This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Midea has been a world leader in Air Conditioners since its establishment in 1985. Midea has been exporting Air Conditioners for the last 16 years and has firmly established its footprint worldwide and developed strong partnerships with multinationals. Midea’s vertically integrated supply chain enables it to achieve maximum efficiency in production and product development, giving it a competitive edge over other brands.
With over 1000 engineers working round the clock and over 300 new products being developed and 100 new patents filed, Midea is dedicated to continuous improve product quality and excel customer satisfaction. New products account for 30% of total sales volume and 35% of gross profit.
Additionally, Midea provides comprehensive technical training and online customer service to help cater to its clientele worldwide.
2 1
Energy LabelingThe label aims at communicating information about the relative efficiency performance of different appliances to consumers, retailers and manufacturers mainly through the use of a categorical efficiency scale (from A to G), thus facilitating the comparison of efficiency between many products by consumers.
The energy label is particularly effective in giving the consumer correct and well-balanced information about the appliance’s consumption/performance ratio in an easy to read and understandable format. Indirectly, it spurs the manufacturer to update the product to bring it as far as possible into line with the consumer’s motivated choices.
“A” is the most efficient, “G” the least. The more energy efficient an appliance is, the more money you can save, and the more you help the environment.
EER: Energy efficiency class in cooling modeCOP: Energy efficiency class in heating mode
A EER > 3.20
C 3.00 ≥ EER > 2.80
B 3.20 ≥ EER > 3.00
E 2.60 ≥ EER > 2.40
D 2.80 ≥ EER > 2.60
G 2.20 ≥ EER
F 2.40 ≥ EER > 2.20
A COP > 3.60
C 3.40 ≥ COP > 3.20
B 3.60 ≥ COP > 3.40
E 2.80 ≥ COP > 2.60
D 3.20 ≥ COP > 2.80
G 2.40 ≥ COP
F 2.60 ≥ COP > 2.40
ManufacturerOutside unitInside unit
Energy
More ef f ic ient
Less ef f ic ientAnnual energy consumption,kWh in cooling mode
Cooling output kWEnergy e fficiency ratioFull load (the higher the better)
Type Cooling onlyCooling + Heating
Air cooledWater cooled
Heat output kW
Heating performanceA: higher G: lower
Noise(dB(A) re 1 pW)
Further information is containedin product brochures
Air-conditionerEnergy Label Directive 2002/31/EC
(Actual consumption will depend on how the apliance is usedand climate)
AB
CD
EFG
Air-conditioner
Creates a better lifeMidea has established an environmental management system (EMS) for our manufacturing sites based on the internationally recognized ISO 14001 standards. The intention is to further reduce the environmental impact of our activities. But achieving the ISO 14001 certification is not the end of Midea’s environmental efforts, we will take all necessary steps to maintain and do better for the environment in the future.
Comfortable lifeMidea products are compliant with the European Directive on the Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment, also known as the RoHS directive. Besides, Midea established systems for the collection and recycling of waste electrical and electronic products to comply with the WEEE Directive, the directive on Waste Electrical and Electronic Equipment.
Midea also recognizes the importance of energy saving. Therefore, we always promote the use of high efficiency refrigerants. In 2007, Midea acquired the R410A certification, which R410A is a leading ozone-friendly and highly energy saving refrigerant for residential air conditioning.
To create a better life, Midea constantly improve its products to ensure they achieve their highest performance under all situations.
ISO : 9001 ISO : 14001
4 3
Fresh A
ir
Fresco Tech
Polluted Air
Mideaʼs Fresco Tech brings you clean and refreshing air and fills your room with the soothing scent of nature.
Silver Ion
Silver Ion Filter Active Carbon Bio Filter Plasma Duct collector Vitamin C Filter Ionizer
Active C
arbon &
Dust Filter
Bio Filter
Plasma D
ust C
ollector
Vitamin C
Filter
IonizerThe Silver ion can kill bacteria or prevent their activity at very low density by destroying their inner-configuration and absorbing their elements in cells. Meanwhile, the Nano Silver attached on the filter release the Silver ion constantly to eliminate bacteria effectively and continuously.
Bio Filter consists of a specialized biological enzyme and Eco filter. The Eco filter catches very small airborne dust particles and neurilities bacteria, fungi and microbes.Biological enzyme eliminates bacteria by dissolving their cell wall thus eliminating the problem of re-pollution seen in traditional air conditioners.
The Plasma Dust Collector can generate an ionization zone. The air is converted to plasma as it passes the high voltage ion generator. 95% of the dust, smoke, and pollen particles are attracted to the electrostatic filter.
The Vitamin C filter fills the air with vitamin C, which softens the skin and reduces stress. The lifetime of the Vitamin C filter is approximately two years.
Anions can take care of your bodyAnions can stimulate the blood circulation system, improve lung function and effectively prevent respiratory passage illnesses (Such as asthma and pneumonia).
Anions Eliminate Dust and Smoke:When air passes through the ionizer brush, Anions are automatically generated by ionization (3400V high static field). The amount of anions can reach as high as 1,000,000/cm3. The anions deactivate the airborne chemical vapors and dust particles.
Dust electroded
Particles High electric voltage field
OdorGenerating plasma
Electronegative filter+5KV discharge Fresh Air
Polluted Air
4.Germ Dies
1.Germ & Enzyme 2.Cell Wall Dissolved
3. Cell Membrane Burst
CellEnzyme
Combine Wall
Sterilization mechanism of Bio Filter
Enzyme Dead Cell
Dust
Bacteria
DustMicrobes
Fungi
HCHODust
NH3 Smoke
Dust
VC Vitamin C Anions
Bacteria DustPollen
Active Carbon Electrostatic Fiber Filter is made of Active Carbon and Electrostatic Fiber Filter. Active Carbon Filter eliminates certain kinds of odors such as ammonia (NH3) and deactivates harmful chemical gas such as formaldehyde(HCHO).By forming positive positions on the filter surface, Electrostatic Fiber Filter traps small dust particles, smoke and pet fur to prevent allergic reactions.
Time(min)
Density of NH3
(mg/m3)NH3 Removal Ratio
(mg/m3)
0
30
60
120
3.17
0.51
0.28
0.22
*
83.91
91.17
93.06
NH3 Removal Ratio of Active Carbon Filter
76543210
Den
sity(m
g/m
3)
Time(min)0 10 20 30 40 50 60 70 80 90 100
Dust Removal Ratio of Electrostatic Fibre Filter
Con
cent
ratio
n of
Asc
orbi
c Ac
id(m
g/L)
0.70
0.65
0.60
0.55
0.50
0.45
0.30
1day 2days 3days 4days 5days 6days0.30
0.35
Performance of the emission in case of Continuous running
6hours 12hours 18hours 24hours0.0
1.00.90.80.70.60.50.40.30.20.1
Con
cent
ratio
n of
Asc
orbi
c Ac
id(m
g/L)
Progress of " Vitamin-C emission" every 6 hours
The photo is zoomed 3000 times.
Deodorization
Natural
Plasma
100
80
60
40
20
0
(%)
15 30 45 60(Min)
Dust Reduction
Natural100
80
60
40
20
0
(%)
10 20 30(Min)
Plasma
6 5
Golden Tech
Tele Remote Tech
Golden Bio EvaporatorIt can efficiently prevent bacteria from breeding and spreading. It helps create a health and comfortable environment.
Golden Anti-corrosive CondenserThe Golden hydrophilic condenser can improve the heating efficiency by accelerating the defrosting process. The unique anti-corrosive golden coating on the condenser can withstand the salty air, rain and other corrosive elements.
Midea’s Tele Remote Control Technology enables you to control your A/C at anytime and anywhere by telephone.
Automatic tone instruction makes it simple for the A/C setting such as the mode setting, temperature setting and fan speed setting.
Password setting ensures a safe operation.
50
150
200
300
%
100
250
350
400
Normal evaparatorGolden Bio evaparator
0
Changes of Germ Amount After 24h Test
6 12 18 24Time
Amou
nt o
f ger
m
Water Air SaltAluminum
Golden Coating Layer
Corrosion test results
Conventional condenser
Golden condenser
235
6890
#
7*
FeaturesAnti-Cold Air Function(Heat Pump Only)When the evaporator temperature is warm enough, the fan begins to operate, preventing any cold blasting.
Flexible Wiring ConnectionTerminal block makes the cable connecting between indoor and outdoor unit much more flexible.
Low Noise Air Flow SystemLarge Diameter Cross Flow FanWithout decreasing the flow volume, large diameter cross flow fan can greatly reduce the indoor unit’s noise level by lowering the fan speed.
Self-diagnosis and Auto-protection FunctionThis function can electronically detect the errors and display the diagnosis by a series of flashing LEDs on the indoor unit. Then the unit will automatically switch to protection mode.
Two-speed outdoor fan (applicable to models > 21000Btu/h)With 2-speed fan motor, the outdoor unit can operate powerfully at high speed or can be adjusted to quiet and low speed operation at night.
