Btu/h Btu/h Voltage, Hz, Phase m3/h dB(A) mm mm mm mm kg kg kg Pieces Pieceskg Btu/h Btu/h Voltage, Hz, Phase m3/h dB(A) mm mm mm mm kg kg kg Pieces Pieceskg
FeaturesWiden the energy adjustment range: from 10%-100%.
Real stepless energy adjustment.
Long life span: PWM soloenoid valve can be used 40 billion times on average, equal to 30 years lifespan.
High efficiency and stability of the refrigerant compressed by applying the axial compliant sealing technology.
•
•
•
•
Development of Digital Scroll System
In 2002, the rollout of MDV-D Series has made Midea the leader of the industry.
In 2003, the launch of MDV-D Series has fully demonstrated the leading power of Midea. The MDV-DModulation System is a perfect application of Digital Scroll Technology. It simplifies the A/C system, saves more energy, and guarantees a stable performance.
R410A
R410A R22R407C
Ceiling & floor
Long pipe, wide height difference
No electromagnetic Disturbance
Operation Principle Of Digital Scroll Compressor
150m
50m
15m
the max.pipe length between indoor unit and outdoor unit
the max.height difference between indoor unit and outdoor unit
the max.height difference between indoor units
Advanced Oil Return Technology
Accurate Temperature Control
Constant T emperature
Temperature control accuracy of MDV: *0.5*
Temperature control accuracy of ordinary air conditioner: *3*
(Time)
Digital Scroll A/C System
33 34
The digital scroll compressor which utilizes the axial
compliant sealing technology precisely adjust the axial
moving range of the stator scroll pan. And there is an
additional connecting by-pass between the suction inlet
and the pressure bore at the floating sealing point of
axial stator.
When the PWM solenoid valve is open, the pressure in
the pressure bore is released. The pressure in the
compression bore is higher than that top of the stator,
then the stator axis of the compressor will move upward
a little. So high pressure bore and low pressure inlet is
connected and the unloading is achieved.
When the PWM solenoid valve is closed, two stators
engaged. Then the airproof and loading is achieved. The
compressor can adjust the ratio of ONs to OFFs freely
to control the refrigerant output of the compressor.
•
•
•
MDV Digital Scroll System causes no
electromagnetic disturbance, since the loading
and unloading of compressor are merely
mechanical movements. This special feature
makes the Digital Scroll System applicable to
telecommunication companies, power stations,
and all kinds of precise science labs.
•
A
Electromagnetic Comparison Between Digital And Inverter
0 1 2 3 4 5
5 th7 th
11 th13 th17 th19 th
E
M
W
Inverter EMC Standard Digital
Precise Science Lab CommunicationComputer Lab
TV & Radio Receiver Station
The Digital Scroll Compressor is in the state of loading or unloading. In the loading state, the full speed
operation of the compressor motor ensures the refrigerant has enough power to bring the oil back to the
compressor. In the unloading state, there is no oil moving out of the compressor since there is no refrigerant
output, the inertia of the refrigerant can also bring some oil back to the compressor.
•
Combining the electronic control and the mechanical control, the oil level controller keeps an appropriate
oil level in the compressor crankcase. Equipped with alarm system, it is applicable to both low-pressure
& high pressure oil cycling system.
•
Compared with the traditional
central air conditioning system,
MDV System can reach a 0.5
Degree Centigrade accuracy.
•
Digital scroll system is the only system that is free of oil separator
and oil recycling equipment. In the loading status, the speed
of the refrigerant is enough to move oil back to the compressor.In
the unloading status, no refrigerant pump out, no oil out of
compressor.
