AIR CONDITIONING NOTES 1•- A/C CONTRACTOR SHALL: A) VERIFY All SPACE CONDillONS AND DIMENSIONS AT JOB SITE PRIOR THE CONSTRUCTION OF DUCTWORK AND INSTALlATION OF ANY EQUIPMENTS. B) COORDINATE ALL WORK WITH OTHER TRADES. (REVIEW ALL PLANS) C) DO All WORK IN ACCORDANCE WITH STATE AND LOCAL CODES. D) DO ALL WORK IN ACCORDANCE WITH LATEST ASHRAE GUIDE AND SMACNA STANDARDS. COMPLY WITH ALL RECOMMENDATIONS AND INSTRUCTIONS OF SMACNA STANDARDS AND THE EQUIPMENTS MANUFACTURERS. E) ADJUST AND BALANCE DIFFUSERS IN ACCORDANCE WITH QUANTITIES SHOWN ON PLANS. (LATESTS NAnONAL ENVIRONMENTAL BALANCING BUREAU PROCEDUAL STANDARDS OR AABC NAnONAL STANDARDS F) SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL 2.- GUARANnEES: A) All NEW EQUIPMENTS, PARTS AND MATERIALS SHALL BE GUARANnEED FOR ONE YEAR AFnER DATE OF ACCEPTANCE. B) PROVIDE 90 DAYS FREE SERVICE. 3.- TYPICAL AIR CONDITIONIND DUCTWORK (READ NOTES} A) SHALL BE CONSTRUCTED OF STANDARD DUTY FIBERGLASS BOARD FLAME- PROOF REINFORCED ALUMINUM FACED COVER IN ACCORDANCE WITH FBC AND NFIPA LATEST GUIDES; AS MANUFACTURED BY OWENS-CORNING. INSTALL AIR VOLUME EXTRACTORS, TURNING VANES OR AIR SCOOPS AT EACH DUCT TAP. FIBERGLASS DUCT BOARD R VALUE TO BE MINIMUM 4.2 AT COND. SPACES AND 6.0 AT NON CONDillONED SPACES, SUCH AS ATTICS. B) All DUCTWORK SHALL BE CONSTRUCTED AND ERECTED IN ACCORDANCE WITH THE PROVISIONS OF THE LATEST nMA CONSTRUCTION STANDARDS AND AS PER FBC-CHAPTER 6 - SECTION 603. 4.- EXHAUST OR VENnLAnON DUCTWORK: A) SHALL BE CONSTRUCTED AS PER FBC-CHAPTER 5, FROM GALVANIZED SHEET METAL IN ACCORDANCE WITH ASHRAE AND SMACNA STANDARDS, TERMINATED OUTSIDE THE BLDG. AND EQUIPPED WITH A BACKDRAFT DAMPER. (THERMOFIN ALLOWED) B) CLOTHES EXH. DRYER DUCT SHALL NOT BE SCREENED (4" MIN) 8c CONSTRUCTED OF A MIN. 0.01 6 INCHES THICK OR 26 GAUGE METAL PIPE HAVING A SMOOTH INTERIOR SURFACE WI JOINTS IN THE DIRECTION OF THE AIR FILOW NO SCREWS OR FASnENERS EXnENDED INTO THE DUCTS AS PER FMCR-M1502.4. 1 C) BATHROOM EXHAUST DUCTS TO BE CONSTRUCTED OF A MIN. 30 GAUGE (GALVANIZED) OR 26 GAUGE (ALUMINUM} AND DISCHARGE TO THE OUTSIDE OF THE BLDG. SHALL BE TERMINATED NOT LESS THAN 6" ABOVE THE FINISHED ROOF SURFACE AND SHALL BE SCREENED WITH A CORROSION RESISTANT MATERIAL, MESH SIZE NOT LARGER THAN 1/2" (GOOSENECK OR RAIN CAP ON ROOF TERMINAnON). D) A UL CERTIFIED RESIDENTIAL RECIRCULAnNG KITCHEN EXHAUST HOOD SHALL BE INSTALLED AT KITCHEN. NOnE: .AI I PERFORATED VENT CAP 12"MIN. /UNION SLOPE 1/8"/ FT. f- AIC UNIT ll I / [ J I DRAIN PAN 314" MIN._/ f- f- -- / \._3"MIN. CONDENSATE DRAIN TRAP DETAIL FLOAT SWITCH TO SHUT-DOWN EQUIP. AS PER FMC. 301.13 (EZ-TRAP SERIES 200) INSTALLED INSIDE OF DRAIN PAN FBC. R-M 1411.3.1.1 REMOVABLE CAP OVERFILOW I RAIN LINE N.T.S. 3/4" A/C UNIT DRAIN PAN DRAIN LINE AUX. OVERF'LOW DRAIN LINE DETAIL N.T.S. STEEL CAGE W/ACCESS DOOR ./FOR SECURITY OF A/C COMPRESSOR ' I II COND UNIT TO BE AT OR ABOVE FLOOR I I Ill Ill UEVELf GALVANIZED ,----------,/ ·.··LI·. NE COVER CBS WALL BOLT CONDENSING UNIT TO f-;; f ·... SUPPORTS TO WITHSTAND _____ c-j 170 MPH HURRICANE 1 FORCE WINOS AS PER I I L F...c.B::..c.C::..c ....:2:.:0..:.1 0:...______, "-;--- --+-11-tl I II" 12" MIN. 4" CONCRETE PAO (SEE ELEVATION ON SITE PLAN) FINISHED GRADE NOTE: I I CONDENSING UNIT SHALL BE ANCHORED TO THE CONCRETE SLAB, ON THE INSIDE OF THE UNIT WrlH (1) 1/2"f SUP-R-STUD (4 1/2" MIN. EMBEDMENT) PER EACH CORNER (1YPICAL). NOA: 10-0928-01 EXP., 03-03-2016 (SEE CALCULAnONS ATIACHED). EFRIGERANT NES-""'" FINISHED FLOOR TYPICAL CONDENSING UNIT MOUNTING DETAIL N.T.S. UNIT NUMBER / QUANTITY AHU-1 I 1 MANUFACTURER PAYNE MODEL PF4MNB037TOO E-o .... NOM. TONS 2.5 z TOTAL CAPACITY / SENSIBLE 288oo 1 2o6oo t.!l TOTAL C.F.M. 1000 z S. E. E. R. 16.0 WEIGHT (LBS.) 157 z VOLTAGE 240-1-60 < MOTOR TYPE X-13 ::= FAN MOTOR H.P. I F.LA 1/2 I 4.1 KW / BTUH 8.o I < HEATER 27304 ELECTRIC DATA MIN. CIRC. AMPACITY 48.5 MAX. CIRC. PROTECTION 50 UNIT NUMBER / (QUANTITY) CU-1 I 1 E-o MANUFACTURER PAYNE .... MODEL PA16NA03000G z NOMINAL TONS 2.5 t.!l VOLTAGE 240-1-60 z WEIGHT (LBS.) .... 171 rn COf.IPRESSOR R.LA / LR.A. 12.8 I 64 z r:.::l CONDENSER FAN MOTOR 1/10 PSC z FUSE OR HACR MINIMUM 16.8 0 BREAKER MAXIf.IUM 25 u REFRIG. LINES * LIQ. I SUCT. 3/8 I 3/4 REFRIGERANT R-41 OA (PURON} NOTE: REQUIRE PROGRAMf.IABLE THERMOSTAT, SEE ENERGY CALCULATIONS & DRAWINGS. REFRIGERANT LINES SHALL BE TYPE "L" SEAMLESS COPPER. INSULATE SUCTION LINE WITH ARMAFLEX 3/4" ABOVE 50' USE MANUFACTURER'S CAPACITY f.IULnPLIERS AND BALANCE LINE SIZING INSTRUCTIONS. TO SUBsnTUTE AND INSTALL ANY OTHER SIMILAR OR EQUAL A/C SYSTEM, DIFFERENT FROM THE ABOVE SHOWN, CHECK & MATCH CALCULAnONS SEER, SENSIBLE COOLING CAPACITY AND All REQUIREMENTS AS PER CHAPTER 13 F. B.C. M1411 6 LOCKING ACCESS PORT CAPS REFRIGERANT CIRCUIT ACCESS PORTS LOCATED OUTDOORS SHALL BE FITTED WITH LOCKING-TYPE TAMPER-RESISTANT CAPS. PROVIDE PROGRAMMABLE THERMOSTAT TO THIS A.H.U. (SEE ENERGY CALCULAnONS). CLOSET CEILING BE AIRnGHT -----YI FLEXIBLE SUPPLY DUCT I I CEILING PERFORATED CAP 12" ABV. DRAIN PAN '--PLENUM SHALL BE MECHANICALLY ATTACHED AUX, OVERFLOW LINE W/ FLOAT SWITCH(SEE DETAIL) 3/4" C.D. AND PIT TR.'ii'-- WITH C.O. BY PLUMBER ISOMODE PADS----- METAL SUPPORTS ---- 12' HIN. lUIDEf<! TI-IAN I '--RU(II REFRIG. IN AmC SPACE TO COND. UNIT INSULATE WALLS R-1 2" PVC COND. DRAIN LINE . DISCHARGE 6"ABOVE FINISH GRADE TYPICAL AIR HANDLING UNIT MOUNTING DETAIL N.T.S. CONSTRUCT AND SEAL A/C SYSTEI.l COMPONENTS IN ACCORDANCE WITH FBC CHAPTER 13. CONDENSATE LINE UNDERGROUND TO BE 2" MINIMUM, PVC SCHEDULE 40. 141305 1 1 FURNACES AND AIR HANDLERS FURNACES AND AIR HANDLERS WITHIN COMPARTMENTS OR ALCOVES SHALL HAVE A l.liNIMUM WORKING SPACE CLEARANCE OF 4 INCHES (102 MM) ALONG THE SIDES, BACK AND TOP WITH A TOTAL WIDTH OF THE ENCLOSING SPACE BEING AT LEAST 12 INCHES (305 MM) WIDER THAN THE FURNACE OR AIR HANDLER. FURNACES HAVING A FIREBOX OPEN TO THE ATMOSPHERE SHALL HAVE AT LEAST A 6-INCH (152 MM) WORKING SPACE ALONG THE FRONT COMBUsnON CHAMBER SIDE. COMBUsnON AIR OPEtliNGS AT THE REAR OR SIDE OF THE COMPARTMENT SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 17. DIFFUS W/VP BUILT-IN (SEE PLAN VIEW) '----Sr.ll. JOINT WITH EPO)(Y AND DUCT TAPE TYP. F'LEXIBLE DUCT CONNECTION DETAIL N.T.S, ·= 1 1/2' HNIGER B'\ND CLAMP WITH WIRE IS OPIIONAI.. TYPICAL FLEXIBLE DUCT SUPPORT ROOF STRUCTURE SEE ARCHITECTURAL I 4-16d NAILS---7" THRU PLYWOOD DAMPER DuCT FROM UNIT-Ill (SEE PLAN FOR SIZE 8c TYPE) N.T.S. PROVIDE W/P. CAP LOW PROFILE B.D.D. AT TOP. PROVIDE CORROSION RESISTANT BIRO SCREEN FOR BATHROOM CAPS ONLY & NO BIRD SCREEN FOR DRYER CAP. ..... 6 "CLEAR FROM FINISH ROOF. TYPICAL ROOF' CAP DETAIL @ DRYER AND/OR TOILET EXH. N.T.S. CLOTHES EXH. DRYER DUCT SHALL NOT BE SCREENED ( 4. MIN) & CONSTRUCTED OF A MIN. O.D16 INCHES THICI< OR 26 GAUGE METAL PIPE HAVING A SMOOTH INTERIOR SURFACE W/ JOINTS IN THE DIRECTION OF THE AIR FILOW NO SCREWS OR FASnENERS EXnENDED INTO THE DUCTS AS PER FMCR-MI502.4.1 BATHROOM EXHAUST DUCTS TO BE CONSTRUCTED OF A MIN. 30 GAUGE (GALVANIZED) OR 26 GAUGE (ALUMINUM) AND DISCHARGE TO THE OUTSIDE OF THE BLDG. SHALL BE TERMINATED NOT LESS THAN 6" ABOVE THE FINISHED ROOF SURFACE AND SHALL BE SCREENED WITH A CORROSION RESISTANT MATERIAL, MESH SIZE NOT LARGER THAN 1/2". A/C AREA ___ 1,505 SQ. FT. HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR FIRE DAf.IPER(S) SMOKE DAMPER(S) nRE RATED ENCLOSURE FIRE RATED ROOF CEILING ASSEMBLY FIRE SlOPING SMOKE CONTROL FLORIDA BUILDING CODE SECTION 4901.4(C) EXCEPTON GROUP I ONLY :::::> = u if). z < FAN NO. MANUFACTURER MODEL C.F.M. S.P. R.P.M. VOLTAGE AMPS/ WATTS DRIVE SERVICE LOCAnON SONES / DUCT ACCESSORIES REMARK GREAT ROOcf 2" U.G. CD UNE 10x8 3W-C.G. 175 CFM E.F. - 1 GREEN HECK SP - B50 50 C.F.I.l. 0.125 • 625 120 VOLTS 0.50 I 37.8 DIRECT BATHROOMS CEILING 1.4 I 4"• ROOF/ WAILL CAP ENERGY STAR QUALIFIED 8x6 1W-C.G. 75 CFM ENTR'f VENnLAnON CALCULAnONS (CFM) REQUIRED PROVIDED f.IASTER BATH (TOILET RM) 50 CFf.l 50 CFf.l BATHROOM (TOILET) 50 CFf.l 50 CFf.l NOTES IT IS THE INTENT OF THESE PLANS TO PROVIDE A COI.lPLETE OPERAnNG SYSTEM. A/C CONTRACTOR SHALL FURNISH AND INSTAll. All. REQUIRED EQUIPMENTS, ETC., EXCEPT WHERE SPECIFICAI.l.Y NOTED AS BEING FURNISHED BY OTHERS. SHOULD THERE BE ANY QUESTIONS CONCERNING RESPONSIBILITY, THEY SHALL BE SETTLED BEFORE BID SUBI.liSSION AND CONTRACT SIGNING.- NO EXTRA CHARGES WILL BE Al.l.OWIED. W.I.C. ' I I I I __ _j u p --- riASTER BEDR00'1 1" U.D. (typ.for bedrooms) , I 12x12 R.A.G. b I -"- _/ I L .. _- -.'cJ / ( I BEDROOc1 '2 1" U.D. (typ.for bedrooms) 1" U.D. (typ.for bedrooms) BATH "·' BEDRO:A-1 '3 10x8 1W-C.G. 140 CFM REF. LINES IN AmC l ---------- -- ------ REFRIGERANT SUCTION LINE LINES TO BE INSULATED WITH INSULATION HAVING A THERMAL RESisnVITY OF AT LEAST R-4 AND HAVING AN EXTERNAL PERMEANCE NOT EXCEEDING 0.05 PERM WHEN TESTED IN ACCORDANCE WITH ASTM E 96. ,------------------------- l I I I I 1 Twa :::ARS 1 I GARAGE I I I I I I I r I I ; I I 1 -- 1 I I I PLAN 1/4'•1'-IZ>' I . CONC. SLAB FeEVISIONS 6'Y' "<[ "' ill - illo "<[ -' "'- 1<\.J:) "'.J:) 0 t- ·-ill \)QE - -"'o OCu ' u ::::l "' ·-u.. u t- r:.J:)!J :5 .J:){j .J:) 6«)"- .-- <l:l., <O•o ill- d) Q .J:>S - ol <::: W--..'ll "<[ ...I a. :J<I:l(l au <flo ,ill .. "Cl .J:)= 'll.J:)'Il () E oc-OJ ill "<[<( "ClQ ('{) t- N .. l) 0 0.. w () Zl- <(Z zw (911.. <( z9 0 -w 0:: (f)> 0 ...J =>w lL Oo >- I f- >->- z ::J 1-1- 0 zz (.) 0 ::::>::::> 0:: 0 oo 0:: o:::o DO 0::: w z O<( s 0::: 0 (() :;;: A-ll 0 0 0:: A-ll f-w A-ll <('-' w<t: 0::0:: '-'..: (f) C) 21/l 00:: IN A !;;:oil DOZ Nw C) .I 1/l(.) 2f- 11 0>2 0 ..,.., 0:: ,-o 0 w DO "' T!-115 DF::ALUING AN::> SFECIFI:::::ATIONS CO"'TAINS AND ARE TI-l=: PRo=:::Rrr CF OCTAVIO A 5ANTURIO AIA.FA AND MAY NOT eE REPRODUCED, COPIED OR DISTRBUTED WITI-OUT TI-l:::: EXPRESSED WRITTE\1 FERYI&5ION AND COMFENSA TICN OF OCTAVIO ,C._ SANT-RIO AlA_ =A DRAW>, JOf.lN D. C-IECKED OAS. ::>ATE JANUARY 212'1"' SCALE AS Sf.IOWN JOB NO I"'IZ'S 51-!EET AC-1 I OF 1 5f.IEET5
4

Model 3 MEP · 2015. 2. 11. · 3/4 refrigerant r-41 oa (puron} note: require programf.iable thermostat, see energy calculations & drawings. refrigerant lines shall be type "l" seamless

Oct 03, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Model 3 MEP · 2015. 2. 11. · 3/4 refrigerant r-41 oa (puron} note: require programf.iable thermostat, see energy calculations & drawings. refrigerant lines shall be type "l" seamless

AIR CONDITIONING NOTES

1bullshy AC CONTRACTOR SHALL

A) VERIFY All SPACE CONDillONS AND DIMENSIONS AT JOB SITE PRIOR THE CONSTRUCTION OF DUCTWORK AND INSTALlATION OF ANY EQUIPMENTS

B) COORDINATE ALL WORK WITH OTHER TRADES (REVIEW ALL PLANS)

C) DO All WORK IN ACCORDANCE WITH STATE AND LOCAL CODES

D) DO ALL WORK IN ACCORDANCE WITH LATEST ASHRAE GUIDE AND SMACNA STANDARDS COMPLY WITH ALL RECOMMENDATIONS AND INSTRUCTIONS OF SMACNA STANDARDS AND THE EQUIPMENTS MANUFACTURERS