Auto-Restart FunctionWhen the power is off and then on, the unit automatically restores the previous function setting.
Oxygen Generating MechanismThe oxygen enrichment membrane in the outdoor unit can increase the oxygen density.
Independent DehumidificationThe unit will alternately operate in cooling mode or fan only mode, which assures strong dehumidification while not lowering room temperature.
Trapeziform Innergroove CopperCompared with the triangular innergroove copper, it allows more adequate refrigerant to go through, improving heat exchange efficiency and lowers power consumption.
Soft-starter KitIt can keep the starting current within the limit of 45A, which is suitable for some countries such as Australia, and the North European countries.
Valve Protection CoverIt protects the valves and prevents water from dripping.
Multi-Bend Heat ExchangerCompared with conventional models, Midea’s air-conditioners adopt multi-bend heat exchangers. It helps increase the heat-exchange surface so that it improves efficiency.
Sleep ModeThis function enables the unit to automatically increase (cooling) or decrease (heating) 1ºC per hour for the first two hours, then hold steady for the next 5 hours, after that the unit will stop operation. It can maintain the most comfortable temperature and save energy.
Follow MeWith this technology, a temperature sensor is built in the remote controller. When you stay close to the remote controller, the unit will automatically change the operation mode to supply more comfortable temperature just like the air conditioner is following you.
Anti-Rust CabinetMade from electrolytic zinc steel sheet and anti-rust coated components.
Temp. Compensation (Optional)The ceiling temperature is often higher than the floor temperature. This function can automatically eliminate the temperature difference between them.
Hydrophilic Aluminium FinIn the indoor unit, it improves the cooling efficiency by enabling the unrestricted flow of condensate between the heat exchange fins. In the outdoor unit, it improves the heating efficiency by accelerating the defrosting process.
Operating at Full Range VoltageAir Conditioner can run when the voltage is 250V or 160V.
Easy-cleaned PanelThe front panel may be easily removed for periodic cleaning.
Two-direction Air Vane TechnologyIn cooling mode, the air vane opens counterclockwise, which directs the air horizontally. It allows for rapid and evenly distributed temperature fall.In heating mode, the air vane opens clockwise, which directs the air towards the floor. It allows for rapid and evenly distributed temperature rise.
LCD DisplayControl panel adopt LCD display.
Self-cleaningThis function can be selected by remote controller. When the "CLEAN" button is pressed, the indoor unit will automatically clean the evaporator. This function can restrict the breeding of bacteria in the unit and keep the air fresh.
Free EER UpgradingMost products in the line-up may be freely upgraded to higher class (from "E" up to "A")
Low Ambient KitThe unit can operate in cooling mode at low ambient temperature conditions.
Fresh AirMidea air conditioner have a pump in the indoor unit, when press the "Fresh Air" button, the pump suck the fresh air from outside, and the indoor polluted air flow out of the room via the air pressure.
Turbo ModeThis function enables the unit to reach the preset temperature in the shortest time.
Intelligence EyeThe infrared ray caused by heat-radiancy is released by human boby every time.This ray can be apperceived by the sensor in the air-conditioner.The system can be started and turned off automatically by judging the heat-radiancy changing.
DSP High-speed ChipMidea inverter air-conditioner use the high speed chip by Texas Instruments, it makes response time of air-conditioner 20 times faster than ordinary MCU, and indoor temperature precisely controlled at +-0.5ºC.
PTC HeaterSafety PTC heating element.
Mutually Exchange systemAlternation operation mode can be realized via computer, extending the compressor.
8 7
Fan Speed AdjustmentHIGH / MED / LOW / AUTO
Air Flow Direction Setting
Temperature Setting(Time Adjustment)
Timer SettingTIMER / CANCEL
Clock Setting
LED Display
Sleep Mode
Turbo
Sliding Cover
On/Off Button
Mode SettingCOOL / HEAT / DRY / FAN / AUTO
Automatic Swing
Lock Pinhole Button
Reset Pinhole Button
Applicable to most of Mideaʼs models.Button design might be slightly different from the actual one depending on individual models.
J PlasmaP Soft-starter Kit
Special FunctionF IonizerL Low Ambient KitQ Quicker Connect
• Sliver Ion Filter• Bio Filter• Plasma Duct Collector• Vitamin C Filter• Ionizer• Anti-Rust Cabinet• Auto-Restart Function• DSP High-speed Chip• Easy-cleaned Panel• Follow Me• Free EER Upgrading• Golden Tech• Hydrophilic Aluminium Fin• Intelligence Eye• LCD Display
Features
Vertu
Family Resident ( Page 19 ~ Page 59 )
• Low Ambient Kit• Multi-Bend Heat Exchanger• Mutually Exchange System• Operating at Full Range Voltage• Oxygen Generating Mechanism• PTC Heater• Self-clean• Self-diagnosis and Auto-protection Function• Sleep Mode• Temp. Compensation• Trapeziform Innergroove Copper• Turbo Mode• Two-direction Air Vane Technology• Two-speed Outdoor Fan (applicable to
models > 21000Btu/h)
16 15
Midea Aircon FamilyFamily CombinationsThe indoor units of DC type can be matched freely when it is demanded if their capacities match. Midea indoor unit has strong flexibility. Any quantities of indoor unit, even coming from different family, can be droved in one outdoor unit.
With full experience in the air conditioning field, Midea constantly devotes itself into breakthrough of new technology research and development. All family products meet the residential customer demand by possessing of high energy efficiency ratio and it offers a better solution for energy saving and environment protection by using new refrigerant.
Midea releases the concept of Family Product by controlling the international standard production process and managing system. The family which meets each panel can be arranged to five types products: single on/off, DC Inverter, DC Inverter Multi, AC Inverter Multi and Multi on/off.
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor
Liquid SideGas Side
Btu/W.h, W/WW/W
m3/hA
4.55
62037/33/28
52
A AEnergy Rate
dB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
m2
kWHeating Btu/h
450(190-700)520(200-720)
550(210-740)220-240, 50, 1
580(220-800)800(300-1160)220-240, 50, 1
840(320-1260)Power Input Cooling Heating
WW
Electrical Parts
Capacity
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
MSP-07HRDN1-QD5 MSP-09HRDN1-QD5 MSP-12HRDN1-QD0
M2OB-18HRDN1 M3OA-27HRDN1 M4OA-27HRDN1
DC Inverter
DC Inverter
DC Inverter
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
PackingNet/Gross WeightOutdoor air flowOutdoor noise level
mm
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Types of Indoor Unit Combinations
One Unit Two Units79
12
7+77+97+12
9+99+1212+12
Three Units7+7+77+7+97+7+12
7+9+97+9+127+12+12
9+9+99+9+12
One Unit Two Units79
12
7+77+97+12
9+99+1212+12
17 Types 9 Types
Remarks: One outdoor unit can drive 4 free-matched indoor units at most.
One Unit Two Units79
12
7+77+97+12
9+99+1212+12
Three Units Four Units7+7+77+7+97+7+12
7+9+97+9+127+12+12
9+9+99+9+129+12+12
12+12+12 7+7+7+77+7+7+97+7+7+12 7+7+12+12
7+7+9+97+7+9+12
7+9+9+9
7+9+12+127+9+9+12
9+9+9+99+9+9+12
30 Types
22
Vertu Family220-240V~,50Hz
21
Castle Family_DC Inverter Multi
24 23
Vertu Family_DC Inverter Multi Vertu Family_DC Inverter
MSV1I-07HRDN1
MSV1I-18HRDN1
Features:
Standard Optional
MSV1I-09HRDN1
MSV1I-12HRDN1
MSV1-07/09/12HRDN1-QC2(A)
MSV1-24HRDN1-QC0F
MSV1-18HRDN1-QC2F
Features:
Standard Optional
Specification:
Model
Cooling Only Cooling & Heating
MOC-07HDN1-QC2 MSV1-07HRDN1-QC2(A)
MOC-09HDN1-QC2 MSV1-09HRDN1-QC2(A)
MOC-12HDN1-QC2 MSV1-12HRDN1-QC2(A)
MOF-18HDN1-QC2 MSV1-18HRDN1-QC2F
MOG-24HDN1-QC0 MSV1-24HRDN1-QC0F
Operating Current Cooling Heating
Outdoor
kW
V~,Hz,Ph
AA
Cooling
Voltage,Frequency,Phase
Btu/h
20'/40'/40'HQ
EERCOP
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor
PackingNet/Gross WeightOutdoor air flowOutdoor noise level
mm
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
DC Inverter DC Inverter
MSV1I-07HRDN1
5707000/8500
850x340x285795x270x165
37Ø6.35/Ø9.53
10.0/11.5
5709000/10000
850x340x285795x270x165
37Ø6.35/Ø9.53
10.0/11.5
MSV1I-09HRDN1
70012000/14000
905x355x285845x286x165
40Ø6.35/Ø12.7
10.5/12.0
MSV1I-12HRDN1
80018000/19000
1100x415x290995x292x194
42Ø6.35/Ø12.7
12.5/15.5
MSV1I-18HRDN1
Types of Indoor Unit Combinations Remarks: One outdoor unit can drive 4 free-matched indoor units at most.
