Top Banner

of 32

Motor Baldor Data Sheet

Apr 12, 2018

Download

Documents

eraguilar
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • 7/22/2019 Motor Baldor Data Sheet

    1/32

    Baldor

    Large Frame AC

    Induction Motors

  • 7/22/2019 Motor Baldor Data Sheet

    2/32www.baldor.com1

    Why Baldor?For over 85years, Baldor hasstrived to providecustomers with

    the best valueand reliability inindustrial electricmotors. Thatdedication showsin customerpreference forBaldor motors.

    To be consideredas the mostpreferred...

    Baldor offers the industrys broadest line of stock

    products. Save valuable time with just one call toBaldor. We offer more than 7,000 stock motors, drives,generators and gearboxes.

    Energy-efficiency leader. We began lowering theenergy consumption of our motors in the 1920s, longbefore others were even talking about it. Today, ourexpansive line of Super-Epremium-efficient motorsranges from 1 through 1250 hp. Baldors Super-Elineoffers customers the highest overall efficiency levelsin the industry.

    Baldor products are

    available at more locations

    than any other brand.

    Our 35 district officesacross North America offerimmediate availability ofBaldor products to thousandsof distributors.

    Continuous innovation to improve reliability.

    Baldor leads the motor industry in applying newtechnologies and materials to improve motor reliability.

    Baldor was the first to introduce ISR

    (Inverter SpikeResistant) magnet wire, which is up to 100 timesmore resistant to voltage spikes. Baldor was first touse Exxons new PolyrexEM grease, which protectsmotor bearings better, providing improved lubricationlife, greater shear stability, and superior resistance towashout, rust and corrosion.

    Industrys

    shortest lead

    times/Flexible

    manufacturing.

    Baldor has theindustrys shortest

    lead times oncustom motors just ten workingdays. Our uniqueFLEX FLOWmanufacturing process lets us produce any order in anyquantity, quickly and efficiently.

    Industrys best information. Only Baldor offerscustomers so many choices for product informationwith a wide variety of catalogs and product brochures, aCD-ROM electronic catalog, the Baldor Web site (www.baldor.com), or you may talk to a Baldor customer

    service person at one of our sales offices.

    1985

    20%

    1990 2000

    50%

    90%

    2003

    94%

    Table of Contents

    PageSpecifications and Features Design Features 3 ISR Wire / POLYREXEM Grease 5 Energy Savings 6 Design Characteristics 7

    Open Drip Proof - WPI, WPII 9 IEC Metric Frame 10 Totally Enclosed Fan Cooled 11 Inverter/Vector - Totally Enclosed Blower Cooled 13 Matched Performance Curve 14 Explosion-Proof 14

    Custom Motor Options 18

    Motor Performance Data Totally Enclosed Fan Cooled 15 Totally Enclosed Blower Cooled 17 Open Drip Proof 17 Explosion Proof 17

    Motor Dimensions 19-23

    Connection Diagrams 24-25

    Sample Test Data Report 26

    CustomerPreference

    Percentage of research studies in which

    Baldor was chosen most preferred.

  • 7/22/2019 Motor Baldor Data Sheet

    3/32www.baldor.com

    The Best Valuein Large Motors, too.

    Years ago, when Baldor began making large frame AC

    motors and drives, we spent a lot of time in the field.

    We talked in depth with plant maintenance and designengineers. We asked about tough environments such

    as mining, pulp and paper manufacturing, and chemical

    processing. We took the opportunity to learn in great

    detail what capabilities and characteristics people like

    and need. And most important, we learned what not to

    do.

    One of the frequent suggestions was the need for better

    structural integrity and rigidity. And many wanted mo-

    tors that were tough enough to withstand the rigors of

    even the most extreme applications.

    Today, Baldor makes tough, reliable motors up to 1,250HP for a wide variety of applications. And we continue

    to listen and follow through on what customers want.

    Thats why you can count on Baldor for superior value.

    Baldor large frame motors and drives feature:

    Choice of all popular enclosures,

    voltages and frequency, custom orders

    are no problem.

    Choice of Baldor Super-ENEMA Premium

    efficiency or high efficiency designs.

    Extra heavy-duty cast iron frames,

    endplates and stiff foot structures, to

    minimize potential vibration problems.

    Premium rotor system design, to operate

    below the 1st critical design speed by at

    least a 15% safety margin can be

    operated from a adjustable speed control

    through entire speed range.

    Choice of standard high-pressure

    die-cast aluminum rotors or fabricatedcopper bar rotors.

    Precision dynamic balanced with state-of-

    the-art equipment, to ensure finished

    motors meet NEMA vibration standards.

    Class H-rated vacuum pressure

    impregnated (VPI) insulation systems

    with surge rings on all end turns to

    minimize risk of premature failure.

    Electrical grade steel laminations, to

    minimize eddy currents and hysteresis

    losses, results in cooler operation and

    more efficiency.

    Upgraded low-loss electrical grade core plates,

    to reduce core losses for the life of the motor

    (others offer as low as C-3, standard).

    Ability to meet many industry standard

    specifications such as IEEE 841or

    company-specific specs.

    There are many other advantages to specifying

    Baldor large frame motors or drives. Youll find

    them on the following pages as well as all the specs

    you need to make the perfect decision

    for your application.

    Take a look. Talk to your Baldor distributor. If you dont

    see what you need, ask us about custom capabilities.

    You can likely have it on your floor in three weeks or

    less.

    A Baldor 400 Hp, 449T Open Drip Proof Motor located in the

    Dallas water pumping station.

  • 7/22/2019 Motor Baldor Data Sheet

    4/32www.baldor.com3

    Large Frame AC Motors: Built for Reliable Performance

    Class F (or better) insulation system allows

    winding to withstand higher temperatures resulting

    in longer life. Medium voltage motors feature

    formed copper coils with glass mica-wrapped

    magnet wire, further insulated with Nomex tape.

    Baldor ISR (Inverter Spike Resistant)copper

    magnet wire on low voltage motors (

  • 7/22/2019 Motor Baldor Data Sheet

    5/32www.baldor.com

    Auxiliary conduit box on medium

    voltage ratings for winding RTDs

    and space heaters. High-pressure die cast aluminum

    rotor through 449T frame; fabricated

    copper bar rotor on larger sizes

    for increased efficiency. Precision

    balanced for smooth operation and

    longer bearing life.

    Locked bearing construction

    reduces endplay. Convertible to

    roller bearing for belted loads.

    Optional sleeve bearings available.

    Operates below the first critical speed by at least

    a 15% margin - allows operation throughout entire

    speed range with adjustable speed control.

    High strength shaft steel.

    Generalized Ranges

    EnclosureFRAME SIZES

    Ref. Page449T 5000 5800

    TEFC 250-400 HP 400-600 HP 400-800 HP 6

    ODP 200-450 HP 500-800 HP 500-1250 HP 8

    WPI 500-800 HP 500-1250 HP 8

    WPII 500-800 HP 500-1250 HP 8

    Inverter/ Vector 250-350 HP 400-600 HP 400-800 HP 10

    Explosion Proof 250-300 HP 11

    Typical 4-Pole HP ranges.

  • 7/22/2019 Motor Baldor Data Sheet

    6/32www.baldor.com5

    Baldors Severe Duty motors are another example of our commitment to provide reliable

    performance, while exceeding customer expectations.

    Wound with ISR(Inverter Spike Resistant) Magnet Wire

    Recognized as Product of the Year

    by Plant Engineering magazine in

    1996, Baldors ISR wire is a standard

    feature in Baldor AC motors, 575 volt

    and under, 1 hp and up.

    Motors wound with ISR wire are up to

    100 times more resistant to transient

    voltage spikes, high frequencies

    and short rise time pulse frequently

    produced by inverters and vectordrives. The result is a better motor

    with longer life, reduced downtime

    and better overall value.

    Standard on All Baldor Motors: Exxon PolyrexEM Polyurea Grease

    Its a fact: Bearing failure is the #1 mechanical reason for motor failure. So the better the grease

    protecting those bearings, the better and longer the motor performs.

    Today, that better grease is Exxons new PolyrexEM polyurea grease now standard on all

    Baldor motors. It provides lubrication life of more than four times greater than other polyurea

    greases in tests up to 350F. It exhibits greater durability when subjected to mechanical shearing

    forces. Furthermore, a specially formulated additive in the grease resists washout, rust and

    corrosion even when subjected to salt water conditions.

    ISRWire is Superior in Pulse Endurance Test

    Going Beyond the Industry Standardin Severe Duty Motors

    1000

    100

    10

    1

    0.1

    Index

    Moisture Resistant

    MR WireTriple Build

    Wire

    ISR Wire

    Technical Specifications:NEMA MW-35

    Pulse EnduranceTest Conditions:Twisted pairs @ 20,000 Hz,

    2 kV, 0.025 microsecond

    risetime, 50% duty cycle, 90C

    Pulse Endurance Index =Life of Product/Life of 18 H

    MW-35 (Reference)

    Thermal Properties, ChemicalResistance and Dielectric

    Strength:ISR Wire is equal to or better

    than MR wire.

    Thermal Rating: 200C

    Source:Phelps Dodge Magnet Wire

    Company (Used with permission)

    Excellent Shear StabilityOutstanding High-Temperature

    Lubrication Life

    ASSTM

    D

    217

    Cone

    Pene

    tration

    (mm

    /10)

    265280295310325340355

    370385400415430

    Polyrex EM CompetitivePolyurea Grease

    Typical LithiumComplex Grease

    As illustrated here, the proprietary polyurea thickener system inPolyrex EM exhibits excellent durability and stability when subjected to

    a mechanical shearing force. Mechanical shear stability is a measurementof the greases thickener system. Good mechanical shear stability is

    important in roller bearing applications where excessive grease softeningmay lead to grease leakage or purging from the bearing.

