PRIMERA ITERACION CIRCUITO I tramo D (pulg) L(Km) Qo hfo(m) 1--2 4 0.4 100 220 3459.698 2--4 4 0.2 120 60 111.589 3--4 4 0.4 120 -60 -223.178 1--3 4 0.2 100 -200 -1450.213 Σ 1897.897 CIRCUITO II tramo D (pulg) L(Km) Qo hfo(m) 2--5 6 0.4 100 100 111.684 6--5 6 0.2 100 -20 -2.844 6--4 4 0.4 120 20 29.240 2--4 4 0.2 120 -60 -111.589 Σ 26.492 CH CH
41

metodo hardy croos para redes de tuberias

Dec 08, 2015

Download

Documents

un metodo iterativo para el calculo de caudales en redes de tuberias
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: metodo hardy croos para redes de tuberias

PRIMERA ITERACION

CIRCUITO Itramo D (pulg) L(Km) Qo hfo(m) hfo/Qo

1--2 4 0.4 100 220 3459.698 15.726

2--4 4 0.2 120 60 111.589 1.860

3--4 4 0.4 120 -60 -223.178 3.720

1--3 4 0.2 100 -200 -1450.213 7.251

Σ 1897.897 28.556

CIRCUITO II

tramo D (pulg) L(Km) Qo hfo(m) hfo/Qo

2--5 6 0.4 100 100 111.684 1.117

6--5 6 0.2 100 -20 -2.844 0.142

6--4 4 0.4 120 20 29.240 1.462

2--4 4 0.2 120 -60 -111.589 1.860Σ 26.492 4.581

CIRCUITO III

tramo D (pulg) L(Km) Qo hfo(m) hfo/Qo

CH

CH

CH

Page 2: metodo hardy croos para redes de tuberias

6--4 4 0.4 120 -20 -29.240 1.462

9--6 4 0.2 100 -180 -1193.385 6.630

9--8 4 0.4 100 180 2386.769 13.260

8--4 4 0.2 100 20 20.485 1.024Σ 1184.629 22.376

CIRCUITO IV

tramo D (pulg) L(Km) Qo hfo(m) hfo/Qo

3--4 4 0.4 120 60 223.178 3.720

8--4 4 0.2 100 -20 -20.485 1.024

8--7 6 0.4 100 20 5.687 0.284

3--7 4 0.2 100 -60 -156.353 2.606Σ 52.027 7.634

NOTATramo Caudal COMO VEMOS LA CONDICION ΔQ<1%Q CUMPLE EN LA SEPTIMA ITERACIÓN1--2 177.560

2--4 48.396 CAUDAL3--4 -74.349

1--3 -242.440

2--5 69.164

6--5 -50.836

6--4 21.867

9--6 -212.703

9--8 147.297

8--4 15.388

8--7 -8.091

3--7 -88.091

CH

1 2

2 4

3 4

1 3

2 5

6 5

6 4

9 6

9 8

8 4

8 7

3 7

177.560

48.396

74.349

242.440

69.164

50.836

21.867

212.703

147.297

15.388

8.091

88.091

lQ slQ slQ slQ slQ slQ slQ slQ slQ slQ slQ slQ s

Page 3: metodo hardy croos para redes de tuberias

CONDICION ΔQ<1%QΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE tramo

-35.925 184.075 1.841 NO 1--2-32.799 27.201 0.272 NO 2--4-32.241 -92.241 -0.922 NO 3--4-35.925 -235.925 -2.359 NO 1--3

ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE tramo

-3.126 96.874 0.969 NO 2--5-3.126 -23.126 -0.231 NO 6--525.491 45.491 0.455 NO 6--432.799 -27.201 -0.272 NO 2--4

ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE tramo

Page 4: metodo hardy croos para redes de tuberias

-25.491 -45.491 -0.455 NO 6--4-28.617 -208.617 -2.086 NO 9--6-28.617 151.383 1.514 NO 9--8-24.933 -4.933 -0.049 NO 8--4

ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE tramo

32.241 92.241 0.922 NO 3--424.933 4.933 0.049 NO 8--4-3.684 16.316 0.163 NO 8--7-3.684 -63.684 -0.637 NO 3--7

COMO VEMOS LA CONDICION ΔQ<1%Q CUMPLE EN LA SEPTIMA ITERACIÓN

1 2

2 4

3 4

1 3

2 5

6 5

6 4

9 6

9 8

8 4

8 7

3 7

177.560

48.396

74.349

242.440

69.164

50.836

21.867

212.703

147.297

15.388

8.091

88.091

lQ slQ slQ slQ slQ slQ slQ slQ slQ slQ slQ slQ s

Page 5: metodo hardy croos para redes de tuberias

SEGUNDA ITERACION

CIRCUITO ID (pulg) L(Km) Qo hfo(m) hfo/Qo ΔQ

4 0.4 100 184.075 2487.691 13.515 -0.967

4 0.2 120 27.201 25.824 0.949 21.077

4 0.4 120 -92.241 -494.518 5.361 19.359

4 0.2 100 -235.925 -1968.603 8.344 -0.967

Σ 50.394 28.169

CIRCUITO II

D (pulg) L(Km) Qo hfo(m) hfo/Qo ΔQ

6 0.4 100 96.874 105.311 1.087 -22.044

6 0.2 100 -23.126 -3.720 0.161 -22.044

4 0.4 120 45.491 133.733 2.940 -21.329

4 0.2 120 -27.201 -25.824 0.949 -21.077Σ 209.500 5.137

CIRCUITO III

D (pulg) L(Km) Qo hfo(m) hfo/Qo ΔQ

CH

CH

CH

Page 6: metodo hardy croos para redes de tuberias

4 0.4 120 -45.491 -133.733 2.940 21.329

4 0.2 100 -208.617 -1567.922 7.516 -0.716

4 0.4 100 151.383 1732.596 11.445 -0.716

4 0.2 100 -4.933 -1.538 0.312 19.610Σ 29.404 22.212

CIRCUITO IV

D (pulg) L(Km) Qo hfo(m) hfo/Qo ΔQ

4 0.4 120 92.241 494.518 5.361 -19.359

4 0.2 100 4.933 1.538 0.312 -19.610

6 0.4 100 16.316 3.902 0.239 -20.326

4 0.2 100 -63.684 -174.574 2.741 -20.326Σ 325.384 8.653

CH

Page 7: metodo hardy croos para redes de tuberias

TERCERA ITERACION

CONDICION ΔQ<1%QQ1 =Qo + ΔQ 0.01Q CUMPLE tramo D (pulg)

183.108 1.831 SI 1--2 448.278 0.483 NO 2--4 4-72.883 -0.729 NO 3--4 4-236.892 -2.369 SI 1--3 4

Q1 =Qo + ΔQ 0.01Q CUMPLE tramo D (pulg)74.830 0.748 NO 2--5 6-45.170 -0.452 NO 6--5 624.163 0.242 NO 6--4 4-48.278 -0.483 NO 2--4 4

Q1 =Qo + ΔQ 0.01Q CUMPLE tramo D (pulg)

Page 8: metodo hardy croos para redes de tuberias

-24.163 -0.242 NO 6--4 4-209.333 -2.093 SI 9--6 4150.667 1.507 SI 9--8 414.677 0.147 NO 8--4 4

Q1 =Qo + ΔQ 0.01Q CUMPLE tramo D (pulg)72.883 0.729 NO 3--4 4-14.677 -0.147 NO 8--4 4-4.009 -0.040 NO 8--7 6-84.009 -0.840 NO 3--7 4

