ROY COOPER Governw MICHAELS. REGAN Stcretary MICHAEL ABRACZINSKAS Dlndor November 27, 2018 Mr. Jason Haynes Plant Manager Duke Energy Progress, L LC 1700 Dunnaway Road Semora, NC 27343 NORTH CAROLINA Environmental Quality SUBJECT: Air Quality Pennit No. 01001T56 Facility ID: 7300029 Duke Energy Progress, TLC - Roxboro Steam Electric Plant Semora, Person County, North Carolina Fee Class: Title V PSD Class; Major Dear Mr. Haynes: In accordance with your completed Air Quality Perm it Applications for significant modifications of a Title V permit received November 29, 2017 and March 16, 2018, we are forwarding herewith Air Quality Permit No. 01001T56 to Duke Energy Progress, LLC - Roxboro Steam Electric Plant, Roxboro, Person County, North Carolina authorizing the construction and operation of the emission source(s) and associated air pollution control device(s) specified herein. Additionally, any emissions activities determined from your Air Quality Permit Application as being insignificant per 15A North Carolina Administrative Code 02Q .0503(8) have been listed for infonnational purposes as an ATTACHMENT. Please note the requirements for the annual compliance certification are contained in General Condition P in Section 3. The current owner is responsible for submitting a compliance certification for the entire year regardless of who owned the facility during the year. As the designated responsible official, it is your responsibility to review, understand, and abide by all of the tenns and conditions of the attached permit. It is also your responsibility to ensure that any person who operates any emission source and associated air pollution control device subject to any term or condition of the attached permit reviews, understands, and abides by the condition(s) of the attached permit that are applicable to that particular emission source. If any parts, requirements, or limitations contained in this Air Quality Permit are unacceptable to you, you have the right to request a formal adjudicatory hearing within 30 days following receipt of this permit, identifying the specific issues to be contested. This hearing request must be in the form of a written petition, conforming to NCGS (North Carolina General Statutes) 1508-23, and filed with both the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, North Carolina27699-6714 and the Division of Air Quality, Permitting Section, 1641 Mail Service Center, Raleigh, North Carolina 27699-1641. The fo1m for requesting a formal adjudicatory hearing may be obtained upon request from the Office of Administrative Hearings. Please note that this permit will be stayed in its entirety upon receipt of the request for a hearing. Unless a request for a hearing is made pursuant to NCGS 1 S0B-23, this Air Quality Pennit shall be final and binding 30 days after issuance. North Carolina Department of Environrnental Quality I DMsion of Air QuaHty 217 We,st Jones Strttt I 1641 Malt ~rv!ce Cmter I Raleigh. North Carolina 27699-1641 919.707.8400
93

MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Sep 28, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

ROY COOPER Governw

MICHAELS. REGAN Stcretary

MICHAEL ABRACZINSKAS Dlndor

November 27, 2018

Mr. Jason Haynes Plant Manager Duke Energy Progress, L LC 1 700 Dunnaway Road Semora, NC 27343

NORTH CAROLINA Environmental Quality

SUBJECT: Air Quality Pennit No. 01001T56 Facility ID: 7300029 Duke Energy Progress, TLC - Roxboro Steam Electric Plant Semora, Person County, North Carolina Fee Class: Title V PSD Class; Major

Dear Mr. Haynes:

In accordance with your completed Air Quality Perm it Applications for significant modifications of a Title V permit received November 29, 2017 and March 16, 2018, we are forwarding herewith Air Quality Permit No. 01001T56 to Duke Energy Progress, LLC - Roxboro Steam Electric Plant, Roxboro, Person County, North Carolina authorizing the construction and operation of the emission source(s) and associated air pollution control device(s) specified herein. Additionally, any emissions activities determined from your Air Quality Permit Application as being insignificant per 15A North Carolina Administrative Code 02Q .0503(8) have been listed for infonnational purposes as an ATTACHMENT. Please note the requirements for the annual compliance certification are contained in General Condition P in Section 3. The current owner is responsible for submitting a compliance certification for the entire year regardless of who owned the facility during the year.

As the designated responsible official, it is your responsibility to review, understand, and abide by all of the tenns and conditions of the attached permit. It is also your responsibility to ensure that any person who operates any emission source and associated air pollution control device subject to any term or condition of the attached permit reviews, understands, and abides by the condition(s) of the attached permit that are applicable to that particular emission source.

If any parts, requirements, or limitations contained in this Air Quality Permit are unacceptable to you, you have the right to request a formal adjudicatory hearing within 30 days following receipt of this permit, identifying the specific issues to be contested. This hearing request must be in the form of a written petition, conforming to NCGS (North Carolina General Statutes) 1508-23, and filed with both the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, North Carolina27699-6714 and the Division of Air Quality, Permitting Section, 1641 Mail Service Center, Raleigh, North Carolina 27699-1641. The fo1m for requesting a formal adjudicatory hearing may be obtained upon request from the Office of Administrative Hearings. Please note that this permit will be stayed in its entirety upon receipt of the request for a hearing. Unless a request for a hearing is made pursuant to NCGS 1 S0B-23, this Air Quality Pennit shall be final and binding 30 days after issuance.

North Carolina Department of Environrnental Quality I DMsion of Air QuaHty

217 We,st Jones Strttt I 1641 Malt ~rv!ce Cmter I Raleigh. North Carolina 27699-1641

919.707.8400

Page 2: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Mr. Jason Haynes November 27, 2018 Page 2

You may request modification of your Air Quality Pennit through informal means pursuant to NCGS 150B-22. This request must be submitted in writing to the Director and must identify the specific provisions or issues for which the modification is sought. Please note that this Air Quality Pennit will become final and binding regardless of a request for informal modification unless a request for a hearing is also made under NCGS lS0B-23.

The construction of new air pollution emission source( s) and associated air pollution control device( s ), or modifications to the emission source(s) and air pollution control device(s) described in this permit must be covered under an Air Quality Permit issued by the Division of Air Quality prior to construction unless the Perrnittee has fulfilled the requirements of NCGS l 43-2 l 5-108A(b) and received written approval from the Director of the Division of Air Quality to commence construction. Failure to receive an Air Quality Permit or written approval prior to commencing construction is a violation of NCGS 143-215.l0SA and may subject the Permittee to civil or criminal penalties as described in NCGS 143-215.114A and 143-215.114B.

Person County has triggered increment tracking under PSD for PM-10 and SO2. This modification will result in an increase in 0.048 pounds per hour of PM-10. 1bis permit modification does not conswne or expand the increment for S02.

This Air Quality Permit shall be effective from November 27, 2018 until September 30, 2023, is nontransferable to future owners and operators, and shall be subject to the conditions and limitations as specified therein.

Should you have any questions concerning these changes, please contact Edward L. Martin, P .E. at (919) 707-8739 or [email protected].

Enclosure

c: Raleigh Regional Office Connie Horne (cover page only) Central Files

it:: ~ L,\{ William D~ s, P.E., Chief, Pennitting Section y Division of Air Quality, NCDEQ

Page 3: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Mr. Jason H:aynes November 27, 2018 Page3

ATTACHMENT to Cover Letter to Air Quality Permit No. 010001T56 Duke Energy Progress, LLC - Roxboro Steam Electric Plant

Insignificant Activities under 15A NCAC 02Q .0503(8)

Emission Source Insignificant Emission Source Description LD.

IS-1 No. 2 fuel oil tank; 100,000 gallons

IS-2 No. 2 fuel oil tank; 500,000 gallons

IS-3 Lube oil storage tank; 8,000 gallons for Ul turbine lube oil

IS-4 Lube oil storage tank; 8,000 gallons for U2 turbine lube oil

IS-5 Two lube oil storage tanks; 9,000 gallons each for U3&4 turbine lube oil

IS-6 Bulk lube oil tank; 7,500 gallons at U3&4

IS-7 Batch lube oil tank; 12,000 gallons at U1&2

IS-8 Batch lube oil tank; 15,500 gallons at U3&4

IS-9 Gasoline tank; 1,500 gallons (Dozer shed)

IS-10 One kerosene tank; 250 gallons (Dozer shed)

IS-12 Two kerosene tanks; 1,000 gallons each for fuel oil farm\U3&4

IS-13 Ethylene glycol tank; 6,000 gallons

IS-14 Diesel tank; 250 gallons for IC turbine

IS-15 Diesel tank; 1,000 gallons (Bottom Ash off-road diesel)

IS-16 Diesel tank; 2,000 gallons (Charah shop off-road diesel)

IS-17 Ethylene glycol tank; 265 gallons (Dozer shed)

IS-18 Hydraulic oil storage tank; 500 gallons (Dozer shed)

IS-19 Engine oil storage tank; 500 gallons (Dozer shed)

IS-20 Assorted lube oil storage tanks; 55 to 265 gallons each

IS-21 Two used oil waste separator tanks; 1,000 gallons each

IS-22 Used oil portable tank; 285 gallons

IS-24 Two used oil portable tanks; 300 gallons each

IS-25 Fuel oil storage tank; 280 gallons for emergency fire pump at plant intake

IS-26 IC turbine lube oil reservoir; 1,800 gallons

IS-29 Vacuum cleaner outside near the dry flyash silos

IS-30 Four cooling towers that do not use chromate chemicals

IS-36 Fugitive emissions from coal handling/storage, plant parking lots, paved roads, unpaved roads, coal pile and ash handling

IS-37 Gypsum conveyor lA

IS-38 Gypsum emergency conveyor

IS-39 Gypsum conveyor I B

Page 4: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Mr. Jason Haynes November 27, 2018 Page4

Emission Source Insignificant Emission Source Description I.D.

IS-40 Emergency gypsum pile

IS-41 Mayo gypsum rotary feeder

IS-42 Mayo gypsum conveyor

IS-43 Gypsum conveyor 2

IS-44 Gypsum conveyor 3 (includes 3a and 3b)

IS-45 Off-specification gypsum pile

IS-46 On-specification gypsum pile

IS-47 Gypsum conveyor 4

IS-48 Landfill gypsum loading hopper

IS-49 Landfill gypsum rec1aim belt feeder

IS-50 Diesel tank; 10,500 off road diesel (Dozer shed)

IS-51 Unleaded gasoline tank, 500 gallons (Charah Shop)

IS-52 Diesel tank; 2,000 gallons (Charah Shop on-road diesel)

IS-53 Diesel Tank; 1,000 gallons (Charah Gypsum pad off-road diesel)

IS-54 Used oil shop tank; 125 gallons (Dozer shed)

IS-55 Fuel oil storage tank; 300 gallons for emergency fire pwnp at U3 cooling tower

IS-56 Portable fuel oil tank; 500 gallons at plant equipment shed

IS-57 Used oil tank; 500 gallons (Dozer shed)

IS-58 Portable kerosene tank; 280 gallons at fuel oil farm

IS-59 Diesel tank; 1,000 gallons at fuel oil farm (on-road diesel)

IS-60 Portable kerosene tank; 270 gallons at U4

IS-61

(MACT, ZZZZ; Leachate tank backup diesel-fired engine (150 kilowatts) NSPS; IIII)

IES-FWP2

(MACT, ZZZZ; one diesel-fired emergency fire water pump (175 horsepower) NSPS;IIII)

IES-31 one No. 2 fuel oil-fired emergency fire water pump (287 horsepower)

(MACT;ZZZZ)

IES-32A one propane-fired, spark ignition emergency generator (34 kilowatts)

(MACT; ZZZZ)

IES-32B one propane-fired, spark ignition emergency generator (34 kilowatts) (MACT; ZZZZ)

IS-62 Sodium Carbonate addition to Bottom Ash Tank

IS-HCl Wastewater treatment facility hydrochloric acid storage tank (10,000 gallon capacity) with HCI scrubber

Page 5: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Mr. Jason Haynes November 27, 2018 Page 5

Emission Source I.D. Insignificant Emission Source Description

IS-SA Sodium carbonate (soda ash) addition to bottom ash

1. Because an activity is insignificant does not mean that the activity is exempted from an applicable requirement or that the owner or operator of the source is exempted from demonstrating compliance with any applicable requirement.

2. When applicable, emissions from stationary source activities identified above shall be included in determining compliance with the permit requirements for toxic air pollutants under I SA NCAC 02D .1100 "Control of Toxic Air Pollutants" or 02Q .0711 "Emission Rates Requiring a Permit".

3. For additional information regarding the applicability of GACT see the DAQ page titled "The Regulatory Guide for Insignificant Activities/Permits Exempt Activities". The link to this site is as follows: http://deg.nc.!!ov/abouVdivisions/air-guality/air-guality-perm.its/specific-permit-conditions-regulatory-euide.

Page 6: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Mr. Jason Haynes November 27, 2018 Page 6

Summary of Changes to Permit

The following changes were made to the Duke Energy Progress, LLC - Roxboro Plant Air Permit No. 01001T55: Page Section Description of Change(s)

Cover -- Amended permit numbers and dates.

-- Insignificant Activities list Added wastewater treatment facility hydrochloric acid storage tank IS-HCl and sodium carbonate (soda ash) addition to bottom ash IS-SA.

4 l, table of permitted Renumbered CD-FS-1B to CD-FS-lC. emission sources

Added emission source ID No. ES-Surge Bin 3 and associated control device ID No. CD-BF15.

Removed emission source ID No. ES-FA Handling 3C and associated control device ID No, CD-FS-3C.

7 Removed wastewater treatment bioreactor ES-WWTBR.

8 Added wastewater treatment facility ES-WWTFBR (bio-reactor) and wastewater treatment facility lime storage silo ES-WWTF Silo.

8 Removed footnote f for the requirement to file a Title V Air Quality Permit Application for emission sources (ID Nos. ES-FA Handling 1, ES-FA Handling 3A, ES-FA Handling 3B, ES-FA Handling 3C, ES-FAHandling4A, ES-FA Handling 4B, ES-FA Handling 4C, ES-FA Silo 5 and ES-S-5) and control devices (ID Nos. CD-BF14, CD-FS-lA, CD-FS-lB, CD-FS-3A, CD-FS-3B, CD-FS-3C, CD-FS-4A, CD-FS-4B, CD-FS-4C, CD-BF9, CD-BFlO, CD-WS6 and CD-WS7).

23 2.1.C equipment Added Unit No. 3 dry flyash conveying system surge/transfer description tank (ID No. ES-Surge Bin 3) and associated bagfilter (ID No.

CD-BF15.

Removed Unit 3 dry flyash pneumatic transfer systems and filter separator ID No. ES-FA Handling 3C and associated bagfilter ID No. CD-FS-3C.

26 2.1.C.3.a Removed requirement to file an amended application. following the procedures of Section 15A NCAC 02Q .0500 within one year from the date ofbeginnmg operation for sources (ID Nos. ES-FA Handling I, ES-FA Handling 3A, ES-FA Handling 3B, ES-FA Handling 3C, ES-FA Handling 4A, ES-FA Handling 4B, ES-FA Handling 4C and ES-FA Silo 5) and associated air pollution control devices (ID Nos. CD-FS-lA, CD-FS-lB, CD-FS-3A, CD-FS-3B, CD-FS-3C, CD-FS-4A, CD-FS-4B, CD-FS-4C, CD-BF9 and CD-BFlO).

29 2.1.D.3.a Removed requirement to file an amended application.

Page 7: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Mr. Jason Haynes November 27, 2018 Page 7

43-44 2.1.K

45-50 2.2.A.1.a

Added condition for wastewater treatment facility lime storage silo ES-WWTF Silo.

Replaced wastewater treatment bioreactor ES-WWIBR with new wastewater treatment facility (bio-reactor) ES-WWTFBR.

Added wastewater treatment facility lime storage silo ES-WWTF Silo.

Replaced ES-FA Handling 3C with Surge Bin 3.

Updated toxic pernrit limits.

Page 8: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

State of North Carolina

Department of Environmental Quality

Division of Air Quality

AIR QUALITY PERMIT Permit No. Replaces Perm.it No. Effective Date Expiration Date

01001T56 01001 T55 November 27, 2018 September 30, 2023

Until such time as this perm it expires or is modified or revoked, the below named Permittee is penn itted to construct and operate the emission source(s) and associated air pollution control device(s) specified herein, in accordance with the terms, conditions, and limitations within this permit. This permit is issued under the provisions of Article 21 B of Chapter 143, General Statutes of North Carolina as amended, and Title 15A North Carolina Administrative Codes, Subchapters 02D and 02Q, and other applicable Laws.

Pursuant to Title 15A NCAC Subchapter 02Q, the Permittee shall not construct, operate, or modify any emission source(s) or air pollution control device(s) without having first submitted a complete air quality permit application to the permitting authority and received an Air Quality Permit, except as provided in this permit.

Permittee:

Facility ID:

Facility Site Location: City, County, State, Zip:

Mailing Address: City, State, Zip:

Application Numbers: Complete Application Date:

Primary SIC Code: Division of Air Quality, Regional Office Address:

Duke Energy Progress, LLC -Roxboro Steam Electric Plant 7300029

1700 Dunnaway Road Semora, Person County, NC 27343

1700 Dunnaway Road Semora, NC 27343

7300029.17C and 7300029.18A November 29, 2017 (.17C) and Ma1·ch 16, 2018 (.18A)

4911 Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609

Pennit issued this the 27th day of November, 2018.

//(1\A J , 0L L ~ { William D. Willets, P ., Chief, Permitting Section \ By Authority of the Environmental Management Commission

Page 9: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Table Of Contents

SECTION 1: PERMITTED EMISSION SOURCE(S) AND ASSOCIATED AlR POLLUTION CONTROL DEVICE(S)

SECTION 2: SPECJFIC LIMITATIONS AND CONDITIONS

2.1- Emission Source(s) Specific Limitations and Conditions (Including specific requirements, monitoring/testing, record.keeping, and reporting requirements)

2.2- Multiple Emission Source(s) Specific Limitations and Conditions (Including specific requirements, testing, monitoring, record.keeping, and reporting requirements

2.3- Permit Shield for Nonapplicable Requirements

2.4- Phase II Acid Rain Pennit Requirements

SECTION 3: GENERAL PERMIT CONDITIONS

ATTACHMENTS;

l . List of Acronyms

2. Phase II Acid Rain Permit Renewal Application and NOx Averaging Plan, dated April 4, 2018

3. Phase II NOx Compliance Plan, dated June 23, 2015

Page 10: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Page

9 51 63

9 51 63

9 51 63

.Air Quality Permit No. 0100 l T56 Page 3

SECTION 1- PERMITTED EMISSION SOURCE(S} AND ASSOCIATED AIR POLLUTION CONTROL DEVI~E(S)

The following table contains a summary of all permitted emission sources and associated air pollution control devices:

Emission Source I.D. No.

ES-Unit l MACT, UUUUU

ES-Unit2

MACT,UUUUU

ES-Unit 3A and ES-Unit 3B

MACT, UUUUU

Emission Source Description

coal/No. 2 fuel oiP-fired electric utility boiler (4,722 million Btu per hour nominally rated heat input) equipped with low-NOx burner and alkaline-based fuel additiveb,c,

coal/No. 2 fuel oila-fired electric utility boiler (7,035 million Btu per hour nominally rated heat input) equipped with low-NOx burner and alkaline-based fuel additiveh,c.

two coal/No. 2 fuel oil"-fired electric utility boilers (4,261 million Btu per hour nominally rated heat input each) equipped with low-NOx burners and alkaline-based fuel additiveb,c.

Control Device I.D. No.

CD-SCRld

CD-FGDle

CD-INJ-Sorbl

Control Device Description

a selective catalytic reduction system

electrostatic precipitator (Environmental Elements cold-side model)

wet scrubber

(consisting of ES-SORB-17 sorbent injection system and ES-SORB-19)

CD-SCR2d

CD-ESP2

CD-FGD2e

CD-INJ-Sorb2

selective catalytic reduction system

electrostatic precipitator (Environmental Elements cold-side model)

wet scrubber

(consisting of ES-SORB-13 sorbent injection system and ES-SORB-15)

CD-SCR3a & CD-SCR3bd

CD-ESP3a & CD-ESP3b

CD-FGD3e

CD-INJ-Sorb3

two selective catalytic reduction systems ( one per boiler)

two electrostatic precipitators (Lodge-Cottrell cold-side model; one per boiler)

wet scrubber

(consisting ofES-SORB-9 sorbent injection system and ES-SORB-11)

Page 11: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Page

18 51 63

23 45

23 45

23 45

23 46

23 46

23 46

23 46

23 46

27 46

27 46

27 47

Air Quality Permit No. 01001 T56 Page 4

Emission Source Emission Source Description LD.No.

ES-Unit 4A and two coal/No. 2 fuel oila-fired ES-Unit 4B electric utility boilers (4,099 NSPS, D; million Btu per hour nominally MACT, UUUUU rated heat input each) equipped

with low-NOx burners and alkaline-based fuel additiveb,c.

Unit 1 dry flyash pneumatic ES-FA Handling 1 transfer system including surge

bin and filter separators

ES-Surge Bin 3 Unit No. 3 dry flyash conveying system surge/transfer tank

ES-FA Handling 3A Unit 3 dry flyash pneumatic ES-FA Handling 3B transfer systems and filter

separators

ES-FA Handling 4A Unit 4 dry flyash pneumatic ES-FA Handling 4B transfer systems and filter ES-FA Handling 4C separators

ES-FA Silo 1 flyash conveying system storage and handling silo

ES-FA Silo 2 flyash conveying system storage and handling silo

ES-FA Silo 4 flyash conveying system storage and handling silo

ES-FA Silo 5 flyash conveying system storage and handling silo No. 5

No. 1 flyash conveying system ES-S-1 storage and handling silo and

load-out stations

No. 4 flyash conveying system ES-S-4 storage and handling silo and

load-out stations

No. 5 flyash conveying system ES-S-5 storage and handling silo and

load-out station

Control Device I.D. No. Control Device Description

two selective catalytic CD-SCR4a & CD-SCR4bd reduction systems ( one per

boiler)

eight electrostatic CD-ESP4a through CD-ESP4h

precipitators (Buell hot-side model; four per boiler)

CD-FGD4e wet scrubber

CD-INJ-Sorb4 (consisting ofES-SORB-5 sorbent injection system and ES-SO RB-7)

CD-BF14, three bagfilters ( one with 164

CD-FS-lA, and square feet of filter area and

CD-FS-lC two with 727 square feet of filter area each)

CD-BF15 bin vent filter ( 515 square feet of filter area)

CD-FS-3A and CD-FS-3B two bagfilters (727 square feet of filter area each)

CD-FS-4A, three bagfilters (727 square

CD-FS-4B, and CD-FS-4C

feet of filter area each)

CD-BFl and CD-BF2 two bagfilters (2,450 square feet of filter area, each)

CD-BF3 and CD-BF4 two bagfilters (2,450 square feet of filter area, each)

CD-BF7 and CD-BPS two bagfilters (2,450 square feet of filter area, each)

CD-BF9and two bagfilters (3,534 square CD-BF10 feet of filter area each)

CD-WSl and CD-WS2 five wet flyash conditioners (minimum ten percent by

CD-WS3, CD-WS4, and weight water injection rate)

CD-WS5

CD-WS6and CD-ws7Error! Booknurk oot two flyash mixer conditioners detlned.

Page 12: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Page

23 47

23 47

30 47

23 47

23 48

23 48

30 47

32 48

32 48

32 48

33-34, 43-49

35 48

Air Quality Permit No. 01001 T56 Page 5

Emission Source Emission Source Description LO.No.

electrostatic flyash separation ES-S-3L system and mineral-rich product

load-out silo

ES-EFSSl two electrostatic tlyash

ES-EFSS2 separation systems and associated conveying systems

ES-Coal Silo 1 ES-Coal Silo 2 ES-Coal Silo 3 ES-Coal Silo 4 six coal storage silos ES-Coal Silo 5 ES-Coal Silo 6 NSPS, Y

ES-SVSl stationary vacuum system for housekeeping

ES-FA Silo 3 flyash conveying system storage and handling silo

mineral-rich flyash loadout

ES-S-3L2 system (28 tons per hour nominal filling rate and 300 tons per hour nominal unloading rate)

ES-37A, ES-37B, ES-39A, ES-39B four coal conveyors (375 tons per

NSPS, Y hour nominal rated capacity each)

ES-Coal Hopper coal unloading hopper (4,800

NSPS, Y tons per hour nominal rated capacity) with wet suppression

ES-Coal Conv 1 925 feet long x 72 inches wide

NSPS, Y coal conveyor (4,800 tons per hour nominal rated capacity)

ES-Coal Conv 2 425 feet long x 72 inches wide

NSPS, Y coal conveyor (4,800 tons per hour nominal rated capacity)

limestone rail unloading station

ES-LS Rail (2,200 tons per hour nominal rated capacity) with wet suppression

ES-LS Unload A ES-LS UnloadB two limestone unloading hoppers NSPS,000

Control Device J.D. No. Control Device Description

CD-BF23 bagfilter ( 680 square feet of filter area)

CD-BF24 bagfilter (1,554 square feet of filter area)

NA NA

bagfilter (integral to vacuum CD-BF26 system)

CD-BFS and two bagfilters (2,450 square CD-BF6 feet of filter area each)

NA NA

NA NA

NA NA

NA NA

NA NA

NA NA

Page 13: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Page

35 48

35 48

35 49

35

49

35 37 48

35 37

48

37 48

37 49

Air Quality Permit No. 01001 T56 Page 6

Emission Source Emission Source Description I.D. No.

ES-LS Feeder 1 37 feet long x 72 inches wide belt feeder (2,200 tons per hour

NSPS,000 nominal rated capacity) with enclosed transfer

471 feet long x 48 inches wide

ES-LS Convey 2 covered limestone conveyor (2,200 tons per hour nominal

NSPS,000 rated capacity) with telescopic chute for dust control while stockpiling

ES-LS Reclaim A two limestone reclaim hoppers ES-LS Reclaim B located under limestone stockpile NSPS,000 with enclosed transfer

ES-LS Feeder 3A two 20 feet long x 36 inches wide

ES-LS Feeder 3B belt feeders ( 480 tons per hour nominal rated capacity each) with

NSPS,000 enclosed transfer

610 feet long x 30 inches wide

ES-LS Convey4A covered limestone conveyor ( 480 tons per hour nominal rated NSPS,000 capacity) with enclosed transfer and head•end dust collection

610 feet long x 30 inches wide

ES-LS Convey 4B covered limestone conveyor ( 480

NSPS,000 tons per hour nominal rated capacity) with enclosed transfer and head-end dust collection

42 feet long x 30 inches wide limestone conveyor ( 480 tons per ES-LS Convey 5 hour nominal rated capacity) that

NSPS,000 feeds Limestone Silo A and has enclosed transfer dust collection

42 feet long x 30 inches wide limestone conveyor ( 480 tons per

ES-LS Convey 6 hour nominal rated capacity) that NSPS,000 can feed either Limestone Silo C

or Limestone Conveyor 7 and has enclosed transfer dust collection

Control Device I.D. No. Control Device Description

NA NA

NA NA

NA NA

NA NA

bagfilter (2,655 square feet of filter area) installed common to head-end transfer points of

CD-LB·BF-1 Conveyers 4A, 4B, 5, and 6, to tail-end transfer points of Conveyors 5, 6, 7, and to Limestone Silos A, B, and C

Page 14: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Page

37 49

37

49

37 49

37-38, 43.49

35 49

40

40

40

40

Air Quality Permit No. 0 I 00 I T56 Page 7

Emission Source Emission Source Description I.D. No.