PackingNet/Gross WeightOutdoor air flowOutdoor noise level
mm
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
WxHxDWxHxDIndoor/Outdoor
Indoor unitOutdoor unitGross Weight
Liquid SideGas Side
Btu/W.h, W/WW/W
m3/hEnergy Rate
dB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
m2
kWHeating Btu/h
70002.1
10.9,3.21-
45036/33/30
54
220-240, 50, 1
2.8-
10-14
120/258/292
700x535x235795x270x165
10/27
815x580x325850x285x335
12.5/30
Ø6.35(1/4")Ø9.53(3/8")
--
A
640-
70002.1
10.9,3.213.61
45036/33/30
54
220-240, 50, 1
2.82.9
10-14
120/258/292
700x535x235795x270x165
10/28.5
815x580x325850x285x335
12.5/30.5
Ø6.35(1/4")Ø9.53(3/8")
80002.3
A
640650
90002.6
11.0,3.22-
55038/35/32
54
220-240, 50, 1
3.6-
14-21
115/226/268
780x540x250795x270x165
10/30
910x575x335850x285x335
12.5/33
Ø6.35(1/4")Ø9.53(3/8")
--
A
820-
90002.6
11.0,3.223.61
55038/35/32
54
220-240, 50, 1
3.63.7
14-21
115/226/268
780x540x250795x270x165
10/31
910x575x335850x285x335
12.5/34
Ø6.35(1/4")Ø9.53(3/8")
103003.0
A
820840
120003.5
11.0,3.22-
65040/37/34
55
220-240, 50, 1
4.8-
18-26
108/220/258
780x540x250845x286x165
10.5/34
910x575x335905x350x285
13.5/37
Ø6.35(1/4")Ø12.7(1/2")
--
A
1090-
120003.5
11.0,3.223.63
65040/37/34
55
220-240, 50, 1
4.84.6
18-26
108/220/258
780x540x250845x286x165
10.5/34
910x575x335905x350x285
13.5/37
Ø6.35(1/4")Ø12.7(1/2")
130003.8
A
10901050
Power Input CoolingHeating
WW
Electrical Parts
Capacity
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
MSV1I-07HRDN1
5707000/8500
850x340x285795x270x165
37Ø6.35/Ø9.53
10.0/11.5
5709000/10000
850x340x285795x270x165
37Ø6.35/Ø9.53
10.0/11.5
MSV1I-09HRDN1
70012000/14000
905x355x285845x286x165
40Ø6.35/Ø12.7
10.5/12.0
MSV1I-12HRDN1
80018000/19000
1100x415x290995x292x194
42Ø6.35/Ø12.7
12.5/15.5
MSV1I-18HRDN1
One Unit Two Units79
12
7+77+97+12
18 7+18
9+99+129+18
12+1212+18
13 Types Types of Indoor Unit Combinations Remarks: One outdoor unit can drive 4 free-matched indoor units at most.
7+7+77+7+97+7+12
7+9+97+9+127+12+12
9+9+129+12+12
7+7+18 9+9+9
One Unit Two Units79
12
7+77+97+12
18 7+18
9+99+129+18
12+1212+18
23 TypesThree Units
7+7+77+7+97+7+12
7+9+97+9+127+9+18
7+12+189+9+99+9+129+9+18
9+12+129+12+1812+12+12
7+7+18 7+12+12
One Unit Two Units79
12
7+77+97+12
18 7+18
9+99+129+18
12+1212+18
40 TypesThree Units Four Units
7+7+7+77+7+7+97+7+7+12
7+7+9+97+7+9+127+9+9+9 7+7+12+12
7+9+12+12
9+9+9+99+9+9+12
7+7+7+18 7+9+9+12
28
Vertu Family_Multi
27
Vertu Family_Single
MSV1I-09HRN1
MSV1I-12HRN1
Features:
Standard Optional
Specification:
Model
Model
Specification: Cooling Only Cooling & Heating
Model
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Indoor Unit
Outdoor Unit
mmAir FlowDimension WxHxD
Capacity Cooling/Heatingm3/hBtu/h
kgdB(A)
Packing WxHxDNet/Gross WeightIndoor noise level (Hi/Mi/Lo) Liquid side/Gas side
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor
Liquid SideGas Side
Btu/W.h, W/WW/W
m3/hA
4.2
65038/34/28
52
A AEnergy Rate
dB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
m2
kWHeating Btu/h
510(190-700)620(230-820)
660(300-1100)220-240, 50, 1
690(310-1150)970(400-1480)220-240, 50, 1
950(390-1460)Power Input Cooling Heating
WW
Electrical Parts
Capacity
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
DC Inverter
DC Inverter
DC Inverter
DC Inverter
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
32 31
Alfa Family_DC Inverter Multi Alfa Family_DC Inverter
MSHI-07HRIN1
MSHI-18HRDN1
Features:
Standard Optional
MSHI-09HRIN1
MSHI-12HRIN1
Specification:
Model
Cooling Only Cooling & Heating
MOC-07HDN1-QC2 MSH-07HRDN1-QC2(A)
MOC-09HDN1-QC2 MSH-09HRDN1-QC2(A)
MOC-12HDN1-QC2 MSH-12HRDN1-QC2(A)
MOF-18HDN1-QC2 MSH-18HRDN1-QC2
MOG-24HDN1-QC0 MSH-24HRDN1-QC0
Operating Current Cooling Heating
Outdoor
kW
V~,Hz,Ph
AA
Cooling
Voltage,Frequency,Phase
Btu/h
20'/40'/40'HQ
EERCOP
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor
PackingNet/Gross WeightOutdoor air flowOutdoor noise level
mm
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
MSH-07/09/12HRDN1-QC2(A)
MSH-24HRDN1-QC0
MSH-18HRDN1-QC2
Features:
Standard Optional
DC InverterDC Inverter
MSHI-07HRIN1
5707000/8500
830x336x285750x250x205
40Ø6.35/Ø9.53
8.0/10.0
5709000/11000
830x336x285750x250x205
40Ø6.35/Ø9.53
8.5/10.0
MSHI-09HRIN1
67512000/14000
915x360x290815x280x215
41Ø6.35/Ø12.7
10.0/12.0
MSHI-12HRIN1
85018000/19000
1020x385x320920x292x224
43Ø6.35/Ø12.7
11.5/14.5
MSHI-18HRDN1
Types of Indoor Unit Combinations Remarks: One outdoor unit can drive 4 free-matched indoor units at most.
PackingNet/Gross WeightOutdoor air flowOutdoor noise level
mm
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
EERCOPDimension WxHxDPacking WxHxDNet/Gross WeightOutdoor air flowOutdoor noise level
W/WW/Wmmmmkg
m3/hdB(A)
Power Input Cooling/Heating W
Electrical Data
Capacity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
40 39
Corona Family_DC Inverter Multi Corona Family_DC Inverter
MSCI-07HRIN1
MSCI-18HRDN1
Features:
Standard Optional
MSCI-09HRIN1
MSCI-12HRIN1
MSC-07/09/12HRDN1-QC2(A)
MSC-24HRDN1-QC0
MSC-18HRDN1-QC2
Features:
Standard Optional
Specification:
Model
Cooling Only Cooling & Heating
MOC-07HDN1-QC2 MSC-07HRDN1-QC2(A)
MOC-09HDN1-QC2 MSC-09HRDN1-QC2(A)
MOC-12HDN1-QC2 MSC-12HRDN1-QC2(A)
MOF-18HDN1-QC2 MSC-18HRDN1-QC2
MOG-24HDN1-QC0 MSC-24HRDN1-QC0
Operating Current Cooling Heating
Outdoor
kW
V~,Hz,Ph
AA
Cooling
Voltage,Frequency,Phase
Btu/h
20'/40'/40'HQ
EERCOP
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor
PackingNet/Gross WeightOutdoor air flowOutdoor noise level
mm
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
DC InverterDC Inverter
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
80018000/19000
1015x368x295920x292x225
44Ø6.35/Ø12.7
11.5/15
MSCI-18HRDN1
Types of Indoor Unit Combinations Remarks: One outdoor unit can drive 4 free-matched indoor units at most.