Page 9: metodo hardy croos para redes de tuberias

TERCERA ITERACION

CIRCUITO IL(Km) Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ

0.4 100 183.108 2463.568 13.454 -4.572 178.536

0.2 120 48.278 74.642 1.546 -2.209 46.069

0.4 120 -72.883 -319.834 4.388 -3.545 -76.428

0.2 100 -236.892 -1983.557 8.373 -4.572 -241.464Σ 234.819 27.762

CIRCUITO II

L(Km) Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ

0.4 100 74.830 65.317 0.873 -2.363 72.467

0.2 100 -45.170 -12.836 0.284 -2.363 -47.533

0.4 120 24.163 41.484 1.717 0.401 24.564

0.2 120 -48.278 -74.642 1.546 2.209 -46.069Σ 19.324 4.420

CIRCUITO III

L(Km) Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ

CH

CH

CH

Page 10: metodo hardy croos para redes de tuberias

0.4 120 -24.163 -41.484 1.717 -0.401 -24.564

0.2 100 -209.333 -1577.885 7.538 -2.765 -212.097

0.4 100 150.667 1717.476 11.399 -2.765 147.903

0.2 100 14.677 11.555 0.787 -1.738 12.939Σ 109.662 21.441

CIRCUITO IV

L(Km) Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ

0.4 120 72.883 319.834 4.388 3.545 76.428

0.2 100 -14.677 -11.555 0.787 1.738 -12.939

0.4 100 -4.009 -0.291 0.073 -1.027 -5.036

0.2 100 -84.009 -291.430 3.469 -1.027 -85.036Σ 16.558 8.717

CH

Page 11: metodo hardy croos para redes de tuberias

CUARTA ITERACION

CONDICION ΔQ<1%Q0.01Q CUMPLE tramo D (pulg) L(Km)1.785 NO 1--2 4 0.40.461 NO 2--4 4 0.2-0.764 NO 3--4 4 0.4-2.415 NO 1--3 4 0.2

0.01Q CUMPLE tramo D (pulg) L(Km)0.725 NO 2--5 6 0.4-0.475 NO 6--5 6 0.20.246 NO 6--4 4 0.4-0.461 NO 2--4 4 0.2

0.01Q CUMPLE tramo D (pulg) L(Km)

Page 12: metodo hardy croos para redes de tuberias

-0.246 NO 6--4 4 0.4-2.121 NO 9--6 4 0.21.479 NO 9--8 4 0.40.129 NO 8--4 4 0.2

0.01Q CUMPLE tramo D (pulg) L(Km)0.764 NO 3--4 4 0.4-0.129 NO 8--4 4 0.2-0.050 NO 8--7 6 0.4-0.850 NO 3--7 4 0.2

Page 13: metodo hardy croos para redes de tuberias

CIRCUITO I CONDICION ΔQ<1%QQo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q

100 178.536 2350.977 13.168 -0.297 178.239 1.782

120 46.069 68.447 1.486 2.393 48.463 0.485

120 -76.428 -349.210 4.569 2.236 -74.192 -0.742

100 -241.464 -2054.961 8.510 -0.297 -241.761 -2.418Σ 15.253 27.733

CIRCUITO II

Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q

100 72.467 61.553 0.849 -2.691 69.776 0.698

100 -47.533 -14.106 0.297 -2.691 -50.224 -0.502

120 24.564 42.769 1.741 -2.453 22.111 0.221

120 -46.069 -68.447 1.486 -2.393 -48.463 -0.485Σ 21.768 4.373

CIRCUITO III

Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q

CH

CH

CH

Page 14: metodo hardy croos para redes de tuberias

120 -24.564 -42.769 1.741 2.453 -22.111 -0.221

100 -212.097 -1616.654 7.622 -0.238 -212.335 -2.123

100 147.903 1659.629 11.221 -0.238 147.665 1.477

100 12.939 9.152 0.707 2.295 15.234 0.152Σ 9.359 21.292

CIRCUITO IV

Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q

120 76.428 349.210 4.569 -2.236 74.192 0.742

100 -12.939 -9.152 0.707 -2.295 -15.234 -0.152

100 -5.036 -0.443 0.088 -2.533 -7.569 -0.076

100 -85.036 -298.053 3.505 -2.533 -87.569 -0.876Σ 41.561 8.870

CH

Page 15: metodo hardy croos para redes de tuberias

QUINTA ITERACION

CONDICION ΔQ<1%Q CIRCUITO ICUMPLE tramo D (pulg) L(Km) Qo

SI 1--2 4 0.4 100 178.239NO 2--4 4 0.2 120 48.463NO 3--4 4 0.4 120 -74.192SI 1--3 4 0.2 100 -241.761

Σ

CIRCUITO II

CUMPLE tramo D (pulg) L(Km) QoNO 2--5 6 0.4 100 69.776NO 6--5 6 0.2 100 -50.224NO 6--4 4 0.4 120 22.111NO 2--4 4 0.2 120 -48.463

Σ

CIRCUITO III

CUMPLE tramo D (pulg) L(Km) Qo

CH

CH

CH

Page 16: metodo hardy croos para redes de tuberias

NO 6--4 4 0.4 120 -22.111SI 9--6 4 0.2 100 -212.335SI 9--8 4 0.4 100 147.665NO 8--4 4 0.2 100 15.234

Σ

CIRCUITO IV

CUMPLE tramo D (pulg) L(Km) QoNO 3--4 4 0.4 120 74.192NO 8--4 4 0.2 100 -15.234NO 8--7 6 0.4 100 -7.569NO 3--7 4 0.2 100 -87.569

