Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members For helpful discussions Outline Layout Basics and history First results during scrubbing run Conclusion and outlook ECM 08 Nov 2008 CERN
27

Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

Dec 24, 2015

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

Microwave diagnostics for electron cloud detection on the SPS

F. Caspers, E. Mahner, T. KroyerB. Henrist, J.M. Jimenez

Thanks to the SPSU study team membersFor helpful discussions

Outline

Layout Basics and history First results during scrubbing run

Conclusion and outlook

ECM 08 Nov 2008 CERN

Page 2: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

2Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, JimenezF. Caspers, E. Mahner, T. Kroyer

Basic layout for microwave transmission setup (SPS 2008)

Principle idea:“When electromagnetic waves are

transmittedthrough a not too dense plasma, theyexperience a phase shift and possibly a

smallattenuation”

Antenna1 Antenna3

14.4 m 33.1 m

Antenna2 (excitation)

dipolequad

F. Caspers, T. Kroyer

2008 is similar to the 2004 setup

Page 3: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

3Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Some basics and history (1)

Page 4: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

4Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Some basics and history (1a)This general expression for the phase shift in a low density plasma filled waveguide could suggest that it would be ideal to work at or very close to waveguide cutoff…Well in the end we are interestested in a good signal to noise RATIO and if we have too much attenuation when working close to cutoff , it does not help a lot.Also we must keep in mind that we dont like steep slopes in the HTf (hardware transfer function) in order to avoid HTF related AM/PM conversion in other words the upper and the lower modulation sideband should pass with the same attenuation otherwise the difference between upper and lower sideband would look like a phasemodulation.Thus avoid steep slopes !

Page 5: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

5Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Some basics and history (2)

Page 6: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

6Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Some basics and history (3)

Page 7: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

7Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Some basics and history (4)

Page 8: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

8Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Some basics and history (5)

Page 9: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

9Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Some basics and history (6)

The presently used setup in BA5 is rather similar, except that we have dedicated button like PU‘s and kickers with a circulator after the hybrid and rather narrow-band filters (40 MHz) with steep slopes.

The filters are centered at 2.5 GHz. We used this time as receiver a conventional spectrum analyzer and a vector spectrum analyzer.

Page 10: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

10Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Preliminary measurement results in 2008 - scrubbing run (1)

SPS super-cycle 17656

Display from a conventional spectrum analzyer.

The phase modulation is in the small peaks, which are +/- 44 kHz away from the center.

The beam induced signal are the two bigger peaks next to the center line.

Page 11: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

11Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Preliminary measurement results in 2008 - scrubbing run (2)

Display from a conventional spectrum analzyer.

The phase modulation is in the small peaks, which are +/- 44 kHz away from the center.

The beam induced signal are the two bigger peaks next to the center line.

In this display one can see the true width of the carrier, the modulation sideband and the beam signals.

SPS super-cycle 17651

Page 12: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

12Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Preliminary measurement results in 2008 - scrubbing run (3)

SPS super-cycle 17568-69

Time axis is from top to bottom, intensity is color coded. CW signal on

Page 13: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

13Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Preliminary measurement results in 2008 - scrubbing run (4)

SPS super-cycle 17585-87

CW signal off-on-off-on

The VSA has only 80 dB SFD (spurious free dynamic range) due to ADC limitations!

Page 14: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

14Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Preliminary measurement results in 2008 - scrubbing run (5)

SPS super-cycle 17606-08

Shift of CW frequency

Page 15: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

15Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Preliminary measurement results in 2008 - scrubbing run (6)

SPS super-cycle 17601-03

Higher harmonics of the modulation sidebands since the modulation is rather rectangular than sinewave

Page 16: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

16Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Preliminary measurement results in 2008 - scrubbing run (7)

SPS super-cycle 17552Expanded view of one modulation sideband vs time.

Page 17: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

17Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Preliminary measurement results in 2008 - scrubbing run (8)

SPS super-cycle 17641Intensity of the modulation sideband vs time in logarithmic scale

Page 18: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

18Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Preliminary measurement results in 2008 - scrubbing run (9)

SPS super-cycle 17650Intensity of the modulation sideband vs time in linear scale

Page 19: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

19Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Preliminary measurement results in 2008 –AM contamination (1)

SPS super-cycle 21196, July 9th 2008

How about AM contamination?

