Top Banner
Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatic Pneumatic E MicroKing Air Control Valves Direct Acting, M5 & 1/8" Port 3-Way: .19 Cv 4-Way: .18 Cv Section E Basic Valve Functions ................................................ 2 MicroKing Series Basic Features ............................... 3 Common Part Numbers 3-Way ..................................................................... 4 4-Way ..................................................................... 5 Model Number Index .................................................. 6 IEM Bar Manifolds ...................................................... 7 Subbase Bar Manifolds .............................................. 8 IEM Sandwich Regulator ............................................ 9 Subbase Manifold Regulator .................................... 10 Technical Information / Kits & Accessories ......... 11-12 Dimensions .......................................................... 13-16 Bold text part numbers are standard. Standard text part numbers may have longer lead times.
16

MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Jan 31, 2018

Download

Documents

truongnhu
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic

E

MicroKingAir Control ValvesDirect Acting, M5 & 1/8" Port3-Way: .19 Cv4-Way: .18 Cv

Section E

Basic Valve Functions ................................................2MicroKing Series Basic Features ...............................3Common Part Numbers

3-Way.....................................................................44-Way.....................................................................5

Model Number Index ..................................................6

IEM Bar Manifolds ...................................................... 7Subbase Bar Manifolds ..............................................8IEM Sandwich Regulator ............................................ 9Subbase Manifold Regulator .................................... 10Technical Information / Kits & Accessories ......... 11-12Dimensions .......................................................... 13-16

Bold text part numbers are standard.Standard text part numbers may have longer lead times.

pneu

air

e

Page 2: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic2

3-Way, 2-Position,Normally Closed

De-energized position – Solenoid #12 de-energized.Pressure at inlet port 1 blocked, outlet port 2 connectedto exhaust port 3.

Energized position – Solenoid #12 energized.Pressure at inlet port 1 is connected to outlet port 2,exhaust port 3 is blocked.

3-Way, 2-Position,Diverter

De-energized position – Solenoid #12 de-energized.Pressure at inlet port 2 connected to outlet port 3.Port 1 is blocked.

Energized position – Solenoid #12 energized.Pressure at inlet port 2 is connected to outlet port 1.Port 3 is blocked.

2-Way, 2-Position,Normally Closed

De-energized position – Solenoid #12 de-energized.Pressure at inlet port 1 blocked, port 2 is connectedto port 3, which is plugged.

Energized position – Solenoid #12 energized.Pressure at inlet port 1 is connected to outlet port 2.Port 3 is blocked.

* Plug port 3.

4-Way, 2-Position

De-energized position – Solenoid #14 de-energized.Pressure at inlet port 1 connected to outlet port 2.Outlet port 4 connected to exhaust port 3.

Energized position – Solenoid #14 energized.Pressure at inlet port 1 is connected to outlet port 4.Outlet port 2 is connected to exhaust port 3.4-Way valve can be used as a 3-Way NC/NO or a 2-Wayvalve by plugging the appropriate ports.

3-Way, 2-Position,Normally Open

De-energized position – Solenoid #12 de-energized.Pressure at inlet port 3 connected to outlet port 2,exhaust port 1 is blocked.

Energized position – Solenoid #12 energized.Pressure at inlet port 3 blocked, outlet port 2 connectedto exhaust port 1.

3-Way, 2-Position,Selector

De-energized position – Solenoid #12 de-energized.Pressure at inlet port 1 is blocked. Pressure at inletport 3 is connected to outlet port 2.

Energized position – Solenoid #12 energized.Pressure at inlet port 1 is connected to outlet port 2.Pressure at port 3 is blocked.

2-Way, 2-Position,Normally Open

De-energized position – Solenoid #12 de-energized.Pressure at inlet port 3 is connected to outlet port 2.Port 1 is blocked.

Energized position – Solenoid #12 energized.Pressure at inlet port 3 is blocked. Port 2 is connectedto port 1, which is plugged.