•
150m
50m15m
Outdoor Unit
Cooling & Heating
Outdoor Unit
Digital Scroll A/C System
Outdoor Unit
35 36
8
10
12
14
16
8+10
10+10
10+12
10+14
10+16
12+16
14+16
16+16
10x2+14
10x2+16
10+12+16
10+14+16
10+16x2
12+16x2
14+16x2
16x3
12x3+14
12x3+16
12x2+14+16
12x2+16x2
10+16x3
12+16x3
14+16x3
16x4
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
13
16
16
16
20
20
20
20
20
20
20
32
32
32
32
32
40
40
40
40
40
50
50
50
50
50
64
64
64
MDV-D252W/CS(N2)(N1)
MDV-D280W/CS(N2)(N1)
MDV-D335W/CS(N2)(N1)
MDV-D400W/CS(N2)(N1)
MDV-D450W/CS(N2)(N1)
MDV-D532W/CS(N2)(N1)
MDV-D560W/CS(N2)(N1)
MDV-D615W/CS(N2)(N1)
MDV-D680W/CS(N2)(N1)
MDV-D730W/CS(N2)(N1)
MDV-D785W/CS(N2)(N1)
MDV-D850W/CS(N2)(N1)
MDV-D900W/CS(N2)(N1)
MDV-D960W/CS(N2)(N1)
MDV-D1010W/CS(N2)(N1)
MDV-D1065W/CS(N2)(N1)
MDV-D1130W/CS(N2)(N1)
MDV-D1180W/CS(N2)(N1)
MDV-D1235W/CS(N2)(N1)
MDV-D1300W/CS(N2)(N1)
MDV-D1350W/CS(N2)(N1)
MDV-D1405W/CS(N2)(N1)
MDV-D1455W/CS(N2)(N1)
MDV-D1520W/CS(N2)(N1)
MDV-D1570W/CS(N2)(N1)
MDV-D1630W/CS(N2)(N1)
MDV-D1685W/CS(N2)(N1)
MDV-D1750W/CS(N2)(N1)
MDV-D1800W/CS(N2)(N1)
Capacity(HP) Model Combination Indoor unit connected
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
R410A
R407C
R22
28.031.5
25.227.0
380,50,3
980x1630x8001040x1780x840
1751550
1000058
245260
1-drive-1314/28/28
SystemMatch Configuration
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxDPacking WxHxD
NetGross
kWkW
m3/hdB(A)
mmmm
kgkg
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
Piping Connection
CoolingHeatingElectrical Data
Max Length of pipeMax Height Difference Between indoor units Between indoor units and outdoor unit
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
Outdoor Unit
Digital Scroll A/C System
Model Refrigerant Capacity
R410A R407C R22
R407C R22
R410A
R410A R407C R22
R410A R407C R22
R410A R407C R22
280
R410A R407C R22
R410A R407C R22
R410A R407C R22
R410A R407C R22
R410A R407C R22
R410A R407C R22
R410A R407C R22
R410A R407C R22
37 38
R407C
R22
Four-way cassette
Four-way cassette (compact)
High static pressure duct
One-way cassette
One-way cassette(compact)
Wall-mounted(compact)
Wall-mounted
High static pressure duct
Duct
Low Static PressureDuct
Floor Standing
Concealed Floor Standing
The Digital Scroll A/C System and Inverter Commercial A/C System have the same specification of indoor unit.
Ceiling & floor
R410A
997x1920x8801105x2120x1034
1000058
245260
IMDV-D100W/(S)N1 IMDV-D140W/SN1 IMDV-D280W/BSN1
28.031.5
1-drive-1610/20/20
1751550
Model
SystemMatch Configuration
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxDPacking WxHxD
NetGross
kWkW
m3/hdB(A)
mmmm
kgkg
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
Piping Connection
CoolingHeatingElectrical Data
Max Length of pipeMax Height Difference Between indoor units
Max Length of pipeMax Height Difference Between indoor units
Between indoor units and outdoor unit
MaxQty per 20'/40'/40'HQ
500054
Pieces
220-240,50,1
997x1920x8801105x2120x1034
1000058
245260
28.031.5
1-drive-1610/20/20
1501550
56.064.0
2000060
1992x1920x8802110x2120x1034
520525
1-drive-204/10/10
84.095.0
2987x1920x8803105x2120x1034
3000062
780785
1-drive-322/6/6
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
Indoor Unit (Q4)
Cooling & Heating
Digital Scroll A/C System
Indoor Unit (Q1)
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
Indoor Unit (T3)
Indoor Unit (T2)
39 40
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxD BodyPanel
Packing WxHxD Body Panel
Net Body/PanelGross Body/PanelQty per 20'/40'/40'HQ Indoor
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
Cooling & Heating
Indoor Unit (DL)
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
MDV Inverter Commercial A/C System is a direct expansion system, and it simplifies the complicated installation process and makes the maintenance easy.
Advanced self malfunction detecting, doesn't need professional person for maintenance, lower installation andmaintenance cost.
Compact indoor and outdoor design, saves installation space and lowers the installation cost. Parallel connection modular design.
Flexible Piping & Control Solutions
Easier installation, easier maintanance
(Maximum length of piping: 125m)
(Height difference between indoor and outdoor unit: 50m)
(Height difference between indoor units: 30m)
BUS communication
43
1 2
Plug & Play
Flexible Piping
1-drive-more system Flexible 1-drive-more system
1 outdoor unit can drive 16 indoor units
Plug & Play
•
•
•
Inverter A/C System
Compressor parallel connection technology
45 46
This temperature control is
sensitive enough to get the
information about the
temperature in the room and
adjust it automatically.
•
10%135%
Multi-level Energy Adjustment
Compressor Frequency: 30~120Hz
27 levels adjustment
MDV-V
Traditional central Aircon
2 levels adjustment
Power Saving Up to 40%
MDV-VTraditionalcentral Aircon
Inverter compressor and constant compressor are parallel connection in the outdoor unit. In part load
mode only the inverter compressor runs; in full load mode, all the compressors run. So the inverter
compressor will mostly run at the middle frequency range (40-90Hz). Because at the middle frequency
range the inverter compressor has highest efficiency and lowest noise and vibration, the A/C with Compressor
parallel connection technology has higher efficiency and lower noise and vibration than the A/C has only
one inverter compressor. Also it has wide capacity adjusted range (15-110%) than the A/C has only one
inverter compressor, so it has higher SEER.
•
The advanced BUS communication technology (Plug & Play) makes the connection of indoor and outdoor units flexible.
