§

§ Do not install, move and dismantle routers and modules during power on to avoid damages on persons and equipments

§

§ Do not hot swap interface modules and interface cards of routers

§

§ Do not hot swap cables

§

§ Connect the interface cables of routers correctly, especially do not connect phone lines (including ISDN lines) to serial ports

§

§ Use Uninterrupted Power Supply (UPS)

§

§ Router AC power supply is soft start control switch, which does not cut the main return circuit of AC power supply. During installation, the control switch of main return circuit so as to cut down power supply fast in case of accidents.

Environment Requirements MP2800 series routers must be used indoor. To guarantee stable use of routers, the application scenario must meet the following requirements.

PDF 文件使用 "pdfFactory Pro" 试用版本创建 (刀 www.fineprint.com.cn

Page 31: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 31 of 47

Temperature & Humidity To ensure the service quality and life of MP2800 series routers, it is recommended to maintain a certain temperature and humidity in the computer lab. If the humidity in the computer lab is high for long time, it causes the poor insulation and even electricity leak of insulation materials easily. Sometimes, the mechanical performances of materials change and the metal parts are corroded easily, too. If the relative humidity is too low, insulation pads shrink, which causes the fastened screws loose. Meanwhile, in dry environment, static electricity appears easily, which harms the circuits on the router. If the temperature is too high, the reliability of the router reduces greatly. The long-time high temperature affects the life and speeds up the aging of insulation materials.

The recommended temperature and humidity in computer room: Temperature Relevant humidity Long-term Short-term Long-term Short-term

15℃-30℃ 0℃-40℃ 40%-65% 10%-90%

§

§ Measuring points of the working temperature and humidity of MP2800 in the computer room mean the values measured from the floor above 1.5 m and 0.4 m from the front of the rack when there are no protection boards.

§

§ The short-term working condition means less than 48h continuously and less than 15 days for the annual total.

§

§ Extreme adverse working environment means the environment temperature and humidity when the air-conditioning system in the computer room fails. Each time the normal work should be recovered within less than 5h.

Dust-free Environment Dust is harmful for MP2800 operation. Dust causes static absorption, which makes the poor contact of metal pieces. Static absorption appears especially when the temperature and humidity are lower, which affects the device life and causes communication fault. Dust requirements for the room: Maximum diameter (μm) 0.5 1 3 5 Maximum concentration (contained particles per m

3)

1.4×107 7×105 2.4×10

5 1.3×10

5

PDF 文件使用 "pdfFactory Pro" 试用版本创建 (香 www.fineprint.com.cn

Page 32: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 32 of 47

Apart from dust, the router has strict requirements for SO2, H2S, NH3, and Cl2 in the room, because these harmful gases speed up the eroding of metals and the aging of some components. The specific limitations are as follows: Gas Maximum value (mg/m

3)

SO2 0.2

H2S 0.006

NH3 0.05

Cl2 0.01

Anti-static MP2800 router takes lots of measures in anti-static, but when the static exceeds a certain volume, the circuits even the whole monitor are damaged. For router communication, static electricity originates from external electric field of high-pressure like electricity cables and thunders, and internal system such as floor material and chassis structure. To prevent the damage caused by the static, do as follows: § Ensure proper equipment grounding

§

§ Maintain dustproof room

§

§ Keep suitable temperature & humidity

§

§ Wear anti-static equipment

§

§ Place the disassembled circuit board on the anti static workstation and keep the face upturned or in the anti static bag

§

§ When viewing or removing the disassembled circuit board, touch the edge of circuit board and avoid touching the components on the circuit board.

Electromagnetic Environment Requirements The various interference sources, no matter from the exterior of devices or application systems or from the interior, affect the devices through capacitance coupling, inductance coupling, electromagnetic radiation, public impedance (including grounding system) and lead (such as power lines, signal lines and output lines).

PDF 文件使用 "pdfFactory Pro" 试用版本创建 (香 www.fineprint.com.cn

Page 33: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 33 of 47

Therefore, pay attention to the following: § Take anti-electric network interference for power system.

§

§ The router working place had better not be used with the grounding settings of power devices or anti-thunder grounding settings and the distance between them had better be as long as possible.