Σ

CH

Page 17: metodo hardy croos para redes de tuberias

CONDICION ΔQ<1%Qhfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE2343.740 13.149 -0.561 177.678 1.777 SI75.170 1.551 -0.333 48.130 0.481 SI-330.548 4.455 -0.408 -74.600 -0.746 SI-2059.644 8.519 -0.561 -242.322 -2.423 SI28.718 27.675

hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE57.391 0.823 -0.228 69.548 0.695 SI-15.619 0.311 -0.228 -50.452 -0.505 SI35.204 1.592 0.074 22.185 0.222 SI-75.170 1.551 0.333 -48.130 -0.481 SI1.806 4.277

hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE

Page 18: metodo hardy croos para redes de tuberias

-35.204 1.592 -0.074 -22.185 -0.222 SI-1620.006 7.629 -0.302 -212.637 -2.126 SI1654.700 11.206 -0.302 147.363 1.474 SI12.380 0.813 -0.149 15.085 0.151 SI11.871 21.240

hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE330.548 4.455 0.408 74.600 0.746 SI-12.380 0.813 0.149 -15.085 -0.151 SI-0.942 0.125 -0.153 -7.722 -0.077 NO-314.685 3.594 -0.153 -87.722 -0.877 SI2.541 8.986

Page 19: metodo hardy croos para redes de tuberias

SEXTA ITERACION

CIRCUITO Itramo D (pulg) L(Km) Qo hfo(m) hfo/Qo

1--2 4 0.4 100 177.678 2330.114 13.114

2--4 4 0.2 120 48.130 74.219 1.542

3--4 4 0.4 120 -74.600 -333.920 4.476

1--3 4 0.2 100 -242.322 -2068.493 8.536

Σ 1.919 27.669

CIRCUITO II

tramo D (pulg) L(Km) Qo hfo(m) hfo/Qo

2--5 6 0.4 100 69.548 57.044 0.820

6--5 6 0.2 100 -50.452 -15.750 0.312

6--4 4 0.4 120 22.185 35.422 1.597

2--4 4 0.2 120 -48.130 -74.219 1.542Σ 2.497 4.271

CIRCUITO III

tramo D (pulg) L(Km) Qo hfo(m) hfo/Qo

CH

CH

CH

Page 20: metodo hardy croos para redes de tuberias

6--4 4 0.4 120 -22.185 -35.422 1.597

9--6 4 0.2 100 -212.637 -1624.272 7.639

9--8 4 0.4 100 147.363 1648.443 11.186

8--4 4 0.2 100 15.085 12.157 0.806Σ 0.906 21.228

CIRCUITO IV

tramo D (pulg) L(Km) Qo hfo(m) hfo/Qo

3--4 4 0.4 120 74.600 333.920 4.476

8--4 4 0.2 100 -15.085 -12.157 0.806

8--7 6 0.4 100 -7.722 -0.978 0.127

3--7 4 0.2 100 -87.722 -315.701 3.599Σ 5.083 9.008

CH

Page 21: metodo hardy croos para redes de tuberias

CONDICION ΔQ<1%QΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE tramo

-0.037 177.640 1.776 SI 1--20.279 48.409 0.484 SI 2--40.268 -74.333 -0.743 SI 3--4-0.037 -242.360 -2.424 SI 1--3

ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE tramo

-0.316 69.232 0.692 SI 2--5-0.316 -50.768 -0.508 SI 6--5-0.293 21.892 0.219 NO 6--4-0.279 -48.409 -0.484 SI 2--4

ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE tramo

Page 22: metodo hardy croos para redes de tuberias

0.293 -21.892 -0.219 NO 6--4-0.023 -212.660 -2.127 SI 9--6-0.023 147.340 1.473 SI 9--80.282 15.367 0.154 NO 8--4

ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE tramo

-0.268 74.333 0.743 SI 3--4-0.282 -15.367 -0.154 NO 8--4-0.305 -8.027 -0.080 NO 8--7-0.305 -88.027 -0.880 SI 3--7

Page 23: metodo hardy croos para redes de tuberias

SEPTIMA ITERACION

