Top Banner
Mobility Measurement of Non- Denatured Protein and Protein Cluster Ions by DMA-MS Christopher J. Hogan 1 & Juan Fernandez de la Mora 2 1 Mechanical Engineering, University of Minnesota 2 Mechanical Engineering, Yale University
20

Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Apr 19, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Mobility Measurement of Non-Denatured Protein and Protein Cluster

Ions by DMA-MSChristopher J. Hogan1 & Juan Fernandez de la Mora2

1 Mechanical Engineering, University of Minnesota2 Mechanical Engineering, Yale University

Page 2: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Outline• Introduction & Methods

– Motivation– Operating principle of DMA-MS– Study of charge-reduced protein and protein

cluster ions

• Results– Tandem mobility-mass plots– Inferring protein “size” from shape– Comparison to GEMMA results– Comparison to drift-tube IMS-MS

• Summary & Conclusions

Page 3: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Motivation• Goal of gas-phase mobility measurement:

– Infer protein/complex structure or changes to structure in solution.

– Electrospray under non-denaturing conditions– Maintain structural integrity prior to and during

mobility measurement

• Drift tube IMS or SYNAPT HDMS:– Often several high field regions

Source: www.waters.com

Source: Shelimov et al., 1997

Page 4: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Differential Mobility Analyzer• Parallel Plate DMA

– Spatial Mobility Filter• Constant Stream

Monomobile Ions

– Separation at Atmospheric Pressure

– Good Ion Transmission (> 50% of selected mobility)

– High Resolving Power• SEADM DMA P3: R > 70

• SEADM DMA P4: R ~ 50

– Can be installed on the front end of commercial mass spectrometer

SEADM DMA P4

Electrospray Ionization Chamber

Separation Region

To MS

DMAp LV

UZ2δ

=

Zp : ion mobility

Inlet

Outlet

δ

Selected Ion

+ L

Sheath Velocity, U

VI VO

VDMA= VI - VO

Page 5: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

DMA-MS• DMA P4 coupled to QSTAR XL (Sciex)

– Enables measurement of tandem mobility-mass spectra in a wide mobility and mass range (up to 40,000 in m/z).

– Used with ESI source

DMA

System Control

Box

Blower

Page 6: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Goals• Electrospray globular protein & protein cluster

ions under non-denaturating conditions

• From tandem mass-mobility spectra, infer protein sizes– Accounting for surface roughness and diffuse collisions

– Compare to:• GEMMA (Gas-phase electrophoretic macromolecular

mobility analyzer)

• Drift tube IMS-MS data

Page 7: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Electrospray Ionization• 40 µm I.D., 360 µm O. D. capillary

• Use of charge reducing buffer triethylammonium formate.

• Mitigates Coulombic stretching as well as polarization influences (Air, 8.7 times more polarizable than He)

With Triethylammonium+

From Hogan et al. 2009

With Ammonium Acetate+

Page 8: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

DMA Calibration• DMA sheath flow (> 100 l

min-1) must be determined.– Simpler to measure

mobility of a standard ion– DMA is a linear

spectrometer, with the voltages applied measurement is made in the low-field limit.

– Calibrant mobilities known in air at 20o C (Ude and Fernandez de la Mora, 2005).

– DMA runs at 30o C.– Choose largest singly

charged calibrant possible

(Tetraheptylammonium-Bromide)2 Tetraheptylammonium+

– Adjust mobility assuming ion is ~hard sphere.

R > 50

DMA

ss

VVZ

Z =

Page 9: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Results

Lysosyme Ions, no declustering

•Protein concentrations of ~10-30 µM used.

•Results in formation of protein cluster ions.

•Range: Cytochrome C momoners (12.2 kDa) to Concanavalin A hexamers (~150 kDa)

•Mobility measurement made before any declustering

•Declustering aids in sharpening mass peaks

•Residual solute possibly bound to protein ions (increases peak FWHM)

•Declustering promotes charge loss between the DMA and MS.

•Fragmentation of multimer ions minimal

•All observed peaks can be attributed to a specific multimer ion with a specific charge state with declustering

Page 10: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Results• Fragmentation is observed for GroEL 14-mers

Page 11: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Results

Page 12: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Results

Page 13: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Coulombic Stretching & Polarization

( ) g

B

giIig mTk

ddpze

mm ππα 89

)8/1(/1 2++=

+Ζ•Hard sphere

mobility equation:

•Hard sphere mobility equation- Ω = π/4(di+dg)2(1+παI/8)•(z/Z)1/2 ~ Ω1/2 (Length scale)•For compact ions, without Coulombic stretching and polarization influences (z/Z)1/2 ~ m1/3 (m: ion mass)

•Linear relationship implies minimal polarization effect/ Coulombic stretching•Measured ions are reasonably compact

Page 14: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Coulombic Stretching & Polarization• Without charge reducing buffer, effects of Coulombic stretching and

polarization observed (still a small effect with charge reducing buffer)

GroEL 14 mers,Electrosprayed in NH4Ac buffer

Page 15: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Inferring Cross-Sections/ Diameters

( ) g

B

giIig mTk

ddpze

mm ππα 89

)8/1(/1 2++=

Momentum Accommodation coefficientIn Air (and N2), known to be 0.91 1,2.