    Source: Exxon Mobil Product Data Sheet DG-3C, 6/15/99.

    Penetration after

    60 strokes

    Penetration after

    100,000 strokes

    800

    700

    600

    500

    400

    300

    200

    100

    0ASTM

    D3336Grease

    Lifea

    t

    350F(ho

    urs

    )

    Polyrex EM CompetitivePolyureaGrease

    TypicalSynthetic

    Lithium ComplexGrease

    TypicalLithiumComplexGrease

    In the severe ASTM D 3336 High-Temperature Grease Life Test,Polyrex EM dramatically out performed a competitive polyurea

    grease and conventional lithium-complex greases.

    Source: Exxon Mobil Product Data Sheet DG-3C, 6/15/99.

  • 7/22/2019 Motor Baldor Data Sheet

    7/32www.baldor.com

    Making Energy Efficiency Work For You

    Why is Energy Efficiency Important?Electric motor-driven systems used in industrial processes consumed 679 billion kWh, or 63% of all electricity used in U.S. industrial

    sector, according to a U.S. Department of Energy report published in 1998. The report goes on to reveal that industrial motor energy

    could be reduced by up to 18 percent if companies were to apply motor and motor system efficiency upgrades, including the use ofadjustable speed drives. The potential positive impacts on companies bottom lines and the environment are significant.

    Purchase Price is Onlya Small Piece of the Pie

    The pie chart to the right shows the typical life cycle cost of a 100 hp

    motor operating in continuous duty over a 20-year life. As you can see,

    the original purchase price is almost insignificant compared to what it

    will cost to power the motor during its useful life.

    How Baldor Super-E

    Efficiencies Compare toIndustry StandardsBaldors line of Super-E motors offers customers the

    highest level of overall efficiencies available from any

    motor manufacturer, complying with NEMA Premium

    efficiency.

    BE$T Baldor Energy SavingsToolMakes CalculatingPayback Easy

    In order to make payback calculations easier forcustomers, Baldor developed BE$T (Baldor Energy

    Savings Tool). BE$T helps calculate energy cost

    and energy savings for motors, as well as payback

    timeframes. A popular feature of BE$T is that it

    allows users to make head-to-head comparisons of

    up to three motors, giving customers the information

    to make an informed decision through comparative

    analysis.

    BE$T Baldor Energy Savings Tool is available as a

    download through Baldors award-winning Web site(www.baldor.com/support/index.asp,) as well

    as a stand-alone CD-Rom available from the

    Baldor Literature Hotline (1-800-828-4920).

    Initial

    Purchase 2%

    One

    Rewind 0.7%

    Energy

    97.3%

    1 1.5 2 3 5 8 10 15 20 25 30 40 50 60 75 100 125 200

    Horsepower

    Baldor

    Super-E

    EPAct

    efficiencies

    Average

    efficiency of

    motors in use

    70

    85

    100%

    Power Cost Per kWH

    168

    Hour Week

    Continuous

    80 Hour

    Week

    2 Shifts

    40 Hour

    Week

    1 Shift

    Do

    llar

    Sa

    vings

    Per

    Year

    Savings based ona 40 hp, BaldorSuper-E 94.5%compared with theaverage efficiencyof motors in use.(50 weeks/year)

    .05 .06 .07 .08 .09 .100

    300

    600

    900

    1200

    $1500

    Electric Motor Efficiency Ratings

    What is Higher Efficiency Worth?

  • 7/22/2019 Motor Baldor Data Sheet

    8/32www.baldor.com7

    Electrical Design Characteristics

    Specification DescriptionLow

    VoltageMediumVoltage

    Voltage 460 or 575 volts, random-wound S

    950 volts, random-wound O

    2300, 3300, 4160 or 2300/4160 volts, formed-coil S

    460, 950 or 6600 volts, formed-coil O

    Frequency 60 Hz standard, 50 Hz optional S S

    Service Factor 1.15 standard S S

    Ratings NEMA Design B S S

    NEMA Design C (contact Baldor for frame size) O O

    NEMA Design D (contact Baldor for frame size), 1.0 S.F. O O

    Crusher Duty (high pull-out, pull-up and locked rotor torques) O O

    Duty Cycle Continuous Duty S S

    Special Duty Cycles O O

    Ambient Temperature 40oC ambient temperature S S

    Higher or lower ambient temperatures O OTemperature Rise Class B rise (80oC) at 1.0 service factor, Class F rise at 1.15SF S S

    Laminations Low-loss electrical grade steel S S

    Windings Class H+ (200oC) ISR (Inverter Spike Resistant)copper magnet wire S

    Class H+ (200oC) Copper form-wound coils wound with micatape and VPI epoxy impregnated

    S

    Insulation Class Class F, Non-hygroscopic epoxy VPI S S

    Class H, Non-hygroscopic epoxy VPI O O

    End Turn Bracing Surge rings laced to end-turns and VPI epoxy impregnatedfor structural integrity

    S S

    Stator Insulation Nomex Class H slot liner S S

    Woven Class H glass phase insulation S

    Epoxy impregnated blocking felt between coils S

    Lead Material Non-wicking cross-linked polyethylene material S S

    Thermal Protection Thermostats S O

    RTDs with separate conduit box 100 platinum standard,10 copper or 120 nickel optional; (RTDs standard in stock

    TEFC and ODP motors 300 Hp and up)O O

    Thermistors O O

    Space Heaters 120 volt standard, other voltages optional

    (Strip space heaters standard in stock TEFC motors 300 Hp and up) O O

    Feedback Devices 1024 PPR Electrically isolated BEI optical encoder standard onBaldor Vector Drivemotors (other PPR available)

    O O

    NorthStar(LakeShore) or Avtron pulse generators available O O

    Resolvers available O O

    Testing Standard test supplied with motor (Balance test, winding resistance,no-load, full load, amps and speed, power factor, torqueand hi-pot test per NEMA MG-1)

    S S

    Heat run and complete efficiency testing at temperature O O

    Either of above tests as witnessed O O

    Approvals CSA recognized components through 449T (File LR2262)5000 and 5800 TEFC frame through 600 HP and up to 600 volts;500 HP and up to 4160 volts (File LR36841)

    S S

    S = Standard O = Optional

  • 7/22/2019 Motor Baldor Data Sheet

    9/32www.baldor.com

    Mechanical Design Characteristics

    Specification Description Low VoltageMedium

    Voltage

    Frame Dimensions NEMA S S

    IEC Metric O O

    Construction Complete cast iron frame, endplates, conduit box and fan cover(5800 frame has steel fan cover) S S

    Multiple Mounting

    Holes in Base

    Multiple mounting holes standard.

    Dowel pin holes standard on all 5000 and 5800 frames.S S

    Face mounting C-face, D-flange, P-base available O O

    Custom mounting configurations available O O

    Nameplate Stainless steel, Complete operating data in accordance

    with NEMA MG-1. Bearing identification numbers includedS S

    Conduit Box Oversized cast iron, diagonally split box, rotatable in 90o increments.

    Gasketed lid and gaskets between frame and box. NPT threaded

    opening. F-1 orientation standard, convertible to F-2 (top-mount

    conversion available on 5800 frame)

    S S

    Extra-large oversized conduit boxes available O O

    Slinger & Seals ForshedaV-type neoprene slinger each (Chemical Process motors only) S S

    Inpro sealon shaft O O

    Drains One-way drain and breather located at lowest point of motor when

    mounted in a horizontal positionO O

    Hardware Grade 5, U.S. Standard, zinc dichromate or cadmium-plated steel S S

    Stainless steel hardware O O

    Ground Lug Located in conduit box. Silicon-bronze stud-type. S S

    Lifting Provisions Integrally-cast lifting lugs motor can be lifted with any enclosure in tact S S

    Enclosure TEFC, Open Drip-proof, WPI, WPII, TEBC, TEWAAC

    Cooling Fan TEFC & TEBC Non-sparking S S

    Non-sparking metal O O

    Rotor Construction High pressure die-cast aluminum (through 449) S S

    Fabricated copper bar construction (5000 up) S S

    Balance Dynamically balanced better than NEMA MG1 specs S SShaft Material 1045 high strength steel (through 5000 frame) S S

    4140 high strength steel (5800 frame - up) S S

    Other high strength alloys or forged shafts O O

    Paint Grey lacquer over primer coat S S

    Two-part epoxy system with 4-6 mils build (Chemical Process motors) S S

    Customer specified paint O O

    Bearings Premium grade vacuum-degassed ball bearings S S

    Roller bearing on drive end O O

    Renk sleeve bearings (5000-up) O O

    Electrically isolated bearings O O

    Bearing temperature RTDs O O

    Vibration monitors O O

    Lubrication Exxon PloyrexEM grease (or equivalent) S S

    Oil lube for sleeve bearings S S

    Customer specified grease O O

    Oil mist lubrication O O

    Grease Provisions NPT fittings installed in endplate with pressure relief fittings on drain lines S S

    Oil sight gauges for sleeve bearings S S

    Engineering

    Specifications

    IEEE 841- 2001 O O

    Customer specific requirements O O

    Limited Warranty 3 years on Super-E, 24 months on Standard-E,

    18 months most other motorsS S

    S = Standard O = Optional

  • 7/22/2019 Motor Baldor Data Sheet

    10/32www.baldor.com9

    Open Drip Proof andWPI WPII

    Baldor Electric offers a rugged cast iron industrial motor in your

    choice of open enclosures. Standard motor designs

    are high efficiency, but our Super-Ewith NEMA Premiumefficiency is also available.