E) ADJUST AND BALANCE DIFFUSERS IN ACCORDANCE WITH QUANTITIES SHOWN ON PLANS (LATESTS NAnONAL ENVIRONMENTAL BALANCING BUREAU PROCEDUAL STANDARDS OR AABC NAnONAL STANDARDS

F) SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL

2- GUARANnEES

A) All NEW EQUIPMENTS PARTS AND MATERIALS SHALL BE GUARANnEED FOR ONE YEAR AFnER DATE OF ACCEPTANCE

B) PROVIDE 90 DAYS FREE SERVICE

3- TYPICAL AIR CONDITIONIND DUCTWORK (READ NOTES

A) SHALL BE CONSTRUCTED OF STANDARD DUTY FIBERGLASS BOARD FLAMEshy PROOF REINFORCED ALUMINUM FACED COVER IN ACCORDANCE WITH FBC AND NFIPA LATEST GUIDES AS MANUFACTURED BY OWENS-CORNING INSTALL AIR VOLUME EXTRACTORS TURNING VANES OR AIR SCOOPS AT EACH DUCT TAP FIBERGLASS DUCT BOARD R VALUE TO BE MINIMUM 42 AT COND SPACES AND 60 AT NON CONDillONED SPACES SUCH AS ATTICS

B) All DUCTWORK SHALL BE CONSTRUCTED AND ERECTED IN ACCORDANCE WITH THE PROVISIONS OF THE LATEST nMA CONSTRUCTION STANDARDS AND AS PER FBC-CHAPTER 6 - SECTION 603

4- EXHAUST OR VENnLAnON DUCTWORK

A) SHALL BE CONSTRUCTED AS PER FBC-CHAPTER 5 FROM GALVANIZED SHEET METAL IN ACCORDANCE WITH ASHRAE AND SMACNA STANDARDS TERMINATED OUTSIDE THE BLDG AND EQUIPPED WITH A BACKDRAFT DAMPER (THERMOFIN ALLOWED)

B) CLOTHES EXH DRYER DUCT SHALL NOT BE SCREENED (4 MIN) 8c CONSTRUCTED OF A MIN 001 6 INCHES THICK OR 26 GAUGE METAL PIPE HAVING A SMOOTH INTERIOR SURFACE WI JOINTS IN THE DIRECTION OF THE AIR FILOW NO SCREWS OR FASnENERS EXnENDED INTO THE DUCTS AS PER FMCR-M15024 1

C) BATHROOM EXHAUST DUCTS TO BE CONSTRUCTED OF A MIN 30 GAUGE (GALVANIZED) OR 26 GAUGE (ALUMINUM AND DISCHARGE TO THE OUTSIDE OF THE BLDG SHALL BE TERMINATED NOT LESS THAN 6 ABOVE THE FINISHED ROOF SURFACE AND SHALL BE SCREENED WITH A CORROSION RESISTANT MATERIAL MESH SIZE NOT LARGER THAN 12 (GOOSENECK OR RAIN CAP ON ROOF TERMINAnON)

D) A UL CERTIFIED RESIDENTIAL RECIRCULAnNG KITCHEN EXHAUST HOOD SHALL BE INSTALLED AT KITCHEN

NOnE

AI IPERFORATED VENT CAP

12MIN UNION

SLOPE 18 FT f- AIC UNIT

ll I [ J I DRAIN PAN

314 MIN_ fshy fshy -shy

_3MIN

CONDENSATE DRAIN TRAP DETAIL

FLOAT SWITCH TO SHUT-DOWN EQUIP AS PER FMC 30113 (EZ-TRAP SERIES 200) INSTALLED INSIDE OF DRAIN PAN FBC R-M 1411311

REMOVABLE CAP

~C OVERFILOWI RAIN LINE

NTS

34 AC UNIT DRAIN PAN

DRAIN LINE

AUX OVERFLOW DRAIN LINE DETAIL NTS

STEEL CAGE WACCESS DOOR FOR SECURITY OF AC COMPRESSOR

I II COND UNIT TO BE AT OR ABOVE FLOOR

I I Ill

Ill UEVELf GALVANIZED

---------- bull middotmiddotmiddotLImiddotNE COVER CBS WALL

BOLT CONDENSING UNIT TO f- f middotSUPPORTS TO WITHSTAND _____ c-j 170 MPH HURRICANE ~ 1

FORCE WINOS AS PER I I L FcBcCcbull2010______ ---shy --+-11-tl

I II 12 MIN 4 CONCRETE PAO (SEE ELEVATION ON SITE PLAN)

FINISHED GRADE

NOTE

I

I

CONDENSING UNIT SHALL BE ANCHORED TO THE CONCRETE SLAB ON THE INSIDE OF THE UNIT WrlH (1) 12f SUP-R-STUD (4 12 MIN EMBEDMENT) PER EACH CORNER (1YPICAL)NOA 10-0928-01 EXP 03-03-2016 (SEE CALCULAnONS ATIACHED)

EFRIGERANT NES-

FINISHED FLOOR

TYPICAL CONDENSING UNIT MOUNTING DETAIL NTS

UNIT NUMBER QUANTITY AHU-1 I 1

MANUFACTURER PAYNE

MODEL PF4MNB037TOO E-o NOM TONS 25z

TOTAL CAPACITY SENSIBLE 288oo 1 2o6oo~

tl TOTAL CFM 1000

z S E E R 160

~ WEIGHT (LBS) 157 ~ z VOLTAGE 240-1-60

lt MOTOR TYPE X-13= FAN MOTOR HP I FLA 12 I 41

~ KW BTUH 8o Ilt HEATER 27304

ELECTRIC DATA MIN CIRC AMPACITY 485

MAX CIRC PROTECTION 50

UNIT NUMBER (QUANTITY) CU-1 I 1

E-o MANUFACTURER PAYNE MODEL PA16NA03000Gz

~ NOMINAL TONS 25

tl VOLTAGE 240-1-60

z WEIGHT (LBS) 171

rn COfIPRESSOR RLA LRA 128 I 64z rl CONDENSER FAN MOTOR 110 PSC ~ z FUSE OR HACR MINIMUM 168

0 BREAKER MAXIfIUM 25u REFRIG LINES LIQ I SUCT 38 I 34

REFRIGERANT R-41 OA (PURON

NOTE

REQUIRE PROGRAMfIABLE THERMOSTAT SEE ENERGY CALCULATIONS amp DRAWINGS REFRIGERANT LINES SHALL BE TYPE L SEAMLESS COPPER INSULATE SUCTION LINE WITH ARMAFLEX 34 bull ABOVE 50 USE MANUFACTURERS CAPACITY fIULnPLIERS AND BALANCE LINE SIZING INSTRUCTIONS TO SUBsnTUTE AND INSTALL ANY OTHER SIMILAR OR EQUAL AC SYSTEM DIFFERENT FROM THE ABOVE SHOWN CHECK amp MATCH CALCULAnONS SEER SENSIBLE COOLING CAPACITY AND All REQUIREMENTS AS PER CHAPTER 13 FBC

M1411 6 LOCKING ACCESS PORT CAPS REFRIGERANT CIRCUIT ACCESS PORTS LOCATED OUTDOORS SHALL BE FITTED WITH LOCKING-TYPE TAMPER-RESISTANT CAPS

PROVIDE PROGRAMMABLE THERMOSTAT TO THIS AHU (SEE ENERGY CALCULAnONS)

CLOSET CEILING BE AIRnGHT -----YI

FLEXIBLE SUPPLY DUCT

I I CEILING

PERFORATED CAP 12 ABV DRAIN PAN --~f-1

--PLENUM SHALL BE MECHANICALLY ATTACHED

AUX OVERFLOW LINE W FLOAT SWITCH(SEE DETAIL)

34 CD AND PIT TRii-shyWITH CO BY PLUMBER

ISOMODE PADS----shy

METAL SUPPORTS ---shy

12 HIN lUIDEflt TI-IAN I

--RU(II REFRIG IN AmC

SPACE TO COND UNIT

INSULATE WALLS R-1

2 PVC COND DRAIN LINE ~=====r--2CD DISCHARGE6ABOVE FINISH GRADE

TYPICAL AIR HANDLING UNIT MOUNTING DETAIL NTS

CONSTRUCT AND SEAL AC SYSTEIl COMPONENTS IN ACCORDANCE WITH FBC CHAPTER 13

CONDENSATE LINE UNDERGROUND TO BE 2 MINIMUM PVC SCHEDULE 40

141305 1 1 FURNACES AND AIR HANDLERS

FURNACES AND AIR HANDLERS WITHIN COMPARTMENTS OR ALCOVES SHALL HAVE A lliNIMUM WORKING SPACE CLEARANCE OF 4 INCHES (102 MM) ALONG THE SIDES BACK AND TOP WITH A TOTAL WIDTH OF THE ENCLOSING SPACE BEING AT LEAST 12 INCHES (305 MM) WIDER THAN THE FURNACE OR AIR HANDLER FURNACES HAVING A FIREBOX OPEN TO THE ATMOSPHERE SHALL HAVE AT LEAST A 6-INCH (152 MM) WORKING SPACE ALONG THE FRONT COMBUsnON CHAMBER SIDE COMBUsnON AIR OPEtliNGS AT THE REAR OR SIDE OF THE COMPARTMENT SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 17

DIFFUS WVP BUILT-IN

~DUCT (SEE PLAN VIEW)

----Srll JOINT WITH EPO)(Y AND DUCT TAPE

TYP FLEXIBLE DUCT CONNECTION DETAIL NTS

middot=1 12 HNIGER BND CLAMP WITH WIRE IS OPIIONAI

TYPICAL FLEXIBLE DUCT SUPPORT

ROOF STRUCTURE SEE ARCHITECTURAL

I 4-16d NAILS---7 THRU PLYWOOD

BACKDRAFT----~-~ DAMPER

DuCT FROM UNIT-Ill(SEE PLAN FOR SIZE 8c TYPE)

NTS

PROVIDE WP CAP LOW PROFILE BDD AT TOP PROVIDE CORROSION RESISTANT BIRO SCREEN FOR BATHROOM CAPS ONLY amp NO BIRD SCREEN FOR DRYER CAP

6 CLEAR FROM FINISH ROOF

TYPICAL ROOF CAP DETAIL DRYER ANDOR TOILET EXH

NTS

CLOTHES EXH DRYER DUCT SHALL NOT BE SCREENED (4 MIN) amp CONSTRUCTED OF A MIN OD16 INCHES THICIlt OR 26 GAUGE METAL PIPE HAVING A SMOOTH INTERIOR SURFACE W JOINTS IN THE DIRECTION OF THE AIR FILOW NO SCREWS OR FASnENERS EXnENDED INTO THE DUCTS AS PER FMCR-MI50241

BATHROOM EXHAUST DUCTS TO BE CONSTRUCTED OF A MIN 30 GAUGE (GALVANIZED) OR 26 GAUGE (ALUMINUM) AND DISCHARGE TO THE OUTSIDE OF THE BLDG SHALL BE TERMINATED NOT LESS THAN 6 ABOVE THE FINISHED ROOF SURFACE AND SHALL BE SCREENED WITH A CORROSION RESISTANT MATERIAL MESH SIZE NOT LARGER THAN 12

AC AREA ___1505 SQ FT

HVAC DESIGN REQUIRES YES NO

DUCT SMOKE DETECTOR FIRE DAfIPER(S) SMOKE DAMPER(S)

nRE RATED ENCLOSURE FIRE RATED ROOF CEILING ASSEMBLY FIRE SlOPING SMOKE CONTROL

FLORIDA BUILDING CODE SECTION 49014(C) EXCEPTON GROUP I ONLY

~ ~ gt ~ ~ = u if)

z lt ~

FAN NO

MANUFACTURER

MODEL

CFM

SP

RPM

VOLTAGE

AMPS WATTS

DRIVE

SERVICE

LOCAnON

SONES DUCT

ACCESSORIES

REMARK

GREAT ROOcf

2 UG CD UNE

10x8 3W-CG 175 CFM

EF - 1

GREEN HECK

SP - B50

50 CFIl

0125 bull

625

120 VOLTS

050 I 378

DIRECT

BATHROOMS

CEILING

14 I 4bull

ROOF WAILL CAP

ENERGY STAR QUALIFIED

8x6 1W-CG 75 CFM

ENTRf

VENnLAnON CALCULAnONS (CFM) REQUIRED PROVIDED

fIASTER BATH (TOILET RM) 50 CFfl 50 CFfl

BATHROOM (TOILET) 50 CFfl 50 CFfl

NOTES IT IS THE INTENT OF THESE PLANS TO PROVIDE A COIlPLETE OPERAnNG SYSTEM AC CONTRACTOR SHALL FURNISH AND INSTAll All REQUIRED EQUIPMENTS MATER~ ETC EXCEPT WHERE SPECIFICAIlY NOTED AS BEING FURNISHED BY OTHERS SHOULD THERE BE ANY QUESTIONS CONCERNING RESPONSIBILITY THEY SHALL BE SETTLED BEFORE BID SUBIliSSION AND CONTRACT SIGNINGshy NO EXTRA CHARGES WILL BE AllOWIED

WIC

I

I

I

I

__ _j

u p

--shy

riASTER BEDR001

1 UD (typfor

bedrooms)

10)~--[SJ I

~~ 12x12 RAG

b

I -- _ I

L _- -cJ

(

I ~

BEDROOc1 2

1 UD (typfor

bedrooms)

1 UD (typfor

bedrooms)

BATH middot

BEDROA-1 3

10x8 1W-CG 140 CFM

REF LINES IN AmC

l

---------shy -shy -----shy

REFRIGERANT SUCTION LINE LINES TO BE INSULATED WITH INSULATION HAVING A THERMAL RESisnVITY OF AT LEAST R-4 AND HAVING AN EXTERNAL PERMEANCE NOT EXCEEDING 005 PERM WHEN TESTED IN ACCORDANCE WITH ASTM E 96------------------------- l I I I I 1

Twa ARS 1

I GARAGE I

I I I I I I r I I I I 1-shy1 I I I

MEC~ANICAL PLAN 14bull1-IZgt

I

CONC SLAB

FeEVISIONS 6Y

bulllt[

bull ill cent- bull illo

lt[ -shy1ltJ) J)

0 Cl~

tshy middot-ill )QE- -o

OCu a~ u EX~

l ~middot-u u

t- w~ rJ)J 5 J)j

~ J) 6laquo)shy-shy ltll

~---~ ltObulloill-

d) Q bull JgtS- J)~

ol lt W--ll

bull t~ lt~lt[ QJcent~I ~lt0pound0a

JltIl(l

au ltfloill

Cl J)=llJ)Il

gt~ () Eoc-OJill

lt[lt( ClQ -~ () [)~

t- N

l) J)~ ~ll

0 0

w ()Zlshylt(Zzw Ll~ (911 lt(

z9 0

-w 0(f)gt 0

J=gtw lL

Oo gtshyI fshy

gt-gtshy z J

1-1shy 0 zz ()

0 gtgt 0 0~ ~ ()~ 0 oo 0

oo DO

0 ~~ w z Olt(s 0 0 (()

A-ll 0 0 0

A-ll f-w

A-ll lt(-wltt 00

~ - (f) C) 21l00

~ ~li IN

A oil DOZ Nw

C) I 1l()2fshy

11 0gt2 0 0 -o 0 w DO

T-115 DFALUING ANgt SFECIFIATIONS COTAINS PROPRE-A~Y 11-FO~_ATION

AND ARE TI-l= PRo=Rrr CF OCTAVIO A 5ANTURIO AIAFA AND MAY NOT eE REPRODUCED COPIED OR DISTRBUTED WITI-OUT TI-l EXPRESSED WRITTE1 FERYIamp5ION AND COMFENSA TICN OF OCTAVIO C_ SANT-RIO AlA_ =A

DRAWgt

JOflN D C-IECKED

OAS gtATE

JANUARY 2121 SCALE

AS SfIOWN JOB NO

IIZS

51-EET

AC-1 I OF 1 5fIEET5

--

----

--

PLUMBING LEGEND

WH WATER HEATER SOIL OR WASTE UNE

co CLIEANOUT ---- shy VENT LINE

~VISIONS BY

GENERAL PLUMBING NOTES

1 ALL WORK SHALL CONFORM WITH ALL LOCAL STATE FEDERAL ORDINANCES AND BUILDING CODES GOVERNING THE INSTALLATION OF THE PLUMBING SYSTEM IF WORK AS LAID OUT INDICAnED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES BUILDING CODES AND REGULATIONS THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECTENGINEER BEFORE SUBMITTING A BID THE ARCHinECTENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED

2 THE DRAWINGS ARE TO BE CONSIDERED DIAGRAtAMATIC NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS UNUESS SPECIFIC DIMENSIONS ARE SHOWN THE STRUCTURAL ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXItAUtA HEAD ROOM AND SPACE CONDITIONS AT ALL POINTS WHERE HEAD ROOM OR SPACE CONDITIONS APPEAR INADEQUAnE ARCHITECTENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION THIS CONTRACTOR SHALL WITHOUT EXTRA CHARGE MAKE FIELD MODIFICATIONS IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK

3 EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBtAITTING A BID CONTRACTOR WILL BE REQUIRED TO FURNISH INSTALL ANDOR CONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEtAS SHOWN ON ANY OF THE ARCHinECTURAL AIR CONDITIONING ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPENshySE TO THE OWNER IF DISCREPANCIES CONFLICTS INTERFERENCES OR OMISSIONS OCCUR BETWEEN DRAWINGS NOTIFY IN WRITING THE ARCHinECTENGINEER IN AMPLE TltAE TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED

4 INSTALL MAnERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS OF WHICH IN HIS OPINION DO NOT PRESENT A NEAT AND WORKMANLIKE APPEARANCE REMOVAL AND REPLACEMENT IS TO BE DONE IMMEDIAnELY WHEN DIRECTIED BY THE OWNER IN WRITING AT THE SOLE EXPENSE OF THE CONTRACTOR

5 START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER CONTRACTORS TO RECEIVE HIS WORK THIS CONTRACTshyTOR SHALL REtAOVE AND REPLACE AT HIS EXPENSE ALL PLUMBING WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCES WITH OTHER TRADES

6 THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE FEES PERMITS ASSOCIATION DUES ROYALTIES AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK HE SHALL ALSO PAY ALL INSPECTION FEES AS MAY BE REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS RUUES OR ORDINANCES

