Top Banner
Characteristics & Advantages Ⅰ. Features Fixture / Cover Screw & Healing Abutment MiNi Overdenture Fixture Abutment Prosthetic Options Ⅰ. Fixture level prosthesis Ⅱ. Overdenture Prosthesis 1. Meg-Rhein Abutment & Components 226 226 226 226 228 230 230 234 Key advantages Strong solution for narrow ridge & Anterior small teeth. Mini, but mighty. MiNi Product coodinator : June Park, [email protected]
28

MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

Apr 07, 2018

Download

Documents

vuongduong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

Characteristics & AdvantagesⅠ. Features

Fixture / Cover Screw & Healing Abutment

MiNi Overdenture Fixture

Abutment Prosthetic OptionsⅠ. Fixture level prosthesisⅡ. Overdenture Prosthesis

1. Meg-Rhein Abutment & Components

226

226

226

226

228

230

230

234

Key advantages➲ Strong solution for narrow ridge & Anterior small teeth.➲ Mini, but mighty.

MiNi™

Product coodinator : June Park, [email protected]

Page 2: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

226

(unit : mm)

Mechanical test using universal testing machine in accordance with ISO 14801,-R&D center in MegaGen Implant Co.,Ltd.(2013)-

Parallelwall thickness

MiNiTM

Ø3MiNiTM

Ø3.25Company A

Ø3

A 0.28 0.47 0.34

B 0.31 0.42 0.44

11˚connection

M1.4Abutment Screw

XPEEDSurface treatment

1.7mm Hex

Knife thread

MiNiTM, but mighty- When compared with the company A, MiNiTM internal fixture Ø3.0 has similar compressive strength, but Ø3.25 fixture showed much higher value of strength on the thin wall area of the fixture.

Company AØ3.0

Company AØ3.0

MiNiTM

Ø3.0

MiNiTM

Ø3.0

MiNiTM

Ø3.25

MiNiTM

Ø3.25

Ø3.0Ø3.0 Ø3.4

676.6

Load

(N)

500

550

650

600

700

750

800

657.1

784.4

AA A

B BB

[Compressive Strength]

[Wall Thickness]

Characteristics & Advantages » Ⅰ. Features

Ⅰ. FeaturesCharacteristics & Advantages

• Do not use Torque Wrench.• Max uniform strength of hex 50Ncm.• Can not exceed 75Ncm.

Page 3: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

MiNi – 227

MiNi Fixture- Cover Screw included

• PlatformdiameterofØ3.0fixtureis3.0mm.• PlatformdiameterofØ3.25fixtureis3.4mm.

Ø3.0

8.5 MIIF3008C

10.0 MIIF3010C

11.5 MIIF3011C

13.0 MIIF3013C

15.0 MIIF3015C

Ø3.25

8.5 MIIF3308C

10.0 MIIF3310C

11.5 MIIF3311C

13.0 MIIF3313C

15.0 MIIF3315C

L

L

Length(mm)Diameter Ref.C

Ø3.25

Ø3.4

Ø3.0

Cover Screw• Recommend torque : by hand (5 - 8Ncm).• Onlywithfingerforce.

0.5 MICS2505

Height(mm) Ref.C0.5

Top view

Healing Abutment• Recommend torque : by hand (5 - 8Ncm).• Onlywithfingerforce.