* Plug port 1.

2

31

#12 #10

2

31

#12 #10

2

31

#12 #10

2

31

#12 #10

2

31

#12 #10

2

31

#12 #10

MicroKing Series ValvesAir Control Valves

Catalog 0600P-7/USA

Basic Valve Function

MicroKing 3-Way Subbase Valve on 3-Port Subbase BarManifold is available as 3-Way NC and 3-Way NO. Whenchoosing either an NC or NO valve, the valve is thesame but the selector gasket is different to give thedesired function.

2 4

1 3

#14 #12

pneu

air

e

Page 3: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic3

E

Pressure Exhaust

Flow Characteristics• MK 3-Way: .19 Cv• MK 4-Way: .18 Cv

Operating Pressure• Vacuum to 120 PSIG

Ports• 1/8" NPT• M5• 1/4 Inch Tube

Mounting• Inline – Universal Function

- NC, NO- Selector, Diverter

• IEM Bar Manifold• Subbase Valve

- NC, NO, Selector• 3-Port Subbase Aluminum Bar Manifold• 4-Port Subbase Aluminum Bar Manifold

Solenoids• Continuous Duty Rated

• 24" Grommet, 15mm 3-Pin DIN 43650C,1/2" Conduit

• 12VDC to 240VAC

Balanced Poppet• Buna-N• Fluorocarbon

Certification / Approval• Approved to be CSA and

CE marked

3-Way Inline ValveShown Energized

Subbase Valve on 3-PortedSubbase Bar Manifold

Shown De-Energized

MicroKing Series ValvesAir Control Valves

Catalog 0600P-7/USA

Basic Valve Features

1 3

2

13

2

2

MicroKing

1 3

42

4-Way Inline ValveShown De-Energized

pneu

air

e

Page 4: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic4

MicroKing Series Valves3-Way, 2-Position Solenoid

Catalog 0600P-7/USA

Common Part Numbers

3-Way Universal Inline

24" Grommet 3-Pin 15mm DIN 43650C 1/2" Conduit / 24" Leads Voltage Port Size

MKH0NBG45A MKH0NB545A MKH0NBH45A 12VDC

MKH0NBG49A MKH0NB549A MKH0NBH49A 24VDC 1/8" NPT

MKH0NBG53A MKH0NB553A MKH0NBH53A 120VAC

MKHFNBG45A MKHFNB545A MKHFNBH45A 12VDC

MKHFNBG49A MKHFNB549A MKHFNBH49A 24VDC

MKHFNBG53A MKHFNB553A MKHFNBH53A 120VAC

Note: All units with non-locking flush override.

3-Way Subbase Mount

24" Grommet 3-Pin 15mm DIN 43650C Voltage Function

MKVVNBG45A MKVVNB545A 12VDCNormally

MKVVNBG49A MKVVNB549A 24VDC Closed

MKVVNBG53A MKVVNB553A 120VAC

MKWVNBG45A MKWVNB545A 12VDCNormally

MKWVNBG49A MKWVNB549A 24VDC Open

MKWVNBG53A MKWVNB553A 120VAC

Note: All units with non-locking flush override. Valve includes mounting bolts & appropriate NC orNO selector gasket.Subbase valves must be used on PSEK & PSFK Bar Manifolds (Page 8).

1/4" TubePort #2

1/8" NPTPort #1 & #3

2

31

#12 #10

Selector

2

31

#12 #10

Normally Open

2

31

#12 #10

Normally Closed

2

31

#12 #10

Diverter

2

31

#12 #10

Normally Open

2

31

#12 #10

Normally Closed

pneu

air

e

Page 5: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic5

E

MicroKing Series Valves4-Way, 2-Position Solenoid

Catalog 0600P-7/USA

Common Part Numbers

4-Way Inline

4-Way Subbase Mount

24" Grommet 3-Pin 15mm DIN 43650C 1/2" Conduit / 24" Leads Voltage Port Size

MKE0NBG45A MKE0NB545A MKE0NBH45A 12VDC

MKE0NBG49A MKE0NB549A MKE0NBH49A 24VDC 1/8" NPT

MKE0NBG53A MKE0NB553A MKE0NBH53A 120VAC

MKEFNBG45A MKEFNB545A MKEFNBH45A 12VDC

MKEFNBG49A MKEFNB549A MKEFNBH49A 24VDC

MKEFNBG53A MKEFNB553A MKEFNBH53A 120VAC

Note: All units with non-locking flush override.

