Microinverter 4 in 1 unit “The World's First Single-Phase Microinverter”designed for 4 solar panels with dual MPPT, with wide DC input operating voltage range (16-60V) and low start-up voltage (22V only). Hoymiles 4 in 1 microinverter MI-1000/MI-1200/MI-1500 is“The Best Power Density Microinverter”ev- er in the solar industry with extremely light weight - only 3.75kG including integrated DC & AC cables; 3-phase wiring makes it easy to be configured by Hoymiles 4 in 1 microinverter for MW size commer- cial PV power stations (one of the world's biggest microinverter projects configured by Hoymiles microinverter is 3.6MW). MI-1000 / MI-1200 / MI-1500 www.hoymiles.com 2.4GHz Proprietary RF(Nordic) Hoymiles Monitoring System Mechanical Data Ambient temperature range (℃) Dimensions (W X H X D mm) Weight (kG) Enclosure rating Cooling -40~+65 280 X 176 X 33 3.75 (including 2.32m AC cable) Outdoor-IP67 Natural convection - No fans Efficiency CEC peak efficiency CEC weighted efficiency Nominal MPPT efficiency Nighttime power consumption (mW) 96.70% 96.50% 99.80% <50 Output Data (AC) Rated output power (W) Rated output current (A) Nominal output voltage (V) Nominal output voltage range (V) Nominal frequency/range (V) Power factor Total harmonic distortion Maximum units per branch 1000 4.54 / 4.38 / 4.17 220 / 230 / 240 180-275¹ 50/45-55 ¹ or 60/55-65 ¹ >0.99 <3% 5 / 5 / 5 1200 5.45 / 5.22 / 5 220 / 230 / 240 180-275¹ 50/45-55 ¹ or 60/55-65 ¹ >0.99 <3% 4 / 4 / 4 1500 6.82 / 6.52 / 6.25 220 / 230 / 240 180-275¹ 50/45-55 ¹ or 60/55-65 ¹ >0.99 <3% 3 / 3 / 3 Model Input Data (DC) Commonly used module power (W) Peak power MPPT voltage range (V) Start-up voltage (V) Operating voltage range (V) Maximum input voltage (V) Maximum input current (A) Up to 310 / 380 / 470 (single panel) 27~48 / 32~48 / 36~48 22 16~60 60 4*10.5 / 4*10.5 / 4*11.5 MI-1000 / MI-1200 / MI-1500 (4 X 60 cells or 4 X 72 cells) Communication Monitoring Warranty Loading Quantity Container Pallet No. Carton No. Total quantity 1 X 40’GP / 1X 40’HQ 22 756 3780 1 X 20’GP 10 360 1800 Highlights Maximum output power up to 1000/1200/1500W; Adapted to 60 & 72 cells PV panels Peak efficiency 96.70%; CEC weighted efficiency 96.50% Static MPPT efficiency 99.80%; Dynamic MPPT efficiency 99.76% in overcast weather High reliability: NEMA6 (IP67) enclosure ; 6000V surge protection IEC/EN 61000-6-1:2007, IEC/EN 61000-6-2:2005, IEC/EN 61000-6-3:2007+A1:2011, IEC/EN 61000-6-4:2007+A1:2011, IEC/EN 61000-3-2:2014, IEC/EN 61000-3-3:2013 IEC/EN 62109-1:2010, IEC/EN 62109-2:2011 IEC 61727:2004, IEC 62116:2014, IEC 61683:1999, DIN VDE 0126-1-1(VDE V 0126-1-1):2013-08, VFR 2019, EN 50438:2013, ABNT NBR 16149:2013, ABNT NBR 16150:2013, NRS 097-2-1:2017 Edition 2, NBT 32004:2018 Standard Compliance EMC Safety On-Grid Up to 25 years Other Features IC
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Microinverter4 in 1 unit
“The World's First Single-Phase Microinverter”designed for 4 solar panels with dual MPPT, with wide DC input operating voltage range (16-60V) and low start-up voltage (22V only).