198 feet long x 30 inches wide limestone conveyor ( 480 tons per

ES-LS Convey 7 hour nominal rated capacity) that NSPS,000 feeds the Mayo Limestone Silo

and has enclosed transfer dust collection

ES-LS Silo A

ES-LS Silo B three limestone silos (572

ES-LS Silo C tons/13,468 cubic feet storage capacity each)

NSPS,000

limestone silo storing material for ES-LS Mayo Silo

NSPS,000 Mayo plant (600 tons/14,117 cubic feet storage capacity)

ES-Truck Spout truck loading spout from Mayo NSPS,000 Limestone Silo

ES-LS Grinder 1

ES-LS Grinder 2 three wet limestone grinders (50

ES-LS Grinder 3 tons per hour nominal rated

NSPS,000 limestone capacity)

ES-SORB-5 stationary sorbent Silo 1 for Unit 4

Unit 4 Silo 1 pneumatic

ES-SORB-7 conveying equipment system (4,000 pounds per hour maximum capacity)

ES-SORB-9 stationary sorbent Silo 1 for Unit 3

Unit 3 Silo 1 pneumatic

ES-SORB-11 conveying equipment system (4,000 pounds per hour maximum capacity)

Control Device I.D. No. Control Device Description

bagfilter (2,655 square feet of filter area) installed common to head-end transfer points of

CD-LB-BF-1 Conveyers 4A, 4B, 5, and 6, to tail-end transfer points of Conveyors 5, 6, 7, and to Limestone Silos A, B, and C

bagfilter (641 square feet of

CD-LB-BF-2 filter area) installed common to Mayo Limestone Silo and head-end of Conveyor 7

bagfilter (2,655 square feet of filter area) installed common to head-end transfer points of

CD-LB-BF-1 Conveyers 4A, 4B, 5, and 6, to tail-end transfer points of Conveyors 5, 6, 7, and to Limestone Silos A, B, and C

bagfilter (641 square feet of filter area) installed common

CD-LB-BF-2 to Mayo Limestone Silo and head-end of Conveyor 7

CD-LB-BF-3 bagfilter ( 480 square feet of filter area)

NA NA

CD-SORB-5 bagfilter (1.6: 1 air-to-cloth ratio)

NA NA

CD-SORB-9 bagfilter (1.6: I air-to-cloth ratio)

NA NA

Page 15: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Page

40

40

40

40

43

45

45

Air Quality Permit No. 01001 T56 Page 8

Emission Source Emission Source Description I.D. No.

ES-SORB-13 stationary sorbent Silo 1 for Unit 2

Unit 2 Silo 1 pneumatic

ES-SORB-15 conveying equipment system (4,000 pounds per hour maximum capacity)

ES-SORB-17 stationary sorbent Silo 1 for Unit 1

Unit 1 Silo 1 pneumatic

ES-SORB-19 conveying equipment system (4,000 pounds per hour maximum capacity)

ES-WWTF Silo wastewater treatment facility lime storage silo (5,600 cubic feet capacity)

ES-WWTFBR wastewater treatment facility (bio-reactor)

Control Device I.D. No. Control Device Description

CD-SORB-13 bagfilter ( 1. 6: 1 air-to-cloth ratio)

NA NA

CD-SORB-17 bagfilter (1.6:1 air-to-cloth ratio)

NA NA

CD-WWTF-Silo-BF bin vent filter (295.2 square feet of filter area)

NA NA

a Incidental spills of oil, antifreeze, etc. that might get on the coal from mobile equipment is allowed to be burned in these boilers.

b Alkaline-based fuel additive may be used on an as-needed basis not to exceed 4 pounds per ton of coal burned. Fuel additives shall not contain any toxic air pollutants listed in 15A NCAC 02Q .0711.

c None of the mercury control devices or techniques shall use halogen containing compounds (for example, bromide).

d For ozone season NOx control and compliance with the North Carolina Clean Smokestacks Act (SB 107 8 - Air Quality/Electric Utilities Bill). Operated on an as needed basis.

e For compliance with the North Carolina Clean Smokestacks Act (SB 1078 -Air Quality/Electric Utilities Bill) and the Phase II Acid Rain permit requirements. Operated on an as needed basis.

Page 16: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. OJ 001 '1'56 Page 9

SECTION 2- SPECIFIC LIMITATIONS AND CONDITIONS

2.1- Emission Source(s) Specific Limitations and Conditions

The emission source(s) and associated air pollution control device{s) listed below are subject to the following specific terms, conditions, and limitations, including the monitoring, recordkeeping, and reporting requirements specifically identified herein as applicable requirements:

A. Boiler Units 1, 2, and 3:

• coal/No. 2 fuel oil-fired electric utility boiler equipped with low-NOx burner and Mg(OH)2 fuel additive (ID No. ES-Unit 1) and associated selective catalytic reduction system (ID No. CD-SCRI) installed in series with electrostatic precipitator (ID Nos. CD-ESPl), in series with a wet scrubber (ID No. CD-FGDl), and sorbent injection system (ID No. CD-INJ-Sorbl)

• coaJ/No. 2 fuel oil-fired electric utility boiler equipped with low-NOx burner, Mg(OH)2 fuel additive (ID No. ES-Unit 2) and associated selective catalytic reduction system (ID No. CD-SCR2) installed in series with electrostatic precipitator (ID No. CD-ESP2), in series with a wet scrubber (ID No. CD­FGD2), and sorbent injection system (ID No. CD-INJ-Sorb2)

• two coal/No. 2 fuel oil-fired electric utility boilers each equipped with low-NOx burners, Mg(OH)2 fuel additive (ID Nos. ES-Unit 3A and ES~Unit 3B) and associated selective catalytic reduction systems (ID Nos. CD-SCR3a and CD-SCR3b) installed in series with two electrostatic precipitators (ID Nos. CD­ESP3a and CD-ESP3b), in series with a wet scrubber (ID No. CD-FGD3), and sorbent injection system (ID No. CD-INJ-Sorb3)

The followin table provides a summaiy of limits and standards for the emission source(s) described above:

Regulated Limits/Standards Applicable Regulation Pollutant

sulfur dioxide 0.547 pounds per million Btu heat input 15A NCAC 02D .0501(c)

Phase II Acid Rain Permit Requirements 15A NCAC 02Q .0402 (see Section 2.4) ( 40 CFR Part 72)

(Federally Enforceable Only) 40 CFR Part 97, Cross State Air Pollution Rule Requirements Subpart CCCCC (see Section 2.2 B.)

particulate matter As determined by stack test: 15A NCAC 02D .0536 Unit 1 Boiler - 0.25 pounds per million Btu heat input Unit 2 Boiler - 0.16 pounds per million Btu heat input Unit 3A Boiler - 0.10 pounds per million Btu heat input Unit 3B Boiler - 0.10 pounds per million Btu heat input As determined by PM CEMS: 0.030 pounds per million Btu heat input (or 0.30 pounds perMWh)

Page 17: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Page 10

Regulated Limits/Standards

Pollutant

nitrogen oxides See Section 2.1 A 1.

1.066 pounds per million Btu heat input, or when burning oil: the limit given in Section 2.1 A.1, whichever is lower

Phase II Acid Rain Permit Requirements (see Section 2.4)

(Federally Enforceable Only) Cross State Air Pollution Rule Requirements (see Section 2.2 B.)

visible emissions 40 percent opacity

State-only Requirement Unit 1 Boiler - 15 percent annual average opacity Unit 2 Boiler - 20 percent annual average opacity Unit 3A Boiler - 25 percent annual average opacity Unit 3B Boiler - 25 percent annual average opacity

malfunction as defined in specific conditions abatement plan

excess emissions/ as defined in specific conditions good operating and maintenance practices

Hazardous Air See Section 2.2 B.2 Pollutants

Applicable Regulation

l 5A NCAC 02D .0519

15A NCAC 02D .0501(c)

15ANCAC 02Q .0402 ( 40 CFR Part 72)

40 CFR Part 97, Subparts AAAAA and BBBBB

15ANCAC 02D .0521

lSANCAC 02D .0536

15A NCAC 02D .0535

15A NCAC 02D .0606

15A NCAC 02D .1111 (40 CPR 63, Subpart UUUUU)

1. 15A NCAC 02D .0519: CONTROL OF NITROGEN OXIDES EMISSIONS

a. Emissions of nitrogen oxides from these so\urces (ID Nos. ES-Unit 1, ES-Unit 2, ES-Unit 3A, and ES­Unit 3B) when burning coal and/or oil shall be calculated by the following equation:

E = [(Ec)(Qc) + (Eo)(Qo)]/Qt where:

E = emission limit for combined burning of coal and oil or gas in pounds per million Btu heat input

Ee= 1.8 pounds per million Btu heat input for coal only Eo = 0.8 pounds per million Btu heat input for oil or gas Qc = coal heat input in Btu per hour Qo = oil and gas heat input in Btu per hour Qt= Qc+Qo

Testing fl SA NCAC 02Q .0508(t)] b. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of lhis test are above the limit given in Section 2.1 A.1.a. above, the Permittee shall be deemed in noncompliance with 15ANCAC 02D .0519.

Page 18: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 01001 T56 Page 1 l

Monitoring/Recordkeeping (15A NCAC 02Q .0508(f)] c. The Permittee shall ensure compliance with 15A NCAC 02D .0519 by determining nitrogen oxide

emissions in pounds per million Btu using a continuous emissions monitoring (CEM) system meeting the requirements of 40 CFR Part 75, except that unbiased values may be used (missing data shall be filled in accordance with 40 CFR Part 75), Compliance with this emission standard shall be determined by averaging hourly continuous emission monitoring system values over a 24-hour block period beginning at midnight. To compute the 24-hour block average, the average hourly values (missing data shall be filled in accordance with 40 CFR Part 75) shall be summed, and the sum shall be divided by 24. The minimum number of data points, equally spaced, required to determine a valid hour value shall be determined by 40 CFR Part 75. For monitoring purposes, the following emission limits will apply:

1. When only coal is burned, the emission limit shall be 1.8 pounds per million Btu heat input.

ii. When only oil or gas is burned, the emission limit shall be 0.8 pounds per million Btu heat input.

iii. When oil or gas is bumed other than for startup and for periods greater than 24 hours, the emission limit shall be calculated in accordance with the equation in Section 2.1 A. l .a. above.

If any 24-hour block average exceeds the emission limit, the Permittee shall be deemed in noncompliance with l5ANCAC 02D .0519.

d. The Perrnittee shall maintain records of monthly coal and oil consumption (written or electronic form) and shall submit such records within 30 days of a request by DAQ. The Permittee shall be deemed in noncompliance with 15A NCAC 02D .0519 if these records are not maintained.

Reporting [lSA NCAC 02Q .508(f)] e. The Perrnittee shall submit the continuous emissions monitoring system data showing the 24-hour daily

block values for periods of excess nitrogen oxide emissions postmarked on or before January 30 of each calendar year for the preceding six-month period between July and December and July 30 of each calendar year for the preceding six-month period between January and June. All instances of deviations from the requirements of this permit must be clearly identified.

f. CEMs Monitor Availability - The Pennittee shall submit the nitrogen oxide CEM systems monitor downtime reports, including monitor availability values ( as calculated for 40 CFR Part 7 5) for the last hour of the reporting period, postmarked on or before January 30 of each calendar year for the preceding six­month period between July and December and July 30 of each calendar year for the preceding six-month period between January and June.

2. 15A NCAC 02D .0501(c): COMPLIANCE Wim EMISSION CONTROL STANDARDS

a. In addition to any control or manner of operation necessary to meet emission standards in 15A NCAC 02D .0500, any source of air pollution shall be operated with such control or in such manner that the source shall not cause the ambient air quality standards of ISA NCAC 02D .0400 to be exceeded at any point beyond the premises on which the source is located. When controls more stringent than named in the applicable emission standards in 15A NCAC 02D .0500 are required to prevent violation of the ambient air quality standards or are required to create an offset, the permit shall contain a condition requiring these controls.

b. In order to comply with the National Ambient Air Quality Standards (NAAQS) for sulfur dioxide1,

emissions of sulfur dioxide from these sources (JD Nos. ES-Unit 1, ES-Unit 2, ES-Unit 3A, and ES-Unit 3B) shall not exceed 0.547 pounds per million Btu heat input in accordance with the modeling analysis

1 61 Fed. Reg. 25566 (May 22, 1996)

Page 19: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 010011'56 Page 12

received May 16, 2007. Sulfur dioxide formed by the combustion of sulfur in fuels, wastes, ores, and other substances shall be included when determining compliance with this standard.

c. In order to comply with the NAAQS for nitrogen dioxide2, emissions of nitrogen oxides from these sources (ID Nos. ES-Unit 1, ES-Unit 2, ES-Unit 3A, and ES-Unit 3B) shall not exceed either 1.066 pounds per million Btu heat input (in accordance with the modeling analysis received May 16, 2007) or the limit in Section 2.1 A. I .a above when burning oil, whichever is lower.

Testing [15A NCAC 02Q .0508(f)] d. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limits given in Sections 2.1 A.2. b or c above, the Pennittee shall be deemed in noncompliance with 15A NCAC 02D .OSOl(c).

Monitoring/Recordkeeping rI SA NCAC 02Q .0508(±) and 02D .0608] e. The Permittee shall ensure compliance with 15A NCAC 02D .0501(c) by determining sulfur dioxide and

nitrogen oxides emissions in pounds per million Btu using continuous emissions monitoring (CEM) systems meeting the requirements of 40 CFR Part 75, except that unbiased values may be used (missing data shall be filled in accordance with 40 CFR Part 75). Compliance with sulfur dioxide and nitrogen oxides emission standards shall be determined by averaging hourly continuous emission monitoring system values over a 24-hour block period beginning at midnight. To compute the 24-hour block average, the average hourly values (missing data shall he filled in accordance with 40 CFR Part 75) shall be summe4 and the sum shall be divided by 24. The minimum number of data points, equally spaced, required to determine a valid hour value shall be determined by 40 CFR Part 75. If any 24-hour block average exceeds the limits given in Sections 2.1 A.2.b or c above or records are not maintaine4 the Permittee shall be deemed in noncompliance with 15A NCAC 02D .0501 ( c ).

Reporting [15A NCAC 02Q .0508(f)] f. The Permittee shall submit the continuous emissions monitoring data showing the 24-hour daily block

values in pounds per million Btu for each 24-hour daily block averaging period during the reporting period postmarked on or before January 30 of each calendar year for the preceding three-month period between October and December, April 30 of each calendar year for the preceding three-month period between January and March, July 30 of each calendar year for the preceding three-month period between April and June, and October 30 of each calendar year for the preceding three-month period between July and September. All instances of deviations from the requirements of this permit must be clearly identified.

g. CEMs Monitor Availability - The Permittee shall submit sulfur dioxide and nitrogen oxides CEM systems monitor downtime reports, including monitor availability values {as calculated for 40 CFR Part 75) for the last hour of the reporting period, postmarked on or before January 30 of each calendar year for the preceding three-month period between October and December, April 30 of each calendar year for the preceding three­month period between January and March, July 30 of each calendar year for the preceding three-month period between April and June, and October 30 of each calendar year for the preceding three-month period between July and September.

3. ISA NCAC 02D .0521: CONTROL OF VISIBLE EMISSIONS

a. Visible emissions shall not be more than 40 percent opacity when averaged over a six-minute period except that six-minute periods averaging not more than 90 percent opacity may occur not more than once in any hour nor more than four times in any 24-hour period.

2 61 Fed. Reg. 52852 (October 8, 1996)

Page 20: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Page 13

Testing [15A NCAC 02Q .0508(t)] b. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limit given in Section 2. l A.3.a above, the Pennittee shall be deemed in noncompliance with 15A NCAC 02D .0521.

Monitoring/Recordkeeping/Reporting [15A NCAC 02Q .0508(f)] c. No monitoring/recordkeeping/reporting is required to demonstrate compliance with 15A NCAC 02D .0521

for these sources (ID Nos. ES-Unit 1, ES-Unit 2, ES-Unit 3A, and ES-Unit 3B).

4. 15A NCAC 02D .0535: EXCESS EMISSIONS REPORTING AND MALFUNCTIONS

a. All electric utility boiler units shall have a malfunction abatement plan approved by the Director as specified in 15A NCAC 02D .0535(d).

Monitoring/Recordkeeping rI5A NCAC 02Q .0508(±)] b. The Perrnittee shall maintain logs to show that the operation and maintenance parts of the malfunction

abatement plan are implemented. These logs (written or electronic form) shall be subject to inspection by DAQ personnel upon request during business hours. The Permittee shall be deemed in noncompliance with 15A NCAC 02D .0535 if these records are not maintained.

5, 15A NCAC 02D .0536: PARTICULATE EMISSIONS FROM ELECTRIC UTILITY BOILERS

a. Emissions of particulate matter from these sources shall not exceed the following as determined by stack test:

Boiler Limit Ob/MMBtu)

Unit 1 Boiler 0.25

Unit 2 Boiler 0.16

Unit 3A Boiler O.lO Unit 3B Boiler 0.10

b. Any use of the electrostatic precipitator high voltage control Energy Management System (EMS) feature requires a revision to this permit.

Testing (15A NCAC 02Q .0508(f)] c. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. lf

the results of this test are above the limits given in Section 2.1 A.5 .a. above, the Permittee shall be deemed in noncompliance with ISA NCAC 02D .0536.

d. Once per calendar year, the Permittee shall conduct a stack test for particulate matter in accordance with either Method 5 at a sample temperature of 320° ± 25° F as described in §63 .100 l 0(i)(l) or Method 5B of Appendix A of 40 CPR Part 60. In the event that a boiler exceeds 80 percent of its particulate emission limit during the stack test, the Permittee shall schedule and conduct another stack test within six months. Upon demonstration that the source is operating under 80 percent of its particulate limit, as shown by three consecutive semiannual stack tests, the source may resume annual stack tests. If the result of any stack test is greater than the limits given in Section 2.1 A.5.a, the Pennittee shall be deemed in noncompliance with 15A NCAC 02D .0536.

Page 21: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennii .0lo. 0 l 001 T56 Page 14

Monitoring/Recoi·dkeeping ~15A NCAC 02Q .0508(f)] e. Compliance with the particulate limit in Section 2.1 A.5.a shall be determined using the PM CEMS. A

measured exceedance of O .030 pounds per million Btu heat input (30-boiler operating day rolling average) or 0.30 pounds per MWh (30-boiler operating day rolling average) shall be a violation of the corresponding emission standards in Section 2.1 A.5.a.

1. The Permittee shall install, certify, operate, and maintain a PM CEMS and record the output of the PM CEMS according to the applicable Maximum Achievable Control Technology (MACT) standards in §63.lOOlO(i) of 40 CFR Part 63 Subpart UUUUU, as specified in Section 2.2.B.2.cc. The PM CEMS shall meet the requirements of Performance Specification PS-11 of Appendix B of 40 CFR Part 60. The Permittee shall have on file with the director an approved quality assurance program, and shall submit to the director within the time period of his request for his approval a revised quality assurance program to include the provisions of 40 CFR 60, Appendix F, Procedure 2 for the PM CEMS.

11. The PM emission rate shall be determined based on a 30-boiler operating day rolling average of the hourly arithmetic average emissions concentrations using the CEMS outlet data for each boiler operating day (as defined below), except for data obtained during periods of startup or shutdown. Periods of malfunction shall be included in the emissions calculations.

A boiler operating day means a 24-hour period that begins at midnight and ends the following midnight during which any fuel is combusted at any time in the EGU, excluding startup periods or shutdown periods. It is not necessary for the fuel to be combusted the entire 24-hour period.

iii. Data from the PM CEMS shall be reduced to I -hour averages computed from four or more data points equally spaced over each 1-hour period, except during periods when calibration, quality assurance, or maintenance activities pursuant to provisions of 40 CFR Part 63 are being performed. During these periods, a valid hourly average shall consist of at least two data points with each representing a 15-minute period. Alternatively, an arithmetic or integrated 1-hour average of CEMS data may be used. Time periods for averaging are defined in §63.2. [§.63.8(g)(2)J

iv. PM CEMS monitor availability shall be calculated and reported.

v. The Permittee shall record the output of the PM CEMS as specified in Section 2.2 B.2.ee.

If the results of the arithmetic 30-boiler operating day rolling average PM CEMS concentration exceeds the limit in this section or any of the above requirements are not met, the Permittee shall be deemed in noncompliance with 1 SA NCAC 02D .0536.

Reporting [15A NCAC 02Q .0508(f)] f. The Permittee shall submit excess emissions and monitoring system perfonnance reports for PM in

accordance with the reporting requirements given in Section 2.1 A.7 .d postmarked on or before January 30 of each calendar year for the preceding three-month period between October and December, April 30 of each calendar year for the preceding three-month period between January and March, July 30 of each calendar year for the preceding three-month period between April and June, and October 30 of each calendar year for the preceding three-month period between July and September. The compliance report shall include, at a minimum, the in formation required in 40 CPR 63 .10 and contain the information specified in Section 2.2 B.2.ss, along with all 30-boiler operating day rolling average excess emissions (pounds per million Btu or pounds per MWh) using the CEMS outlet data, including periods exempted du.ring periods of startup and shutdown.

g. The results of any stack test shall be reported within 30 days, and the test report shall be submitted within 60 days after the test.

Page 22: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Page 15

h. All instances of deviations from the requirements ofthis permit must be clearly identified.

State-enforceable Only 6. 15A NCAC 02D .0536: ANNUAL AVERAGE OPACITY FOR ELECTRIC UTILITY BOILERS

a. Visible emissions from the utility boiler units shall not exceed the following:

ID No. Average Annual

Opacity

ES-Unit 1 15 percent

ES-Unit 2 20 percent

ES-Unit 3A 25 percent

ES-Unit 3B 25 percent

b. The Permittee shall calculate each day an annual average opacity value for the most recent 365-day period ending with the end of the previous day. The average is the sum of the measured non-overlapping one­hour averages of opacity determined only while the unit is in operation divided by the number of such measured non-overlapping one-hour averages. Start-up, shut-down, and non-operating time shall not be included in the annual average opacity calculation, but malfunction time shall be included. The hourly opacity values shall be determined using the PM CEMS hourly average output values as follows:

Where:

(Z) Opacity [average for each hour] = (A) (Y)

A = Actual PM CEMS output ( average for each hour, in milligrams per cubic meter [ mg/m3]);

Y =The average PM CEMS output value (in mg/m3) established during the initial PM CEMS PS-11

certification procedure at or near, but no greater than, the annual average opacity (AAO) limit. A concurrent Method 9 test shall be conducted during the PM CEMS measurements to determine opacity. At least 60 minutes of PM CEMS and Method 9 data shall be averaged.

Z = The average concurrent Method 9 opacity readings obtained during the initial PM CEMS PS-11 certification procedure corresponding to the PM CEMS measurements for Y above.

Recordkeeping/Reporting [15ANCAC 02D .0536] c. The Permittee shall submit a report showing the calculated annual average opacity of each unit and the

annual average opacity limit for each day during the reporting period postmarked on or before January 30 of each calendar year for the preceding three-month period between October and December, April 30 of each calendar year for the preceding three-month period between January and March, July 30 of each calendar year for the preceding three-month period between April and June, and October 30 of each calendar year for the preceding three-month period between July and September. All instances of deviations from the requirements of this permit must be clearly identified.

Page 23: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pcnnit No. OJ 001 T56 Page 16

7. 15A NCAC 02D .0606: SOURCES COVERED BY APPENDIX P OF 40 CFR PART 51 (CONTINUOUS OPACITY MONITORING, CONTINUOUS EMISSIONS MONITORING FOR SO2, AND EXCESS EMISSIONS)

Monitoring/Recordkeeping n 5A NCAC 02Q .0508(f)J a. The alternative monitoring and recordkeeping procedure in this section (Section 2.1 A.7.a) applies as

allowed by Paragraph 3.9 of Appendix P of 40 CFR Part 51. The Permittee shall install, certify, operate, and maintain a PM CEMS to monitor and record PM emissions according to the applicable Maximum Achievable Control Technology (MACT) standards in §63.lOOlO(i) of 40 CFR Part 63 Subpart UUUUU, as specified in Section 2.2.B.2.dd.

The quarterly excess emissions (EE) reports shall be used as an indication of good operation and maintenance of the electrostatic precipitators. These sources shall be deemed to be properly operated and maintained if the percentage of time the PM emissions, calculated on a one-hour average, greater than 0.030 pounds per million Btu heat input does not exceed 3.0 percent of the total operating time for any given calendar quarter, adjusted for monitor downtime (MD) as calculated below, except that Total Excess Emission Time contains all one-hour periods greater than 0.030 pounds per million Btu heat input. In addition, these sources shall be deemed to be properly operated and maintained if the %MD does not exceed 2 percent for any given calendar quarter as calculated below.

The PM monitored value subject to the 0.030 pounds per million Btu limit shall have a 5% CO2 diluent cap, or a 14 % 02 diluent cap, substituted in the emission rate calculation whenever the actual CO2 concentration is lower than 5% or whenever the actual 02 concentration is higher than 14%.

Calculations for %EE and %MD

Percent Excess Opacitv Emission (%EE) Calculation:

%EE= Total Excess Emission Time"• xlOO Total Source Operating Time ••• - Monitor Downtime

Percent Monitor Downtime (%MD) Calculation for COMS:

%MD = Total Monitor Downtime ** x 100

Total Source Operating Time •••

* Total Excess Emission Time contains any 6-minute period greater than 40% opacity including startup, shutdown, and malfunction.

** Total Monitor Downtime includes Quality Assurance (QA) activities unless exempted by regulation or defined in an agency approved QA Manual. The amount of exempt QA Time will be reported in the quarterly report as such.

***If a source operates less than 2,200 hours during any quarter, the source may calculate the ¾EE and/or %MD using all operating data for the current quarter and the preceding quarters until 2,200 hours of data are obtained. [N.C.G.S. 143-215.110]

b. The Pennittee shall use a continuous emissions monitoring system (CEMS) to monitor and record sulfur dioxide emissions. Continuous emissions monitoring and recordkeeping of sulfur dioxide emissions shall be performed as described in Paragraphs 2 and 3.1.1 through 3.1.5 of Appendix P of 40 CFR Part 51. The monitoring systems shall meet the minimum specifications described in Paragraphs 3.3 through 3.8 of

Page 24: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 01001 T56 Page 17

Appendix P of 40 CFR Part 51. The quarterly excess emissions (EE) reports required under Appendix P of 40 CPR Part 51 shall be used as an indication of good operation and maintenance of the flue gas desulfurization scrubbers. These sources shall be deemed to be properly operated and maintained if sulfur dioxide emissions do not exceed the limit in Section 2.1 A.2.b., calculated on a 24-hour basis. Compliance with the sulfur dioxide emission standard is determined by averaging hourly continuous emission monitoring system values over a 24-hour block period beginning at midnight. To compute the 24-hour block average, the average hourly values are summed, and the sum is divided by 24. A minimum of four data points, equally spaced, is required to determine a valid hour value unless the continuous emission monitoring system is installed to meet the provisions of 40 CFR Part 75. If a continuous emission monitoring system is installed to meet the provisions of 40 CFR Part 75, the minimum number of data points are determined by 40 CFR Part 75. In addition, the flue gas desulfurization scrubbers shall be deemed to be properly operated and maintained if the %MD does not exceed 2 percent for any given calendar quarter as calculated in Section 2.1 A.7.a above.

Reporting D5A NCAC 02Q .0508(±)) c. The Permittee shall submit the excess emissions and monitor downtime reports as required under Appendix

P of 40 CPR Part 51 postmarked on or before January 30 of each calendar year for the preceding three­month period between October and December, April 30 of each calendar year for the preceding three-month period between January and March, July 30 of each calendar year for the preceding three-month period between April and June, and October 30 of each calendar year for the preceding three-month period between July and September as shown below. Reporting shall be in accordance with Paragraphs 4 and 5 .1 of Appendix P of40 CFRPart 51.

1. Excess PM emissions are defined as any one-hour average greater than 0.03 powids per million Btu heat input. The quarterly report shall include the number of hours each day and the percent of operating hours during the quarter with average PM emissions recorded by the PM CEMS greater than 0.030 pounds per million Btu.

11. Excess sulfur dioxide emissions are defined as greater than the limit in Section 2.1 A.2.b. calculated on a 24-hour block average basis. Reporting shall be in accordance with Paragraphs 4 and 5.1 of Appendix P of 40 CFR Part 51.