1. Davies, C. N., Definitive equations for the fluid resistance of spheres. Proceedings of the Physical Society 1945, 57, 259-270.2. Allen, M. D.; Raabe, O. G., Re-evaluation of Millikan's oil drop data for the motion of small particles in air. Journal of Aerosol Science 1982, 13, 537.

dg: bath gas diameter

di: ion “diameter”, independent of bath gas. For sufficiently large spherical ions, di is the volume diameter

Ω: Collision cross-section. Gas dependent, but best used for model (EHSS) comparisons (if the model is fine enough to capture multiple scattering events)

EMI-BF4 cluster measurement from Larriba et al., in prep

4Ω/π

Page 16: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Inferring Cross-Sections/ Diameters

( ) g

B

giIig mTk

ddpze

mm ππα 89

)8/1(/1 2++=

from Larriba et al., in prep

Singly Charged

Doubly Charged

•Solid line: Predicted curve with αI = 0.91, using known volumes of cation and anion as well as known volume fraction.

•Dashed line: Polarization Limit

•Excellent agreement (<1% difference between predictions and measurements)

•We therefore use αI = 0.91, dg = 0.3nm in inferring di from Z, z, measurements

Page 17: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Comparison to GEMMA Results• Prior DMA based protein measurements (pioneered by

Stan Kaufman)– Singly charged protein ions (5 kDa to several MDa)

•Black circles- This study

•White Squares-Kaufman et al., 1996

•Grey Triangles- Bacher et al., 2001 and Kaddis et al., 2007.

•Diameter ~ Mass1/3

•Kaufman Density: 0.89 g cm-3

•Bacher+Kaddis Density: 0.67 g cm-3

•This Study: 0.95 g cm-3

•Difference with Kaufman et al: attributable to solute adducts•Bulk peptide density: 1.35 g cm-3

•Kaddis+Bacher Denisty: Low

Page 18: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Comparison to Drift tube Results• Drift tube Measurements:

– Often used as standards for T-WAVE calibration (need to be extremely reliable)

– Made in He (~dg = 0.2 nm)

– Made from electrosprayed ions in acidic solution (or MALDI)

– Comparison of equivalent charge state ions (in terms of ion diameter):• Lysozyme+5:

– Clemmer and coworkers: 3.89 nm (αI=0), 3.37 nm (αI = 0.91)

– This study: 4.01-4.18 nm (αI=0), 3.40-3.54 nm (αI = 0.91)

– Fernandez-Lima et al. (2010, MALDI, +1 ion): 3.40 nm (αI=0), 2.89 (αI = 0.91)

• Cytochrome C+4

– Clemmer and coworkers: 3.63 nm (αI=0), 3.09 nm (αI = 0.91)

– This study: 3.85-4.00 nm (αI=0), 3.26-3.39 nm (αI = 0.91)

– Fernandez-Lima et al. (2010, MALDI, +1 ion): 3.34 nm (αI=0), 2.84 (αI = 0.91)

Page 19: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Summary & Conclusions• DMA-MS can be successfully employed to measure the

m/z and mobility of non-denatured electrospray-generated protein ions

• Charge reducing buffer mitigates the effects of Coulombic stretching and polarization

• Mobility measurements made immediately following droplet evaporation

• Despite solute clustering onto ions during measurements, relatively compact ions are found– Ion sizes inferred with αI = 0.91– Suggest further investigation of αI in He for di determination.

• Future work: further interpreting protein structure from DMA-MS measurements– GroEL: Partially collapsed gas-phase structure observed

Page 20: Mobility Measurement of Non- Denatured Protein and Protein Cluster … 2010 CJH... · 2010-07-08 · Mobility Measurement of Non-Denatured Protein and Protein Cluster Ions by DMA-MS

Acknowledgements

• DMA P4- supplied by SEADM, Boecillo, Spain

• QSTAR-XL Provided by Applied Biosystems

• Laboratory space provided by the Keck Biotechnology Center

• We thank Brandon Ruotolo, Joe Loo, and Bruce Andrien for visiting Yale University and providing unique protein samples to examine (most data not shown)