Top Banner

of 8

Minimet Brochure

Apr 06, 2018

Download

Documents

melancholy2
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • 8/3/2019 Minimet Brochure

    1/8

    e n v i r o n m e n t a l a n d b o t a n i c a l i n s t r u m e n t a t i o n

    Automatic Weather Station

    Meteorology

    Data Display

    Remote Data Collection

    MiniMet

  • 8/3/2019 Minimet Brochure

    2/8

    Pest & Disease Forecasting

    Commercial Growers

    Horticulture

    Plant Research

    Animal Studies

    Agronomy

    Agricultural & Crop Research

    Yield & Harvest Prediction

    Sunshine Hours

    Degree Days

    Megajoules per Day

    Irrigation SchedulingSkyeLynx Standard

    Supplied free with all systems. An

    easy-to-use program forcommunicating with your MiniMet

    SkyeLynx AutoAutomatically connects with yourMiniMet and downloads the data

    at pre-set times. Data isautomatically stored in a file on

    your PCUp to 25 MiniMets can be

    accessed by the program, thesettings for each are stored inindividual instrument profiles

    Automatic Weather

    with

  • 8/3/2019 Minimet Brochure

    3/8

  • 8/3/2019 Minimet Brochure

    4/8

    The Skye MiniMet is a modularmulti- channel weather station for

    environmental monitoringChoose only the sensors you need -

    up to 12

    Ready configured on arrival. Nocomplicated setup routines. Sensors

    just plug in - no complicatedwiring up

    Choice of communicationlinks including GSMcellular phone

    Extremely portable which makes theMiniMet ideal for short-term

    research or monitoring projects

    Supplied with SkyeLynx Standard,an easy-to-use communications

    package for offloading data as asimple ASCII file. This can then be

    imported into commercialspreadsheet packages

    Optional softwares offered areSkyeLynx Auto for automaticallydownloading data at preset times,and SkyeLynx Deluxe, a powerful

    graphing program

    Compatible with many 3rd partysoftware programs

    Features a real-time clock andconventional calendar. Readingscan be synchronised with other

    stations

    MiniMet is completely weatherproofand no extra enclosures are required

    Low cost with no hiddenextras, yet utilises precision

    components and sensors

  • 8/3/2019 Minimet Brochure

    5/8

    DATA LOGGERThe heart of the MiniMet and mounted on a bracket. Other sensors plug intothis enclosure

    ANEMOMETERA highly sensitive and robust instrument, yet small and light weight.Low threshold speed and good repeatability

    WIND VANELow threshold for sensitivity at low wind-speeds. Robust bearings forlong life

    PYRANOMETER SENSOR - (Total Solar Radiation)PAR QUANTUM SENSOR, UVA, UVB, UVI SENSORSHighly specified sensors with excellent long-term stability. Cosine- corrected sothat reliable, repeatable measurements are obtained which can be compared withother sensors

    BAROMETER (AIR PRESSURE SENSOR)A high quality transducer, robust and reliable. Choice of two models

    SOIL TEMPERATURE PROBESimple yet very precise method of measuringthis parameter

    SURFACE WETNESS SENSORGold-plated for minimum corrosion

    TENSIOMETERAccurate method of determining

    the moisture content of the soil

    Plus Your Choice of Sensors

    RELATIVE HUMIDITY & AIR TEMPERATURESensing elements are located within the protecting screen, so that airhumidity & temperature are measured without the effect of the sun. Dishesof the screen are designed so that reflected heat from the ground or othersources is not measured

    RAINGAUGEUses the well-documented

    tipping bucket type.

  • 8/3/2019 Minimet Brochure

    6/8

    ...... with a GSM modem link

    This option can give you 24 hour access to your Skye Software to call up your MiniMet. A single clickmeteorological data from anywhere in the world. With of the mouse will initiate the call to your weatherthe addition of the SkyeLynx Auto software, the whole station and once the call is connected, you can use allroutine can be completely automated. the functions of your weather station as though you

    were sitting next to it - offload data, clear memory, alterThe Skye GSM link uses Vodafone, T-Mobile or Orange

    setup parameters etc.digital mobile 'phonenetworks in the UK to permit Unfortunately, a mobile phone requires rather morethe control and offloading data power than to run the MiniMet itself. But in mostfrom MiniMet weather applications enough power is available from a smallstations. Overseas systems solar panel for self-contained auto-simply require a GSM network rechargewith a data service.

    The GSM Link has electronics built inA major advantage of this type to protect the system from low powerof installation is that the and power loss situations. If a solarMiniMet station can be panel is not appropriate and mainsentirely remote from the user,

    power is not available, then operationand there can be more than times are maximised by use of aone user contacting the station. switch on' device for the modemFor example the MiniMet could within the Skye GSM link electronics.be in Wales, but it could be This facility switches on the modemtelephoned from 2 miles away, for a user selected period.200 miles away or 2, 000 milesaway (provided there is acellular phone signal at the MiniMet site).