PackingNet/Gross WeightOutdoor air flowOutdoor noise level
mm
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
WxHxDWxHxDIndoor/Outdoor
Indoor unitOutdoor unitGross Weight
Liquid SideGas Side
Btu/W.h, W/WW/W
m3/hEnergy Rate
dB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
m2
kWHeating Btu/h
70002.1
10.9,3.21-
45035/32/30
49
220-240, 50, 1
2.8-
10-14
126/272/298
700x535x235710x250x195
8/27
815x580x325800x340x270
9.5/30
Ø6.35(1/4")Ø9.53(3/8")
--
A
640-
70002.1
10.9,3.213.61
45035/32/30
49
220-240, 50, 1
2.83.0
10-14
126/272/298
700x535x235710x250x195
8/28.5
815x580x325800x340x270
9.5/30.5
Ø6.35(1/4")Ø9.53(3/8")
85002.5
A
640690
90002.6
11.0,3.22-
50037/34/31
50
220-240, 50, 1
3.8-
14-21
113/238/274
780x540x250710x250x195
8/30
910x575x335800x340x270
9.5/33
Ø6.35(1/4")Ø9.53(3/8")
--
A
820-
90002.6
11.0,3.223.62
50037/34/31
50
220-240, 50, 1
3.84.0
14-21
113/238/274
780x540x250710x250x195
8/31
910x575x335800x340x270
9.5/34
Ø6.35(1/4")Ø9.53(3/8")
110003.2
A
820890
120003.5
11.0,3.22-
58040/37/34
50
220-240, 50, 1
4.8-
18-26
94/199/232
780x540x250790x265x195
9/34
910x575x335875x375x285
11/37
Ø6.35(1/4")Ø12.7(1/2")
--
A
1090-
120003.5
11.0,3.223.63
58040/37/34
50
220-240, 50, 1
4.84.6
18-26
94/199/232
780x540x250790x265x195
9/38
910x575x335875x375x285
11/41
Ø6.35(1/4")Ø12.7(1/2")
130003.8
A
10901050
180005.3
10.5,3.073.42
85042/39/37
52
220-240, 50, 1
7.57.1
28-40
70/148/170
845x695x335920x292x225
13/52
965x755x3951015x368x295
15/56
Ø6.35(1/4")Ø12.7(1/2")
190005.6
B
17201630
180005.3
10.5,3.07-
85042/39/37
52
220-240, 50, 1
7.5-
28-40
70/148/170
845x695x335920x292x225
13/52
965x755x3951015x368x295
15/56
Ø6.35(1/4")Ø12.7(1/2")
--
B
1720-
Power Input CoolingHeating
WW
Electrical Parts
Capacity
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
One Unit Two Units79
12
7+77+97+12
18 7+18
9+99+129+18
12+1212+18
13 Types Types of Indoor Unit Combinations Remarks: One outdoor unit can drive 4 free-matched indoor units at most.
7+7+77+7+97+7+12
7+9+97+9+127+12+12
9+9+129+12+12
7+7+18 9+9+9
One Unit Two Units79
12
7+77+97+12
18 7+18
9+99+129+18
12+1212+18
23 TypesThree Units
7+7+77+7+97+7+12
7+9+97+9+127+9+18
7+12+189+9+99+9+129+9+18
9+12+129+12+1812+12+12
7+7+18 7+12+12
One Unit Two Units79
12
7+77+97+12
18 7+18
9+99+129+18
12+1212+18
40 TypesThree Units Four Units
7+7+7+77+7+7+97+7+7+12
7+7+9+97+7+9+127+9+9+9 7+7+12+12
7+9+12+12
9+9+9+99+9+9+12
7+7+7+18 7+9+9+12
80018000/19000
1015x368x295920x292x225
44Ø6.35/Ø12.7
11.5/15
MSCI-18HRDN1
MSC-18CRN1
MSC-21/24CRN1
MSC-09/12CRN1
MSC-28HRN1
MSC-21/24HRN1
MSC-09/12HRN1
MSC-18HRN1
MSC-28CRN1
Specification:
MSC-07CRN1
MSC-07HRN1
44
Corona Family_Multi
43
Corona Family_Single
MSCI-09HRN1
MSCI-12HRN1
Features:
Standard Optional
Specification:
Model
Model
Specification: Cooling Only Cooling & Heating
Model
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Indoor Unit
Outdoor Unit
mmAir FlowDimension WxHxD
Capacity Cooling/Heatingm3/hBtu/h
kgdB(A)
Packing WxHxDNet/Gross WeightIndoor noise level (Hi/Mi/Lo) Liquid side/Gas side
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor
Liquid SideGas Side
Btu/W.h, W/WW/W
m3/hA
3.62
52037/34/30
52
A AEnergy Rate
dB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
m2
kWHeating Btu/h
630(260-880)650(270-930)
820(290-1080)220-240, 50, 1
810(280-1110)1090(400-1360)220-240, 50, 1
1050(390-1400)Power Input Cooling Heating
WW
Electrical Parts
Capacity
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
MSJ-07HRDN1-QC2 MSJ-09HRDN1-QC2 MSJ-12HRDN1-QC2
MSJ-07CRN1-QB8 MSJ-07HRN1-QB8
MSJ-09CRN1-QB8 MSJ-09HRN1-QB8
MSJ-12CRN1-QB8 MSJ-12HRN1-QB8
MSJ-18CRN1-QB8 MSJ-18HRN1-QB8
DC Inverter
DC Inverter
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
WxHxDWxHxDIndoor/Outdoor
Indoor unitOutdoor unitGross Weight
Liquid SideGas Side
Btu/W.h, W/WW/W
m3/hEnergy Rate
dB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
m2
kWHeating Btu/h
70002.1
10.0,2.93-
37036/32/29
53
220-240, 50, 1
3.1-
10-14
132/250/292
700x535x235750x250x198
8/26
815x580x325840x340x270
10/28
Ø6.35(1/4")Ø9.53(3/8")
--
C
700-
70002.1
10.0,2.933.35
37036/32/29
53
220-240, 50, 1
3.13.1
10-14
132/250/292
700x535x235750x250x198
8/27
815x580x325840x340x270
10/29
Ø6.35(1/4")Ø9.53(3/8")
80002.3
C
700700
90002.6
9.8,2.87-
42037/32/29
54
220-240, 50, 1
4.0-
14-21
132/250/292
700x535x235750x250x198
8/27
815x580x325840x340x270
10/29
Ø6.35(1/4")Ø9.53(3/8")
--
C
920-
90002.6
9.8,2.873.21
42037/32/29
54
220-240, 50, 1
4.04.0
14-21
132/250/292
700x535x235750x250x198
8/28
815x580x325840x340x270
10/30
Ø6.35(1/4")Ø9.53(3/8")
100002.9
C
920910
120003.5
10.0,2.93-
60040/35/32
55
220-240, 50, 1
5.5-
18-26
108/218/270
780x540x250790x265x204
9.5/34
910x575x335875x375x285
11.5/36
Ø6.35(1/4")Ø12.7(1/2")
--
C
1200-
120003.5
10.0,2.933.44
60040/35/32
55
220-240, 50, 1
5.55.0
18-26
108/218/270
780x540x250790x265x204
9.5/35
910x575x335875x375x285
11.5/37
Ø6.35(1/4")Ø12.7(1/2")
130003.8
C
12001150
170005.0
9.6,2.813.21
85044/41/38
58
220-240, 50, 1
8.07.3
28-40
83/179/215
760x590x285920x293x227
11.5/42
872x640x3401005x305x370
15/45
Ø6.35(1/4")Ø12.7(1/2")
185005.4
C
17701690
170005.0
9.6,2.81-
85044/41/38
58
220-240, 50, 1
8.0-
28-40
83/179/215
760x590x285920x293x227
11.5/41
872x640x3401005x305x370
15/44
Ø6.35(1/4")Ø12.7(1/2")
--
C
1770-
Power Input CoolingHeating
WW
Electrical Parts
Capacity
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
WxHxDWxHxDIndoor/Outdoor
Indoor unitOutdoor unitGross Weight
Liquid SideGas Side
Btu/W.h, W/WW/W
m3/hEnergy Rate
dB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
m2
kWHeating Btu/h
260007.6
8.5, 2.50-
108047/44/41
57
220-240, 50, 1
13.9-
50-68
60/132/142
845x695x3351080x330x225
17/62
970x770x3951165x445x320
21/66
Ø9.53(3/8")Ø16.0(5/8")
--
E
3050-
260007.6
8.5, 2.502.84
108047/44/41
57
220-240, 50, 1
13.914.8
50-68
60/132/142
845x695x3351080x330x225
17/63
970x770x3951165x445x320
21/67
Ø9.53(3/8")Ø16.0(5/8")
310009.1
E
30503200
200005.9
9.1, 2.67-
80045/42/39
55
220-240, 50, 1
10.1-
34-49
66/142/163
845x695x335920x292x225
13/52
970x770x3951015x370x295
15/57
Ø9.53(3/8")Ø16.0(5/8")
--
D
2200-
200005.9
9.1, 2.672.81
80045/42/39
55
220-240, 50, 1
10.110.5
34-49
66/142/163
845x695x335920x292x225
13/55
970x770x3951015x370x295
15/60
Ø9.53(3/8")Ø16.0(5/8")
220006.4
D
22002300
230006.7
8.6,2.51-
102045/42/39
55
220-240, 50, 1
12.5-
45-56
60/132/142
845x695x3351080x330x225
17/59
970x770x3951165x445x320
21/63
Ø9.53(3/8")Ø16.0(5/8")
--
E
2680-
230006.7
8.6,2.512.81
102045/42/39
55
220-240, 50, 1
12.513.2
45-56
60/132/142
845x695x3351080x330x225
17/62
970x770x3951165x445x320
21/66
Ø9.53(3/8")Ø16.0(5/8")
280008.2
E
26802930
Power Input CoolingHeating
WW
Electrical Parts
Capacity
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor
Liquid SideGas Side
Btu/W.h, W/WW/W
m3/hD
2.82
50036/33/29
52
D DEnergy Rate
dB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
m2
kWHeating Btu/h
780(310-1010)940(320-1180)
1010(350-1220)220-240, 50, 1
1240(360-1490)1350(380-1590)220-240, 50, 1
1560(440-1830)Power Input Cooling Heating
WW
Electrical Parts
Capacity
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Indoor Unit
Outdoor Unit
mmAir FlowDimension WxHxD
Capacity Cooling/Heatingm3/hBtu/h
kgdB(A)
Packing WxHxDNet/Gross WeightIndoor noise level (Hi/Mi/Lo) Liquid side/Gas side
PackingNet/Gross WeightOutdoor air flowOutdoor noise level
mm
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Types of Indoor Unit Combinations
One Unit Two Units79
12
7+77+97+12
9+99+1212+12
Three Units7+7+77+7+97+7+12
7+9+97+9+127+12+12
9+9+99+9+129+12+12
One Unit Two Units79
12
7+77+97+12
9+99+1212+12
18 Types 9 Types
M2OA-18HRIN2
5459 - 18084 - 22519
220-240,50,1
1.6 - 5.3 - 6.67848 - 23543 - 25249
2.3 - 6.9 - 7.4
0.65 - 2.02 - 2.730.78 - 2.44 - 3.30
3.08 - 9.56 - 12.93 3.40 - 10.65 - 14.40
2.62-D2.83-D
845x695x335975x772x405
71/74250056
9383 - 26614 - 31732
220-240,50,1
2.75 - 7.8 - 9.310714 - 30708 - 36850
3.14 - 9.0 - 10.8
0.93 - 2.99 - 4.021.00 - 3.15 - 4.25
4.40 - 14.16 - 19.03 4.36 - 13.75 - 18.55
2.61-D2.86-D
845x695x335975x772x405
72/76250058
M3OA-27HRIN2
Remarks: One outdoor unit can drive 3 free-matched indoor units at most.
