1 Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com August 22, 2011 Gene Pettingill State of Delaware Department of Natural Resources and Environmental Control [email protected]RE: Comments, Stakeholder Review Draft 082710B GMP, OTC Model Rule for Solvent Degreasing 2011 Dear Mr. Pettingill, Kyzen Corporation is a supplier of precision cleaning agents to Electronic Hardware OEMs (Original Equipment Manufacturers), EMS (Electronic Manufacturing Services), and Advanced Packaging (Microprocessors, Integrated Circuits, and Memory Devices) companies as well as a broad array of Industrial Equipment Manufacturers (motor parts, housings, etc.). Kyzen recently learned of the OTC Model Rule and ask that your department consider this late response. Table of Contents 1. Executive Summary 2. Electronic Assemblies 3. Solubility Methodologies 4. Contamination and its Effects on Electronic Assemblies 5. Five Cleaning Forces 6. Comments to the OTC Model Rule 7. Aqueous Cleaning Processes 8. Exhaust Engineering Controls 9. Conclusions 10. References 11. Mike Bixenman Qualifications
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
August 22, 2011 Gene Pettingill State of Delaware Department of Natural Resources and Environmental Control [email protected] RE: Comments, Stakeholder Review Draft 082710B GMP, OTC Model Rule for Solvent Degreasing 2011 Dear Mr. Pettingill, Kyzen Corporation is a supplier of precision cleaning agents to Electronic Hardware OEMs
(Original Equipment Manufacturers), EMS (Electronic Manufacturing Services), and
Advanced Packaging (Microprocessors, Integrated Circuits, and Memory Devices)
companies as well as a broad array of Industrial Equipment Manufacturers (motor parts,
housings, etc.). Kyzen recently learned of the OTC Model Rule and ask that your department
consider this late response.
Table of Contents
1. Executive Summary
2. Electronic Assemblies
3. Solubility Methodologies
4. Contamination and its Effects on Electronic Assemblies
5. Five Cleaning Forces
6. Comments to the OTC Model Rule
7. Aqueous Cleaning Processes
8. Exhaust Engineering Controls
9. Conclusions
10. References
11. Mike Bixenman Qualifications
2
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
1.0 Executive Summary
Cleaning is an important step in assuring reliability of the electronics device for its intended
function. The OTC Model Rule for Solvent Degreasing 2011 section on cold cleaners with a
recommended limit of permissible VOC to 25 grams/liter is a concern. As devices
miniaturize in size, the flux composition in the solder alloy relies on higher molecular weight
resins, activators, and functional additives to facilitate a strong metallurgical bond. The
cleaning agents needed to remove flux residues from circuit assemblies require a
combination of dispersive, polar, and hydrogen bonding forces. A VOC limit of 25
grams/liter is inoperable for a vast majority of the solder material residues used when
assembling complex circuitry.
Over the past 10 years, there have been significant advances in aqueous cleaning agents and
cleaning equipment for cleaning electronic assemblies. Formulations with less than 25 grams
/ liter VOC have been designed, but data from numerous studies indicate that these cleaning
products do not match up well with many of the common flux types used to assemble printed
circuit boards. Kyzen has worked with numerous electronic assembly companies in the State
of California subject to the 25 grams/liter VOC rule. For high value production, many of
these companies have located their assembly operations outside California, with this rule
being one of those considerations for leaving California.
Electronic manufacturers are faced with the dilemma of determining the level of cleanliness
needed to produce reliable hardware. The question of “how clean is clean” is more
challenging as conductors and circuit traces are increasingly narrower.9 Residues on a printed
board, component, or printed board assembly increase the risk of premature failure or
improper function, complicate the manufacturing process, and represent a decrease in quality.
3
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
Kyzen has compiled a library of solubility data on many of the soils used to build electronic
assemblies. The flux component is an important enabler to creating acceptable solder
connections. The soldering materials required to assemble complex circuitry must be stable
at temperatures exceeding 240°C. At these elevated temperatures, flux compositions must be
thermally stable. Water soluble flux compositions do not possess the thermal stability
required to solder many lead-free circuit assemblies. Cleaning products formulated at 25
grams / liter do not remove many of these soils. Low volatile oxygenated solvents formulated
into aqueous engineered materials have been successfully combined with water for cleaning
most of the residue types present when assembling printed circuit boards.