As a modular Multi System, MDV System has excellent expansability.
•
•
The traditional central air
conditioner system can only
supply the same cooling &
heating capacity to all its
indoor units, while the MDV
Inverter Commercial A/C
System can supply exact
cooling & heating capacity to
each individual indoor unit
according to the independent
indoor unit control device.
•
Less floor height
H1>H2
Inverter A/C System
Cooling & Heating
8
10
12
14
16
8+10
10+10
10+12
10+14
10+16
12+16
14+16
16+16
10x2+14
10x2+16
10+12+16
10+14+16
10+16x2
12+16x2
14+16x2
16x3
12x3+14
12x3+16
12x2+14+16
12x2+16x2
10+16x3
12+16x3
14+16x3
16x4
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
13
16
16
16
20
20
20
20
20
20
20
32
32
32
32
32
40
40
40
40
40
50
50
50
50
50
64
64
64
MDV-V252W/CS(N1)
MDV-V280W/CS(N1)
MDV-V335W/CS(N1)
MDV-V400W/CS(N1)
MDV-V450W/CS(N1)
MDV-V532W/CS(N1)
MDV-V560W/CS(N1)
MDV-V615W/CS(N1)
MDV-V680W/CS(N1)
MDV-V730W/CS(N1)
MDV-V785W/CS(N1)
MDV-V850W/CS(N1)
MDV-V900W/CS(N1)
MDV-V960W/CS(N1)
MDV-V1010W/CS(N1)
MDV-V1065W/CS(N1)
MDV-V1130W/CS(N1)
MDV-V1180W/CS(N1)
MDV-V1235W/CS(N1)
MDV-V1300W/CS(N1)
MDV-V1350W/CS(N1)
MDV-V1405W/CS(N1)
MDV-V1455W/CS(N1)
MDV-V1520W/CS(N1)
MDV-V1570W/CS(N1)
MDV-V1630W/CS(N1)
MDV-V1685W/CS(N1)
MDV-V1750W/CS(N1)
MDV-V1800W/CS(N1)
Capacity(HP) Model Combination Indoor unit connected
Outdoor Unit Outdoor Unit
Outdoor Unit
47 48
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
Max Length of pipeMax Height Difference Between indoor units
Between indoor units and outdoor unit
MaxQty per 20'/40'/40'HQ
mmm
Pieces
28.031.5
1-drive-16
45.047.0
40.043.0
396416
33.535.0
1-drive-20
Outdoor Unit
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
Max Length of pipeMax Height Difference Between indoor units
Between indoor units and outdoor unit
MaxQty per 20'/40'/40'HQ
mmm
Pieces
18.021.0
16.018.5
800x1600x620930x1727x760
860056
201217
1-drive-1025/52/52
14.016.5
1-drive-8
500052
8.09.6
220-240,50,1
895x860x3301030x910x430
8190
1-drive-360/122/122
35510
600054
12.014.0
220-240,50,1(380,50,3)
940x1245x3401060x1370x440
135150
1-drive-630/62/62
50820
Cooling & Heating
Outdoor Unit
Remarks: 1.The above specifications are subject to change without prior notice for product improvement. 2.The noise levels given in the table reflect the levels in anechoic chamber.
51 52
Multi-compressor system, no influence occur between each other.
* Be reliable, excellent performance
Available for wire controlling, remote controlling and central controlling in group, it's
convenient for operating.
* Multiform controlling fashion, be convenient for operating
* Be suitable, creates a better lifeMany kinds of indoor untis are available, gives you much more ideas about the
situation, cooling and heating simultaneously, satisfies all your needs.
* Long pipe running, enough vertical fall, free designing stylePipe length between indoor unit and outdoor unit reaches to 70m(10HP system),
the vertical fall between indoor unit and outdoor unit is 20m(10HP system), these
two adventages make the installation position of outdoor unit flexible.