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
WxHxDWxHxDIndoor/Outdoor
Indoor unitOutdoor unitGross Weight
Liquid SideGas Side
Btu/W.h, W/WW/W
m3/hEnergy Rate
dB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
m2
kWHeating Btu/h
Power Input CoolingHeating
WW
Electrical Parts
Capacity
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
270007.9
8.4, 2.45-
115045/42/39
57
220-240, 50, 1
14.8-
50-68
60/127/142
845x695x3351080x330x222
17/63
970x770x3951165x445x320
22/68
Ø9.53(3/8")Ø16.0(5/8")
--
E
3230-
270007.9
8.4, 2.452.85
115045/42/39
57
220-240, 50, 1
14.815.1
50-68
60/127/142
845x695x3351080x330x222
17/64
970x770x3951165x445x320
22/69
Ø9.53(3/8")Ø16.0(5/8")
320009.4
E
32303290
280008.2
8.5, 2.49-
108047/44/41
57
380-420, 50, 3
5.8-
50-68
60/127/142
845x695x3351080x330x222
17/63
970x770x3951165x445x320
22/68
Ø9.53(3/8")Ø16.0(5/8")
--
E
3300-
280008.2
8.5, 2.492.93
108047/44/41
57
380-420, 50, 3
5.85.8
50-68
60/127/142
845x695x3351080x330x222
17/64
970x770x3951165x445x320
22/69
Ø9.53(3/8")Ø16.0(5/8")
330009.7
E
33003300
180005.3
8.7, 2.54-
80041/37/35
54
220-240, 50, 1
9.6-
34-49
66/142/163
845x695x335906x286x235
13.5/52
970x770x3951020x380x328
16.5/57
Ø9.53(3/8")Ø16.0(5/8")
--
E
2080-
180005.3
8.7, 2.542.87
80041/37/35
54
220-240, 50, 1
9.610.7
34-49
66/142/163
845x695x335906x286x235
13.5/55
970x770x3951020x380x328
16.5/60
Ø9.53(3/8")Ø16.0(5/8")
230006.7
E
20802350
230006.7
8.7, 2.54-
105043/40/37
56
220-240, 50, 1
12.1-
45-56
60/127/142
845x695x3351080x330x222
17/61
970x770x3951165x445x320
21/66
Ø9.53(3/8")Ø16.0(5/8")
--
E
2650-
230006.7
8.7, 2.542.96
105043/40/37
56
220-240, 50, 1
12.111.7
45-56
60/127/142
845x695x3351080x330x222
17/62
970x770x3951165x445x320
21/67
Ø9.53(3/8")Ø16.0(5/8")
260007.6
E
26502570
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
MSG-07/09/12CRN2
MSG-18/21/24/30/36CRN2
MSG-07/09/12HRN2
MSG-18/21/24/30/36HRN2
58 57
Glory Family_AC Inverter Glory Family_Multi
MSGI-09HRN2
MSGI-12HRN2
Features:
Standard Optional
Specification:
Model
Model
MSG-07HRIN2
MSG-12HRIN2
Features:
Standard Optional
MSG-09HRIN2
Specification:Model
Cooling Only Cooling & Heating
7000(2500-9000)2.1(0.7-2.6)
9.0, 2.632.81
45036/33/30
51
220-240, 50, 1
3.6(1.5-4.8)4.3(1.5-5.6)
10-14
113/238/274
780x540x250750x250x188
8.5/37780x540x250750x250x188
8.5/37780x540x250815x280x195
11/40
910x575x325830x336x280
11/40910x575x325830x336x280
11/40
Ø6.35(1/4")Ø9.53(3/8")
910x575x325915x360x275
14/43
Ø6.35(1/4")Ø9.53(3/8")
MSG-07HRIN2 MSG-09HRIN2 MSG-12HRIN2
9000(2900-10600)2.6(0.8-3.1)
8.1, 2.61
4.6(1.5-5.6)5.7(1.7-7.2)
14-21
113/238/274
12000(3400-14100)3.5(1.0-4.1)
8.1, 2.612.81
58037/34/31
53
6.2(1.8-7.5)7.1(2.1-8.6)
18-26
108/226/264
Ø12.7(1/2")Ø6.35(1/4")
9000(2700-11100)2.6(0.8-3.3)
12000(3300-14000)3.5(1.0-4.1)
15000(4200-17600)4.4(1.2-5.2)
Operating Current Cooling Heating
Outdoor
kW
V~,Hz,Ph
AA
Cooling
Voltage,Frequency,Phase
Btu/h
20'/40'/40'HQ
EERCOP
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor
Liquid SideGas Side
Btu/W.h, W/WW/W
m3/hD
2.82
50036/33/30
51
D DEnergy Rate
dB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
m2
kWHeating Btu/h
780(310-1010)940(320-1180)
1010(350-1220)220-240, 50, 1
1240(360-1490)1350(380-1590)220-240, 50, 1
1560(440-1830)Power Input Cooling Heating
WW
Electrical Parts
Capacity
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Indoor Unit
Outdoor Unit
mmAir FlowDimension WxHxD
Capacity Cooling/Heatingm3/hBtu/h
kgdB(A)
Packing WxHxDNet/Gross WeightIndoor noise level (Hi/Mi/Lo) Liquid side/Gas side
EERCOPDimension WxHxDPacking WxHxDNet/Gross WeightOutdoor air flowOutdoor noise level
W/WW/Wmmmmkg
m3/hdB(A)
Power Input Cooling/Heating W
Electrical Data
Capacity
Performance
Remarks: One outdoor unit can drive 3 free-matched indoor units at most.
500 520
35
560
J
62 61
MSQ3-07/09/12HRDN1-QC2
MOC-07/09/12HDN1-QC2
Features:
Standard Optional
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Cooling Only Cooling & Heating Specification:
Model
Power Input Cooling HeatingOperating Current Cooling Heating
Fresh AirMidea air conditioner have a pump in the indoor unit, when press the "Fresh Air" button, the pump suck the fresh air from outside, and the indoor polluted air flow out of the room via the air pressure.
The ceiling temperature is often higher than the floor temperature. For example, floor temp. is 21ºC, while ceiling temp may be 25ºC. By adopting temp. compensation function, the temperature difference can be eliminated. So if you set temp for 21ºC, the air-conditioner may make intelligent temp compensation, setting the ceiling temp for 25ºC, to ensure the floor temp of 21ºC.