Hoymiles 4 in 1 microinverter MI-1000/MI-1200/MI-1500 is“The Best Power Density Microinverter”ev-er in the solar industry with extremely light weight - only 3.75kG including integrated DC & AC cables; 3-phase wiring makes it easy to be configured by Hoymiles 4 in 1 microinverter for MW size commer-cial PV power stations (one of the world's biggest microinverter projects configured by Hoymilesmicroinverter is 3.6MW).
MI-1000 / MI-1200 / MI-1500
www.hoymiles.com
2.4GHz Proprietary RF(Nordic) Hoymiles Monitoring System
1200/15004.35/5.22
230/180-27550/45-55>0.99 <3%4 / 3
Mechanical DataAmbient temperature range (℃)Dimensions (W X H X D mm)Weight (kG)Enclosure ratingCooling
-40~+65280 X 176 X 33
3.75 (including 2.32m AC cable)Outdoor-IP67
Natural convection - No fans
EfficiencyCEC peak efficiencyCEC weighted efficiencyNominal MPPT efficiencyNighttime power consumption (mW)
96.70%96.50%99.80%
<50
Output Data (AC)Rated output power (W)Rated output current (A)Nominal output voltage (V)Nominal output voltage range (V)Nominal frequency/range (V)Power factorTotal harmonic distortionMaximum units per branch
1000 4.54 / 4.38 / 4.17220 / 230 / 240
180-275¹50/45-55 ¹ or 60/55-65 ¹
>0.99 <3%
5 / 5 / 5
1200 5.45 / 5.22 / 5
220 / 230 / 240180-275¹
50/45-55 ¹ or 60/55-65 ¹ >0.99 <3%
4 / 4 / 4
15006.82 / 6.52 / 6.25220 / 230 / 240
180-275¹50/45-55 ¹ or 60/55-65 ¹
>0.99 <3%
3 / 3 / 3
Model
Input Data (DC) Commonly used module power (W)Peak power MPPT voltage range (V)Start-up voltage (V)Operating voltage range (V)Maximum input voltage (V)Maximum input current (A)
Up to 310 / 380 / 470 (single panel)27~48 / 32~48 / 36~48
2216~60
604*10.5 / 4*10.5 / 4*11.5
MI-1000 / MI-1200 / MI-1500(4 X 60 cells or 4 X 72 cells)
IEC 61727:2004, IEC 62116:2014, IEC 61683:1999, DIN VDE 0126-1-1(VDE V 0126-1-1):2013-08, VFR 2019, EN 50438:2013, ABNT NBR 16149:2013, ABNT NBR 16150:2013, NRS 097-2-1:2017 Edition 2, NBT 32004:2018
Standard Compliance
EMC
Safety
On-Grid
Up to 25 years
Other Features
IC
“The World's First Daisy-Chain 2 in 1 Microinverter for Large Scale Commercial Application”is designed for dual solar panels with double MPPT, and wide DC input operating voltage range (16-60V) and low start-up voltage (22V only).
Hoymiles 2 in 1 microinverter MI-600/MI-700/MI-800 is the world's most powerful microinverter solution for dual solar panels with world's leading CEC weighted efficiency 96.50%; with quicker installa-tion and much higher power density compared with single unit, it's also one of the best-selling microin-verters for Hoymiles up to now worldwide.