§

§ Be away from the strong power radio transmitters, radar transmitter, and high frequency high-current equipments.

§

§ Take electromagnetic shielding methods when necessary.

Anti-lightning MP2800 router takes lots of measures in anti-lightning, but when the lightning exceeds a certain volume, the router may be damaged. To prevent the damages caused by lightning, do as follows: § Ensure that the protect ground of the chassis is well grounded;

§

§ Ensure that the grounding point of AC power supply jack is well grounded;

§ Add power lightning arrester to the input end of the power supply, so as to improve the anti-lightning capability of the power supply;

§

§ To improve the anti lightning capability, the MP2800 interface modules are connected to outdoor signal lines. You can add special anti-lightning equipment to the input end of signal lines.

Check Routers & Accessories After ensuring the installation environment requirements are met, you can open the package. However, before installation, check whether the router and the accessories are complete according to the purchase order.

Tools & Equipment Tools § Slotted point screwdriver/cross point screwdriver

§

§ Level, ruler or tapeline

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ( www.fineprint.com.cn

Page 34: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 34 of 47

§

§ Anti-static equipment Connected cables § Cables in the package Equipment § HUB or Ethernet switch

§

§ Configuring terminal (can be PC)

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ( www.fineprint.com.cn

Page 35: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 35 of 47

System Installation

Preparations Tools Before installation, prepare slotted point screwdriver/cross point screwdriver, level, ruler or tapeline, and anti-static equipment

Checking Cabinet Maipu devices are designed according to the dimension of 19-inch standard cabinet, so they can be installed and fixed normally on 19-inch standard cabinet. Before installation, reserve enough slot room for installing the device. Center distance of the horizontal installation hole and net horizontal direction installation space of the cabinet

Use ruler or tapeline to measure the center distance of the horizontal installation hole and net horizontal installation space of the cabinet. Check whether the pallet bracket, floating nut, fixed screw, and baffle

PDF 文件使用 "pdfFactory Pro" 试用版本创建 (刀 www.fineprint.com.cn

Page 36: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 36 of 47

board on the cabinet are complete, which are the standard accessories. Different cabinets have different dimensions and shapes. Therefore, to add cabinet accessories, contact the supplier of the cabinet to provide genuine accessories. The device must be installed on the pallets or trays (used in pairs) of the cabinet. Therefore, install the pallets or trays on the cabinet before installing the device as follows. Use the level to check whether the pallets or trays are horizontal. If not, adjust the fixed bolt of pallet or tray to make the pallet or tray horizontal and then fasten it.

Check whether the floating nut for fixing the device is installed in the square hole of the cabinet column. If not, insert the floating nut to the square hole according to the position of the pallet or tray. Usually, it is required that one device is placed on a pallet or a bracket. It is not recommended to overlap multiple devices.

Checking Routers & Accessories After ensuring the installation environment requirements are met, open the package and check whether the router and the accessories are complete according to the purchase order.

§

§ If there is some missing or damaged items in the package, contact the equipment dealer or sales.

§

§ During check, place router and accessories at safe place to avoid falling down or impacting; keep the router far away from the places with liquids, toxic gases and dust to avoid damages on the router.

§

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 37: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 37 of 47

§ When moving or checking the device, wear gloves to avoid the corrosion of metal parts caused by perspiration.

§

§ Keep all packaging materials for later use during transporting.

Installing Router Install MP2800 router to the cabinet as follows.

§

§ Step 1: Wear gloves and anti-static wrist and make the anti-static reliable grounding

§

§ Step 2: Place the device on the fixed platform. Align the installation hole of the bracket and the corresponding place of the device. Use the screw to fix the bracket on the two sides of the device.

§ Step 3: The front of the device faces the operator. Use the hands to stabilize the device and keep it horizontal. Place the device from the cabinet front to the pallet or bracket carefully and avoid that the device hits the cabinet columns. For the heavy or high device, two persons had better cooperate to handle it.

§

§ Step 4: Use two hands to push the device and make the bracket of the device close to the surface of the cabinet column.

§

§ Step 5: Use fixed screw to install the device on the column of the cabinet.

§

§ Step 6: Check whether the device is installed on the bracket fixedly and straight.