Ø3.0

2.5 MIHA3025

3.0 MIHA3030

4.0 MIHA3040

5.0 MIHA3050

6.0 MIHA3060

Ø3.5

2.5 MIHA3525

3.0 MIHA3530

4.0 MIHA3540

5.0 MIHA3550

6.0 MIHA3560

Height(mm)ProfileDiameter Ref.C

H

H

Fixture / Cover Screw & Healing Abutment

Fixture / Cover Screw & Healing Abutment

Page 4: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

228

MiNi Overdenture Fixture

MiNi Overdenture Fixture

Ø2.5 2

8.5 OF25208

10 OF25210

11.5 OF25211

13 OF25213

Ø2.5 4

8.5 OF25408

10 OF25410

11.5 OF25411

13 OF25413

Ø3.0 2

8.5 OF30208

10 OF30210

11.5 OF30211

13 OF30213

Ø3.0 4

8.5 OF30408

10 OF30410

11.5 OF30411

13 OF30413

Ø3.5 2

8.5 OF35208

10 OF35210

11.5 OF35211

13 OF35213

Ø3.5 4

8.5 OF35408

10 OF35410

11.5 OF35411

13 OF35413

L

C.H

Diameter Length(mm) Ref.C

D

MiNi Overdenture Fixture• 2.5 / 3.0 / 3.5mm of diameter and 2.0 / 4.0mm with

8.5 / 10.0 / 11.5 / 13.0mm in length, it is easy to use in any circumstance. (100% compatible with Rhein83)

Cuff Height(mm)

▸▸ Product Concept

1. Fast osseointegration for thanks to our S-L-A surface treatment2. Excellent for maxillary lateral incisor and mandible anterior3. Easy-to-use, intuitive operation procedure4. Excellent esthetical design5. Minimize drilling sequence with 1-step insertion

Page 5: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

MiNi – 229

Ø2.0

33 SD2018S

38 *SD2018M

43 *SD2018L

Ø2.5

33 SD2518S

38 *SD2518M

43 *SD2518L

Ø2.8

33 SD2818S

38 *SD2818M

43 *SD2818L

Diameter Length(mm) Ref.C Ø2.5Ø2.0 Ø2.8

(*) Separate sales item.

Ø1.8

33 ID1818S

38 *ID1818M

43 *ID1818L

Initial Drill• Used to pierce the cortical bone initially. • Advisable to go into the bone to the full length ofafixture.

Handpiece Connector

Ratchet Connector

Shaping Drill• Each drill has depth marking lines from 7.0mm

to 15.0mm.• The dual marking system(grooves and laser

markings) provides visual and radiographic depth verificationduringsurgery.

• TiN coating on drills : Enhanced corrosion resist-ance and abrasion resistance.

(*) Separate sales item.

Diameter Length(mm) Ref.C

Short OHCS

Type Ref.C

Short 12 ORCS

Type Length(mm) Ref.C

➲ MiNi Overdenture Components

MiNi Overdenture Fixture

Page 6: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

230

EZ Post Abutment

TemporaryAbutment

Impression Coping(Transfer)

Impression Coping(Pick-up)

Cover Screw

Lab Analog

Closed tray Open tray

Milling Abutment

FuseAbutment

Healing Abutment

Angled Abutment

Ⅰ. Fixture Level Prosthesis

Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

Abutment & Prosthetic Options

Page 7: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

MiNi – 231

Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

➲ Abutment Options & Components (Continued)

Impression Coping- Guide Pin included

• Guide Pin (Transfer type - MIGPT16 Pick-up type - MIGPP16)

• Transfer type : Should be tightened with Impression Driver (Page.277)

Special Guide Pin which can be used with a 1.2mm hex driver is available on request.

Ø3.5

12Transfer

Hex

MIIT3512HT

Pick-up MIIP3512HT

16Transfer MIIT3516HT

Pick-up MIIP3516HT

ProfileDiameter

Length(mm) Ref.CType

Transfer type Pick-up type

1416

Ø3.5 Ø3.5

Lab Analog12 MILA300H

Length(mm) Ref.C12

Temporary Abutment- Abutment Screw(MIAS14) included

• Recommend torque : 10 - 15NcmØ3.0 12 Hex MITA3012HT

ProfileDiameter Length(mm) Ref.CType 12

Ø3.0

Page 8: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

232

➲ Abutment Options & Components

Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

EZ Post Abutment- Abutment Screw(MIAS14) included

• Recommend torque : 15Ncm

Ø3.5

5.0

1.0 MIEP3505HT

1.5 MIEP3515HT

2.5 MIEP3525HT

3.5 MIEP3535HT

4.5 MIEP3545HT

7.0

1.0 MIEP3507HT

1.5 MIEP3517HT

2.5 MIEP3527HT

3.5 MIEP3537HT

4.5 MIEP3547HT

9.0

1.0 MIEP3509HT

1.5 MIEP3519HT

2.5 MIEP3529HT

3.5 MIEP3539HT

4.5 MIEP3549HT

ProfileDiameter

PostHeight(mm)