111. All instances of deviations from the requirements of this pennit must be clearly identified.

Page 25: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pe1111it No. 01001 T56 Page 18

B. Boiler Unit 4:

Two coal/No. 2 fuel oil-fired electric utility boilers, each equipped with low-NOx burners, Mg(OH)2 fuel additive (ID Nos. ES-Unit 4A and ES-Unit 4B) and associated selective catalytic reduction systems (ID Nos. CD-SCR4a and CD-SCR4b) installed in series with eight electrostatic precipitators (ID Nos. CD-ESP4a through CD-ESP4h) in series with a wet scrubber (ID No. CD-FGD4), and sorbent injection system (ID No. CD-INJ-Sorb4)

The following table provides a summarv of limits and standards for the emission source(s) described above:

Regulated Limits/Standards Applicable Regulation Pollutant

sulfur dioxide See Section 2.1 B.l.b ISA NCAC 02D .0524

( 40 CFR Part 60 Subpart D)

0.547 pounds per million Btu heat input 15ANCAC 02D .050l(c)

Phase II Acid Rain Permit Requirements (see Section 2.4) ISA NCAC 02Q .0402 ( 40 CPR Part 72)

(Federally Enforceable Only) 40 CFR Part 97,

Cross State Air Pollution Rule Requirements Subpart CCCCC

(see Section 2,2 B.1)

nitrogen oxides See Section 2.1 B.1.b 15A NCAC 02D .0524

( 40 CFR Part 60 Subpart D)

Phase II Acid Rain Permit Requirements (see Section 2.4) 1 SA NCAC 02Q .0402 ( 40 CFR Part 72)

(Federally Enforceable Only) 40 CFR Part 97,

Cross State Air Pollution Rule Requirements Subparts AAAAA and BBBBB

(see Section 2.2 B.I)

particulate 0.03 pound per million Btu heat input

15A NCAC 02D .0524 matter ( 40 CFR Part 60 Subpart D)

Hazardous Air See Section 2.2 B.2. 15ANCAC 02D .1111

Pollutants ( 40 CFR. 63, Subpart UUUUU)

various See Section 2.1 B.3. 15A NCAC 02D .0530(u)

[Projected Actual Emissions]

1. 15A NCAC 02D .0524: NEW SOURCE PERFORMANCE STANDARDS (40 CFRPART 60 SUBPART D)

a. The Perm:ittee shall comply with all applicable provisions, including the notification, testing, reporting, recordkeeping, and monitoring requirements in accordance with 15A NCAC 02D .0524, "New Source Performance Standards (NSPS) as promulgated in 40 CPR Part 60, Subpart D "Standards of Perfonnance for Fossil-Fuel-Fired Steam Generators", including Subpart A "General Provisions."

b. The following emission limits shall not be exceeded:

POLLUTANT EMISSION LIMIT (pounds per million Btu)

sulfur dioxide y(O.SO) + z(l.2) [40 CPR 60.43(a), (b)] (SO:i) y+z

Page 26: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Page 19

POLLUTANT

nitrogen oxides ( expressed as N02)

particulates

EMISSION LIMIT (pounds per million Btu)

y(0.30) + z(0.70) [§60.44(a), (b)J y+z

0.03 [§60.42(c), §60.42Da(a)]

y = percentage of total heat input derived from liquid fossil fuel z = percentage of total heat input derived from solid fossil fuel

c. Any use of the electrostatic precipitator high voltage control Energy Management System (EMS) feature requires a revision to this permit.

Testing [15A NCAC 02Q .0508(£)] d. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limits given in Section 2.1 B.1. b above, the Permittee shall be deemed in noncompliance with 15A NCAC 02D .0524.

e. Once per calendar year, the Permittee shall conduct a stack test for particulate matter in accordance with either Method 5 at a sample temperature of 320° ± 25° Fas described in §63.lOOlO(i)(l) or Method SB of Appendix A of 40 CFR Part 60. In the event that a boiler exceeds 80 percent of its particulate emission limit during the stack test, the Permittee shall schedule and conduct another stack test within 6 months. Upon demonstration that the source is operating under 80 percent of its particulate limit, as shown by three consecutive semiannual stack tests, the source may resume annual stack tests. If the result of any stack test is greater than the limit given in Section 2.1 B.l.b above, the Permittee shall be deemed in noncompliance with 15A NCAC 02D .0524.

Monitoring/Recordkeeping rt5A NCAC 02Q .0508(t)] f. 1. The Pennittee shall install, maintain, and operate a PM CEMS. [40 CFR 60.42(c)]

ii. The Pennittee shall install, maintain, and operate a CEMS for measuring sulfur dioxide emissions, nitrogen oxide emissions, and either oxygen or carbon dioxide, as per the requirements of 40 CFR Part 75. [§60.45(a)]

g. Compliance with S02 and NOx emission limits of Section 2.1 B.l.b above, shall be determined by averaging hourly continuous emission monitoring system values over any three-hour (rolling) period. The three-hour average shall be the arithmetic average of three contiguous one-hour periods of sulfur dioxide or nitrogen oxides as measured by the continuous emission monitoring system. Missing data shall not be filled nor shall the data be bias adjusted in accordance with 40 CFR Part 75. The minimum number of data points, equally spaced, required to determine a valid hour value shall be determined by 40 CFR Part 75. If any three-hour average exceeds emission limits of Section 2.1 B.2.b above ( except during periods of startup, shutdown and malfunction) or records are not maintained, the Permittee shall be deemed in noncompliance with 15A NCAC 02D .0524. [§60.8 and §60.45J

h. Compliance with the particulate limit in Section 2.1 B.l.b shall be determined using the PM CEMS.

1. Each PM CEMS shall be installed, evaluated, operated, and maintained according to the requirements in §60.49Da(v). For affected facilities using a PM CEMS, a COMS is not required. [§60.45(b)(5), §60.48Da(p )(2)]

ii. When demonstrating compliance, the PM emission rate shall be determined based on a 24-hour daily (block) average of the hourly arithmetic average emissions concentrations using the CEMS outlet data each boiler operating day, except for data obtained during startup, shutdown, and malfunction. Averages are only calculated for boiler operating days that have valid data for at least 18 hours of unit

Page 27: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Page 20

operation during which the standard applies. Instead, all of the valid hourly emission rates of the operating day( s) not meeting the minimum 1 8 hours valid data daily average requirement are averaged with all of the valid hourly emission rates of the next boiler operating day with 18 hours or more of valid PM CEMS data to determine compliance. The 24-hour block arithmetic average emission concentration shall be calculated using EPA Reference Method 19 of Appendix A of 40 CFR Part 60, section 4.l. [§60.48Da(f), (p)(4)]

iii. At a minimum, valid PM CEMS hourly averages shall be obtained for 75 percent of all operating hours on a 30-day rolling average basis. Valid PM CEMS hourly averages shall be obtained for 90 percent of all operating hours on a 30-day rolling average basis. At least two data points per hour shall be used to calculate each 1-hour arithmetic average. [§60.48Da(p)(5)

iv. The 1-hour arithmetic averages of PM CEMS data shall be expressed in pounds per million Btu and shall be used to calculate the boiler operating day daily arithmetic average emission concentrations. The 1-hour arithmetic averages shall be calculated using the data points required under §60.13( e)(2) of Subpart A of 40 CFR Part 60. [§60.48Da(p)(6)]

v. All valid PM CEMS data shall be used in calculating average emission concentrations even if the minimum CEMS data requirements of paragraph iii above are not met. [§60.48Da(p)(7)]

vi. When PM emissions data are not obtained because of PM CEMS breakdowns, repairs, calibration checks, and zero and span adjustments, emissions data shall be obtained by using other monitoring systems as approved by the DAQ or EPA Reference Method 19 of Appendix A of 40 CFR Part 60 to provide, as necessary, valid emissions data for a minimum of 90 percent of all operating hours per 30-day rolling average.

If the results of the 24-hour daily arithmetic average PM CEMS concentration exceeds the limit in.Section 2.1 B.l.b or any of the above requirements are not met, the Permittee shall be deemed in noncompliance with 15A NCAC 02D .0524.

Reporting rt SA NCAC 02Q .0508(£)] 1. The Permittee shall submit excess emissions and monitoring system performance reports for sulfur dioxide,

nitrogen oxide and PM. The reports shall be postmarked by the 30th day following the end of each calendar year quarter and shall include, at a minimum, the information required in 40 CFR 60.7(c), as follows:

i. Sulfur Dioxide - Report all three-hour periods of excess emissions (pounds per million Btu) dw-ing the reporting period including periods exempted during startup, shutdown and malfunction. Monitor availability values (as calculated for 40 CFR Part 75) for the last hour of the reporting period shall be included.

11. Nitrogen Oxides - Report all three-hour periods of excess emissions (pounds per million Btu) during the reporting period including periods exempted during startup, shutdown and malfunction. Monitor availability values (as calculated for 40 CFR Part 75) for the last hour of the reporting period shall be included.

lll. PM-

(A) Report all 24-hour daily (block) average excess emissions (pounds per million Btu) using the PM CEMS outlet data, including periods exempted during startup, shutdown, and malfunction;

(B) Within 15 days of a written request, report all PM CEMS hourly averages (in written or electronic form) to show, at a minimum, that valid PM CEMS hourly averages have been obtained for 90 percent (only 75 percent is required prior to January 1, 2012) of all operating hours on a 30-day

Page 28: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Page 21

rolling average basis; and

J· The results of any stack test shall be reported within 30 days, and the test report shall be submitted within 60 days after the test.

k. All instances of deviations from the requirements of this permit must be clearly identified.

2. ISA NCAC 02D .0S0l(c): COMPLIANCE Wim EMISSION CONTROL STANDARDS

a. In addition to any control or manner of operation necessary to meet emission standards in 15A NCAC 02D .0500, any source of air pollution shall be operated with such control or in such manner that the source shall not cause the ambient air quality standards of 15A NCAC 02D .0400 to be exceeded at any point beyond the premises on which the source is located. When controls more stringent than named in the applicable emission standards in 15A NCAC 02D .0500 are required to prevent violation of the ambient air quality standards or are required to create an offset, the permit shall contain a condition requiring these controls.

b. In order to comply with the NAAQS for sulfur dioxide3, emissions of sulfur dioxide from these sources shall not exceed 0.547 pounds per million Btu heat input, in accordance with the modeling analysis received May 16, 2007. Sulfur dioxide formed by the combustion of sulfur in fuels, wastes, ores, and other substances shall be included when determining compliance with this standard.

Testing (15A NCAC 02Q .0508(f)] c. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limits given in Section 2.1 B.2.b above, the Permittee shall be deemed in noncompliance with 15A NCAC 02D . 0501 ( c).

Monitoring/Recordkeeping [15A NCAC 02Q .0508(f) and 02D .0608] d. The Pemrittee shall ensure compliance with 15A NCAC 02D .050l(c) by determining sulfur dioxide

emissions in pounds per million Btu using continuous emissions monitoring (CEM) systems meeting the requirements of 40 CFR Part 75 except that unbiased values may be used (missing data shall be filled in accordance with 40 CFR Part 75). Compliance with sulfur dioxide emission standards shall be determined by averaging hourly continuous emission monitoring system values over a 24-hour block period beginning at midnight. To compute the 24-hour block average, the average hourly values (missing data shall be filled in accordance with 40 CFR Part 75) shall be summed, and the sum shall be divided by 24. The minimum number of data points, equally spaced, required to determine a valid hour value shall be determined by 40 CFR Part 75. If any 24-hour block average exceeds the limits given in Section 2 .1 B.2.b above or records are not maintained, the Permittee shall be deemed in noncompliance with ISA NCAC 02D .0501(c).

Reporting [15A NCAC 02Q .0508(f)] e. The Permittee shall submit the continuous emissions monitoring data showing the 24-hour daily block

values in pounds per million Btu for each 24-hour daily block averaging period during the reporting period postmarked on or before January 30 of each calendar year for the preceding three-month period between October and December, April 30 of each calendar year for the preceding three-month period between January and March, July 30 of each calendar year for the preceding three-month period between April and June, and October 30 of each calendar year for the preceding three-month period between July and September. All instances of deviations from the requirements of this permit must be clearly identified.

f. CEMs Monitor Availability -The Pennittee shall submit sulfur dioxide and nitrogen oxides CEM systems monitor downtime reports, including monitor availability values (as calculated for 40 CFR Part 75) for the last hour of the reporting period, postmarked on or before January 30 of each calendar year for the preceding three-month period between October and December, April 30 of each calendar year for the preceding three-

3 61 Fed. Reg. 25566 (May 22, 1996)

Page 29: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 01001 T56 Page 22

month period between January and March, July 30 of each calendar year for the preceding three-month period between April and June, and October 30 of each calendar year for the preceding three-month period between July and September.

3. 15A NCAC 02D .0530(u): PREVENTION OF SIGNIFICANT DETERIORATION (Use of Projected Actual Emissions)

a. The Perrnittee has used projected actual emissions (submitted in the .18B permit application), as below, to avoid applicability of prevention of significant deterioration requirements for a project consisting of replacement of existing low NOx burners for coal firing on Unit 4 boilers (ID Nos. ES-Unit 4A and ES­Unit 4B).

Projected Actual Pollutant Emissions*

( tons per year)

PM 28.6

PMro 44.7

PM2_5 39.0

S02 390.4**

NOx 427.0**

voe 6.6

co 428.1

Lead 0.0082

Sulfuric Acid Mist 25.1

GHGasC02e 560,565.9

* The projected actual emissions are not enforceable limitations. Maximum annualized value for period 2019 through 2023.

** Maximum annualized value, Fuel and Operations Forecast Model output for period 2019 through 2023.

In order to verify the assumptions used in the projected actual emissions calculations, the Pennittee shall comply with the testing, record keeping and reporting requirements in Section 2.1 B.3.b. through c. below.

Testing f15A NCAC 02Q .0508(t)] b. No testing shall be required.

Monitoring/Record.keeping [15A NCAC 02D .0530(u), 15A NCAC 02Q .0508(f)] c. In order to verify the assumptions used in the projected actual emissions calculations, the Permittee shall

maintain records of annual emissions related to the Low-NOx burner replacement project. The records shall be maintained for five years following the completion of this project.

1. The replacement project was completed in CY2018.

11. The last year ofrecordkeeping will be CY2023.

Reporting [15A NCAC 02D .0530(u), 15A NCAC 02Q .0508(f)] c. The Permittee shall submit a report of the records required by Paragraph c. above. The report shall be

postmarked within 60 days after the end of each year where recordkeeping was required by Paragraph c.

Page 30: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. OJ 001 T56 Page 23

C.

• Unit 1 dry flyash pneumatic tnnsfer system including surge bin and filter separators (ID No. ES­F A Handling 1) and associated bagfilters (ID Nos. CD-BF14, CD-FS-lA and CD-FS-lB)

• Unit 3 dry flyash pneumatic transfer systems and filter separators (ID Nos. ES-FA Handling 3A and ES-FA Handling 3B), and associated bagfilters ID Nos. CD-FS-3A and CD-FS-3B)

• Unit No. 3 dry flyash conveying system surge/transfer tank (ID No. ES-Surge Bin 3), and associated bagfilter (ID No. CD-BF15)

• Unit 4 dry flyash pneumatic transfer systems and filter separators (ID Nos. ES-FA Handling 4A, ES-FA Handling 4B and ES-FA Handling 4C), and associated bagfilters CD-FS-4A, CD-FS-4B and CD-FS-4C)

• three flyash conveying system storage and handling silos (ID Nos. ES-FA Silo 1, ES-FA Silo 2, and ES-FA Silo 4), and associated bagfilters (ID Nos. CD-BFl, CD-BF2, CD-BF3, CD-BF4, CD­BF7, and Cl).. BF8)

• one flyash conveying system storage and handling silo (ID No. ES-FA Silo 5) and associated bagfilters (ID Nos. Cl)..BF9 and CD-BFl0)

• electrostatic flyash separation system consisting of one mineral-tich product load-out silo (ID No. ES-S-3L) and two electrostatic flyash separation and conveying systems (ID Nos. ES-EFSSl and ES-EFSS2), and associated bagfilters (ID Nos. CD-BF23 and CD-BF24)

• stationary vacuum system for housekeeping (ID No. ES-SVSl) and integral bagftlter (ID No. CD-BF26)

• flyash conveying system storage and handling silo (ID No. ES-FA Silo 3) and one mineral-rich flyash loadout system (ID No. ES-S-3L2), and associated bagfilters (ID Nos. CD-BFS and CD­BF6)

Note: Operation of each existing Units 1, 3 and 4 dry flyash conveying system may continue until new systems are fully operational.

The following ta e provi bl de s asummary o fr 1mits and standards for e emission source(s) describe a o th d b ve:

Regulated Limits/Standards

Applicable Pollutant Regulation

particulate E = 4.10 X p 0·67 for P _::; 30 tons/hr, or 15A NCAC 02D .0515 matter E = 55.0 x P 0-11 - 40for P > 30 tons/hr

where: E = allowable emission rate in pounds per hour P = process weight rate in tons per hour

visible 20 percent opacity 15ANCAC 02D .0521 emissions

toxic air See Section 2.2 A.1 15A NCAC 02D .1100 pollutants State-only requirement

Page 31: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Page 24

1. 15A NCAC 02D .0515: PARTICULATES FROM MISCELLANEOUS INDUSTRIAL PROCESSES

a. Emissions of particulate matter from these sources (ID Nos. ES-FA Handling I, ES-FA Handling 3A through ES-FA Handling 3C, ES-FA Handling 4A through ES-FA Handling 4C, ES- FA Silot through ES-FA Silo5, ES-S-3L, ES-EFSSl, ES-EFSS2, ES-SVSl, and ES-S-3Ll) shall not exceed an allowable emission rate as calculated by the following equation:

for P .:5 30 tons/h for P > 30 tons/hr

E = 4.10 x P 0·67 or E = 55.0 X p O.ll - 40

where: E = allowable emission rate in pounds per hour P = process weight in tons per hour

Liquid and gaseous fuels and combustion air are not considered as part of the process weight.

Testing [15A NCAC 02Q .0508(f)] b. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limit given in Section 2.1 C.1.a. above, the Pennittee shall be deemed in noncompliance with 15A NCAC 02D .0515.

Monitoring/Recordkeeping DSA NCAC 02Q .0508(f)] c. Particulate matter emissions from the Unit 1 dry fly ash pneumatic transfer system including surge bin and

filter separators (ID No. ES-FA Handling 1), Unit 3 dry fly ash pneumatic transfer systems and filter separators (ID Nos. ES-FA Handling 3A and ES-FA Handling 3B), Unit No. 3 dry flyash conveying system surge/transfer tank (ID No. ES-Surge Bin 3), Unit 4 dry fly ash pneumatic transfer systems and filter separators (ID Nos. ES-FA Handling 4A, ES-FA Handling 4B and ES~FA Handling 4C), three flyash conveying system storage and handling silos (ID Nos. ES-FA Silo 1, ES-FA Silo 2, and ES-FA Silo 4), one flyash conveying system storage and handling silo (ID No. ES-FA Silo 5), one electrostatic flyash separation system consisting of one mineral-rich product load-out silo (1D No. ES-S-3L) and two electrostatic flyash separation and conveying systems (ID No. ES-EFSSl and ES-EFSS2), one stationary vacuum system for housekeeping (ID Nos. ES-SVSl), one flyash conveying system storage and handling silo (ID No. ES-FA Silo 3), and one mineral-rich flyash loadout system (ID No, ES-S-3L2) shall be controlled by the bagfilters (ID Nos. CD-BF14, CD-FS-1A, CD-FS-lB, CD-FS-JA, CD-FS-3B, CD­BF15, CD-FS-4A, CD-FS-4B, CD-FS-4C, CD-BFl through CD-BFI0, CD-BF23, CD-BF24 and CD­BF26), as described above. To ensure that optimum control efficiency is maintained, the Permittee shall perform inspections and maintenance as recommended by the manufacturer implemented in the plant's Work Management System. In addition to the manufacturer's inspection and maintenance recommendations, or if there are no manufacturer's inspection and maintenance recommendations, as a minimum, the inspection and maintenance requirement shall include the following:

1. a monthly visual inspection of the system ductwork and material collection unit for leaks; and

n. an annual (for each 12-month period following the initial inspection) internal inspection of the bagfilter's structural integrity.

The Permittee shall be deemed in noncompliance with 15A NCAC 02D .0515 if the ductwork and bagfilters are not inspected and maintained.

d. The results of inspection and maintenance shall be maintained in a logbook (written or electronic format) on-site and made available to an authorized representative upon request. The logbook shall record the following:

i. the date and time of each recorded action;

Page 32: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pcnnit No. 01001 T56 Page 25

ii. the results of each inspection;

iii. the results of any maintenance performed on the bagfilters; and

1v. any variance from manufacturer's recommendations, if any, and corrections made.

The Permittee shall be deemed in noncompliance with 15A NCAC 02D .0515 if these records are not maintained.

Reporting r15A NCAC 02Q .0508(±)] e. The Permittee shall submit the results of any maintenance performed on the bagfilters within 30 days of a

written request by the DAQ.

f. The Permittee shall submit a summary report of the monitoring and record.keeping activities in Paragraphs c. and d. above postmarked on or before January 30 of each calendar year for the preceding six-month period between July and December and July 30 of each calendar year for the preceding six-month period between January and June. All instances of deviations from the requirements of this permit must be clearly identified.

2. ISA NCAC 02D .0521: CONTROL OF VISIBLE EMISSIONS

a. Visible emissions from these sources (ID Nos. ES-FA Handling 1, ES-FA Handling 3A through ES-FA Handling 3B, ES-Surge Bin 3, ES-FA Handling 4A through ES-FA Handling 4C, ES-FA Silol through ES-FA SiloS, ES-S-3L, ES-EFSSl, ES-EFSS2, ES-SVSl, and ES-S-3L2) shall not be more than 20 percent opacity (except during startups, shutdowns, and malfunctions) when averaged over a six­minute period. However, six-minute averaging periods may exceed 20 percent not more than once in any hour and not more than four times in any 24-hour period. In no event shall the six-minute average exceed 87 percent opacity.

Testing (15A NCAC 02Q .0508(f)] b. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limit given in Section 2.1 C.2.a above, the Permittee shall be deemed in noncompliance with 15A NCAC 02D .0521.

Monitoring [15A NCAC 02Q .0508(f)] c. i. To ensure compliance, once a month the Pennittee shall observe the emission points of these sources

(ID Nos. ES-FA Handling 3A through ES-FA Handling 3B, ES-Surge Bin 3, ES-FA Handling 4A through ES-FA Handling 4C, ES-FA Silol through ES-FA Silo5, ES-S-3L, ES-EFSSl, ES-EFSS2, ES-SVSl, and ES-S-3L2) for any visible emissions above normal. The monthly observation must be made for each month of the calendar year period to ensure compliance with this requirement. The Permittee shall establish "normal" for these source in the first 30 days following the of beginning operation. If visible emissions from these sources are observed to be above normal, the Pennittee shall either:

(A) immediately shutdown the source and repair the malfunction, or

(B) demonstrate that the percent opacity from the emission points of the emission source in accordance with 15 A NCAC 02D .2610 (Method 9) for 12 minutes is below the limit given in Section 2.1 C .2.a above.

11. The Pennittee shall be deemed to be in noncompliance with 15A NCAC 02D .0521 if:

(A) the source is not immediately shutdown and repaired per c.i.(A) above;

Page 33: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001T56 Page 26

(B) the demonstration in c.i.(B) above cannot be made;

(C) the monthly observations are not conducted per c.i above; or

(D) "normal" is not established for per c.i above.

Record.keeping [15A NCAC 02Q .0508(f)] d. The results of the monitoring shall be maintained in a logbook (written or electronic format) on-site and

made available to an authorized representative upon request. The logbook shall record the following:

i. the date and time of each recorded action;

11. the results of each observation and/or test noting those sources with emissions that were observed to be in noncompliance along with any corrective actions taken to reduce visible emissions; and

iii. the results of any corrective actions performed.

The Permittee shall be deemed in noncompliance with 15A NCAC 02D .0521 if these records are not maintained.

Reporting rI5A NCAC 02Q .0508(f)] e. The Permittee shall submit a summary report of the monitoring and recordkeeping in Paragraphs c. and d.

above postmarked on or before January 30 of each calendar year for the preceding six-month period between July and December and July 30 of each calendar year for the preceding six-month period between January and June. All instances of deviations from the requirements of this permit must be clearly identified.

3. 15A NCAC 02Q .0504: OPTION FOR OBTAINING CONSTRUCTION AND OPERATION PERMIT

Reporting rl5A NCAC 02Q .0508(f)] a. The Permittee shall notify the Regional Office in writing of the date of beginning operation of these sources

(ID Nos. ID Nos. ES-FA Handling 1, ES-FA Handling 3A, ES-FA Handling 3B, ES-Surge Bin 3, ES­FA Handling 4A, ES-FA Handling 4B, ES-FA Handling 4C and ES-FA Silo 5) and associated air pollution control devices (ID Nos. CD-FS-1A, CD-FS-lB, CD-FS-3A, CD-FS-3B, CD-FS-3C, CD-FS-4A, CD-FS-4B, CD-FS-4C, CD-BF9 and CD-BFlO), postmarked on or before 30 days after such date.

Page 34: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pern1it No.01001 T56 Page 27

D.

• No. 1 flyash conveying system storage and handling silo, and load-out stations (ID No. ES-S-1) and associated wet flyash conditioners (ID Nos. CD-\VSl and CD-WS2)

• No. 4 flyash conveying system storage and handling silo, and load-out stations (ID No. ES-S-4) and associated wet flyash conditioners (ID Nos. CD-WS3, CD-WS4 and CD-WS5)

• No. 5 flyash conveying system storage and handling silo, and load-out station (ID No. ES-S-5) and associated flyash mixer conditioners (ID Nos. CD-WS6 and CD-WS7)

Note: Operation of the No. 5 flyash conveying system may continue until the new system is fully operational.

The following table orovides a summary oflimits and standards for the emission source(s) described abo ve: Regulated

Limits/Standards Applicable Regulation Pollutant

particulate E = 4.10 X p 0.67 for P ~ 30 tons/hr, or 15A NCAC 02D .0515 matter E = 55.0 x P o.1i - 40for P > 30 tons/hr

where: E = allowable emission rate in powids per hour

P = process weight rate in tons per hour

visible 20 percent opacity 15A NCAC 02D .0521 emissions

toxic air See Section 2.2 A.1 15ANCAC 02D .1100 pollutants State-only requirement

1. 15A NCAC 02D .0515: PARTICULATES FROM MISCELLANEOUS INDUSTRIAL PROCESSES

a. Emissions of particulate matter from these sources (ID Nos. ES-S-1, ES-S-4, and ES-S-5) shall not exceed an allowable emission rate as calculated by the following equation:

for P ~ 30 tons/h for P > 30 tons/hr

E == 4.10 x p o.61 or E = 55.0 X p O.ll - 40

where: E = allowable emission rate in pounds per hour P = process weight in tons per hour

Liquid and gaseous fuels and combustion air are not considered as part of the process weight.

Testing rl5A NCAC 02Q .0508(f)J b. lf emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limit given in Section 2.1 D.l.a. above, the Pennittee shall be deemed in noncompliance with 15A NCAC 02D . 0515.

Monitoring/Recordkeeping/Reporting r 15A NCAC 02Q .0508(£)] c. No monitoring/recordkeeping!reporting is required for emissions from these sources.

Page 35: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Penni! No. 0100] T56 Page 28

2. 15A NCAC 02D .0521: CONTROL OF VISIBLE EMISSIONS

a. Visible emissions from these sources (ID Nos. ES-S-1, ES-S-4, and ES-S-5) shall not be more than 20 percent opacity (except during startups, shutdowns, and malfunctions) when averaged over a six-minute period. However, six-minute averaging periods may exceed 20 percent not more than once in any hour and not more than four times in any 24-hour period. In no event shall the six-minute average exceed 87 percent opacity.

Testing (15A NCAC 02Q .0508(f)] b. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limit given in Section 2.1 D.2.a above, the Pennittee shall be deemed in noncompliance with 15A NCAC 02D .0521.

Monitoring [15A NCAC 02Q .0508(t)J c. 1. To ensure compliance, once a month the Permittee shall observe the emission points of these sources

(ID Nos. ES-S-1, ES-S-4, and ES-S-5) for any visible emissions above normal. The monthly observation must be made for each month of the calendar year period to ensure compliance with this requirement. The Pennittee shall establish "normal" for these source in the first 30 days following the of beginning operation. If visible emissions from these sources are observed to be above normal, the Permittee shall either:

(A) immediately shutdown the source and repair the malfunction, or

(B) demonstrate that the percent opacity from the emission points of the emission source in accordance with 15A NCAC 02D .2610 (Method 9) for 12 minutes is below the limit given in Section 2.1 C.2.a above.