§

§ Step 7: Check the space between the installed devices. Choose the desired cabinet baffle board (it is the standard accessory of the shelf) to be placed in the space between the devices. Use the screws to fix baffle board on the shelf.

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 38: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 38 of 47

Installation suggestions: When installing various devices on a cabinet, consider installing heavy devices at the bottom of the cabinet or close to the bottom so as to lower the cabinet’s center of gravity and improve the stability. When installing devices in the cabinet, it is recommended to reserve a space of 1U height between devices to ensure the space for heat dissipation of devices. Install the baffle board configured with the cabinet in the space between devices.

Main Control Board Cable Connection This section describes the method of connecting MP2800 control board cables to the network, including connecting router console port.

Console Port Connection MP2800 router provides one EIA/TIA-232 async serial console port. The user configures the router via the port by adopting RS-232 serial character terminal (normally a PC). For the detailed connection and configuration, refer to the later chapter. Configure the router via the terminal as follows: § Step 1: Find a character terminal – a standard terminal with RS-232

serial or normal PC. The latter is more common. § Step 2: Ensure that router or terminal is out of power supply and

connect RS-232 serial and console port with cables. During the connection, make sure about the ID on the interface to avoid inserting to other interfaces.

Grounding Wire Connection The normal connection of MP2800 ground wire is the first guarantee of anti-thunder and anti-interference of the router. It is required that users must connect the ground wires correctly. AC noise filter is connected to the AC input end of router power supply, whose center is connected with chassis. The chassis ground (that is protect ground) must be connected to the ground, so as to make induction electricity and leaked electricity flow to the earth and improve the feature of anti electromagnetic interference. For external network connection such as E1 interface, grounding cable protects the PSTN. The grounding wire also protects the thunder high

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ( www.fineprint.com.cn

Page 39: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 39 of 47

voltage from the external network connection such as E1 interface and PSTN. Connect this point and ground it by a thick cable with resistance not bigger than 4Ω. If the router is installed on 19-inch standard cabinet, the cabinet should be grounded.

Connecting Power Supply MP2800 router adopts stable power supply switch system and has a low requirement for input AC. In China, adopt 220V and 50Hz AC, which is a civilian electricity standard. Different areas have different power supply systems. MP2800 router input power supply requirements are as follows:

§

§ AC input power supply: 100-240V, 50/60Hz § DC input power supply: -40--57V § Maximum power: 27W±10% (MP2804) § 35W±10% (MP2806) § 42W±10% (MP2816) § 52W±10% (MP2818) When connecting power supply, use the below suggested power supply jack or MIM PC power supply jack for reliable grounding. When laying cables for buildings, the ground wires of the power supply system have been installed underground. Users should ensure the reliable grounding and make the corresponding processing.

Ground wire

Live wireNaught wire

Common power supply jack

Connect the power supply as follows: § Step 1: Put the power supply switch to OFF. For AC router, connect

one side of AC power supply cable to the AC power input end of the back panel of the router and another side to power supply jack (AC: 220V 50Hz/60Hz) and use the clip to lock the cable; for DC router, connect the power line to the post according to the description of panel silk screen on the interface. The cross sectional area of the lead of the selected power line must be larger or equal to 2 mm2.

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 40: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 40 of 47

§ Step 2: Put power supply switch to ON. § Step 3: Check whether the power supply indicator of the front panel is

on. If not, repeat step 1 and 2. If the power supply indicator is not on after repeating the above steps, contact the agent.

Module Installation Module Installation Steps MP2800 series router adopts modular structure and provides the capacities of configuring various interfaces according to users’ requirements. The installations of various modules are simple and convenient, as follows.

Installing MP2800 series modules

The steps for installing modules: § Choose the desired modules and interfaces (for the corresponding

relationship of modules and slots, refer to the interface table of the back panel of MP2800 router).

§

§ Insert the module to slot. Insert the module circuit board into interface card slot.

§

§ Push in the module close to back panel.

§

§ Tighten the screw. According to the contrary order, you can dismantle the modules.