Cuff Height(mm) Ref.C

C.H5

7

7 8

9

P.D

Fuse Abutment- Abutment Screw(MIAS14) + Fuse Cap included

• Recommend torque : 10 - 15Ncm• For the design concept and rationale of the

Fuse Abutment, please refer to Page.084

Ø5.0 Ø3.5 3.5 7.0Straight MFAP3535P

Angled(15°) MFAA3315P

C.H(mm)

P.H(mm) Ref.CTypeLabio-

lingualMesio-distal

15°

Mesio-distal

Mesio-distal

Labio-lingual

Labio-lingual

P.H

C.H

Page 9: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

MiNi – 233

Abutment & Prosthetic Options » Ⅰ. Fixture Level Prosthesis

Angled Abutment- Abutment Screw(MIAS14) included

• Recommend torque : 15Ncm

C.H C.H

Ø3.5 Ø3.5

15° 15°

Ø3.5

2.5

Hex

15°

MIAA3215HT

3.5 MIAA3315HT

4.5 MIAA3415HT

2.5

Hex-E

MIAA3215ET

3.5 MIAA3315ET

4.5 MIAA3415ET

ProfileDiameter Type AngleCuff Height

(mm) Ref.C

Hex Hex-E

7 8

Milling Abutment- Abutment Screw(MIAS14) included

• Recommend torque : 15Ncm

Ø3.0

5.0

1.0 MIMA3005HT

1.5 MIMA3015HT

2.5 MIMA3025HT

3.5 MIMA3035HT

4.5 MIMA3045HT

7.0

1.0 MIMA3007HT

1.5 MIMA3017HT

2.5 MIMA3027HT

3.5 MIMA3037HT

4.5 MIMA3047HT

9.0

1.0 MIMA3009HT

1.5 MIMA3019HT

2.5 MIMA3029HT

3.5 MIMA3039HT

4.5 MIMA3049HT

ProfileDiameter

PostHeight(mm)

Cuff Height(mm) Ref.C

C.H5

7

9

Ø3.0

Page 10: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

234

Retentive Cap Set

Lab Analog

Impression Coping

Meg-Rhein Abutment

Ⅱ. Overdenture Prosthesis 1. Meg-Rhein Components

Abutment & Prosthetic Options » Ⅱ. Overdenture Prosthesis

Page 11: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

MiNi – 235

Abutment & Prosthetic Options » Ⅱ. Overdenture Prosthesis

Advantage

*Smaller & more convenient than others, with proven Italian technology.

Product K & L

Product P

Meg-Rhein

4.4mm

2.1mm

2.25mm

2.3mm

5.5mm

5.2mm

30º

Violet(2.7kg)

White(1.8kg)

Pink(1.2kg)

Yellow(0.6kg)

* Seperate purchase available upon request

1. Small & Easy-to-use Housing System

2. Tilting Angle & Various Retentive Caps of the Meg-Rhein

3. Low Reduction Rate & Uniform Variance of Retentive Force

100

80

60

40

20

0Meg-Rhein Product K

Before After (1,000cycles)

Product L Product P

Ret

entiv

e fo

rce

(kg)

3

2

1

01,000 Cycles

R2=0.85

27%

7349%

51

38%

62

37%

63

R2(Coefficient of determination) becomes more reliable when it is close to “1”.