11. The Permittee shall be deemed to be in noncompliance with 15A NCAC 02D .0521 if:

(A) the source is not immediately shutdown and repaired per c.i.(A) above;

(B) the demonstration in c.i.(B) above cannot be made;

(C) the monthly observations are not conducted per c.i above; or

(D) ''normal" is not established for per c.i above.

Recordkeeping [15A NCAC 02Q .0508(t)] d. The results of the monitoring shall be maintained in a logbook (written or electronic format) on-site and

made available to an authorized representative upon request. The logbook shall record the following:

1. the date and time of each recorded action;

11. the results of each observation and/or test noting those sources with emissions that were observed to be in noncompliance along with any corrective actions taken to reduce visible emissions; and

m. the results of any corrective actions performed.

The Permittee shall be deemed in noncompliance with 15A NCAC 02D .0521 if these records are not maintained.

Page 36: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Penn it No. 01001 T56 Page 29

Reporting (15A NCAC 02Q .0508(f)] e. The Permittee shall submit a summary report of the monitoring and recordkeeping in Paragraphs c. and d.

above postmarked on or before January 30 of each calendar year for the preceding six-month period between July and December and July 30 of each calendar year for the preceding six-month period between January and June. All instances of deviations from the requirements of this permit must be clearly identified.

3. 15A NCAC 02Q .0504: OPTION FOR OBTAINING CONSTRUCTION AND OPERATION PERMIT

Reporting P5A NCAC 02Q .0508(f)] a. The Permittee shall notify the Regional Office in writing of the date of beginning operation of this source

(ID No. ID No. ES-S-5) and associated air pollution control devices (ID Nos. CD-WS6 and CD-WS7), postmarked on or before 30 days after such date.

Page 37: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Qualify Permit No. 01001T56 Page 30

E.

• Six coal storage silos {ID Nos. ES-Coal Silo 1 through ES-Coal Silo 6) • Four coal conveyors (ID Nos. ES-37 A, ES-37B, ES-39A, and ES-39B)

The followin table orovides a • "" " '1.IY oflimits and standards for the emission source(s) described above:

Regulated Limits/Standards Applicable Regulation Pollutant

particulate E = 4.10 X p 0·67 for P :'S 30 tons/hr, or 15A NCAC 02D .0515 matter E == 55.0 x P OJI - 40for P > 30 tons/hr

where: E = allowable emission rate in pounds per hour P = process weight rate in tons per hour

visible 20 percent opacity 15A NCAC 02D .0524 emissions ( 40 CPR Part 60 Subpart Y)

toxic air See Section 2.2 A. l 15A NCAC 02D .1100 pollutants State-only requirement

1. 15A NCAC 02D .0515: PARTICULATES FROM MISCELLANEOUS INDUSTRIAL PROCESSES

a. Emissions of particulate matter from these sources (ID Nos. ES-Coal Silo 1 through ES-Coal Silo 6, ES-37 A, ES-37B, ES-39A, and ES-39B) shall not exceed an allowable emission rate as calculated by the following equation:

for P .:5 30 tons/h for P > 30 tons/hr

E = 4.10 x P 0•67 or E = 55.0 X p O.ll - 40

where: E = allowable emission rate in pounds per hour P = process weight in tons per hour

Liquid and gaseous fuels and combustion air are not considered as part of the process weight.

Testing (15A NCAC 02Q .0508(f)] b. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limit given in Section 2.1 E.1.a. above, the Pennittee shall be deemed in noncompliance with 15A NCAC 02D .0515.

Monitoring/Recordkeeping/Reporting f15A NCAC 02Q .0508(f)] c. The Pennittee shall maintain production records such that the process rates "P" in tons per hour, as specified

by the formulas contained above can be derived, and shall make these records available to a DAQ authorized representative upon request. The Permittee shall be deemed in noncompliance with 15A NCAC 02D . 0515 if the production records are not maintained.

d. No reporting is required for particulate emissions from these sources (ID Nos. ES-Coal Silo 1 through ES-Coal Silo 6, ES-37A, ES-37B, ES-39A, and ES-39B).

2. 15A NCAC 02D .0524: NEW SOURCE PERFORMANCE STANDARDS (40 CFRPART 60 SUBPART Y)

a. The Permittee shall comply with all applicable provisions, including the notification, testing, reporting, recordk.eeping, and monitoring requirements in accordance with 15A NCAC 02D .0524, "New Source

Page 38: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air QualityPem1it No. 01001T56 Page 31

Performance Standards (NSPS) as promulgated in 40 CFR Part 60, Subpart Y "Standards of Performance for Coal Preparation and Processing Plants", including Subpart A "General Provisions."

b. On or after the date on which the performance test required to be conducted under 40 CFR 60.8 is completed, visible emissions shall not be 20 percent opacity or greater except during periods of startup, shutdown and malfunction.

Testing [15A NCAC 02Q .0508(£)] c. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limit given in Section 2.1 E.2.b. above, the Permittee shall be deemed in noncompliance with 15A NCAC 02D .0524.

Monitoring [15ANCAC 02Q .0508(t)] d. i. To ensure compliance, once a month the Pennittee shall observe the emission points of these sources

(ID Nos. ES-S-1, ES-S-4, and ES-S-5) for any visible emissions above normal. The monthly observation must be made for each month of the calendar year period to ensure compliance with this requirement. If visible emissions from these sources are observed to be above nonnal, the Permittee shall either:

(A) immediately shutdown the source and repair the malfunction, or

(B) demonstrate that the percent opacity from the emission points of the emission source in accordance with 15A NCAC 02D .2610 (Method 9) for 12 minutes is below the limit given in Section 2.1 E.2.a above.

n. The Permittee shall be deemed to be in noncompliance with 15A NCAC 02D .0521 if;

(A) the source is not immediately shutdown and repaired per d.i.(A) above;

(B) the demonstration in d.i.(B) above cannot be made;

(C) the monthly observations are not conducted per d.i above; or

Recordkeeping [15A NCAC 02Q .0508(£)] e. The results of the monitoring shall be maintained in a logbook (written or electronic format) on-site and

made available to an authorized representative upon request. The logbook shall record the following:

1. the date and time of each recorded action;

11. the results of each observation and/or test noting those sources with emissions that were observed to be in noncompliance along with any corrective actions taken to reduce visible emissions; and

iii. the results of any corrective actions performed.

The Permittee shall be deemed in noncompliance with ISA NCAC 02D .0524 if these records are not maintained.

Reporting [15A NCAC 02Q .0508(f)] f. The Permittee shall submit a summary report of the monitoring and recordkeeping in Paragraphs c. and d.

above postmarked on or before January 30 of each calendar year for the preceding six-month period between July and December and July 30 of each calendar year for the preceding six-month period between January and June. All instances of deviations from the requirements of this permit must be clearly identified.

Page 39: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pem1it No. 01001 T56 Page 32

F. coal unloading hopper (ID No. ES-Coal Hopper) with wet suppression and two coal conveyors (ID Nos. ES-Coal Convey 1 and ES-Coal Convey 2)

h t: 1 T e ol owing table provides a summary of limits and standards for the emission source(s) described above

Regulated Limits/Standards Applicable Regulation Pollutant

visible emissions 20 percent opacity 15A NCAC 02D .0524 ( 40 CFR Part 60 Subpart Y)

toxic air pollutants See Section 2.2 A.1

15A NCAC 02D .1100 State-only requirement

1. 15A NCAC 02D .0524: NEW SOURCE PERFORMANCE STANDARDS (40 CFRPART 60 SUBPART Y)

a. The Permittee shall comply with all applicable provisions, including the notification, testing, reporting, recordkeeping, and monitoring requirements in accordance with 15A NCAC 02D .0524, "New Source Performance Standards (NSPS) as promulgated in 40 CFR Part 60, Subpart Y "Standards of Performance for Coal Preparation and Processing Plants", including Subpart A "General Provisions."

b. Visible emissions from these sources (ID No. ES-Coal Hopper, ES-Coal Convey 1, and ES-Coal Convey 2) shall not be 20 percent opacity or greater.

Testing [15A NCAC 02Q .0508(f)] c. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limits given in Paragraph b. above, the Permittee shall be deemed in noncompliance with 1 SA NCAC 02D .0524.

Monitoring/Recordkeeping/Reporting (15A NCAC 02Q .0508(f)] d. No monitoring/recordkeeping/reporting is required for visible emissions from these sources (ID No. ES­

Coal Bopper, ES-Coal Convey 1, and ES-Coal Convey 2).

Page 40: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit Ko. 01001 T56 Page 33

G. limestone rail unloading station (ID No. LS Rail) with wet suppression

Th fi 11 e o owmg ta bl .d e DfOVI es a summary o rnuts an fr · d Stan or e emission source s escn e a o <lards f. th ( ) d 'b d b ve:

Regulated Limits/Standards Applicable Regulation Pollutant

particulate matter ambient air quality standards 15A NCAC 02D ,0510

visible emissions 20 percent opacity 15A NCAC 02D .0521

toxic air See Section 2.2 A.I 15A NCAC 02D .1100 pollutants State-only requirement

1. 15A NCAC 02D .0510: PARTICULATES FROM SAND, GRAVEL, OR CRUSHED STONE OPERATIONS

a. The Permittee shall not cause, allow, or pennit any material to be produced, handled, transported or stockpiled without talcing measures to reduce to a minimum any particulate matter from becoming airborne to prevent exceeding the ambient air quality standards beyond the property line for particulate matter, both PMlO and total suspended particulates.

b. Fugitive non-process dust emissions shall be controlled by ISA NCAC 02D .0540.

c. The Pennittee shall control emissions from conveyors, screens, and transfer points, such that the applicable opacity standards in Sections 2.1 G.2.a below are not exceeded.

Testing ~15A NCAC 02Q .0508(f)] d. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limits given in Section 2.1 G.2 below, the Permittee shall be deemed in noncompliance with 15ANCAC 02D .0510.

Monitoring [15A NCAC 02Q .0508(f)] e. The monitoring required in Section 2.1 G.2.c below shall satisfy this requirement.

2. ISA NCAC 02D .0521: CONTROL OF VISIBLE EMISSIONS

a. Visible emissions from this source (ID No. LS Rail) shall not be more than 20 percent opacity (except during startups, shutdowns, and malfunctions) when averaged over a six-minute period. However, six­minute averaging periods may exceed 20 percent not more than once in any hour and not more than four times in any 24-hour period. In no event shall the six-minute average exceed 87 percent opacity.

Testing rl5A NCAC 02Q .0508(t)] b. If emissions testing is required, the testing shall be petformed in accordance with General Condition JJ. lf

the results of this test are above the limits given in Section 2.1 G.a, the Permittee shall be deemed in noncompliance with 15A NCAC 02D .0521.

Monitoring [15A NCAC 02Q .0508(f)] c. 1. To ensure compliance, once a month the Permittee shall observe the emission points of this source

(ID No. LS Rail) for any visible emissions above normal. The monthly observation must be made for each month of the calendar year period to ensure compliance with this requirement. If visible emissions from these sources are observed to be above normal, the Permittee shall either:

(A) immediately shutdown the source and repair the malfunction, or

Page 41: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Pa<re 34

I:>

(B) demonstrate that the percent opacity from the emission points of the emission source in accordance with 15A NCAC 02D .2610 (Method 9) for 12 minutes is below the limit given in Section 2.1 G.2.a above.

11. The Pennittee shall be deemed to be in noncompliance with 15A NCAC 02D .0521 if:

(A) the source is not immediately shut down and repaired per c.i.(A) above;

(B) the demonstration in c.i.(B} above cannot be made; or

(C) the monthly observations are not conducted per c.i above;

Recordkeeping [ISA NCAC 02Q .0508(f)] d. The results of the monitoring shall be maintained in a logbook (written or electronic format) on-site and

made available to an authorized representative upon request. The logbook shall record the following:

1. the date and time of each recorded action;

11. the results of each observation and/or test noting those sources with emissions that were observed to be in noncompliance along with any corrective actions taken to reduce visible emissions; and

iii. the results of any corrective actions performed.

The Permittee shall be deemed in noncompliance with 15A NCAC 02D .0521 if these records are not maintained.

Reporting [15A NCAC 02Q .0508(f)J e. The Permittee shall submit a summary report of the monitoring and recordkeeping in Paragraphs c, and d.

above postmarked on or before January 30 of each calendar year for the preceding six-month period between July and December and July 30 of each calendar year for the preceding six-month period between January and June. All instances of deviations from the requirements of this permit must be clearly identified.

Page 42: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. OJ 001T56 Page 35

H. Limestone Handling Equipment with Fugitive Emissions:

• Two limestone unloading hoppers (ID Nos. ES-LS Unload A and ES-LS Unload B), • three limestone belt feeders (ID Nos. ES-LS Feeder 1, ES-LS Feeder 3A, and ES-LS Feeder 3B), • two limestone reclaim hoppers (ID Nos. ES-LS Reclaim A and ES-LS Reclaim B), • three limestone conveyors (ID Nos. ES-LS Convey 2, ES-LS Convey 4A [tail-end transfer only], and ES-LS

Convey 4B [tail-end transfer only]), and • three wet limestone grinders (ID Nos. ES-LS Grinder 1, ES-LS Grinder 2, and ES-LS Grinder 3)

The following table orovides a summary of limits and standards for the emission source(s) described above

Regulated Limits/Standards Applicable Regulation Pollutant

particulate matter ambient air quality standards 15A NCAC 02D .0510

visible emissions 10 percent opacity 15A NCAC 02D .0524 (40 CFR Part 60 Subpart 000)

toxic air pollutants See Section 2.2.A. l

15A NCAC 02D .1100 State-only requirement

1. 15A NCAC 02D .0510: PARTICULATES FROM SAND, GRAVEL, OR CRUSHED STONE OPERATIONS

a. The Permittee shall not cause, allow, or permit any material to be produced, handled, transported or stockpiled without taking measures to reduce to a minimum any particulate matter from becoming airborne to prevent exceeding the ambient air quality standards beyond the property line for particulate matter, both PM10 and total suspended particulates.

b. Fugitive non-process dust emissions shall be controlled by 15A NCAC 02D .0540.

c. The Permittee shall control emissions from conveyors, screens, and transfer points, such that the applicable opacity standard in Section 2.1 H.2.b below is not exceeded.

Testing (15A NCAC 02Q .0508(f)] d. If emissions testing is required, the testing shall be perfonned in accordance with General Condition JJ. If

the results of this test are above the limit given in Section 2.1 H.2.b below, the Permittee shall be deemed in noncompliance with l SA NCAC 02D .0510.

Monitoring/Recordkeeping [15A NCAC 02Q .0508(f)] e. The Permittee shall comply with the visible emission monitoring and recordkeeping requirements in

Sections 2.1 H.2.d. and e. The Permittee shall be deemed in noncompliance with 15A NCAC 02D .0510 if the Permittee does not comply with the monitoring and recordkeeping requirements.

Reporting [15A NCAC 02Q .0508(f)] f. The Permittee shall comply with the reporting requirements in Section 2.1 H.2.f.

2. 15A NCAC 02D .0524: NEW SOURCE PERFORMANCE STANDARDS (40 CFR PART 60 SUBPART 000)

a. The Pennittee shall comply with all applicable provisions, including the notification, testing, reporting, recordkeeping, and monitoring requirements contained in Environmental Management Commission Standard 15A NCAC 02D .0524 11New Source Performance Standards (NSPS) as promulgated in 40 CPR Part 60 Subpart 000 nstandards of Performance for Nonmetallic Mineral Processing Plants", including Subpart A "General Provisions."

Page 43: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 0 l 001 T56 Page 36

Emission Limitations I 40 CFR 60.672(b)] b. Fugitive visible emissions from these sources shall not be more than 10 percent opacity.

Testing [15A NCAC 02Q .0508(£)] c. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limit given in Section 2.1 H.2.b above, the Permittee shall be deemed in noncompliance with 15A NCAC 02D .0524.

Monitoring [15A NCAC 02Q .0508(f)] d. i. To ensure compliance, once a month the Permittee shall observe the emission points of these sources

(ID Nos. ES-LS Unload A and ES-LS Unload B, ES-LS Feeder 1, ES-LS Feeder 3A, and ES-LS Feeder 3B, ES-LS Reclaim A and ES-LS Reclaim B, ES-LS Convey 2, ES-LS Convey 4A, and ES-LS Convey 4B, and ES-LS Grinder 1 through ES-LS Grinder 3) for any visible emissions above normal. The monthly observation must be made for each month of the calendar year period to ensure compliance with this requirement. The Permittee shall establish "normal" for these source in the first 30 days following the of beginning operation. If visible emissions from these sources are observed to be above normal, the Permittee shall either:

(A) immediately shutdown the source and repair the malfunction, or

(B) demonstrate that the percent opacity from the emission points of the emission source in accordance with 15A NCAC 02D .2610 (Method 9) for 12 minutes is below the limit given in Section 2.1 H.2.b above.

ii, The Permittee shall be deemed to be in noncompliance with 15A NCAC 02D .0521 if:

(A) the source is not immediately shut down and repaired per d.i.(A) above;

(B) the demonstration in d.i.(B) above cannot be made;

(C) the monthly observations are not conducted per d.i above; or

(D) "normal" is not established for per d.i above.

Recordkeeping [15A NCAC 02Q .0508(t)J e. The results of the monitoring shall be maintained in a logbook (written or electronic format) on-site and

made available to an authorized representative upon request. The logbook shall record the following:

i. the date and time of each recorded action;

11. the results of each observation and/or test noting those sources with emissions that were observed to be in noncompliance along with any corrective actions taken to reduce visible emissions; and

iii. the results of any corrective actions performed.

The Permittee shall be deemed in noncompliance with 15A NCAC 02D .0524 if these records are not maintained.

Reporting [15A NCAC 02Q .0508(f)] f. The Pennittee shall submit a summary report of the monitoring and recordkeeping in Paragraphs d. and e.

above by January 30 of each calendar year for the preceding six-month period between July and December and July 30 of each calendar year for the preceding six-month period between January and June. All instances of deviations from the requirements ofthis pennit must be clearly identified.

Page 44: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Page 37

I. Limestone Handling Equipment with Stack Emissions:

• Five limestone conveyors (ID Nos. ES-LS Convey 4A [head-end transfer only], ES-LS Convey 48 [head-end transfer only], ES-LS Convey 5, ES-LS Convey 6, and ES-LS Convey 7), and three limestone silos (ID Nos. ES-LS Silo A, ES-LS Silo B, and ES-LS Silo C) with associated bagfilter (ID No. CD-LB­BF-1),

• one limestone silo (ID No. ES-LS Mayo Silo) with associated bagftlter (ID No. CD-LB-BF-2), and • one truck loading spout (ID No. ES-Truck Spout) with associated bagfilter (ID No. CD-LB-BF-3)

Th £ 11 e o owm_g ta e orov1 es a summary o t.m1ts an stan s or t e emission source s escn e a ave: bl . d fl" . d dard £ h ( ) d "b d b Regulated

Limits/Standards Applicable Regulation Pollutant

ambient air quality standards 15ANCAC 02D .0510 particulate matter

0.022 gr/dscf 15A NCAC 02D .0524 ( 40 CFR Part 60 Subpart 000)

visible ernjssions 7 percent opacity 15A NCAC 02D .0524

( 40 CFR Part 60 Subpart 000)

toxic air pollutants See Section 2.2 A. I 15A NCAC 02D .1100

State-only requirement

1. 15A NCAC 02D .0510: PARTICULATES FROM SAND, GRAVEL, OR CRUSHED STONE OPERATIONS

a. The Permittee shall not cause, allow, or permit any material to be produced, handled, transported or stockpiled without taking measures to reduce to a minimum any particulate matter from becoming airborne to prevent exceeding the ambient air quality standards beyond the property line for particulate matter, both PM 10 and total suspended particulates.

b. Fugitive non-process dust emissions shall be controlled by 15A NCAC 02D .0540.

c. The Pennittee shall control emissions from conveyors, screens, and transfer points, such that the applicable opacity standard in Section 2 .1 L2.c below is not exceeded.

Testing (15A NCAC 02Q .0508(f)] d. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. Jf

the results of this test are above the limit given in Section 2.1 I.2.b or c below, the Pennittee shall be deemed in noncompliance with 15A NCAC 02D .0510.

Monitoring/Recordkeeping [15A NCAC 02Q .0508(£)] e. The Pennittee shall comply with the monitoring and record.keeping requirements in Section 2.1 I.2.f through

j, below. The Pennittee shall be deemed in noncompliance with 15ANCAC 02D .0510 if these monitoring and recordkeeping requirements are not satisfied.

2. 15A NCAC 02D .0524: NEW SOURCE PERFORMANCE STANDARDS (40 CFRPART 60 SUBPART 000)

a. The Permittee shall comply with all applicable provisions, including the notification, testing, reporting, recordkeeping, and monitoring requirements contained in Environmental Management Commission Standard 15A NCAC 02D .0524 "New Source Performance Standards (NSPS) as promulgated in 40 CFR Part 60 Subpart 000 "Standards of Perfonnance for Nonmetallic Mineral Processing Plants", including Subpart A "General Provisions."

Page 45: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pcnnit No. 01001 T56 Page 38

Emission Limitations [40 CFR 60.672(a)] b. Emissions of particulate matter from these sources shall not exceed 0.022 grains per standard dry cubic

foot.

c. Visible emissions from these sources shall not be more than 7 percent opacity.

Testing [15A NCAC 02Q .0508(f)J d. 1. The Pennittee has completed the initial compliance demonstration (test reference numbers 2007-186ST

and 2009-157ST).

ii. If additional emissions testing is required, the testing shall be perfonned in accordance with General Condition JJ. If the results of this test are above the limits given in Section 2.1 1.2.b or c above, the Permittee shall be deemed in noncompliance with 15A NCAC 02D .0524.

Monitoring [15ANCAC 02Q .0508(f)J e. Particulate matter emissions from the five limestone conveyors (ID Nos. ES-LS Convey 4A [head-end

transfer only], ES-LS Convey 4B [head-end transfer only], ES-LS Convey 5, ES-LS Convey 6, and ES-LS Convey 7), four limestone bins silos (ID Nos. ES-LS Silo A, ES-LS Silo B, ES-LS Silo C, and ES-LS Mayo Silo), and one truck loading spout (ID No. ES-Truck Spout) shall be controlled by the bagfilters (ID No. CD-LB-BF-1, CD-LB-BF-2, and CD-LB-BF-3) as described above. To ensure that optimum control efficiency is maintained, the Permittee shall perform inspections and maintenance as recommended by the manufacturer implemented in the plant's Work Management System. In addition to the manufacturer's inspection and maintenance recommendations, or if there are no manufacturer's inspection and maintenance recommendations, as a minimum, the inspection and maintenance requirement shall include the following:

1. a monthly visual inspection of the system ductwork and material collection unit for leaks; and

ii. an annual (for each 12 month period following the initial inspection) internal inspection of the bagfilter's structural integrity.

The Permittee shall be deemed in noncompliance with 15A NCAC 02D .0524 if the ductwork and bagfilters are not inspected and maintained.

f. 1. To ensure compliance, once a month the Permittee shall observe the emission points of these sources (ID Nos. ES-LS Convey 4A [head-end transfer only], ES-LS Convey 4B [head-end transfer only], ES-LS Convey 5, ES-LS Convey 6, and ES-LS Convey 7, ES-LS Silo A, ES-LS Silo B, ES-LS Silo C, and ES-LS Mayo Silo, and ES-Truck Spout) for any visible emissions above normal. The monthly observation must be made for each month of the calendar year period to ensure compliance with this requirement. If visible emissions from these sources are observed to be above normal, the Permittee shall either:

(A) immediately shutdown the source and repair the malfunction, or

(B) demonstrate that the percent opacity from the emission points of the emission source in accordance with 15A NCAC 02D .2610 (Method 9) for 12 minutes is below the limit given in Section 2.1 I.2.c. above.

n. The Pennittee shall be deemed to be in noncompliance with 15A NCAC 02D .0524 if:

(A) the source is not immediately shut down and repaired per f.i.(A) above;

(B) the demonstration in f.i.(B) above cannot be made; or

Page 46: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Page 39

(C) the monthly observations are not conducted per f.i above.

Recordkeeping f15A NCAC 02Q .0508(t)J g. The results of inspection, maintenance, and monit01ing in Sections 2.11.2.e and f above shall be maintained

in a logbook (written or electronic format) on~site and made available to an authorized representative upon request. The logbook shall record the following:

1. the date and time of each recorded action;

ii. the results of each inspection;

iii. the results of any maintenance performed on the bagfilters;

iv. the results of any observation and/or test noting those sources with emissions that were observed to be in noncompliance along with any corrective actions taken to reduce visible emissions;

v. the results of any corrective actions performed; and

vi. any variance from manufacturer's recommendations, if any, and corrections made.

The Permittee shall be deemed in noncompliance with 15A NCAC 02D .0524 if these records are not maintained.

Reporting [15A NCAC 02Q .0508(f)] h. The Perm.ittee shall submit a summary report of the monitoring and recordkeeping in Paragraphs e through

g. above by January 30 of each calendar year for the preceding six-month period between July and December and July 30 of each calendar year for the preceding six-month period between January and June. All instances of deviations from the requirements of this permit must be clearly identified.

i. 1n addition to any other notification requirements to the Environmental Protection Agency (EPA), for the limestone conveyor (ID No. ES-LS Convey 7) with associated bagfilter (ID No. CD-LB-BF-1), limestone silo (ID No. ES-LS Mayo Silo) with associated bagfilter (ID No. CD-LB-BF-2); and truck loading spout (ID No, ES-Truck Spout) with associated bag:filter (ID No. CD-LB-BF-3), the Pennittee is required to NOTIFY the Regional Supervisor, DAQ, in WRITING, of the following:

i. the date construction (40 CFR 60.7) or reconstruction (40 CFR 60.15) of an affected facility is commenced, postmarked on or before 30 days after such date; and

ii. the actual date of initial start-up of an affected facility, postmarked within 15 days after such date.

Page 47: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 01001T56 Page 40

J.

• stationary sorbent Silo 1 for Unit 4 (ID No. ES-SORB-5) and associated bagfilter (ID No. CD­SORB-5), and Unit 4 Silo 1 pneumatic conveying equipment system (ID No. ES-SO RB-7)

• stationary sorbent Silo I for Unit 3 (ID No. ES-SORB-9) and associated bagfilter (ID No. CD­SORB-9), and Unit 3 Silo 1 pneumatic conveying equipment system (ID No. ES-SORB-11)

• stationary sorbent Silo 1 for Unit 2 (ID No. ES-SORB-13) and associated bagfilter (ID No. CD­SORB-13), and Unit 2 Silo 1 pneumatic conveying equipment system (ID No. ES-SORB-15)

• stationary sorbent Silo 1 for Unit 1 (ID No. ES-SORB-17) and associated bagfilter (ID No. CD­SORB-17), and Unit 1 Silo 1 pneumatic conveying equipment system (ID No. ES-SORB-19)

The following table provides a summary of limits and standards for the emission source(s) described above:

Regulated Limits/Standards Applicable Regulation Pollutant

particulate E = 4.10 X p 0·67 for P ~ 30 tons/hr, or 15ANCAC 02D .0515 matter E = 55.0 x P 0

·11

- 40for P > 30 tons/hr where: E = allowable emission rate in pounds per hour

P = process weight rate in tons per hour

visible emissions 20 percent opacity 15A NCAC 02D .0521

1. 15A NCAC 02D .0515: PARTICULATES FROM MISCELLANEOUS INDUSTRIAL PROCESSES

a. Emissions of particulate matter from these sources (ID Nos. ES~SORB-5, ES-SORB-7, ES-SORB-9, ES­SORB-11, ES-SORB-13, ES-SORB-15, ES-SORB-17, and ES-SORB-19) shall not exceed an allowable emission rate as calculated by the following equation:

for P s 30 tons/h for P > 30 tons/hr

E = 4.10 x P 0·67 or E = 55.0 X p O.ll - 40

where: E = allowable emission rate in pounds per hour P = process weight in tons per hour

Liquid and gaseous fuels and combustion air are not considered as part of the process weight.