Multi Variable A/C System
Four-cassette type(6kW)Duct type(slim)(6kW)
12kW
Four-cassette type(12.5kW) Duct type(13kW)
High static pressure
Duct type(13kW)
Indoor units
Indoor units
26kW
R407C
R22
R407C
R22
IMDV-M120W/(N2)
12.013.0
220~240,50,1
940x1245x3401058x1377x435
201015
600056
110125
1-drive-230/61/62
25.0(26.0)27.0(28.0)
380,50,3
1290x1540x7501360x1720x820
702020
1000060
295310
1-drive-28/16/16
IMDV-M250(260)W/S(N2)
SystemMatch Configuration
Model
Voltage,Frequence,Phase
Air Flow VolumeNoise Level
Net WxHxDPacking WxHxD
NetGross
kWkW
m3/hdB(A)
mmmm
kgkg
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
Piping Connection
CoolingHeatingElectrical Data
Max Length of pipeMax Height Difference Between indoor units
Between indoor units and outdoor unit
MaxQty per 20'/40'/40'HQ
mmm
Pieces
Indoor UnitIMDV-M60Q4(N2) IMDV-M60T2/-A(N2)Model
Voltage,Frequence,Phase
Air Flow VolumeExternal static pressureNoise Level
Net WxHxD BodyPanel
Packing WxHxD Body Panel
Net Body/PanelGross Body/PanelQty per 20'/40'/40'HQ Indoor
kWkW
mmmmmmmm
kgkg
Pieces
V~,Hz,Ph
Capacity
Performance
Dimension
Weight
CoolingHeatingElectrical Data
m3/hPa
dB(A)
1020
40
6.06.5
840x240x840950x40x950955x260x955
1030x145x1030
220-240,50,1
36/643/11
72/150/168
14003038
1410x240x496
1560x340x570
3640
84/172/199
IMDV-M125Q4(N2) IMDV-M130T2(N2) IMDV-M130T1(N2)
290019647
13.014.0
1200x380x660
1425x480x775
6370
48/96/120
240010046
13.014.0
1350x320x800
1555x370x940
7280
48/100/112
1800
44
12.513.0
840x310x840950x40x950955x325x955
1030x145x1030
220-240,50,1
40/647/11
48/102/122
DC Inverter Multi
Multi System
[ H ] Series
M2OA-18HRDN1
M3OA-27HRDN1
M4OA-27HRDN1
R410A
R410A
R410A
22 Types of Indoor Unit Combinations13 Types of Indoor Unit Combinations
One Unit Two Units
7
9
12
18
7 + 7
7 + 9
7 + 12
7 + 18
9 + 9
9 + 12
9 + 18
12 + 12
12 + 18
38 Types of Indoor Unit Combinations
One Unit Two Units
7
9
12
18
Three Units
7 + 9 + 9
7 + 9 + 12
7 + 12 + 12
9 + 9 + 9
9 + 9 + 127 + 7
7 + 9
7 + 12
7 + 18
9 + 9
9 + 12
9 + 18
12 + 12
12 + 18
7 + 7 + 7
7 + 7 + 9
7 + 7 + 12
7 + 7 + 18
One Unit Two Units
7
9
12
18
7 + 7
7 + 9
7 + 12
7 + 18
9 + 9
9 + 12
9 + 18
12 + 12
12 + 18
Three Units Four Units
7 + 9 + 9
7 + 9 + 12
7 + 9 + 18
7 + 12 + 12
7 + 12 + 18
9 + 9 + 9
9 + 9 + 12
9 + 9 + 18
9 + 12 + 12
9 + 12 + 18
12 + 12 + 12
7 + 7 + 7
7 + 7 + 9
7 + 7 + 12
7 + 7 + 18
7 + 7 + 7 + 7
7 + 7 + 7 + 9
7 + 7 + 7 + 12
7 + 7 + 7 + 18
7 + 7 + 9 + 9
7 + 7 + 9 + 12
7 + 9 + 9 + 9
7 + 9 + 9 + 12
9 + 9 + 9 + 9
9 + 9 + 9 + 12
One outdoor unit can drive 4 free-matched indoor units at most.
54
220-240V~,50Hz
AC Inverter MultiDC Inverter Multi
Cooling & Heating
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.
M2OA-18HRIN1
M3OA-27HRIN1
M4OA-27HRIN1
R410A
R410A
R410A
22 Types of Indoor Unit Combinations13 Types of Indoor Unit Combinations
One Unit Two Units
7
9
12
18
7 + 7
7 + 9
7 + 12
7 + 18
9 + 9
9 + 12
9 + 18
12 + 12
12 + 18
38 Types of Indoor Unit Combinations
One Unit Two Units
7
9
12
18
Three Units
7 + 9 + 9
7 + 9 + 12
7 + 12 + 12
9 + 9 + 9
9 + 9 + 127 + 7
7 + 9
7 + 12
7 + 18
9 + 9
9 + 12
9 + 18
12 + 12
12 + 18
7 + 7 + 7
7 + 7 + 9
7 + 7 + 12
7 + 7 + 18
One Unit Two Units
7
9
12
18
7 + 7
7 + 9
7 + 12
7 + 18
9 + 9
9 + 12
9 + 18
12 + 12
12 + 18
Three Units Four Units
7 + 9 + 9
7 + 9 + 12
7 + 9 + 18
7 + 12 + 12
7 + 12 + 18
9 + 9 + 9
9 + 9 + 12
9 + 9 + 18
9 + 12 + 12
9 + 12 + 18
12 + 12 + 12
7 + 7 + 7
7 + 7 + 9
7 + 7 + 12
7 + 7 + 18
7 + 7 + 7 + 7
7 + 7 + 7 + 9
7 + 7 + 7 + 12
7 + 7 + 7 + 18
7 + 7 + 9 + 9
7 + 7 + 9 + 12
7 + 9 + 9 + 9
7 + 9 + 9 + 12
9 + 9 + 9 + 9
9 + 9 + 9 + 12
One outdoor unit can drive 4 free-matched indoor units at most.