    Operation is very simple. A standard hardwaremodem is required in your PC and this is used by the

    COMMUNICATING WITH YOUR MINIMET

    ...... with a laptop PCVisit the MiniMet and connect the data-lead, which is supplied with the system,between the RS232 socket on the MiniMet and your laptop. The SkyeLynx Standardsoftware, which is also supplied with the system, is then run and you are able to

    download data and change the setup if you wish.

    ...... with a permanent cable linkThis option is popular in sites where there is a mains power supply available and thedistance between the MiniMet and the desktop PC is no more than 1km. It is oftenpreferable to bury the cable, as small mammals find cables very tasty to eat!

    ...... with a line-modem linkIdeal if there is a mains power supply and telephone point available at the MiniMet

    site, and users wanting to contact the weather station live many miles away A usefuloption for multi-user access.

  • 8/3/2019 Minimet Brochure

    7/8

    MINIMET SPECIFICATIONS

    The System

    Datalogger Housing

    Connections

    Power

    ResolutionCommunications

    Memory

    Sample & Logging TimesModes

    30 Minute Records 24 Hour summaries

    Clock

    Sensor Choice

    Operating range

    Relative Humidity, Air temperature, Solar Radiation (Pyranometer), Windspeed, Wind direction, Rainfall, AirPressure, Soil Temperature, Tensiometers, Surface Wetness, PAR Quantum, UVA, UVB, UVIUp to a maximum of 12 channels. Sensors can be added at a later date20 to +70C. Storage -35 to +70C.

    Grey ABS sealed to IP 65

    Dimensions 120 x 120 x 105mm.Binder subminiature type 8 and 5 pin. Sealed to IP 65 when mated with a plug or blanking cover (cover forRS232 port supplied as standard)Standard units have 6 x 'C' cell batteries giving a typical 4-6 month battery life. Solar power/mainspower options are available to extend battery life, depending on the system chosen15 bits A/D Converter

    Storage in battery backed RAM capacity for up to 27,000 recordings (depending on number of channels beingmeasured) plus time of data being recorded as standard. Channels can be on or off as required. 1Mbit RAM

    The MiniMet is supplied "ready-to-go". It is set in a standard 'default operating mode, but the user may at any timereconfigure the channels and the measuring/recording intervals.

    Date & Time. Location I/D Date/Time, Location I/DMean Air Temperature Average/maximum, minimumMean Relative Humidity Air temperatureMean Solar Radiation Relative HumidityMean Wind Speed Wind SpeedMean Wind Direction Wind DirectionRainfall in last hour Pressure

    Solar RadiationTotal rainfall

    All units have a real time clock to synchronise the timing of readings between several MiniMets.

    -

    RS232C will connect to any computer type with RS232 and communications software via a direct cable link or modem.. Units are supplied with a cable suitable for connection to the communications port of any IBM PC or compatible

    computer). All units are supplied with the "SkyeLynx Standard communications program

    Each channel can be individually configured from a choice of 10 seconds up to 12 hour intervals including averaging

    POWER SUPPLY OPTIONS

    BATTERY POWER (Standard Option)

    SOLAR POWER (Optional)

    MAINS POWER (Optional)

    Skye MiniMet loggers are fitted with Duracell alkaline batteries as standard. These will have a lifetime of 4-6 monthsdepending on operating temperature, frequency of logging and data download. These batteries are an operationalpower source only, all data and logger configuration is stored by a lithium battery backed RAM chip, unaffected bythe state of the operational power supply.

    The ACC/5 Solar Hog solar power supply is designed for use with a MiniMet logger. It consists of a small solarpanel, trickle rechargeable batteries, waterproof enclosure and pole mount and fixings. (The pole mount can be boltedto a wall or vertical surface if preferred.) The Solar Hog powers the logger through the RS232 socket and so has itsown RS232 socket for downloading data without interruption of the power supply. This option is ideal for remoteinstallations visited occasionally for download with a laptop PC.If the GSM system is purchased then a larger solar power option replaces the ACC/5 Solar Hog

    a) Maximum 50m distance between mains supply and loggerThe ACC/9 Mains Hog consists of a voltage transformer which runs off mains power (please specify 110V or 220V)and provides a 12V supply to the logger. The Mains Hog itself is installed indoors (for safety reasons) and only the12V power cable runs outdoors to the logger. This cable has 2 purposes, to take the 12V power to the logger, and alsoto act as a data transfer cable. The 12V cable plugs into the logger's RS232 socket (the logger's internal alkalinebatteries remain installed to provide backup in case of power failure). The indoor Mains Hog also has a RS232 socketwhich connects to the PC, (using the standard data cable supplied with the logger) for data transfer. This means thatthe logger can be easily accessed from the PC at any time.B) Maximum 1km distance between mains supply and loggerThe ACC/9B Mains Hog with Signal Boosters is similar to the standard Mains Hog but also has provisions forovercoming low data signals and voltage drop over long cable lengths. In this case the Mains Hog has rechargeablebatteries fitted to provide back up in case of power failure, and the logger's internal alkaline batteries are removed.The Mains Hog is again installed indoors next to a PC plus a second unit is located out at the logger installation(which plugs into the logger's RS232 socket) to provide a boost to the return data signals. The dual purpose power /

    data cable runs between the two as before.