Vitamin C FilterVitamin C is one of necessary material for human being, and it is also good for human skin. Vitamin C Filter is made of Vitamin C Emission material. When the air flows through it, the Vitamin C will be taken everywhere in the room.
(Optional)
6hours 12hours 18hours 24hours0.0
1.00.90.80.70.60.50.40.30.20.1
Conc
entra
tion
of A
scor
bic A
cid (m
g/L)
Progress of “Vitamin-C emission” every 6 hours
0.70
0.65
0.60
0.55
0.50
0.45
0.40
0.30
0.35
1day 2days 3days 4days 5days 6days
Conc
entra
tion
of A
scor
bic A
cid (m
g/L)
Performance of the emission in case of continuous running
DC Inverter
64 63
CSU-09/12YHR3BA
CSU-18YHR3AB
CSU-21/24YHR3AA
Features:
Standard Optional
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Cooling Only Cooling & Heating Specification:
Model
Power Input Cooling HeatingOperating Current Cooling Heating
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor
Liquid SideGas Side
Btu/W.h, W/WW/W
m3/hdB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
m2
90002.6
11.3,3.30
480
3.50
37/32/2852
220-240, 50, 17608103.63.9
920x615x390
14-21
90/188/210
780x540x255815x290x203
9/35
Ø6.35(1/4")Ø9.53(3/8")
100002.9
850x345x300
12/39
A
CSU-09YHR3BA
120003.5
11.3,3.30
480
3.50
37/32/2852
220-240, 50, 1106010005.04.5
920x615x390
18-26
90/188/210
780x540x255815x290x203
9/39
Ø6.35(1/4")Ø12.7(1/2")
130003.8
850x345x300
12/44
A
CSU-12YHR3BA
170005.0
10.5,3.10
700
3.30
43/38/3453
220-240, 50, 1158015107.47.3
920x615x390
28-40
84/186/205
780x540x2551015x320x190
14/40
Ø6.35(1/4")Ø12.7(1/2")
180005.3
1050x370x290
17/44
B
CSU-18YHR3AB
190005.6
9.9,2.90
700
3.20
43/38/3453
220-240, 50, 1193018408.88.4
1010x695x430
34-49
70/140/170
850x605x2901015x320x190
14/47
Ø9.53(3/8")Ø16.0(5/8")
200005.9
1050x370x290
17/51
C
CSU-21YHR3AA
210006.1
9.9,2.90
750
3.10
46/39/3558
220-240, 50, 1211019209.78.8
1010x695x430
45-56
70/140/170
850x605x2901015x320x190
14/53
Ø9.53(3/8")Ø16.0(5/8")
210006.1
1050x370x290
17/58
C
CSU-24YHR3AA
Vita220-240V~,50Hz
Silver lon Filter (Optional) The Silver ion can kill bacteria or prevent their activity at very low density by destroying their inner- configuration and absorbing their elements in cells. Meanwhile, the Nano Silver attached on the filter release the Silver ion constantly to eliminate bacteria effectively and continuously.
CSU-09YHR3BA CSU-18YHR3AB
CSU-24YHR3AA
CSU-12YHR3BA
CSU-21YHR3AA
Vitamin C FilterVitamin C is one of necessary material for human being, and it is also good for human skin. Vitamin C Filter is made of Vitamin C Emission material. When the air flows through it, the Vitamin C will be taken everywhere in the room.
(Optional)
6hours 12hours 18hours 24hours0.0
1.00.90.80.70.60.50.40.30.20.1
Conc
entra
tion
of A
scor
bic A
cid (m
g/L)
Progress of “Vitamin-C emission” every 6 hours
0.70
0.65
0.60
0.55
0.50
0.45
0.40
0.30
0.35
1day 2days 3days 4days 5days 6days
Conc
entra
tion
of A
scor
bic A
cid (m
g/L)
Performance of the emission in case of continuous running
66 65
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Helit220-240V~,50Hz
CSU-07HHR3AA CSU-09HHR3AB CSU-12HHR3AB
CSU-18HHR3AB CSU-21HHR3AA CSU-24HHR3AA
Silver lon Filter (Optional)
The Silver ion can kill bacteria or prevent their activity at very low density by destroying their inner- configuration and absorbing their elements in cells. Meanwhile, the Nano Silver attached on the filter release the Silver ion constantly to eliminate bacteria effectively and continuously.
CSU-07HHR3AA
CSU-09/12/18HHR3AB
CSU-21/24HHR3AA
Features:
Standard Optional
Specification:Model
Cooling Only Cooling & Heating
Operating Current CoolingHeating
Outdoor
kW
V~,Hz,Ph
AA
Cooling
Voltage,Frequency,Phase
Btu/h
20'/40'/40'HQ
EERCOP
Air Flow Volume IndoorNoise Level Indoor(Hi/Med/Lo)
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
WxHxDWxHxDIndoor/Outdoor
Indoor unitOutdoor unitGross Weight
Liquid SideGas Side
Btu/W.h, W/WW/W
m3/hEnergy Rate
dB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
m2
kWHeating Btu/h
CSU-07HHR3AA
70002.1
11.2,3.303.50
41035/32/26
52
220-240, 50, 1
2.93.1
10-14
126/270/322
600x502x232740x243x200
7/23
735x565x370785x295x260
9/26
Ø6.35(1/4")Ø9.53(3/8")
75002.2
A
610630
CSU-09HHR3AB
90002.6
11.2,3.303.45
43037/32/26
52
220-240, 50, 1
3.63.7
14-21
116/232/264
710x540x255740x243x200
7/25
825x607x375785x295x260
9/31
Ø6.35(1/4")Ø9.53(3/8")
100002.9
A
800830
CSU-12HHR3AB
120003.5
11.2,3.303.45
50039/34/29
52
220-240, 50, 1
5.15.2
18-26
108/220/250
780x540x255815x275x200
9/35
920x615x390838x326x260
12/39
Ø6.35(1/4")Ø12.7(1/2")
130003.8
A
10801070
CSU-18HHR3AB
170005.0
10.4,3.053.20
70043/38/34
53
220-240, 50, 1
7.37.1
28-40
84/186/205
780x540x2551015x320x190
14/40
920x615x3901050x370x290
17/44
Ø6.35(1/4")Ø12.7(1/2")
180005.3
B
16501560
CSU-21HHR3AA
190005.6
9.7,2.863.05
70043/38/34
53
220-240, 50, 1
8.98.8
34-49
70/140/170
850x605x2901015x320x190
14/47
1010x695x4301050x370x290
17/51
Ø9.53(3/8")Ø16.0(5/8")
200005.9
C
19601940
CSU-24HHR3AA
210006.1
9.6,2.832.90
75045/39/35
53
220-240, 50, 1
9.89.6
45-56
70/140/170
850x605x2901015x320x190
14/53
1010x695x4301050x370x290
17/58
Ø9.53(3/8")Ø16.0(5/8")
210006.1
C
21602100
Power Input CoolingHeating
WW
Electrical Parts
Capacity
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
Vitamin C FilterVitamin C is one of necessary material for human being, and it is also good for human skin. Vitamin C Filter is made of Vitamin C Emission material. When the air flows through it, the Vitamin C will be taken everywhere in the room.