55 56
220-240V~,50Hz 220-240V~,50Hz
Indoor unit
52032
550
6.35/ 9.53 6.35/ 12.7
Cooling/Heating
Model IMSHI-07HRIN1 IMSHI-09HRIN1 IMSHI-12HRIN1 IMST2I-07HRIN1 IMST2I-09HRIN1
Dimension (WxHxD) BodyPanel
Packing (WxHxD) BodyPanel
Net/Gross Weight BodyPanel
Air flow volumeIndoor noise levelLiquid side/Gas side
CapacityBtu/h
mmmmmmmm
kgkg
m3/hdB(A)
mm
7000/9000
750x250x205
830x336x285
8/10
50030
9000/11000 12000/13500Performance
815x280x215
915x360x290
10/12
60033
6.35/ 9.53
7000/9000
955x210x385
1114x277x469
15/19
48034
9000/11000
Outdoor unit
W/WW/Wmmmm
kgm3/hdB(A)
EER-Energy ClassCOP-Energy ClassDimension (WxHxD)Packing (WxHxD)Net/Gross WeightOutdoor air flowOutdoor noise level
Model IMST2I-12HRIN1 IMST2I-18HRIN1 IMSQ4I-07HRIN1 IMSQ4I-09HRIN1 IMSQ4I-12HRIN1 IMSQ4I-18HRIN1Capacity
Btu/h 12000/15000
955x210x385
1114x277x469
15/19
58035
18000/20500 7000/90000Performance
580x254x580650x30x650750x340x750715x115x715
21/303/555032
12000/15000 18000/20500
1301x210x385
1459x277x469
18/22
66040
Dimension (WxHxD) BodyPanel
Packing (WxHxD) BodyPanel
Net/Gross Weight BodyPanel
Air flow volumeIndoor noise levelLiquid side/Gas side
mmmmmmmm
kgkg
m3/hdB(A)
mm
9000/11000
68035
86040
60033
AC Inverter Multi EcoAC Inverter Multi
Cooling & Heating
1-Compressor Triple Split TypeOne inverter compressor drives three
indoor units.
Outdoor Unit Indoor Units
COMP
AA2
A1
A3
1-Compressor Dual Split TypeOne inverter compressor drives two
indoor units.
Outdoor Unit Indoor Units
COMP
AA2
A1
M2OA-18HRIN2
M3OA-27HRIN2
R407C
R407C
22 Types of Indoor Unit Combinations
13 Types of Indoor Unit Combinations
One Unit Two Units
7
9
12
18
7 + 7
7 + 9
7 + 12
7 + 18
9 + 9
9 + 12
9 + 18
12 + 12
12 + 18
One Unit Two Units
7
9
12
18
Three Units
7 + 9 + 9
7 + 9 + 12
7 + 12 + 12
9 + 9 + 9
9 + 9 + 127 + 7
7 + 9
7 + 12
7 + 18
9 + 9
9 + 12
9 + 18
12 + 12
12 + 18
7 + 7 + 7
7 + 7 + 9
7 + 7 + 12
7 + 7 + 18
57 58
One outdoor unit can drive 3 free-matched indoor units at most.Outdoor unit
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.
W/WW/Wmmmm
kgm3/hdB(A)
EER-Energy ClassCOP-Energy ClassDimension (WxHxD)Packing (WxHxD)Net/Gross WeightOutdoor air flowOutdoor noise level
Model IMSHI-07HRIN1 IMSHI-09HRIN1 IMSHI-12HRIN1 IMST2I-07HRIN1 IMST2I-09HRIN1
Dimension (WxHxD) BodyPanel
Packing (WxHxD) BodyPanel
Net/Gross Weight BodyPanel
Air flow volumeIndoor noise levelLiquid side/Gas side
CapacityBtu/h
mmmmmmmm
kgkg
m3/hdB(A)
mm
7000/9000
750x250x205
830x336x285
8/10
50030
9000/11000 12000/13500Performance
815x280x215
915x360x290
10/12
60033
6.35/ 9.53
7000/9000
955x210x385
1114x277x469
15/19
48034
9000/11000
6.35/ 12.7
60033
86040
6.35/ 12.7
Cooling/Heating
Model IMST2I-12HRIN1 IMST2I-18HRIN1 IMSQ4I-07HRIN1 IMSQ4I-09HRIN1 IMSQ4I-12HRIN1 IMSQ4I-18HRIN1Capacity
Btu/h 12000/15000
955x210x385
1114x277x469
15/19
58035
18000/20500 9000/11000Performance
12000/15000 18000/20500
1301x210x385
1459x277x469
18/22
66040
Dimension (WxHxD) BodyPanel
Packing (WxHxD) BodyPanel
Net/Gross Weight BodyPanel
Air flow volumeIndoor noise levelLiquid side/Gas side
mmmmmmmm
kgkg
m3/hdB(A)
mm 6.35/ 9.53
7000/9000
580x254x580650x30x650750x340x750715x115x715
21/303/550032
68035
Multi SeriesAC Inverter Multi Eco
Cooling & Heating
Outdoor unit
W/WW/Wmmmm
kgm3/hdB(A)
EER-Energy ClassCOP-Energy ClassDimension (WxHxD)Packing (WxHxD)Net/Gross WeightOutdoor air flowOutdoor noise level
Performance
Power Input CoolingHeating
Operating Current CoolingHeating
Cooling
Heating
Btu/hkW
Btu/hkW
kWkW
AA
Capacity
Electrical Data
Model
Voltage,Frequency,Phase V~,Hz,PhPower
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.
