172 MK INSTALLATION AND USE Suitable for use with clean water and liquids that are not chemical- ly aggressive towards the materials from which the pump is made. The high efficiency and adaptability of these pumps to even the most unusual of applications, makes them ideal for use in the do- mestic, civil and industrial sectors; in particular for the distribution of water in combination with pressure sets and for pressure boost- ing. The pump should be installed in an enclosed environment, or at least sheltered from inclement weather . OPTIONALS AVAILABLE ON REQUEST • Suction and delivery ports with threaded anges in compiance with ISO 228/1 (1” - 1¼” - 1½) • Other voltages or 60 Hz frequency GUARANTEE 1yearsubject to terms and conditions PERFORMANCE RANGE • Flow rate up to 180 l/min(10.8 m³/h) • Head up to 103 m APPLICATION LIMITS • Manometric suction lift up to 7 m • Liquid temperature between -10 °Cand +40 °C • Ambient temperature up to +40 °C • Max. working pressure 10 bar • Continuous serviceS1 CONSTRUCTION AND SAFETY STANDARDS EN 60335-1 IEC 60335-1 CEI 61- 150 EN 60034-1 IEC 60034-1 CEI 2-3 CERTIFICATIONS Vertical multi-stage pumps
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
7242019 MK-bomba jockey
httpslidepdfcomreaderfullmk-bomba-jockey 14172
MK
INSTALLATION AND USE
Suitable for use with clean water and liquids that are not chemical-ly aggressive towards the materials from which the pump is madeThe high effi ciency and adaptability of these pumps to even themost unusual of applications makes them ideal for use in the do-mestic civil and industrial sectors in particular for the distributionof water in combination with pressure sets and for pressure boost-ingThe pump should be installed in an enclosed environment or atleast sheltered from inclement weather
OPTIONALS AVAILABLE ON REQUEST
bull Suction and delivery ports with threaded 1047298anges in compiance
with ISO 2281 (1rdquo - 1frac14rdquo - 1frac12) bull Other voltages or 60 Hz frequency
GUARANTEE
1 year subject to terms and conditions
PERFORMANCE RANGE
bull Flow rate up to 180 lmin (108 msup3h) bull Head up to 103 m
APPLICATION LIMITS
bull Manometric suction lift up to 7 m bull Liquid temperature between -10 degC and +40 degC bull Ambient temperature up to +40 degC bull Max working pressure 10 bar bull Continuous service S1
CONSTRUCTION AND SAFETY STANDARDS
EN 60335-1IEC 60335-1
CEI 61-150
EN 60034-1IEC 60034-1
CEI 2-3
CERTIFICATIONS
Vertical multi-stage pumps
7242019 MK-bomba jockey
httpslidepdfcomreaderfullmk-bomba-jockey 24173
0 20 40 60 80 100 120 140 160 18010
20
30
40
50
60
70
80
90
100
1100 10 20 30 40
0 10 20 30 40
50
100
150
200
250
300
350
0 1 2 3 4 5 6 7 8 9 10 11
US gpm
Imp gpmfeet
lmin
msup3h
MK58MK38
MK37
MK36
MK35
MK34
MK85
MK84
MK86MK57
MK56
MK55
MK54
Flow rate Q
H e a
d H ( m e t r e s )
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 1min HS= 0 m
MKm 35 60 A 58 A 120 AMKm 36 65 A 63 A 130 AMKm 37 70 A 68 A 140 AMKm 38 90 A 87 A 180 AMKm 54 65 A 63 A 130 AMKm 55 85 A 82 A 170 AMKm 56 95 A 91 A 190 AMKm 57 105 A 102 A 210 AMKm 58 115 A 110 A 230 AMKm 84 85 A 82 A 170 AMKm 85 95 A 91 A 190 AMKm 86 115 A 110 A 230 A
MODEL VOLTAGE (three-phase)