Module Interface Cable Connection 1SAE Module Interface Cable Connection This section describes the notes of 1SAE module and cable connection. Before connecting sync/async serial, ensure the following two points: § The equipment type connecting sync/async serial, which is sync/async

or DTE/DCE

§

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 41: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 41 of 47

§ Access equipment requires signal standard, baud rate and sync clock.

§

DTE and DCE:

Sync/async serial port accesses external Modem or TA (terminal adapter) as dialup interface. Sync serial port has two modes - DTE and DCE. The two direct connected devices work in DTE and DCE respectively. The device at the DCE side provides the synchronization clock and specifies the communication rate, while DTE device receives the synchronization clock and communicate according to the specified baud rate. The router usually serves as DTE. For the type of the device connected to the router, refer to the manual of the device. The following table can also help you determine the device type. Typical DTE and DCE equipment: Device Type Interface Type Typical Device

DTE Pin type PC router

DCE Hole type MODEM Multiplexer CSU/DSU

Rate and transmission distance: Sync/async serial supports different signal standards and baud rates in different working modes. Choose cables as per prevailing conditions. The maximum transmission distance and baud rate of signals are related with the cables. V.24 cable rate and transmission distance: Baud rate (bps) Maximum transmission distance (m)

2400 60

4800 60

9600 30

19200 30

38400 20

64000 20

115200 10 V.35 cable rate and transmission distance: Baud rate (bps) Maximum transmission distance (m)

2400 1250

4800 625

9600 312

19200 156

38400 78

56000 60

PDF 文件使用 "pdfFactory Pro" 试用版本创建 香 www.fineprint.com.cn

Page 42: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 42 of 47

64000 50

2048000 30

When EIA/TIA-232 cable is adopted, BR rate cannot be over 64Kbps. Connect the cables of synchronous/asynchronous modules as follows: § Step 1: Insert one side of DB-25 to the DB-25 interface of 1SAE

module and screw down fixed knob. § Step 2: Connect another DB25 interface to V.24-V.35 (DB-25, M-34)

cable and then connect the following equipment: If WAN is DDN line, connect (V.35 cable) to digital Modem V.35 interface. If WAN is dialup line, connect (V.24 cable) to analog Modem serial. During the connection, make sure about the ID on the interface to avoid inserting to other interfaces, which causes the damage of modules and router host.

1CE1/1E1 Module Interface Cable Connection Connect 1CE1/E1 interface as follows: § Step 1: Connect one side of BNC plug to BNC interface of 1CE1/E1

module.

§

§ Step 2: Connect another side to the corresponding equipment. Connect TX to RX equipment. Connect RX to TX line.

§ Step 3: After power on, check LOS status of 1CE1/E1 module.

Indicator on means malfunction and signal loses sync. Then check the line. In E1 transparent 2M mode, the asynchronous indicator is always on.

For RJ45 interface, use RJ45-RJ45 crossover twisted pair to connect. BNC and RJ45 interface cannot be used together.

§ During the connection, make sure about the ID on the interface to avoid inserting to other interfaces, which causes the damage of modules and router host.

§

§ For E1 module, asynchronous indicator is always on in transparent 2M mode; in non-transparent mode, the indicator is on when frame synchronous signals are not checked. After synchronization, the indicator is off.

1M336 Module Interface Cable Connection Insert RJ11 plug of 1M336 module cable to LINE jack. During the connection, make sure about the ID on the interface to avoid inserting to other interfaces, which causes the damage of modules and

PDF 文件使用 "pdfFactory Pro" 试用版本创建 (香 www.fineprint.com.cn

Page 43: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 43 of 47

router host.

1U Module Interface Cable Connection § Step 1: Insert RJ11 plug of 1U cable to LINE jack. Connect another

side to the external lines. § Step 2: After power on, please check ACT status of 1U interface

module. If the indicator is off, please check the line. During the connection, make sure about the ID on the interface to avoid inserting to other interfaces, which causes the damage of modules and router host.

1VOP/2VOP Module Interface Cable Connection Step 1: Insert telephone line to RJ11 interface of 1VOP/2VOP, and another side to telephone. Step 2: When having the phone call, pay attention to the indicator of 1VOP/2VOP card back panel. During the call, the indicator of each channel should be on. During the connection, make sure about the ID on the interface to avoid inserting to other interfaces, which causes the damage of modules and router host.