(Optional)
6hours 12hours 18hours 24hours0.0
1.00.90.80.70.60.50.40.30.20.1
Conc
entra
tion
of A
scor
bic A
cid (m
g/L)
Progress of “Vitamin-C emission” every 6 hours
0.70
0.65
0.60
0.55
0.50
0.45
0.40
0.30
0.35
1day 2days 3days 4days 5days 6days
Conc
entra
tion
of A
scor
bic A
cid (m
g/L)
Performance of the emission in case of continuous running
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor
Liquid SideGas Side
Btu/W.h, W/WW/Wm3/h
dB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
m2
24000/27000+72007.1/7.9+2.1
220-240,50, 12500/24502640+2100
12/11.5+10
9.6,2.83.2
110048/42
60
500x1700x290840x695x335
41.5/60
615x1805x415965x755x395
58.5/63
Ø9.53(3/8")Ø16.0(5/8")
40-56
35/76/89
MFJ-24ARN1-QB8
48000/49000+1200014.0/14.4+3.5
380,50, 35400/5100+3500
8.6/8.5+5.8
8.9,2.62.8
175050/44
62
540x1825x410940x1245x360
58/104
655x1935x5551018x1380x435
75/115
Ø12.7(1/2")Ø19.0(3/4")
80-112
16/36/51
MFJ-48ARN1-RB6
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Cooling Only Cooling & Heating Specification:
Power Input Cooling/HeatingOperating Current Cooling/Heating
Indoor unit WxHxDOutdoor unit WxHxDNet Weight Indoor/Outdoor
Indoor unit WxHxDOutdoor unit WxHxDGross Weight Indoor/Outdoor
Liquid SideGas Side
Net Dimension & Weight
Packing Dimension & Gross Weight
Piping Connection
Applicable Area
Stuffing Quantity
Performance
kW
V~,Hz,PhWA
Btu/h
Btu/W.h, W/WW/Wm3/hdB(A)dB(A)
mmmmkg
mmmmkg
mm(inch)mm(inch)
Set
m2
240007.1
220-240,50,1
12.5
8.3,2.4
10004558
500x1665x273840X695X335
46/63
585x1805x380965x772x395
57/67
Ø9.53(3/8")Ø16.0(5/8")
40-56
43/87/97
2900
MFS2-24CRN2
240007.1
380,50,3
5.2
8.3,2.4
10004558
500x1665x273840X695X335
46/66
585x1805x380965x772x395
57/70
Ø9.53(3/8")Ø16.0(5/8")
40-56
43/87/97
2900
MFS2-24CRN2
24000/290007.1/8.5
220-240,50,1
12.5/12.5
8.3,2.42.8
10004558
500x1665x273840X695X335
46/64
585x1805x380965x772x395
57/68
Ø9.53(3/8")Ø16.0(5/8")
40-56
43/87/97
2900/2900
MFS2-24HRN2
24000/29000+72007.1/8.5+2.1
220-240,50,1
12.5/12.5+10
8.3,2.42.8
10004558
500x1665x273840X695X335
46/64
585x1805x380965x772x395
57/68
Ø9.53(3/8")Ø16.0(5/8")
40-56
43/87/97
2900/2900+2100
MFS2-24ARN2
24000/29000+85007.1/8.5+2.5
380,50,3
5.2/5.2+4.4
8.3,2.42.8
10004558
500x1665x273840X695X335
46/64
585x1805x380965x772x395
57/68
Ø9.53(3/8")Ø16.0(5/8")
40-56
43/87/97
2900/2900+2500
MFS2-24ARN2
4800014.0
380,50,3
9
8.3,2.4
20004860
540x1775x379940x1245x360
56/99
665x1915x4751018x1380x434
71/109
Ø12.7(1/2")Ø19.0(3/4")
80-112
22/46/54
5500
MFS2-48CRN2
48000/53000+1200014.0/15.5+3.5
380,50,3
9/9+5.8
8.3,2.42.8
20004860
540x1775x379940x1245x360
58/110
665x1915x4751018x1380x434
73/120
Ø12.7(1/2")Ø19.0(3/4")
80-112
22/46/54
5500/5500+3500
MFS2-48ARN2
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Cooling Only Cooling & Electric Heater Specification:
Model
Operating Current Cooling/Heater
kW
V~,Hz,Ph
A
Cooling/Heater
Power Supply
Btu/h
20'/40'/HQ
EER
Air Flow Volume IndoorNoise Level Hi/Med/Lo
Net Dimension WxHxDPacking Dimension WxHxDNet/Gross Weight
Btu/W.hW/W
m3/h
Energy RateMoisture Removal l/h
dB(A)
mmmmkg
Set
m2
Power Input Cooling/Heater W
Electrical Data
Capacity
Dimension & Weight
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Cooling Only Cooling & Electric Heater Specification:
Model
Operating Current Cooling/Heater
kW
V~,Hz,Ph
A
Cooling/Heater
Power Supply
Btu/h
20'/40'HQ
EER
Air Flow Volume IndoorNoise Level Hi/Med/Lo
Net Dimension WxHxDPacking Dimension WxHxDNet/Gross Weight
Btu/W.hW/W
m3/h
Energy RateMoisture RemovalWater Tank Volume
l/hL
dB(A)
mmmmkg
Set
m2
Power Input Cooling/Heater W
Electrical Data
Capacity
Dimension & Weight
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Cooling Only Cooling & Electric Heater Specification:
Model
Operating Current Cooling/Heater
kW
V~,Hz,Ph
A
Cooling/Heater
Power Supply
Btu/h
20'/40'HQ
EER
Air Flow Volume IndoorNoise Level Hi/Med/Lo
Net Dimension WxHxDPacking Dimension WxHxDNet/Gross Weight
Btu/W.hW/W
m3/h
Energy RateMoisture Removal l/h
dB(A)
mmmmkg
Set
m2
Power Input Cooling/Heater W
Electrical Data
Capacity
Dimension & Weight
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
70002.0
220-240,50,17503.3
9.32.73
A1.5410
53/50/48
480x836x385725x885x460
38/50
10-14
80/245
MPM1-07CRN1-QB6 MPM1-07CEN1-QB6
7000/60002.0/1.7
220-240,50,1750/18003.3/7.8
9.32.73
A1.5410
53/50/48
480x836x385725x885x460
38/50
10-14
80/245
MPM1-07ERN1-QB6 MPM1-07EEN1-QB6
90002.6
220-240,50,19504.2
9.472.77
A1.6460
54/51/49
480x836x385725x885x460
40/52
14-21
80/245
MPM1-09CRN1-QB6 MPM1-09CEN1-QB6
9000/60002.6/1.7
220-240,50,1950/18004.2/7.8
9.472.77
A1.6460
54/51/49
480x836x385725x885x460
40/52
14-21
80/245
MPM1-09ERN1-QB6 MPM1-09EEN1-QB6
120003.5
220-240,50,113806.1
8.92.6B
1.8520
56/52/50
480x836x385725x885x460
43/55
18-26
80/245
MPM1-12CRN1-QB4 MPM1-12CEN1-QB4
12000/60003.5/1.7
220-240,50,11380/1800
6.1/7.8
8.92.6B
1.8520
56/52/50
480x836x385725x885x460
43/55
18-26
80/245
MPM1-12ERN1-QB4 MPM1-12EEN1-QB4
74 73
Model
Operating Current Cooling/Heater
kW
V~,Hz,Ph
A
Cooling/Heater
Power Supply
Btu/h
20'/40'HQ
EER
Air Flow Volume IndoorNoise Level Hi/Med/Lo
Net Dimension WxHxDPacking Dimension WxHxDNet/Gross Weight
Btu/W.hW/W
m3/h
Energy RateMoisture RemovalWater Tank Volume
l/hL
dB(A)
mmmmkg
Set
m2
Power Input Cooling/Heater W
Electrical Data
Capacity
Dimension & Weight
Applicable Area
Stuffing Quantity
Performance
MPK-07CEN1-QB6 MPK-07EEN1-QB6
Electronic Control
MPK-07CRN1-QB6 MPK-07ERN1-QB6
Remote Control
PTC HeaterFlexibleExhaust Hose
AdjustableWindow Slider Kit
Flexible ExhaustThrough the Wall
or Window
LED DisplayShowerCooling System
Silver Ion(Optional)
Bio Filter(Optional)
Vitamin C Filter(Optional)
Features:
MPK2-12CEN1-QB4 MPK2-12EEN1-QB4
Electronic Control
MPK-09CEN1 MPK-09EEN1
MPK-09CRN1 MPK-09ERN1
MPK2-09CEN1-QB6 MPK2-09EEN1-QB6
MPK2-09CRN1-QB6 MPK2-09ERN1-QB6
MPK2-12CRN1-QB4 MPK2-12ERN1-QB4
MPK2-10CEN1-QB6 MPK2-10EEN1-QB6
MPK2-10CRN1-QB6 MPK2-10ERN1-QB6
Remote Control
Cooling Only Cooling & Electric Heater Specification:
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
90002.6
220-240,50,19504.2
9.52.77
A1.73.5460
53/50/48
460x840x370705x885x455
38/50
14-21
82/250
MPK2-09CRN1-QB6 MPK2-09CEN1-QB6
9000/60002.6/1.7
220-240,50,1950/18004.2/7.8
9.52.77
A1.73.5460
53/50/48
460x840x370705x885x455
38/50
14-21
82/250
MPK2-09ERN1-QB6 MPK2-09EEN1-QB6
K Portable220-240V~,50Hz
Cooling Only Cooling & Electric Heater Specification:
Model
Operating Current Cooling/Heater
kW
V~,Hz,Ph
A
Cooling/Heater
Power Supply
Btu/h
20'/40'HQ
EER
Air Flow Volume IndoorNoise Level Hi/Med/Lo
Net Dimension WxHxDPacking Dimension WxHxDNet/Gross Weight
Btu/W.hW/W
m3/h