    460, 575, 950, 2300, 3300, 4160 or 6600 volts 60 Hz

    380, 400, 415, 950, 2300, 4160 or 6000 volts 50 Hz

    High efficiency or Super-ENEMA Premium efficiency

    Class B rise with Class F insulation

    Baldor ISR (Inverter Spike Resistant)magnet wire on designs

    below 600 volts

    ODP High Efficiency 460 or 575 volts, 60 Hz, 1.15 SF

    HP kW RPM3600 1800 1200 900

    200 150 444TS 445T 445T 5007L

    250 187 445TS 445T 449T 5009L

    300 224 445TS 445T 449T 5009L

    350 261 445TS 445T 5009L 5009L

    400 298 449TS 449T 5009L 5011L

    450 336 449TS/5009S 449T 5009L 5011L

    500 373 5009S 5009L 5011L 5808

    600 448 5009S 5009L 5011L 5810

    700 522 5009S 5011L 5808 5810

    800 600 5808S 5011L 5810

    900 671 5808S 5808 5812 1000 746 5808S 5810

    1250 933 5810 444TS, 445TS, 445T motors do not have standard VPI. 5000 & 5800 frame motors can be ODP or WPI.

    ODP WPI High Efficiency 2300 or 4160 volts, 60 Hz, 1.15 SF

    HP kWRPM

    3600 1800 1200 900

    150 112 449TS 449T 449T 5009L

    200 150 449TS 449T 5009L 5009L

    250 187 449TS 449T 5009L 5009L

    300 224 449TS 449T/5009L 5009L 5011L

    350 261 5009S 5009L 5009L 5011L400 298 5009S 5009L 5011L 5808

    450 336 5009S 5009L 5011L 5808

    500 373 5009S 5009L 5011L 5810

    600 448 5009S 5011L 5808 5810

    700 522 5009S 5011L 5810 5812

    800 600 5808S 5808 5812

    900 671 5808S 5810

    1000 746 5810

    1250 933 5810

    Data subject to change without notice. 5000 & 5800 frame motors can be ODP or WPI.Contact a Baldor office for latest capabilities.

  • 7/22/2019 Motor Baldor Data Sheet

    11/32www.baldor.com

    IEC Metric Frames Available

    In addition to the NEMA frames show here, Baldor motors

    are available with IEC metric mounting dimensions in

    frames through 450. Contact Baldor for dimensions and

    layout drawings.

    ODP/WPI High Efficiency 6600 volts, 60 Hz, 1.15 SF

    HP kWRPM

    3600 1800 1200 900

    350 261 5808S 5009L 5009L 5011L

    400 298 5808S 5009L 5009L 5808

    450 336 5808S 5009L 5011L 5810

    500 373 5808S 5009L 5808 5810600 448 5808S 5011L 5810

    700 522 5808S 5808

    WPII High Efficiency 460 or 575 volts, 60 Hz, 1.15 SF

    HP kWRPM

    3600 1800 1200 900

    300 224 5009S 5009L 5009L 5009L

    350 261 5009S 5009L 5009L 5009L

    400 298 5009S 5009L 5009L 5011L

    450 336 5009S 5009L 5011L 5011L/5808

    500 373 5009S 5009L 5011L 5808

    600 448 5009S 5011L 5011L 5810700 522 5009S*/5808S 5011L 5808 5810

    800 600 5808S 5011L 5810

    900 671 5808S 5810 5812

    1000 746 5810

    1250 933 5810

    WPII High Efficiency 2300 or 4160 volts, 60 Hz, 1.15 SF

    HP kWRPM

    3600 1800 1200 900

    300 224 5009S 5009L 5009L 5009L

    350 261 5009S 5009L 5009L 5009L

    400 298 5009S 5009L 5011L 5808

    450 336 5009S 5009L 5011L 5808

    500 373 5009S 5009L 5011L 5810

    600 448 5009S 5011L 5808 5812

    700 522 5009S/5808S 5011L 5810

    800 600 5009S*/5808S 5808 5810

    900 671 5808S 5810 5812

    1000 746 5810

    1250 933 5810

    Data subject to change without notice. Contact a Baldor office for latest capabilities.

  • 7/22/2019 Motor Baldor Data Sheet

    12/32www.baldor.com1

    TEFC Totally EnclosedFan Cooled

    Baldor Electric offers the ultimate rugged

    cast iron industrial motor for your most severe

    process applications. Motor designs areSuper-Epremium efficiency, but high

    efficiency is also available.

    460, 575, 950, 2300, 3300, 4160 or

    6600 volts 60 Hz

    380, 400, 415, 950, 2300, 4160 or

    6000 volts 50 Hz

    Super-Epremium or high efficiency

    Class B rise with Class F insulation

    Baldor ISR (Inverter Spike Resistant)

    magnet wire on designs below 600 volts

    TEFC Super-ENEMA PremiumEfficiency460 or 575 Volts, 60 Hz, 1.15 SF

    HP kWRPM

    3600 1800 1200 900

    200 150 447TS 447T 449T 5007L

    250 187 449TS 449T 449TY 5009L/5810

    300 224 449TS 449TY/449TSY 449TY 5011LY/5810

    350 261 449TS 449TY/449TSY 5009L/5810 5011LY/5810

    400 298 449TS449TY/449TSY

    5007L/58105011LY/5810 5810

    450 336 5007SY 5007L/5810 5011LY/5810 5810

    500 373 5009SY 5009L/5810 5011LY/5810 5812

    600 448 5009SY 5011LY/5810 5810 5812

    700 522 5810 5810

    800 600 5810

    900 671 5812

    Sleeve bearings required.Data subject to change without notice.

    Contact a Baldor office for latest capabilities.

  • 7/22/2019 Motor Baldor Data Sheet

    13/32www.baldor.com

    TEFC Super-ENEMA PremiumEfficiency2300 or 4160 Volts, 60 Hz, 1.15 SF

    HP kWRPM

    3600 1800 1200 900

    100 74.6 449T

    125 93.2 449T

    150 112 447TS 449T 449T 5007L

    200 150 449TS 449T 449T/5007L 5009L

    250 187 449TS/5007SY 449T/5007L 5007L/5009L 5011LY/5810

    300 224 5007SY 449TY/5007L/5011LY 5009L/5011LY/5810 5011LY/5810

    350 261 5007SY 5007L/5011LY 5009L/5011LY/5810 5810

    400 298 5007SY 5007L/5011LY/5810 5011LY/5810 5810

    450 336 5007SY 5007L/5011LY/5810 5011LY/5810 5810

    500 373 5009SY 5009L/5011LY/5810 5011LY/5810 5812

    600 448 5011LY/5810 5810

    700 522 5810 5812

    800 600 5812

    TEFC Super-ENEMA PremiumEfficiency6600 Volts, 60 Hz, 1.15 SF

    HP kWRPM

    3600 1800 1200 900

    150 112 5007SY 5007L 5007L 5009L

    200 150 5007SY 5007L 5007L 5011LY

    250 187 5007SY 5007L 5009L 5011LY 300 224 5009SY 5007L 5011LY 5810

    350 261 5009SY 5007L 5011LY 5810

    400 298 5009SY 5009L 5011LY 5810

    450 336 5009SY 5011LY 5810

    500 373 5011LY 5810

    600 448 5810

    Sleeve bearings required.Data subject to change without notice.

    Contact a Baldor office for latest capabilities.

  • 7/22/2019 Motor Baldor Data Sheet

    14/32www.baldor.com3

    Inverter / Vector Duty -TEBC Totally Enclosed Blower Cooled

    Baldor Electric offers the ultimate rugged cast iron industrial motor

    for your adjustable speed, constant torque applications. Motors are Super-E

    NEMA Premiumefficiency.

    460 or 575 or 6600 volts 60 Hz

    380, 400 or 415, or 6000 volts 50 Hz

    Super-ENEMA Premium efficiency

    Able to start across line without drive

    Class F rise with Class H insulation

    Baldor ISR (Inverter Spike Resistant)

    magnet wire on designs below 600 volts

    Separately powered heavy duty axial

    cooling fan Electrically isolated BEI optical encoder

    on vector drive motors optional Avtron or

    NorthStar pulse generators

    Shaft grounding assembly

    Option formed coil winding on 460 or 575 V.

    Inverter/Vector 460 or 575 Volts, 60 Hz, 1.0 SF

    HP kW RPM3600 1800 1200 900

    200 150 447TS 447T 449T 5007L

    250 187 449TS 449T 449T 5009L/5810

    300 224 449TS 449T 449T 5011LY/5810

    350 261 449TS 449T 5009L/5810 5011LY/5810

    400 298 449TS 5007L/5810 5011LY/5810 5810

    450 336 5007S 5007L/5810 5011LY/5810 5810

    500 373 5009S 5009L/5810 5011LY/5810 5810

    600 448 5009S 5011LY/5810 5810

    700 522 5810 5810

    800 600 5810 Sleeve bearings required.Data subject to change without notice.

    Contact a Baldor office for latest capabilities.

  • 7/22/2019 Motor Baldor Data Sheet

    15/32www.baldor.com

    Matched Performance Curves

    Matched Performance is Baldors

    solution to the concern, What kind of constant

    horsepower speed range will I get with this

    combination of motor and control? Each

    test is performed in Baldors ownengineering laboratory.

    These performance curves show the

    continuous operating constant torque speed

    range that can be produced without exceeding

    Class F temperature rise in the motor. Peak

    torque is the maximum amount of torque a

    Baldor inverter or vector drive can produce.

    This may be limited by either the motors

    breakdown torque or the current from

    the control.

    0 300 600 900 1200 1500 1800 21000.0

    150.0

    300.0

    450.0

    600.0

    750.0

    900.0

    1050.0

    1200.0

    0.00

    50.00

    100.00

    150.00

    200.00

    250.00

    300.00

    350.00

    400.00

    450.00

    TORQUE

    AMPS

    TORQUE(ft-lbs)

    SPEED (rpm)

    HORSEPOWERAM

    PS

    1350.0PEAK TORQUE

    HORSEPOWER

    CONTINUOUSOPERATING AREA

    Explosion Proof Motors

    Baldor Electric offers the ultimate rugged cast

    iron industrial motor for applications where

    hazardous fumes or dust may be present.