7 PROVIDE MEANS FURNISHED AND INSTALL

8 DO A COMPLETE JOB EVERYTHING CONNECTIED READY FOR USE

9 SHOP DRAWINGS THIS CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL

1 0 AT COMPLIETION OF JOB THE PLUMBING CONTRACTOR SHALL GIVE THE OWNER AN AS-BUILT SET OF REPRODUCIBUE SEPIAS SHOWING THE EXACT INSTALLATION

11 PLUMBING CONTRACTOR SHALL PRESSURE nEST ALL PIPING AS REQUIRED BY CODE TEST SHALL BE WITNESSED AND APPROVED BY PROPER AUTHORITIES

12 THE PLUMBING CONTRACTOR SHALL WARRANT ALL WORKtAANSHIP AND MATERIALS FOR ONE YEAR FROM THE DAnE OF FINAL WORK ACCEPTANCE BY OWNER ANY BREAKDOWN OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE TO THE OWNER

13 PLUMBING FIXTURES SPECIFICATIONS TO BE SUBMITTED BY ARCHinECT AT A LAnER DAnE

14 PROVIDE SHUT-OFF VALVE FOR EACH FIXTURE

1 5 WHEREVER DISSIMILAR METALS ARE TO JOINED A DI-ELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES

16 PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING CONDENSATE DRAIN AND TRAP SEE AIR CONDITIONING PLANS FOR LOCATION OF UNITS AND DRAINS

17 MATERIALSmiddot

A COLD amp HOT WATER PIPING DOWNSTREAM OF WATER METER SHALL BE CPVC

B SANITARY WASTE AND VENT LINES SHALL BE PVC

C CONDENSAnE DRAIN PIPE SHALL BE INSULAnED PVC SCHEDULE 40

v VENT COLD WATER LINE

VTR VENT-THRU-ROOF --middot-- HOT WATER UNE

IAS-R BEDRCOI1

I I

( TUB

ll~~~I I =

(5 ru) JAll

rmiddot )ii1 k--

~

~ 2

Qr I

[--1 2cw ampCD CONDENSATE DRAIN 12HW ONw WASTE

cw COLD WATER 12 HB WVACUUM BREAKER -2 VENTamp VALVE ON RAISER+FCO FLUSH CLIEANOUT -M-- GATE VALVEFU FIXTURE UNITS _

RVD RELIEF VALVE DISCHARGE PIPING TURN DOWN

CD CONDENSATE DRAIN 0 PIPING TURN DOWN

---o PIPING TURN UPJl~ VTR (VENT THRU ROOF) -o- PIPING TURN UP

3 (5 FU)

rr~~~~~12 HB WVACUU~

~---------~ BREAKER amp VALVE I 0sectshyON RISER- 1 I I

I me II

EEDROOHl______ r ~

I -12CW DN plusmn== c

I I I I

- ALL SANITARY PIPING 2 OR LESS TO HAVE 14 MIN SLOPE

3 I I - ALL SANITARY PIPING 3 TO 6 TO HAVE 18 MIN SLOPE (5 FU)

- ALL SANITARY PIPING 8 OR LARGER TO HAVE 116 MIN SLOPE KITCI-Et~

-PROVIDE ANTI-SCALDING VALVE IIOF ON ALL TUBS AND SHOWERS

-PROVIDE SHUTOFF VALVE FOR EACH FIXTURE

- PROVIDE CLEAN OUTS AT EACH SOIL B WASTE STACKS

2VTR~W FOOD GRINDER

BEDROOMGREAT ROOcl S

bull ~ - nshy

bull nrshylt - shy-~ 0

11~

I shy middot-n Cl~E- LL~OOCo middot- 4 EXlaquogt

l middot-lL 0

t- w~ I Ill cpound)~

~ ~c- gt 0 r- Oui~

~---~ o ~ ol) middot shy

d) ~ ~s- oi s

w~bull I~ rlt1-

lt Ill ltI)--1 ~()pound01L gtltIll)

au ltI)bullol) bullbull

11 -= -~$it 0 E rt----~

ol)

ltlt 11~ ~(() ru~

tshy 0 -~

0-Ie

0 Q_

w 0Zlshylt(Zzw LL2 C) a

(sectz9 -w It(fJgt 0

__jJw lL

Oo ~I gt-gtshy z

J 1-1shy 0 zz ()

0JJ It 02 ~ 02 0 oo It

oO Ill

~~0 w z Olt(

s 0 0 Ill

jiijl 0 0 Itjiijl f--w

jiijl lt(()

tljJi

~ ()lt( (J)()(f)Ott

~ 0lt(ttU IN

A f-oeslt( lllZNw

0 -I (J)()f-shy0lt11 0

~ It

-o 0 w Ill ()

TI-llS D~AWINC AND SPECIFICATIONS CCNTAINS PROPRIETARY INFOR-JATION A~D A~ TI-lE =~OFE~TI OF OCTAVIO A 3ANTURIJ AIAPA AlD MAY OT BE R~f-ROP~CI~ COF-IP OFlt PIS-RI6UTED wr--lOUT TI-lE EXPRESSED WRnEN PERM ISS ON AND C01PEI-SATION CF OCTAVIO A SANTURIO AlA FA

FIXTURE CONNECTION SCHEDULE

ITEM cw CONN

HW CONN

TRAP SIZE

FU COUNT REMARKS

LAVATORY 12 12 1 14 1 BIDET 12 12 2 2 WATER CLOSET (TANK) 12 - 3 4 SHOWER 12 12 2 2 WANTI-SCALD ttiXING VALVE BATHTUB 12 12 2 2 WANTI-SCALD VALVE

BATH GROUP 5 FU

KITCHEN SINK 12 12 1 12 2

DISHWASHER - 12 1 12 2 WASHING MACHINE 12 12 2 2

HOSE BIB 12 - - - VACUUM BREAKER amp VALVE IN THE VERTICAL

6049 WAlER ]H_E FLOW VELOCITY OF THE WATER DISTRIBUTION SYSIDt SIWL BE CONTROLLED TO REDUCE ]HE middot laquo_WATER_ HAMMER A WATER-twIIER ARRESTOR SHALL BE INSTAllED WHERE QUICK-CLOSING VALVES ARE UTILIZED WAlER HAMMER ARRESTORS SHALL BE INSTAllED IN ACCORDANCE WITH THE IIANlFACTIJRERS SPECIFICATIONS WAlER HAMMER ARRESTORS SIWL CONFORM TO ASSE 1010

12 MIN 3 I

2 UG CD LINE ~~~I bull ~~~~~V~RADE 34 UG RVD LINE

bull 1~3H RVD Ill IE-__JII~ ~~L -pound_

TO OUTSIDE amp TERMINATE 6 ABOVE RNISH ~ ---~~ct~t~ V 1_1

middot~

GRADE 3 I )(14 FU)

-J 1 ------------------34CW---------------~THE DISCHARGE PIPE SHALL I 34CWNOT HAVE ANY TRAPPED

--------------------------lI 34 CW ON_VISIBLE AIR GAP OR AIR GAP SECTIONS AND SHALL HAVE A

I TO EWH tWo CARS I FITTING LOCATED IN THE SAME GARAGE ~

IROOM AS THE WATER HEATER MASTER WATER AS PER P2803_6 1_1 FB_C I SHUT-OFF VALVE

I- IN CONC BOXI

I I 1ishyI I - ~~~ ~~~2 WAY C~ I 34CW

TABLE P29032a FCO ~ AIMAXIMUM FLOW RATES AND CONSUMPTION FOR I ~--------------~ PLUMBING FIXTURES FIXTURES FITIINGS AND APPLIANCES I

PLU~tBING FIXTURE PLUMBING FIXTURE OR OR

FIXTURE FITIING FIXTURE FITIING

LAVATORY FAUCET 15 GPM AT 60 PSI

SHOWER HEADa 15 GPM AT 80 PSI

SINK FAUCET 15 GPM AT 60 PSI

WATER CLOSET 128 GALLONS PER FLUSHING CYCLE

DISHWASHER 65 GALLONS PER CYCLE OR LESS

WASH MACHINE WATER FACTOR OF 8 OR LOWER

I I I I I

I

3 (14 FU) 12 HB WVACUUM _J

I BREAKER amp VALVE ON RISER

~34CW I

1

3 (14 FU) -SANITARY LINE 34 WATER SERVICE CONNECTED CONNECTED TO SEWER MAIN SERVICE TO WATER METER BY UTILnY CO BEFORE INSTALLATION COORDINATE BEFORE INSTALLATION COORDINATE EXACT LOCATION AT FIELD EXACT LOCATION AT FIELD SEE SITE PLAN FOR CONTINUATION SEE SITE PLAN FOR CONTINUATION

I 7-12

-

I I I I I I

Ht-57-sectI I

~

__----PATI-t

I

-

I

I

F ~ iht

11_)CJ=---lt D I I

1-4 2-8 1-4

--

~~-======If

I

_j 1-b L 3-2 1-6 2-8

~ ___J~ 101 l~dmiddot(o~)~~- ()

I itgt ilr~n~ ~lt

~_

I l ~middot-e~middot

I

FOR 51 1 GAIlON PER MtiiTE = 3785 Lrn1 POUND PER SQUARE INCH = 6895 KPa

FIXTURE CLEARENCE FLAN FIXTURE CLEARENCE FLAN Vlt4bull14 a A HANDHELD SHOWER SPRAY IS AlSO A SHOWER HEAD b A CONSUMPilON TOLIRANCES SHAll BE DEIERMINED FROMMASTER 6ATHROOM 6ATH No2 REFERENCED STANDARDS c WATER FICTOR IN GAIIONS PER CYCLE PER CUBIC FOOT PLUMBING PLAN 14=1-IZ

ALL PLUMBING FIXTURE SHALL BE EPA WATER SENSE LABELED

DRAW

JOI-lN D I-IECKEr

OA5 DATE

JANUARY 2015 SCA_E

A5 51-lOWN )06 NO

1505

51-lEET

PL-1 I OF 2 51-lEET5

50 GAL ELECTRICAL

EWH

JJW

i til

o II ) o j middot~I

bullcwl [f-z i cWvmiddotlp

~VISIONS BY

I CW amp HWSERVICE RUN ABOVE CEILING SEE FLOOR PLAN FOR ROUTING

HEAT TRAPmiddot--- MINIMUM 3

DRAIN COCK

34

34

AIR GAP

RVD RISER

_ 34 RVD LINE TO OUTSIDE amp TERMINATE 6 ABOVE GRADE

WAlER HEAlER PIPING DETAIL NTS

WATER HEATER DATA

MARK STORAGE IN US GAL INPUT MANUFACTURER

MODEL No ELECTRICAL

DATA ENERGY

EFFICIENCY

EWH 50 45KW AOSMITH

PROMAX middot ECT-52 OR

EQUAL

24()1-lO 091

WATER HEATER TYPICAL WATER RISER DIAGRAM NT5

2 VTR

T I I jx~v SHUT-OFF VALVE -Jl_

12HB WVACUUM f-CW IN CONC BOXo

BREAKER amp VALVE 1J2 ON RISER

2 VTRgt 2

l----shy~-

34 WATER SERVICE CONNECTED~ bull shyTO WATER METER BY UTIUJY CO BEFORE INSTALLATION COORDINATE _

2EXACT LOCATION AT FIELD bull ( SEE SITE PLAN FOR CONTINUATION

---

3 (14 FU SANITARY LINE CONNECTED TO SEWER MAJN SERVICE BEFORE INSTALLATION COORDINATE EXACT LOCATION AT FIELD SEE SITE PLAN FOR CONTINUATION

TYPICAL SANITARY RISER DIAGRAM Nrs

2 VTR

Ill 1-ill_ I

I tmiddot I I - I-- 2 I I - I 2

II II

2 II I I I I

2

bull ~ onshy- bull onrshy

- 0lt shy-~ 0 I-

11~ middot-U Cl~E -lt) - LL~_ 0 EX d)OCo middot-lL 0l I Ill cpound)~t-- w~ ~c- gt 0 r- Oui~

~---~ ltOoo ~ 1f middot shy

~s ~

~d) oL s

w~bull I~ rlt1-

QJ lt --1 ~()pound01L gtell)

au ltI)bullU

11 -= -~ rt----~$it ) E

1f

~(() ru~ltlt 11~

t-- -~

0 )0 -lc

Q_

w 0Zlshylt(Zzw LL2 C) a

(sect -w z9

It 0(fJgt uJw _j

OoI ~ gt-gt- J

z 1-1- 0 zz ()

JJ 0 It

02 ~ 02 0 Itoo

oO Ill

0 w ~~ z Olt(

0s 0 Ill

0jiijl 0

jiijl It f-wlt(()jiijl tljJi()lt( (J)()(f)~ Ott 0lt(ttU~ IN

A f-oeslt( lllZ

0 NwI

(J)()

11 f shy0lt 0 It~ -o 0 w Ill ()

TI-llS D~AWINC AND SPECIFICATIONS CCNTAINS FROFRIETART INFOR-JATION A~D A~ TI-lE =~OFE~TI OF OCTAVIO A 3ANTURIJ AIAPA AlD MAY OT BE R~f-ROP~C~~ COF-IP OFlt PIS-RI6UTED wr--lOUT TI-lE EXFREOSED WRr-TEN FERMIS6 ON AND C01PEI-6ATION CF OTAVIO A OANTURIO AlA FA

DRAW

JOI-lN D I-IECKEr

OA5 DATE

JANUARY 2015 6CA_E

A5 51-lOWN )06 NO

1505

51-1EET

PL-2 2 OF 2 5HEET5

~VISIONS BY

GENERAL ELECTRICAL NOTES

1 ALL WORK SHALL CONFOR~ WITH ALL LOCAL STAlE FEDERAL ORDINANCES AND BUILDING CODES GOVERNING THE INSTALLATION OF THE ELECTRICAL SYSTE~ IF WORK AS LAID OUT INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES BUILDING CODES AND REGULAshyTIONS THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECT ENGINEER BEFORE SUB~ITTING A BID THE ARCHITECTENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED

2 THE DRAWING ARE TO BE CONSIDERED DIAGRAMMATIC NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE ~INOR ITE~S UNLESS SPECIFIC DI~ENSIONS ARE SHOWN THE STRUCTURAL ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK CHECK DRAWINGS OF ALL TRAIDES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND ~AINTAIN MAXI~U~ HEAD ROO~ OR SPACE CONDITIONS AT ALL POINTS WHERE HEAlD ROO~ OR SPACE CONDITIONS APPEAR INADEQUATE ARCHITECTENGINEERSHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION THIS CONTRACshyTOR SHALL WITHOUT EXTRA CHARGE MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK

3 EXA~INE ALL DRAWINGS CAREFULLY PRIOR TO SUB~ITTING A BID CONTRACTOR WILL BE REQUIRED TO FURNISH INSTALL ANDOR CONNECT WITH APPROPRIATE SERVICES ALL ELECTRICAL ITEMS SHOWN ON ANY OF THE ARCHITECTURAL PLU~BING AIR CONDITIONING SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPENSE TO TIHE OWNER IF DISCREPANCIES CONFLICTS INTERFERENCES OR O~ISSIONS OCCUR BETWEEN DRAWINGS NOTIFY IN WRITING THE ARCHITECT ENGINEER IN AMPLE TI~E TO PER~IT REVISIONS BEFORE TIHE BIDS ARE SUB~ITlED

4 VERIFY SERVICE CHARACTERISTICS LOCATION AND CONNECTION WI1H TELEPHONE AND ELECTRIC UTIUTY CO~PANIES PERFOR~ ALL WORK RELATED TO SERVICE IN STRICT ACCORDANCE WITH UTIUTY Co STANDARDS AND REQUIRE~ENTS

5 INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEshyMENT OF ITEM WHICH IN HIS OPINION DO NOT PRESENT A NEAT AND WORKMANshyLIKE APPEARANCE RE~OVAL AND REPLACEMENT IS TO BE DONE ~~~EDIATELY WHEN DIRECTED BY THE OWNER IN WRITING AT THE SOLE EXPENSE OF CONTRACshyTOR

6 START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER CONTRACTIDRS TO RECEIVE HIS WORK THIS CONTRACTOR SHALL REMOVE AND REPLACE AT HIS EXPENSE ALL ELECTRICAL WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRAIDES

7 THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE FEES PERMITS ASSOshyCIATION DUES ROYALTIES AND TAXES OF WIHATEVER NATURE SHALL APPLY TO THIS WORK HE SHALL ALSO PAY ALL INSPECTION FEES AS MAY BE REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DA~E AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS RULES OR ORDINANCES

8 ALL WIRE COPPER IN RACEWAY UNLESS OTHERWISE SPECIFIED ON DRAWINGS

9 WIRE UP COMPLElE ALL THE AC EQUIPMENT AND CONTROLS AS DIRECTED BY AC CONTRACTOR CONTROL WIRING SHALL BE SEPARAlE RACEWAY FRO~ POWER WIRING

10 PROVIDE RACEWAYS AND PREWIRE TELEPHONE SYSTEM COMPLElELY WITH lELEshyPHONE JACKS

11 PROVIDE RACEWAYS AND PREWIRE CABLE TV SYSlEIA AS DIREClED BY CABLE TV Co FIELD REPRESENTATIVE

12 PROVIDE MEANS FIURNISH AND INSTALL

13 COORDINATE WORK WITH WORK OF OTHER TRADES TO AVOID ALL CONFLICTS

14 DO A COMPLElE JOB EVERYTHING CONNEClED READY FOR USE

15 PROVIDE TE~PORARY WIRING SYSTEM FOR USE OF ALL TRAIDES ADEQUATE FOR ENTIRE NEEDS OF THIS PROJECTS

16 PROVIDE PULL WIRES WHEN EMPTY CONDUITS ARE SHOWN ON TIHE PLANS

17 PROVIDE LIGHT FIXTURES AS PER OWNER SELECTION

18 PROVIDE ALL WIRING DEVICES

19 IDENTIFY CLEARLY ON A TYPE WRITlEN FOR~ ALL CIRCUITS AND EQUIP~ENT TO CORRESPOND WITH THE PLANS AND PANELS SCHEDULE AND ATIACH INSIDE THE PERTAINING PANEL