➲ Meg-Rhein Overdenture System

▸▸ Overdenture System

0 MDR00P

1.0 MDR01P

2.0 MDR02P

3.0 MDR03P

4.0 MDR04P

5.0 MDR05P

6.0 MDR06P

Cuff Height (mm) Ref.C

C.H

Meg-Rhein Overdenture System- 1 Meg-Rhein Abutment- 1 Plastic Carrier- 1 Stainless Steel Housing- 1 Protective Disk- 5 Retentive Caps (Black-Lab, Yellow-0.6kg, Pink-1.2kg, White-1.8kg, Violet-2.7kg)

• Perfect compatibility with the Rhein83 from Italy.• Recommend torque : 15Ncm.

Stainless Steel Housing & Black Cap

Yellow Cap & Pink Cap

White Cap & Violet Cap

Protective Disk

8.8

Meg-Rhein Abutment with Plastic carrier

Page 12: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

236

Abutment & Prosthetic Options » Ⅱ. Overdenture Prosthesis

5 Stainless Steel Housing• 5ea/pack

MHP

Ref.C

➲ Components for Meg-Rhein Abutment

RCVP

Ref.C 5 Retentive Caps (Violet)• Violetcap(2.7kg)-Forrefill(5ea/pack).• Can be used for more retentive force following

white cap(1.8kg).

RCPP

Ref.C 5 Retentive Caps (Pink)• Pinkcap(1.2kg)-Forrefill(5ea/pack).

RCYP

Ref.C 5 Retentive Caps (Yellow)• Yellowcap(0.6kg)-Forrefill(5ea/pack).

RCBP

Ref.C 5 Retentive Caps (Black)• For laboratory

RCWP

Ref.C 5 Retentive Caps (White)• Whitecap(1.8kg)-Forrefill(5ea/pack).• Can be used for more retentive force following pink

cap(1.2kg).

Page 13: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

MiNi – 237

Abutment & Prosthetic Options » Ⅱ. Overdenture Prosthesis

Stainless Impression Coping (Pick-Up)• 2ea/pack.• Italy - Rhein 83 products.• For accurate (pick-up type) impression.• Metal with groove design to prevent from swaying.

044CAIN

Ref.C 5.5

085IAC

Ref.C

83

40

Retentive Cap Insertion Tool• Retentive Cap insertion tool.

091EC

Ref.C

90

Retentive Cap Removal Tool• Retentive Cap removal tool.

PLA

Ref.C Lab Analog

Page 14: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

238

Fig 1. Intra-oral initial situation, front view

Fig 2. DSD analysis. The yellow dotes shows where the right canine should be moved for better smile outcome

Fig 3. Details of incision design. Front view

Fig 4. Final Drills in sites, front view. Flap was elevated and two osteotomy sockets were made for 3.0 mm Mini fixtures.

Fig 5. Implant placement on site # 22. There was enough bone left labio-lingually even at this thin ridge. There was no bone defect.

Fig 6. Occlusal view of the placed implants, 0.5 mm sub-crestally. Two 3.0*13mm MiNi implants were placed with excellent primary stability.

Fig 1

Fig 1

Fig 3 Fig 4

Fig 6Fig 5

Clinical Case

➲ Clinical Case - Courtesy of Dr. Achraf Souayah

MiNi Clinical Case

Page 15: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

MiNi – 239

Fig 7 Fig 8

Fig 10

Fig 13

Fig 14

Fig 11

Fig 9

Fig 12

Clinical Case

Fig 7. Sutured implant sites. Frontal view

Fig 8. Sutured implant sites, occlusal views & Post-operative retro-alveolar radiographs

Fig 9. Healed sites at 2 months recall, occlusal view

Fig 10. Different views of the copings placed over the EZ Post Abutments

Fig 11. Views of the temporary crowns with clean margins and concave buccal contour

Fig 12. Clinical photo of the intra-oral solidarization of the prefabricated teeth to the copings

Fig 13. Clinical photo immediately after temporary crown cementation. Notice the vertical position of the gingival margins of the laterals.

