Top Banner
Helvar | Data subject to change without notice www.helvar.com 1 Modular LCM Datasheet and Installation Guide Overview The modular LCM is a cost effective method of providing power and control for lighting installations in industrial, commercial and retail buildings. The system is designed for ease of installation: mains input is connected using the spacious wiring compartment, DALI control inputs and outputs are pluggable using industry standard connectors. The modular approach allows for between 2 and 16 luminaires to be connected. System Components Note: Allow 150mm for total height of unit (including connectors and cable) 159mm 202mm 122mm Fixing point 127mm 75mm 150mm 105mm 146mm BVITM6-S2-HELVAR 2 Output Starter Module BVITM6-S-HELVAR 4 Output Starter Module BVITM6-E-HELVAR 4 Output Extender Module
8

Modular LCM Datasheet and Installation Guide - Helvar · 2019. 10. 30. · Helvar Data subect to change without notice 1 Modular LCM Datasheet and Installation Guide Overview The

Jan 19, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Modular LCM Datasheet and Installation Guide - Helvar · 2019. 10. 30. · Helvar Data subect to change without notice 1 Modular LCM Datasheet and Installation Guide Overview The

Helvar | Data subject to change without notice www.helvar.com 1

Modular LCM Datasheet and Installation GuideOverviewThe modular LCM is a cost effective method of providing power and control for lighting installations in industrial, commercial and retail buildings. The system is designed for ease of installation: mains input is connected using the spacious wiring compartment, DALI control inputs and outputs are pluggable using industry standard connectors. The modular approach allows for between 2 and 16 luminaires to be connected.

System Components

Note: Allow 150mm for total height of unit (including connectors and cable)

159mm 202mm 122mmFixing point

127mm

75mm150mm105mm

146m

m

BVITM6-S2-HELVAR 2 Output Starter Module

BVITM6-S-HELVAR4 Output Starter Module

BVITM6-E-HELVAR4 Output Extender Module

Page 2: Modular LCM Datasheet and Installation Guide - Helvar · 2019. 10. 30. · Helvar Data subect to change without notice 1 Modular LCM Datasheet and Installation Guide Overview The

Helvar | Modular LCM Installation Guide www.helvar.com 2

Installation of Box

4 x key slots to accept M6 (1/4”) fixings BESA box fittings

Channel for channel nuts (zebs)

Removable gland plate with 3 x

Ø20mm knockouts

3 x Ø20mm knockouts for rear cable entry

The box should be fixed on a smooth, flat surface or using drop rod fixings attached to channel nuts.

Ensure that there is easy access to the wiring compartment and all connectors once the box is in-situ.

Warning: This device works at mains voltage. Be sure to take care when working with electricity.

Page 3: Modular LCM Datasheet and Installation Guide - Helvar · 2019. 10. 30. · Helvar Data subect to change without notice 1 Modular LCM Datasheet and Installation Guide Overview The

Helvar | Data subject to change without notice www.helvar.com 3

Example Network Diagram (Imagine Router System)

L, N

, E

Note

: Rou

ter

supp

ly m

ust b

e pr

otec

ted

at 6

A

max

imum

.

Pow

erPL

, SW

L, N

, E

DALI

DA+,

DA-

PL, N

, E,

DA+,

DA-

SWL,

N, E

, DA

+, D

A-

E

DALI

Em

erge

ncy

Lum

inai

reDA

LI L

umin

aire

Sens

orDA+,

DA- Bu

tton

Mod

ules

Switc

h In

puts

Emer

genc

y Lu

min

aire

Rout

er D

ALI S

ubne

t Lim

itatio

ns

300m

max

cab

le ru

n64

add

ress

es24

0mA

Exam

ple:

Indi

cativ

e sy

stem

sch

emat

ic o

nly.

Max

5 x

LCM

s pe

r DAL

I sub

net (

aver

age

10 p

ort L

CM +

1 s

enso

r + 1

Sw

itch

inpu

t).Co

ntra

ctor

mus

t pro

vide

app

ropr

iate

isol

atio

n, c

ablin

g an

d re

fere

nce

othe

r sys

tem

com

pone

nt in

stal

l gui

des.