20 RACEWAYSmiddot ALL UNDERGROUND RACEWAYS TO BE PVC INSIDE CONCRETE SLAB EIAT WITH APPROVED SET SCREW FITIING INSIDE PARTITION EIAT ENT AND ROMEX WIRE WHERE ALLOWED FOR FLOOR PENETRATION USE ONLY EIAT

21 SHOP THIS CONTRACTOR SHALL FIURNISH THE ENGINEER WITH SHOP OF EQUIP~ENT PRIOR TO PURCHASE FOR APPROVAL

23 TESTINGmiddot THE CONTRACTOR SHALL TEST ALL WORK AND EQUIPMENT AS DIREClED BY TIHE ARCHITECT AND BY AUTHORITIES HAVING JURISDICTION FURNISHING ALL EQUIPMENT AND NECESSARY PERSONNEL AND ELECTRIC POWER THE ENTIRE INSTALLATION SHALL BE TESlED FOR SHORTS GROUNDS AND OPEN CIRCUITS AND ALL DEFECTS SHALL BE DEMONSTRATED TO BE IN PROPER WORKING AND OPERATING CONDITION TO THE COMPLElE SATISFACTION OF THE ENGINEER

24 GliARANJEESmiddot ALL EQUIP~ENT AND MATERIALS SHALL BE GUARANlEED FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE BY OWNER

25 AT COMPLETION OF JOB THE ELECTRICAL CONTRACTOR SHALL GIVE THE OWNER AN AS-BUILT SET OF REPRODUCIBLE SEPIAS SHOWING THE EXACT ELECTRICAL INSTALLATION

26 BEFORE BIDDING THE JOB THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS

PNL AMPS VOLTAGE CKTS WIRE PHASE MAIN MOUNT MANUFACTURER TYPE

150 120240 3040 3 1 LUGS FLUSH SIEMENS OR EO LOAD CENTER

CKT No WIRE COND

INCH

CKT BKR SERVING CKT

No WIRE COND INCH

CKT BKR SERVING

POLE AMPS POLE AMPS

1 r- shy

3 6 34 2 50 RANGE

(12KW)

2 12 12 1 20 SMALL APPL

4 12 12 1 20 SMALL APPL

5

7 6 34 2 50 AHU + ST HTR

(10KW+80KW)

6 12 12 1 20 BATH RECEPT

a 14 12 1 15 BEDROOM CKT

9

11 8 34 2 30 AIR COND UNIT

(440 KW)

10 14 12 1 15 BEDROO~ CKT

BEDROOM CKT12 14 12 1 15

13 r- shy

15 10 12 2 30

TANK WATER HEATER

(45 KW)

14 14 12 1 15 LIGHTS amp RECEPT

16 14 12 1 15 LIGHTS amp RECEPT

17 r- shy

19 10 12 2 30 DRYER

18 14 12 1 15 LIGHTS amp RECEPT

20 14 12 1 15 LIGHTS amp RECEPT

21 12 12 1 20 WASHER 22 12 12 1 20 GARAGE OPENER

23 12 12 1 20 KITCHEN HOOD 24 - - - - SPACE

25 12 12 1 20 DISH WASHER 26 - - - - SPACE

27 12 12 1 20 GARB DISPOSAL 28 - - - - SPACE

29 12 12 1 20 REFRIGERATOR 30 - - - - SPACE

NEC TABLE 220-30 ~

1990 SO FT 0 3 WATTSSO FT --~-c=-c=--- 60 TWO 20 AMP SMALL APPL CKT 0 1500 WATTS EACH___ 30 RANGE 120 TANK WATER HEATER 45 DRYER 50 WASHER 15 REFRIGERATOR 0 7 DISH WASHER 12 GARBAGE DISPOSAL 07 MICROWAVE 10 GARAGE DOOR OPENER 0 7

TOTAL WITHOUT DEMAND 363

FIRST 100 KW 0 100------------100 NEXT 263 KW 0 40 106

AHU + STRIP HEATER (10 KW + 80 KW x 100) 90

TOTAL CONNEClED LOAD 296

WATTS TO AMPS (LINE) 29600 240V = 124 AMPS

FEEDER TIHWN CU 311 amp 16 CU (GND) IN 1 12 PVC OR

THWN AL 220 amp 110 amp 16 CU (GND) IN 12 PVC (NEC 31 0-15(B)(6)

HEATING LOAD LARGER THAN COOLING LOAD

16

16

GREAT ROOM

(DihINS AREt_l

2 18

18

18

8

WIC

ltITC~EN

s

------shy1

I

I

I

I

I

I

I

I

I

I

I I I I I I

I I I I I I I I I I I I I I

- shy--F

a

II

20

TWO CARS SARASE

C I

12

10

3ATH

BEDROCi 3

~dpound0

12

1

CU-1

NEMA 3R EUCTJIIICAI MAINA lEiER COMeiNATION

bull ~ nshy- bull nrshylt - shy-~ 0

11~

I shymiddot-1()

Cl~E- LL~OOCo middot- 4 EXlaquogt

l middot-lL 0I Illt- w~ cpound)~ ~c

~ - gt 0 r- Oui~

~ o ~ 1() _

~ ~sd) shy oL s

w~bull I~ rlt1-

lt Ill ltt ltI)--1 ~()pound01L gtltIll)

au ltI)bull1()

11 -= -~$it 0 E rt----~

1()

11~ltl-ct ~(() ru~

tshy

0 ~~ 0 ~c

0 Q_

w 0Zlshylt(Zzw LL2 C) a

(sectz9 -w It(fJgt 0

_jJw lL

Oo ~I gt-gtshy z

J 1-1shy 0 zz ()

0JJ It 02 ~ 02 0 oo It

oO Ill

~~0 w z Olt(

s 0 0 Ill

jiijl 0 0 Itjiijl f--w

jiijl lt(()

tljJi

~ ()lt( (J)()(f)Ott

~ 0lt(ttU IN

A f-oeslt( lllZNw

0 I (J)()f-shy0lt11 0

~ It

-o 0 w Ill ()

TI-llS D~AWINC AND SPECIFICATIONS CCNTAINS PROPRIETARY INFOR-JATION A~D A~ TI-lE =~OFE~TI OF OCTAVIO A 3ANTURIJ AIAPA AlD MAY OT BE R~f-ROP~CI~ COF-IP OFlt PIS-RI6UTED wr--lOUT TI-lE EXPRESSED WRnEN PERM ISS ON AND C01PEI-SATION CF OCTAVIO A SANTURIO AlA FA

r- shy

r- shy

NOTES

BEFORE INSTALLATION THE ELECTRICAL CONTRACTOR SHALL VERIFY THE SIZE OF CKT BKR AND FEEDER WlTH THE AIC MANUFACTURERS REQUIREMENTS AND SHALL BE IN COMPLIANCE WITH NEG 424-3 440-22 AND 440-32

ALL 15A AND 20A BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT IN FAMILY ROOMS DINING ROOMS LIVING ROOMS PARLORS LIBRARIES DENS SUN ROOMS RECREATION ROOMS CLOSETS HALLWAYS OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC FAULT CIRCUIT INTERRUPTER DEVICE OF THE COMBINATION TYPE AS REQUIRED BY NEC 210-12fBi

ALL 15A AND 20A RECEPTACLES IN AREAS SPECIFIED IN NEC 21052 SHALL BE LISTED AS TAMPER RESISTANT RECEPTACLES AS REQUIRED BY NEG 40611

THE ELECTRICAL PANEL CONNECTIONS MUST BE UL LISTED FOR 60f75 CONDUCTORS IN COMPLIANCE WITH NEC 110-14(c) THE TEMPERATURE RATING ASSOCIATED WITH THE AMPACITY OF A CONDUCTOR SHALL BE SELECTED AND COORDINATED SO AS NOT TO EXCEED THE LOWEST TEMPERATURE RATING OF ANY CONNECTED TERMINATION CONDUCTOR OR DEVICE

ELECTRICAL RISER DIAGRAM NTS

THWN CU 3(11 amp 1 6 CU (GND) IN 1 12 PVC

OR THWN AL 2120 amp 11110 amp ELECT NEMA 3R

16 CU (GND) IN 1 12 PVC PANEL i 0 ELECTRICAL INSIDE MAINMElER HOUSE COMBINATION

I 4 cu NEMA 3R 2POLE 240V 150A MAIN BKR 22000 AIC

~ 34CW PIPE ~ TO COMPLY W 25094

(

GROUND TO BLDG STEEL REINFORCING BAR W~4 BARE CU CONDUCTO

(1) 10-0L x 58t -==shy GROUND ROD --

r-

2 PVC TO FPL SERVICE ENTRANCE r COORDINATE EXACT LOCTAION WITH

FPL REPRESENTATIVE

ELECTRICAL LEGEND THE USE OF ROMEX TYPE WIRE IS ACCEPTABLE IF IT IS IN COMPLIANCE120V HALF SWITCHED DUPLEX RECEPTACLE~ 0 4-amiddot CEILING SURFACE MOUNlED FLOURECENT LIGHT FIXTURE WITH NEC TABLE 310-16 FOR 60C

120V DUPLEX RECEPTACLE BATHROOM RECIRCULATING FANreg -e 120V SINGLE RECEPTACLE 120V ACBATIERY OPERATED CEILING MOUNTED SMOKE DETECTOR INTERCONNECTIED WITH OTHER SMOKE DIETECTORS INSIDE THE HOUSE

120V GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE FOR SIMULTANEOUS OPERATION SMOKE DETECTORS SHALL BE ALARM NOTE LOCATED 36 AWAY FROM ANY AC DIFFUSER AND FROM BATH AND ALARM SYSTEM BY ALARM CONTRACTOR KITCHEN DOORS SMOKE DETECTbRS SHALL BE PHOTO-ELECTRIC UNDER SEPARATE PERMIT 120V ABOVE COUNTER GROUND FAULT INTERRUPTER~ TYPE IF IT IS LOCATED WI1HIN 20 FROM KITCHEN APPL

DUPLEX RECEPTACLE

120V ACBATIERY OPERATED CEILING MOUNTED SMOKE AND- 240V 30A DRYER RECEPTACLE CARBON ~ONOXIDE DElECTOR INTERCONNEClED WITH OTHER S~OKE amp CARBON MONOXIDE DETECTORS INSIDE THE HOUSE FOR240V 50A RANGE RECEPTACLE-reg SIMULTANEOUS OPERATION SMOKE amp CARBON ~ONOXIDE DElECTORS SHALL BE LOCATED 36 AWAY FROM ANY AC 98-30472 CARBON MONOXIDE PROTECTIONLn TOGGLE SWITCH DIFFUSER AND FROM BATH AND KITCHEN DOORS S~dKE amp CARBON ~ONOXIDE DElECTORS SHALL BE PHOTO-ELECTRIC TYPE (1) DEFINITIONS FOR PURPOSES OF THIS RULE THE FOLLOWING DEFINITIONS~ 3 WAY TOGGLE SWITCH IF IT IS LOCATED WITHIN 20 FRO~ KITCHEN APPL SHALL APPLY

SERVICE LOCATION MUST BE AIPPROVED BY UTILITY CO

(a) CARBON MONOXIDE ALARM A DEVICE FOR THE PURPOSE OFGROUND FAULT INlERRUPTER GARAGE DOOR CONTROLLERTELEPHONE OUTLET DElECTING CARBON MONOXIp~ THAT PRODUCES A DISTINCT AUDIBLE ALAR~ AND IS LISTED OR LAt1ELED WI1H THE APPROPRLTE ~ TV OUTLET

JUNCTION BOX

STANDARD EITHER ANSIUL 2034-96 STANDARD FOR SINGLE ANDDOOR CHIME

0 MULTIPLE STATION CO ALARMS INCORPORATED HEREIN BY REFERENCE OR UL 2075-04 GAS AND VAPOR DIETECTOR SENSOR INCORPORATEDCEILING MOUNTED LIGHT FIXTURE HERE IN BY REFERENCE IN ACCORDANCE WITH ITS APPLICATIONPUSH BUTTON (b) FOSSIL FUEL COAL KEROSENE OIL FIUEL GASES OR OTHER ALL LIGHTING amp APPLIANCESI() WALL MOUNlED OUTLET PETROLEUM OR HYDROCARBON PRODUCT THAT EMITS CARBON ELECTRICAL PLAN MONOXIDE AS A BY- PRODUCT OF COMBUSTION SHALL BE ENERGY STAR LABELED DISCONNECT SWITCH NEMA 3RIQ) WALL MOUNTED JUNCTION BOX 14=1-IZ(2) EVERY BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS

INSIDE AHU FACTORY MOUNTED CIRCUIT BREAKER ISSUED ON OR AFTER 7 1 I 06 AND HAVING A FOSSIL-FIUEL BURNINGCEILING MOUNlED JUNCTION BOX WITH SPECIAL HEATER OR APPLIANCE A FIREPLACE OR AN ATIACHED GARAGE SHALL0 SUPPORT FOR CHANDELIER OR LIGHTFAN COMBINATION HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WI1HIN 10ELECTRICAL PANEL FEET OF EACH ROOM USED FOR SLEEPING PURPOSES

SECTION 404 ELECTRICAL POWER AND LIGHTING VAPOR PROOF CEILING LIGHT FIXTURE LIGHTOVP D (3) IN NEW CONSTRUCTION ALARMS SHALL RECEIVE THEIR PRIMARY POWER SYSTEMS

I I ELECTRICAL METERMAIN COMBINATION FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FRO~ THE LOCAL POWER UTILITY SUCH ALARMS SHALL HAVE BATIERY BACK UP

WEATHER PROOF 4041 LIGHTING EQUIPMENT

PADDLE CEILING FAN WITH LIGHT FIXTURE A MINIMUM OF 50 PERCENT OF THE LAMPS IN (4) COMBINATION SMOKECARBON MONOXIDE ALARMS SHALL BE LISTED ORMOTION DETECTOR OUTDOOR LIGHT FIXTURE LABELED BY A NATidNALLY RECOGNIZED TESTING LABORATORY PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS

DRAW

JOI-lN D HECKEr

OA5 DATE

JANUARY 2015 SCA_E

A5 51-lOWN )06 NO

1505

51-1EET

E = 1

I OF I 51-lEET5

  • M E P_Page_1
  • M E P_Page_2
  • M E P_Page_3
  • M E P_Page_4
Page 2: Model 3 MEP · 2015. 2. 11. · 3/4 refrigerant r-41 oa (puron} note: require programf.iable thermostat, see energy calculations & drawings. refrigerant lines shall be type "l" seamless

--

----

--

PLUMBING LEGEND

WH WATER HEATER SOIL OR WASTE UNE

co CLIEANOUT ---- shy VENT LINE

~VISIONS BY

GENERAL PLUMBING NOTES

1 ALL WORK SHALL CONFORM WITH ALL LOCAL STATE FEDERAL ORDINANCES AND BUILDING CODES GOVERNING THE INSTALLATION OF THE PLUMBING SYSTEM IF WORK AS LAID OUT INDICAnED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES BUILDING CODES AND REGULATIONS THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECTENGINEER BEFORE SUBMITTING A BID THE ARCHinECTENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED

2 THE DRAWINGS ARE TO BE CONSIDERED DIAGRAtAMATIC NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS UNUESS SPECIFIC DIMENSIONS ARE SHOWN THE STRUCTURAL ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXItAUtA HEAD ROOM AND SPACE CONDITIONS AT ALL POINTS WHERE HEAD ROOM OR SPACE CONDITIONS APPEAR INADEQUAnE ARCHITECTENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION THIS CONTRACTOR SHALL WITHOUT EXTRA CHARGE MAKE FIELD MODIFICATIONS IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK

3 EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBtAITTING A BID CONTRACTOR WILL BE REQUIRED TO FURNISH INSTALL ANDOR CONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEtAS SHOWN ON ANY OF THE ARCHinECTURAL AIR CONDITIONING ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPENshySE TO THE OWNER IF DISCREPANCIES CONFLICTS INTERFERENCES OR OMISSIONS OCCUR BETWEEN DRAWINGS NOTIFY IN WRITING THE ARCHinECTENGINEER IN AMPLE TltAE TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED

4 INSTALL MAnERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS OF WHICH IN HIS OPINION DO NOT PRESENT A NEAT AND WORKMANLIKE APPEARANCE REMOVAL AND REPLACEMENT IS TO BE DONE IMMEDIAnELY WHEN DIRECTIED BY THE OWNER IN WRITING AT THE SOLE EXPENSE OF THE CONTRACTOR

5 START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER CONTRACTORS TO RECEIVE HIS WORK THIS CONTRACTshyTOR SHALL REtAOVE AND REPLACE AT HIS EXPENSE ALL PLUMBING WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCES WITH OTHER TRADES

6 THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE FEES PERMITS ASSOCIATION DUES ROYALTIES AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK HE SHALL ALSO PAY ALL INSPECTION FEES AS MAY BE REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS RUUES OR ORDINANCES

7 PROVIDE MEANS FURNISHED AND INSTALL

8 DO A COMPLETE JOB EVERYTHING CONNECTIED READY FOR USE

9 SHOP DRAWINGS THIS CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL

1 0 AT COMPLIETION OF JOB THE PLUMBING CONTRACTOR SHALL GIVE THE OWNER AN AS-BUILT SET OF REPRODUCIBUE SEPIAS SHOWING THE EXACT INSTALLATION

11 PLUMBING CONTRACTOR SHALL PRESSURE nEST ALL PIPING AS REQUIRED BY CODE TEST SHALL BE WITNESSED AND APPROVED BY PROPER AUTHORITIES

12 THE PLUMBING CONTRACTOR SHALL WARRANT ALL WORKtAANSHIP AND MATERIALS FOR ONE YEAR FROM THE DAnE OF FINAL WORK ACCEPTANCE BY OWNER ANY BREAKDOWN OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE TO THE OWNER

13 PLUMBING FIXTURES SPECIFICATIONS TO BE SUBMITTED BY ARCHinECT AT A LAnER DAnE

14 PROVIDE SHUT-OFF VALVE FOR EACH FIXTURE

1 5 WHEREVER DISSIMILAR METALS ARE TO JOINED A DI-ELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES

16 PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING CONDENSATE DRAIN AND TRAP SEE AIR CONDITIONING PLANS FOR LOCATION OF UNITS AND DRAINS