Testing r15A NCAC 02Q .0508(±)] b. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limit given in Section 2.1 J. l .a above, the Permittee shall be deemed in noncompliance with 15A NCAC 02D .0515.

Monitoring [15A NCAC 02Q .0508(f)] c. Particulate matter emissions from these sources (ID Nos. ES-SORB-5, ES-SORB-7, ES-SORB-9, ES­

SORB-11, ES-SORB-13, ES-SORB~15, ES-SORB-17, and ES-SORB-19) shall be controlled by the bagfilters (ID Nos. CD-SORB-5, CD-SORB-9, CD-SORB-13, and CD-SORB-17) as described in Section 1. To ensure that optimum control efficiency is maintained, the Permittee shall perform inspections and maintenance as recommended by the manufacturer implemented in the plant's Work Management System. In addition to the manufacturer's inspection and maintenance recommendations, or if there are no

Page 48: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Qnality Pennit No. 0 I 001 T56 Page 41

manufacturer's inspection and maintenance recommendations, as a minimum, the inspection and maintenance requirement must include the following:

1. an annual (for each 12 month period following the initial inspection) internal inspection of the bagfilters' structural integrity; and

ii. a monthly visual inspection of the system ductwork, and material collection unit for leaks.

The Perrnittee shall be deemed in noncompliance with 15A NCAC 02D .0515 if the ductwork and bagfilter are not inspected and maintained.

Recordkeeping rl5A NCAC 02Q .0508(f)] d. The results of inspection and maintenance shall be maintained in a log book (written or electronic form) on

site and made available to an authorized representative upon request. The log book shall record the following:

i. the date and time of actions recorded;

ii. the results of each inspection;

iii. the results of any maintenance perfonned on the bagfilter; and

1v. any variance from manufacturer's recommendations, if any, and corrections made.

The Perrnittee shall be deemed in noncompliance with 15A NCAC 02D .0515 if these records are not maintained.

Reporting (15A NCAC 02Q .0508(f)] e. The Perrnittee shall submit the results of any maintenance performed on the bagfilter within 30 days of a

writlen request by the DAQ.

f. The Perrnittee shall submit a summary report of monitoring and recordkeeping activities in Paragraphs c. and d. above by January 30 and July 30 of each calendar year for the preceding six-month period. All instances of deviations from the requirements of this permit must be clearly identified.

2, 15A NCAC 02D .0521: CONTROL OF VISIBLE EMISSIONS

a. Visible emissions from these sources (ID Nos. ES-SORB-5, ES-SORB-7, ES-SORB-9, ES-SORB-11, ES-SORB-13, ES-SORB-15, ES-SORB-17, and ES-SORB-19) shall not be more than 20 percent opacity (except during startups, shutdowns, and malfunctions) when averaged over a six-minute period. However, six-minute averaging periods may exceed 20 percent not more than once in any hour and not more than four times in any 24-hour period. In no event shall the six-minute average exceed 87 percent opacity.

Testing {15A NCAC 02Q .0508(f)] b. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limit given in Section 2.1 J.2.a above, the Pennittee shall be deemed in noncompliance with 15A NCAC 02D .0521.

Monitoring [15A NCAC 02Q .0508(f)] c. 1. To ensure compliance, once a month the Pennittee shall observe the emission points of these sources

(ID Nos. ES-SORB-5, ES-SORB-7, ES-SORB-9, ES-SORB-11, ES-SORB-13, ES-SORB-15, ES­SORB-17, and ES-SORB-19) for any visible emissions above norm.al. The monthly observation must be made for each month of the calendar year period to ensure compliance with this requirement. The

Page 49: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 01001 T56 Page 42

Permittee shall establish "nonnal" for these source in the first 30 days following the of beginning operation. If visible emissions from these sources are observed to be above norm.al, the Permittee shall either:

(A) immediately shutdown the source and repair the malfunction, or

(B) demonstrate that the percent opacity from the emission points of the emission source in accordance with ISA NCAC 02D .2610 (Method 9) for 12 minutes is below the limit given in Section 2.1 J.2.a above.

ii. The Permittee shall be deemed to be in noncompliance with 15A NCAC 02D .0521 if:

(A) the source is not immediately shut down and repaired per c.i.(A) above;

(B) the demonstration in c.i.(B) above cannot be made;

(C) the monthly observations are not conducted per c.i above; or

(D) "normal" is not established for per c.i above.

Recordkeeping [15A NCAC 02Q .0508(f)] d. The results of the monitoring shall be maintained in a logbook (written or electronic format) on-site and

made available to an authorized representative upon request. The logbook shall record the following:

i. the date and time of each recorded action;

11. the results of each observation and/or test noting those sources with emissions that were observed to be in noncompliance along with any corrective actions taken to reduce visible emissions; and

111. the results of any corrective actions performed.

The Permittee shall be deemed in noncompliance with 15A NCAC 02D .0521 if these records are not maintained.

Reporting f15A NCAC 02Q .0508(±)] e. The Permittee shall submit a summary report of the monitoring and record.keeping in Paragraphs c. and d.

above postmarked on or before January 30 of each calendar year for the preceding six-month period between July and December and July 30 of each calendar year for the preceding six-month period between January and June. All instances of deviations from the requirements of this permit must be clearly identified.

Page 50: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennii No. 01001 T56 Page 43

K. wastewater treatment facility lime storage silo (ID No. ES-WWTF Silo) with associated bin vent filter (ID No. CD-WWTF-Silo-BF)

The following table provides a summary of limits and standards for the emission source( s) described abo¥ e: Regulated

Limits/Standards Applicable Regulation Pollutant

particulate matter ambient air quality standards 15ANCAC 02D .0510

visible emissions 20 percent opacity ( except during startups, shutdowns, 15ANCAC 02D .0521 and malfunctions) when averaged over a six-minute period except that six-minute periods averaging not more than 87 percent opacity may occur not more than once in any hour nor more than four times in any 24-hour period

toxic air See Section 2.2.A.l.b 15ANCAC 02D .1100 pollutants State-only requirement

1. 15A NCAC 02D .0510: PARTICULATES FROM SAND, GRAVEL, OR CRUSHED STONE OPERATIONS

a. The Pennittee shall not cause, allow, or permit any material to be produced, handled, transported or stockpiled without taking measures to reduce to a minimum any particulate matter from becoming airborne to prevent exceeding the ambient air quality standards beyond the property line for particulate matter, both PMlO and total suspended particulates.

b. Fugitive non-process dust emissions shall be controlled by 15A NCAC 02D .0540.

c. The Petmittee shall control emissions from conveyors, screens, and transfer points, such that the applicable opacity standards in Section 2.1.K.2.a below are not exceeded.

Testing [15A NCAC 02D .2601] d. If emissions testing is required, the testing shall be performed in accordance with General Condition JJ. If

the results of this test are above the limits given in Section 2.1.K.2 below, the Permittee shall be deemed in noncompliance with 15ANCAC 02D .0510.

Monitoring [15ANCAC 02Q .0508(f)] e. Particulate matter emissions from this source (ID No. ES-WWTF Silo) shall be controlled by the associated

bin vent filter (ID No. CD-WW1F-Silo-BF). To ensure compliance, the Permittee shall perform inspections and maintenance as recommended by the manufacturer. In addition to the manufacturer's inspection and maintenance recommendations, or if there are no manufacturer's inspection and maintenance recommendations, as a minimum, the inspection and maintenance requirement shall include the following: i. A monthly visual inspection of the system ductwork and material collection unit for leaks; and ii. An annual (for each 12-month period following the initial inspection) internal inspection of the bin vent

filter's structural integrity. The Pennittee shall be deemed in noncompliance with 15A NCAC 02D .0510 if the ductwork and bin vent filter are not inspected and maintained.

Recordkeeping [15A NCAC 02Q .0508(t)] f. The results of inspection and maintenance in Section 2.1.K.1.e above shall be maintained in a logbook (written

or electronic format) on-site and made available to an authorized representative upon request. The logbook shall record the following:

Page 51: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 01001 T56 Page 44

1. The date and time of each recorded action; ii. The results of each inspection; m. The results of any maintenance performed on the bin vent filter; and iv. Any variance from manufacturer's recommendations, if any, and corrections made. The Pennittee shall be deemed in noncompliance with 15A NCAC 02D .0510 if these records are not maintained.

Reporting [15A NCAC 02Q .0508(f)] g. The Pennittee shall submit a summary report of the monitoring and recordkeeping activities by January 30 of

each calendar year for the preceding six-month period between July and December and July 30 of each calendar year for the preceding six-month period between January and June. All instances of deviations from the requirements of this permit must be clearly identified.

2. 15A NCAC 02D .0521: CONTROL OF VISIBLE EMlSSIONS

a. Visible emissions from this source shall not be more than 20 percent opacity ( except during startups, shutdowns, and malfunctions) when averaged over a six-minute period. However, six-minute averaging periods may exceed 20 percent not more than once in any hour and not more than four times in any 24-hour period. In no event shall the six-minute average exceed 87 percent opacity.

Testing (15A NCAC 02D .2601] b. If emissions testing is required, the testing shall be performed in accordance with 15A NCAC 02D .2601

and General Condition JJ. If the results of this test are above the limits given in Section 2. l .K.2.a, the Permittee shall be deemed in noncompliance with 15A NCAC 02D .0521.

Monitoring [15A NCAC 02Q .0508(f)] c. To assure compliance, once a month the Permittee shall observe the emission points of this source (ID No.

ES-WWTF Silo) for any visible emissions above normal. The Permittee shall establish "nonnal" for the source in the first 30 days following start-up of the sources. If visible emissions from this source are observed to be above normal, the Permittee shall either: (a) immediately shutdown the source and repair the malfunction, (b) be deemed to be in noncompliance with 15A NCAC 02D .0521 or (c) demonstrate that the percent opacity from the emission points of the emission sources in accordance with 15A NCAC 02D .2601 for 30 minutes is below the limit given in Section 2.1.K.2.a above. If the demonstration in ( c) above cannot be made, the Permittee shall be deemed to be in noncompliance with ISA NCAC 02D .0521.

Recordkeeping [15A NCAC 02Q .0508(f)] d. The results of the monitoring shall be maintained in a logbook (written or electronic format) on-site and

made available to an authorized representative upon request. The logbook shall record the following: i. the date and time of each recorded action; 11. the results of each observation and/or test noting those sources with emissions that were observed to be

in noncompliance along with any corrective actions taken to reduce visible emissions; and 111. the results of any corrective actions performed. The Permittee shall be deemed in noncompliance with 15A NCAC 02D .0521 if these records are not

maintained.

Reporting [15A NCAC 02Q .0508(f)] e. The Permittee shall submit a summary report of the observations postmarked on or before January 30 of

each calendar year for the preceding six-month period between July and December and July 30 of each calendar year for the preceding six-month period between January and June. All instances of deviations from the requirements of this permit must be clearly identified.

Page 52: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Page 45

2.2- Multiple Emission Sources

A. Facility Wide Toxics Demonstration

h £ 11 T e o owmg table prov1 es a summary o 'd 1ts an stan s or t e ennssion source s escn a o flim' d dard fi h ( ) d 'bed b ve:

Regulated Limits/Standards Applicable Regulation Pollutant

toxic air pollutants Emissions rates modeled to demonstrate 15ANCAC 02D .1100 compliance with acceptable ambient levels. State-enforceable Only

See Section 2.2 A.1.a

State-enforceable Only 1. 15A NCAC 02D .1100: CONTROL OF TOXIC AIR POLLUTANTS

a. Pursuant to 15A NCAC 02D .1100 and in accordance with the approved application for an air toxic compliance demonstration, the following permit limits shall not be exceeded:

Emission Source Toxic Air Pollutant Emission Limit

(lb/yr) (lb/day) (lb/hr)

wastewater treatment facility (bio-reactor) hydrogen sulfide 5.41 E+Ol ES-WWTFBR

wastewater treatment facility Arsenic and inorganic arsenic l.93E-03 compounds lime storage silo

Beryllium 2.77E-03 ES-WWTF Silo Cadmium l.52E-02

Manganese and compounds 2.00E-02

Mercury Vapor 2.66E-06

Nickel Metal l.20E-03 Unit I dry flyash pneumatic Arsenic and inorganic arsenic

7.95E-01 transfer system compounds ES-FA Handling 1 Beryllium 1.64E+00

Cadmium l.47E+O0

Manganese and compounds 1.06E+-O0 Mercury Vapor 3.27E-03

Nickel Metal 4.36E-01 Soluble Chromate Compounds

4.51E-02 as Chromium Vl Equivalent Unit 3 dry flyash pneumatic Arsenic and inorganic arsenic

3.0lE-01 transfer systems compounds ES-FA Handling 3A Beryllium 3.72E+00 ES-FA Handling 3B Cadmium 3.33E+00 ES-Surge Bin 3

Manganese and compounds 4.0lE-01

Page 53: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pem1it No. OJ 001 T56 Page 46

Unit 4 dry flyash pneumatic transfer systems ES-FA Handling 4A ES-FA Handling 4B ES-FA Handling 4C

flyash conveying system storage and handling silos ES-FA Silo 1 ES-FA Silo 2 ES-FA Silo 4

flyash conveying system storage and handling silo ES-FA Silo 5

No. 1 flyash conveying system storage and handling silo and load-out stations ES-S•l

No. 4 flyash conveying system storage and handling silo and load-out stations ES-S·4

Mercury Vapor

Nickel Metal

Soluble Chromate Compounds as Chromium VI Equivalent Arsenic and inorganic arsenic compounds

Beryllium

Cadmium

Manganese and compounds

Mercury Vapor

Nickel Metal

Soluble Chromate Compounds as Chromium VI Equivalent Arsenic and inorganic arsenic compounds

Beryllium

Cadmium

Manganese and compounds

Mercury Vapor

Nickel Metal

Soluble Chromate Compounds as Chromium VI Equivalent Arsenic and inorganic arsenic compounds

Beryllium

Cadmium

Manganese and compounds

Mercury Vapor

Nickel Metal

Soluble Chromate Compounds as Chromium VI Eouivalent Arsenic and inorganic arsenic compounds

Beryllium

Cadmium

Manganese and compounds

Mercury Vapor

Nickel Metal

Soluble Chromate Compounds as Chromium VI Eouivalent Arsenic and inorganic arsenic comoounds Beryllium

Cadmium

Manganese and compounds

Mercury Vapor

l.24E-03

l .65E-01

l .70E-02

3.0lE-01

3.72E+OO

3.33E+OO

4.0lE-01

l.24E-03

l.65E-01

l.70E-02

4.48E+Ol

9.23E+Ol

8.27E+Ol

5.96E+Ol

l.84E-01

2.45E+Ol

2.54E+o0

l.49E+Ol

3.0SE+Ol

2.76E+Ol

1.99E+Ol

6.13E--02

8.17E+OO

8.46E-Ol

5.03E-02

1.04E-01

9.30E-02

6.70£.02

2.07E-04

2.76E--02

2.85E-03

5.03E-02

l .04E·Ol

9.30E•02

6.70E-02

2.07E-04

Page 54: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pcnnit No. 0100 l T56 Page 47

No. 5 flyash conveying system storage and handling silo and load-out stations ES-S-5

electrostatic flyash separation system and mineral-rich product load-out silo ES-S-3L

two electrostatic flyash separation systems and associated conveying systems ES-EFSSl ES-EFSS2

six coal storage silos ES-Coal Silos 1-6

four coal conveyors ES•37 A. ES-37B, ES-39A, ES-39B

stationary vacuum system for housekeeping ES-SVSI

Nickel Metal

Soluble Chromate Compounds as Chromium VI Equivalent Arsenic and inorganic arsenic compounds

Beryllium

Cadmium

Manganese and compounds

Mercury Vapor

Nickel Metal

Soluble Chromate Compounds as Chromium VI Equivalent Arsenic and inorganic arsenic compounds

Beryllium

Cadmium

Manganese and compounds

Mercury Vapor

Nickel Metal

Soluble Chromate Compounds as Chromium VI Equivalent Arsenic and inorganic arsenic compounds Beryllium

Cadmium

Manganese and compounds

Mercury Vapor

Nickel Metal

Soluble Chromate Compounds as Chromium VT Equivalent Arsenic and inorganic arsenic compounds

Beryllium

Cadmium

Manganese and compounds

Mercury Vapor

Nickel Metal

Arsenic and inorganic arsenic compounds

Beryllium

Cadmium

Manganese and compounds

Mercury Vapor

Nickel Metal

Soluble Chromate Compounds as Chromium VI Equivalent

2.76E-02

2.85E-03

5.03E-02

l.04E-01

9.30E-02

6.70E-02

2.07E-04

2.76E-02

2.85E-03

l.OlE+OO

2.08E+OO

1.87E+OO

l.35E+OO

4.lSE-03

5.53E-01

5.73E-02

l.OlE+oO

2.08E+OO

1.87E+OO

l.35E+OO

4.lSE-03

5.53E-Ol

5.73E-02

4.20

6.51

5.83

4.20

0.01

1.73

4.92E-02

1.0lE-01

9.09E-02

2.39E+01

7.38E-02

9.84E+OO

l.02E+OO

Page 55: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pem1it No. 01001 T56 Page 48

flyash conveying system storage and handling silo ES-FA Silo 3

mineral-rich flyash loadout system ES-S-3L2

coal unloading hopper

ES-Coal Hopper

coal conveyor ES-Coal Conv 1

coal conveyor ES-Coal Conv 2

limestone rail unloading station ES-LS Rail

two limestone unloading hoppers ES-LS Unload A ES-LS Unload B

belt feeder ES-LS Feeder 1

limestone conveyor ES-LS Convey 2 ES-LS Convey 4A ES-LS Convey 4B ES-LS Convey 5

Arsenic and inorganic arsenic l.49E+Ol

compounds

Beryllium 3.08E+Ol

Cadmium 2.76E+01

Manganese and compounds 1.99E+Ol

Mercury Vapor 6.13E-02

Nickel Metal 8.l 7E+OO Soluble Chromate Compounds

8.46E-01 as Chromium VI Eauivalent Arsenic and inorganic arsenic

l.93E+OO compounds

Beryllium 2.99E+OO

Cadmium 2.68E+OO

Manganese and compounds l.93E+OO

Mercury Vapor 5.96E-03

Nickel Metal 7.94E-Ol Arsenic and inorganic arsenic

l.69E-01 compounds

Beryllium 2.62E-01

Cadmium 2.35E-Ol

Manganese and compounds l.69E-OI

Mercury Vapor 5.22E-04

Nickel Metal 6.96E-02 Arsenic and inorganic arsenic

l.69E-Ol compounds

Beryllium 2.62E-Ol

Cadmium 2.35E-01

Manganese and compounds 1 .69E-01 Mercury Vapor 5.22E-04

Nickel Metal 6.96E-02

Arsenic and inorganic arsenic 2.66E-02

compounds

Beryllium 5.ZOE-02

Cachnium l.40E-01

Manganese and compounds 3.86E-Ol

Mercury Vapor 9.37E-05

Nickel Metal l.38E-02

Arsenic and inorganic arsenic compounds l.33E-01

Beryllium 2.60E-Ol

Cadmium 7.02B-Ol

Manganese and compounds l.93E+OO

Mercury Vapor 4.69E-04 Nickel Metal 6.88E-02

Page 56: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Penni! No. 01001 T56 Page 49

ES-LS Convey 6 ES-LS Convey 7

two limestone reclaim hoppers ES-LS Reclaim A ES-LS Reclaim B

two belt feeders ES-LS Feeder 3A ES-LS Feeder 3B

three limestone silos ES-LS Silo A ES-LS SiloB ES-LS Silo C

limestone silo storing material for Mayo plant ES-LS Mayo Silo

truck loading spout from Mayo limestone silo ES-Truck Spout

three wet limestone grinders ES-LS Grinder 1 ES-LS Grinder 2 ES-LS Grinder 3

Fugitive emissions from coal pile including ash landfill and (ID No. IS-36)

-

1;

Arsenic and inorganic arsenic 1.43E-01 compounds

Beryllium 2.S0E-01 Cadmium 7.57E-01

Manganese and compounds 2.08E+0O Mercury Vapor 5.05E-04

Nickel Metal 7.42E-02 Arsenic and inorganic arsenic

12.95 compounds Beryllium 25.93 Cadmium 23.22

Manganese and compounds 16.74

Mercury Vapor 0.05

Nickel Metal 6.88 Soluble Chromate Compounds

0.65 as Chromium VI Equivalent

Page 57: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air QualityPcnnil No. 01001 T56 .Page 50

Gypsum emergency conveyor (ID No. IS-38)

Emergency gypsum pile (ID No. IS-40)

Mayo gypsum rotary feeder (ID No. IS-41)

Gypsum conveyor 3 (includes 3a and 3b) (ID No. IS-44)

Landfill gypsum loading hopper (ID No. IS-48)

Landfill gypsum reclaim belt feeder (ID No. IS-49)

Off-specification gypsum pile (ID No. IS-45)

On-specification gypsum pile (ID No. IS-46)

Arsenic and inorganic arsenic compounds

Cadmium

Manganese and compounds

Mercury Vapor

Nickel Metal

Arsenic and inorganic arsenic compounds

Cadmium

Manganese and compounds

Mercury Vapor

Nickel Metal

Monitoring/Recordkeeping/Reporting

,,~ ·-

6.80E-02

6.21E-01

2.54E+00

l,49E-03

2.79E-02

6.18E-02

5.64E-01

2.30E+00

l.35E-03

2.53E-02

b. No monitoring, recordkeeping, or reporting shall apply to any emission sources included in Section 2.2 A.I.a above.

-

Page 58: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001T56 .Page 51

B. Electric generating units:

• ES-Unit 1, • ES-Unit 2, • ES-Unit 3A, • ES-Unit 3B, • ES-Unit 4A, and • ES-Unit 4B

Federal-Enforceable Onlv 1. Cross State Air Pollution Ruic (CSAPR) Requirements

a. For the electric utility boilers (ID Nos. ES-Unit 1, ES-Unit 2, ES-Unit 3A, ES-Unit 3B, ES-Unit 4A, and ES-Unit 4B), the Pennittee shall comply with all applicable requirements of 40 CFR Part 97, Subpart AAAAA "TR NOx Annual Trading Program", Subpart BBBBB "TR NOx. Ozone Season Trading Program", and Subpart CCCCC "TR S02 Group 1 Trading Program".

2. 15A NCAC 02D .1111: MAXIMUM ACHIEVABLE CONTROL TECHNOLOGY (40 CFRPART 63 SUBPART UUUUU)

a. The Permittee shall comply with all applicable provisions, including the requirements for emission limitations, work practice standards, operating limits, testing and initial compliance, continuous compliance, monitoring, record.keeping, notification, and reporting, contained in Environmental Management Commission Standard 15A NCAC 02D .1111 Maximum Achievable Control Technology (MACT) as promulgated in the most current version of 40 CFR Part 63 Subpart UUUUU, "National Emission Standards for Hazardous Air Pollutants: Coal- and Oil-Fired Electric Utility Steam Generating Units" and Subpart A General Provisions.

Emission Limitations and Work Practice Standards [15A NCAC 02Q .0508(b)J b. The Pennittee shall:

i. limit the emissions of filterable particulate matter (PM) to 3.0E-2 pounds per million Btu (lb/MMBtu);

11. limit the emissions of hydrogen chloride (HCI) to 2.0E-3 lb/MMBtu; and

m. limit the emissions of mercury (Hg) to 1.3E-02 pounds per gigawatt-hour (lb/GWh).

[40 CFR 63.999l(a)(l) and Table 2 to Subpart UUUUU]

c. 1. As an alternative to meeting the requirements of §63.9991(a)(1) for filterable PM, SO2, HF, HCl, non­Hg HAP metals, or Hg on an EGU-specific basis as described in paragraph a above, the Pennittee may choose to demonstrate compliance by using emissions averaging as described in §63.l 0009(a)(2) among existing EGUs in the same subcategory. If this option is selected for mercury, the Permittee shall limit the concentration of mercury to 1.0 lbtrBtu or l .lE-2 lb/GWh. [§63.999l(a)(l), §63.10009 and §63 .10022]

11. As an alternative to the emission limit in Sections 2.2 B.2.b.i through iii., the Pennittee may comply with the relevant emission limits in paragraphs (A) through (C) below provided that the Permittee complies with the requirements of Section 2 .1 A.11.c.iii:

(A) As an alternative to the emission limit in Section 2.2 B.2.b.i, the Permittee may:

Page 59: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 01001 T56 Page 52

(I) limit the emissions of filterable particulate matter (PM) to 3.0E 1 pounds per megawatt-hour (lb/MWh); or

(II) limit the emissions of total non-Hg HAP metals to 5.0E-5 lb/MMBtu; or

(III) limit the emissions of total non-Hg HAP metals to 5.0E-1 lb/GWh; or

(IV) limit the emissions of individual HAP metals to the amounts listed in Table 2 to 40 CFR Part 63, Subpart UUUUU.

(B) As an alternative to the emission limit in Section 2.2 B.2.b.ii., the Pennittee may:

(I) limit the emissions of HCl to 2.0E-2 lb/MWh; or

(II) limit the emissions of sulfur dioxide (S02) to 2.0E-1 lb/MMBtu; or

(Ill) limit the emissions of SO2 to I .SEO lb/MWh.

(C) As an alternative to the emission limit in Section 2.2 B.2.b.iii., the Permittee may limit the emissions of mercury to 1.2 pounds per trillion Btu (lbfTBtu).

[§63.9991(a)(l) and Table 2 to Subpart UUUUU]

iii. The Permittee may demonstrate compliance with the emission limits in Section 2.2 B.2.c.ii., provided that:

(A) The Permittee shall submit a request that identifies for each EGU or EGU emissions averaging group involved in the proposed switch both the cwrent and proposed emission limit;

(B) The above request arrives to the Administrator at least 30 calendar days prior to the date that the switch is proposed to occur;

(C) The request demonstrates through performance stack test results completed within 30 days prior to the submission, compliance for each EGU or EGU emissions averaging group with both the mass per heat input and mass per gross output limits;

(D) The Permittee revises and submits all other applicable plans, e.g., monitoring and emissions averaging, with the request; and

(E) The Permittee maintains records of all information regarding the choice of emission limits.

[§63.10030(e)(7)(iii)]

d. During periods of startup of an EG U:

i. The Pennittee has chosen to comply using the following work practice standards, by choosing to comply using paragraph (l) of the definition of"startup" in §63.10042, defined as follows.

Startup means either the first-ever firing of fael in a boiler for the purpose of producing electricity, or the firing of feel in a boiler after a shutdown event for any purpose. Startup ends when any of the steam from the boiler is used to generate electricity for sale over the grid or/or any other purpose (including on site use). Any fraction ~fan hour in which startup occurs constitutes a fall hour of startup.

Page 60: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Page 53

The Permittee shall operate all continuous monitoring systems (CMS) during startup, except during periods of bypass of the main stack as provided in §63. lO0lO(a)( 4). For startup of a unit, clean fuels must be used as defined in §63.10042 for ignition. Once the unit converts to firing coal, the Permittee shall engage all of the applicable control technologies except the SCR. The Permittee shall start the SCR system appropriately to comply with relevant standards applicable during nonnal operation. The Permittee shall comply with all applicable emissions limits at all times except for periods that meet the applicable definitions of startup and shutdown in Subpart UUUUU. The Pennittee shall keep records during startup periods.

ii. If the Permittee chooses to use just one set of sorbent traps to demonstrate compliance with the applicable Hg emission limit, the Permittee shall comply with the limit at all times; otherwise, the Permittee shall comply with the applicable emission limit at all times except for startup and shutdown periods.

m. The Permittee shall collect monitoring data during startup periods, as specified in §63.10020(a) and ( e). The Perm:ittee shall keep records during startup periods, as provided in §§63.10032 and 63.10021(h). The Pennittee shall provide reports concerning activities and startup periods, as specified in §63.1001 l(g) and §63.10021 (h) and (i). All periods of bypass of the main stack shall be reported as deviations as provided in §63.10010(a)(4)(ii).

