Page 1: Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.

Modine 93% Separated Combustion Condensing Unit

Modine’s Breakthrough Solution to Commercial

Heating

Page 2: Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.

The Next Leap Forward

Question: What is Modine’s breakthrough solution to the issues of commercial heating?

Answer: Modine’s NEW Effinity 93 with Conservicore™ Technology

– PTC-Series 93% Thermal Efficient Condensing Gas-Fired Unit Heater

Timing

Literature & Pricing Currently Available

Full Production September 2009

Page 3: Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.

Effinity 93 Design Features

Unit Components

Bent Tube PrimaryHeat Exchanger

AL29-4C Stainless SteelRound Tube Plate Fin

Secondary Heat Exchanger

Gas Manifold,Orifices & Burners

Propeller Fan& Motor

PowerExhauster

Fresh CombustionAir Intake

Flue GasExhaust

CondensateDrain

Page 4: Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.

The Heart and Soul…

Secondary Heat Exchanger Made With AL29-4C Stainless Steel Material

Most Robust Material Available to Withstand Acidic Condensate

Condensate Production

Approx. 1+ Gallons/hr for Small Units

Approx. 2+ Gallons/hr for Large Units

Slightly Acidic – Like Soda (Pop)

Need to Drain Both Unit & Vent System

Effinity 93 Design Features

Page 5: Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.

Effinity 93 Design Features

Separated Combustion

– Protects Heat Exchangers & Components from High Humidity & Chemical Corrosives

– Reduces Greenhouse Heat Loss by 2%

Propeller Fans

PVC Power Exhauster Wheel & Vent Pipe

– Flue Temperatures Only Around 125º F

Factory Installed External Junction Box Standard

– Disconnect Switch

– Convenience Outlet

– Terminal Board

– Indicator Lights

Page 6: Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.

PTC-Series Condensing Unit Heaters

PTC Outputs Closely Match Outputs of Standard Efficiency Units for Ease of Comparison When Sizing & Selecting New

Construction, Expansion or Replacement Jobs

• PTC135 output equates to 80% 150MBH output• PTC155 output equates to 80% 175MBH output• PTC180 output equates to 80% 200MBH output• PTC215 output equates to 80% 250MBH output• PTC260 output equates to 80% 300MBH output• PTC310 output equates to 80% 350MBH output

Page 7: Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.

Effinity 93 Application Flexibility

Options & Accessories

Stainless Steel Primary Heat Exchangers

– Recommended for Greenhouse Applications Due to Humidity

Finger-Proof (OSHA) Fan Guards

Step-Down Transformers

Concentric Vent Kits

Condensate Pumps & Neutralizer Kits

2-Point Suspension Kits

Deflector Hoods & Vertical Deflector Blades

Thermostats

Energy Saver Kit

– Ceiling T-Stat Energizes Fan Without Burner as Ceiling Temps Rises

Page 8: Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.

Effinity 93 Benefits

What This Means to the Building OwnerGrower

17% Fuel Savings Over Standard Power Vented & Separated Combustion Units

40% Fuel Savings Over Natural Draft Gravity Vented Units!!!

May Qualify for Local Rebate & Tax Incentive Programs

Separated Combustion Advantages– Reduced Air Changes & Heating Loads– Longer Lasting Heat Exchangers, Burners & Controls

PVC Vent Pipe & Power Exhauster Wheels– Lower Installed Costs & Replacement Costs vs. Metal

All Other Advantages of Gas-Fired Unit Heaters Apply– Warm Air Circulation, Vented Flue Products, Redundancy, Heat De-Stratification, Zone

Control, Low Installed Costs, etc.

Direct-Fired Efficiencies Without Direct-Fired Disadvantages– Water Vapor, Ethylene, Required Air Changes

Boiler Efficiencies Without Boiler System Disadvantages– High Up-Front Costs, Mechanical Rooms, Piping System Complexity, No Redundancy, Lower

Water Temperatures

Page 9: Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.

Effinity 93 Fuel Savings & Payback Calculator

Page 10: Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.

State & Local Efficiency Incentives

www.dsireusa.org

Renewables & Efficiency Incentive Programs

Searches by State, Program Type, Technology Type, etc.

– Helps Offset Costs to Upgrade to High Efficiency Equipment

– Significantly Reduces Payback Period

– May Find Incentives for Other Efficiency Upgrades Such as Thermal Blankets, Caulking & Insulation, High Efficiency Motors, Lighting, etc.

Page 11: Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.

For More Information…

Modine.com\Building HVAC\Greenhouse Heating Solutions

Page 12: Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.

MODEL PTCHIGH EFFICIENCY CONDENSING GAS FIRED UH