Are we really sure that what we see on the green trace (upper half) is pure FM or PM

At least in this case its pure AM since the demodulation function of the VSA tells us that there is NO FM or PM signal where we would expect it.(lower trace)

Page 20: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

20Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Preliminary measurement results in 2008 –AM contamination (2)

SPS super-cycle 21200, July 9th 2008

Here one can see a small assymetry in height of the modulation lines in the conventional SPA display which is ALWAYS a hint for superposition of AM and FM or PMAND we also see a very small FM –PM Linie in the lower half of the display where we expect it.

Page 21: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

21Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Preliminary measurement results in 2008 –AM contamination (3)

SPS super-cycle 17024, July 7th 2008

Another exampleUpper half:Conventional spectrumLower halfPM demodulation

This shot was taken after acceleration at flattop where usually we observed the strongest PM signals

2 batches

Page 22: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

22Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Preliminary measurement results in 2008 –AM contamination (4)

SPS super-cycle 16972, July 7th 2008

Here we have in the upper half the conventional spectrum and in the lower half the PM demodulated partObviously we cannot see anything during accerlation and a quantitative evaluation from this colour coded plot is not really possible.

Page 23: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

23Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

LHC beam in SPS, 25 ns bunch spacing, 72 bunches, 1 batch

Preliminary measurement results in 2008 - scrubbing run (10)

PS-type shielded button pickup signals

Yellow trace stripline in stainless steel chamber #1Blue trace pickup in chamber #1 containing enamel clearing electrodeMagenta trace pickup in stainless steel chamber #2 w/o enamel, for referenceNote, that there is some (unexpected) low frequency ringing (EMI) in the blue and magenta traceWe will try to understand its origin and get it removed in the future

Note that depite EMI contamination one can clearly see (light blue trace) the buildup of the e-cloud related current over the duration of the batch

Page 24: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

24Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Conclusion and Outlook

The intermodulation problem observed in 2003 (experiments in BA2) has been considerably reduced using a proper RF setup with highly selective filters at the frontend, both, for excitation and on the pickup side. However the application of the phase demodulation function (using a vector spectrum analyzer) is strongly recommended for the elimination of residual AM contamination due to faint saturation effects [gain compression] (more than 50 dB below the carrier) caused by beam induced signals.

First electron cloud transmission experiments performed during the 2008 SPS scrubbing run in June have shown very promising results in BA5. The presence of electron clouds was identified simultaneously with button pickups.

Microwave transmission over a full LHC arc at cryogenic temperature has been already successfully demonstrated around 7 GHz. The technique discussed here can be directly applied for integral electron cloud diagnostics over a full arc in the LHC. For this purpose the installed in situ reflectometer couplers at the end of each arc could be used.

Many thanks to Christian Carli for lending us the real-time spectrum analyzer and contributing during data taking.

Page 25: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

25Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Conclusion and Outlook (additional comments July 14th)

As for potential AM/PM conversion due to steep slopes in the HTF (hardware transfer function) one can test the hardware transmission with some know  AM level on the generator (and of course known spurious PM) and check at the downstream end of the transmission for changes (in particular additional PM or FM).

For the present case we see from the data shown (well, not all shown this morning) that we had up to 20 dB high pure AM sidebands and no PM indication.

For further reduction of intermodulation risk via beam induced signals the passive front end filter BW (both for the driver and pickup amplifiers) can be reduced to say 2x frev. (here we had 40 MHz with frev in the SPS = 43 kHz).

If additional dynamic range is required the carrier can be suppressed with a high Q passive element notch filter before the received signal is going into the first PU amplifier.

Instead of using the VSA (vector spectrum analzyer) one could also apply a VNA (vector network analyzer) which has a suffiently large IF bandwidth (at least 100 KHz for the SPS) and operate it in the CW FFT mode (may require the use of macros).There might be a higher instantaneous dynamic range with the VNA as compared to the VSA (80 dB limited by the ADCs)

Page 26: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

26Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Related recent results from other labs (1)

Page 27: Microwave diagnostics for electron cloud detection on the SPS F. Caspers, E. Mahner, T. Kroyer B. Henrist, J.M. Jimenez Thanks to the SPSU study team members.

27Nov. 20th 2008

Microwave diagnostics in the SPS ECM 2008 Caspers, Mahner, Kroyer, Henrist, Jimenez

Related recent results from other labs (2) [ILCDR July2008]