24" Grommet 3-Pin 15mm DIN 43650C Voltage

MKEVNBG45A MKEVNB545A 12VDC

MKEVNBG49A MKEVNB549A 24VDC

MKEVNBG53A MKEVNB553A 120VAC

Note: All units with non-locking flush override. Valve includes mounting bolts and gasket.Subbase valves must be used on PSEK & PSFK Bar Manifolds (Page 8).

1/4" TubePort #2 & #4

1/8" NPTPort #1 & #3

2 4

1 3

#14 #12

2 4

1 3

#14 #12

pneu

air

e

Page 6: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic6

MicroKing Series Valves3-Way & 4-Way, 2-Position Solenoid

Catalog 0600P-7/USA

Model Number Index

Basic Operator / Port Size / Pilot Source / Enclosures / EngineeringSeries Function Thread Type Exhaust Overrides Lead Length Voltage Options Level

MK H 0 N B G 53 – A

EngineeringLevel

A Current

Port Size / Thread Type

3-Way0* 1/8" NPT Inline3 1/4" Tube - Port 1 & 2;

1/8" NPT - Port 3 Inline6 1/4" Tube - Port 2 & 3;

1/8" NPT - Port 1 InlineC* M5 InlineD 1/4" Tube - Port 1, 2 & 3 InlineF* 1/4" Tube - Port 2;

1/8" NPT - Port 1 & 3 InlineV† Subbase Valve Less Base

4-Way0* 1/8" NPT Inline3 1/4" Tube - Port 1, 2 & 4;

1/8" NPT - Port 3 InlineC* M5 Inline

F* 1/4" Tube - Port 2 & 4;1/8" NPT - Port 1 & 3 Inline

V† Subbase Valve Less Base

* Available on IEM Manifold† Not Available with Conduit

Enclosures

Operator / Function

3-Way InlineH Universal 3-Way,

Spring Return

3-Way SubbaseV 3-Way Normally Closed,

Spring ReturnW 3-Way Normally Open,

Spring Return

4-Way Inline / SubbaseE 4-Way Single Solenoid,

Spring Return

Pilot Source /Pilot Exhaust

N Direct Operated

VoltageAC

DC60Hz 50Hz

42 24 2245 1247* 1248* 2449 2453 120 11057 240 220

* Mobile Voltage. NotAvailable for 4-Wayvalves.

Overrides

A No OverrideB Flush -

Non-LockingC* Flush - Locking

* Not available withOperator / Function Eand Voltage Codes 45,47, 48, and 49.

Options

Blank None02 Coil Connection 180° from Port #2V0 Fluorocarbon SealsV2 Fluorocarbon Seals, Coil

Connection 180° from Port #2F0* Flow ControlF2* Flow Control, Coil Connection 180°

from Port #2FV* Flow Control, Fluorocarbon SealsF4* F2 + FV

* Available on 4-Way Valves Only(Operator Function ‘E’)

BOLD OPTIONS ARE STANDARD

Subbase valves with option ‘02’ or ‘V2’ will not mount on SubbaseManifolds with the Regulator Option.

Locking Override Option (Option “C”) not available with Regulator Gauges.

Inline valves with option ‘02’, ‘V2’, ‘F2’ or ‘F4’ will not mount on IEMManifolds with Sandwich Regulators when the valve is configured forNormally Closed function.