EERCOPDimension (WxHxD)Packing (WxHxD)Net/Gross WeightOutdoor air flowOutdoor noise level
9000+12000/10000+140002.6+3.5/2.9+4.1
3.073.52
79/83
9000x2/10000x22.6x2/2.9x2
220-240, 50, 1840x2/840x24.0x2/4.0x2
9000x3/10000x32.6x3/2.9x3
3.063.48
860x830x330983x915x425
90/94290058
9000x2+12000/10000x2+140002.6x2+3.5/2.9x2+4.1
3.103.45
895x655x3451050x720x470
73/77200055
3.013.47
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.
EERCOPDimension (WxHxD)Packing (WxHxD)Net/Gross WeightOutdoor air flowOutdoor noise level
9000+12000/10000+130002.6+3.5/2.9+3.8
2.853.27
79/83
9000x2/10000x22.6x2/2.9x2
220-240, 50, 1920x2/900x24.5x2/4.5x2
9000x3/10000x32.6x3/2.9x3
2.843.22
860x830x330983x915x425
90/94290058
9000x2+12000/10000x2+130002.6x2+3.5/2.9x2+3.8
2.833.22
895x655x3451050x720x470
73/77200055
2.853.25
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.
920+1220/900+11505.0+6.0/5.0+6.0
1750+1000/1700+10008.6+5.4/8.4+5.4
1850+1200/1800+11509.0+6.2/8.9+5.9
Indoor unit
68058035
6.35/ 9.53 6.35/ 9.53
Cooling/Heating
Model MSGI-09HRIMSGI-09HR IMSGI-12HR IMST2I-09HR IMST2I-12HR IMSQ4I-09HR IMSQ4I-12HR
Dimension (WxHxD) BodyPanel
Packing (WxHxD) BodyPanel
Net/Gross Weight BodyPanel
Air flow volumeIndoor noise levelLiquid side/Gas side
CapacityBtu/h
mmmmmmmm
kgkg
m3/hdB(A)
mm
9000/10000
750x250x188
830x336x280
8.5/10.5
52030
12000/13000
815x280x195
915x360x275
10.5/13.5
56031
9000/11000Performance
955x210x385
1114x277x469
15/19
55034
6.35/ 12.7
12000/15000 12000/150009000/11000
580x254x580650x30x650750x340x750715x115x715
21/303/5600
6.35/ 12.7 6.35/ 9.53 6.35/ 12.7
Outdoor unit
Remarks: 1.The above design and specifications are subject to change without prior notice for product improvement. 2.The values given in the table for the noise level reflect the levels in anechoic chamber.
Voltage,Frequency,PhasePower Input Cooling/HeatingOperating Current Cooling/Heating
IM2OA-18HR IM2OA-21HR IM3OA-27HR IM3OA-30HRModel
Cooling/Heating Btu/hkW
V~,Hz,PhWA
Capacity
Electrical Data
PerformanceBtu/W.h, W/W
W/Wmmmm
kgm3/hdB(A)
EERCOPDimension (WxHxD)Packing (WxHxD)Net/Gross WeightOutdoor air flowOutdoor noise level
9000+12000/10000+130002.6+3.5/2.9+3.8
9.81, 2.853.27
79/83
9000x2/10000x22.6x2/2.9x2
220-240, 50, 1920x2/900x24.5x2/4.5x2
9000x3/10000x32.6x3/2.9x3
9.82, 2.843.22
860x830x330983x915x425
90/94290058
9000x2+12000/10000x2+130002.6x2+3.5/2.9x2+3.8
9.78, 2.833.22
895x655x3451050x720x470
73/77200055
9.84, 2.853.25
920+1220/900+11505.0+6.0/5.0+6.0
1750+1000/1700+10008.6+5.4/8.4+5.4
1850+1200/1800+11509.0+6.2/8.9+5.9
Heating Water System
[ R ] SeriesBased on reverse Carnot cycle principle, heating water system is one of the most advanced water heater
with the highest COP. Heating water system generally consists of compressor, evaporator, expansion valve,
strainer, accumulator tank, condenser, water tank.
Overview of heating water system
17.5kW 35kW
Compressor
Heat exchanger for air
Expansion Valve
Heat exchanger for water
Cool water
Water tank
Low temp.
High temperature Hot water
Hot waterAir inlet
The sketch of system connection
9.0kW7kW
Heating Water System
64
Integrated design of main unit and
tank makes it very conveniently using
only by connecting the water inlet
and outlet pipes.