    460, or 575 60 Hz

    380, 400, or 415 volts 50 Hz Super-ENEMA Premiumefficiency or high efficiency

    Class B rise with Class F insulation

    Baldor ISR (Inverter Spike Resistant)magnet wire

    UL and CSA approved for hazardous locations

    Includes UL approved conduit box

    Explosion Proof Motors 460 or 575 volts, 60 Hz, 1.0 SF

    HP kWRPM

    3600 1800 1200 900150 112 445TS 445T 449T 449T

    200 150 449TS 449T 449T

    250 187 449TS 449T 449T

    300 224 449TS 449T

    Class I, Group C & D; Class II, Groups F and G, T3CData subject to change without notice.

    Contact a Baldor office for latest capabilities.

  • 7/22/2019 Motor Baldor Data Sheet

    16/32www.baldor.com5

    Performance DataTEFC NEMA PremiumEfficiency 460 Volts, 3 Phase, 60 Hz, 1.15 SF

    AMPS @ 460V RATEDTORQUE

    LB. FT.

    EFFICIENCY %POWER FACTOR

    %BEARINGS

    HP kW RPM FRAME CATALOG #

    FULL

    LOAD

    LOCKED

    ROTOR 1/2 3/4

    FULL

    LOAD 1/2 3/4

    FULL

    LOAD D.E. O.D.E.

    200 149

    3570 447TS ECP4416T-4 214 1720 294 94.4 95.2 95.4 87 91 92 6314 6314

    1780 447TS ECP4407T-4 225 1530 589 95.0 96.0 96.2 82 86 87 6319 6314

    1180 449T ECP44206T-4 242 1647 890 94.5 95.2 95.8 70 80 81 6319 6314

    890 5007L Custom 238 1342 1180 93.7 94.4 95.0 76 81 82 6324 6222

    250 187

    3545 449TS ECP44252T-4 272 2162 370 95.4 95.8 95.8 81 87 90 6314 6314

    1780 449T ECP4408T-4 281 1910 740 95.2 95.8 96.2 82 85 87 6319 6314

    1180 449TY ECP44256T-4 294 1690 1105 95.0 95.6 95.8 73 80 83 6319 6314

    890 5009L Custom 298 1775 1475 94.6 95.2 95.4 72 79 82 6324 6222

    300 224

    3545 449TS ECP44302T-4 320 2546 444 95.3 95.5 95.8 86 90 91 6314 6314

    1785 449TY ECP44304T-4 337 2290 883 95.2 96.0 96.2 81 86 87 6319 6314

    1185 449TY ECP44306T-4 355 2370 1328 94.3 95.0 95.0 71 80 83 6319 6314

    1185 5007L Custom 344 2592 1765 95.2 95.6 95.8 80 84 86 6322 6222

    350 261

    3545 449TS ECP44352T-4 344 2930 518 95.3 96.0 96.2 88 91 92 6314 6314

    1785 449TY ECP44354T-4 393 2670 1032 95.0 95.8 95.8 81 86 87 6319 6314

    1185 5009L Custom 400 1880 1551 95.5 95.8 95.8 79 82 84 6322 6222

    895 5810 Custom 422 2574 2054 94.0 94.5 94.5 68 77 81

    400 298

    3545 449TS ECP44402T-4 422 3155 592 95.4 95.8 95.8 89 92 93 6314 6314

    1780 449TY ECP44404T-4 454 3151 1179 95.6 95.8 96.2 78 82 87 6319 6314

    1190 5011L Custom 446 3025 1765 95.9 96.3 96.0 82 87 88 6322 6222

    890 5810 Custom 2358

    450 336

    3570 5009S Custom 482 2917 660 95.8 96.2 96.2 86 90 91 6314 6314

    1790 50011LY Custom 498 3315 1320 95.4 95.8 96.2 80 84 88 6322 6222

    1185 5011L Custom 486 3757 1995 94.9 95.7 95.8 78 86 87 6322 6222

    890 5810 Custom 2654

    500 373

    3575 5009S Custom 530 3389 735 96.2 96.4 96.2 89 92 92 6314 6314

    1785 5011L Custom 540 3487 1465 95.6 96.1 96.5 84 88 90 6322 6222

    1185 5011L Custom 552 3822 2216 96.0 96.2 96.2 82 87 89 6322 6222

    890 5810* Custom 2950 6324 6322

    600 448

    3575 5009S Custom 636 4464 881 95.8 96.0 96.2 89 91 92 6314 6314

    1790 5011L Custom 638 3803 1758 96.2 96.8 97.0 88 91 91 6322 6222

    1185 5810 Custom 2658 6324 6322

    700 522

    3585 5009S Custom 1025 6314 6314

    1785 5810 Custom 2058 6322 6322

    1185 5810* Custom 3101 6324 6322

    800 600 1785 5810* Custom 2353 6324 6322

    *1.0 SFIf data is not shown, contact a Baldor office.Data subject to change without notice.

    Contact a Baldor office for latest capabilities.

  • 7/22/2019 Motor Baldor Data Sheet

    17/32www.baldor.com

    TEFC NEMA PremiumEfficiency 460 Volts, 60 Hz, 1.15 SF with Roller Bearings AMPS @ 460V RATED

    TORQUELB. FT.

    EFFICIENCY % POWER FACTOR % BEARINGS

    HP kW RPM FRAME CATALOG #FULL

    LOAD

    LOCKED

    ROTOR

    1/2 3/4FULL

    LOAD

    1/2 3/4FULL

    LOAD

    D.E. O.D.E.

    150 112 1180 447TY ECP44156TR-4 178 1154 667 95.2 95.8 95.8 49 79 82 NU319 6314

    200 1491780 447TY ECP4407TR-4 225 1530 589 95.0 96.0 96.2 82 86 87 NU319 6314

    1180 449TY ECP44206TR-4 242 1647 890 94.5 95.2 95.8 70 80 81 NU319 6314

    250 1871780 449TY ECP4408TR-4 281 1910 740 95.0 96.0 96.2 81 86 87 NU319 6314

    1180 449TY ECP44256TR-4 294 1690 1105 95.0 95.6 95.8 73 80 83 NU319 6314

    300 224

    1785 449TY ECP44304TR-4 337 2290 883 95.2 96.0 96.2 81 86 87 NU319 6314

    1185 449TY Custom 355 2370 1328 94.3 95.0 95.0 71 80 83 NU319 6314

    1185 5007L Custom 344 2592 95.2 95.6 95.8 80 84 86

    350 261 1785 449TY ECP44354TR-4 393 2670 1032 95.0 95.8 96.2 81 86 87 NU319 6314

    400 298 1780 449TY ECP44404TR-4 449 3050 1179 95.2 96.0 96.2 81 86 87 NU319 6314

    TEFC High Efficiency 460 Volts, 3 Phase, 60 Hz, 1.15 SF

    AMPS @ 460V RATEDTORQUELB. FT.

    EFFICIENCY % POWER FACTOR % BEARINGS

    HP kW RPM FRAME CATALOG #FULLLOAD

    LOCKEDROTOR

    1/2 3/4FULLLOAD

    1/2 3/4FULLLOAD

    D.E. O.D.E.

    200 149 1180 449T M44206T-4 236 1337 885 94.8 95.3 95.0 64 76 81 6314 6319

    300 224 1785 449T M44304T-4 328 2566 883 95.8 96.0 95.8 81 86 88 6314 6319

    350 261 1785 449T M44354T-4 388 2871 1032 94.5 95.7 95.8 81 88 89 6314 6319

    400 298 1785 449T Custom 440 3134 1180 95.8 96.1 95.8 82 88 89 6314 6319If data is not shown, contact a Baldor office.Data subject to change without notice.

    Contact a Baldor office for latest capabilities.

    Performance Data

  • 7/22/2019 Motor Baldor Data Sheet

    18/32www.baldor.com7

    TEFC NEMA PremiumEfficiency 575 Volts, 60 Hz, 1.15 SFAMPS @ 575V RATED

    TORQUELB. FT.

    EFFICIENCY % POWER FACTOR % BEARINGS

    HP kW RPM FRAME CATALOG #FULLLOAD

    LOCKEDROTOR

    1/2 3/4FULLLOAD

    1/2 3/4FULLLOAD

    D.E. O.D.E.

    200 149

    3570 447TS 174 294 94.8 95.4 95.8 83 87 89 6314 6314

    1780 447T ECP4407T-5 179 1602 589 95.2 95.8 96.2 80 84 87 6319 6314

    1180 449T Custom 194 1341 890 94.4 95.1 95.8 75 78 81 6319 6314

    890 5007L Custom 196 1175 1180 94.6 95.2 95.0 70 78 81 6324 6222

    250 187

    3545 449TS Custom 370 6314 6314

    1780 449T Custom 249 1986 740 95.0 95.6 96.2 81 83 86 6319 6314

    1180 449TY Custom 235 1105 95.8 83 6319 6314

    890 5009L Custom 242 1390 1475 94.1 94.8 95.4 79 81 82 6324 6222

    300 224

    3545 449TS Custom 444 6314 6314

    1785 449TY Custom 319 2366 833 95.0 95.8 96.2 80 84 87 6319 6314

    1185 449TY Custom 1328 6319 6314

    890 5011L Custom 290 1716 1765 94.8 95.2 95.4 77 80 82 6322 6222

    350 261

    3545 449TS Custom 518 6314 6314

    1785 449TY Custom 389 2773 1032 95.2 95.9 96.2 82 83 86 6319 6314

    1185 5009L Custom 308 2204 1551 95.1 95.5 95.8 83 87 88 6322 6222

    895 5810 Custom 2054

    400 298

    3545 449TS Custom 592 6314 6314

    1780 449TY Custom 460 3162 1179 95.0 95.8 96.2 81 84 86 6319 6314

    1190 5011L Custom 1765 6322 6222

    890 5810 Custom 2358 6324 6322

    450 336

    3570 5009S Custom 660 6314 6314

    1790 5009L Custom 1320 6322 6222

    1185 5011L Custom 1995 6322 6222890 5810 Custom 2654 6324 6322

    500 373

    3575 5009S Custom 422 2622 735 95.5 96.0 96.2 88 91 92 6314 6314

    1785 5011L Custom 1465 6322 6222

    1185 5011L Custom 438 3026 2216 96.2 96.4 96.2 82 87.5 89 6322 6222

    890 5810* Custom 2930 6324 6322

    600 448

    3575 5009S Custom 881 6314 6314

    1790 5011L Custom 510 3760 1758 96.0 96.2 96.2 91.5 92.7 93.1 6322 6222

    1185 5810 Custom 532 3380 2641 95.8 96.1 96.2 80 83 87 6324 6322

    700 522

    3585 5009S Custom 1025 6314 6314

    1785 5810 Custom 2058 6322 6322

    1185 5810* Custom 3101 6324 6322

    800 600 1785 5810* Custom 2353 6324 6322

    *1.0 SFData subject to change without notice.