Three-phase 230 V 400 V 690 V 240 V 415 V 720 VMK 34 35 A 20 A 12 A 34 A 20 A 12 AMK 35 42 A 24 A 14 A 40 A 23 A 13 AMK 36 48 A 28 A 16 A 46 A 27 A 16 AMK 37 52 A 30 A 17 A 50 A 29 A 17 AMK 38 55 A 32 A 18 A 53 A 31 A 18 AMK 54 48 A 28 A 16 A 46 A 27 A 16 AMK 55 52 A 30 A 17 A 50 A 29 A 17 AMK 56 61 A 35 A 20 A 58 A 34 A 20 AMK 57 78 A 45 A 26 A 75 A 43 A 25 AMK 58 87 A 50 A 29 A 83 A 48 A 28 AMK 84 52 A 30 A 17 A 50 A 29 A 17 AMK 85 61 A 35 A 20 A 58 A 34 A 20 AMK 86 87 A 50 A 29 A 83 A 48 A 28 A
7242019 MK-bomba jockey
httpslidepdfcomreaderfullmk-bomba-jockey 24173
0 20 40 60 80 100 120 140 160 18010
20
30
40
50
60
70
80
90
100
1100 10 20 30 40
0 10 20 30 40
50
100
150
200
250
300
350
0 1 2 3 4 5 6 7 8 9 10 11
US gpm
Imp gpmfeet
lmin
msup3h
MK58MK38
MK37
MK36
MK35
MK34
MK85
MK84
MK86MK57
MK56
MK55
MK54
Flow rate Q
H e a
d H ( m e t r e s )
CHARACTERISTIC CURVES AND PERFORMANCE DATA 50 Hz n= 2900 1min HS= 0 m
MKm 35 60 A 58 A 120 AMKm 36 65 A 63 A 130 AMKm 37 70 A 68 A 140 AMKm 38 90 A 87 A 180 AMKm 54 65 A 63 A 130 AMKm 55 85 A 82 A 170 AMKm 56 95 A 91 A 190 AMKm 57 105 A 102 A 210 AMKm 58 115 A 110 A 230 AMKm 84 85 A 82 A 170 AMKm 85 95 A 91 A 190 AMKm 86 115 A 110 A 230 A
MODEL VOLTAGE (three-phase)
Three-phase 230 V 400 V 690 V 240 V 415 V 720 VMK 34 35 A 20 A 12 A 34 A 20 A 12 AMK 35 42 A 24 A 14 A 40 A 23 A 13 AMK 36 48 A 28 A 16 A 46 A 27 A 16 AMK 37 52 A 30 A 17 A 50 A 29 A 17 AMK 38 55 A 32 A 18 A 53 A 31 A 18 AMK 54 48 A 28 A 16 A 46 A 27 A 16 AMK 55 52 A 30 A 17 A 50 A 29 A 17 AMK 56 61 A 35 A 20 A 58 A 34 A 20 AMK 57 78 A 45 A 26 A 75 A 43 A 25 AMK 58 87 A 50 A 29 A 83 A 48 A 28 AMK 84 52 A 30 A 17 A 50 A 29 A 17 AMK 85 61 A 35 A 20 A 58 A 34 A 20 AMK 86 87 A 50 A 29 A 83 A 48 A 28 A
MKm 35 60 A 58 A 120 AMKm 36 65 A 63 A 130 AMKm 37 70 A 68 A 140 AMKm 38 90 A 87 A 180 AMKm 54 65 A 63 A 130 AMKm 55 85 A 82 A 170 AMKm 56 95 A 91 A 190 AMKm 57 105 A 102 A 210 AMKm 58 115 A 110 A 230 AMKm 84 85 A 82 A 170 AMKm 85 95 A 91 A 190 AMKm 86 115 A 110 A 230 A
MODEL VOLTAGE (three-phase)
Three-phase 230 V 400 V 690 V 240 V 415 V 720 VMK 34 35 A 20 A 12 A 34 A 20 A 12 AMK 35 42 A 24 A 14 A 40 A 23 A 13 AMK 36 48 A 28 A 16 A 46 A 27 A 16 AMK 37 52 A 30 A 17 A 50 A 29 A 17 AMK 38 55 A 32 A 18 A 53 A 31 A 18 AMK 54 48 A 28 A 16 A 46 A 27 A 16 AMK 55 52 A 30 A 17 A 50 A 29 A 17 AMK 56 61 A 35 A 20 A 58 A 34 A 20 AMK 57 78 A 45 A 26 A 75 A 43 A 25 AMK 58 87 A 50 A 29 A 83 A 48 A 28 AMK 84 52 A 30 A 17 A 50 A 29 A 17 AMK 85 61 A 35 A 20 A 58 A 34 A 20 AMK 86 87 A 50 A 29 A 83 A 48 A 28 A
MKm 35 60 A 58 A 120 AMKm 36 65 A 63 A 130 AMKm 37 70 A 68 A 140 AMKm 38 90 A 87 A 180 AMKm 54 65 A 63 A 130 AMKm 55 85 A 82 A 170 AMKm 56 95 A 91 A 190 AMKm 57 105 A 102 A 210 AMKm 58 115 A 110 A 230 AMKm 84 85 A 82 A 170 AMKm 85 95 A 91 A 190 AMKm 86 115 A 110 A 230 A
MODEL VOLTAGE (three-phase)
Three-phase 230 V 400 V 690 V 240 V 415 V 720 VMK 34 35 A 20 A 12 A 34 A 20 A 12 AMK 35 42 A 24 A 14 A 40 A 23 A 13 AMK 36 48 A 28 A 16 A 46 A 27 A 16 AMK 37 52 A 30 A 17 A 50 A 29 A 17 AMK 38 55 A 32 A 18 A 53 A 31 A 18 AMK 54 48 A 28 A 16 A 46 A 27 A 16 AMK 55 52 A 30 A 17 A 50 A 29 A 17 AMK 56 61 A 35 A 20 A 58 A 34 A 20 AMK 57 78 A 45 A 26 A 75 A 43 A 25 AMK 58 87 A 50 A 29 A 83 A 48 A 28 AMK 84 52 A 30 A 17 A 50 A 29 A 17 AMK 85 61 A 35 A 20 A 58 A 34 A 20 AMK 86 87 A 50 A 29 A 83 A 48 A 28 A