Fig 14. Temporary smile of the patient immediately after temporay cementation of the provisionals.

Page 16: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

Palatal Denture Stabilizer™

Page 17: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

Characteristics & AdvantagesI. Design Concept

Fixture ProductI. Size

Abutment & Prosthetic OptionsI. Overdenture Prosthesis

1. Meg-Rhein Components

Surgical Kit

Key advantages➲ Implants which can be placed in palatal side➲ Self tapping

Palatal Denture Stabilizer™

Product coodinator : Hyun wook An, [email protected]

242

242

243

243

244

248

Page 18: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

– 243242

▲ Soft tissue line

▲ Bone line

Why we need Palatal Denture Stabilizer?Maxillary arch is the most common area for ridge augmentation or bone graft.When there procedures are done, direct pressure on the surgical site can result wound dehiscence and / or movement of bone graft. So it is recommended not to use a temporary denture, which is really unacceptable from patients.Palatal Denture Stabilizer can support excellent stabilization for a temporary denture, even with relief on the surgical area.And also, it can be useful for the stabilization of a permanent loose denture caused by various reasons.

What is Palatal Denture Stabilizer?It is a MegaGen’s Unique Development for the stabilization of upper denture.

How Palatal Denture Stabilizer is Possible?The palatal process of Maxillary bone is most stable structure which does not change for life-time, even with long term use of a denture.And there are almost 5mm height of bone under the rugae area and along with mid-palatal line.

I. Design ConceptCharacteristics & Advantages

Characteristics & Advantages » Ⅰ. Design Concept

Page 19: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

– 243242 Palatal Denture StabilizerTM

Fixture ProductI. Size

Ø3.5

2.0

Ø2.0 5

PF3525

3.0 PF3535

4.0 PF3545

5.0 PF3555

CuffHeight

CoreDiameter

Length(mm) Ref. CDiameter

Ø3.5• Cuff:2/3/4/5mm• Fixture Length : 5mm

Ø3.0

C.H

5

Ø3.0

2.0

Ø2.0 5

PF3025

3.0 PF3035

4.0 PF3045

5.0 PF3055

CuffHeight

CoreDiameter

Length(mm) Ref. CDiameterØ3.0

• Cuff:2/3/4/5mm• Fixture Length : 5mm

Ø3.0

C.H

5

D

Fixture Product » Ⅰ. Size

Page 20: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

– 245244

Retentive Cap set

Lab Analog

Impression Coping

Abutment & Prosthetic OptionsI. Overdenture Level Prosthesis 1. Meg-Rhein Components

Abutment & Prosthetic Options » I. Overdenture Level Prosthesis

Page 21: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

– 245244 Palatal Denture StabilizerTM

Meg-Rhein Overdenture System- 1 Plastic Carrier- 1 Stainless Steel Housing- 1 Protective Disk- 5 Retentive Caps (Black-Lab, Yellow-0.6kg, Pink-1.2kg, White-1.8kg, Violet-2.7kg)

• Perfect compatibility with the Rhein83 from Italy.

Advantages

*With a proven ltalian techology, they are smaller and more convenient

then other products.

Product K & L

Product P

Meg-Rhein

4.4mm

2.1mm

2.25mm

2.3mm

5.5mm

5.2mm

30º

Violet(2.7kg)

White(1.8kg)

Pink(1.2kg)

Yellow(0.6kg)

1. Small & Easy-to-Use Housing System

2. Tilting Angle & Various Retentive Caps of the Meg-Rhein

3. Low Reduction Rate & Uniform Variance of Retentive Force

100

80

60

40

20

0Meg-Rhein Product K

Before After (1,000cycles)

Product L Product P

Ret

entiv

e fo

rce

(kg)

3

2

1

01,000 Cycles

R2=0.85

27%

7349%

51

38%

62

37%

63

R2(Coefficient of determination) becomes more reliable when it is close to “1”.