  • 8/3/2019 Minimet Brochure

    8/8

    environmental and botanicalinstrumentation

    T H O U S A N D S O FC U S T O M E R S I N O V E R O N E

    H U N D R E D C O U N T R I E S

    Skye is a family run companyand since 1983 has been exporting

    instruments to nearly every country

    in the world. We pride ourselves on

    customer care and our flexibility

    when it comes to providing the

    customer with what they need.

    Uni t s des igned and bu i l t i n Wa les

    ACCESSORIESRadiation screen for RH/Temperature (SKRS 085S, SKRS 085D)

    Levelling Unit and pole mount for Light Sensor (SKM 221/226)

    Dual arm pole mount for wind sensors (ACC/12)

    Levelling base plate for Raingauge (RGB1)

    MAST

    UV stable ASA white polymer plus "V" bolts for fixing to pole

    Levelling Unit: anodised aluminium with plastic fixingsPole Mount: Stainless steel painted gloss white with "Vbolts for fixing to pole

    Aluminium painted gloss white

    1All of the sensors offered for use with the MiniMet are designed to mount on a 1 / " (38mm)2diameter mast, except for the raingauge which is mounted near the base of the MiniMet mast.To accommodate individual customers needs in the best way, several mast options are offered -please enquire.

    Aluminium base plate with stainless steel and plastic fasteners

    YOUR CHOICE OF MINIMETSSDL 5200SDL 5250SDL 5300SDL 5350SDL 5400SDL 5450

    YOUR CHOICE OF SENSORS FOR THE MINIMETRELATIVE HUMIDITY (SKH 2060/I, SKH 2065/I, SKH 2070/I)Housing

    Sensor typeMeasurement rangeResolution /accuracyAIR TEMPERATURE

    Housing

    LIGHT SENSORSPYRANOMETER (SKS 1110/I), QUANTUM (SKP 215/I) , UVA(SKU 420/I) , UVB(SKU 430/I),

    UVI (SKU 440/I)HousingDetectorAccuracyCalibration

    ANEMOMETER (Windspeed) (A100R/I)HousingStarting Speed (Threshold)Maximum WindspeedAccuracyWIND VANE (Wind Direction) (W200P/D1/I)HousingAccuracy

    RAINGAUGE(ARG 100/I or 10000E/I)

    HousingTypeTip SensitivityAIR PRESSURE (SKPS 800/I)RangeResolution / error

    SOIL TEMPERATURE PROBE (SKTS 200/I)Housing

    SensorResolution / accuracyTENSIOMETER (SKT 600 - 650/I)Measurement Range

    Shaft LengthSensor TypeLong-term StabilitySURFACE WETNESS SENSOR(SKLW 1900/I)

    4 sensors5 sensors6 sensors7 sensors8 sensors9 sensorsPlease contact Skye if you require a MiniMet for 10 sensors or more

    Mounted in a machined PTFE head located at the top of a painted

    aluminium tube. Protected from dust particles, etc. by 32 micronstainless steel gauze. (Optional cover for protection against smallerparticles e.g. Salt spray or dust)Capacitive silica substrate, chrome alloy electrodes0-100% (at -20 to +70C)Resolution: 0.1% Accuracy: 2% maximum typical 1% or better

    Precision 10k thermistor (Fenwal) sealed to IP67. Low thermal mass.Resolution: 0.01C Accuracy: 0.2 at 25C ORPrecision PT100 fully sealed to IP67Resolution: 0.01C Accuracy: 0.15Located alongside the humidity sensing element to measuretemperature of the same air sample as RH% measurements

    Fully sealed to IP68. Cosine-correctedSilicon, GaP or GaAsP5% maximum, typical 3% or better

    Resolution b Absolute error at 20C and1000mbar t Error over 0-50C, typically 1.5 bar (maximum 3.6mbar)

    Resolution Accuracy

    0-850 hPa (0-850mbar)

    Against transfer standard thermocouple traceable to NPL &UK Met. Office standards

    Anodised aluminium alloys, stainless steel and weather resistant plastics0.3m/sOver 75m/s

    2% + 0.1m/s

    Anodised aluminium alloy and stainless steel2% obtainable in steady winds over 5m/s

    Vacuum formed from UV resistant plastic or anodised aluminiumTipping bucket0.2mm of rain as standard - 0.1mm and 0.5mm also available

    500mbar to 1050mbaretter than 0.1mbar.

    ypically 0.5mbar (maximum 1.0mbar).

    Sensor located at the end of a 3m length of screened cable andcompletely sealed against water ingressPrecision 10K thermistor (Fenwall) sealed to IP68

    0.01C. Less than 0.2 error at 25C

    User definedLow pressure transducer, stabilised for temperature & linearity0.1% typically