(§63.999l(a)(l) and Table 3 to Subpart UUUUU]

e. During periods of shutdown of an EGU:

Shutdown means the period in which cessation of operation of an EGU is initiated for any purpose. Shutdown begins when the EGU no longer generates electricity or makes useful thermal energy (such as heat or steam) for industrial, commercial, heating, or cooling purposes or when no coal, liquid oil, syngas, or solid oil-derivedfael is beingfired in the EGU, whichever is earlier. Shutdown ends when the EGU no longer generates electricity or makes usefal thennal energy (such as steam or heat) for industrial, commercial, heating, or cooling purposes, and no fuel is being fired in the EG U Any fraction of an hour in which shutdown occurs constitutes a full hour of shutdown.

1. The Pennittee shall operate all CMS during shutdown, except during periods of bypass of the main stack as provided in §63.10010( a)( 4 ). The Permittee shall also collect appropriate data, and shall calculate the pollutant emission rate for each hour of shutdown for those pollutants for which a CMS is used. While firing coal during shutdown, the Permittee shall vent emissions to the main stack(s) and operate all applicable control devices and continue to operate those control devices after the cessation of coal being fed into the EGU and for as long as possible thereafter considering operational and safety concerns as provided for bypass of the main stack in §63.10010(a)(4). In any case, the pennittee shall operate the controls when necessary to comply with other standards made applicable to the EGU by a permit limit or a rule other than Subpart UUUUU and that require operation of the control devices. All periods of bypass of the main stack shall be reported as deviations as provided in §63.10010(a)(4)(ii).

n. If, in addition to the fuel used prior to initiation of shutdown, another fuel must be used to support the shutdown process, that additional fuel shall be one or a combination of the clean fuels defined in §63.10042 and shall be used to the maximum extent possible taking into account considerations such as not compromising boiler or control device integrity.

m. The Permittee shall comply with all applicable emission limits at all times except during startup periods and shutdown periods at which time the Permittee shall meet the work practice standards. The Pennittee shall collect monitoring data during shutdown periods, as specified in §63.10020(a). The

Page 61: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Page 54

Pennittee shall keep records during shutdown periods, as provided in §§63.I0032 and 63.1002l(h). The Pennittee shall provide reports concerning activities and shutdown periods, as specified in §§63.1001 l(g), 63.10021(i), and 63.10031.

[§63.9991(a)(1 ), §63.10042, and Table 3 to Subpart UUUUUJ

General Compliance Requirements [ISA NCAC 02Q .0508(f)] f. The Pennittee shall comply with the General Provisions as applicable pursuant to Table 9 to Subpart

UUUUU. [40 CFR 63.10040]

g. The Pennittee shall be in compliance with the emission limits and operating limits in Subpart UUUUU. These limits shall apply at all times except during periods of startup and shutdown; however, for coal-fired EGU s, the Permittee shall be required to meet the work practice requirements in Table 3 to Subpart UUUUU during periods of startup or shutdown. [§63.l OOOO(a)]

h. At all times, the Pennittee shall operate and maintain any affected source, including associated air pollution control equipment and monitoring equipment, in a manner consistent with safety and good air pollution control practices for minimizing emissions. Detennination of whether such operation and maintenance procedures are being used will be based on information available to the EPA Administrator which may include, but is not limited to, monitoring results, review of operation and maintenance procedures, review of operation and maintenance records, and inspection of the source. [§63.lOOOO(b)J

i. For coal-fired units, initial performance testing is required for all pollutants for the affected EGUs to demonstrate compliance with the applicable emission limits. [§63.IOOOO(c)(l)]

J. The Permittee shall demonstrate compliance with the filterable particulate matter (PM) emission limit through an foitial performance test and shall monitor continuous performance through use of a PM continuous emissions monitoring system (PM CEMS). [§63.lOOOO(c)(l)(iv)]

k. The Permittee shall demonstrate initial and continuous compliance by conducting an initial and periodic quarterly performance stack test for HCJ. [§63.IOOOO(c)(l)(v)]

I. The Pennittee shall demonstrate initial and continuous compliance through use of a Hg CEMS or a sorbent trap monitoring system in accordance with Appendix A to the Subpart. [ §63 .10000( c )(1 )(vi)]

m. As part of demonstration of continuous compliance, the Permittee shall perform periodic tune-ups of the affected EGUs, according to §63.10021(e). [§63.lOOOO(e)]

n. On or before the date an EGU is subject to Subpart UUUUU, the Pennittee shall install, certify, operate, maintain, and quality-assure each monitoring system necessary for demonstrating compliance with the work practice standards for PM during startup periods and shutdown periods. The Permittee shall collect, record, report, and maintain data obtained from these monitoring systems during startup periods and shutdown periods. [§63.10000(1)]

The Permittee shall be deemed in noncompliance with 15A NCAC 02D .1111 if the general compliance requirements in Sections 2.2 B .2.f through n above are not met.

Continuous Compliance Requirements [15ANCAC 02Q .0508(f)] o. The Pennittee shall monitor and collect data according to §63.10020. [§63.10020(a)]

p. The Pennittee shall operate the monitoring system and collect data at all required intervals at all times that the affected EGU is operating, except for periods of monitoring system malfunctions or outRof-control periods (see §63.8(c)(7)), and required monitoring system quality assurance or quality control activities,

Page 62: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pe11nit No. 01001 T56 Page 55

including, as applicable, calibration checks and required zero and span adjustments. The Pennittee is required to affect monitoring system repairs in response to monitoring system malfunctions and to return the monitoring system to operation as expeditiously as practicable. [§63.10020(b)]

q. Except for periods of monitoring system malfunctions or monitoring system out-of-<:ontrol periods, repairs associated with monitoring system malfunctions or monitoring system out-of-control periods, and required monitoring system quality assurance or quality control activities including, as applicable, calibration checks and required zero and span adjustments, failure to collect required data is a deviation from the monitoring requirements. [ § 63.10020( d)]

r The Pennittee shall demonstrate continuous compliance with each emissions limit, operating limit, and work practice standard in Tables 2 and 3 to Subpart UUUUU that applies to the affected EGU, according to the monitoring specified in Table 7 to Subpart UUUUU and paragraphs (b) through (g) of §63.l0021(a). [§63.10021 (a)]

s. Except as otherwise provided in §63.10020(c), if the Permittee uses a CEMS to measure S02, PM, HCl, HF, or Hg emissions, or uses a sorbent trap monitoring system to measure Hg emissions, the Pennittee shall demonstrate continuous compliance by using all quality-assured hourly data recorded by the CEMS (or sorbent trap monitoring system) and the other required monitoring systems ( e.g., flow rate, CO2, 02, or moisture systems) to calculate the arithmetic average emissions rate in units of the standard on a continuous 30-boiler operating day ( or, if alternate emissions averaging is used for Hg, 90-boiler operating day) rolling average basis, updated at the end of each new boiler operating day. The Permittee shall use Equation 8 to Subpart UUUUU to determine the 30- ( or, if applicable, 90-) boiler operating day rolling average.

L~1 Her1 Boiler operating day average = - (Eq. 8) n

Where:

Her; is the hourly emissions rate for houri and n is the number of hourly emissions rate values collected over 30- ( or, if applicable, 90-) boiler operating days.

[§63.10021 (b )]

t. The Permittee shall conduct periodic performance tune-ups of the EGUs, as specified in paragraphs (e)(l) through (9) of §63.10021. The Permittee shall perform an inspection of the burner at least once every 36 calendar months unless the EGU employs neural network combustion optimization during normal operations in which case an inspection of the burner and combustion controls shall be performed at least once every 48 calendar months. If the EGU is offiine when a deadline to perform the tune-up passes, the tune-up work practice requirements shall be performed within 30 days after the re-start of the affected unit. [§63.1002l{e)]

u. The Pennittee shall follow the startup or shutdown requirements as given in Table 3 to the Subpart for each coal-firedEGU and comply with all applicable requirements in §63.1001 l(g). [§§63.100050), 63.1001 l(g) and §63.1002l(h)]

v. The Pennittee shall determine the fuel whose combustion produces the least uncontrolled emissions, taking safety considerations into account, i.e., the cleanest fuel, either natural gas or distillate oil, that is available on site or accessible nearby for use during periods of startup or shutdown. The cleanest fuel, either natural gas or distillate oil, for use during periods of startup or shutdown determination may take safety considerations into account. [§§63.1001 l(t)(l) and (2)]

The Permittee shall be deemed in noncompliance with 15ANCAC 02D .1111 if the continuous compliance

Page 63: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 01001 T56 Page 56

requirements in Sections 2.2 B.2.o through v above are not met.

Monitoring [15A NCAC 02Q .0508(f)] w. For an affected unit that exhausts to the atmosphere through a single, dedicated stack, the Permittee shall

either install the required ·cEMS and sorbent trap monitoring systems in the stack or at a location in the ductwork downstream of all emissions control devices, where the pollutant and diluents concentrations are representative of the emissions that exit to the atmosphere. [§63.lOOlO(a)(l)]

x. If the Pennittee uses an oxygen (02) or carbon dioxide (CO2) CEMS to convert measured pollutant concentrations to the units of the applicable emissions limit, the 02 or CO2 concentrations shall be monitored at a location that represents emissions to the atmosphere, i.e., at the outlet of the EGU, downstream of all emission control devices. The Permittee shall install, certify, maintain, and operate the CEMS according to 40 CFR Part 75. Use only quality-assured 02 or CO2 data in the emissions calculations; do not use Part 75 substitute data values. [§63.lOOlO(b)]

y. If the Permittee is required to use a stack gas flow rate monitor, either for routine operation of a sorbent trap monitoring system or to convert pollutant concentrations to units of an electrical output-based emission standard in Table 2 to Subpart UUUUU, the Pennittee shall install, certify, operate, and maintain the monitoring system and conduct on-going quality-assurance testing of the system according to 40 CFR Part 75. The Permittee shall use only unadjusted, quality-assured flow rate data in the emissions calculations. The Permittee shall not apply bias adjustment factors to the flow rate data and do not use substitute flow rate data in the calculations. [§63.IOOIO(c)]

z. If the Permittee is required to make corrections for stack gas moisture content when converting pollutant concentrations to the units of an emission standard in Table 2 to Subpart UUUUU, the Permittee shall install, certify, operate, and maintain a moisture monitoring system in accordance with 40 CPR Part 75. Alternatively, for coal-fired units, the Pennittee may use appropriate fuel-specific default moisture values from §75.ll(b) to estimate the moisture content of the stack gas. If the Permittee installs and operates a moisture monitoring system, the Permittee shall not use substitute moisture data in the emissions calculations. [§63.lOOlO(d)]

aa. The Permittee shall conduct all applicable periodic HCl emissions tests according to Table 5 to Subpart UUUUU and §63.10007 at least quarterly, ~xcept as otherwise provided in §63.10021(d)(l). [§63.10006(d)]

bb. The Pennittee shall use a Hg CEMS or a sorbent trap monitoring system. The Pennittee shall install, certify, operate, maintain and quality-assure the data from the monitoring system in accordance with Appendix A to Subpart UUUUU and as specified in §63.lOOIO(g). [§63.lOOlO(g)]

cc. The Pennittee shall install, certify, operate, and maintain a PM CEMS and record the output of the PM CEMS as specified in paragraphs (i)(l) through (5) of §63.10010 (shown below). The compliance limit shall be expressed as a 30-boiler operating day rolling average of the applicable numerical emissions limit value in Table 2 to Subpart UUUUU.

i. Install and certify the PM CEMS according to the procedures and requirements in Performance Specification 11 -Specifications and Test Procedures for Particulate Matter Continuous Emission Monitoring Systems at Stationary Sources in Appendix B to 40 CFR Part 60, using Method 5 at Appendix A-3 to 40 CPR Part 60 and ensuring that the front half filter temperature shall be 160° ±14 °C (320° ±25 °F). The reportable measurement output from the PM CEMS must be expressed in units of the applicable emissions limit (e.g., lb/MMBtu, lb/MWh).

ii. Operate and maintain the PM CEMS according to the procedures and requirements in Procedure 2-Quality Assurance Requirements for Particulate Matter Continuous Emission Monitoring Systems at Stationary Sources in Appendix F to 40 CFR Part 60.

Page 64: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 01001 T56 Page 57

(A) Conduct the relative response audit (RRA) for the PM CEMS at least once annually (once per 12 month period).

(B) Conduct the relative correlation audit (RCA) for the PM CEMS at least once every 3 ( calendar) years.

iii. Collect PM CEMS hourly average output data for all boiler operating hours except as indicated in §63.lO0l0(i).

iv. Calculate the arithmetic 30-boiler operating day rolling average of all of the hourly average PM CEMS output data collected during all nonexempt boiler operating hours.

v. Collect data using the PM CEMS at all times the process unit is operating and at the intervals specified in §63.l00l0(a), except for periods of monitoring system malfunctions, repairs associated with monitoring system malfunctions, and required monitoring system quality assurance or quality control activities.

(A) Use all the data collected during all boiler operating hours in assessing the compliance with the operating limit except:

(I) Any data collected during periods of monitoring system malfunctions, repairs associated with monitoring system malfunctions, or required monitoring system quality assurance or quality control activities that temporarily interrupt the measurement of emissions (e.g., calibrations, certain audits). Report any monitoring system malfunctions or out of control periods in the annual deviation reports. Report any monitoring system quality assurance or quality control activities per the requirements of §63.10031(b);

(IT) Any data collected during periods when the monitoring system is out of control as specified in the site-specific monitoring plan, repairs associated with periods when the monitoring system is out of control, or required monitoring system quality assurance or quality control activities conducted during out-of-control periods. Report any such periods in the annual deviation report;

(Ill) Any data recorded during periods of startup or shutdown.

(B) Record and make available upon request results of PM CEMS system performance audits, dates and duration of periods when the PM CEMS is out of control to completion of the corrective actions necessary to return the PM CEMS to operation consistent with the site-specific monitoring plan.

[§63.lO0lO(i)]

The Pennittee shall be deemed in noncompliance with 15A NCAC 02D .1111 if the monitoring requirements in Sections 2.2.B.2. w through cc above are not met.

Recordkeeping [15A NCAC 02Q .0508(t)] dd. The Permittee shall keep records of the following:

i. Records required under appendix A and/or appendix B to Subpart UUUUU for continuous monitoring of Hg emissions.

ii. Each notification and report that is submitted to comply with Subpart UUUUU, including all documentation supporting any Initial Notification or Notification of Compliance Status or semiannual compliance report that was submitted, according to the requirements in §63.10(b)(2)(xiv).

Page 65: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Penni! No. 01 001 T56 Page 58

iii. Records of performance stack tests, fuel analyses, or other compliance demonstrations and performance evaluations, as required in §63.10(b)(2)(viii). [§63.10032(a)J

ee. For each CEMS, the Permittee shall keep records as follows:

i. Records described in §63.10(b)(2)(vi) through (xi).

ii. Previous (i.e., superseded) versions of the performance evaluation plan as required in §63 .8( d)(3).

iii. Request for alternatives to relative accuracy test for CEMS as required in §63.8(f)(6)(i).

tv. Records of the date and time that each deviation started and stopped, and whether the deviation occurred during a period of startup, shutdown, or malfunction or during another period. [§63.10032(b)]

ff. For each EGU subject to an emission limit, the Permittee shall keep records of monthly fuel use by each EGU, including the type(s) of fuel and amount(s) used. [§63.10032(d)(l)]

gg. If the Permittee elects to average emissions consistent with §63 .10009 for any constituent, the Permittee must additionally keep a copy of the emissions averaging implementation plan required in §63.10009(f) andG), all calculations required under §63 .10009, including daily records of heat input or steam generation, as applicable, and monitoring records consistent with §63.10022. [§63.10032(e)]

hh. If the Permittee chooses to rely on paragraph (1) of the definition of "startup" in §63.10042 for any EGU, records must be kept of the occurrence and duration of each startup or shutdown. [§63.10032(f)(l)]

ii. The Permittee shall keep records of the occurrence and duration of each malfunction of an operation (i.e., process equipment) or the air pollution control and monitoring equipment. [ §63.10032(g)]

JJ. The Permittee shall keep records of actions taken during periods of malfunction to minimize emissions in accordance with §63 .I OOOO(b ), including corrective actions to restore malfunctioning process and air pollution control and monitoring equipment to its nonnal or usual manner of operation. [ §63 .1003 2(h)]

kk. The Permittee shall keep records of the type(s) and amount(s) of fuel used during each startup or shutdown. [§63.10032(i)]

11. The Permittee shall keep records in a form suitable and readily available for expeditious review, according to §63 .1 O(b )( 1 ). The Permittee shall keep each record for 5 years following the date of each occurrence, measurement, maintenance, corrective action, report, or record. The Permittee shall keep each record on site for at least 2 years after the date of each occurrence, measurement, maintenance, corrective action, report, or record. The Permittee can keep the records off site for the remaining 3 years. [§63.10033(a) through (c)]

The Permittee shall be deemed in noncompliance with 15A NCAC 02D .1111 if the record.keeping requirements in Sections 2.2 B.2.dd through ll above are not met.

Reporting [15A NCAC 02Q .0508(f)] mm. The Permittee shall submit the reports required under §63.10031 and, if applicable, the reports required

under appendices A and B to the Subpart. The electronic reports required by appendices A and B to the Subpart shall be sent to the Administrator electronically in a format prescribed by the Administrator, as provided in §63.10031. CEMS data (except for PM CEMS and any approved alternative monitoring using a HAP metals CEMS) shall be submitted using EPA's Emissions Collection and Monitoring Plan System (ECMPS) Client Tool. Other data, including PM CEMS data, HAP metals CEMS data, and CEMS performance test detail reports, shall be submitted in the file format generated through use of EP A's

Page 66: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit :Ko. 01001 T56 Page 59

Electronic Reporting Tool, the Compliance and Emissions Data Reporting Interface, or alternate electronic file format, all as provided for under §63 .10031. [§63.10021 (f)]

nn. The Permittee shall report each instance in which the Permittee did not meet an applicable emissions limit or operating limit in Tables 1 through 4 to 40 CFR 63 Subpart UUUUU or failed to conduct a required tune­up. These instances are deemed violations from the requirements of 40 CFR 63 Subpart UUUUU and shall be reported according to §63.10031. [§63.1002l(g)]

oo. The Permittee shall submit all of the notifications in §§63.7(b) and (c), 63.8 (e), (f)(4) and (6), and 63.9 (b) through (h), as applicable, by the dates specified, or according to an agreed upon schedule by NCDAQ [§63.9(i)(2)]. [§63.10030(a)J

pp. When the Permittee is required to conduct a performance test, the Permittee shall submit a Notification of Intent to conduct a perfonnance test at least 30 days before the performance test is scheduled to begin. [§63.10030(d)]

qq. The Pennittee shall submit each report in Table 8 to 40 CFR 63 Subpart UUUUU, as applicable. If the Permittee is required to ( or elect to) continuously monitor Hg and/or HCl and/or HF emissions, the Permittee shall also submit the electronic reports required under appendix A and/or appendix B to the Subpart, at the specified frequency. [§63.10031(a)]

rr. The Pennittee shall submit each report in Table 8 to 40 CFR 63 Subpart UUUUU, as applicable postmarked on or before January 30 of each calendar year for the preceding six-month period between July and December and July 30 of each calendar year for the preceding six-month period between January and June. All instances of deviations from the requirements of this permit must be clearly identified. [§63.1003l(b)]

ss. The compliance report shall contain the following:

1. The information required by the summary report located in 63 .10( e )(3 )(vi).

ii. The total fuel use by each affected source subject to an emission limit, for each calendar month within the semiannual reporting period, including, but not limited to, a description of the fuel, whether the fuel has received a non-waste determination by EPA or the basis for concluding that the fuel is not a waste, and the total fuel usage amount with units of measure.

111. Indicate whether the Permittee burned new types of fuel during the reporting period. If the Permittee did bum new types of fuel the Pennittee must include the date of the performance test where that fuel was in use.

1v. Include the date of the most recent tune-up for each EGU. The date of the tune-up is the date the tune­up provisions specified in §63.10021(e)(6) and (7) were completed.

v. A certification.

vi. If there is a deviation from any emission limit, work practice standard, or operating limit, the Permittee must also submit a brief description of the deviation, the duration of the deviation, emissions point identification, and the cause of the deviation.

vii. For each excess emissions occurring at an affected source where the Permittee is using a CMS to comply with that emission limit or operating limit, the Permittee shall include the information required in §63.10(e)(3)(v) in the compliance report specified in §63.10031(c). [§63.1003l(c) and §63.10031(d)J

Page 67: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pe11nit No. 01001 T56 Page 60

tt. Each affected source that has obtained a Title V operating permit pursuant to 40 CFR Part 70 or Part 71 shall report all deviations as defined in this subpart in the semiannual monitoring report required by 40 CFR 70.6(a)(3)(iii)(A) or 40 CFR 71.6(a)(3)(iii)(A). If an affected source submits a compliance report pursuant to Table 8 of Subpart UUUUU along with, or as part of, the semiannual monitoring report required by 40 CFR 70.6(a)(3)(iii)(A) or 40 CFR 71.6(a)(3)(iii)(A), and the compliance report includes all required information concerning deviations from any emission limit, operating limit, or work practice requirement in this subpart, submission of the compliance report satisfies any obligation to report the same deviations in the semiannual monitoring report. Submission of a compliance report does not otherwise affect any obligation the affected source may have to report deviations from permit requirements to the permit authority. [§63.10031(e)]

uu. On or after July 1, 2018, within 60 days after the date of completing each performance test, the Permittee shall submit the performance test reports required by the Subpart to EP A's WebFIRE database by using the Compliance and Emissions Data Reporting Interface (CEDRI) that is accessed through EPA's Central Data Exchange (CDX) (www.epa.gov/cdx). The Permittee shall comply with all applicable requirements in §63.1003l(fJ. [§63.10031(f)]

vv. If the Permittee had a malfunction during the reporting period, the compliance report must include the number, duration, and a brief description for each type of malfunction which occurred during the reporting period and which caused or may have caused any applicable emission limitation to be exceeded. [§63.10031(g)J

Page 68: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 01001 T56 Page 61

C. Sources covered under the Risk Management Plan

1. 15A NCAC 02D .2100: RISK MANAGEMENT PROGRAM

a. The Permittee is subject to Section l 12(r) of the Clean Air Act and shall comply with all applicable requirements in ISA NCAC 02D .2100 "Risk Management Program," as promulgated in 40 CFR Part 68.

Recordkceping/Reporting [15A NCAC 02Q .0508(f), (h)] b. The Pennittee submitted an update to the Risk Management Plan (RMP) to EPA pursuant to 40 CPR 68.150

on December 12, 2016.

c. The Permittee shall revise and update the RMP submitted under 40 CPR 68.150 no later than December 12, 2021, and at least every five years after that date or most recent update as required by 40 CFR 68. l 90(b )(2) through (b )(7), whichever is later.

d. When the Permittee submits the Annual Compliance Certification required by General Condition P, the Pennittee shall include a statement that the facility is in compliance with all requirements of 15A NCAC 02D .2100, including the registration and submission of the risk management plan.

Page 69: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 01001T56 Page 62

2.3- Permit Shield for Nonapplicable Requirements

This condition is to clarify that issuance of this permit provides no shield from the Act, or regulations promulgated thereunder, including state regulations, pertaining to requirements of the New Source Performance Standards or major or minor new source preconstruction review requirements. The permit may be subject to reopening to include a compliance plan and schedule addressing any past or ongoing noncompliance with those provisions for any affected emission units. [40 CFR 70.6(c)(3), 70.6(±) and 70.7(f)]

The Pennittee is shielded from the following nonapplicable requirements as of the date of issuance of this permit based on information furnished with all previous applications. This shield does not apply to future modifications or changes in the method of operation: [15A NCAC 02Q .0512(a)(l)(B)]

A. ISA NCAC 02D .0537 "Control of Mercury Emissions" is not applicable to the boilers because it does not apply to fuel combustion sources.

Page 70: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit ~o. 01001T56 Page 63

2.4- Phase II Acid Rain Permit Requirements

ORIS code: 2712 Effective: October 6, 2018 until September 30, 2023

A. Statement of Basis

Statutory and Regulatory Authorities: In accordance with the provisions of Article 21B of Chapter 143, General Statutes of North Carolina as amended and Titles IV and V of the Clean Air Act, the Division of Air Quality issues this permit pursuant to Title 15A North Carolina Administrative Codes, Subchapter 02Q .0400 and 02Q .0500, and other applicable Laws.

B, S02 Allowance Allocations and NOs Requirements for each affected unit

a. SO2 allowances:

S02 allowances (tons), per Tables 2, 3, or 4 of 40 CFR Part 73

Unit 2010 2011 2012 2013 2014 2015 and onwards

Boiler No.1 11,108* 11,108* 11,108* 11,108* 11,108* *

Boile1· No. 2 19,676* 19,676* 19,676* 19,676* 19,676* *

Boiler No. 3A 8,902* 8,902* 8,902* 8,902* 8,902* *

Boiler No. 3B 8,902* 8,902* 8,902* 8,902* 8,902* * Boiler No. 4A 10,425* 10,425* 10,425* 10,425* 10,425* *

Boiler No. 4B 10,425* 10,425* 10,425* 10,425* 10,425* *

* The number of allowances allocated to Phase II-affected units by U.S. EPA may change under 40 CPR Part 73. In addition, the number of allowances actually held by an affected source in a unit account may differ from the number allocated by U.S. EPA. Neither of the aforementioned conditions necessitates a revision to the unit SO2 allowance allocations identified in this permit (See 40 CPR 72.84).

b. NOx limits:

1. Pursuant to 40 CFR 76.11, the Division of Air Quality approves a NOx emissions averaging plan for these units. Under the plan, the actual Btu-weighted annual average NOx emission rate for the units in the plan shall be less than or equal to the Btu-weighted annual average NOx emission rate for the same units had they each been operated, during the same period of time, in compliance with the individual applicable emission limitations under 40 CFR 76.5, 76.6, or 76.7, except that for any early election units, the applicable emission limitations shall be under 40 CFR 76.7. If the designated representative demonstrates that the requirement of the prior sentence (as set forth in 40 CFR 76.1 l(d)(l)(ii)(A)) is met for a year under the plan, then this unit shall be deemed to be in compliance for that year with its alternative contemporaneous emission limitation (ACEL) and annual heat input limit. In addition to the described NOx compliance plan, this unit shall comply with all other applicable requirements of 40 CFR part 76, including the duty to reapply for a NOx compliance plan and requirements covering excess emissions.

n. If the designated representative cannot make the above demonstration (as set forth in 40 CFR 76.11 (d)(l )(ii)(A)) for a year under the plan and if a unit fails to meet the annual average alternative contemporaneous emission limitation listed in the table below, or has an annual heat input less than the

Page 71: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001T56 Page 64

amount listed in the table below, then excess emissions of nitrogen oxides occur during the year at this unit. A penalty for excess emissions will be assessed in accordance with 40 CFR 77.6.

Unit ACEL Annual Heat Input Limit

(lb/J:\ID,ffltu) (MMBtu/yr)

BoilerNo.1 0.250 10,341,180

Boiler No. 2 0.250 15,794,280

Boiler No. 3A 0.250 9,331,590

Boiler No. 3B 0.250 9,331,590

Boiler No. 4A 0.250 9,855,000

Boiler No. 4B 0.250 9,855,000

C. Comments, Notes and Justifications - None.

D. Phase II Permit Application and Phase II NOx Compliance Plan (attached)

The permit applications submitted for this facility, as approved by the Division of Air Quality, are part of this pennit. The owners and operators of these Phase II acid rain sources must comply with the standard requirements and special provisions set forth in the following attached applications:

Acid Rain Permit Renewal Application dated April 4, 2018 Phase II NOx Compliance Plan and Averaging Plan dated June 23, 2015

Page 72: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 0 l 001 T56 Page 65

SECTION 3- GENERAL CONDITIONS (version 5.3, 08/21/2018)

This section describes terms and conditions applicable to this Title V facility.