MicroKing

Note: OverridesNo Override option is recommended inapplications which require an increasedresistance to moisture. This option alsoincludes a special gasket.

Enclosures / Lead Length

5 15mm 3-Pin DIN 43650CG Grommet / Flying Leads 24"H*† 1/2" Conduit / Flying Leads 24"Q* Grommet / Flying Leads 72"

* Only available with 12VDC, 24VDC &120AC. For other voltages, pleasecontact factory.

† Will not mount on IEM manifolds.

(Revised 2/9/05)

pneu

air

e

Page 7: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic7

E

MicroKing Series ValvesIEM Bar Manifolds

Catalog 0600P-7/USA

Bar Manifold

3-Way & 4-Way IEM, NPT PSMKNXN##NP ## – stations 02 to 25

• IEM Bar Manifold allows for mounting of 3-Way & 4-Way Inline MicroKing Valves. For 4-Way valves, inlet shouldalways be at Port 1.

• Standard Manifold allows mounting of Normally Closed and Normally Open 3-Way Valves simultaneously byrotating valve mounting as shown in picture.

• Manifolds available in all station lengths 2 thru 25.

• Manifold Kit includes o-rings and bolts.

• Ports 1 & 3 are always 1/8" Pipe.

How to Order an Add-A-Fold AssemblyItem Qty Part Number001 1 AAPSMKNXN04NP002 3 MKH0NB549A

- Station 1, 3 - Normally Closed- Station 2 - Normally Open

003 2 PS2130166P*- Station 1, 2

004 1 MKE0NB549A- Station 4

* Regulator Gauges included but not assembled.

When ordering Add-A-Folds, list valves left to right when looking at the Port #3side of the manifold.

Valve Function NC or NO and Regulator / Blank Plate location must bespecified.

2

2

2

Station 1 Station 3Station 2 Station 4

3

1

3

1

4

2

Stations

02•••

25

Type

M IEM

Cylinder Port # ofType Series Pilot Ports Type Stations Options

AA PS M K N X N 04 N P

Model Number

Series

K MicroKing

Cylinder Ports

X IEM Manifold

Port Type

N NPT

Pilot

N Direct

Options

N None

Blank Manifold OnlyAA Manifold with

Valves Mounted

3-Way Valveson Bar Manifold

4-Way Valveson Bar Manifold

3-Way & 4-Way Valveson Bar Manifold

pneu

air

e

Page 8: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic8

Station 1 Station 2 Station 3 Station 4

NO NO NC NC

Catalog 0600P-7/USA

Subbase Bar ManifoldMicroKing Series Valves3-Port & 4-Port, Subbase Bar Manifolds

3-Way, Subbase, NPT PSFKN1N##NP

3-Way, Subbase, 1/4" Tube Port #2 PSFKNBN##NP

## – stations 02 to 25

• 3 & 4-Ported Subbase Bar Manifold uses 3 & 4-Way Subbase mount MicroKing Valves.• Standard Manifold allows mounting of 3-Way Normally Closed and Normally Open Valves simultaneously

by use of selector gaskets.• Bar Manifold Regulator Option is available with Option Code ‘R’.• 3-Way Valve includes selector plate and mounting bolts.

4-Way valve will include sandwich plate and mounting screws.• Ports 1 & 3 are always 1/8" Pipe.

How to Order an Add-A-Fold Assembly

Item Qty Part Number001 1 AAPSFKN1N04RP

002 2 MKWVNB549A - Station 1, 2

003 2 MKVVNB549A - Station 3, 4

004 3 PS2109P - Station 1, 2 & 3

005 1 PS2131166P* - Station 4* Regulator gauges included but not assembled.

When ordering Add-A-Folds, list valves left to right when looking at the Port 2side of the manifold.

Regulator / Cover Plate / Blank Plate location must be specified.