To achieve the desired effect, the cleaning formulation requires a combination of dispersive
(solvency), polarity, and hydrogen bonding forces. Supplementing the solvency with
inorganic builders, bases, and / or acids creates significant material compatibility, reliability
and subpar cleaning concerns. For building electronic hardware, cleaning agents that allow
the use of VOC materials up to 200 grams / liter provides formulation flexibility for meeting
electronic assembly cleaning needs.
2.0 Electronic Assemblies
Electronic devices innovations have changed the way people communicate, interact and
work. As the current trends toward miniaturization take hold, proper cleanliness levels
become more difficult to achieve. High density circuit designs by definition allow only
smaller spacing between conductors yielding a larger electric field, which in conjunction
with insufficient cleaning can lead to electrochemical failures.
Cleaning is an important step in assuring reliability of the electronics device for its intended
function. As devices miniaturize in size, the flux composition in the solder alloy relies on
higher molecular weight resins, activators, and functional additives to facilitate a strong
metallurgical bond. The cleaning agents needed to remove flux residues from circuit
assemblies require a combination of dispersive, polar, and hydrogen bonding forces. This
4
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
response to the OTC seeks to help the commission understand the need for cleaning and
limits needed to accomplish the cleaning task.
3.0 Solubility Methodologies
The process cleaning rate theorem holds that the rate at which a solvent or cleaning agent
dissolves a residue (static rate) plus mechanical energy (dynamic rate) equals the process
cleaning rate.1 To determine the static cleaning rate (rate at which the cleaning agent
dissolves the residue in the absence of mechanical energy), Kyzen uses two static cleaning
tests. The first test develops a composite solubility parameter for each flux residue in the test
matrix. The solubility parameter provides insight into the material sets that dissolve the
residue and the chemical characteristics of the residue. The second test exposes each flux
residue to different cleaning agents in an effort to match up the right cleaning agent to the
soil matrix. This testing provides insight into the technology base options for cleaning the
residue set.
The test methodology defines a sphere (Figure 1) from the properties of specific solvents and
engineered cleaning agents that were exposed to the soil. The test provides a set of
solvent/cleaning agent properties that match up (dissolve) the soils in the test matrix. The
objective is to develop a sphere whose circumference is defined by the solvents/cleaning
agents that dissolve the soil (inside solvents represented by blue circles). Solvents/cleaning
agent’s inside the sphere are considered relevant solvents, which have properties that require
the least amount of mechanical work to dissolve the soil.
Red squares represent solvents/cleaning agents that did not dissolve the soil efficiently.
These solvents/cleaning agents are considered outside solvents. The properties of the inside
and outside solvents/cleaning agents provide insight into the properties of the soil and forces
needed within a designed cleaning agent for dissolving the soil.
5
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
Figure 1: Solubility Sphere
Each solvent tested has a dispersive, polarity, and hydrogen bonding value (Figure 2). These
values can be used to determine the optimal properties from which a cleaning agent will
rapidly dissolve the soil. The values for each solvent and their distance from the center of the
sphere can be used to calculate a composite solubility parameter for the soil.
Inside Solvents
Outside Solvents
6
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
Figure 2: Solvent Families Tested2
Oxygenated solvents in combination with functional additives have been formulated with
water and are highly effective at removing rosin, no-clean, and water soluble flux residues.
The cleaning agents are effective at concentration ranges of 3-20% in water, depending on
the flux residue composition. At these concentration levels, the VOC content ranges from 20-
180 grams per liter. Figure 3 shows a second Teas chart showing the solvents position.