    If data is not shown, contact a Baldor officeContact a Baldor office for latest capabilities

    Performance Data

  • 7/22/2019 Motor Baldor Data Sheet

    19/32www.baldor.com

    TEFC NEMA PremiumEfficiency 2300 or 4160 Volts, 60 Hz, 1.15 SF

    AMPS @4160V RATED

    TORQUE

    LB. FT.

    EFFICIENCY % POWER FACTOR % BEARINGS

    HP kW RPM FRAME CATALOG # FULLLOAD LOCKEDROTOR 1/2 3/4 FULLLOAD 1/2 3/4 FULLLOAD D.E. O.D.E.

    200 149

    3570 447TS Custom 25 159 294 93.1 94.1 94.1 82 89 92 6314 6314

    1780 5007L Custom 25 152 589 94.0 94.5 94.1 85 89 89 6319 6314

    1185 5009L Custom 27 174 890 94.4 94.8 94.5 81 85 85 6319 6314

    890 50011L Custom 29 150 1180 93.5 93.9 93.6 73 77 77 6322 6222

    250 187

    3570 5007SY ECP50252S-2341 31 216 367 94.4 95.1 95.0 86 90 91 6314 6314

    1790 5007L ECP50254L-2341 31 214 734 92.7 94.5 95.0 81 87 89 6322 6222

    1185 5009L ECP50256L-2341 30 380 1104 93.8 94.6 95.0 78 83 85 6324 6222

    890 5011LY Custom 36 194 1475 92.9 93.8 94.1 69 74 77 6322 6222

    300 224

    3570 5007SY ECP50302S-2341 36 260 440 94.7 95.3 95.4 88 91 92 6314 6314

    1790 5009L ECP50304L-2341 37 239 880 93.4 94.9 95.4 83 88 90 6322 6222

    1185 5011LY ECP50306L-2341 40 505 1104 93.9 94.5 95.0 78 82 86 6324 6222

    890 5011LY Custom 43 239 1770 93.4 94.7 94.5 55 67 75 6322 6222

    350 261

    3570 5007SY Custom 42 292 518 95.1 95.3 95.4 86 90 91 6314 6314

    1790 5011LY ECP50354L-2341 43 285 1111 94.3 95.1 95.4 83 88 89 6322 6222

    1185 5011LY ECP50356L-2341 46 300 1545 93.9 94.6 95.0 75 83 85 6324 6222

    890 5810 Custom 47 293 2065 94.2 95.1 95.0 74 80 83 6326 6322

    400 298

    3570 5007SY ECP50402S-2341 48 332 587 94.8 95.5 95.4 86 91 91 6314 6314

    1790 5011LY ECP50404L-2341 50 323 1174 93.8 95.0 95.4 82 87 89 6322 6222

    1185 5011LY ECP50406L-2341 52 349 1765 93.9 94.8 95.0 74 82 86 6324 6222

    890 5810 Custom 54 351 2360 94.0 95.1 95.0 73 80 82

    450 336

    3580 5007SY Custom 55 558 660 95.0 95.6 95.4 88 90 92 6314 6314

    1790 5011LY ECP50454L-2341 56 364 1320 94.4 95.2 95.4 83 88 89 6322 62221190 5011LY ECP50456L-2341 68 283 1985 93.7 95.0 95.4 60 70 75 6324 6222

    890 5810 Custom 2654

    500 373

    3570 5009SY ECP50502S-2341 60 401 734 95.4 96.0 95.8 87 90 92 6314 6314

    1790 5011LY ECP50504L-2341 60 386 1467 96.1 96.2 95.8 85 89 90 6322 6222

    1190 5011LY ECP50506L-2341 72 314 2204 93.9 95.2 95.4 59 69 75 6324 6222

    890 5810* Custom 2950

    600 448

    3570 5009SY* Custom 72 379 883 95.8 95.9 95.6 92 91 91 6314 6314

    1790 5011LY Custom 73 458 1760 94.1 95.1 95.4 88 90 90 6322 6222

    1185 5810 Custom 74 509 2645 94.6 95.5 96.2 80 85 89 6324 6322

    700 5221785 5810 Custom 96 584 2343 93.9 94.8 95.4 91 92 92 6322 6322

    1185 5810* Custom 96 585 3081 95.1 95.8 95.9 71 75 79 6324 6322

    800 600 1785 5810* Custom 174 577 2343 95.0 95.2 95.4 90 91 92 6322 6322

    *1.0 SFData subject to change without notice.

    If data is not shown, contact a Baldor office.Contact a Baldor office for latest capabilities.

    Performance Data

  • 7/22/2019 Motor Baldor Data Sheet

    20/32www.baldor.com9

    Performance Data

    TEBC Vector Drive Motors 460 Volts, 60 Hz, 1.0 SF

    AMPS @ 460V RATEDTORQUELB. FT.

    EFFICIENCY %POWER FACTOR

    %BEARINGS

    HP kW RPM FRAME CATALOG #

    FULL

    LOAD

    LOCKED

    ROTOR 1/2 3/4

    FULL

    LOAD 1/2 3/4

    FULL

    LOAD D.E. O.D.E.

    MAX

    Speed250 187 1780 449TC Custom 276 1720 740 93.9 94.9 95.8 79 86 89 6314 6319 2400

    300 224 1785 449TC Custom 333 2500 883 95.1 95.8 95.8 81 86 88 6314 6319 2400

    350 261 1785 449TC Custom 388 2750 1032 95.3 95.6 95.8 83 87 89 6314 6319 2400

    400 298 1785 5007L Custom 432 2766 1172 95.5 96.2 96.2 85 89 91 6222 6322 1800

    450 336 1790 5007L Custom 492 3075 1320 95.3 96.3 96.5 85 89 91 6222 6322 1800

    500 373 1790 5009L Custom 540 3487 1465 95.1 95.9 96.8 84 88 90 6222 6322 1800

    ODP High Efficiency 460 Volts, 60 Hz, 1.15 SF

    AMPS @ 460V RATEDTORQUELB. FT.

    EFFICIENCY %POWER FACTOR

    %BEARINGS

    HP kW RPM FRAME CATALOG #FULL

    LOAD

    LOCKED

    ROTOR

    1/2 3/4FULL

    LOAD

    1/2 3/4FULL

    LOAD

    D.E. O.D.E.

    400 298 3550 449TS M25402T-4 440 2544 591 94.8 94.5 93.6 85 89 91 6314 6314

    400 298 1780 449T M25404T-4 448 3110 1179 94.4 94.7 94.5 79 86 87 6321 6314

    450 336 3550 449TS M25452T-4 488 2900 663 95.2 95.0 94.1 85 89 91 6314 6314

    450 336 1780 449T M25454T-4 506 3200 1327 95.2 95.1 94.5 80 86 88 6321 6314

    500 373 3550 5009S Custom 532 3459 732 95.4 96 95.8 82 88 90 6217 6217

    500 373 1780 5009L Custom 582 3381 1467 95.2 95.5 95.8 80 82 85 6222 6222

    600 448 3550 5009S Custom 652 4068 882 95.1 95.9 95.8 87 89 90 6217 6217

    600 448 1780 5009L Custom 658 3476 1760 96.2 96.4 96.2 87 90 90 6222 6222

    ODP/WPI High Efficiency, 2300/4160 V, 60 Hz, 1.15 SF

    AMPS @ 460VRATEDTORQUELB. FT.

    EFFICIENCY %POWER FACTOR

    %BEARINGS

    HP kW RPM FRAME CATALOG #FULLLOAD

    LOCKEDROTOR

    1/2 3/4FULLLOAD

    1/2 3/4FULLLOAD

    D.E. O.D.E.

    300 224 3560 449T Custom 37 240 442 92.7 93.8 94.1 85 89 92 6314 6314

    300 224 1785 5009L Custom 38 224 883 94.1 94.6 94.5 82 87 89 6222 6222

    400 298 3580 5009S Custom 49 557 587 94 94.8 95 84 88 90 6217 6217

    400 298 1790 5009L Custom 52 329 1174 93.3 95.1 95 81 86 86 6222 6222

    500 373 3580 5009S Custom 61 401 735 95.2 95.6 95.4 85 88 90 6217 6217

    500 373 1790 5009L Custom 64 427 1468 93.7 94.5 95 82 85 87 6222 6222

    600 448 3580 5009S Custom 72 462 881 94.7 95.5 95.8 84 88 90 6217 6217

    600 448 1790 5009L Custom 76 416 1763 93.7 94.8 95.4 80 85 88 6222 6222

    TEFC Explosion Proof 460 Volts, 60 Hz, 1.15 SF

    AMPS @ 460V RATEDTORQUELB. FT.

