International Atomic Energy Agency Metrological Traceability in Special Fields A. Fajgelj, M. Groening, K. Burns, S. Bamford Agency’s Laboratories Seibersdorf and Vienna IAEA-IUPAC-IUPAP Workshop on ‘Emerging Issues on Metrology in Chemistry’ 17. February 2004, IAEA Vienna, Austria
24

Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

Apr 26, 2018

Download

Documents

dangthuan
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

Metrological Traceability in Special FieldsA. Fajgelj, M. Groening, K. Burns, S. Bamford

Agency’s Laboratories Seibersdorf and Vienna

IAEA-IUPAC-IUPAP Workshop on ‘Emerging Issues on Metrology in Chemistry’

17. February 2004, IAEA Vienna, Austria

Page 2: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

Example 1:Example 1:

Metrological Traceability of Values Assigned to Matrix Metrological Traceability of Values Assigned to Matrix Reference MaterialsReference Materials

Page 3: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

reference material certified referencematerial

standard referencematerial

standard secondary standard secondary referencematerial

control sample laboratory controlsample

calibration standard

calibration solution calibrator measurement standard(etalon)

international(measurement) standard

national (measurement)standard

primary standard

secondary standard reference standard working standard

transfer standard travelling standard multicomponentstandard

cocktail pure substance standard matrix referencematerial

Terminology related to Terminology related to CRMsCRMs

Page 4: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

• Matrix (compositional) reference material:A “natural” substance more representative of laboratory samples that has been chemically characterised for one or more elements, constituents, etc. with a known uncertainty. (Note: This is not a standardised definition.)

Sub-groups: gaseous, environmental, biological, alloys, etc.Characterisation & certification: mainly through intercomparisons

Terminology related to Terminology related to CRMsCRMs

Page 5: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

AQCS RMs Sales StatisticsAQCS RMs Sales Statistics• The RM concept is applicable to

many fields of science; the AQCS stock represents many matrices and analytes, principally natural matrix reference materials for radionuclides, trace elements, organic contaminants and stable isotopes.

• AQCS currently serves more than 4000 customers and ships about 1300 units of reference materials, worth approximately 120 000 US $ annually.

Distribution of Reference Materials sold in 2002 by Analyte Type

Trace Elements28%

Radionuclides61%

Methylmercury2%

Organic Contaminants

4%

Page 6: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

Interlaboratory ComparisonsInterlaboratory Comparisons

Overall mean of accepted lab. means 9.95 [Bq*kg ]-1

95% Confidence intervals 9.13 - 10.59 [Bq*kg ]-1

90*

-1Sr

act

ivity

[Bq

kg]

All laboratory means in ascending order within the method

S0 S1 S2 S3 S5S4 S6 S7 S8 SA

n=13 n=9 n=8 n=6 n=4 n=4n=3 n=3n=5 n=9

75 45 189

165 43

51 107

1161 58 53

156 200

132

151 19 129

128

18

78 3652 55 19

414

9

199B

199A

185

176

110

162

71

131

3814

6 711

363

155

179

148

35 134 8410

9

197 195 24 16

359

118

88 114 95

0.1

1

10

100

1000

Overall mean of accepted lab. means

95% confidence interval for overall mean

number of lab. means

• AQCS has organized interlaboratory comparisons for the benefit of Member States laboratories on a cost free basis for over 40 years.

• These exercises represent an indispensable and cost effective tool which enable MS laboratories to compare their performance with that of other participants and also identify and rectify problems and biases with their analytical procedures.

Page 7: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

Main metrological and quality requirementsMain metrological and quality requirementsfor a new generation of the IAEA for a new generation of the IAEA RMsRMs

• Metrological traceability of assigned property values, whenever possible to SI Units.

• Measurement uncertainty of the assigned property value expressed following the GUM principles

• Quality system according to the ISO Guide 34

Page 8: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

Uncertainty of the assigned property valuesUncertainty of the assigned property values

Characterisation (Uchar)

Lab 3

Lab 2

Lab 1

Transport (Usts)

Storage (Ults)Between bottle variation (Sbb)

UCRM

(Ref: According to Jean Pauwels 1999)

Page 9: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

RM’s RM’s quality requirementsquality requirements

• As a general principle, the IAEA supports the use of ISO (ISO REMCO) Guides 30 to 35 as a basic guidance for activities related to reference materials.