Higher dispersive forces are in the right hand corner, higher polarity forces increase in height
on the right side of the triangle, and higher hydrogen bonding forces are closer to the base on
the left side of the triangle. For effective cleaning, these forces need to align with these same
forces in the residue. For example, a no-clean flux residue (most common in industry)
contains a combination of materials encased in a resin. To clean this residue, the cleaning
agent requires a combination of dispersive forces to dissolve the resin, polarity forces to
dissolve polar materials through positive and negative attractions, and hydrogen bonding
forces to solubilize the residue in an aqueous medium. By taking away any one of these
forces, the cleaning medium will not be optimal.
7
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
Figure 3: Solvent Positions within the Solubility Sphere3
Other factors such as temperature, concentration of aqueous cleaning agents, and time can be
designed into the test matrix. These other factors provide information for determining the
process window. The test methodology provides two critical insights:
1.) The chemical properties needed to dissolve the soil
2.) The process conditions in the form of time, temperature, and concentration
needed to clean the soil in the selected cleaning equipment.
A limitation of static testing methodologies is that the method does not take into account
dynamic energy and its effects on cleaning the part. Dynamic energy delivers the cleaning
agent to the soil and with the right forces improves cleaning performance, even with
boundary cleaning agents. Stronger forces applied directly to the source have been found to
improve soil removal. In theory, cleaning agents that are a closer match to the soil
complement the source of energy and open the process window.
Higher Dispersive Forces
8
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
Solubility testing methodology can be used to develop and correlate the solubility properties
of known specific solvent / cleaning agent families to determine the cleaning properties for
any soil. This method was used to determine the cleaning properties needed to clean flux
residues from the following soldering materials.
1. Lead-Free Water Soluble #1
2. Lead-Free Water Soluble #2
3. Tin-Lead No-Clean #1
4. Tin-Lead No-Clean #2
5. Lead-Free No-Clean #1
6. Lead-Free No=Clean #2
The six solder pastes in this study were reflowed onto test vehicles and exposed to a series of
solvents with known solubility parameters. The test coupons were graded based on each
solvent’s ability to dissolve the residue. The test values were used to calculate a composite
solubility parameter for each solder paste tested.
Each test solvent has a dispersive value (solvency power for dissolving a soil), polarity value
(positive or negative charge attractions), and hydrogen bonding value (sharing electrons with
electro-negative atoms such as oxygen, nitrogen, and fluorine). Each of the solder paste flux
residues in the test matrix were immersed into the test solvents. The test coupons were
graded using values between one and six based on the solvent / cleaning agent’s affinity to
dissolve the soil. A “1” represents an inside solvent/cleaning agent that matches up well with
the soil and a score of “6” has no effect (Figure 4/Table 1).
9
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
Figure 4: Grading Scale 1-6
Score Description 1 Easily cleaned – No residue 2 Light residue 3 Moderate residue - Boundary cleaning agent 4 Reluctant to clean 5 Low level cleaning 6 No interaction with cleaning agent
Table 1: Grading Description
The combined dispersive, polarity, and hydrogen bonding values for each soil tested were
used to calculate a composite set of solubility values for each soil (Figure 5). These values
provide insight into the chemical properties needed to dissolve the soil matrix. Soils with
high dispersive values tend to be more covalent in structure. Soils with high polarity values
possess reactive sites with solvents that have a partial positive or negative charge in the
valence electron shell, which increases dissolution from the forces of attraction. Soils with
high hydrogen bonding values tend to have oxygen or nitrogen within the molecular structure
that readily share their electrons with hydrogen, which improves the soils dissolution in water
based cleaning agents.
10
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
0
5
10
15
20
25
Dispersive Value
Polarity Value
Hydrogen Bonding Value
Figure 5: Solubility Values
Water Soluble Lead Free Solder Paste Flux Residues
The solubility parameter for water soluble lead-free solder paste #1 had a moderate
dispersive value, low polarity value and high hydrogen bonding value. The solubility
parameter for water soluble lead-free solder paste #2 had a moderate dispersive, polarity and
hydrogen bonding values. Figure 6 provides a view of the solvent families that were effective
at dissolving the flux residues from these two water soluble lead-free solder pastes.