    EFFICIENCY %POWER FACTOR

    %BEARINGS

    HP kW RPM FRAME CATALOG #FULLLOAD

    LOCKEDROTOR

    1/2 3/4FULLLOAD

    1/2 3/4FULLLOAD

    D.E. O.D.E.

    200 150 1785 447T M74204T-4 218 1448 588 95.0 95.5 95.4 80 88 90 6319 6314

    250 187 1785 449T M74254T-4 272 1774 736 94.8 95.6 95.4 79 87 90 6319 6314

    300 224 1785 449TY M74304T-4 328 2241 883 95.1 95.8 95.8 80 88 90 6319 6314

    If data is not shown, contact a Baldor office.Data subject to change without notice.

    Contact a Baldor office for latest capabilities.

  • 7/22/2019 Motor Baldor Data Sheet

    21/32www.baldor.com

    Common Custom Motor Options

    Electrical

    Bearing RTDs Winding RTDs , Thermistors or Thermostats

    Special Design C or D Windings

    Fabricated Copper Bar Rotors (5000 frame and up)

    Complete Electrical Tests, Heat Runs and

    Assorted Tests (Witnessed and Unwitnessed)

    Multi-speed Motors

    Surge Protection/lighting arrestors

    Various tests

    Mechanical

    Metric Dimensions on Frame and Shaft Roller Bearing

    RenkSleeve Bearings

    Special Grease

    Larger Diameter Shaft

    Longer Shaft Length

    Double Shaft Extensions

    Space Heaters

    WPII Enclosure Hoods (5000 frame and up)

    IEEE 841 Features

    Speed Feedback Devices

    Low audible noise designs available

    Conduit Box Volumes

    MotorFrame Size

    Baldor VolumeIn3

    NEMA Minimum VolumeIn3

    NPTHole Size

    444T/445T 600 600 2.5

    445T/447T 600 600 2.5

    447T/449T 1570 840 4

    5005/5006/5007 2100 2000 4 (2)

    5008/5009 2100 2000 4 (2)

    5010/5011 2100 2000 4 (2)

    5808/5809/5810/5812 3000 N/A 4 (3)

    Note: All Cast Iron construction. Lead separator gasket between box and frame is a neoprene rubber cone design for a water-tight seal around the lead wires.Conduit box lid gasket is neoprene rubber. Grounding provision is located inside the conduit box. Additional and/or larger conduit boxes are available.

    5000 frame TEFC motor with Renk sleeve bearings and RTD.

  • 7/22/2019 Motor Baldor Data Sheet

    22/32www.baldor.com1

    Dimensions

    C

    D

    E2F

    H

    N

    V

    O

    P

    U

    AA

    AB GREASE FITTING(EACH END)

    EBA

    B A

    AC

    KEY

    ODP 447T / 449T

    NEMAFRAME

    A B C D E 2F H N O P U V AA AB BA

    447TS 21.5 28 44.38 11 9 20 & 25 .81 5.13 22.47 22.93 2.375 4.75 4-NPT 20.47 7.5

    447T 21.5 28 48.12 11 9 20 & 25 .81 8.87 22.47 22.93 3.375 8.5 4-NPT 20.67 7.5

    449TS 21.5 28 44.38 11 9 20 & 25 .81 5.13 22.47 22.93 2.375 4.75 4-NPT 20.47 7.5

    449T 21.5 28 44.12 11 9 20 & 25 .81 8.87 22.47 22.93 3.375 8.5 4-NPT 20.67 7.5

    C

    LIFTING

    PROVISIONS

    2F

    2F

    BA

    AIR

    IN

    U

    KEY

    AIRIN

    N-W

    V

    EE

    A

    AC

    H

    4 NPT

    AA

    1 NPT

    D

    O

    AIR

    OUT

    P

    AB2.81

    ODP / WPI 449 / 5000 / 5800

    NEMAFRAME

    A B C D E 2F H N-W O P U V AA AB AC BA

    449TS 21.53 28.00 44.42 11.00 9.00 20 & 25 0.81 4.75 22.38 24.90 2.375 4.50 4-NPT 21.40 16.75 7.50

    449T 21.53 28.00 48.18 11.00 9.00 20 & 25 0.81 8.50 22.38 24.90 2.375 8.250 4-NPT 21.40 16.75 7.50

    5009S 30.06 36.40 51.75 12.50 10.00 22 & 25 & 28 0.94 6.75 28.32 38 2.500 6.50 4-NPT 27.87 21.90 8.50

    5009L 30.06 36.40 56.62 12.50 10.00 22 & 25 & 28 0.94 11.62 28.32 38 3.875 11.12 4-NPT 28.50 22.50 8.50

    5011S 30.06 43.40 59.75 12.50 10.00 32 & 36 0.94 6.75 28.32 38 2.500 6.50 4-NPT 28.75 22.75 8.50

    5011L 30.06 43.40 64.62 12.50 10.00 32 & 36 0.94 11.62 27.57 38 3.875 11.12 4-NPT 28.75 22.75 8.50

    5808S 35.50 38.63 54.25 14.50 11.50 22 & 25 & 28 1.18 6.75 33.25 44 3.375 6.50 4-NPT 32.00 25.88 9.75

    5808L 35.50 38.63 60 14.50 11.50 22 & 25 & 28 1.18 12.50 33.25 44 4.125 9.00 4-NPT 32.00 25.88 9.75

    5810S 35.50 44.63 62.25 14.50 11.50 28 & 32 & 36 1.18 6.75 33.38 44 3.375 6.50 4-NPT 32.00 25.88 9.75

    5810L 35.50 44.63 68 14.50 11.50 28 & 32 & 36 1.18 12.50 33.38 44 4.875 9.00 4-NPT 32.00 25.88 9.75

    Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may alsobe available from our CD-ROM or website at www.baldor.com.

  • 7/22/2019 Motor Baldor Data Sheet

    23/32www.baldor.com

    3.12

    C

    AIR EXHAUST

    V

    SOLID COVER

    2F

    2F

    BA

    N-W

    U

    P

    AB

    AIR

    INTAKE

    3.5

    2.0 O

    D

    HAC

    A

    2E

    G

    AA

    4.7

    2.81

    DimensionsWPII 5000/5800

    NEMAFRAME

    A B C D E 2F H N-W O P U V AA AB AC BA

    5009S 30.06 36.40 54.88 12.50 10.00 22 & 25 & 28 0.94 6.75 51.75 30 2.500 6.50 4-NPT 28.50 22.50 8.50

    5009L 30.06 36.40 59.75 12.50 10.00 22 & 25 & 28 0.94 11.62 51.75 30 3.875 11.12 4-NPT 28.50 22.50 8.50

    5011S 30.06 43.40 62.88 12.50 10.00 32 & 36 0.94 6.75 51.75 32.13 2.500 6.50 4-NPT 29.50 22.00 8.50

    5011L 30.06 43.40 67.75 12.50 10.00 32 & 36 0.94 11.62 51.75 32.13 3.875 11.12 4-NPT 29.50 22.00 8.50

    5808S 35.50 38.63 57.37 14.50 11.50 22 & 25 & 28 1.18 6.75 60 39 3.375 6.50 4-NPT 33.31 27.20 9.75

    5808L 35.50 38.63 63.0 14.50 11.50 22 & 25 & 28 1.18 11.25 60 39 4.125 9.00 4-NPT 33.31 27.20 9.75

    5810S 35.5 44.63 65.37 14.50 11.50 28 & 32 & 36 1.18 6.75 60 39 3.375 6.50 4-NPT 33.31 27.20 9.75

    5810L 35.5 44.63 71.0 14.50 11.50 28 & 32 & 36 1.18 11.25 60 39 4.875 9.00 4-NPT 33.31 27.20 9.75

    Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may alsobe available from our CD-ROM or website at www.baldor.com.

  • 7/22/2019 Motor Baldor Data Sheet

    24/32www.baldor.com3

    Dimensions

    SLINGER

    V

    2F

    B

    BA NH

    KEY

    U

    O

    D

    AB

    GREASER & RELIEF(EACH END)

    P

    AC

    E E

    A

    AA

    C

    TEFC 447T / 449T

    NEMAFRAME

    A B C D E 2F H N O P U V AA AB BA

    4411TS 21.75 36.70 57.05 11.00 9.00 25 & 28 & 32 0.81 4.93 22.94 25.25 2.375 4.75 4NPT 21.71 7.50

    4411TY 21.75 36.70 61.23 11.00 9.00 25 & 28 & 32 0.81 9.11 22.94 25.25 3.375 8.50 4NPT 21.71 7.50

    447TS 21.75 23.75 44.00 11.00 9.00 16.5 & 20 0.81 6.44 22.94 24.56 2.375 4.75 3 NPT 20.57 7.50

    447T 21.75 23.75 47.75 11.00 9.00 16.5 & 20 0.81 8.93 22.94 24.56 3.375 8.50 3 NPT 20.43 7.50

    449TS * 21.75 28.75 48.90 11.00 9.00 20 & 25 0.81 4.93 22.94 24.56 2.375 4.75 4-NPT 21.71 7.50

    449TS 21.75 28.75 48.90 11.00 9.00 20 & 25 0.81 5.19 22.94 24.56 2.375 4.75 4-NPT 21.71 7.50

    449T 21.75 28.75 52.65 11.00 9.00 20 & 25 0.81 8.94 22.94 24.56 3.375 8.50 4-NPT 21.71 7.50

    449TY 21.75 28.75 54.35 11.00 9.00 20 & 25 0.81 9.11 22.94 24.56 3.375 8.50 4-NPT 21.71 8.50

    *2-pole only, Design has shaft end bearing cooling fan

    C

    3/4 NPT

    H 2F

    B

    BA

    N-W

    V

    U

    AA EAC

    A

    AB

    P

    D

    O

    2NPT

    TEFC 5000

    NEMAFRAME

    Poles A B C D E 2F H N-W O P U V AA AB BA

    5007SY 2 25.65 28.4 54.03 12.50 10.00 18 & 20 & 22 0.94 6.75 26.84 29.90 2.500 6.50 4-NPT 26.88 9.87

    5007L 4 & 6 25.65 28.4 56.93 12.50 10.00 18 & 20 & 22 0.94 11.62 26.84 29.90 3.875 11.12 4-NPT 26.88 8.50

    5009SY 2 25.65 34.4 60.03 12.50 10.00 25 & 28 0.94 6.75 26.84 29.90 2.500 6.50 4-NPT 26.88 9.87

    5009L 4 & 6 25.65 34.4 62.93 12.50 10.00 25 & 28 0.94 11.62 26.84 29.90 3.875 11.12 4-NPT 26.88 8.50

    5011LY 4 & 6 25.65 42.4 72.05 12.50 10.00 32 & 36 0.94 11.54 26.84 29.90 3.875 11.12 4-NPT 26.88 9.71

    Note: Drawings shown are for reference only. Please contact Baldor for adetailed dimensional drawing of the specific motor you require. Drawingsmay also be available from our CD-ROM or website at www.baldor.com.