Energy RateMoisture RemovalWater Tank Volume
l/hL
dB(A)
mmmmkg
Set
m2
Power Input Cooling/Heater W
Electrical Data
Capacity
Dimension & Weight
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
100003.0
220-240,50,110404.6
9.62.81
A1.73.5460
53/50/48
460x840x370705x885x455
39/50
15-25
82/250
MPK1-10CRN1-QB6 MPK1-10CEN1-QB6
10000/60003.0/1.7
220-240,50,11040/1800
4.6/7.8
9.62.81
A1.73.5460
53/50/48
460x840x370705x885x455
39/50
15-25
82/250
MPK1-10ERN1-QB6 MPK1-10EEN1-QB6
120003.5
220-240,50,113806.1
8.72.54
B1.83.5520
54/51/49
460x840x370705x885x455
41/52
18-26
82/250
MPK1-12CRN1-QB4 MPK1-12CEN1-QB4
12000/60003.5/1.7
220-240,50,11380/1800
6.1/7.8
8.72.54
B1.83.5520
54/51/49
460x840x370705x885x455
41/52
18-26
82/250
MPK1-12ERN1-QB4 MPK1-12EEN1-QB4
90002.6
220-240,50,110404.5
8.72.53
B1.63.5360
52/50/48
460x840x325680x880x400
33/44
14-21
96/295
MPK-09CRN1 MPK-09CEN1
9000/60002.6/1.7
220-240,50,11040/1800
4.5/7.8
8.72.53
B1.63.5360
52/50/48
460x840x325680x880x400
33/44
14-21
96/295
MPK-09ERN1 MPK-09EEN1
70002.0
220-240,50,17703.3
9.12.66
A1.53.5360
52/50/48
460x840x325680x880x400
33/44
10-14
96/295
MPK-07CRN1-QB6 MPK-07CEN1-QB6
7000/60002.0/1.7
220-240,50,1770/18003.3/7.8
9.12.66
A1.53.5360
52/50/48
460x840x325680x880x400
33/44
10-14
96/295
MPK-07ERN1-QB6 MPK-07EEN1-QB6
76 75
PTC HeaterFlexibleExhaust Hose
AdjustableWindow Slider Kit
Flexible ExhaustThrough the Wall
or Window
LED DisplayShowerCooling System
Silver Ion(Optional)
Bio Filter(Optional)
Vitamin C Filter(Optional)
Features:
Ionizer(Optional)
PTC HeaterFlexibleExhaust Hose
AdjustableWindow Slider Kit
Flexible ExhaustThrough the Wall
or Window
LED DisplayShowerCooling System
Silver Ion(Optional)
Bio Filter(Optional)
Vitamin C Filter(Optional)
Features:
MPK-10CEN2 MPK-10EEN2
Electronic Control
MPK-10CRN2 MPK-10ERN2
Remote Control
K Portable220-240V~,50Hz
Cooling Only Cooling & Electric Heater Specification:
Model
Operating Current Cooling/Heater
kW
V~,Hz,Ph
A
Cooling/Heater
Power Supply
Btu/h
20'/40'HQ
EER
Air Flow Volume IndoorNoise Level Hi/Med/Lo
Net Dimension WxHxDPacking Dimension WxHxDNet/Gross Weight
Btu/W.hW/W
m3/h
Energy RateMoisture RemovalWater Tank Volume
l/hL
dB(A)
mmmmkg
Set
m2
Power Input Cooling/Heater W
Electrical Data
Capacity
Dimension & Weight
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
100003.0
220-240,50,111605.1
8.62.52
C1.63.5380
52/50/48
460x840x325680x880x400
34/41
34/41
96/295
MPK-10CRN2 MPK-10CEN2
10000/60003.0/1.7
220-240,50,11160/1800
5.1/7.8
8.62.52
C1.63.5380
52/50/48
460x840x325680x880x400
34/41
34/41
96/295
MPK-10ERN2 MPK-10EEN2
Cooling Only Cooling & Electric Heater Specification:
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
100003.0
220-240,50,110404.6
9.62.81
A1.83.5460
53/50/48
460x840x370705x885x455
38/50
15-25
82/250
MPK2-10CRN1-QB6 MPK2-10CEN1-QB6
10000/60003.0/1.7
220-240,50,11040/1800
4.6/7.8
9.62.81
A1.83.5460
53/50/48
460x840x370705x885x455
38/50
15-25
82/250
MPK2-10ERN1-QB6 MPK2-10EEN1-QB6
120003.5
220-240,50,113806.1
8.72.54
B2.03.5520
54/50/48
460x840x370705x885x455
40/51
18-26
82/250
MPK2-12CRN1-QB4 MPK2-12CEN1-QB4
12000/60003.5/1.7
220-240,50,11380/1800
6.1/7.8
8.72.54
B2.03.5520
54/50/48
460x840x370705x885x455
40/51
18-26
82/250
MPK2-12ERN1-QB4 MPK2-12EEN1-QB4
90002.6
220-240,50,19504.2
9.52.77
A1.73.5460
53/50/48
460x840x370705x885x455
38/50
14-21
82/250
MPK2-09CRN1-QB6 MPK2-09CEN1-QB6
9000/60002.6/1.7
220-240,50,1950/18004.2/7.8
9.52.77
A1.73.5460
53/50/48
460x840x370705x885x455
38/50
14-21
82/250
MPK2-09ERN1-QB6 MPK2-09EEN1-QB6
Model
Operating Current
kW
V~,Hz,Ph
A
Cooling/Heater
Power Supply
Btu/h
20'/40'HQ
EER
Air Flow VolumeNoise Level
Net DimensionPacking DimensionNet/Gross Weight
Btu/W.hW/W
m3/h
Energy RateMoisture RemovalWater Tank Volume
l/hL
dB(A)
mmmmkg
Set
m2
Power Input
Electrical Data
Capacity
Dimension & Weight
Applicable Area
Stuffing Quantity
Performance
Cooling/HeaterCooling/Heater
IndoorHi/Med/Lo
WxHxDWxHxD
W
78 77
Cooling Only Cooling & Electric Heater Specification:
Model
Operating Current Cooling/Heater
kW
V~,Hz,Ph
A
Cooling/Heater
Power Supply
Btu/h
20'/40'HQ
EER
Air Flow Volume IndoorNoise Level Hi/Med/Lo
Net Dimension WxHxDPacking Dimension WxHxDNet/Gross Weight
Btu/W.hW/W
m3/h
Energy RateMoisture RemovalWater Tank Volume
l/hL
dB(A)
mmmmkg
Set
m2
Power Input Cooling/Heater W
Electrical Data
Capacity
Dimension & Weight
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Cooling Only Cooling & Electric Heater Specification:
Model
Operating Current Cooling/Heater
kW
V~,Hz,Ph
A
Cooling/Heater
Power Supply
Btu/h
20'/40'HQ
EER
Air Flow Volume IndoorNoise Level Hi/Med/Lo
Net Dimension WxHxDPacking Dimension WxHxDNet/Gross Weight
Btu/W.hW/W
m3/h
Energy RateMoisture RemovalWater Tank Volume
l/hL
dB(A)
mmmmkg
Set
m2
Power Input Cooling/Heater W
Electrical Data
Capacity
Dimension & Weight
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Sliding ChassisFresh Air Switch Silver lon(Optional)
Features:
MWF-09HMN2 MWF-12HMN2 MWF-16HMN2 MWF-18HMN2
MWF-09HRN2 MWF-12HRN2 MWF-16HRN2 MWF-18HRN2
Cooling Only Cooling & Heating Specification:
Model
Operating Current Cooling
kW
V~,Hz,Ph
A
Cooling
Power Supply
Btu/h
20'/40HQ
EERCOP
Air Flow Volume IndoorNoise Level Indoor(Hi/Lo)
Net Dimension WxHxDPacking Dimension WxHxDNet/Gross Weight
Btu/W.hW/W
m3/hEnergy Rate Cooling
dB(A)
mmmmkg
Set
m2
Power Input Cooling W
Electrical Data
Capacity
Dimension & Weight
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.
90002.6
220-230,50,110504.7
8.462.48
D420
51/45
450x346x535495x435x580
35/39
14-20
220/572
MWF-09CRN2 MWF-09CMN2
120003.5
220-230,50,113505.8
8.842.59
D530
53/47
600x380x560690x445x620
43/47
18-26
136/345
MWF-12CRN2 MWF-12CMN2
160004.7
220-230,50,119188.34
8.362.45
D660
55/50
660x435x640750x520x740
55/60
21-35
94/240
MWF-16CRN2 MWF-16CMN2
180005.3
220-230,50,121639.41
8.362.45
D660
55/50
660x435x640750x520x740
55/60
30-40
94/240
MWF-18CRN2 MWF-18CMN2
210006.2
220-230,50,12531
11
8.362.45
D920
59/55
660x430x770775x518x917
68/77
35-50
72/192
MWF-21CRN2 MWF-21CMN2
Cooling Only Cooling & Heating Specification:
Model
Operating Current Cooling/Heating
kW
V~,Hz,Ph
A
Cooling/Heating
Power Supply
Btu/h
20'/40'HQ
EERCOP
Air Flow Volume IndoorNoise Level Indoor(Hi/Lo)
Net Dimension WxHxDPacking Dimension WxHxDNet/Gross Weight
Btu/W.hW/W
m3/hEnergy Rate Cooling/Heating
dB(A)
mmmmkg
Set
m2
Power Input Cooling/Heating W
Electrical Data
Capacity
Dimension & Weight
Applicable Area
Stuffing Quantity
Performance
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement.2.The values given in the table for the noise level reflect the levels in anechoic chamber.