11
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
Solve
nt Fa
mily 9
Solve
nt Fa
mily 8
Solve
nt Fa
mily 7
Solve
nt Fa
mily 6
Solve
nt Fa
mily 5
Solve
nt Fa
mily 4
Solve
nt Fa
mily 3
Solve
nt Fa
mily 2
Solve
nt Fa
mily 14
Solve
nt Fa
mily 13
Solve
nt Fa
mily 12
Solve
nt Fa
mily 11
Solve
nt Fa
mily 10
Solve
nt Fa
mily 1
5
4
3
2
1
Solvent Family
Mea
n
Water Soluble LF 1Water Soluble LF 2
Soil
Interaction Plot for Water Soluble Lead-Free Solder Pastes Data Means
Figure 6: Solvent Family Interaction on Water Soluble Soils
Water soluble flux residue #2 was easily dissolved in many of the solvent families while
Water soluble flux residue #1 was less dispersive in a number of the solvent families. The
data indicates that water soluble paste #1 will be more challenging to clean.
Tin-Lead No-Clean Solder Paste Flux Residues
The solubility parameter for tin-lead no clean solder paste #1 had a high dispersive value,
low polarity value and moderate hydrogen bonding value. The solubility parameter for tin-
lead no clean solder paste #2 had a moderate dispersive, low polarity and low hydrogen
bonding values. Figure 7 provides a view of the solvent families that were effective at
dissolving the flux residues from these two tin-lead no clean solder pastes.
12
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
Solve
nt Fa
mily 9
Solve
nt Fa
mily 8
Solve
nt Fa
mily 7
Solve
nt Fa
mily 6
Solve
nt Fa
mily 5
Solve
nt Fa
mily 4
Solve
nt Fa
mily 3
Solve
nt Fa
mily 2
Solve
nt Fa
mily 14
Solve
nt Fa
mily 13
Solve
nt Fa
mily 12
Solve
nt Fa
mily 11
Solve
nt Fa
mi ly 10
Solve
nt Fa
mily 1
6
5
4
3
2
1
Solvent Family
Mea
n
Tin-Lead No Clean 1Tin-Lead No Clean 2
Soil
Interaction Plot for Tin-Lead No-Clean Solder PastesData Means
Figure 7: Solvent Family Interaction on Tin-Lead NC Soils
The solubility properties of the two tin-lead no-clean soils were similar. The data indicates
that the cleaning performance for these two soils will be similar.
Lead-Free No-Clean Solder Paste Flux Residues
The solubility parameter for lead-free no clean solder paste #1 had a high dispersive value,
low polarity value and moderate hydrogen bonding value. The solubility parameter for lead-
free no clean solder paste #2 had a high dispersive, moderate polarity and moderate hydrogen
bonding values. Figure 8 provides a view of the solvent families that were effective at
dissolving the flux residues from these two lead-free no clean solder pastes.
13
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
Solve
nt Fa
mily 9
Solve
nt Fa
mily 8
Solve
nt Fa
mily 7
Solve
nt Fa
mily 6
Solve
nt Fa
mily 5
Solve
nt Fa
mily 4
Solve
nt Fa
mily 3
Solve
nt Fa
mily 2
Solve
nt Fa
mily 14
Solve
nt Fa
mily 13
Solve
nt Fa
mily 12
Solve
nt Fa
mily 11
Solve
nt Fa
mily 10
Solve
nt Fa
mily 1
6
5
4
3
2
1
Solvent Family
Mea
n
Lead-Free No Clean 2Lead Free No Clean 1
Soil
Interaction Plot for Lead Free No-Clean Solder Pastes Data Means
Figure 8: Solvent Family Interaction on Lead-Free NC Soils
The solubility properties for the two lead-free no clean solder pastes were also very similar.
A stark contrast to the tin-lead and water soluble no clean solder pastes is that the lead-free
no clean solder pastes were much harder to clean.
Solubility testing gives the formulator insight into the make-up of the soil and the forces
needed to clean the soil. This data provides insight into the dispersive, polarity, and hydrogen
bonding forces needed within the cleaning agent to remove the soil. Other techniques such as
FTIR, GCMS, and HPLC can be used to characterize the organic makeup of the soil (Figure
9).