17 MATERIALSmiddot

A COLD amp HOT WATER PIPING DOWNSTREAM OF WATER METER SHALL BE CPVC

B SANITARY WASTE AND VENT LINES SHALL BE PVC

C CONDENSAnE DRAIN PIPE SHALL BE INSULAnED PVC SCHEDULE 40

v VENT COLD WATER LINE

VTR VENT-THRU-ROOF --middot-- HOT WATER UNE

IAS-R BEDRCOI1

I I

( TUB

ll~~~I I =

(5 ru) JAll

rmiddot )ii1 k--

~

~ 2

Qr I

[--1 2cw ampCD CONDENSATE DRAIN 12HW ONw WASTE

cw COLD WATER 12 HB WVACUUM BREAKER -2 VENTamp VALVE ON RAISER+FCO FLUSH CLIEANOUT -M-- GATE VALVEFU FIXTURE UNITS _

RVD RELIEF VALVE DISCHARGE PIPING TURN DOWN

CD CONDENSATE DRAIN 0 PIPING TURN DOWN

---o PIPING TURN UPJl~ VTR (VENT THRU ROOF) -o- PIPING TURN UP

3 (5 FU)

rr~~~~~12 HB WVACUU~

~---------~ BREAKER amp VALVE I 0sectshyON RISER- 1 I I

I me II

EEDROOHl______ r ~

I -12CW DN plusmn== c

I I I I

- ALL SANITARY PIPING 2 OR LESS TO HAVE 14 MIN SLOPE

3 I I - ALL SANITARY PIPING 3 TO 6 TO HAVE 18 MIN SLOPE (5 FU)

- ALL SANITARY PIPING 8 OR LARGER TO HAVE 116 MIN SLOPE KITCI-Et~

-PROVIDE ANTI-SCALDING VALVE IIOF ON ALL TUBS AND SHOWERS

-PROVIDE SHUTOFF VALVE FOR EACH FIXTURE

- PROVIDE CLEAN OUTS AT EACH SOIL B WASTE STACKS

2VTR~W FOOD GRINDER

BEDROOMGREAT ROOcl S

bull ~ - nshy

bull nrshylt - shy-~ 0

11~

I shy middot-n Cl~E- LL~OOCo middot- 4 EXlaquogt

l middot-lL 0

t- w~ I Ill cpound)~

~ ~c- gt 0 r- Oui~

~---~ o ~ ol) middot shy

d) ~ ~s- oi s

w~bull I~ rlt1-

lt Ill ltI)--1 ~()pound01L gtltIll)

au ltI)bullol) bullbull

11 -= -~$it 0 E rt----~

ol)

ltlt 11~ ~(() ru~

tshy 0 -~

0-Ie

0 Q_

w 0Zlshylt(Zzw LL2 C) a

(sectz9 -w It(fJgt 0

__jJw lL

Oo ~I gt-gtshy z

J 1-1shy 0 zz ()

0JJ It 02 ~ 02 0 oo It

oO Ill

~~0 w z Olt(

s 0 0 Ill

jiijl 0 0 Itjiijl f--w

jiijl lt(()

tljJi

~ ()lt( (J)()(f)Ott

~ 0lt(ttU IN

A f-oeslt( lllZNw

0 -I (J)()f-shy0lt11 0

~ It

-o 0 w Ill ()

TI-llS D~AWINC AND SPECIFICATIONS CCNTAINS PROPRIETARY INFOR-JATION A~D A~ TI-lE =~OFE~TI OF OCTAVIO A 3ANTURIJ AIAPA AlD MAY OT BE R~f-ROP~CI~ COF-IP OFlt PIS-RI6UTED wr--lOUT TI-lE EXPRESSED WRnEN PERM ISS ON AND C01PEI-SATION CF OCTAVIO A SANTURIO AlA FA

FIXTURE CONNECTION SCHEDULE

ITEM cw CONN

HW CONN

TRAP SIZE

FU COUNT REMARKS

LAVATORY 12 12 1 14 1 BIDET 12 12 2 2 WATER CLOSET (TANK) 12 - 3 4 SHOWER 12 12 2 2 WANTI-SCALD ttiXING VALVE BATHTUB 12 12 2 2 WANTI-SCALD VALVE

BATH GROUP 5 FU

KITCHEN SINK 12 12 1 12 2

DISHWASHER - 12 1 12 2 WASHING MACHINE 12 12 2 2

HOSE BIB 12 - - - VACUUM BREAKER amp VALVE IN THE VERTICAL

6049 WAlER ]H_E FLOW VELOCITY OF THE WATER DISTRIBUTION SYSIDt SIWL BE CONTROLLED TO REDUCE ]HE middot laquo_WATER_ HAMMER A WATER-twIIER ARRESTOR SHALL BE INSTAllED WHERE QUICK-CLOSING VALVES ARE UTILIZED WAlER HAMMER ARRESTORS SHALL BE INSTAllED IN ACCORDANCE WITH THE IIANlFACTIJRERS SPECIFICATIONS WAlER HAMMER ARRESTORS SIWL CONFORM TO ASSE 1010

12 MIN 3 I

2 UG CD LINE ~~~I bull ~~~~~V~RADE 34 UG RVD LINE

bull 1~3H RVD Ill IE-__JII~ ~~L -pound_

TO OUTSIDE amp TERMINATE 6 ABOVE RNISH ~ ---~~ct~t~ V 1_1

middot~

GRADE 3 I )(14 FU)

-J 1 ------------------34CW---------------~THE DISCHARGE PIPE SHALL I 34CWNOT HAVE ANY TRAPPED

--------------------------lI 34 CW ON_VISIBLE AIR GAP OR AIR GAP SECTIONS AND SHALL HAVE A

I TO EWH tWo CARS I FITTING LOCATED IN THE SAME GARAGE ~

IROOM AS THE WATER HEATER MASTER WATER AS PER P2803_6 1_1 FB_C I SHUT-OFF VALVE

I- IN CONC BOXI

I I 1ishyI I - ~~~ ~~~2 WAY C~ I 34CW

TABLE P29032a FCO ~ AIMAXIMUM FLOW RATES AND CONSUMPTION FOR I ~--------------~ PLUMBING FIXTURES FIXTURES FITIINGS AND APPLIANCES I

PLU~tBING FIXTURE PLUMBING FIXTURE OR OR

FIXTURE FITIING FIXTURE FITIING

LAVATORY FAUCET 15 GPM AT 60 PSI

SHOWER HEADa 15 GPM AT 80 PSI

SINK FAUCET 15 GPM AT 60 PSI

WATER CLOSET 128 GALLONS PER FLUSHING CYCLE

DISHWASHER 65 GALLONS PER CYCLE OR LESS

WASH MACHINE WATER FACTOR OF 8 OR LOWER

I I I I I

I

3 (14 FU) 12 HB WVACUUM _J

I BREAKER amp VALVE ON RISER

~34CW I

1

3 (14 FU) -SANITARY LINE 34 WATER SERVICE CONNECTED CONNECTED TO SEWER MAIN SERVICE TO WATER METER BY UTILnY CO BEFORE INSTALLATION COORDINATE BEFORE INSTALLATION COORDINATE EXACT LOCATION AT FIELD EXACT LOCATION AT FIELD SEE SITE PLAN FOR CONTINUATION SEE SITE PLAN FOR CONTINUATION

I 7-12

-

I I I I I I

Ht-57-sectI I

~

__----PATI-t

I

-

I

I

F ~ iht

11_)CJ=---lt D I I

1-4 2-8 1-4

--

~~-======If

I

_j 1-b L 3-2 1-6 2-8

~ ___J~ 101 l~dmiddot(o~)~~- ()

I itgt ilr~n~ ~lt

~_

I l ~middot-e~middot

I

FOR 51 1 GAIlON PER MtiiTE = 3785 Lrn1 POUND PER SQUARE INCH = 6895 KPa

FIXTURE CLEARENCE FLAN FIXTURE CLEARENCE FLAN Vlt4bull14 a A HANDHELD SHOWER SPRAY IS AlSO A SHOWER HEAD b A CONSUMPilON TOLIRANCES SHAll BE DEIERMINED FROMMASTER 6ATHROOM 6ATH No2 REFERENCED STANDARDS c WATER FICTOR IN GAIIONS PER CYCLE PER CUBIC FOOT PLUMBING PLAN 14=1-IZ

ALL PLUMBING FIXTURE SHALL BE EPA WATER SENSE LABELED

DRAW

JOI-lN D I-IECKEr

OA5 DATE

JANUARY 2015 SCA_E

A5 51-lOWN )06 NO

1505

51-lEET

PL-1 I OF 2 51-lEET5

50 GAL ELECTRICAL

EWH

JJW

i til

o II ) o j middot~I

bullcwl [f-z i cWvmiddotlp

~VISIONS BY

I CW amp HWSERVICE RUN ABOVE CEILING SEE FLOOR PLAN FOR ROUTING

HEAT TRAPmiddot--- MINIMUM 3

DRAIN COCK

34

34

AIR GAP

RVD RISER

_ 34 RVD LINE TO OUTSIDE amp TERMINATE 6 ABOVE GRADE

WAlER HEAlER PIPING DETAIL NTS

WATER HEATER DATA

MARK STORAGE IN US GAL INPUT MANUFACTURER

MODEL No ELECTRICAL

DATA ENERGY

EFFICIENCY

EWH 50 45KW AOSMITH

PROMAX middot ECT-52 OR

EQUAL

24()1-lO 091

WATER HEATER TYPICAL WATER RISER DIAGRAM NT5

2 VTR

T I I jx~v SHUT-OFF VALVE -Jl_

12HB WVACUUM f-CW IN CONC BOXo

BREAKER amp VALVE 1J2 ON RISER

2 VTRgt 2

l----shy~-

34 WATER SERVICE CONNECTED~ bull shyTO WATER METER BY UTIUJY CO BEFORE INSTALLATION COORDINATE _

2EXACT LOCATION AT FIELD bull ( SEE SITE PLAN FOR CONTINUATION

---

3 (14 FU SANITARY LINE CONNECTED TO SEWER MAJN SERVICE BEFORE INSTALLATION COORDINATE EXACT LOCATION AT FIELD SEE SITE PLAN FOR CONTINUATION

TYPICAL SANITARY RISER DIAGRAM Nrs

2 VTR

Ill 1-ill_ I

I tmiddot I I - I-- 2 I I - I 2

II II

2 II I I I I

2

bull ~ onshy- bull onrshy

- 0lt shy-~ 0 I-

11~ middot-U Cl~E -lt) - LL~_ 0 EX d)OCo middot-lL 0l I Ill cpound)~t-- w~ ~c- gt 0 r- Oui~

~---~ ltOoo ~ 1f middot shy

~s ~

~d) oL s

w~bull I~ rlt1-

QJ lt --1 ~()pound01L gtell)

au ltI)bullU

11 -= -~ rt----~$it ) E

1f

~(() ru~ltlt 11~

t-- -~

0 )0 -lc

Q_

w 0Zlshylt(Zzw LL2 C) a

(sect -w z9

It 0(fJgt uJw _j

OoI ~ gt-gt- J

z 1-1- 0 zz ()

JJ 0 It

02 ~ 02 0 Itoo

oO Ill

0 w ~~ z Olt(

0s 0 Ill

0jiijl 0

jiijl It f-wlt(()jiijl tljJi()lt( (J)()(f)~ Ott 0lt(ttU~ IN

A f-oeslt( lllZ

0 NwI

(J)()

11 f shy0lt 0 It~ -o 0 w Ill ()

TI-llS D~AWINC AND SPECIFICATIONS CCNTAINS FROFRIETART INFOR-JATION A~D A~ TI-lE =~OFE~TI OF OCTAVIO A 3ANTURIJ AIAPA AlD MAY OT BE R~f-ROP~C~~ COF-IP OFlt PIS-RI6UTED wr--lOUT TI-lE EXFREOSED WRr-TEN FERMIS6 ON AND C01PEI-6ATION CF OTAVIO A OANTURIO AlA FA

DRAW

JOI-lN D I-IECKEr

OA5 DATE

JANUARY 2015 6CA_E

A5 51-lOWN )06 NO

1505

51-1EET

PL-2 2 OF 2 5HEET5

~VISIONS BY

GENERAL ELECTRICAL NOTES

1 ALL WORK SHALL CONFOR~ WITH ALL LOCAL STAlE FEDERAL ORDINANCES AND BUILDING CODES GOVERNING THE INSTALLATION OF THE ELECTRICAL SYSTE~ IF WORK AS LAID OUT INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES BUILDING CODES AND REGULAshyTIONS THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECT ENGINEER BEFORE SUB~ITTING A BID THE ARCHITECTENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED

2 THE DRAWING ARE TO BE CONSIDERED DIAGRAMMATIC NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE ~INOR ITE~S UNLESS SPECIFIC DI~ENSIONS ARE SHOWN THE STRUCTURAL ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK CHECK DRAWINGS OF ALL TRAIDES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND ~AINTAIN MAXI~U~ HEAD ROO~ OR SPACE CONDITIONS AT ALL POINTS WHERE HEAlD ROO~ OR SPACE CONDITIONS APPEAR INADEQUATE ARCHITECTENGINEERSHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION THIS CONTRACshyTOR SHALL WITHOUT EXTRA CHARGE MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK

3 EXA~INE ALL DRAWINGS CAREFULLY PRIOR TO SUB~ITTING A BID CONTRACTOR WILL BE REQUIRED TO FURNISH INSTALL ANDOR CONNECT WITH APPROPRIATE SERVICES ALL ELECTRICAL ITEMS SHOWN ON ANY OF THE ARCHITECTURAL PLU~BING AIR CONDITIONING SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPENSE TO TIHE OWNER IF DISCREPANCIES CONFLICTS INTERFERENCES OR O~ISSIONS OCCUR BETWEEN DRAWINGS NOTIFY IN WRITING THE ARCHITECT ENGINEER IN AMPLE TI~E TO PER~IT REVISIONS BEFORE TIHE BIDS ARE SUB~ITlED

4 VERIFY SERVICE CHARACTERISTICS LOCATION AND CONNECTION WI1H TELEPHONE AND ELECTRIC UTIUTY CO~PANIES PERFOR~ ALL WORK RELATED TO SERVICE IN STRICT ACCORDANCE WITH UTIUTY Co STANDARDS AND REQUIRE~ENTS

5 INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEshyMENT OF ITEM WHICH IN HIS OPINION DO NOT PRESENT A NEAT AND WORKMANshyLIKE APPEARANCE RE~OVAL AND REPLACEMENT IS TO BE DONE ~~~EDIATELY WHEN DIRECTED BY THE OWNER IN WRITING AT THE SOLE EXPENSE OF CONTRACshyTOR

6 START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER CONTRACTIDRS TO RECEIVE HIS WORK THIS CONTRACTOR SHALL REMOVE AND REPLACE AT HIS EXPENSE ALL ELECTRICAL WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRAIDES

7 THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE FEES PERMITS ASSOshyCIATION DUES ROYALTIES AND TAXES OF WIHATEVER NATURE SHALL APPLY TO THIS WORK HE SHALL ALSO PAY ALL INSPECTION FEES AS MAY BE REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DA~E AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS RULES OR ORDINANCES

8 ALL WIRE COPPER IN RACEWAY UNLESS OTHERWISE SPECIFIED ON DRAWINGS

9 WIRE UP COMPLElE ALL THE AC EQUIPMENT AND CONTROLS AS DIRECTED BY AC CONTRACTOR CONTROL WIRING SHALL BE SEPARAlE RACEWAY FRO~ POWER WIRING

10 PROVIDE RACEWAYS AND PREWIRE TELEPHONE SYSTEM COMPLElELY WITH lELEshyPHONE JACKS

11 PROVIDE RACEWAYS AND PREWIRE CABLE TV SYSlEIA AS DIREClED BY CABLE TV Co FIELD REPRESENTATIVE

12 PROVIDE MEANS FIURNISH AND INSTALL

13 COORDINATE WORK WITH WORK OF OTHER TRADES TO AVOID ALL CONFLICTS

14 DO A COMPLElE JOB EVERYTHING CONNEClED READY FOR USE

15 PROVIDE TE~PORARY WIRING SYSTEM FOR USE OF ALL TRAIDES ADEQUATE FOR ENTIRE NEEDS OF THIS PROJECTS

16 PROVIDE PULL WIRES WHEN EMPTY CONDUITS ARE SHOWN ON TIHE PLANS

17 PROVIDE LIGHT FIXTURES AS PER OWNER SELECTION

18 PROVIDE ALL WIRING DEVICES

19 IDENTIFY CLEARLY ON A TYPE WRITlEN FOR~ ALL CIRCUITS AND EQUIP~ENT TO CORRESPOND WITH THE PLANS AND PANELS SCHEDULE AND ATIACH INSIDE THE PERTAINING PANEL

20 RACEWAYSmiddot ALL UNDERGROUND RACEWAYS TO BE PVC INSIDE CONCRETE SLAB EIAT WITH APPROVED SET SCREW FITIING INSIDE PARTITION EIAT ENT AND ROMEX WIRE WHERE ALLOWED FOR FLOOR PENETRATION USE ONLY EIAT

21 SHOP THIS CONTRACTOR SHALL FIURNISH THE ENGINEER WITH SHOP OF EQUIP~ENT PRIOR TO PURCHASE FOR APPROVAL

23 TESTINGmiddot THE CONTRACTOR SHALL TEST ALL WORK AND EQUIPMENT AS DIREClED BY TIHE ARCHITECT AND BY AUTHORITIES HAVING JURISDICTION FURNISHING ALL EQUIPMENT AND NECESSARY PERSONNEL AND ELECTRIC POWER THE ENTIRE INSTALLATION SHALL BE TESlED FOR SHORTS GROUNDS AND OPEN CIRCUITS AND ALL DEFECTS SHALL BE DEMONSTRATED TO BE IN PROPER WORKING AND OPERATING CONDITION TO THE COMPLElE SATISFACTION OF THE ENGINEER

24 GliARANJEESmiddot ALL EQUIP~ENT AND MATERIALS SHALL BE GUARANlEED FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE BY OWNER