Stations

02•••

25Type

E 3-Way Bottom PortF 3-Way End PortK 4-Way Bottom PortJ 4-Way End Port

Cylinder Port # ofType Series Pilot Ports Type Stations Options

AA PS F K N 1 N 04 N P

Model Number

Cylinder Ports

0 M51 1/8"B 1/4" Tube

Port Type

N NPT

Pilot

N DirectOperated

Options

N NoneR Machined for

Regulator(All Stations)

V Machined forValvetronicConnector

Blank Manifold OnlyAA Manifold with

Valves Mounted

Series

K MicroKing

4-Way, Subbase, NPT PSJKN1N##NP

4-Way, Subbase, 1/4" Tube Port #2 & #4 PSJKNBN##NP

## – stations 02 to 25

Bottom Ports

Side Ports

pneu

air

e

Page 9: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic9

E

1 3

2

MicroKing Series ValvesIEM Sandwich Regulators

Catalog 0600P-7/USA

Accessories

Gauge 3/4" Face (.91" OD) –0-160 PSI ....... PS3451160P

Brass Adapters for Gauge –1/8" to 1/8" Female Coupling ............ 207P-21/8" Male Pipe Nippled 1.5" .... 215PNL-2-151/8" Male to Female Adapter ......... 222P-2-2

1/8" to 1/8" 45° Female Elbow ..... 2201P-2-21/8" to 1/8" 90° Female Elbow ..... 2200P-2-2

IEM Sandwich Regulator• Pressure regulation for individual valves mounted on

IEM Bar Manifold.

• Same Sandwich Regulator used for 3-Way NormallyClosed and Normally Open Valves and 4-Way Valves.

PSI Common Port Common Port Cvwith Gauge * without Gauge

60 PSI PS2130155P PS2130122P.11

125 PSI PS2130166P PS2130133P

* Gauge is 160 PSI.

When mounting Regulators side-by-side or with NormallyOpen valves, gauges must be staggered. Brass adapters arelisted at the bottom of the page.

Regulator without gauge includes 1/8" gauge plug.

Regulator with gauge includes 1/8" gauge plug & gauge(unassembled).

3/2 Normally Closed

4/2

1

2

3

1 3

42

3/2 Normally Openpneu

air

e

Page 10: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic10

Subbase Manifold Regulator• Pressure regulation for individual valves mounted on

3-Port or 4-Port Subbase Bar Manifold.

• Use Manifold with Option Code ‘R’ – all stationsprepared to accept Regulator Kits or Cover Kits.

• Regulator Kits and Cover Kits ordered separately.

PSI Common Port Common Port Cvwith Gauge * without Gauge

60 PSI PS2131155P PS2131122P.11

120 PSI PS2131166P PS2131133P

* Gauge is 160 PSI.

When mounting Regulators side-by-side, gauges must bestaggered. Brass adapters are listed at the bottom of thepage.

Regulator without gauge includes M5 gauge plug.

Regulator with gauge includes M5 gauge plug, 10-32x1/8"swivel fitting & gauge (unassembled).

Regulator Cover Plate ............................................. PS2109P

MicroKing Series ValvesSubbase Manifold Regulators

Catalog 0600P-7/USA

Accessories

3/2 Normally Closed

3/2 Normally Open

Gauge 3/4" Face (.91" OD) –0-160 PSI ....... PS3451160P

Note: Valve with Locking Override Option ‘C’ not available whenRegulator Gauge is used.

1

23

1

23

Brass Adapters for Gauge –#10-32 Male to #10-32 Female Extender (Qty. 10) ................................................ PS2195P#10-32 Male to 1/8" Female Straight Swivel (Qty. 5) .............................................. PS2196P

4/2

2

2 4

4

31

pneu

air

e

Page 11: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic11

E

Catalog 0600P-7/USA

Technical InformationMicroKing Series ValvesSolenoid Data / Kits & Accessories

Average Fill Time (Seconds): With 100 PSIG supply, time required to fill from0-90 PSIG and exhaust from 100 PSIG to 10 PSIG is measured from instant of energizing, orde-energizing solenoid. Times shown are average.