PL, N

, E

E

Ethe

rnet

Imag

ine

910

Rout

er(M

ount

ed in

rest

ricte

d ac

cess

loca

tion)

.

Page 4: Modular LCM Datasheet and Installation Guide - Helvar · 2019. 10. 30. · Helvar Data subect to change without notice 1 Modular LCM Datasheet and Installation Guide Overview The

Helvar | Modular LCM Installation Guide www.helvar.com 4

Wiring

Cable Clamps

Large cables

Luminaire connectors/Lead colours

Small cables

DIM+ (DALI+) Red

DIM- (DALI -) White

Permanent Live Black (6 core only)

Neutral Blue

Earth Green/Yellow

Switched Live Brown

DALI+ DALI -

Permanent Live

Neutral

Earth

Switched LiveNot for useNot for use

LiveWarning: For correct installation, connector plugs must be fully engaged and latched on both sides.

• All wiring must be mains rated.• Remove wiring compartment cover.• Wire the box using the diagrams below. Switched Live for normal fittings Permanent live feeds emergency fittings• Use the cable clamps to secure the wiring or use cable glands (not supplied). The clamps can be split, and flipped over to clamp different cable diameters.• Replace wiring compartment cover.• Plug in the luminaires ensuring that the connector latches to the box.

Note: Live is NOT internally connected and NOT fed through to outputs. See page 5.

Page 5: Modular LCM Datasheet and Installation Guide - Helvar · 2019. 10. 30. · Helvar Data subect to change without notice 1 Modular LCM Datasheet and Installation Guide Overview The

Helvar | Data subject to change without notice www.helvar.com 5

Wiring Layout and Emergency Test

Local lighting switch and local emergency test switch

Emergency test using power interruption

Emergency test using central switch

Warning: Do not wire across phases

DA+

DA-

DA+DA-

Central emergency

test switch or controllable relay

e.g. Helvar 492

Wire link

DA+

DA-Local emergency

test switch

N E L

N E L

N E L Multiple boxes

Page 6: Modular LCM Datasheet and Installation Guide - Helvar · 2019. 10. 30. · Helvar Data subect to change without notice 1 Modular LCM Datasheet and Installation Guide Overview The

Helvar | Modular LCM Installation Guide www.helvar.com 6

WDA0057860412 Issue 022019-09-23

Part numbers

Ratings

Modules

BVITM6-S-HELVAR 4 output starter moduleBVITM6-S2-HELVAR 2 output starter moduleBVITM6-E-HELVAR 4 output extender module

Connectors

BVITM6-LPR 6 pole luminaire plug redBVITM6-LPW 6 pole luminaire plug white

Voltage 230VAC +/- 10%Frequency 50HzTerminal Capacity 4mm2 in wiring compartmentTemperature 00C to 350CPower Rating system 16A. Rating of each output 10ACompliance BS5733:2010

?

Helvar Ltd, Hawley Mill, Hawley Road, Dartford. DA2 7SY. UKwww.helvar.com+44 (0) 1322 617200

Warning: For lighting purposes with suitable circuit protection. For fixed wiring only.

Important: This device should be installed by a qualified electrician in accordance with the latest edition of the IEE wiring regulations

UK Patent no. GB2463063EU Patent pendingEU Registered design no. 001587544-0001, 001587544-0002

Page 7: Modular LCM Datasheet and Installation Guide - Helvar · 2019. 10. 30. · Helvar Data subect to change without notice 1 Modular LCM Datasheet and Installation Guide Overview The

Helvar | Data subject to change without notice www.helvar.com 7

Page intentionally blank

Page 8: Modular LCM Datasheet and Installation Guide - Helvar · 2019. 10. 30. · Helvar Data subect to change without notice 1 Modular LCM Datasheet and Installation Guide Overview The

Helvar | Modular LCM Installation Guide www.helvar.com 8