25 AT COMPLETION OF JOB THE ELECTRICAL CONTRACTOR SHALL GIVE THE OWNER AN AS-BUILT SET OF REPRODUCIBLE SEPIAS SHOWING THE EXACT ELECTRICAL INSTALLATION

26 BEFORE BIDDING THE JOB THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS

PNL AMPS VOLTAGE CKTS WIRE PHASE MAIN MOUNT MANUFACTURER TYPE

150 120240 3040 3 1 LUGS FLUSH SIEMENS OR EO LOAD CENTER

CKT No WIRE COND

INCH

CKT BKR SERVING CKT

No WIRE COND INCH

CKT BKR SERVING

POLE AMPS POLE AMPS

1 r- shy

3 6 34 2 50 RANGE

(12KW)

2 12 12 1 20 SMALL APPL

4 12 12 1 20 SMALL APPL

5

7 6 34 2 50 AHU + ST HTR

(10KW+80KW)

6 12 12 1 20 BATH RECEPT

a 14 12 1 15 BEDROOM CKT

9

11 8 34 2 30 AIR COND UNIT

(440 KW)

10 14 12 1 15 BEDROO~ CKT

BEDROOM CKT12 14 12 1 15

13 r- shy

15 10 12 2 30

TANK WATER HEATER

(45 KW)

14 14 12 1 15 LIGHTS amp RECEPT

16 14 12 1 15 LIGHTS amp RECEPT

17 r- shy

19 10 12 2 30 DRYER

18 14 12 1 15 LIGHTS amp RECEPT

20 14 12 1 15 LIGHTS amp RECEPT

21 12 12 1 20 WASHER 22 12 12 1 20 GARAGE OPENER

23 12 12 1 20 KITCHEN HOOD 24 - - - - SPACE

25 12 12 1 20 DISH WASHER 26 - - - - SPACE

27 12 12 1 20 GARB DISPOSAL 28 - - - - SPACE

29 12 12 1 20 REFRIGERATOR 30 - - - - SPACE

NEC TABLE 220-30 ~

1990 SO FT 0 3 WATTSSO FT --~-c=-c=--- 60 TWO 20 AMP SMALL APPL CKT 0 1500 WATTS EACH___ 30 RANGE 120 TANK WATER HEATER 45 DRYER 50 WASHER 15 REFRIGERATOR 0 7 DISH WASHER 12 GARBAGE DISPOSAL 07 MICROWAVE 10 GARAGE DOOR OPENER 0 7

TOTAL WITHOUT DEMAND 363

FIRST 100 KW 0 100------------100 NEXT 263 KW 0 40 106

AHU + STRIP HEATER (10 KW + 80 KW x 100) 90

TOTAL CONNEClED LOAD 296

WATTS TO AMPS (LINE) 29600 240V = 124 AMPS

FEEDER TIHWN CU 311 amp 16 CU (GND) IN 1 12 PVC OR

THWN AL 220 amp 110 amp 16 CU (GND) IN 12 PVC (NEC 31 0-15(B)(6)

HEATING LOAD LARGER THAN COOLING LOAD

16

16

GREAT ROOM

(DihINS AREt_l

2 18

18

18

8

WIC

ltITC~EN

s

------shy1

I

I

I

I

I

I

I

I

I

I

I I I I I I

I I I I I I I I I I I I I I

- shy--F

a

II

20

TWO CARS SARASE

C I

12

10

3ATH

BEDROCi 3

~dpound0

12

1

CU-1

NEMA 3R EUCTJIIICAI MAINA lEiER COMeiNATION

bull ~ nshy- bull nrshylt - shy-~ 0

11~

I shymiddot-1()

Cl~E- LL~OOCo middot- 4 EXlaquogt

l middot-lL 0I Illt- w~ cpound)~ ~c

~ - gt 0 r- Oui~

~ o ~ 1() _

~ ~sd) shy oL s

w~bull I~ rlt1-

lt Ill ltt ltI)--1 ~()pound01L gtltIll)

au ltI)bull1()

11 -= -~$it 0 E rt----~

1()

11~ltl-ct ~(() ru~

tshy

0 ~~ 0 ~c

0 Q_

w 0Zlshylt(Zzw LL2 C) a

(sectz9 -w It(fJgt 0

_jJw lL

Oo ~I gt-gtshy z

J 1-1shy 0 zz ()

0JJ It 02 ~ 02 0 oo It

oO Ill

~~0 w z Olt(

s 0 0 Ill

jiijl 0 0 Itjiijl f--w

jiijl lt(()

tljJi

~ ()lt( (J)()(f)Ott

~ 0lt(ttU IN

A f-oeslt( lllZNw

0 I (J)()f-shy0lt11 0

~ It

-o 0 w Ill ()

TI-llS D~AWINC AND SPECIFICATIONS CCNTAINS PROPRIETARY INFOR-JATION A~D A~ TI-lE =~OFE~TI OF OCTAVIO A 3ANTURIJ AIAPA AlD MAY OT BE R~f-ROP~CI~ COF-IP OFlt PIS-RI6UTED wr--lOUT TI-lE EXPRESSED WRnEN PERM ISS ON AND C01PEI-SATION CF OCTAVIO A SANTURIO AlA FA

r- shy

r- shy

NOTES

BEFORE INSTALLATION THE ELECTRICAL CONTRACTOR SHALL VERIFY THE SIZE OF CKT BKR AND FEEDER WlTH THE AIC MANUFACTURERS REQUIREMENTS AND SHALL BE IN COMPLIANCE WITH NEG 424-3 440-22 AND 440-32

ALL 15A AND 20A BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT IN FAMILY ROOMS DINING ROOMS LIVING ROOMS PARLORS LIBRARIES DENS SUN ROOMS RECREATION ROOMS CLOSETS HALLWAYS OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC FAULT CIRCUIT INTERRUPTER DEVICE OF THE COMBINATION TYPE AS REQUIRED BY NEC 210-12fBi

ALL 15A AND 20A RECEPTACLES IN AREAS SPECIFIED IN NEC 21052 SHALL BE LISTED AS TAMPER RESISTANT RECEPTACLES AS REQUIRED BY NEG 40611

THE ELECTRICAL PANEL CONNECTIONS MUST BE UL LISTED FOR 60f75 CONDUCTORS IN COMPLIANCE WITH NEC 110-14(c) THE TEMPERATURE RATING ASSOCIATED WITH THE AMPACITY OF A CONDUCTOR SHALL BE SELECTED AND COORDINATED SO AS NOT TO EXCEED THE LOWEST TEMPERATURE RATING OF ANY CONNECTED TERMINATION CONDUCTOR OR DEVICE

ELECTRICAL RISER DIAGRAM NTS

THWN CU 3(11 amp 1 6 CU (GND) IN 1 12 PVC

OR THWN AL 2120 amp 11110 amp ELECT NEMA 3R

16 CU (GND) IN 1 12 PVC PANEL i 0 ELECTRICAL INSIDE MAINMElER HOUSE COMBINATION

I 4 cu NEMA 3R 2POLE 240V 150A MAIN BKR 22000 AIC

~ 34CW PIPE ~ TO COMPLY W 25094

(

GROUND TO BLDG STEEL REINFORCING BAR W~4 BARE CU CONDUCTO

(1) 10-0L x 58t -==shy GROUND ROD --

r-

2 PVC TO FPL SERVICE ENTRANCE r COORDINATE EXACT LOCTAION WITH

FPL REPRESENTATIVE

ELECTRICAL LEGEND THE USE OF ROMEX TYPE WIRE IS ACCEPTABLE IF IT IS IN COMPLIANCE120V HALF SWITCHED DUPLEX RECEPTACLE~ 0 4-amiddot CEILING SURFACE MOUNlED FLOURECENT LIGHT FIXTURE WITH NEC TABLE 310-16 FOR 60C

120V DUPLEX RECEPTACLE BATHROOM RECIRCULATING FANreg -e 120V SINGLE RECEPTACLE 120V ACBATIERY OPERATED CEILING MOUNTED SMOKE DETECTOR INTERCONNECTIED WITH OTHER SMOKE DIETECTORS INSIDE THE HOUSE

120V GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE FOR SIMULTANEOUS OPERATION SMOKE DETECTORS SHALL BE ALARM NOTE LOCATED 36 AWAY FROM ANY AC DIFFUSER AND FROM BATH AND ALARM SYSTEM BY ALARM CONTRACTOR KITCHEN DOORS SMOKE DETECTbRS SHALL BE PHOTO-ELECTRIC UNDER SEPARATE PERMIT 120V ABOVE COUNTER GROUND FAULT INTERRUPTER~ TYPE IF IT IS LOCATED WI1HIN 20 FROM KITCHEN APPL

DUPLEX RECEPTACLE

120V ACBATIERY OPERATED CEILING MOUNTED SMOKE AND- 240V 30A DRYER RECEPTACLE CARBON ~ONOXIDE DElECTOR INTERCONNEClED WITH OTHER S~OKE amp CARBON MONOXIDE DETECTORS INSIDE THE HOUSE FOR240V 50A RANGE RECEPTACLE-reg SIMULTANEOUS OPERATION SMOKE amp CARBON ~ONOXIDE DElECTORS SHALL BE LOCATED 36 AWAY FROM ANY AC 98-30472 CARBON MONOXIDE PROTECTIONLn TOGGLE SWITCH DIFFUSER AND FROM BATH AND KITCHEN DOORS S~dKE amp CARBON ~ONOXIDE DElECTORS SHALL BE PHOTO-ELECTRIC TYPE (1) DEFINITIONS FOR PURPOSES OF THIS RULE THE FOLLOWING DEFINITIONS~ 3 WAY TOGGLE SWITCH IF IT IS LOCATED WITHIN 20 FRO~ KITCHEN APPL SHALL APPLY

SERVICE LOCATION MUST BE AIPPROVED BY UTILITY CO

(a) CARBON MONOXIDE ALARM A DEVICE FOR THE PURPOSE OFGROUND FAULT INlERRUPTER GARAGE DOOR CONTROLLERTELEPHONE OUTLET DElECTING CARBON MONOXIp~ THAT PRODUCES A DISTINCT AUDIBLE ALAR~ AND IS LISTED OR LAt1ELED WI1H THE APPROPRLTE ~ TV OUTLET

JUNCTION BOX

STANDARD EITHER ANSIUL 2034-96 STANDARD FOR SINGLE ANDDOOR CHIME

0 MULTIPLE STATION CO ALARMS INCORPORATED HEREIN BY REFERENCE OR UL 2075-04 GAS AND VAPOR DIETECTOR SENSOR INCORPORATEDCEILING MOUNTED LIGHT FIXTURE HERE IN BY REFERENCE IN ACCORDANCE WITH ITS APPLICATIONPUSH BUTTON (b) FOSSIL FUEL COAL KEROSENE OIL FIUEL GASES OR OTHER ALL LIGHTING amp APPLIANCESI() WALL MOUNlED OUTLET PETROLEUM OR HYDROCARBON PRODUCT THAT EMITS CARBON ELECTRICAL PLAN MONOXIDE AS A BY- PRODUCT OF COMBUSTION SHALL BE ENERGY STAR LABELED DISCONNECT SWITCH NEMA 3RIQ) WALL MOUNTED JUNCTION BOX 14=1-IZ(2) EVERY BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS

INSIDE AHU FACTORY MOUNTED CIRCUIT BREAKER ISSUED ON OR AFTER 7 1 I 06 AND HAVING A FOSSIL-FIUEL BURNINGCEILING MOUNlED JUNCTION BOX WITH SPECIAL HEATER OR APPLIANCE A FIREPLACE OR AN ATIACHED GARAGE SHALL0 SUPPORT FOR CHANDELIER OR LIGHTFAN COMBINATION HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WI1HIN 10ELECTRICAL PANEL FEET OF EACH ROOM USED FOR SLEEPING PURPOSES

SECTION 404 ELECTRICAL POWER AND LIGHTING VAPOR PROOF CEILING LIGHT FIXTURE LIGHTOVP D (3) IN NEW CONSTRUCTION ALARMS SHALL RECEIVE THEIR PRIMARY POWER SYSTEMS

I I ELECTRICAL METERMAIN COMBINATION FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FRO~ THE LOCAL POWER UTILITY SUCH ALARMS SHALL HAVE BATIERY BACK UP

WEATHER PROOF 4041 LIGHTING EQUIPMENT

PADDLE CEILING FAN WITH LIGHT FIXTURE A MINIMUM OF 50 PERCENT OF THE LAMPS IN (4) COMBINATION SMOKECARBON MONOXIDE ALARMS SHALL BE LISTED ORMOTION DETECTOR OUTDOOR LIGHT FIXTURE LABELED BY A NATidNALLY RECOGNIZED TESTING LABORATORY PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS

DRAW

JOI-lN D HECKEr

OA5 DATE

JANUARY 2015 SCA_E

A5 51-lOWN )06 NO

1505

51-1EET

E = 1

I OF I 51-lEET5

  • M E P_Page_1
  • M E P_Page_2
  • M E P_Page_3
  • M E P_Page_4
Page 3: Model 3 MEP · 2015. 2. 11. · 3/4 refrigerant r-41 oa (puron} note: require programf.iable thermostat, see energy calculations & drawings. refrigerant lines shall be type "l" seamless

50 GAL ELECTRICAL

EWH

JJW

i til

o II ) o j middot~I

bullcwl [f-z i cWvmiddotlp

~VISIONS BY

I CW amp HWSERVICE RUN ABOVE CEILING SEE FLOOR PLAN FOR ROUTING

HEAT TRAPmiddot--- MINIMUM 3

DRAIN COCK

34

34

AIR GAP

RVD RISER

_ 34 RVD LINE TO OUTSIDE amp TERMINATE 6 ABOVE GRADE

WAlER HEAlER PIPING DETAIL NTS

WATER HEATER DATA

MARK STORAGE IN US GAL INPUT MANUFACTURER

MODEL No ELECTRICAL

DATA ENERGY

EFFICIENCY

EWH 50 45KW AOSMITH

PROMAX middot ECT-52 OR

EQUAL

24()1-lO 091

WATER HEATER TYPICAL WATER RISER DIAGRAM NT5

2 VTR

T I I jx~v SHUT-OFF VALVE -Jl_

12HB WVACUUM f-CW IN CONC BOXo

BREAKER amp VALVE 1J2 ON RISER

2 VTRgt 2

l----shy~-

34 WATER SERVICE CONNECTED~ bull shyTO WATER METER BY UTIUJY CO BEFORE INSTALLATION COORDINATE _

2EXACT LOCATION AT FIELD bull ( SEE SITE PLAN FOR CONTINUATION

---

3 (14 FU SANITARY LINE CONNECTED TO SEWER MAJN SERVICE BEFORE INSTALLATION COORDINATE EXACT LOCATION AT FIELD SEE SITE PLAN FOR CONTINUATION

TYPICAL SANITARY RISER DIAGRAM Nrs

2 VTR

Ill 1-ill_ I

I tmiddot I I - I-- 2 I I - I 2

II II

2 II I I I I

2

bull ~ onshy- bull onrshy

- 0lt shy-~ 0 I-

11~ middot-U Cl~E -lt) - LL~_ 0 EX d)OCo middot-lL 0l I Ill cpound)~t-- w~ ~c- gt 0 r- Oui~

~---~ ltOoo ~ 1f middot shy

~s ~

~d) oL s

w~bull I~ rlt1-

QJ lt --1 ~()pound01L gtell)

au ltI)bullU

11 -= -~ rt----~$it ) E

1f

~(() ru~ltlt 11~

t-- -~

0 )0 -lc

Q_

w 0Zlshylt(Zzw LL2 C) a

(sect -w z9

It 0(fJgt uJw _j

OoI ~ gt-gt- J

z 1-1- 0 zz ()

JJ 0 It

02 ~ 02 0 Itoo

oO Ill

0 w ~~ z Olt(

0s 0 Ill

0jiijl 0

jiijl It f-wlt(()jiijl tljJi()lt( (J)()(f)~ Ott 0lt(ttU~ IN

A f-oeslt( lllZ

0 NwI

(J)()

11 f shy0lt 0 It~ -o 0 w Ill ()

TI-llS D~AWINC AND SPECIFICATIONS CCNTAINS FROFRIETART INFOR-JATION A~D A~ TI-lE =~OFE~TI OF OCTAVIO A 3ANTURIJ AIAPA AlD MAY OT BE R~f-ROP~C~~ COF-IP OFlt PIS-RI6UTED wr--lOUT TI-lE EXFREOSED WRr-TEN FERMIS6 ON AND C01PEI-6ATION CF OTAVIO A OANTURIO AlA FA

DRAW

JOI-lN D I-IECKEr

OA5 DATE

JANUARY 2015 6CA_E

A5 51-lOWN )06 NO

1505

51-1EET

PL-2 2 OF 2 5HEET5

~VISIONS BY

GENERAL ELECTRICAL NOTES

1 ALL WORK SHALL CONFOR~ WITH ALL LOCAL STAlE FEDERAL ORDINANCES AND BUILDING CODES GOVERNING THE INSTALLATION OF THE ELECTRICAL SYSTE~ IF WORK AS LAID OUT INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES BUILDING CODES AND REGULAshyTIONS THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECT ENGINEER BEFORE SUB~ITTING A BID THE ARCHITECTENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED

2 THE DRAWING ARE TO BE CONSIDERED DIAGRAMMATIC NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE ~INOR ITE~S UNLESS SPECIFIC DI~ENSIONS ARE SHOWN THE STRUCTURAL ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK CHECK DRAWINGS OF ALL TRAIDES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND ~AINTAIN MAXI~U~ HEAD ROO~ OR SPACE CONDITIONS AT ALL POINTS WHERE HEAlD ROO~ OR SPACE CONDITIONS APPEAR INADEQUATE ARCHITECTENGINEERSHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION THIS CONTRACshyTOR SHALL WITHOUT EXTRA CHARGE MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK

3 EXA~INE ALL DRAWINGS CAREFULLY PRIOR TO SUB~ITTING A BID CONTRACTOR WILL BE REQUIRED TO FURNISH INSTALL ANDOR CONNECT WITH APPROPRIATE SERVICES ALL ELECTRICAL ITEMS SHOWN ON ANY OF THE ARCHITECTURAL PLU~BING AIR CONDITIONING SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPENSE TO TIHE OWNER IF DISCREPANCIES CONFLICTS INTERFERENCES OR O~ISSIONS OCCUR BETWEEN DRAWINGS NOTIFY IN WRITING THE ARCHITECT ENGINEER IN AMPLE TI~E TO PER~IT REVISIONS BEFORE TIHE BIDS ARE SUB~ITlED