14
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
Figure 9: Utilize FTIR, GC-MS, and HPLV, to Characterize Soil Differences10
Matching the Cleaning Agent to the Soil
The first set of test values found the interaction of different solvent families on the solder
paste flux residues in the test matrix. This test provides an overview of aqueous cleaning
solvents that rapidly dissolve the soil. Process conditions in the form of VOC content, time,
temperature and concentration were tested to determine the optimal condition for removing
the soil. The operating premise is that “cleaning agents with like properties to the soil will
matchup and dissolve the soil.” The data findings compare and contrast the static cleaning
rate for four aqueous cleaning agents with different levels of VOC.
The static cleaning rate was developed on four aqueous cleaning agents. Table 2 lists the
cleaning agent properties. The aqueous products are formulated as concentrated engineered
compositions designed to be diluted with water. Three concentration levels were tested with
three solution temperatures ran at each concentration. The test vehicles were graded using the
scale in Figure 3 and Table 1.
15
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
Cleaning Agent Conc. Levels
Tested
Temp.
Levels
Tested
VOC
grams/liter
pH
High Solvency/ Low Reactivity
(HSLR)
1.) 10%
2.) 15%
3.) 20%
1.) 20°C
2.) 40°C
3.) 60°C
1.) 94
2.) 141
3.) 188
9.8
Medium Solvency/Medium
Reactivity (MSMR)
4.) 10%
5.) 15%
6.) 20%
4.) 20°C
5.) 40°C
6.) 60°C
4.) 60.9
5.) 91.35
6.) 121.8
10.6
Medium Solvency/High
Reactivity (MSHR)
7.) 10%
8.) 15%
9.) 20%
7.) 20°C
8.) 40°C
9.) 60°C
7.) 88.9
8.) 133.35
9.) 177.8
11.5
Low Solvency/ High Reactivity
(LSHR)
10.) 10%
11.) 15%
12.) 20%
10.) 20°C
11.) 40°C
12.) 60°C
10.) 19.5
11.) 29.25
12). 39
11.0
Table 2: Aqueous Cleaning Factors / Levels Tested
The main effects plot for the two water soluble lead free solder pastes (Figure 10) provides
meaningful process information. Pay attention to the grading scale as described in Table 1.
All four cleaning agents are effective at cleaning the water soluble soils including the Low
Solvency / High Reactivity cleaning agent that would meet the proposed limit of 25 grams
per liter. This is not unexpected since these residues are designed to be cleaned with water
only. The question one may ask is why not use water soluble solder pastes on all assembly
types. The answer is that water soluble flux residues are highly active, and if left trapped
under tight components, dendritic electrochemical migration grows rapidly. The second
concern is that water soluble fluxes cannot withstand the added heat need when soldering
lead-free alloys on highly dense components circuit designs. Assemblers building high
reliability hardware cannot risk highly active fluxes when failure cannot be tolerated.
16
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
MSMR
MSHR
LSHR
HSLR
6
4
2
201510
604020
6
4
2
188.
00
177.
80
141.
00
133.
35
121.
8094
.00
91.3
588
.90
60.9
039
.00
29.2
519
.50
Cleaning Agent
Mea
n
Conc.
Temp VOC
Main Effects Plot for Water Soluble Flux Data Means
Figure 10: Main Effects Plot for Lead-Free Water Soluble Fluxes
The main effects plot for the tin-lead no clean solder pastes (Figure 11) also provides
meaningful process information. Pay attention to the grading scale as described in Table 1.
The High Solvency / Low Reactivity and Medium Solvency / High Reactivity provided the
best static cleaning rate for the two soils evaluated. Cleaning performance improved as the
cleaning agent concentration and temperature increased. The data indicates that VOC content
in the range of 130 -170 grams per liter provided the best static cleaning rate.
17
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
MSMR
MSHR
LSHR
HSLR
6
4
2
201510
604020
6
4
2
188.
00
177.
80
141.
00
133.