1VOS/2VOS Module Interface Cable Connection § Inset telephone line to RJ11/RJ45 interface of 1VOS/2VOS and another

side to small switch or external junction box. § When having the phone call, pay attention to the indicator of

1VOS/2VOS card back panel. During the call, the indicator of each channel should be on.

During the connection, make sure about the ID on the interface to avoid inserting to other interfaces, which causes the damage of modules and router host.

1ETE Module Interface Cable Connection § Inset RJ45 plug of 1ETE cable to RJ45 jack. § Connect another side of RJ45 plug to equipment wire.

§

§ During the connection, make sure about the ID on the interface to avoid inserting to other interfaces, which causes the damage of modules and router host.

1ST/1STA Module Interface Cable Connection § Inset RJ45 plug of 1ST/1STA cable to RJ45 jack.

PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.com.cn

Page 44: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 44 of 47

§ Connect another side of RJ45 plug to equipment wire.

8AX Module Interface Cable Connection § Inset DB60 plug of 8AX cable to 8AX jack. Screw down the fixed knob § Connect another side of RJ45 plug to equipment wire. During the connection, make sure about the ID on the interface to avoid inserting to other interfaces, which causes the damage of modules and router host.

PDF 文件使用 "pdfFactory Pro" 试用版本创建 ( www.fineprint.com.cn

Page 45: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 45 of 47

Cables

Ethernet Interface Cable MP2800 Ethernet interface cable is 8-core non-screen twisted-pair. Silver plate1/2 are sending end and silver plat 3/6 are receiving end. RJ45 straight connected cable (type-5 twisted-pair) connection relation: RJ45 Signal Direction RJ45 Description Length 1 TX0+ —> 1 2 TX0- —> 2

Twisted-pair 1

3 RX0+ <— 3 6 RX0- <— 6

Twisted-pair 2

4 ---- ---- 4 5 ---- ---- 5

Twisted-pair 3

7 ---- ---- 7 8 ---- ---- 8

Twisted-pair 4

2m

RJ45 cross cable (type-5 twisted-pair) connection relation:

RJ45 Signal Direction RJ45 Description Length

1 TX+ —> 3

2 TX- —> 6 Twisted-pair 1

3 RX+ <— 1

6 RX- <— 2 Twisted-pair 2

4 --- --- 7

5 --- --- 8 Twisted-pair 3

7 --- --- 4

8 --- --- 5 Twisted-pair 4

2m

Console Port Cable MP2800 console port cable is connected with PC 9-core serial jack, and it is 8-core non-screen cable. One side is RJ45 plug and another is DB9 (hole).

PDF 文件使用 "pdfFactory Pro" 试用版本创建 (香 www.fineprint.com.cn

Page 46: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 46 of 47

RJ45 jack Standard DB9 interface

Console port cable connection relation:

RJ45 Signal Direction DB9 Length

1 CTS —> 8

2 DSR —> 6

3 RXD —> 2

4 GND --- 5

5 --- --- ---

6 TXD <— 3

7 DTR <— 4

8 RTS <— 7

--- --- 1

--- --- 9

3m

RM2-1E1 & RM2-1CE1 Using RJ45-RJ45 Crossover Twisted-Pair If RJ45-RJ45 crossover twisted-pair is needed when using RJ45 interface of E1 and CE1 cards, make the cables according to the cable sequence described in the following table. RJ45 Signal Direction RJ45

1 RX+ <— 4

2 RX- <— 5

3 --- --- 7

6 --- --- 8

4 TX+ —> 1

5 TX- —> 2

7 --- --- 3

PDF 文件使用 "pdfFactory Pro" 试用版本创建 香 www.fineprint.com.cn

Page 47: MP2800 Series Router Install Manual V1.2 · offices and supports ACL packet filtering, NAT, certification audit, routing verification, callback and refusing service protection. The

MP2800 Series Router Install Manual V1.2

Maipu Confidential & Proprietary Information Page 47 of 47

8 --- --- 6

RJ45 interface cable sequence

PDF 文件使用 "pdfFactory Pro" 试用版本创建 (香 www.fineprint.com.cn