• The use of ISO Guide 34 as a quality system guidance for reference materials producers is preferred.

• Small number of laboratories participating in characterisation of RM• reliable results assured (previous experience, QC, PT, etc.)• metrological traceability demonstrated• measurement uncertainty quantified• accreditation according to ISO 17025:1999 preferable

Page 10: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

Upgrading of selected AQCS RMs to Upgrading of selected AQCS RMs to CRMsCRMsTraceable to SI UnitsTraceable to SI Units

Selection criteria for materials to be upgraded

• Relevance of the material for radiological measurements in environmental or nutritional investigations

• More than 100 units have been ordered over the past 5 years

• A stock of more than 500 units is still available

Page 11: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

Upgrading of selected AQCS RMs toUpgrading of selected AQCS RMs to CRMsCRMsTraceable to SI UnitsTraceable to SI Units

Materials selected:

• IAEA-152 K-40, Sr-90, Cs-134, Cs-137 in milk powder

• IAEA-312 Ra, Th, U in soil

• IAEA-314 Ra, Th, U in stream sediment

• SOIL-6 Sr-90, Cs-137, Ra-226 and Pu-239 in soil

• SL-2 K-40, Sr-90, Cs-137, Pb-210, Ra-226, Ra-228, Th-228, Th-234, U-238, Pu-239/240 in lake sediment

• IAEA-375 K-40, Sr-90, Ru-106, Sb-125, I-129, Cs-134, Cs-137,Th-232, U-238 in soil

Page 12: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

Metrological traceability of XRF resultsMetrological traceability of XRF results

Traceability criteria requirements- Linkage to stated referencesFe-55 standard (equipment calibration)Pure metal foils, analytical grade oxides(method

calibration)Matrix reference materials - CRM (method validation)

- Stated uncertaintiesUncertainty budget estimation (Eg. X-ray Spectrom.

2003;32: 317- 335)

Page 13: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency-Unbroken chain of comparisons (through a hierarchy of standards and procedures)

Standards Procedures SI Units

Method validationCRM (matrix RM)

Method quantitationWorking standards

System optimisation Instrument calibration stds

Page 14: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

The Role of Standards in Establishing the The Role of Standards in Establishing the Traceability of XRF resultsTraceability of XRF results

• Some tools for establishing traceability in XRF analysis are the use of:

Standard reference data in method development.Certified analytical grade chemical reagents and chemically pure substances for method calibration.Certified/standard reference materials for method validation.Well documented and established methods for assessment of the uncertainty of analytical results.

Page 15: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

The Provision of Standards for XRF The Provision of Standards for XRF AnalysisAnalysis

• The standard reference data are available through compilations of photon interaction cross-sections, atomic data tables and newly published literature data.

• The analytical grade reagents and chemically pure substances are obtained through tested reliable suppliers and are always accompanied by certificates

• The most frequently used certified reference materials with guaranteed traceability are obtained from NIST or similar specialized institution

• The uncertainty budged evaluation is performed in accordance with international norms and standards

Page 16: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

Example 3:Example 3:

Metrological Traceability of Stable Isotope Metrological Traceability of Stable Isotope MeasurementsMeasurements

• The mass spectrometric measurement of natural variations of stable isotope ratios of light elements is used to delineate information on origin, age, climate and physical processes on analyzed compounds.

• It spans disciplines from hydrology to food science, from medicine to geochemistry, from biology to climate studies.