35
121.
8094
.00
91.3
588
.90
60.9
039
.00
29.2
519
.50
Cleaning Agent
Mea
n
Conc.
Temp VOC
Main Effects Plot for Lead-Free Tin-Lead Flux Data Means
Figure 11: Main Effects Plot for Tin-Lead No-Clean Flux
The main effects plot for the lead-free no clean solder pastes (Figure 12) also provides
meaningful process information. Pay attention to the grading scale as described in Table 1.
The High Solvency / Low Reactivity cleaning agent provided the best static cleaning rate for
the two soils evaluated. Cleaning performance improved as the cleaning agent concentration
and temperature increased. The data indicates that VOC content in the range of 140 -188
grams per liter provided the best static cleaning rate.
18
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
MSMR
MSHR
LSHR
HSLR
4.5
4.0
3.5
3.0
2.5
201510
604020
4.5
4.0
3.5
3.0
2.5
188.
00
177.
80
141.
00
133.
35
121.
8094
.00
91.3
588
.90
60.9
039
.00
29.2
519
.50
Cleaning Agent
Mea
n
Conc.
Temp VOC
Main Effects Plot for Lead-Free No-CleanData Means
Figure 12: Main Effect Plot for Lead-Free No-Clean Flux
Solubility testing provides an accurate indicator of soil properties and the forces needed to
clean those soils. Documenting these methodologies may be helpful to the commission in
your assessment of what is needed for cleaning high valued circuit assemblies.
4.0 Contamination and its Effects on Electronic Assemblies
Increased electrical device functionality results from closer spacing between electrical solder
connections (cathode and anode) and more functions in a smaller area. Device
miniaturization increases the electric field attraction between conductors. Process and service
related contaminants accelerate the potential for device failures. Corrosion problems decrease
product and reduce functionality.
19
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
Ionic and non-ionic residues can occur from incoming components, soldering, and handling.
Ion migration leads to current leakage, galvanic coupling, and formation of electrochemical
cells.6 Cleaning is commonly considered based on the end use environment – Military,
Defense, Aerospace, Medical, Automotive, Information Technology, and Industrial etc. The
design / service life of the product (i.e. 90 days, 3 years, 20 years, 50 year, Life-time) must be
considered. The consequence of failure is also a factor (example: cell phone vs. pace maker)
when determining the value of cleaning.
No-clean soldering materials were introduced as a replacement for ozone depleting cleaning
agents in the early 1990’s. The hope was that cleaning could be eliminated as a part of the
assembly process. No-clean soldering technology is driven by cost pressures and difficulty of
6. IPC 5702. (2007, April). Guidelines for OEMs in Determining Acceptible Cleanliness
Levels on Unpopulated Boards. IPC, Bannockburn, IL.
7. Pippen, D.L. A Primer on Hand Soldering Electrical Connections. New Mexico State University.
8. Tarr, M. (n.d.) Wave Soldering. Creative Commons Attribution – Non Commercial – ShareAlike 2.0.
9. IPC (2011). IPC-CH-65B Guidelines for Cleaning of Printed Boards and Assemblies. IPC Association for Connecting Electronic Industries. Bannockburn, IL.
28
Mike Bixenman, D.B.A. Chief Technology Officer Kyzen Corporation 430 Harding Industrial Drive Nashville, TN 37211 615-983-4530 Direct 615-584-9089 Cell mikeb@kyzen,.com
10. Bixenman, M., Northrup, M., Buchan A., Russeau, J. & Jensen, T. (2011). Cleaning in an HDI World. IPC Midwest. Schaumberg, IL.
11.0 Mike Bixenman Qualifications
Mike is one of the joint founders and CTO of Kyzen Corporation. He is an active researcher
and innovator in the precision cleaning field. Mike chaired the IPC-CH-65B Guidelines for
Cleaning Printed Circuit Assemblies released in July 2011 and IPC-7526 Stencil Cleaning
Handbook. He has published over 100 research articles on the topic of precision cleaning.
Mike holds four earned degrees, including a Doctorate of Business Administration from the