Tested per ANSI / (NFPA) T3.21.8.

Response Time

Code Voltage0 Cu. In. Test Chamber 12 Cu. In. Test Chamber

Fill Exhaust Fill Exhaust49 24VDC .025 .018 .335 .37453 120VAC .021 .029 .309 .389

Note: Voltage Tolerance: +10 / -15%* Mobile voltage applications: +25 / -30%, not available with 4-Way

0

1

1

17.4mm

15mm22 AWG Wire

2.3mmTop of light

Molded 6'Cord Shown

15mm 3-Pin DIN 43650CConnector

ConnectorDescriptionwith 6' (2m) Cord

PS2932BP PS2932JBP UnlightedPS294675BP PS2946J75BP* Light – 12VAC or DCPS294679BP PS2946J79BP* Light – 24VAC or DCPS294683BP PS2946J83BP* Light – 110/120VACPS294687BP N/A Light – 240/230VAC

* LED with surge suppression.Note: Max ø6.5mm cable size required for connector w/o 6' (2m) cord.

Connector Description

1/2" NPTF Conduit – UnlightedPS2998P with 3' (1m) Leads

20 AWG Wire

Note: Rated up to 250VAC or VDC; 6 Amps

Performance InformationElectrical Flow

Voltage Power Holding Cv Chart - Buna-N (Fluorocarbon)Code AC DC Consumption Current Inline Subbase

60Hz 50Hz (W / VA) (Amps) M5 1/8", 1/4" Tube M5 1/8", 1/4" Tube

42 24 22 — 5.4VA .228.15 (.11) .19 (.15) .11 (.11) .15 (.15)

45 — — 12 4.8W .40147* — — 12 4.3W .402

.15 (.11) .15 (.15) .11 (.11) .15 (.15)48* — — 24 4.9W .20449 — — 24 4.9W .20353 120 110 — 5.4VA .045 .15 (.11) .19 (.15) .11 (.11) .15 (.15)57 240 220 — 6.0VA .025

Operating PressureType Minimum Maximum

3 & 4-Way Vac 120 PSIG

Temperature RatingBuna-N: 5°F to 120°F (-15°C to 49°C)Fluorocarbon: 5°F to 140°F (-15°C to 60°C)

Cv tested per ANSI / (NFPA) T3.21.3

Valvetronic 110 System

Connector Description

912171903515mm DIN 43650C with 8mm Snap-inRound Connector, .3 (12") Meter Cable

9121719001Valvetronic 110 Connection Block with3 Meter Cable

Note: Rated up to 24VDC; 4 amp max.IP65 rated when properly installed. 85mm

18.7mm

12.5mm

75mm

15mm DIN 43650C with8mm Snap-in Round

Connector

Valvetronic 110 System

0

1

1

16mm25.4mm

8mm

47mm

12

3

*

* Ground spade offset by0.2mm toward pin 1.

15mm DIN 43650C to 1/2" Conduit

Engineering Data:Conductors: 2 Poles Plus GroundCable Range (Connector Only): 4 to 6mm (0.16 to 0.24 Inch)Contact Spacing: 8mm

pneu

air

e

Page 12: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic12

Catalog 0600P-7/USA

Technical InformationMicroKing Series ValvesKits & Accessories

.59(15mm)

1.38(35mm)

.06(1.5mm)

Type IEM Bar 4-Port Subbase Bar

3-Way PS2190P PS2190P

4-Way PS2190P PS2190P

Kit includes: (2) Screws, (2) Nuts, (2) Clamps

DIN Rail Hardware Kit

DIN RailAM1DE200 6 Foot Rail Length

Regulator Cover PlateType Kit Number

3-Way / 4-Way PS2109P

Kit includes: (1) Cover plate, (2) Screws,( 1) O-ring

Replacement KitsPS2184P IEM Valve/Manifold O-ring Kit (10)PS2187P IEM Valve/Manifold Bolt Kit (10)PS2105P 3-Way Selector Gasket NC

