Top Banner
40

Migrating from current loop to PROFIBUS PA - Dale Fittes and Dave Tomlin of Hitex

Jul 12, 2015

Download

Engineering

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 2: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 3: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 4: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 5: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 6: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 7: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 8: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 9: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex

One pair of wires for each device

Page 10: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 11: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 12: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 13: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 14: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex

Group Equipment Category

Locations Corresponds

to Comments

Gases Dusts

I M1 Mines

n/a Capable of functioning safely in the presence of an explosive atmosphere

I M2 Mines

n/a Must be de-energised when an explosive atmosphere is present

II 1G 1D Other

Zone 0 Protection assured in the event of two independent failures

II 2G 2D Other

Zone 1 Protection assured in the event of foreseeable failures

II 3G 3D Other

Zone 2 Protection assured during normal operation

Page 15: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex

Source : Wikipedia

Page 16: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 17: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex

Isolation Barrier

Page 18: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 19: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex

All this wiring could be replaced by a Single Twisted-Pair

Fieldbus-based

Page 20: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 21: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 22: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 23: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 24: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 25: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 26: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex

PROFINET

Page 27: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 28: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 29: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 30: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 31: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 32: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 33: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 34: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex

*

* Above 31.25kb/s

Page 35: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 36: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 37: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 38: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex
Page 40: Migrating from current loop to PROFIBUS PA  - Dale Fittes and Dave Tomlin of Hitex