Micrologic E Control unit for Compact NS630b to NS3200 and Masterpact NT/NW circuit breakers The smart view to energy efficiency
28

Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

May 01, 2018

Download

Documents

haduong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Micrologic E

Control unit for Compact NS630b to NS3200 and Masterpact NT/NW circuit breakers

The smart view to energy efficiency

Page 2: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 2Power Micrologic E January 2011

Agenda

�The need for accurate energy information

�Micrologic E: Energy efficiency, now within your reach

�Smart: The intelligent way to put energy metering where you need it

�Safe: Protection, communications and metering, reliably in one device

�Simple: Connect energy information to everyone that needs it

�Next steps toward energy efficiency

Page 3: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 3Power Micrologic E January 2011

Buildings can achieve up to 30% energy savings with an Active Energy Management program that includes an energy metering system.

Page 4: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 4Power Micrologic E January 2011

The need for energy information

�Energy costs are increasing

�More stringent greenhouse gas emissions regulations

�Need to reduce energy consumption

> Reveal where, when, how much energyis consumed

> Discover opportunities to improve your efficiency

The first step is energy metering:

Page 5: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 5Power Micrologic E January 2011

Introducing Micrologic E�Control unit for circuit breakers:

�Compact NS630b to NS3200�Masterpact NT/NW

� Includes embedded energy metering capability

> Maximize efficiency> Control costs> Meet environmental objectives

& responsibilities

Most affordable way to help:

Page 6: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 6Power Micrologic E January 2011

SmartThe intelligent way to put energy metering where you need it

Page 7: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 7Power Micrologic E January 2011

Smart – the new industry standard

�Micrologic E extends this across Compact NS and Masterpact NT/NW ranges

�Compact NSX circuit breaker was the first to offer cost-effective, embedded energy metering

Page 8: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 8Power Micrologic E January 2011

Smart – the most affordable choice

�You get an energy meter in every breaker

Avoids the costs and panel space of installing a separate power meter with current transformers

Page 9: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 9Power Micrologic E January 2011

Smart – bridging the gap

2.0 A

5.0 A

6.0 A

7.0 A

2.0 E

5.0 E

6.0 E

5.0 P

6.0 P

7.0 P

5.0 H

6.0 H

7.0 H

Current, maximeter

Voltage, PF, power, demand, energy*

Cos-����, frequency, per phase, advanced protection

Harmonics, waveform capture, enhanced alarms

2 (L, I)

5 (L, S, I)

6 (L, S, I, G)

7 (L, S, I, V)

Mea

sure

men

tPr

otec

tion

No Metering A 'ammeter' E 'energy' P 'power' H 'harmonics'

2.0

5.0

6.0

Page 10: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 10Power Micrologic E January 2011

Smart – high value, low cost

�Compared to popular Micrologic A:�Same integrated LCD�Same ease-of-use�Same reliability

> Energy metering> Some additional features of the model P

For only a small incremental cost, Micrologic E also gives you:

Page 11: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 11Power Micrologic E January 2011

Smart – wide range of applications�The energy data from Micrologic E will improve efficiency

by helping you:

�Study consumption patterns�Compare the performance

of different facilities� Isolate where energy

is being wasted�Expose energy costs at

the building, departmentor machine level

�Validate utility billingand verify energy on feeders matches sum of tenant meters

Page 12: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 12Power Micrologic E January 2011

SafeProtection, communications andmetering, reliably in one device

Page 13: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 13Power Micrologic E January 2011

Safe – a unique, reliable architecture

�You must trust your circuit breakers to protect people and equipment

> Protection operates independently of measurement and communication

> All functions are tested and certified together

�This guarantees the quality and reliability of all functions

Micrologic E has a unique architecture:

Page 14: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 14Power Micrologic E January 2011

Safe – a unique, reliable architecture

Sensors &Power Source

Metering

Power supply

Microprocessor

Advanced protection functions

(metering, analyses…)

Protection

ASIC

Current-dependent power supply

Basic protection functions

Air CT

Iron CT

Processing

CommunicationModule

Communications

SeparationOptical

Link

Page 15: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 15Power Micrologic E January 2011

Safe - Automatic Scroll Quick View

�Personnel do not have to touch the front panel to access data

�Automatically advances through all the most relevant measurements

New, innovative display mode

Page 16: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 16Power Micrologic E January 2011

Safe – more features, more flexibility�Two additional features previously only available in models P & H

�Trip History for easy troubleshooting: � Last 10 trips memorized in

non-volatile memory�Viewable through LCD or software� Includes trip cause &

date/timestamp

�Two relay outputs for coordinated control: �M2C type relays,

driven by trip events�Use for management

functions

Page 17: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 17Power Micrologic E January 2011

SimpleConnect energy information toeveryone that needs it

Page 18: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric Power Micrologic E January 2011

Simple – convenient, local data access

�New BCM ULP communication module option

�Connect FDM121 display to Compact or Masterpact circuit breaker

> All Micrologic measurements and histories> Circuit breaker maintenance indicators

High-visibility data access from electrical cabinet front panel:

Page 19: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 19Power Micrologic E January 2011

Simple – a building-wide network

�BCM ULP allows standard plug-and-play connectivity

�Enables remote access to energy data from Micrologic E

�Create a communication network:�Circuit breakers, relays,

power meters, other devices�Web-enabled gateways or RTUs� Laptops and desktop PCs

Page 20: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 20Power Micrologic E January 2011

Simple – data delivered to your desktop

� Information easily accessible to anyone that needs it� Facility and corporate

managers analyze energy efficiency and costs

�Maintenance personnel analyze electrical system reliability and perform remote maintenance and troubleshooting

View data for further analysis using standard web browsersor user-friendly software

Page 21: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 21Power Micrologic E January 2011

Remote Control Utility (RCU)

Free utility for simple data access and circuit breaker control

Page 22: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 22Power Micrologic E January 2011

iRIO RTU or EGX300 gateway

On-board web servers deliver real-time and historical data

Page 23: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 23Power Micrologic E January 2011

PowerLogic ION Enterprise software

Advanced energy and power quality analysis

Page 24: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within
Page 25: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 25Power Micrologic E January 2011

Thinking ahead

�Micrologic E control unit in every circuit breaker is an important first step toward energy efficiency

�Schneider Electric can help you achieve maximum efficiency across your entire building

Delivering up to 30% energy savingsin industrial and commercial buildings

Page 26: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 26Power Micrologic E January 2011

Active Energy Management

� Integrated strategy from Power Plant to Plug

Page 27: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Schneider Electric 27Power Micrologic E January 2011

Ecostruxure architecture

� Intelligent energy management systems that:�Guarantee compatibility between the

management of power, process and machines, IT rooms, buildings, and security

�This ensures systems are simplified, save money and reduce waste

Page 28: Micrologic E - Schneider Electric · Schneider Electric Power Micrologic E January 2011 2 Agenda The need for accurate energy information Micrologic E: Energy efficiency, now within

Make the most of your energy