PS2106P 3-Way Selector Gasket NOPS2188P Subbase Valve / Manifold Bolt Kit (10)PS210501P 4-Way Subbase Valve Sandwich Plate Kit (10)

Blanking Plug White Label

Blanking Plugs and Labels(Use with Valvetronic 110)

Model Number Description

9121719003 Blanking Plugs to close unusedconnections (Pack of 10)

9121719004 Labels to insert in grooves on side ofconnection (Pack of 10)

Blanking Plate

DIN Rail

Kit Number

Type IEM Universal IEM SubbaseNPT BSPP “G” Blank Blank

3-Way PS2166P PS2167P PS2169P PS2194P

4-Way PS2166P PS2167P PS2169P PS219401P

Kit includes: (1) Plate, (2) Screws, Gaskets

Universal BlankingPlate

13

DIN Rail Hardware Kit

IEM / SubbaseBlanking Plate

Selector SandwichModel Number Description

PS2144P Selector SandwichKit Includes: (1) Selector Sandwich, (2) Screws,(4) O- rings, (2) 1/8" pipe plugs.

Note:For use with MicroKing 3-Way or 4-Way inline valves. The SelectorSandwich can be used to select a separate supply or separateexhaust for a individual valve which is mounted on an IEM barmanifold.

pneu

air

e

Page 13: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic13

E

1 3

2

2

2

2

3-Way NC

3-Way NO

3-Way NC

3-Way NO

L

M

H

H (Ref.)1/8 Inch Pipe

ED

G

F

N + M x (n) P + M x (n)

C

Q

A

B

K

J

Max. Hex Size (Across Flats)For Inlet / Exhaust Ports = 3/4" (18mm)

n = Number of Stations

MicroKing Series Valves3-Way Inline & IEM Manifold

Catalog 0600P-7/USA

Dimensions

MicroKing IEM Manifold

A B C D E5.99 4.53 3.70 1.48 .74

(152)§ (115) (94) (38) (19)

F G H J K2.68 2.68 .20 3.03 2.13(68) (68) (5) (77) (54)

L M N P Q.83 .81 .42 .82 Ø .26(21) (20,5) (10,8) (20,8) Ø (6.8)

Inches (mm)§ - 3mmWeight

2 Station ............... 2.5 oz (.07 Kg)Each Additional ....... 1 oz (.03 Kg)Regulator w/Gauge4.5 oz (.12 Kg)

JNon-Locking

OverrideK

LockingOverride

3

1

L

H

G (Ref.)E

2

M Dia

N Dia

B

A

F

D

Max. Hex Size (Across Flats)For Inlet / Exhaust Ports = 9/16" (14mm)

C

GROMMET / FLYING LEADS

1/2" CONDUIT

15MM 3-PIN DIN

P

P

R

Q

MicroKing 3-Way Inline

A B C D E.71 .71 1.50 .79 .24(18) (18) (38) (20) (6)

F G H J K.28 .63 1.30 2.60 2.87(7) (16) (33) (66) (73)

L M N P Q.79 .13 .20 1.21 1.06(20) (3.3) (5) (31) (27)

R2.02(51)

Inches (mm)

Weight ...................... 4.5 oz (.12 Kg)

pneu

air

e

Page 14: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic14

MicroKing Series Valves3-Way Subbase Manifold

Catalog 0600P-7/USA

Dimensions

13

3-Way NC

3-Way NC

3-Way NO

3-Way NO

F

G

E

DC

B

A

NO

NO

NC

NC

HE (Ref.)J + H x (n) K + H x (n) Max. Hex Size (Across Flats)

For Inlet / Exhaust Ports = 13/16" (20mm) n = Number of Stations

L

1/8 Inch Pipe

MicroKing 3-Way Subbase

Manifold

A B C D E4.33 2.74 1.57 .79 .20

(110)† (70)‡ (40)§ (20) (5)

F G H J K2.58 1.10 .81 .38 .77(66) (28) (20,5) (9,7) (19,7)

LØ .26

Ø (6.8)

Inches (mm)† ± 5mm‡ ± 3mm§ - 3mm

Weight2 Station ............... 5.0 oz (.14 Kg)Each Additional .... 1.8 oz (.05 Kg)Regulator w/Gauge 3.5 oz (.1 Kg)

Note: Valve options ‘02’ & ‘V2’ - Solenoid Rotated 180° -NOT available with regulator option.