Page 17: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

Stable Isotope MeasurementsStable Isotope Measurements• As an example, oxygen will be discussed in more detail:

Isotopic composition of Vienna Standard Mean Ocean Water VSMOW, used as primary reference material for stable isotope measurements on oxygen and hydrogen

0.0020004(5)0.0003790(9)0.9976206(5)Isotopic abundance

18O17O16O

Total variability of oxygen stable isotope ratios in natural materials on earth:

R18O/16O = 0.0020052 ± 10 %

Page 18: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

• In most real studies the variation of the isotopic ratio R is much lower (only about ± 1-2 ‰)

• Required high precision of ratio measurements of about ± 0.1 ‰ can be achieved only by relative measurements comparing directly sample and standard

Annual average uncertainty for δ18O analyses at IHL

00.010.020.030.040.050.060.070.080.09

1990 1992 1994 1996 1998 2000 2002 2004

Year

δ18O

unc

erta

inty

[‰]

Page 19: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

with the definition: δ18OVSMOW = 0 ‰

R18O/16OVSMOW = 0.0020052 ⇔ δ18OVSMOW = 0 ‰

R18O/16Osample = 0.0020072 ⇔ δ18Osample = 1 ‰

(R18O/16Osample- R18O/16OVSMOW)R18O/16OVSMOW

δ18O [‰] = ·1000

!!

For convenience a new scale is introduced (conventional δ-scale) to report only deviations between ratios R with VSMOW artificially defined as the zero point for all measurements and serving as primary reference material:

!

δδ--ScalesScales

Page 20: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

Absolute ratio determinations (isotope dilution)

Traceability SchemeTraceability Scheme

R18O/16OVSMOW

R2H/1HVSMOW

VSMOW (H2O) Primary reference

material

δ18OVSMOW= 0 ‰δ2HVSMOW= 0 ‰

Internal Laboratory standard (H2O)

Calibrated sample δ18Osample

Internal Laboratory standard (H2O) - R46/44

Transfer Standard (CO2) - R46/44

Sample (H2O) - R46/44

Calibration

Calibration Comparison

Page 21: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

-4

-2

0

2

4

6

8

-1.2 -1.0 -0.8 -0.6 -0.4 -0.2 0.0 0.2 0.4

δ18O vs. VSMOW [per mill]

δ2 H vs

. VSM

OW

[per

mill]

IAEA

Lab 2

Lab 3

Lab 4

Lab 5, 18O only

NEW VSMOW

Keeping Keeping δδ--scales consistentscales consistent• VSMOW: 70 litres produced in 1967; distributed in 20ml amounts in sealed glass ampoules (1 unit per 3yrs)

• Only 7 litres left at IAEA, 5 litres at NIST !

±0.08 (115)

±0.006 (109)

Uncertainty VSMOW (no. of analyses)

±0.09 (118)

±0.007 (125)

Uncertainty NewVSMOW(no. of analyses)

-0.120.002Deviation NewVSMOW vs. VSMOW

δ2H [‰]δ18O [‰]

• Replacement prepared by IAEA and calibrated by 5 laboratories: NewVSMOW –300 litres

⇒ Calibr. uncertainty about 10 times smaller than routine lab precision

Page 22: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

• second water standard used to normalize the VSMOW δ-scale :

• Standard Light Antarctic Precipitation SLAP δ18OSLAP= -55.5 ‰

Successor material also already in preparation with isotopic composition close to SLAP from mixing two raw waters from Southpole and from Vostok

⇒ Replacements for both primary reference materials prepared in quantities sufficient for estimated 30-50 years

NewSLAPNewSLAP--ProjectProject

Page 23: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

Necessary Change of StandardsNecessary Change of Standards

• SMOW ⇒ VSMOW: Vienna–SMOW ( H, O )• PDB ⇒ VPDB: Vienna–PDB ( C )• CDT ⇒ VCDT: Vienna–CDT ( S )

• PDB and CDT standards depletion (already decades ago) forced establishment of new artefacts to keep scales consistent (NBS19 and IAEA-S-1)

• SMOW never existed physically

Page 24: Metrological Traceability in Special Fieldsold.iupac.org/divisions/V/news/040217/IAEA.pdfradionuclides, trace elements, organic contaminants and stable isotopes. • AQCS currently

International Atomic Energy Agency

Carbon Stable Isotopes Carbon Stable Isotopes

• NBS19 carbonate as calibrator, defines VPDB-scale. Several other carbonates available, as well as CO2 RMs.

• Several organic carbon materials exist (oil, sucrose, polyethylene, cellulose), but reveal relatively large uncertainties

• Problem of consistent calibration of organic versus inorganic carbon reference materials

• Demand to create various new RMs with different compounds