A General Provisions [NCGS 143-215 and 15A NCAC 02Q .0508(i)(l6)] I. Terms not otherwise defined in this permit shall have the meaning assigned to such terms as defined in 15A NCAC

02Dand02Q. 2. The tenns, conditions, requirements, limitations, and restrictions set forth in this pennit are binding and enforceable

pursuant to NCGS 143-215.114A and 143-215.114B, including assessment of civil and/or criminal penalties. Any unauthorized deviation from the conditions of this permit may constitute grounds for revocation and/or enforcement action by the DAQ.

3. This permit is not a waiver of or approval of any other Department permits that may be required for other aspects of the facility which are not addressed in this permit.

4. This permit does not relieve the Pennittee from liability for harm or injury to human health or welfare, animal or plant life, or property caused by the construction or operation of this permitted facility, or from penalties therefore, nor does it allow the Permittee to cause pollution in contravention of state laws or rules, unless specifically authorized by an order from the North Carolina Environmental Management Commission.

5. Except as identified as state-only requirements in this permit, all terms and conditions contained herein shall be enforceable by the DAQ, the EPA, and citiz.ens of the United States as defined in the Federal Clean Air Act

6. Any stationary source of air pollution shall not be operated, maintained, or modified without the appropriate and valid permits issued by the DAQ, unless the source is exempted by rule. The DAQ may issue a permit only after it receives reasonable assurance that the installation will not cause air pollution in violation of any of the applicable requirements. A permitted installation may only be operated, maintained, constructed, expanded, or modified in a manner that is consistent with the tenns of this permit.

B. Permit Availability [15A NCAC 02Q .0507(k) and .0508(i)(9)(B)] The Pennittee shall have available at the facility a copy of this pennit and shall retain for the duration of the permit term one complete copy of the application and any information submitted in support of the application package. The permit and application shall be made available to an authorized representative of Department of Environmental Quality upon request.

C. Severability Clause [ 15A NCAC 02Q .0508(i)(2)] 1n the event of an administrative challenge to a final and binding pennit in which a condition is held to be invalid, the provisions in this permit are severable so that all requirements contained in the pennit, except those held to be invalid, shall remain valid and must be complied with.

D. Submissions [15A NCAC 02Q .0507(e) and 02Q .0508(i)(l6)] Except as otherwise specified herein, two copies of all documents, reports, test data, monitoring data, notifications, request for renewal, and any other information required by this permit shall be submitted to the appropriate Regional Office. Refer to the Regional Office address on the cover page of this permit For continuous emissions monitoring systems (CEMS) reports, continuous opacity monitoring systems (COMS) reports, quality assurance {QA)/quality control (QC) reports, acid rain CEM certification reports, and NOx budget CEM certification reports, one copy shall be sent to the appropriate Regional Office and one copy shall be sent to:

Supervisor, Stationary Source Compliance North Carolina Division of Air Quality 1641 Mail Service Center Raleigh, NC 27699-1641

All submittals shall include the"facility name and Facility ID number (refer to the cover page of this permit).

E. Duty to Comply rl5ANCAC 02Q .0508(i)(3)] The Permittee shall comply with all terms, conditions, requirements, limitations and restrictions set forth in this permit. Noncompliance with any permit condition except conditions identified as state-only requirements constitutes a violation of the Federal Clean Air Act. Noncompliance with any permit condition is grounds for enforcement action, for permit termination, revocation and reissuance, or modification, or for denial of a permit renewal application.

Page 73: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 01001 T56 Page 66

F. Circumvention - STATE ENFORCEABLE ONLY The facility shall be properly operated and maintamed at all times in a manner that will effect an overall reduction in air pollution. Unless otherwise specified by this pennit, no emission source may be operated without the concurrent operation of its associated air pollution control device(s) and appurtenances.

G. Permit Modifications 1. Administrative Permit Amendments [lSA NCAC 02Q .0514]

The Permittee shall submit an application for an administrative permit amendment in accordance with 15A NCAC 02Q .0514.

2. Transfer in Ownership or Operation and Application Submittal Content [I 5A NCAC 02Q .0524 and 02Q .0505] The Permittee shall submit an application for an ownership change in accordance with 15A NCAC 02Q.0524 and 02Q .0505.

3. Minor Permit Modifications [15A NCAC 02Q .0515] The Permittee shall submit an application for a minor permit modification in accordance with 15A NCAC 02Q .0515.

4. Significant Permit Modifications [15A NCAC 02Q .0516] The Permittee shall submit an application for a significant permit modification in accordance with 15A NCAC 02Q .0516.

5. ReopeningforCause[l5ANCAC02Q .0517] The Permittee shall submit an application for reopening for cause in accordance with 15A NCAC 02Q .0517.

H. Changes Not Requiring Permit Modifications 1. Reporting Requirements

Any of the following that would result in new or increased emissions from the emission source{s) listed in Section 1 must be reported to the Regional Supervisor, DAQ: a. changes in the information submitted in the application; b. changes that modify equipment or processes; or c. changes in the quantity or quality of materials processed.

If appropriate, modifications to the permit may then be made by the DAQ to reflect any necessary changes in the permit conditions. In no case are any new or increased emissions allowed that will cause a violation of the emission limitations specified herein.

2. Section 502(b)(l0) Changes [15A NCAC 02Q .0523(a)] a. "Section 502(b)(10) changes" means changes that contravene an express permit term or condition. Such changes

do not include changes that would violate applicable requirements or contravene federally enforceable permit terms and conditions that are monitoring (:including test methods), recordkeeping, reporting, or compliance certification requirements.

b. The Permittee may make Section 502(b)(10) changes without having the permit revised if 1. the changes are not a modification under Title I of the Federal Clean Air Act; 11. the changes do not cause the allowable emissions under the permit to be exceeded; iii. the Permittee notifies the Director and EPA with written notification at least seven days before the change is

made; and iv. the Permittee shall attach the notice to the relevant permit.

c. The written notification shall include: 1. a description of the change; 11. the date on which the change will occur; 111. any change in emissions; and iv. any permit tenn or condition that is no longer applicable as a result of the change.

d Section 502(b )(10) changes shall be made in the penn:it the next time that the permit is revised or renewed, whichever comes first.

3. Off Permit Changes [15A NCAC 02Q .0523(b)] The Permittee may make changes in the operation or emissions without revising the permit if a. the change affects only insignificant activities and the activities remain insignificant after the change; or b. the change is not covered under any applicable requirement.

4. Emissions Trading [15ANCAC 02Q .0523(c)] To the extent that emissions trading is allowed wider ISA NCAC 02D, including subsequently adopted maximum achievable control technology standards, emissions trading shall be allowed without permit revision pursuant to 15A NCAC02Q .0523(c).

Page 74: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 0I00IT56 Page 67

I.A Reporting Requirements for Excess Emissions and Permit Deviations [15A NCAC 02D .0535(£) and 02Q .0508(t)(2)] ''Excess Emissions" - means an emission rate that exceeds any applicable emission limitation or standard allowed by any rule in Sections .0500, .0900, .1200, or .1400 ofSubchapter 02D; or by a pennit condition; or that exceeds an emission limit established in a permit issued under 15A NCAC 02Q .0700. (Note: Definitions of excess emissions under 02D .1110 and O2D . 111 I shall apply where defined by rule.)

"Deviations" - for the purposes of this condition, any action or condition not in accordance with the terms and conditions of this permit including those attributable to upset conditions as well as excess emissions as defined above lasting less than four hours.

Excess Emissions I. If a source i<i required to report excess emissions under NSPS ( 15A NCAC 02D .0524), NESHAPS (15A NCAC 02D

.1110 or .1111 ), or the operating permit provides for periodic (e.g., quarterly) reporting of excess emissions, reporting shall be performed as prescribed therein.

2. If the source is not subject to NSPS (15A NCAC 02D .0524), NESHAPS (15A NCAC 02D .1110 or .1111), or these rules do NOT define "exces..<; emissions," the Permittee shall report excess emissions in accordance with 15A NCAC 02D .0535 as follows: a. Pursuant to 15A NCAC 02D .0535, if excess emissions last for more than four hours resulting from a malfunction,

a breakdown of process or control equipment, or any other abnormal condition, the owner or operator shall: i. notify the Regional Supervisor or Director of any such occurrence by 9 :00 a.m. Eastern Time of the Division's

next business day of becoming aware of the occurrence and provide: • name and location of the facility; • nature and cause of the malfunction or breakdown; • time when the malfunction or breakdown is first observed; • expected duration; and • estimated rate of emissions;

ii. notify the Regional Supervisor or Director immediately when corrective measures have been accomplished; and

iii. submit to the Regional Supervisor or Director within 1 S days a written report as described in 15A NCAC 02D .0535(f)(3).

Permit Deviations 3. Pursuant to 15A NCAC 02Q .0508(f)(2), the Pennittee shall report deviations from permit requirements (terms and

conditions) as follows: a. Notify the Regional Supervisor or Director of all other deviations from pennit requirements not covered under

15A NCAC 02D .0535 quarterly. A written report to the Regional Supervisor shall include the probable cause of such deviation and any corrective actions or preventative actions taken. TI1e responsible official shall certify all deviations from permit requirements.

I.B Other Requirements under 15A NCAC 02D .0535 The Permittee shall comply with all other applicable requirements contained in 15A NCAC 02D .0535, including 15A NCAC 02D .0535(c) as follows: I. Any excess emissions that do not occur during start-up and shut-down shall be considered a violation of the appropriate

rule unless the owner or operator of the sources demonstrates to the Director, that the excess emissions are a result of a malfunction. The Director shall consider, along with any other pertinent information, the criteria contained in 15A NCAC 02D .053S(c)(l) through (7).

2. 15A NCAC 02D .0535(g). Excess emissions during start-up and shut-down shall be considered a violation of the appropriate rule if the owner or operator cannot demonstrate that excess emissions are unavoidable.

J. Emergency Provisions [40 CFR 70.6(g)] The Permittee shall be subject to the following provisions with respect to emergencies: 1. An emergency means any situation arising from sudden and reasonably unforeseeable events beyond the control of the

facility, including acts of God, which situation requires immediate corrective action to restore normal operation, and that causes the facility to exceed a technology-based emission limitation under the permit, due to unavoidable increases in emissions attributable to the emergency. An emergency shall not include noncompliance to the extent caused by improperly designed equipment, lack of preventive maintenance, careless or improper operation, or operator error.

Page 75: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air QualityPennit No. 01001T56

Page 68

2. An emergency constitutes an affirmative defense to an action brought for noncompliance with such technology-based emission limitations if the conditions specified in 3. below are met

3. The affirmative defense of emergency shall be demonstrated through properly signed contemporaneous operating logs or other relevant evidence that include information as follows: a. an emergency occurred and the Permittee can identify the cause( s) of the emergency; b. the permitted facility was at the time being properly operated; c. during the period of the emergency the Permittee took all reasonable steps to minimize levels of emissions that

exceeded the standards or other requirements in the permit; and d. the Permittee submitted notice of the emergency to the DAQ within two working days of the time when emission

limitations were exceeded due to the emergency. This notice must contain a description of the emergency, steps taken to mitigate emissions, and corrective actions taken.

4. In any enforcement proceeding, the Permittee seeking to establish the occurrence of an emergency has the burden of proof.

5. This provision is in addition to any emergency or upset provision contained in any applicable requirement specified elsewhere herein.

K. Permit Renewal [15A NCAC 02Q .0508(e) and 02Q .0513(b)] This 15A NCAC 02Q .0500 permit is issued for a fixed term not to exceed five years and shall expire at the end of its term. Permit expiration terminates the facility's right to operate unless a complete ISA NCAC 02Q .0500 renewal application is submitted at least six months before the date of permit expiration. If the Pennittee or applicant has complied with ISA NCAC 02Q .0512(b)(l), this 15A NCAC 02Q .0500 permit shall not expire until the renewal permit has been issued or denied. Permit expiration under 15A NCAC 02Q .0400 tenninates the facility's right to operate unless a complete 15A NCAC 02Q .0400 renewal application is submitted at least six months before the date of permit expiration for facilities subject to ISA NCAC 02Q .0400 requirements. In either of these events, all terms and conditions of these pennits shall remain in effect until the renewal pennits have been issued or denied.

L. Need to Halt or Reduce Activity Not a Defense [ 15A NCAC 02Q .0508(i)( 4)] It shall not be a defense for a Permittee in an enforcement action that it would have been necessruy to halt or reduce the pennitted activity in order to maintain compliance with the conditions of this permit.

M. Dutv to Provide J.nformation (submittal of information) [ISA NCAC 02Q .0508(i)(9)] 1. The Permittee shall furnish to the DAQ, in a timely manner, any reasonable information that the Director may request

in writing to determine whether cause exists for modifying, revoking and reissuing, or terminating the permit or to determine compliance with the permit.

2. The Permittee shall furnish the DAQ copies of records required to be kept by the permit when such copies are requested by the Director. For information claimed to be confidential, the Permittee may furnish such records directly to the EPA upon request along with a claim of confidentiality.

N. Duty to Supplement [15A NCAC 02Q .0507(f)] The Pennittee, upon becoming aware that any relevant facts were omitted or incorrect infonnation was submitted in the permit application, shall promptly submit such supplementary facts or corrected information to the DAQ. The Pennittee shall also provide additional information as necessary to address any requirement that becomes applicable to the facility after the date a complete permit application was submitted but prior to the release of the draft permit.

0. Retention of Records [1 SA NCAC 02Q .0508(f) and 02Q .0508 (1)] The Pennittee shall retain records of all required monitoring data and supporting information for a period of at least five years from the date of the monitoring sample, measurement, report, or application. Supporting information includes all calibration and maintenance records and all original strip-chart recordings for continuous monitoring information, and copies of all reports required by the permit. These records shall be maintained in a form suitable and readily available for expeditious inspection and review. Any records required by the conditions of this permit shall be kept on site and made available to DAQ personnel for inspection upon request.

P. Compliance Certification [15A NCAC 02Q .0508(n)] The Permittee shall submit to the DAQ and the EPA (Air and EPCRA EnforcementBranch, EPA, Region 4, 61 Forsyth Street SW, Atlanta, GA 30303) postmarked on or before March 1 a compliance certification (for the preceding calendar year) by a responsible official with all federally-enforceable tenns and conditions in the permit, including emissions limitations, standards, or work practices. It shall be the responsibility of the current owner to submit a compliance certificl!-tion for the entire year regardless of who owned the facility during the year. The compliance ce1tification shall

Page 76: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pennit No. 01001 T56 Page 69

comply with additional requ.rrements as may be specified under Sections l l4(a)(3) or 504(b) of the Federal Clean Air Act. The compliance certification shall specify: 1. the identification of each term or condition of the permit that is the basis of the certification; 2. the compliance status ( with the tenns and conditions of the permit for the period covered by the certification); 3. whether compliance wa.-. continuous or intermittent; and 4. the method(s) used for determining the compliance status of the source during the certification period.

Q. Certification by Responsible Official [15A NCAC 02Q .0520J A responsible official shall certify the truth, accuracy, and completeness of any application form, report, or compliance certification required by this permit. All certifications shall state that based on information and belief formed after reasonable inquiry, the statements and information in the document are true, accurate, and complete.

R. Permit Shield fo1· Applicable Requirements [15A NCAC 02Q .0512]. 1. Compliance with the terms and conditions of this permit shall be deemed compliance with applicable requirements,

where such applicable requirements are included and specifically identified in the permit as of the date ofpennit issuance.

2. A pennit shield shall not alter or affect: a. the power of the Commission, Secretary of the Department, or Governor under NCGS 143-215.3(a)(12), or EPA

under Section 303 of the Federal Clean Air Act; b. the liability of an owner or opera.tor of a facility for any violation of applicable requirements prior to the effective

date of the pennit or at the time of permit issuance; c. the applicable requirements under Title N; or d. the ability of the Director or the EPA under Section 114 of the Federal Clean Air Act to obtain information to

determine compliance of the facility with its permit. 3. A permit shield does not apply to any change made at a facility that does not require a pennit or permit revision made

under 15A NCAC 02Q .0523. 4. Apennit shield does not extend to rninorpennitmodi:fications made under 15A NCAC 02Q .0515.

S. Termination, Modification. and Revocation of the Permit [ 15A NCAC 02Q .0519] The Director may terminate, modify, or revoke and reissue this permit if: 1. the information contained in the application or presented in support thereof is determined to be incorrect; 2. the conditions under which the permit or pennit renewal was granted have changed; 3. violations of conditions contained in the permit have occurred; 4. the EPA requests that the permit be revoked under 40 CFR 70.7(g) or 70.8(d); or 5. the Director finds that termination., modification, or revocation and reissuance of the permit is necessary to carry out the

purpose ofNCGS Chapter 143, Article 21B.

T. Insignificant Activities [15A NCAC 02Q .0503] Because an emission source or activity is insignificant does not mean that the emission source or activity is exempted from any applicable requirement or that the owner or operator of the source is exempted from demonstrating compliance with any applicable requirement. The Permittee shall have available at the facility at all times and made available to an authorized representative upon request, documentation, including calculations, if necessary, to demonstrate that an emission source or activity is insignificant.

U. Property Rights [15A NCAC 02Q .0508(i)(8)] This permit does not convey any property rights in either real or personal property or any exclusive privileges.

V. Inspection and Entrv [ 15A NCAC 02Q .0508(1) and NCGS 143-215.3(a)(2)] 1. Upon presentation of credentials and other documents as may be required by law, the Pennittee shall allow the DAQ,

or an authorized representative, to perform the following: a enter the Permittee's premises where the permitted facility is located or emissions-related activity is conducted, or

where records are kept wider the conditions of the permit; b. have access to and copy, at reasonable times, any records that are required to be kept under the conditions of the

permit; c. inspect at reasonable times and using reasonable safety practices any source, equipment (including monitoring and

air pollution control equipment), practices, or operatiom; regulated or required under the pennit; and d. sample or monitor substances or parameters, using reasonable safety practices, for the purpose of assuring

compliance with the permit or applicable requirements at reasonable times.

Page 77: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 01001 T56 Page 70

Nothing in this condition shall limit the ability of the EPA to inspect or enter the premises of the Permittee under Section 114 or other provisions of the Federal Clean Air Act.

2. No person shall refuse entry or access to any authorized representative of the DAQ who requests entry for purposes of inspection, and who presents appropriate credentials, nor shall any person obstruct, hamper, or interfere with any such authorized representative while in the process of carrying out his official duties. Refusal of entry or access may constitute ground<; for permit revocation and assessment of civil penalties.

W. Annual Fee Payment [15A NCAC 02Q .0508(i)(lO)J 1. The Pennittee shall pay all fees in accordance with 15A NCAC 02Q .0200. 2. Payment of fees may be by check or money order made payable to the N.C. Department of Environmental Quality.

Annual pennit fee payments shall refer to the pennit number. 3. If, within 30 days after being billed, the Pennittee fails to pay an annual fee, the Director may initiate action to

terminate the permit under 15A NCAC 02Q .0519.

X. Annual Emission Inventorv Requirements [15A NCAC 02Q .0207] The Pennittee shall report by June 30 of each year the actual emissions of each air pollutant listed in 15A NCAC 02Q .0207(a) from each emission source within the facility during the previous calendar year. The report shall be in or on such fonn as may be established by the Director. The accuracy of the report shall be certified by a responsible official of the facility.

Y. Confidential Information [15ANCAC 02Q .0107 and02Q. 0508(i)(9)] Whenever the Pennittee submits information under a claim of confidentiality pursuant to 15A NCAC 02Q .0 I 07, the Permittee may also submit a copy of all such infunnation and claim directly to the EPA upon request. All requests for confidentiality must be in accordance with 15ANCAC 02Q .0107.

Z. Construction and Operation Permits [15A NCAC 02Q .0100 and .0300] A construction and operating pennit shall be obtained by the Pennittee for any proposed new or modified facility or emission source which is not exempted from having a pennit prior to the beginning of construction or modification, in accordance with all applicable provisions of 15A NCAC 02Q .0100 and .0300.

AA. Standard Application Form and Required Information [ISANCAC 02Q .0505 and .0507] The Pennittee shall submit applications and required information in accordance with the provisions of 15A NCAC 02Q .0505 and .0507.

BB. Financial Responsibilitv and Compliance ffistory [15A NCAC 02Q .0507(d)(4)] The DAQ may require an applicant to submit a statement of financial qualifications and/or a statement of substantial compliance history.

CC. Refrigerant Requirements (Stratospheric Ozone and Climate Protedion) fl5A NCAC 02Q .0501(e)] 1. If the Permittee has appliances or refrigeration equipment, including air conditioning equipment., which use Class I or II

ozone-depleting substances such as chlorofluorocarbons and hydrochlorofluorocarbons listed as refrigerants in 40 CFR Part 82 Subpart A Appendices A and B, the Permittee shall service, repair, and maintain such equipment according to the work practices, personnel certification requirements, and certified recycling and recovery equipment specified in 40 CFR Part 82 Subpart F.

2. The Permittee shall not knowingly vent or otherwise release any Class I or II substance into the environment during the repair, servicing, maintenance, or disposal of any such device except as provided in 40 CFR Part 82 Subpart F.

3. The Pennittee shall comply with all reporting and recordkeeping requirements of 40 CFR 82.166. Reports shall be submitted to the EPA or its designee as required.

DD. Prevention of Accidental Releases - Section 112(r) (15A NCAC 02Q .0508(h)] If the Permittee is required to develop and register a Risk Management Plan with EPA pursuant to Section l l 2(r) of the Clean Air Act, then the Pennittee is required to register this plan in accordance with 40 CFR Part 68.

EE. Prevention of Accidental Releases General Duty Clause - Section 112(r)(l) - FEDERALLY-ENFORCEABLE ONLY Although a risk management plan may not be required, if the Pennittee produces, processes, handles, or stores any amount of a listed hazardous substance, the Permittee has a general duty to talce such steps as are necessary to prevent the accidental release of such substance and to minimize the consequences of any release.

Page 78: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 0 l 001 T56 Page 71

FF. Title IV Allowances [15A NCAC 02Q .0508(i)(l)] This permit does not limit the number of Title IV allowances held by the Permittee, but the Pennittee may not use allowances as a defense to noncompliance with any other applicable requirement The Pennittee's emissions may not exceed any allowances that the facility lawfully holds under Title IV of the Federal Clean Air Act.

GG. Air Pollution Emergency Episode [15A NCAC 02D .0300J Should the Director of the DAQ declare an Air Pollution Emergency Episode, the Permittee will be required to operate in accordance with the Permittee's previously approved Emission Reduction Plan or, in the absence of an approved plan, with the appropriate reqwrements specified in 15A NCAC 02D .G300.

HH. Registration of Air Pollution Sources [15ANCAC 02D .0202] The Director of the DAQ may require the Permittee to register a source of air pollution. If the Pennittee is required to register a source of air pollution, this registration and required information will be in accordance with 15A NCAC 02D .0202(b).

II. Ambient Air Oualitv Standards [I SA NCAC 02D .050l{c)] In addition to any control or manner of operation necessary to meet emission standards specified in this permit, any source of air pollution shall be operated with such control or in such manner that the source shall not cause the ambient air quality standards in 15 A NCAC 02D .0400 to be exceeded at any point beyond the premises on which the source is located. When controls more stringent than named in the applicable emission standards in this pennit are required to prevent violation of the ambient air quality standards or are required to create an offset, the permit shall contain a condition requiring these controls.

JJ. General Emissions Testing and Reporting Requirements [15A NCAC 02Q .0508(i)(l6)] Emission compliance testing shall be by the procedures of Section .2600, except as may be otherwise required in Rules .0524, .0912, .ll 10, .1111, or .1415 of Subchapter 02D. If emissions testing is required by this permit or the DAQ orifthe Pennittee submits emissions testing to the DAQ to demonstrate compliance, the Pennittee shall perform such testing in accordance with 15A NCAC 02D .2600 and follow the procedures outlined below: 1. The owner or operator of the source shall arrange for air emission testing protocols to be provided to the Director

prior to air pollution testing. Testing protocols are not required to be pre-approved by the Director prior to air pollution testing. The Director shall review air emission testing protocols for pre-approval prior to testing if requested by the owner or operator at least 45 days before conducting the test.

2. Any person proposing to conduct an emissions test to demonstrate compliance with an applicable standard shall notify the Director at least 15 days before beginning the test so that the Director may at his option observe the test.

3. The owner or operator of the source shall arrange for controlling and measuring the production rates during the period of air testing. The owner or operator of the source shall ensure that the equipment or process being tested is operated at the production rate that best fulfills the purpose of the test. The individual conducting the emission test shall describe the procedures used to obtain accurate process data and include in the test report the average production rates determined during each testing period.

4. Two copies of the final air emission test report shall be submitted to the Director not later than 30 days after sample collection unless otherwise specified in the specific conditions. The owner or operator may request an extension to submit the final test report. The Director shall approve an extension request ifhe finds that the extension request is a result of actions beyond the control of the owner or operator. a. The Director shall make the final determination regarding any testing procedure deviation and the validity of the

compliance test. The Director may: i. Allow deviations from a method specified under a rule in this Section if the owner or operator of the source

being tested demonstrates to the satisfaction of the Director that the specified method is inappropriate for the source being tested.

11. Prescribe alternate test procedures on an individual basis when he finds that the alternative method is necessary to secure more reliable test data.

iii. Prescribe or approve methods on an individual basis for sources or pollutants for which no test method is specified in this Section if the methods can be demonstrated to determine compliance of permitted emission sources or pollutants.

b. The Director may authorize the Division of Air Quality to conduct independent tests of any source subject to a rule in this Subchapter to determine the compliance status of that source or to verify any test data submitted relating to that source. Any test conducted by the Division of Air Quality using the appropriate testing procedures described in Section 02D .2600 has precedence over all other tests.

Page 79: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Permit No. 0100 I T56 Page 72

KK. Reopening for Cause [15A NCAC 02Q .0517) l. A pennit shall be reopened and revised under the following circumstances:

a. additional applicable requirements become applicable to a facility with remaining permit term of three or more years;

b. additional requirements (including excess emission requirements) become applicable to a source covered by Title IV;

c. the Director or EPA finds that the permit contains a material mistake or that inaccurate statements were made in establishing the emissions s1andards or other tenns or conditions of the pennit; or

d. the Director or EPA determines that the permit must be revised or revoked to assure compliance with the applicable requirements.

2. Any permit reopening shall be completed or a revised permit issued within 18 months after the applicable requirement is promulgated. No reopening is required if the effective date of the requirement is after the expiration of the pennit term unless the term of the permit was extended pursuant to 15A NCAC 02Q .0513 ( c ).

3. Except for the state-enforceable only portion of the permit, the procedures set out in 15ANCAC 02Q .0507, .0521, or .0522 shall be followed to reissue the permit. If the State-enforceable only portion of the permit is reopened, the procedures in 15A NCAC 02Q .0300 shall be followed. The proceedings shall affect only those parts of the pennit for which cause to reopen exisl'l.

4. The Director shall notify the Permittee at least 60 days in advance of the date that the permit is to be reopened, except in cases of imminent threat to public health or safety the notification period may be less than 60 days.

5. Within 90 days, or 180 days if the EPA extends the response period, after receiving notification from the EPA that a permit needs to be terminated, modified, or revoked and reissued, the Director shall send to the EPA a proposed determination of termination, modification., or revocation and reissuance, as appropriate.

LL. Reporting Requirements for Non-Operating Equipment [15A NCAC 02Q .0508(i)(16)] The Pennittee shall maintain a record of operation for permitted equipment noting whenever the equipment is taken from and placed into operation. When permitted equipment is not in operation, the requirements for testing, monitoring, and recordkeeping are suspended until operation resumes.

:MM. Fu!!itive Dust Control Requirement [15A NCAC 02D .0540) As required by 15A NCAC 02D .0540 "Particulates from Fugitive Dust Emission Sources," the Permittee shall not cause or allow fugitive dust emissions to cause or contnbute to substantive complaints or excess visible emissions beyond the property boundary. If substantive complaints or excessive fugitive dust emissions from the facility are observed beyond the property boundaries for six minutes in any one hour (using Reference Method 22 in 40 CFR. Appendix A), the owner or operator may be required to submit a fugitive dust plan as described in 02D .0540(f).