Locking Override Option (Option “C”) not availablewith Regulator Gauges.pneu

air

e

Page 15: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic15

E

1 3

1/8 Inch PipeMax. Hex Size (Across Flats)For Inlet / Exhaust Ports = 3/4" (18mm)

E

DC

F

B

N

A

4

2

4

2

J

KE (Ref.)L + K x (n) M + K x (n)

H

G

n = Number of Stations

4

2

4

2

Selector Sandwich KitPS2144P

MicroKing Series Valves4-Way Inline & IEM Manifold

Catalog 0600P-7/USA

Dimensions

MicroKing 4-Way Inline

A B C D E.71 .71 1.50 .79 .63(18) (18) (38) (20) (16)

F F1 G H J.28 .87 .63 1.30 2.87(7) (22) (16) (33) (73)

K L M N P3.15 .79 .13 3.25 1.21(80) (20) (3.3) (83) (31)

Q R1.06 2.02(27) (51)

Inches (mm)

Weight ...................... 4.5 oz (.12 Kg)

C

JNon-Locking

OverrideK

LockingOverride

34

1

L

H

GE

2

M Dia

N Dia

B

A

F

F1

D

Max. Hex Size (Across Flats)For Inlet / Exhaust Ports = 9/16" (14mm)

GROMMET / FLYING LEADS

1/2" CONDUIT

15MM 3-PIN DIN

P

P

R

Q

MicroKing IEM Manifold

A B C D E3.70 1.48 .74 .20

()§ (94) (38) (19) (5)

F G H J K2.95 3.03 2.13 .83 .81(75) (77) (54) (21) (20,5)

L M N.42 .82 Ø .26

(10,8) (20,8) Ø (6.8)

Inches (mm)§ - 3mmWeight

2 Station ............... 2.5 oz (.07 Kg)Each Additional ....... 1 oz (.03 Kg)Regulator w/Gauge4.5 oz (.12 Kg)

pneu

air

e

Page 16: MicroKing Air Control Valves - SMC Pneumatics U.S.A · PDF fileParker Hannifin Corporation Pneumatic Division Richland, Michigan Pneumatic E MicroKing Air Control Valves Direct Acting,

Parker Hannifin CorporationPneumatic DivisionRichland, Michiganwww.parker.com/pneumatic

Pneumatic16

13

F

G

E

D D1

C

B

A

HE (Ref.)J + H x (n) K + H x (n)

n = Number of Stations

L

1/8 Inch Pipe

With Regulator

With Regulator

With Flow Controls

MicroKing Series Valves4-Way Subbase Manifold

Catalog 0600P-7/USA

Dimensions

MicroKing 4-Way Subbase

Manifold

A B C D D1

4.53 2.87 1.77 .83 .79(115)† (73)‡ (45)§ (21) (20)

E F G H J.19 3.07 1.57 .84 .51(5) (78) (40) (21) (13)

K L M.91 Ø .28 .23(23) Ø (7) (6)

Inches (mm)† ± 5mm‡ ± 3mm§ - 3mm

Weight2 Station ............. 11.7 oz (.33 Kg)Each Additional ....... 4 oz (.12 Kg)Regulator w/Gauge 3.5 oz (.1 Kg)

Note: Valve options ‘02’ & ‘V2’ - Solenoid Rotated 180° -NOT available with regulator option.

Locking Override Option (Option “C”) not availablewith Regulator Gauges.pneu

air

e