Integrative
Integrative
R407C R22
Heating Water System
Installation sketch for single unit
Pipe choice
valvevalvevalvevalvevalvevalve
valvevalvevalvevalvevalvevalve
Heat p
ump
water heater
Heat p
ump
water heater
Heat p
ump
water heater
Heat p
ump
water heater
Heat p
ump
water heater
Heat p
ump
water heater
ON/OFF
Water tank
Drain valve
Pipe union
Pressure meter
Water pump Cutoff valve Water supply
Heat p
ump
water heater
Filter
To user
Heating water system is environmentally friendly and low energy consuming.
Environmental Protection
Less additional operation charge; No need for transportation and storage of
fuel; simple maintenance and reparation.
COP up to 4.0.
Economical
Heating water system does not need storage of fuel and fuel pipe, therefore,
it is free of fuel leakage, fire and explosion.
The unit has multi-protection functions: high-pressure protection, low-pressure
protection, overflow and overload protection for compressor, startup delay,
water switch, water temperature overhigh protection and water level protection
of water tank.
Safety
Automatic intelligent controlling system defrosts automatically in cold winter.
Outdoor installation; no special equipment room needed.
Convenience
Famous brand compressor and plate heat exchanger equipped.
Within the temperature range from -10 to 400C, the heating water system can
work all year around, and perform well against bad weather.
Widely applicable
•
•
•
•
•
•
•
•
•
•
Number of unit (set)
Pipe diameter (inch) 12
141-~1-1
411~1- 1-~212
1~3 4~6 7~9 10~12 13~16
2~3 3~4
Installation sketch for multi units
65 66
Accessories
Heating Water System
Model
Heating capacity
Rated power
Rated current
Hot water volume
Max power
Max current
380V 3N ~ 50HZ
kW
kW
A
m3/h
kW
A
Specification, power supply
Controlling method
Compressor (power x quantity)
Refrigerant
Refrigerant charge
Specification of
water system
MGH-F35W/S
35
9.0
16.6
1.0
11.8
20.2
MGH-F17.5W/S
17.5
4.5
8.6
0.5
5.8
9.8
Manual,Auto and failure alarm
R22/R407C
4.25kW x 2 4.25kW x 1
2300g x 2 2200g x 1
Outlet water temp
Heat exchanger(water side)
Diameter,water inlet pipe
Diameter,water outlet pipe
Max compression resistance
Type
Motor power
Type of air outlet
Length
Width
Height
kg
dB(A)
60 (default)
DN25
DN25
1.0Mpa
Heat exchanger
(gas side)
Demension
Weight
Noise level
250W x 2
Vertical air discharge
1290mm
750mm
1540mm
290
58
150W x 2
Side air discharge
940mm
340mm
1245mm
135
54
MGH-F9W
9.0
2.3
11.0
0.26
3.1
14.8
2.2kW x 1
1300g x 1
220V 1N ~ 50HZ
stainless steel plate heat exchanger
innergroove copper pipe,hydrophilic aluminum coil
DN20
DN20
1.0Mpa
DN15
DN15
1.0Mpa
125W
Vertical air discharge
555mm
555mm
840mm
77
52
MGH-F7W
7.0
2.0
10.0
0.16
2.3
14.0
1.9kW x 1
1000g x 1
DN15
DN15
0.8Mpa
100W
Side air discharge
900mm
530mm
1200mm
70
50
tube-tube heat exchanger
Specification
67
heatexchanger
supply fanexhaust fan
exhaust air
outdoor air intake fresh supply air
indoor return air
Adopt centrifugal fan with lower power consumption and longer air supply distance;Easy control, operation friendly;Compact design, easy installation & maintenance;Optional sprayer to increase unit heat-exchanging efficiency;Can be controlled together with other fresh-air units.
High Quality Steel Board,Static Electricity coating,Heat preservation Material
Nylon Strainer
XFHQ-4DZ-A
400
55
68
52
69
61
30x2
0.35x2
820
1020
270
50
45
XFHQ-5DZ-A
500
150
66
50
66
58
90x2
0.6x2
1350
820
360
76
52
XFHQ-6DZ-A
600
150
66
50
66
58
90x2
0.6x2
1350
820
360
76
52
XFHQ-8DZ-A
800
150
65
52
65
56
150x2
1x2
1350
820
420
82
54
XFHQ-10DZ-A
1000
170
70
54
70
62
200x2
1x2
1350
1020
420
102
56
Model
Air Volume (m /h)Static Pressure (Pa)
Cooling
Heating
temp. efficiency(%)
enthalpy efficiecy(%)
temp. efficiency(%)
enthalpy efficiecy(%)
Power supply
Motor
type
power (W)
current (A)
Fan Motor type
Dimension
length (mm)
width (mm)
height (mm)
Strainer
Structure
Weight (kg)
Single Phase Asynchronous Motor
220V~50Hz
Nylon Strainer
High Quality Steel Board,Static Electricity coating,Heat preservation Material
3
Noise Level dB (A)
centrifugal, direct transmission,three speed abailable
Specification
Fresh-air and exhaust air are crossed through the heat exchanger.Temperature exchange were happened in the heat recovery ventilator.Fresh-air can be got a great deal of energy from exhaust air.
Energy saving
Adopt high quality heat-exchange core.
Small air resistance;
High efficiency
Add sound absorption material,quiet operation.