  • 7/22/2019 Motor Baldor Data Sheet

    25/32www.baldor.com

    DimensionsTEFC 5800

    C

    B

    BA2F

    H N-W

    V

    KEY

    U

    4 NPT

    AA

    E E

    AC

    A

    1 NPT

    P

    D

    O

    AB

    NEMAFRAME

    A B C D E 2F H N-W O P U V AA AB AC BA

    5810 32.00 42.40 75.18 14.50 11.50 28 & 32 & 36 1.18 12.50 34.00 33.00 4.125 11.00 4-NPT 30.19 24.50 11.38

    5812 32.00 51.40 81.77 14.50 11.50 40 & 45 1.18 9.00 34.00 33.00 4.125 8.75 4-NPT 30.19 24.50 11.84

    Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may also be available fromour CD-ROM or website at www.baldor.com.

  • 7/22/2019 Motor Baldor Data Sheet

    26/32www.baldor.com5

    TEBC Inverter/Vector

    4.7AA HOLE AC E 1.44

    2C

    A

    AB42.5 REF.

    P

    46.9

    G

    VOLUME

    160 IN 3

    2-NPT

    1/4 DIA.

    TYP. 4

    N-W

    V

    U

    C

    BA3.79

    2F

    B

    17.59

    9.65

    H HOLE

    ENCODER MTG.

    (OPPOSITE SIDE)

    1/2 NPT

    C/BOX FOR

    BLOWER MOTOR

    NEMA

    FRAME

    A B C D E 2F H N-W O P U V AA AB AH AJ AK BA BB BD TAP

    449TC* 21.75 28.75 64.37 11.00 9.00 20 & 25 0.81 24.55 24.55 3.375 8.5 4-NPT 21.71 8.25 14.00 16.00 7.50 0.25 16.75 5/8-11

    5007L 25.65 28.40 68.06 12.50 10.00 18 & 20 & 22 0.94 11.62 26.84 29.90 3.875 11.12 4-NPT 26.88 8.50

    5009L 25.65 34.40 74.05 12.50 10.00 25 & 28 0.94 11.62 26.84 29.90 3.875 11.12 4-NPT 26.88 8.50

    5011LY 25.60 42.40 85.87 12.50 10.00 32 & 36 0.94 11.54 26.84 29.90 3.875 11.12 4-NPT 26.88 9.71

    5810 32.00 42.40 87.96 14.50 11.50 28 & 32 & 36 1.18 12.50 34.00 33.00 4.125 11.00 4-NPT 30.19 11.38

    5812 32.00 51.40 95.96 14.50 11.50 40 & 45 1.18 12.50 34.00 33.00 4.125 11.00 4-NPT 30.19 11.38

    * Only 449TC stock motor designs have frame with standard C-face

    Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may also be available fromour CD-ROM or website at www.baldor.com.

    Dimensions

  • 7/22/2019 Motor Baldor Data Sheet

    27/32www.baldor.com

    Dimensions

    TEFC Explosion Proof 449T

    HB

    2FBA

    U

    KEY

    NV

    C

    GREASE RELIEF

    (EACH END)

    E E

    AC

    A

    AA

    O

    D

    AB

    P

    NEMAFRAME

    A B C D E 2F H-W N O P U V AA AB BA

    445TS 21.75 20.25 40.50 11.00 9.00 14.5 & 16.5 0.81 4.90 22.91 24.81 2.375 4.75 3-NPT 23.6 7.50

    445T 21.75 20.25 44.25 11.00 9.00 14.5 & 16.5 0.81 8.75 22.91 24.81 3.375 8.50 3-NPT 23.6 7.50

    449TS 21.75 28.75 49.00 11.00 9.00 20 & 25 0.81 4.94 22.94 24.81 2.375 4.75 3-NPT 27.67 7.50

    449T 21.75 28.75 52.75 11.00 9.00 20 & 25 0.81 8.72 22.94 24.81 3.375 8.50 3-NPT 27.67 7.50

    449TY 21.75 28.75 54.25 11.00 9.00 20 & 25 0.81 8.72 22.94 24.81 3.375 8.50 3-NPT 27.67 9.00

    Note: Drawings shown are for reference only. Please contact Baldor for a detailed dimensional drawing of the specific motor you require. Drawings may also beavailable from our CD-ROM or website at www.baldor.com.

    Limited WarrantyThree years on Super-E, 24 months on Standard-E, 18 months on most other motors, 5 years on IEEE841.

  • 7/22/2019 Motor Baldor Data Sheet

    28/32www.baldor.com7

    OPTIONAL T'STATSP1

    24 7

    58

    3

    P2

    96

    1

    LOW VOLTAGE

    (2D)

    HIGH VOLTAGE

    (1D)

    7 8 9

    6 4 5

    1 2 3

    7 8 9

    4 5 6

    1 2 3

    LINE LINE

    Connection Diagrams Main Motor Power Leads

    OPTIONAL T'STATS LOW VOLTAGE HIGH VOLTAGEP1

    P2

    58

    23

    69

    7

    4

    1

    7 8 9

    1 2 3

    4 5 6

    321

    7 8 9

    4 5 6

    LINELINE

    2Y 1Y

    9 Lead

    Wye-Connected Motor

    9 Lead

    Delta-Connected Motor

    Notes:

    1. Three lead motors may be designed as either wye-connected or delta-connected.

    2. Interchange any two line leads to reverse rotation.

    3. Optional thermostats are provided when specified.

    4. Actual number of internal parallel circuits may vary.

  • 7/22/2019 Motor Baldor Data Sheet

    29/32www.baldor.com

    TYPICAL WYE- CONNECTED MOTOR

    OPTIONAL T'STATS

    1 2 3

    LINE

    TYPICAL DELTA - CONNECTED MOTOR

    OPTIONAL T'STATS

    P1

    21

    3

    P223

    1P1

    P2

    Connection Diagrams Main Motor Power Leads

    3 Lead

    Notes:

    1. Three lead motors may be designed as either wye-connected or delta-connected.

    2. Interchange any two line leads to reverse rotation.

    3. Optional thermostats are provided when specified.

    4. Actual number of internal parallel circuits may vary.

    NEMA Standard Lead MarkingsLead Marking Motor

    Power Leads T1, T2, T3, etc.

    Thermostat P1, P2, etc.

    Space Heater H1, H2, H3, H4, etc.

    Winding Resistance Temperature

    Detector (RTD)R1, R2, R3, R4, etc.

  • 7/22/2019 Motor Baldor Data Sheet

    30/32www.baldor.com9

    Encoder Receptacle ConnectionsFor Vector Drive Motors

    PIN FUNCTION

    A A

    B B

    C Z(C)

    D VDC (5-15 VDC Standard)

    E Shield

    F Circuit Ground

    G Case Ground

    H A Compliment (A)

    J B Compliment (B)

    K Z (C) Compliment (Z or C)

    F

    E

    A

    B

    C

    D

    G

    H

    JK

    Standard Receptacle MS3112E12-10P (Baldor Part # WD1434)

    Standard Plug MS3116J12-10S (Baldor Part # WD1435)

    Both receptacle and plug are provided with the motor. Note that together these connections are weatherproof.

    Mod-ExpressIn addition to the Chemical Processing motors shown in this brochure that are available from stock, customized

    motors are available for special requirements on OEM applications. Baldors short lead times

    can supply the motor for your specific application with special voltage, base speed, Design C torque, C-Face,

    D-Flange, IEC metric dimensions, or other application-based needs. Special motors are in use on mixers,

    aerators, crushers, centrifuges, hoists, pumps, and HVAC equipment.

    Motors may be taken from Baldors Fort Smith inventory and modified through our Mod-Express program.

    These modifications include:

    Dynamic Balance of Rotor

    InproSeal

    F-2 Conversion

    Special Performance Tests

    Roller Bearings

    Bearing Thermocouples, Thermistors or RTDs

    Space Heaters

    Winding Thermocouples, Thermistors or RTDs

    Vibration LevelsVibration levels are in accordance with NEMA MG-1 section 12.06.