"Fugitive dust emissions" means particulate matter from process operations that does not pass through a process stack or vent and that is generated within plant property boundaries from activities such as: unloading and loading areas, process areas, stockpiles, stock pile working, plant parking iots, and plant roads (including access roads and haul roads).

NN. Specific Permit Modifications [15A NCAC 02Q .0501 and .0523) 1. For modifications made pursuant to I SA NCAC 02Q .0501(c)(2), the Permittee shall file a Title V Air Quality Permit

Application for the air emission source(s) and associated air pollution control device(s) on or before 12 months after commencing operation.

2. For modifications made pursuant to 15A NCAC 02Q .050l(d)(2), the Permittee shall not begin operation of the air emission source(s) and associated air pollution control device(s) until a Title V Air Quality Pennit Application is filed and a construction and operation permit following the procedures of Section .0500 (except for Rule .0504 of this Section) is obtained.

3. For modifications made pursuant to 502(b)(10), in accordance with 15A NCAC 02Q .0523(a)(l)(C), the Pennittee shall notify the Director and EPA (EPA - Air Planning Branch, 61 Forsyth Street SW, Atlanta, GA 30303) in vmting at least seven days before the change is made. The vmtten notification shall include: a. a description of the change at the facility; b. the date on which the change will occur; c. any change in emissions; and d. any permit term or condition that is no longer applicable as a result of the change.

In addition to this notification requirement, with the next significant modification or Air Quality Permit renewal, the Pennittee shall submit a page "E5" of the application forms signed by the responsible official verifying that the

Page 80: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Air Quality Pem1it No. 01001 T56 Page 73

application for the 502(b )(10) change/modification, is true, accurate, and complete. Further note that modifications made pursuant to 502(b ){l 0) do not relieve the Permittee from satisfying preconstruction requirements.

00. Third Partv Participation and EPA Review [l5ANCAC 02Q .0521, .0522 and .0525(7)] For pennits modifications subject to 45-day review by the federal Environmental Protection Agency (EPA), EPA' s decision to not object to the proposed pennit is considered final and binding on the EPA and absent a third party petition, the failure to object is the end ofEP A's decision-making process with respect to the revisions to the permit. The lime period available to submit a public petition pursuant to 15A NCAC 02Q .0518 begins at the end of the 45-day EPA review period.

Page 81: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

AOS ~ACT Btu CAA CSAPR CEM CFR DAQ DEQ EMC EPA FR GACT HAP MACT NAA NCAC NCGS NESHAP NOx NSPS OAH PM PM10 POS PSD RACT SIC SIP S02 tpy voe

Attachment 1 to Air Quality Permit O l 001 T56 Duke Energy Progress, LLC - Roxboro Steam Electric Plant

List of Acronyms

Alternative Operating Scenario Best Available Control Technology British thermal unit Clean Air Act Cross State Air Pollution Rule Continuous Emission Monitor Code of Federal Regulations Division of Air Quality Department of Environmental Quality Environmental Management Commission Environmental Protection Agency Federal Register Generally Available Control Technology Haz.ardous Air Pollutant Maximum Achievable Control Technology Non-Attainment Area North Carolina Administrative Code North Carolina General Statutes National Emission Standards for Hazardous Air Pollutants Nitrogen Oxides New Source Perfonnance Standard Office of Administrative Hearings Particulate Matter Particulate Matter with Nominal Aerodynamic Diameter of 10 Micrometers or Less Primary Operating Scenario Prevention of Significant Deterioration Reasonably Available Control Technology Standard Industrial Classification State hnplementation Plan Sulfur Dioxide Tons Per Year Volatile Organic Compound

Page 82: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Attachment 2 to Air Quality Permit O 1001 T56 Duke Energy Progress, LLC - Roxboro Steam Electric Plant

Phase II Acid Rain Permit Renewal Application and NOx Averaging Plan

(Dated April 4, 2018) (Eight pages)

Page 83: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

&EPA

STEP1

Identity the reality name, Slate, and plant (ORIS) code.

STEP2

Enter the unltlot far ewry affaclad unit at U,a affaoted source in column -S."

Acid Rain Permit Application

TNtl&lhmlHIDnla: D New D RwlHd X forA~pennllNn111al

a

Unit ID#

1

2

3A

3S

4A

-4B

.

PllntCode: 2712

b

Unit w~ Hold Allowances ii Amlrd!l a With 40 CFR 7Z.!l(c)(1)

Yes

YM

Yes

Ym

Yes

Vas

Page 84: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

STEP3

Reed the standard requirements:

Duke Enmgy Prograu, UC ~ R0XbafD stD8m Eledric Plani

Facllitv {Soun;e) Name l&om STEP 1)

Permit Bequiremants

Page2

(1) "the designated repr~entative of each affected source and each affected unit at the source shall:

(i) Submit a complete Acid Rain penriit application (including a compliance plan} under 40 CFR part 72 in accordance with the deadNnes specified rn 40 CFR 72-30; and · . - . (IQ Submit In a· 6rnely manner any supplemental information that the permitting authorJty detennines is necessary.in order to review an Acid Rain permit application and issue or deny in Acid Rain pemiit: _

(2) The owners and operators of each affected source and each affected unit at the source shall: · .

(0 Operate the unit In compliance with a complete Acid Rain permit application or a superseding Acid Rain pem,it Issued by the permitting authority; and {ii) Have an Acid Rain Permit.

Monltoiing Requirements

(1) The owners and operators .and, to the extent applicable, designated representative of each affected source and each affected unit at the source shall comply with the monitoring requirements as provided in 40 CfR part 75. . · . . . _ (2) The emisslons measu~rnents recor~ed a_nd report~d in accordance with 40 CFR part 75 shell be used to deterrmne compNance by the source or unit, as ·appropriate, with the Acid Rarn emissions Hmltatlons and emissions reduction requirements for sulfur dioxide and nitrogen oxides under the Acid Rain Program. _ · · : (3) The requirements of 40 CFR part 75 shalt not affeot the responsibility of fhe owners and ~ to monitor emlesicns of other pollutants or ofher emissions characteristics at the unit under other appli~bfe requirements or the Act and other provisions of the ~rating pe.rrmt for the source.

Sulfur Dioxide Requirements

{1) lhe owners and operaton of each source and each affected unit at the ~~~~ ·- . .

(i) Hoid allowances, as of the al!owaooe transfer deadline~-in the squrce's compliance account (a~r peductlons u~~ 40 CFR 73.~(c)), not 1,ss thari the total annual em1ss10ns of sulfur cli.oxide for the previ_ous ca"ndar ):ear rrom the affected units at the source; and - · . . ·. ·. · · (i_i) CQmply wlth the applicable Acid-Rain ernifSlons limJtations forsutfur dioxide.. . : . . - . . .. ·._ . · •. . . . · ..

(2) Each ton of sulfur dto>dde emitted in excess of.the Acid Rain e·missions llmitaljans ~r_suiftir dioxide sha~I constitute a separate violation of the Ari.._· (3) An ~ urit shaft !Je subJect to the requirements under pa~ph (1) of the sulfur d10xide requrrements a.~ foffows: · .· · . _ - · . · . . · . . ·

(I) Staomg January 1~ 2000, an affected unit -.,nder 40 CFR 72.6(a)(2); or (Ii} Starting · on the tater of January 1, 2000 or the deadline: for monitor certificatt0n under 40 CFR part · 75, · an alfeeted unit under 40 CFR 72.6(a)(3). · · · · · ·

l:PA FOffl'l 7111J.16 ~ 7-2014)

Page 85: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

I """'.,,_,..,..., LLC· -- EIOClrlcl'llnl Fdty (Source} Name (!ram STEP 1)

Sulfur Dioxide Beauirements. Cont'd.

Page3

(4} Allowances shall be held In, deducted from, ·or transferred among Allowance Tracking System accounts in accordance with the Acid Rain Program. (5) · An allowance shall not be deducted in order to comply with the requirements under paragraph (1) of the sulfur dioxide requirements prior to the calendar year for which the aOowanca waa allocated. _ (6) An allowance allocated by the Administrator under the Acid Rain Program {s a lmited authorizatian to emit sulfur dioxide in accordance Wlh the Acid Rain Program. No provision of lhe Ackt RaJn Program. the Acid Rain permit application1 the Acid Rain pennit, or an exen,ptlon under 40 CFR 72. 7 or.72.8 and no pro\llsfon of law shall be construed to limlt the authority of the United States to tenninate or llmlt &UCih authorization. (7) An aflowance allocated by the Administrator under th& Acid Rain Program does not constitute a property· right.

Nitrogen Oxides Requirements

The owner$ and operators of the source and eacti affected unit at the source shall comply with the appHcable Acid Rain emissions limitation for nitrogen oxides.

§xcess Emissions Regurt,menta (1) The designated representative of an aff~ aourc• that hai excega emjssions in any calendar year shall submit a proPosed offset plan, as required under 40 CFR part Tf. . (2) The owners and operators of an affected source that has e~ceas em.i-1ons in any calendar year shaU: . · _.

(0 Pay w~hout demand the penalty required, and pay upon demand the Interest on thal penalty. as reqtiirai by 40 CFR part 77; and · . (ii). Comply· ·with the terms of a11 approved offset plan, as required by 40 CFR part 77. .

Recordkeeping and Reporting Requirements

(.1) Unless otherwise provided~ the ownei& and operators af_the source ·and each affec•d unit at the fC)urce ehaU keep on site at 1he source each of the following doellments for a period of~ yeara.ftom the date the dc>Qument is created. T~ia ~ may ~ ext~nde~ tor ~use, !it. any time poor to the end of5 years, in•writfng byfheAdminlstratororpem.1~g . . . .. ~uthority: · - _ · . . . . . . . .. . · · -· · . · · · . . . . ..

. {i) _Jhe cettifacate of ~senta~cm for.the d~lgnated ,.presentattv, for · the source.and each affected unit et the source and all document& that demohstiate the truth of the stateinerita In the certificate of representation, ' ilJ a~a~ ~ -40 fFR 72.24; ·pro~ed _that the -~e:and documents shall be retained on site at the source beyond sijch &--year. peri_od until such documents are super·s~ because Qf the submission

EPA FG!ftl 7110-18 (Aevised 7-2014)

Page 86: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Duka Enargy Pragress. L\.C • ftctboro Steam Electrte PIJnt

Facllltv lSowtel Name (rtom STEP 11

Page4

of a ne~ . . certificate cf representation changing 1he designated representative:

STEP 3, Cont'd. Recordkeepinp and Reporting Requirements, Copt'd.

(ii) All emissions monitoring lnfonnation,· In accordance with 40 CFR part 75, provided that to the extent that 40 CFR part 75 provtdes for a 3&year period for recordkeeping, the 3--year period shall apply. . · (iii) Copies of all repor1s, compliance certifications. and other submissions and all records made or required under the Acid Rain Ps:oqram; and, (iv) COplaa of all documents used to cornpfete an Acid Rain permit applfcation and anY. other submission under the Acid Rain Program or to demonstrate compliance with lhe requirements of the Acid Rain Program.

(2) The d11$ignated representative of an affected source and each affected unit at the source shall submit ~ reports and compliance certifications required under the Acid Rain Program, including thos~ under 40 CFR part 72 subp~rt 1 and 40 CFR part 75.

Liablllty

(1) Any penso~ who knowingly violates any requirement or prohibition of the Acid Rain Program, a complete Acid Rain permtt application, an Acid Raln permit, · or an exemption under 40 CFR 72. 7 er 72.8, · including any requirement for the payment of any penally owed lo the Un~ States, shall be subject tQ enforcement pursuant to section 113(0) of the Ad. (2) Any person who knowingly makes a false, material statement in any record, submfsslon, or report under the Acid Rain Program shall be subject to criminal enforcement pursuant to section 113(c) of the Act and 18 u.s.c. 1001. · . (3) No permit revision shan excuse any violation of the requirements of the Acid Rain Program that occura prior to the date tha1 the revision takes effect (4) Each affected source and each affected unit shall meet the requirements of the Acid Rai!i Pmgram. · . · . (5) Any provision of the Add Rain Program that applies to an affected aourte (incr~ding a provision appli~ble to · the d~lgnate,d rep,r~s-tlve ot. ~n affected source) shaR also apply to the owners and operators of such source and of the affected units at the source. . · .· . (6) Any provision of~ Aci? Rain Program_ t~~t. appliea to an aff~cted unit (Including a · provi&1m1 applicable to the desagnated · representatwe Df an £tffected unit) ~halt also apP,IY to the c:,wners a~ operators of ~uch ~nit. {7) E~ch vlofat•~~ ~ a provtSlon of 40 CfR parts 72, 73, 74, 75,. 76, 77, ~nd 78 by an affected source or affected untt. or by an owner or operator or designated represen1ative of stich ·source or· untt. shaD ·be a separate violation of the Act. · ·

Effect on Other Authgrltlp

No provision of the Acid Rain Program, an Acid ,Rain permit apJ)li~ation, an A~d Rain pennft. or an exemption under 40 CFR 72.7 or 12.a·shall be construed as: · · : · . . .·: · · · . . (1) Except as express!Y provided in tffle IV of the Act. exempting or excluding the· owners ~~d operators . and. to the extent applicable, the · designated representative of an affected source ·Of affected unit from compliance with

EPA FOim 1610-18 (RIJ'lilad 7-mi 4)

Page 87: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

STEP 3, Cont'd.

STEP4 Readlhe certlflcalion statement, sign, and date.

Duke Energy Progralis, l.L.C • RaxlxlR, $taam Electric ~lllnt

Fact!itv (SOO!a!l Name (from STEP 11

Pages

any other provision of the Act, inc1ud;ng the p,ovfsions of title I of the Act relating · ·

Eff§Cf on other {\uthoritfes. Cont'd.

to applicable National Ambie11t Air QuaUty Standards or State Implementation Plans; (2).Llmltlng the number of aaowances a source can hold; provided, that the numbe_r of anowances held by th$. s~urce shall not affect the source's obfigatIon to comply with any other provasions of the Act; . . (3) Requiring a change of any kind many State faw regulating electric utiflty ra1es and charges. affecting any Stat• law regarding such state regulation, or limiting such StalG regulation, including any prudence review requlremems under such State law; . . (4) Modifying the Federal Power Act Qf affecting the authority of the Federal Energy Regulatory Commission under the Federal Power Aot or; (5) Interfering with or impairing any program for competitive bidding for power supply in a state in which such program Is egtabllshed.

Certtftcation I ani authorized to make this submission on behalf of the owners and operators of the affected source or affeclr;td units f-0r which the submiS&i9n is made; I cerUfy under penalty of law that l have personal~ examined, ~d am familiar with, the statements and lnfonnatlon submitted 1n 1hla documant and all its attachments: .Based on my Inquiry of those Individuals with primary responsibiLity for obtaining the information, I certify that the statemen,S and information are to the best of my knowledge and belief true, accurate, and complete. 1· am aware that there are significant penalties for submitting fafse statements and into·rmation or omittin~ required statements and infonnation, including fhe possibility of fine or impnsonment.

Name Steve Immel VP CaroUnas Coal Generation

Date c4 o4

Received

APR 13 201!

Air PermHs Section

EPA. Flllffll 7610-16 tR....i.ed 7~14)

Page 88: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Unit•d State~ Env/ninmental F'totecllon Agency

&EPA ~~;d'Rain NOx Averaging Plan

0MB No. 2IJI0.02$8 Appioval upires 111311/201 ~

STEP 1

ldlilntlfy the units participating 11'1 this averaging plan b v plant name, State, and unit ID. In column (a), fill in eac.h unit's applicable emlQion limltatitm from 40 CFR 76.5, 78.6, or 76.7. In column (b)1 assign an altematlve contemporaneous annual emissions !Imitation (ACEL) in lblmmBtu to each unit, In co,Jumn (c), assign an annllal heat Input llmltatlon Jn mmBtu 10 each unit. Continue to page 3 if necessary.

SlEP2

USe the formula to enter the Btu-welghtfd annual emission rate averaged over the units If lhey an! opereted in acc:ordanc, wlfh the proposed averaging plan and the Btu-weighted annual average emission rate for the same units .if tbe:i, are operated in c;ompllance with 40 CFR 76,5, T6.6, <1r 78.7. The former must be less th.-in or equal to the hatter.

For more irifonnatlon, see Instructions and refer to 40 CFR 76.11

This submission fs: • New X Revised

Page 1

Page 1 of-3

(a) Emission

(b) (c)

Plant Name State Unit ID# UmitatiOO ACEI.. L' "t Annua Heat nout rm1

Belews Creek NC 1

Bele-ws Creek NC 2

Cliffside NC 5

G G Allen I

NC 1

G G Allen NC 2

G G Allen NC 3

G G Allen NC 4

IGGAHen NC 5

I NC 1

Blv-wei9hted E1nnual emission rate a11eragea ever the units If they are operated In accordance with the

propo68d av-eraglng plan

C _o_.3_7_6 __ ___,

t i-'l IR.r., x Hl~j

Where,

0.68

0.68

0.40

0.40

0.40

0.40

0.40

0.40

0.40

0.250 26,834,070

0.250 27,664,080

0.250 13,315,200

0.450 18,755,160

0.450 21,094,080

0.450 29,048,160

0.450 36,362,760 -

0.450 35,013.720

0.450 41 662,560

Btu--welghted annual average emission rate for same units operated in compliance with 40 CFR 76.5, 76.6 or 76.7 L 0.443

t ~~1

Ru ~ Alternative contemporaneous ararual em!,;slon limitation far unit l, In lb/mmBtu, as specified in column {b) Of Step 1:

Ru "'

Hl1 :

n =

Applicable ~rnission llmlurtion for unit I, In lblmmBtu, as specified ln column (a) of Step 1;

l Annual heat input for unit i, in mmBtu, as specified lo colum!"i (c) of step 1; Number of uoh In the a11eraglng plan

----

·-

':' DA c-,-,.,,..... 7C.'1 n '"'Jn re,., ,:"'ro"- ., "ln1 A't

Page 89: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

bant Name (from Step 1} Roxboro

STEP3

NOxAvereging - Page 2

R<teelvod

Identify fhe first calendar I ~• in which this plan Jan a 1 2015 WIii apply. _ u ry ' '---------------------'

JUN 2 ii Wb

ftJJ Permits Secffor i

STEP4

Read the spacial provisions and certification, enter lhe name of the designatad representative, and sign and date.

Special Provisions

Emission Limitations

Each artectBd unit in an approved averaging plan is in compliance ""1th the Acid Rain emi&sion ~mitation for NOx under the plan o"IY If the following requirements are met

(II For each unit. the unit's actual annual average emission rate for the calendar year. in lb/mmBtu, Is less than or equal lo its alternative oontern,oonineous annual emJssion limitation in the averaging pPan, and (a) For each unit with an altematl111> C:Of'ltemporaneous emission !Imitation 185& stringent than the applicable emission limttation Jn 40 CFR 76.5, 76.8, or 76_7. the actual annual heat input for the calendat year does not exceed the annual heat inpl.lt Mmtt in the averaging plan, (b) For each unit wm, an altemative contemporaneous emission limllatfon mora stringent than lhe applicable emission limitation In 40 CFR 7 6.5, ?6.6, or 76. 7, the actual annual heat input for lhe calendar year is not IBl!e tflan the ann11al heat input limit In the S'1eraging plan, or (II) If one or more of the units does not meet the requirements of (i), the designaied representa1ive shaM demon91l'ale, in accordance with 40 CFR 76.11(d)(1)(ii){A) ar1d (B), that the actual Btu-weighted ann.ial average emission rate for lhe 1,mits in the plan fs less than or equal to the Btu-weighted enrrual ave raga rate for the same units had they each been operate((, during the same period of lime, In compliance wilh. !he applicable emission limiratlon$ in 40 CFR 76.5, 76.6, or 76.7. (iii) Ir there is a suc.ceaeful group showing of compliartee under 40 CFR 76.11{ d)( 1 .)(iiXA) and (B) for a calendar year, 1hen all unit& in lhe averaging plan shall be deemed to be in compliance for that year wHh 1heir alternative contemporaneous emission llmi1etions and annual heat input limits under (i).

The owners end operators of ei unit governed by an approved averaging plan shaD be liable for any 11iolation of the plan or this section at that unit or ai,y other 111it in the plan, including liabiUty for fulfilling the obligations specified in part 77 of this chapter and sections 113 and 411 of the Act.

TerminatiOn

The designated represenlatlve may submit a nolificalion to terminate ein appn:,ved averaging plan, in acc:;ordance with 40 CFR 72.40(d), no later than October 1 of the calendar year for which the plan is to be terminated.

Certification

I am authori2:ed to make this submission on behalf of the owners and operators of lhe affected source or affected units for which the submission is made. I certify Uf'der penalty of law lhat I have personally examined, and am familiar with, the statements and Information submit1ed in this document and an lll!l attachments. Ba5ed on my inquiry of those lndl11iduals witfl primary responsibility for obtaining the informalion, I certify that the 61atements and Information are lo the best of my knowledge and belief true, accurate, and complete. I am .;lware 1hat there~ significant penalties for submitting false statements and lnformliltion or omitting required statements and information, Including the possibility of fine or imprisonment.

E Larry . Hatcher

EPA Form 761CJ-29 (Revised 7-2014)

Page 90: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

~ /ant Name (from Step 1 J Roxboro

STEP 1 Contlm,e the ldentfflcation of units from step I page 1, here-.

P~tName

Marshall

, 1 Marshall

Marshall

Mayo

Mayo

Roxboro

Roxboro

Roxboro

Roxboro

Roxboro

Roxboro

-

I

I

I EPA Form 761 C-29 (R.ev!sed 7-2014)

..

---

!

State Unit ID#

NC 2

NC 3

NC 4

NC 1A

NC 18

NC 1

NC 2

NC CS003A

NC CS003B

NC CS004A

NC CSD048

I

- ,____ -

-- C-- -----

I

--

NDx:Averagfng - Page 3

(a) [bl

EmiS9lon Lirnilation

0.40

0.40

0.40

0.46

0.46

0.46

0.40

0.46

0.46

0.46

0.46

I J

M Contemp. Emission Llmitalion

0.450

0.250

0.450

0.250

0.250

0.250

0.250

0.250

0.250

0.250

0.250

I

(c)

AnOOcll Heat lnput Limit

39,787,920

16,438,140

65,577,360

10,731,000

10,731,000

10,341,180

15,794,280

9,331,590

9,331,590

9,855,000

9,855,000

-

·-

l

Page 91: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

Attachment 3 to Air Quality Permit 01001156 Duke Energy Progress, LLC - Roxboro Steam Electric Plant

Phase II Acid Rain Permit NOx Compliance Plan

(Dated June 23, 2015) (Two pages)

Page 92: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

&EPA United States Envlronmerrtal Prolactlon A(jem:y Acid Rain Program

0MB No, 20to-025t Approval expJres 11130/201~

Acid Rain NOx Compliance Plan For more lnformatfon, see inllfructlons and refer to 4D CFR 76.9 Page 1

Thissubmisston is: D New X Revised Page 1 of 2

STEP1 I I I llldlcat& plant name, State, and Plant c<ide from thecurNnt Plant Name Roxboro NC 2712 Certlflcal& of Representation coW11n9 thahcilily. ,__ _ _______ _ _ _____ ________ _ ..L_s_ta_te _ __,_Plan __ t_Co_ d_e __

STEP2

(&I 51111\dard annual ave rage 1m illlllon llmltatlon or 0.50 lblmm.blu (for eb1RJ di} bottom wall-&Ted boilers)

(bJ Standard annual ._.,e emission ITrnitafion of 0.45 lblmm81u ~• ft!!!lli lalls,enliallyfited boilers)

{c:) 5'8ndard aMual average emission llmltlflir,n of 0.48 lbllior11Blu (for fh!!!!1! d~ bGno111 wlll-flr.d lboU&r.1 •

.__

Id) SW!Clard annq aw,ase .,mi:s&lon llmlUCl1tn of DAO lblmm8t11 (tw ~ wtgentlally fired bollera)

l•) Standard annual IYerqe amiss Ion limitation of O,GB lbfmmlliu (for cell bwri~r bolll!fll

,(f) 5\.lndard .. nua1it11eraga llfflfllelon limllallun oi O, 16 lb/ll'lmB!u (1or cyc\ona bGll11111!

Ce) Standard annual awtD!I• 41mf811lon lln'll~tion ofO.BU IAJlfflmBt.v, (far -,erll~ally fi"'d bolleiS)

I (t,) stamlard 11nn11.i average emillsion lhni\ftlon al l>.114 lb/111111Blll llor Wet

j bonom IIDll,rs)

EPA FOIT11 761D-2a (Revised 7-2014)

Jdenllfy each affected Group 1 and Group 2 boiler using the unil IDs from tha cuminl Cerllffcat. c Repreeentalion coYerlng the facility. Also indicate the baifar type: Ree• tor cefl burner, "CY" for cyclonE "DBWn fOf' dry bottom wall-fired, "T" for tangentially fired, ·v· for vertically fired, and "WBN for we bcttorn, and select ttae compliance option for each unit by makln9 an 'X' In the appropriate row an, column.

ID# 1 to# 2 IO#CS003A ID#CS003B 10#CS004A -- ID# CS0O4B

Type DBW Type T Type DBW Type DBW Type DBW Type DBW

--

j j

I

Page 93: MICHAEL ABRACZINSKAS Ash/documents/Coal Ash/air-quality... · Mr. Jason Haynes November 27, 2018 Page 2 You may request modification of your Air Quality Pennit through informal means

"lOx Col]lpliance - Page 2 rtecewcd

JU~ 2 i: ZOl5

>.ir Pe.rmtts Sectfor STEP 2, Ci)nt'd

Plem Name (From Step 1) Roxboro

ID# 1 JD# 2 10# CS003A 10# CS003B l 10# CS004A ID# CS004B

Type DBW Type T Type DBW Type DBW Type DBW {i) NO,. A"'tro11ging Plan (Include wo~ Avera91n9 fonn) X X X X X

- -U) C111111mon st&1:k plffllwant to 40 CFR 75.17{e)(2)Cil[A) (ch1c:ktf'le 111MClard emlYlon lrmltatlon boll abDVe fot inolit sill ngard lil'llilatin n appliwdlle ID an~ unit uqtl&'lng staekj

._ lie) Conlm011 stack Pll~l/!.lnt ta 40 CFI!' 75.17(aKiJCl)(B) with HO~ Averaglag (1:ll111;k the HO,. Averaging Plan 1101< end I nc1110 a NOii A¥er.141iln9 f Of111) 1

Ill EPA;ipproved' C0111m0l'I stack •ppo,n ion m enl method pun:u 11nt tr> -4 0

I CFR 75.17fal(:Z.l(i)(C), (a)t2)(HtJ(f!), or (b)(2}

STEP 3: Identify the fir.st calendar year in whlc.h this plan will apply.

I Januaiy1,2016

STEP 4: Read the speclat provisions and certification, enter the name of lhe designated repreaentative, sign and date.

Special Provisions

-

Type

General. This so_urce is subject 10 the &tandard reQulremenls in 40 CFR 72.9. These. requirements are listed In this 80U1Ge's Add Rain Pemiit.

Certification

DBW

X

.

I am authorized t11 make this submission on behalf of Ile owners and operak:lrs ol lhe affaded source or affected units for which lhe submission Is made. J certify under penalfy of law that r have peraonal/y ellilminad, and am famJlli:lr with, the statements and ln!Qrmalion submitted in 1hls document and ~I its attachments. Based on my inqull)' of those indlviduals wtth primary responslbffify for oblairling ltle infom1euon, I certify tl'l.1t the statements and if\formelion are la the beSt Qf my knowledge and belief true, accurate, and cr.mplete. I am aw.ire 1h11t there are s!gnillcant penalties for subm~in9 fa.fse slallilmenl:s a~ Information or omitting requlr«I slalements and iroormatlon, including lhe possibility of fine or lmpm!OOmesit.

lame Larry ft.. Hatcher

~~naw~ 4c..-E:.'-'---. l~-=--'""""""";___ _____ _____ ~ b_a_re_ <>/;;;.3 /JS EPA Form 7610.28 (RCl/lsed 7-2014)