Low noise
Can be controlled together with other indoor
units by controller.
Flexible multi control ways
Heat Recovery Ventilator (HRV)
7069
SDH-2-A
SDH-3-A
SDH-4-A
SDH-5-A
SDH-6-A
SDH-7/S-A
SDH-8/S-A
SDH-9/S-A
SDH-10/S-A
SDH-12/S-A
SDH-15/S-A
SDH-20/S-A
Modeltotal length
(mm)
220/380
220/380
220/380
220/380
220/380
380
380
380
380
380
380
380
2kW
3kW
4kW
5kW
6kW
7kW
8kW
9kW
10kW
12kW
15kW
20kW
Dimension of cylinder water inlet & outletVoltage
(V)Power(kw)
350
350
400
400
450
450
410
410
510
510
560
560
*158mm 1.25''
*190mm 1.5''
Features
Auxiliary Electric Heater
A
B C D
E
C
D
E
Features
SDS-15/S-A
SDS-18/S-A
SDS-27/S-A
SDS-30/S-A
SDS-45/S-A
SDS-54/S-A
SDS-60/S-A
SDS-72/S-A
SDS-75/S-A
SDS-90/S-A
SDS-100/S-A
SDS-120/S-A
SDS-144/S-A
SDS-150/S-A
SDS-175/S-A
SDS-180/S-A
SDS-200/S-A
Dimension(mm)
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
380V
15KW
18KW
27KW
30KW
45KW
54KW
60KW
72KW
75KW
90KW
100KW
120KW
144KW
150KW
175KW
180KW
200KW
A
960
960
1260
1260
1160
1360
1360
1200
1200
1360
1520
1660
1960
1960
1660
1660
1960
B
350
350
350
350
400
450
450
480
480
530
530
600
600
600
650
650
650
C
280
280
280
280
335
390
390
390
390
440
440
492
540
540
598
598
598
D
159
159
203
203
219
245
245
273
273
325
325
426
426
426
480
480
480
E
130
130
180
180
180
220
220
240
240
240
240
240
240
240
280
280
280
Model Voltage Power
71 72
cover
water outlet
case
water-proof cover water inlet
electric heater inner layer insulation layer
wire hole fix holedrain valve
temp. protector
high efficiency heater tube, uniform heating;
10bar hydraulic test, high safety;
easy for service and maintenance;
customize for special requirements.
•
•
•
•
SDS seriesSDH series
Adopts stainless steel, filling with the high-quality heat-
resistance material between outer shell and interior also
have strong anticorrosive capability.
Adopts the famous-brand temperature controller to prevent
electric device from damaging.
Uniform heating and high efficiency.
•
•
•
RESET BUTTON
Reset current unit to the default setting.
FAN SPEED BUTTON
Adjust fan speed.
MODE BUTTON
Choose the mode.SET BUTTON
Enter into the setting screen.
QUERY BUTTON
Check the running status of the A/C.
SWING BUTTON
With or without swing.
OPERATION INDICATOR
Lights when the unit is in operation.
ON/OFF BUTTON
Start or stop operation.
Central Controller
PREVIOUS OR NEXT BUTTON
OK BUTTON
Confirm the operation.
LOCK BUTTON
Lock or unlock current A/C status.
In query or set mode, Transfer between previous and next unit.
DATAS OR PAGES ADJUST BUTTON
Adjust the datas or pages.
TIMER BUTTON
Set the current time and off time.
73 74
Controller
Description Picture Model Function
Wire Controller(Optional)
suitable for MDV systemKJR-01B/dP(T)
Remote Controller(Standard)
suitable for MDV systemR51, R05/BG
suitable for MDV systemKJR-10B/dP(T)
Contro l 64 indoor units s imu l taneous ly at most (suitable for MDV system)
CCM01Central Control Monitor
(Optional)
Control 32 outdoor units s imu l taneous ly at most (suitable for MDV system)
CCM10Central Control Monitor
(Optional)
Suitable for Intelligent built-in manager system
Touch Controller(Optional) TCM01
ON/OFF BUTTON
Start or stop operation.
RESET BUTTON
Reset all the setting and get in to the condition of beginning.
TIMER BUTTON
Timer setting.TEMP. BUTTON
Preset temperature.
SWING BUTTON
With or without swing.
LOCK BUTTON
Lock or unlock all current setting.
FAN SPEED BUTTON
Choose fan speed.
MODE BUTTON
Choose the mode.
OK BUTTON
Confirm the operation
AUXILIARY HEATER BUTTON
Start or stop the electrical auxiliary heater
FOLLOW ME BUTTON ECONOMY BUTTON
Start or stop economical mode
Adjust the action of indoor unit according to the Temp. sensor inside the wire controller
Wire Controller
Wire Controller(Optional)
Distributor
BY51N1 BY101N1
BY102A BY103A
BY104 BY105
MDV-DY01 MDV-DY02
The dimension of Y-shape three-way pipe.
The connecting point can be freely adjusted to meet different pipes.
Adoption of international standard measurement assures easy replacement.