  • 7/22/2019 Motor Baldor Data Sheet

    31/32www.baldor.com

  • 7/22/2019 Motor Baldor Data Sheet

    32/32

    Contact your nearest Baldor District Office at theseWorld Wide locations, or visit www.baldor.com

    Baldor Electric Company

    PO B 2400

    KOREA ROOM 208-37 INCHEON INDUSTRIAL GOODS CIRCULATING CENTER

    SONGHYEON 3-DONG, DONG-GU INCHEON. KOREA, 401-705 PHONE: 82 32 588 3253 FAX: 82 32 588 3254

    MXICO KM. 2.0 BLVD. AL AEROPUERTO LEN 37545, GUANAJUATO, MXICO PHONE: 52 477 761 2030 FAX: 52 477 761 2010

    MIDDLE EAST & NORTH AFRICA VSE INTERNATIONAL CORP. 3233 NORTH ARLINGTON HEIGHTS

    SUITE 100W ARLINGTON HEIGHTS, IL 60004 PHONE: 847 590 5547

    SINGAPORE 51 KAKI BUKIT ROAD 2 K B WAREHOUSE COMPLEX SINGAPORE 417863 PHONE: (65) 6 744 2572

    FAX: (65) 6 747 1708

    SWITZERLAND POSTFACH 73 SCHUTZENSTRASSE 59 CH-8245 FEUERTHALEN SWITZERLAND PHONE: (41) (52) 6474700 FAX: (41) (52) 6592394

    TAIWAN 4F, NO. 25, SEC. 1, TUNHUA S ROAD, TAIPEI 10557, TAIWAN, R.O.C. PHONE: (886-2) 2577-4352 FAX: (886-2) 2577-4157

    UNITED KINGDOM 6 BRISTOL DISTRIBUTION PARK HAWKLEY DRIVE BRISTOL BS32 0BF U.K. PHONE: 44 1454 859000 FAX: 44 1454 8590019

    NEW YORK AUBURN ONE ELLIS DRIVE AUBURN, NY 13021

    PHONE: 315-255-3403 FAX: 315-253-9923

    NORTH CAROLINA GREENSBORO 1220 ROTHERWOOD ROAD GREENSBORO, NC 27406 P O BOX 16500 GREENSBORO, NC 27416 PHONE: 336-272-6104 FAX: 336-273-6628

    OHIO CINCINNATI 2929 CRESCENTVILLE ROAD WEST CHESTER, OH 45069 PHONE: 513-771-2600 FAX: 513-772-2219

    CLEVELAND 8929 FREEWAY DRIVE MACEDONIA, OH 44056 PHONE: 330-468-4777 FAX: 330-468-4778

    OKLAHOMA TULSA 2 EAST DAWES

    BIXBY, OK 74008 PHONE: 918-366-9320 FAX: 918-366-9338

    OREGON PORTLAND 20393 SW AVERY COURT TUALATIN, OR 97062 PHONE: 503-691-9010 FAX: 503-691-9012

    PENNSYLVANIA PHILADELPHIA 1035 THOMAS BUSCH

    MEMORIAL HIGHWAY PENNSAUKEN, NJ 08110 PHONE: 856-661-1442 FAX: 856-663-6363

    PITTSBURGH 616H BEATTY ROAD MONROEVILLE, PA 15146 PHONE: 412-380-7244 FAX: 412-380-7250

    TENNESSEEMEMPHIS

    4000 WINCHESTER ROAD MEMPHIS, TN 38118 PHONE: 901-365-2020 FAX: 901-365-3914

    INDIANA INDIANAPOLIS 5525 W. MINNESOTA STREET INDIANAPOLIS, IN 46241

    PHONE: 317-246-5100 FAX: 317-246-5110 800-428-4141

    IOWA DES MOINES 1800 DIXON STREET, SUITE C DES MOINES, IA 50316 PHONE: 515-263-6929 FAX: 515-263-6515

    MARYLAND BALTIMORE 6660 SANTA BARBARA RD. SUITE 22-24 ELKRIDGE, MD 21075 PHONE: 410-579-2135 FAX: 410-579-2677

    MASSACHUSETTS BOSTON 6 PULLMAN STREET WORCESTER, MA 01606 PHONE: 508-854-0708

    FAX: 508-854-0291

    MICHIGAN DETROIT 33782 STERLING PONDS BLVD. STERLING HEIGHTS, MI 48312 PHONE: 586-978-9800 FAX: 586-978-9969

    GRAND RAPIDS 668 3 MILE ROAD NW GRAND RAPIDS, MI 49504 PHONE: 616-785-1784 FAX: 616-785-1788

    MINNESOTA MINNEAPOLIS 21080 134TH AVE. NORTH ROGERS, MN 55374

    PHONE: 763-428-3633 FAX: 763-428-4551

    MISSOURI

    ST LOUIS 422 INDUSTRIAL DRIVE MARYLAND HEIGHTS, MO 63043 PHONE: 314-298-1800 FAX: 314-298-7660

    KANSAS CITY 1501 BEDFORD AVENUE NORTH KANSAS CITY, MO 64116 PHONE: 816-587-0272 FAX: 816-587-3735

    TEXAS HOUSTON 4647 PINE TIMBERS SUITE # 135

    HOUSTON, TX 77041 PHONE: 713-895-7062 FAX: 713-690-4540

    DALLAS 3040 QUEBEC DALLAS, TX 75247 PHONE: 214-634-7271 FAX: 214-634-8874

    UTAH SALT LAKE CITY 2230 SOUTH MAIN STREET SALT LAKE CITY, UT 84115 PHONE: 801-832-0127 FAX: 801-832-8911

    WISCONSIN MILWAUKEE 2725 SOUTH 163RD STREET NEW BERLIN, WI 53151 PHONE: 262-784-5940 FAX: 262-784-1215

    INTERNATIONAL SALESFORT SMITH, AR

    P.O. BOX 2400 FORT SMITH, AR 72902 PHONE: 479-646-4711 FAX: 479-648-5895

    CANADA EDMONTON, ALBERTA 4053-92 STREET EDMONTON, ALBERTA T6E 6R8 PHONE: 780-434-4900 FAX: 780-438-2600

    OAKVILLE, ONTARIO 2750 COVENTRY ROAD OAKVILLE, ONTARIO L6H 6R1 PHONE: 905-829-3301 FAX: 905-829-3302

    MONTREAL, QUEBEC 1844 WILLIAM STREET MONTREAL, QUEBEC H3J 1R5

    PHONE: 514-933-2711 FAX: 514-933-8639

    VANCOUVER,BRITISH COLUMBIA

    1538 KEBET WAY PORT COQUITLAM, BC V3C 5M5 PHONE 604-421-2822 FAX: 604-421-3113

    WINNIPEG, MANITOBA 54 PRINCESS STREET WINNIPEG, MANITOBA R3B 1K2 PHONE: 204-942-5205 FAX: 204-956-4251

    AUSTRALIA UNIT 3, 6 STANTON ROAD SEVEN HILLS, NSW 2147,

    AUSTRALIA

    PHONE: (61) (2) 9674 5455 FAX: (61) (2) 9674 2495

    UNIT 8, 5 KELLETTS ROAD ROWVILLE, VICTORIA, 3178

    AUSTRALIA PHONE: (61) (3) 9753 4355 FAX: (61) (3) 9753 4366

    AMRICA DEL SUR APTDO. 9109 0818 ZONA 6 BETHANIA, CIUDAD DE PANAM, PANAM PHONE: +507 261-5347 FAX: +507 261-5355

    CENTRO AMRICA Y CARIBE RESIDENCIAL PINARES DE SUIZA POL. 15 #44, NVA. SAN SALVADOR,

    EL SALVADOR PHONE: +503 2288-1519 FAX: +503 2288-1518

    CHINA SHANGHAI JIAHUA

    BUSINESS CENTER ROOM NO. A-8421 808 HONG QIAO ROAD SHANGHAI 200030 PHONE: 86-21-64473060 FAX: 86-21-64078620

    GERMANY DIESELSTRASSE 22 D-85551 KIRCHHEIM

    MUNICH, GERMANY PHONE: (49) (89) 90508 0 FAX: (49) (89) 90508 492

    INDIA 14, COMMERCE AVENUE MAHAGANESH COLONY PAUD ROAD PUNE - 411 038 MAHARASHTRA, INDIA PHONE: 91 20 25 45 95 30

    FAX: 91 20 5 4 95 30

    ITALY BALDOR ASR AG SUCCURSALE DI MENDRISIO VIA BORROMINI, 20A CH-6850 MENDRISIO SWITZERLAND PHONE: 41 91 640 9952 FAX: 41 91 630 2633

    JAPAN DIA BLDG 802, 2-21-1 TSURUYA-CHO,

    KANAGAWA-KU YOKOHAMA, 221-0835, JAPAN PHONE: 81-45-412-4506 FAX: 81-45-412-4507

    UNITED STATES

    ARIZONA PHOENIX

    4211 S 43RD PLACE PHOENIX, AZ 85040 PHONE: 602-470-0407 FAX: 602-470-0464

    ARKANSAS CLARKSVILLE 1001 COLLEGE AVE. CLARKSVILLE, AR 72830 PHONE: 479-754-9108 FAX: 479-754-9205

    CALIFORNIA LOS ANGELES 6480 FLOTILLA

    COMMERCE, CA 90040 PHONE: 323-724-6771 FAX: 323-721-5859

    HAYWARD 21056 FORBES STREET HAYWARD, CA 94545 PHONE: 510-785-9900 FAX: 510-785-9910

    COLORADO DENVER 2520 W BARBERRY PLACE DENVER, CO 80204 PHONE: 303-623-0127 FAX: 303-595-3772

    CONNECTICUT WALLINGFORD 65 SOUTH TURNPIKE ROAD WALLINGFORD, CT 06492 PHONE: 203-269-1354 FAX: 203-269-5485

    FLORIDA TAMPA/PUERTO RICO/ VIRGIN ISLANDS 3906 EAST 11TH AVENUE TAMPA, FL 33605 PHONE: 813-248-5078 FAX: 813-247-2984

    GEORGIA ATLANTA 62 TECHNOLOGY DR.

    ALPHARETTA, GA 30005 PHONE: 770-772-7000 FAX: 770-772-7200

    ILLINOIS CHICAGO 1601 FRONTENAC ROAD NAPERVILLE, IL 60563 PHONE: 630-848-5100 FAX: 630-848-5110