MI-600 / MI-700 / MI-800
Microinverter2 in 1 unit
www.hoymiles.com
Standard Compliance
Other FeaturesCommunicationMonitoring
2.4GHz Proprietary RF(Nordic)Hoymiles Monitoring System
Mechanical DataAmbient temperature range (℃)Dimensions (W X H X D mm)Weight (kG)Enclosure ratingCooling
-40~+65250 X 170 X 28
3.00 (including 2.32m AC cable)Outdoor-IP67
Natural convection - No fans
EfficiencyCEC peak efficiencyCEC weighted efficiencyNominal MPPT efficiencyNighttime power consumption (mW)
96.70%96.50%99.80%<50
Output Data (AC)Rated output power (W)Rated output current (A)Nominal output voltage (V)Nominal output voltage range (V)Nominal frequency/range (V)Power factorTotal harmonic distortionMaximum units per branch
600 2.73 / 2.61 / 2.5220 / 230 / 240
180~275 ¹50/45-55 ¹ or 60/55-65 ¹
> 0.99 < 3%
8 / 8 / 8
800 3.64 / 3.48 / 3.33220 / 230 / 240
180~275 ¹50/45-55 ¹ or 60/55-65 ¹
> 0.99 < 3%
6 / 6 / 6
Model
Input Data (DC) Commonly used module power (W)Peak power MPPT voltage range (V)Start-up voltage(V)Operating voltage range (V)Maximum input voltage (V)Maximum input current (A)
Up to 380 / 440 / 500 (single panel)29~48 / 33~48 / 34~48
2216~60
602*11.5 / 2*11.5 / 2*12.5
MI-600 / MI-700 / MI-800(2 X 60 cells or 2 X 72 cells)
IEC 61727:2004, IEC 62116:2014, IEC 61683:1999, DIN VDE 0126-1-1(VDE V 0126-1-1):2013-08, VFR 2019, EN 50438:2013, ABNT NBR 16149:2013, ABNT NBR 16150:2013, NRS 097-2-1:2017 Edition 2, NBT 32004:2018
EMC
Safety
On-Grid
“The World's First Daisy-Chain Single Unit Microinverter”with extremely wide DC input operating voltage range (16-60V) and low start-up voltage (22V only).
Hoymiles single unit microinverter MI-300/MI-350/MI-400 is the perfect selection for PV system with uneven number of panel numbers with world's No.1 CEC weighted efficiency - 96.50% (peak efficiency - 96.70%) in 2015.
MI-300 / MI-350 / MI-400(1 X 60 cells or 1 X 72 cells)
Commonly used module power (W)Peak power MPPT voltage range (V)Start-up voltage(V)Operating voltage range (V)Maximum input voltage (V)Maximum input current (A)
Up to 380 / 440 / 50029~48 / 33~48 / 34~48
2216~60
6011.5 / 11.5 / 12.5
Mechanical DataAmbient temperature range (℃)Dimensions (W X H X D mm)Weight (kG)Enclosure ratingCooling
-40~+65178 X 153 X 28
1.98 (including 1.35m AC cable) Outdoor-IP67
Natural convection - No fans
EfficiencyCEC peak efficiencyCEC weighted efficiencyNominal MPPT efficiencyNighttime power consumption (mW)
96.70%96.50%99.80%
<50
Model
Input Data (DC)
Output Data (AC)Rated output power (W)Rated output current (A)Nominal output voltage (V)Nominal output voltage range (V)Nominal frequency/range (V)Power factorTotal harmonic distortionMaximum units per branch
300 1.36 / 1.30 / 1.25220 / 230 / 240
180~275 ¹50/45~55 ¹ or 60/55~65 ¹
>0.99<3%
16 / 16 / 16
4001.82 / 1.74 / 1.67220 / 230 / 240
180~275 ¹50/45~55 ¹ or 60/55~65 ¹
>0.99<3%
12 / 12 / 12
3501.59 / 1.52 / 1.46220 / 230 / 240
180~275 ¹50/45~55 ¹ or 60/55~65 ¹
>0.99<3%
14 / 14 / 14
2.4GHz Proprietary RF(Nordic)Hoymiles Monitoring System
HighlightsMaximum output power up to 300/350/400W; Adapted to 60 & 72 cells PV panelsPeak efficiency 96.70%; CEC weighted efficiency 96.50%Static MPPT efficiency 99.80%; Dynamic MPPT efficiency 99.76% in overcast weatherHigh reliability: NEMA6 (IP67) enclosure; 6000V surge protection