▸▸ Overdenture System

➲ Meg-Rhein Overdenture System

Stainless Steel Housing & Black Cap

Plastic carrier

Yellow Cap & Pink Cap

White Cap & Violet Cap

Protective Disk

8.8

MP

Ref.C

Abutment & Prosthetic Options » I. Overdenture Level Prosthesis

Page 22: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

– 247246

5 Stainless Steel Housing• 5ea/pack

MHP

Ref.C

➲ Components for Meg-Rhein Abutment

RCVP

Ref.C 5 Retentive Caps (Violet)• Violetcap(2.7kg)-Forrefill(5ea/pack).• Can be used for more retentive force following

white cap(1.8kg).

RCPP

Ref.C 5 Retentive Caps (Pink)• Pinkcap(1.2kg)-Forrefill(5ea/pack).

RCYP

Ref.C 5 Retentive Caps (Yellow)• Yellowcap(0.6kg)-Forrefill(5ea/pack).

RCBP

Ref.C 5 Retentive Caps (Black)• For laboratory

RCWP

Ref.C 5 Retentive Caps (White)• Whitecap(1.8kg)-Forrefill(5ea/pack).• Can be used for more retentive force following pink

cap(1.2kg).

Abutment & Prosthetic Options » I. Overdenture Level Prosthesis

Page 23: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

– 247246 Palatal Denture StabilizerTM

Stainless Impression Coping (Pick-Up)• 2ea/pack.• Italy - Rhein 83 products.• For accurate (pick-up type) impression.• Metal with groove design to prevent from swaying.

044CAIN

Ref.C 5.5

085IAC

Ref.C

83

40

Retentive Cap Insertion Tool• Retentive Cap insertion tool.

091EC

Ref.C

90

Retentive Cap Removal Tool• Retentive Cap removal tool.

PLA

Ref.C Lab Analog

Abutment & Prosthetic Options » I. Overdenture Level Prosthesis

Page 24: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

– 249248

DRILL H.C. R.C.

Surgical Kit

Cortical Drill

T-Ruler

RatchetConnector

Tip Driver

Cortical Drill Tip

Handle Tip

HandpieceConnector Option

Retentive Cap Removal Tool

Retentive Cap Insertion Tool

Surgical Kit

Page 25: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

– 249248 Palatal Denture StabilizerTM

➲ Surgical Kit Components (Continued)

TD

Tip Driver

Cortical Drill Tip• Manual drill for cortical bone drilling Ø1.4 80 PCDT

Diameter Length (mm) Ref.C

Handle Tip• Manual type

1.2780 PHTL

100 PHTLEL

Square Length (mm) Ref.C

Ref. C

Surgical Kit

Page 26: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

– 251250

Handpiece Connector• Handpiece type• Recommend torque : Less that 50Ncm 1.27

25 PHCS

30 PHCL

Square Length (mm) Ref.C

L

Ratchet Connector• Ratchet Wrench type• Recommend torque : Less that 50Ncm 1.27

20 PRCS

25 PRCL

Square Length (mm) Ref.C

L

Cortical Drill• Recommended drilling speed : 300~800 RPM

D

5

L

Ø1.428 PCDS

33 PCDL

Diameter Length (mm) Ref.C

➲ Surgical Kit Components

Surgical Kit

Page 27: MiNi - Välkommen till Implant Solutions i Göteborg, din ... · MiNi Overdenture Fixture ... • For the design concept and rationale of the Fuse Abutment, please refer to Page.084.

– 251250 Palatal Denture StabilizerTM

T-RulerPTR

Ref.C

83

40

Retentive Cap Insertion Tool• Retentive Cap insertion tool.

085IAC

Ref.C

091EC

Ref.C

90

Retentive Cap Removal Tool• Retentive Cap removal tool.

Surgical Kit