4 VERIFY SERVICE CHARACTERISTICS LOCATION AND CONNECTION WI1H TELEPHONE AND ELECTRIC UTIUTY CO~PANIES PERFOR~ ALL WORK RELATED TO SERVICE IN STRICT ACCORDANCE WITH UTIUTY Co STANDARDS AND REQUIRE~ENTS

5 INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEshyMENT OF ITEM WHICH IN HIS OPINION DO NOT PRESENT A NEAT AND WORKMANshyLIKE APPEARANCE RE~OVAL AND REPLACEMENT IS TO BE DONE ~~~EDIATELY WHEN DIRECTED BY THE OWNER IN WRITING AT THE SOLE EXPENSE OF CONTRACshyTOR

6 START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER CONTRACTIDRS TO RECEIVE HIS WORK THIS CONTRACTOR SHALL REMOVE AND REPLACE AT HIS EXPENSE ALL ELECTRICAL WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRAIDES

7 THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE FEES PERMITS ASSOshyCIATION DUES ROYALTIES AND TAXES OF WIHATEVER NATURE SHALL APPLY TO THIS WORK HE SHALL ALSO PAY ALL INSPECTION FEES AS MAY BE REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DA~E AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS RULES OR ORDINANCES

8 ALL WIRE COPPER IN RACEWAY UNLESS OTHERWISE SPECIFIED ON DRAWINGS

9 WIRE UP COMPLElE ALL THE AC EQUIPMENT AND CONTROLS AS DIRECTED BY AC CONTRACTOR CONTROL WIRING SHALL BE SEPARAlE RACEWAY FRO~ POWER WIRING

10 PROVIDE RACEWAYS AND PREWIRE TELEPHONE SYSTEM COMPLElELY WITH lELEshyPHONE JACKS

11 PROVIDE RACEWAYS AND PREWIRE CABLE TV SYSlEIA AS DIREClED BY CABLE TV Co FIELD REPRESENTATIVE

12 PROVIDE MEANS FIURNISH AND INSTALL

13 COORDINATE WORK WITH WORK OF OTHER TRADES TO AVOID ALL CONFLICTS

14 DO A COMPLElE JOB EVERYTHING CONNEClED READY FOR USE

15 PROVIDE TE~PORARY WIRING SYSTEM FOR USE OF ALL TRAIDES ADEQUATE FOR ENTIRE NEEDS OF THIS PROJECTS

16 PROVIDE PULL WIRES WHEN EMPTY CONDUITS ARE SHOWN ON TIHE PLANS

17 PROVIDE LIGHT FIXTURES AS PER OWNER SELECTION

18 PROVIDE ALL WIRING DEVICES

19 IDENTIFY CLEARLY ON A TYPE WRITlEN FOR~ ALL CIRCUITS AND EQUIP~ENT TO CORRESPOND WITH THE PLANS AND PANELS SCHEDULE AND ATIACH INSIDE THE PERTAINING PANEL

20 RACEWAYSmiddot ALL UNDERGROUND RACEWAYS TO BE PVC INSIDE CONCRETE SLAB EIAT WITH APPROVED SET SCREW FITIING INSIDE PARTITION EIAT ENT AND ROMEX WIRE WHERE ALLOWED FOR FLOOR PENETRATION USE ONLY EIAT

21 SHOP THIS CONTRACTOR SHALL FIURNISH THE ENGINEER WITH SHOP OF EQUIP~ENT PRIOR TO PURCHASE FOR APPROVAL

23 TESTINGmiddot THE CONTRACTOR SHALL TEST ALL WORK AND EQUIPMENT AS DIREClED BY TIHE ARCHITECT AND BY AUTHORITIES HAVING JURISDICTION FURNISHING ALL EQUIPMENT AND NECESSARY PERSONNEL AND ELECTRIC POWER THE ENTIRE INSTALLATION SHALL BE TESlED FOR SHORTS GROUNDS AND OPEN CIRCUITS AND ALL DEFECTS SHALL BE DEMONSTRATED TO BE IN PROPER WORKING AND OPERATING CONDITION TO THE COMPLElE SATISFACTION OF THE ENGINEER

24 GliARANJEESmiddot ALL EQUIP~ENT AND MATERIALS SHALL BE GUARANlEED FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE BY OWNER

25 AT COMPLETION OF JOB THE ELECTRICAL CONTRACTOR SHALL GIVE THE OWNER AN AS-BUILT SET OF REPRODUCIBLE SEPIAS SHOWING THE EXACT ELECTRICAL INSTALLATION

26 BEFORE BIDDING THE JOB THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS

PNL AMPS VOLTAGE CKTS WIRE PHASE MAIN MOUNT MANUFACTURER TYPE

150 120240 3040 3 1 LUGS FLUSH SIEMENS OR EO LOAD CENTER

CKT No WIRE COND

INCH

CKT BKR SERVING CKT

No WIRE COND INCH

CKT BKR SERVING

POLE AMPS POLE AMPS

1 r- shy

3 6 34 2 50 RANGE

(12KW)

2 12 12 1 20 SMALL APPL

4 12 12 1 20 SMALL APPL

5

7 6 34 2 50 AHU + ST HTR

(10KW+80KW)

6 12 12 1 20 BATH RECEPT

a 14 12 1 15 BEDROOM CKT

9

11 8 34 2 30 AIR COND UNIT

(440 KW)

10 14 12 1 15 BEDROO~ CKT

BEDROOM CKT12 14 12 1 15

13 r- shy

15 10 12 2 30

TANK WATER HEATER

(45 KW)

14 14 12 1 15 LIGHTS amp RECEPT

16 14 12 1 15 LIGHTS amp RECEPT

17 r- shy

19 10 12 2 30 DRYER

18 14 12 1 15 LIGHTS amp RECEPT

20 14 12 1 15 LIGHTS amp RECEPT

21 12 12 1 20 WASHER 22 12 12 1 20 GARAGE OPENER

23 12 12 1 20 KITCHEN HOOD 24 - - - - SPACE

25 12 12 1 20 DISH WASHER 26 - - - - SPACE

27 12 12 1 20 GARB DISPOSAL 28 - - - - SPACE

29 12 12 1 20 REFRIGERATOR 30 - - - - SPACE

NEC TABLE 220-30 ~

1990 SO FT 0 3 WATTSSO FT --~-c=-c=--- 60 TWO 20 AMP SMALL APPL CKT 0 1500 WATTS EACH___ 30 RANGE 120 TANK WATER HEATER 45 DRYER 50 WASHER 15 REFRIGERATOR 0 7 DISH WASHER 12 GARBAGE DISPOSAL 07 MICROWAVE 10 GARAGE DOOR OPENER 0 7

TOTAL WITHOUT DEMAND 363

FIRST 100 KW 0 100------------100 NEXT 263 KW 0 40 106

AHU + STRIP HEATER (10 KW + 80 KW x 100) 90

TOTAL CONNEClED LOAD 296

WATTS TO AMPS (LINE) 29600 240V = 124 AMPS

FEEDER TIHWN CU 311 amp 16 CU (GND) IN 1 12 PVC OR

THWN AL 220 amp 110 amp 16 CU (GND) IN 12 PVC (NEC 31 0-15(B)(6)

HEATING LOAD LARGER THAN COOLING LOAD

16

16

GREAT ROOM

(DihINS AREt_l

2 18

18

18

8

WIC

ltITC~EN

s

------shy1

I

I

I

I

I

I

I

I

I

I

I I I I I I

I I I I I I I I I I I I I I

- shy--F

a

II

20

TWO CARS SARASE

C I

12

10

3ATH

BEDROCi 3

~dpound0

12

1

CU-1

NEMA 3R EUCTJIIICAI MAINA lEiER COMeiNATION

bull ~ nshy- bull nrshylt - shy-~ 0

11~

I shymiddot-1()

Cl~E- LL~OOCo middot- 4 EXlaquogt

l middot-lL 0I Illt- w~ cpound)~ ~c

~ - gt 0 r- Oui~

~ o ~ 1() _

~ ~sd) shy oL s

w~bull I~ rlt1-

lt Ill ltt ltI)--1 ~()pound01L gtltIll)

au ltI)bull1()

11 -= -~$it 0 E rt----~

1()

11~ltl-ct ~(() ru~

tshy

0 ~~ 0 ~c

0 Q_

w 0Zlshylt(Zzw LL2 C) a

(sectz9 -w It(fJgt 0

_jJw lL

Oo ~I gt-gtshy z

J 1-1shy 0 zz ()

0JJ It 02 ~ 02 0 oo It

oO Ill

~~0 w z Olt(

s 0 0 Ill

jiijl 0 0 Itjiijl f--w

jiijl lt(()

tljJi

~ ()lt( (J)()(f)Ott

~ 0lt(ttU IN

A f-oeslt( lllZNw

0 I (J)()f-shy0lt11 0

~ It

-o 0 w Ill ()

TI-llS D~AWINC AND SPECIFICATIONS CCNTAINS PROPRIETARY INFOR-JATION A~D A~ TI-lE =~OFE~TI OF OCTAVIO A 3ANTURIJ AIAPA AlD MAY OT BE R~f-ROP~CI~ COF-IP OFlt PIS-RI6UTED wr--lOUT TI-lE EXPRESSED WRnEN PERM ISS ON AND C01PEI-SATION CF OCTAVIO A SANTURIO AlA FA

r- shy

r- shy

NOTES

BEFORE INSTALLATION THE ELECTRICAL CONTRACTOR SHALL VERIFY THE SIZE OF CKT BKR AND FEEDER WlTH THE AIC MANUFACTURERS REQUIREMENTS AND SHALL BE IN COMPLIANCE WITH NEG 424-3 440-22 AND 440-32

ALL 15A AND 20A BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT IN FAMILY ROOMS DINING ROOMS LIVING ROOMS PARLORS LIBRARIES DENS SUN ROOMS RECREATION ROOMS CLOSETS HALLWAYS OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC FAULT CIRCUIT INTERRUPTER DEVICE OF THE COMBINATION TYPE AS REQUIRED BY NEC 210-12fBi

ALL 15A AND 20A RECEPTACLES IN AREAS SPECIFIED IN NEC 21052 SHALL BE LISTED AS TAMPER RESISTANT RECEPTACLES AS REQUIRED BY NEG 40611

THE ELECTRICAL PANEL CONNECTIONS MUST BE UL LISTED FOR 60f75 CONDUCTORS IN COMPLIANCE WITH NEC 110-14(c) THE TEMPERATURE RATING ASSOCIATED WITH THE AMPACITY OF A CONDUCTOR SHALL BE SELECTED AND COORDINATED SO AS NOT TO EXCEED THE LOWEST TEMPERATURE RATING OF ANY CONNECTED TERMINATION CONDUCTOR OR DEVICE

ELECTRICAL RISER DIAGRAM NTS

THWN CU 3(11 amp 1 6 CU (GND) IN 1 12 PVC

OR THWN AL 2120 amp 11110 amp ELECT NEMA 3R

16 CU (GND) IN 1 12 PVC PANEL i 0 ELECTRICAL INSIDE MAINMElER HOUSE COMBINATION

I 4 cu NEMA 3R 2POLE 240V 150A MAIN BKR 22000 AIC

~ 34CW PIPE ~ TO COMPLY W 25094

(

GROUND TO BLDG STEEL REINFORCING BAR W~4 BARE CU CONDUCTO

(1) 10-0L x 58t -==shy GROUND ROD --

r-

2 PVC TO FPL SERVICE ENTRANCE r COORDINATE EXACT LOCTAION WITH

FPL REPRESENTATIVE

ELECTRICAL LEGEND THE USE OF ROMEX TYPE WIRE IS ACCEPTABLE IF IT IS IN COMPLIANCE120V HALF SWITCHED DUPLEX RECEPTACLE~ 0 4-amiddot CEILING SURFACE MOUNlED FLOURECENT LIGHT FIXTURE WITH NEC TABLE 310-16 FOR 60C

120V DUPLEX RECEPTACLE BATHROOM RECIRCULATING FANreg -e 120V SINGLE RECEPTACLE 120V ACBATIERY OPERATED CEILING MOUNTED SMOKE DETECTOR INTERCONNECTIED WITH OTHER SMOKE DIETECTORS INSIDE THE HOUSE

120V GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE FOR SIMULTANEOUS OPERATION SMOKE DETECTORS SHALL BE ALARM NOTE LOCATED 36 AWAY FROM ANY AC DIFFUSER AND FROM BATH AND ALARM SYSTEM BY ALARM CONTRACTOR KITCHEN DOORS SMOKE DETECTbRS SHALL BE PHOTO-ELECTRIC UNDER SEPARATE PERMIT 120V ABOVE COUNTER GROUND FAULT INTERRUPTER~ TYPE IF IT IS LOCATED WI1HIN 20 FROM KITCHEN APPL

DUPLEX RECEPTACLE

120V ACBATIERY OPERATED CEILING MOUNTED SMOKE AND- 240V 30A DRYER RECEPTACLE CARBON ~ONOXIDE DElECTOR INTERCONNEClED WITH OTHER S~OKE amp CARBON MONOXIDE DETECTORS INSIDE THE HOUSE FOR240V 50A RANGE RECEPTACLE-reg SIMULTANEOUS OPERATION SMOKE amp CARBON ~ONOXIDE DElECTORS SHALL BE LOCATED 36 AWAY FROM ANY AC 98-30472 CARBON MONOXIDE PROTECTIONLn TOGGLE SWITCH DIFFUSER AND FROM BATH AND KITCHEN DOORS S~dKE amp CARBON ~ONOXIDE DElECTORS SHALL BE PHOTO-ELECTRIC TYPE (1) DEFINITIONS FOR PURPOSES OF THIS RULE THE FOLLOWING DEFINITIONS~ 3 WAY TOGGLE SWITCH IF IT IS LOCATED WITHIN 20 FRO~ KITCHEN APPL SHALL APPLY

SERVICE LOCATION MUST BE AIPPROVED BY UTILITY CO

(a) CARBON MONOXIDE ALARM A DEVICE FOR THE PURPOSE OFGROUND FAULT INlERRUPTER GARAGE DOOR CONTROLLERTELEPHONE OUTLET DElECTING CARBON MONOXIp~ THAT PRODUCES A DISTINCT AUDIBLE ALAR~ AND IS LISTED OR LAt1ELED WI1H THE APPROPRLTE ~ TV OUTLET

JUNCTION BOX

STANDARD EITHER ANSIUL 2034-96 STANDARD FOR SINGLE ANDDOOR CHIME

0 MULTIPLE STATION CO ALARMS INCORPORATED HEREIN BY REFERENCE OR UL 2075-04 GAS AND VAPOR DIETECTOR SENSOR INCORPORATEDCEILING MOUNTED LIGHT FIXTURE HERE IN BY REFERENCE IN ACCORDANCE WITH ITS APPLICATIONPUSH BUTTON (b) FOSSIL FUEL COAL KEROSENE OIL FIUEL GASES OR OTHER ALL LIGHTING amp APPLIANCESI() WALL MOUNlED OUTLET PETROLEUM OR HYDROCARBON PRODUCT THAT EMITS CARBON ELECTRICAL PLAN MONOXIDE AS A BY- PRODUCT OF COMBUSTION SHALL BE ENERGY STAR LABELED DISCONNECT SWITCH NEMA 3RIQ) WALL MOUNTED JUNCTION BOX 14=1-IZ(2) EVERY BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS

INSIDE AHU FACTORY MOUNTED CIRCUIT BREAKER ISSUED ON OR AFTER 7 1 I 06 AND HAVING A FOSSIL-FIUEL BURNINGCEILING MOUNlED JUNCTION BOX WITH SPECIAL HEATER OR APPLIANCE A FIREPLACE OR AN ATIACHED GARAGE SHALL0 SUPPORT FOR CHANDELIER OR LIGHTFAN COMBINATION HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WI1HIN 10ELECTRICAL PANEL FEET OF EACH ROOM USED FOR SLEEPING PURPOSES

SECTION 404 ELECTRICAL POWER AND LIGHTING VAPOR PROOF CEILING LIGHT FIXTURE LIGHTOVP D (3) IN NEW CONSTRUCTION ALARMS SHALL RECEIVE THEIR PRIMARY POWER SYSTEMS

I I ELECTRICAL METERMAIN COMBINATION FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FRO~ THE LOCAL POWER UTILITY SUCH ALARMS SHALL HAVE BATIERY BACK UP

WEATHER PROOF 4041 LIGHTING EQUIPMENT

PADDLE CEILING FAN WITH LIGHT FIXTURE A MINIMUM OF 50 PERCENT OF THE LAMPS IN (4) COMBINATION SMOKECARBON MONOXIDE ALARMS SHALL BE LISTED ORMOTION DETECTOR OUTDOOR LIGHT FIXTURE LABELED BY A NATidNALLY RECOGNIZED TESTING LABORATORY PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS

DRAW

JOI-lN D HECKEr

OA5 DATE

JANUARY 2015 SCA_E

A5 51-lOWN )06 NO

1505

51-1EET

E = 1

I OF I 51-lEET5

  • M E P_Page_1
  • M E P_Page_2
  • M E P_Page_3
  • M E P_Page_4
Page 4: Model 3 MEP · 2015. 2. 11. · 3/4 refrigerant r-41 oa (puron} note: require programf.iable thermostat, see energy calculations & drawings. refrigerant lines shall be type "l" seamless

~VISIONS BY

GENERAL ELECTRICAL NOTES

1 ALL WORK SHALL CONFOR~ WITH ALL LOCAL STAlE FEDERAL ORDINANCES AND BUILDING CODES GOVERNING THE INSTALLATION OF THE ELECTRICAL SYSTE~ IF WORK AS LAID OUT INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES BUILDING CODES AND REGULAshyTIONS THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECT ENGINEER BEFORE SUB~ITTING A BID THE ARCHITECTENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED

2 THE DRAWING ARE TO BE CONSIDERED DIAGRAMMATIC NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE ~INOR ITE~S UNLESS SPECIFIC DI~ENSIONS ARE SHOWN THE STRUCTURAL ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK CHECK DRAWINGS OF ALL TRAIDES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND ~AINTAIN MAXI~U~ HEAD ROO~ OR SPACE CONDITIONS AT ALL POINTS WHERE HEAlD ROO~ OR SPACE CONDITIONS APPEAR INADEQUATE ARCHITECTENGINEERSHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION THIS CONTRACshyTOR SHALL WITHOUT EXTRA CHARGE MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK

3 EXA~INE ALL DRAWINGS CAREFULLY PRIOR TO SUB~ITTING A BID CONTRACTOR WILL BE REQUIRED TO FURNISH INSTALL ANDOR CONNECT WITH APPROPRIATE SERVICES ALL ELECTRICAL ITEMS SHOWN ON ANY OF THE ARCHITECTURAL PLU~BING AIR CONDITIONING SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPENSE TO TIHE OWNER IF DISCREPANCIES CONFLICTS INTERFERENCES OR O~ISSIONS OCCUR BETWEEN DRAWINGS NOTIFY IN WRITING THE ARCHITECT ENGINEER IN AMPLE TI~E TO PER~IT REVISIONS BEFORE TIHE BIDS ARE SUB~ITlED

4 VERIFY SERVICE CHARACTERISTICS LOCATION AND CONNECTION WI1H TELEPHONE AND ELECTRIC UTIUTY CO~PANIES PERFOR~ ALL WORK RELATED TO SERVICE IN STRICT ACCORDANCE WITH UTIUTY Co STANDARDS AND REQUIRE~ENTS

5 INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEshyMENT OF ITEM WHICH IN HIS OPINION DO NOT PRESENT A NEAT AND WORKMANshyLIKE APPEARANCE RE~OVAL AND REPLACEMENT IS TO BE DONE ~~~EDIATELY WHEN DIRECTED BY THE OWNER IN WRITING AT THE SOLE EXPENSE OF CONTRACshyTOR

6 START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER CONTRACTIDRS TO RECEIVE HIS WORK THIS CONTRACTOR SHALL REMOVE AND REPLACE AT HIS EXPENSE ALL ELECTRICAL WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRAIDES

7 THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE FEES PERMITS ASSOshyCIATION DUES ROYALTIES AND TAXES OF WIHATEVER NATURE SHALL APPLY TO THIS WORK HE SHALL ALSO PAY ALL INSPECTION FEES AS MAY BE REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DA~E AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS RULES OR ORDINANCES

8 ALL WIRE COPPER IN RACEWAY UNLESS OTHERWISE SPECIFIED ON DRAWINGS

9 WIRE UP COMPLElE ALL THE AC EQUIPMENT AND CONTROLS AS DIRECTED BY AC CONTRACTOR CONTROL WIRING SHALL BE SEPARAlE RACEWAY FRO~ POWER WIRING

10 PROVIDE RACEWAYS AND PREWIRE TELEPHONE SYSTEM COMPLElELY WITH lELEshyPHONE JACKS

11 PROVIDE RACEWAYS AND PREWIRE CABLE TV SYSlEIA AS DIREClED BY CABLE TV Co FIELD REPRESENTATIVE

12 PROVIDE MEANS FIURNISH AND INSTALL

13 COORDINATE WORK WITH WORK OF OTHER TRADES TO AVOID ALL CONFLICTS

14 DO A COMPLElE JOB EVERYTHING CONNEClED READY FOR USE

15 PROVIDE TE~PORARY WIRING SYSTEM FOR USE OF ALL TRAIDES ADEQUATE FOR ENTIRE NEEDS OF THIS PROJECTS

16 PROVIDE PULL WIRES WHEN EMPTY CONDUITS ARE SHOWN ON TIHE PLANS

17 PROVIDE LIGHT FIXTURES AS PER OWNER SELECTION

18 PROVIDE ALL WIRING DEVICES

19 IDENTIFY CLEARLY ON A TYPE WRITlEN FOR~ ALL CIRCUITS AND EQUIP~ENT TO CORRESPOND WITH THE PLANS AND PANELS SCHEDULE AND ATIACH INSIDE THE PERTAINING PANEL

20 RACEWAYSmiddot ALL UNDERGROUND RACEWAYS TO BE PVC INSIDE CONCRETE SLAB EIAT WITH APPROVED SET SCREW FITIING INSIDE PARTITION EIAT ENT AND ROMEX WIRE WHERE ALLOWED FOR FLOOR PENETRATION USE ONLY EIAT

21 SHOP THIS CONTRACTOR SHALL FIURNISH THE ENGINEER WITH SHOP OF EQUIP~ENT PRIOR TO PURCHASE FOR APPROVAL

23 TESTINGmiddot THE CONTRACTOR SHALL TEST ALL WORK AND EQUIPMENT AS DIREClED BY TIHE ARCHITECT AND BY AUTHORITIES HAVING JURISDICTION FURNISHING ALL EQUIPMENT AND NECESSARY PERSONNEL AND ELECTRIC POWER THE ENTIRE INSTALLATION SHALL BE TESlED FOR SHORTS GROUNDS AND OPEN CIRCUITS AND ALL DEFECTS SHALL BE DEMONSTRATED TO BE IN PROPER WORKING AND OPERATING CONDITION TO THE COMPLElE SATISFACTION OF THE ENGINEER

24 GliARANJEESmiddot ALL EQUIP~ENT AND MATERIALS SHALL BE GUARANlEED FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE BY OWNER

25 AT COMPLETION OF JOB THE ELECTRICAL CONTRACTOR SHALL GIVE THE OWNER AN AS-BUILT SET OF REPRODUCIBLE SEPIAS SHOWING THE EXACT ELECTRICAL INSTALLATION

26 BEFORE BIDDING THE JOB THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS

PNL AMPS VOLTAGE CKTS WIRE PHASE MAIN MOUNT MANUFACTURER TYPE

150 120240 3040 3 1 LUGS FLUSH SIEMENS OR EO LOAD CENTER

CKT No WIRE COND

INCH

CKT BKR SERVING CKT

No WIRE COND INCH

CKT BKR SERVING

POLE AMPS POLE AMPS

1 r- shy

3 6 34 2 50 RANGE

(12KW)

2 12 12 1 20 SMALL APPL

4 12 12 1 20 SMALL APPL

5

7 6 34 2 50 AHU + ST HTR

(10KW+80KW)

6 12 12 1 20 BATH RECEPT

a 14 12 1 15 BEDROOM CKT

9

11 8 34 2 30 AIR COND UNIT

(440 KW)

10 14 12 1 15 BEDROO~ CKT

BEDROOM CKT12 14 12 1 15

13 r- shy

15 10 12 2 30

TANK WATER HEATER

(45 KW)

14 14 12 1 15 LIGHTS amp RECEPT

16 14 12 1 15 LIGHTS amp RECEPT

17 r- shy

19 10 12 2 30 DRYER

18 14 12 1 15 LIGHTS amp RECEPT

20 14 12 1 15 LIGHTS amp RECEPT

21 12 12 1 20 WASHER 22 12 12 1 20 GARAGE OPENER

23 12 12 1 20 KITCHEN HOOD 24 - - - - SPACE

25 12 12 1 20 DISH WASHER 26 - - - - SPACE

27 12 12 1 20 GARB DISPOSAL 28 - - - - SPACE

29 12 12 1 20 REFRIGERATOR 30 - - - - SPACE

NEC TABLE 220-30 ~

1990 SO FT 0 3 WATTSSO FT --~-c=-c=--- 60 TWO 20 AMP SMALL APPL CKT 0 1500 WATTS EACH___ 30 RANGE 120 TANK WATER HEATER 45 DRYER 50 WASHER 15 REFRIGERATOR 0 7 DISH WASHER 12 GARBAGE DISPOSAL 07 MICROWAVE 10 GARAGE DOOR OPENER 0 7

TOTAL WITHOUT DEMAND 363

FIRST 100 KW 0 100------------100 NEXT 263 KW 0 40 106

AHU + STRIP HEATER (10 KW + 80 KW x 100) 90

TOTAL CONNEClED LOAD 296

WATTS TO AMPS (LINE) 29600 240V = 124 AMPS

FEEDER TIHWN CU 311 amp 16 CU (GND) IN 1 12 PVC OR

THWN AL 220 amp 110 amp 16 CU (GND) IN 12 PVC (NEC 31 0-15(B)(6)

HEATING LOAD LARGER THAN COOLING LOAD

16

16

GREAT ROOM

(DihINS AREt_l

2 18

18

18

8

WIC

ltITC~EN

s

------shy1

I

I

I

I

I

I

I

I

I

I

I I I I I I

I I I I I I I I I I I I I I

- shy--F

a

II

20

TWO CARS SARASE

C I

12

10

3ATH

BEDROCi 3

~dpound0

12

1

CU-1

NEMA 3R EUCTJIIICAI MAINA lEiER COMeiNATION

bull ~ nshy- bull nrshylt - shy-~ 0

11~

I shymiddot-1()

Cl~E- LL~OOCo middot- 4 EXlaquogt

l middot-lL 0I Illt- w~ cpound)~ ~c

~ - gt 0 r- Oui~

~ o ~ 1() _

~ ~sd) shy oL s

w~bull I~ rlt1-

lt Ill ltt ltI)--1 ~()pound01L gtltIll)

au ltI)bull1()

11 -= -~$it 0 E rt----~

1()

11~ltl-ct ~(() ru~

tshy

0 ~~ 0 ~c

0 Q_

w 0Zlshylt(Zzw LL2 C) a

(sectz9 -w It(fJgt 0

_jJw lL

Oo ~I gt-gtshy z

J 1-1shy 0 zz ()

0JJ It 02 ~ 02 0 oo It

oO Ill

~~0 w z Olt(

s 0 0 Ill

jiijl 0 0 Itjiijl f--w

jiijl lt(()

tljJi

~ ()lt( (J)()(f)Ott

~ 0lt(ttU IN

A f-oeslt( lllZNw

0 I (J)()f-shy0lt11 0

~ It

-o 0 w Ill ()

TI-llS D~AWINC AND SPECIFICATIONS CCNTAINS PROPRIETARY INFOR-JATION A~D A~ TI-lE =~OFE~TI OF OCTAVIO A 3ANTURIJ AIAPA AlD MAY OT BE R~f-ROP~CI~ COF-IP OFlt PIS-RI6UTED wr--lOUT TI-lE EXPRESSED WRnEN PERM ISS ON AND C01PEI-SATION CF OCTAVIO A SANTURIO AlA FA

r- shy

r- shy

NOTES

BEFORE INSTALLATION THE ELECTRICAL CONTRACTOR SHALL VERIFY THE SIZE OF CKT BKR AND FEEDER WlTH THE AIC MANUFACTURERS REQUIREMENTS AND SHALL BE IN COMPLIANCE WITH NEG 424-3 440-22 AND 440-32

ALL 15A AND 20A BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT IN FAMILY ROOMS DINING ROOMS LIVING ROOMS PARLORS LIBRARIES DENS SUN ROOMS RECREATION ROOMS CLOSETS HALLWAYS OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC FAULT CIRCUIT INTERRUPTER DEVICE OF THE COMBINATION TYPE AS REQUIRED BY NEC 210-12fBi

ALL 15A AND 20A RECEPTACLES IN AREAS SPECIFIED IN NEC 21052 SHALL BE LISTED AS TAMPER RESISTANT RECEPTACLES AS REQUIRED BY NEG 40611

THE ELECTRICAL PANEL CONNECTIONS MUST BE UL LISTED FOR 60f75 CONDUCTORS IN COMPLIANCE WITH NEC 110-14(c) THE TEMPERATURE RATING ASSOCIATED WITH THE AMPACITY OF A CONDUCTOR SHALL BE SELECTED AND COORDINATED SO AS NOT TO EXCEED THE LOWEST TEMPERATURE RATING OF ANY CONNECTED TERMINATION CONDUCTOR OR DEVICE

ELECTRICAL RISER DIAGRAM NTS

THWN CU 3(11 amp 1 6 CU (GND) IN 1 12 PVC

OR THWN AL 2120 amp 11110 amp ELECT NEMA 3R

16 CU (GND) IN 1 12 PVC PANEL i 0 ELECTRICAL INSIDE MAINMElER HOUSE COMBINATION

I 4 cu NEMA 3R 2POLE 240V 150A MAIN BKR 22000 AIC

~ 34CW PIPE ~ TO COMPLY W 25094

(

GROUND TO BLDG STEEL REINFORCING BAR W~4 BARE CU CONDUCTO

(1) 10-0L x 58t -==shy GROUND ROD --

r-

2 PVC TO FPL SERVICE ENTRANCE r COORDINATE EXACT LOCTAION WITH

FPL REPRESENTATIVE

ELECTRICAL LEGEND THE USE OF ROMEX TYPE WIRE IS ACCEPTABLE IF IT IS IN COMPLIANCE120V HALF SWITCHED DUPLEX RECEPTACLE~ 0 4-amiddot CEILING SURFACE MOUNlED FLOURECENT LIGHT FIXTURE WITH NEC TABLE 310-16 FOR 60C

120V DUPLEX RECEPTACLE BATHROOM RECIRCULATING FANreg -e 120V SINGLE RECEPTACLE 120V ACBATIERY OPERATED CEILING MOUNTED SMOKE DETECTOR INTERCONNECTIED WITH OTHER SMOKE DIETECTORS INSIDE THE HOUSE

120V GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE FOR SIMULTANEOUS OPERATION SMOKE DETECTORS SHALL BE ALARM NOTE LOCATED 36 AWAY FROM ANY AC DIFFUSER AND FROM BATH AND ALARM SYSTEM BY ALARM CONTRACTOR KITCHEN DOORS SMOKE DETECTbRS SHALL BE PHOTO-ELECTRIC UNDER SEPARATE PERMIT 120V ABOVE COUNTER GROUND FAULT INTERRUPTER~ TYPE IF IT IS LOCATED WI1HIN 20 FROM KITCHEN APPL

DUPLEX RECEPTACLE

120V ACBATIERY OPERATED CEILING MOUNTED SMOKE AND- 240V 30A DRYER RECEPTACLE CARBON ~ONOXIDE DElECTOR INTERCONNEClED WITH OTHER S~OKE amp CARBON MONOXIDE DETECTORS INSIDE THE HOUSE FOR240V 50A RANGE RECEPTACLE-reg SIMULTANEOUS OPERATION SMOKE amp CARBON ~ONOXIDE DElECTORS SHALL BE LOCATED 36 AWAY FROM ANY AC 98-30472 CARBON MONOXIDE PROTECTIONLn TOGGLE SWITCH DIFFUSER AND FROM BATH AND KITCHEN DOORS S~dKE amp CARBON ~ONOXIDE DElECTORS SHALL BE PHOTO-ELECTRIC TYPE (1) DEFINITIONS FOR PURPOSES OF THIS RULE THE FOLLOWING DEFINITIONS~ 3 WAY TOGGLE SWITCH IF IT IS LOCATED WITHIN 20 FRO~ KITCHEN APPL SHALL APPLY

SERVICE LOCATION MUST BE AIPPROVED BY UTILITY CO

(a) CARBON MONOXIDE ALARM A DEVICE FOR THE PURPOSE OFGROUND FAULT INlERRUPTER GARAGE DOOR CONTROLLERTELEPHONE OUTLET DElECTING CARBON MONOXIp~ THAT PRODUCES A DISTINCT AUDIBLE ALAR~ AND IS LISTED OR LAt1ELED WI1H THE APPROPRLTE ~ TV OUTLET

JUNCTION BOX

STANDARD EITHER ANSIUL 2034-96 STANDARD FOR SINGLE ANDDOOR CHIME

0 MULTIPLE STATION CO ALARMS INCORPORATED HEREIN BY REFERENCE OR UL 2075-04 GAS AND VAPOR DIETECTOR SENSOR INCORPORATEDCEILING MOUNTED LIGHT FIXTURE HERE IN BY REFERENCE IN ACCORDANCE WITH ITS APPLICATIONPUSH BUTTON (b) FOSSIL FUEL COAL KEROSENE OIL FIUEL GASES OR OTHER ALL LIGHTING amp APPLIANCESI() WALL MOUNlED OUTLET PETROLEUM OR HYDROCARBON PRODUCT THAT EMITS CARBON ELECTRICAL PLAN MONOXIDE AS A BY- PRODUCT OF COMBUSTION SHALL BE ENERGY STAR LABELED DISCONNECT SWITCH NEMA 3RIQ) WALL MOUNTED JUNCTION BOX 14=1-IZ(2) EVERY BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS

INSIDE AHU FACTORY MOUNTED CIRCUIT BREAKER ISSUED ON OR AFTER 7 1 I 06 AND HAVING A FOSSIL-FIUEL BURNINGCEILING MOUNlED JUNCTION BOX WITH SPECIAL HEATER OR APPLIANCE A FIREPLACE OR AN ATIACHED GARAGE SHALL0 SUPPORT FOR CHANDELIER OR LIGHTFAN COMBINATION HAVE AN OPERATIONAL CARBON MONOXIDE ALARM INSTALLED WI1HIN 10ELECTRICAL PANEL FEET OF EACH ROOM USED FOR SLEEPING PURPOSES

SECTION 404 ELECTRICAL POWER AND LIGHTING VAPOR PROOF CEILING LIGHT FIXTURE LIGHTOVP D (3) IN NEW CONSTRUCTION ALARMS SHALL RECEIVE THEIR PRIMARY POWER SYSTEMS

I I ELECTRICAL METERMAIN COMBINATION FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FRO~ THE LOCAL POWER UTILITY SUCH ALARMS SHALL HAVE BATIERY BACK UP

WEATHER PROOF 4041 LIGHTING EQUIPMENT

PADDLE CEILING FAN WITH LIGHT FIXTURE A MINIMUM OF 50 PERCENT OF THE LAMPS IN (4) COMBINATION SMOKECARBON MONOXIDE ALARMS SHALL BE LISTED ORMOTION DETECTOR OUTDOOR LIGHT FIXTURE LABELED BY A NATidNALLY RECOGNIZED TESTING LABORATORY PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS

DRAW

JOI-lN D HECKEr

OA5 DATE

JANUARY 2015 SCA_E

A5 51-lOWN )06 NO

1505

51-1EET

E = 1

I OF I 51-lEET5