CIRCUITO ID (pulg) L(Km) Qo hfo(m) hfo/Qo ΔQ

4 0.4 100 177.640 2329.204 13.112 -0.067

4 0.2 120 48.409 75.015 1.550 -0.044

4 0.4 120 -74.333 -331.707 4.462 -0.047

4 0.2 100 -242.360 -2069.085 8.537 -0.067

Σ 3.426 27.661

CIRCUITO II

D (pulg) L(Km) Qo hfo(m) hfo/Qo ΔQ

6 0.4 100 69.232 56.566 0.817 -0.023

6 0.2 100 -50.768 -15.934 0.314 -0.023

4 0.4 120 21.892 34.561 1.579 0.013

4 0.2 120 -48.409 -75.015 1.550 0.044Σ 0.178 4.259

CIRCUITO III

D (pulg) L(Km) Qo hfo(m) hfo/Qo ΔQ

CH

CH

CH

Page 24: metodo hardy croos para redes de tuberias

4 0.4 120 -21.892 -34.561 1.579 -0.013

4 0.2 100 -212.660 -1624.598 7.639 -0.035

4 0.4 100 147.340 1647.966 11.185 -0.035

4 0.2 100 15.367 12.581 0.819 -0.015Σ 1.387 21.222

CIRCUITO IV

D (pulg) L(Km) Qo hfo(m) hfo/Qo ΔQ

4 0.4 120 74.333 331.707 4.462 0.047

4 0.2 100 -15.367 -12.581 0.819 0.015

6 0.4 100 -8.027 -1.051 0.131 -0.020

4 0.2 100 -88.027 -317.735 3.610 -0.020Σ 0.341 9.022

CH

Page 25: metodo hardy croos para redes de tuberias

OCTAVA ITERACION

CONDICION ΔQ<1%QQ1 =Qo + ΔQ 0.01Q CUMPLE tramo D (pulg)

177.573 1.776 SI 1--2 448.364 0.484 SI 2--4 4-74.379 -0.744 SI 3--4 4-242.427 -2.424 SI 1--3 4

Q1 =Qo + ΔQ 0.01Q CUMPLE tramo D (pulg)69.209 0.692 SI 2--5 6-50.791 -0.508 SI 6--5 621.904 0.219 SI 6--4 4-48.364 -0.484 SI 2--4 4

Q1 =Qo + ΔQ 0.01Q CUMPLE tramo D (pulg)

Page 26: metodo hardy croos para redes de tuberias

-21.904 -0.219 SI 6--4 4-212.696 -2.127 SI 9--6 4147.304 1.473 SI 9--8 415.352 0.154 SI 8--4 4

Q1 =Qo + ΔQ 0.01Q CUMPLE tramo D (pulg)74.379 0.744 SI 3--4 4-15.352 -0.154 SI 8--4 4-8.047 -0.080 SI 8--7 6-88.047 -0.880 SI 3--7 4

Page 27: metodo hardy croos para redes de tuberias

OCTAVA ITERACION

CIRCUITO IL(Km) Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ

0.4 100 177.573 2327.580 13.108 -0.005 177.569

0.2 120 48.364 74.888 1.548 0.033 48.397

0.4 120 -74.379 -332.092 4.465 0.032 -74.348

0.2 100 -242.427 -2070.143 8.539 -0.005 -242.431Σ 0.234 27.660

CIRCUITO II

L(Km) Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ

0.4 100 69.209 56.532 0.817 -0.037 69.171

0.2 100 -50.791 -15.947 0.314 -0.037 -50.829

0.4 120 21.904 34.598 1.580 -0.035 21.869

0.2 120 -48.364 -74.888 1.548 -0.033 -48.397Σ 0.295 4.259

CIRCUITO III

L(Km) Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ

CH

CH

CH

Page 28: metodo hardy croos para redes de tuberias

0.4 120 -21.904 -34.598 1.580 0.035 -21.869

0.2 100 -212.696 -1625.097 7.640 -0.002 -212.698

0.4 100 147.304 1647.235 11.183 -0.002 147.302

0.2 100 15.352 12.558 0.818 0.034 15.386Σ 0.097 21.221

CIRCUITO IV

L(Km) Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ

0.4 120 74.379 332.092 4.465 -0.032 74.348

0.2 100 -15.352 -12.558 0.818 -0.034 -15.386

0.4 100 -8.047 -1.055 0.131 -0.036 -8.084

0.2 100 -88.047 -317.872 3.610 -0.036 -88.084Σ 0.606 9.024

CH

Page 29: metodo hardy croos para redes de tuberias

NOVENA ITERACION

CONDICION ΔQ<1%Q0.01Q CUMPLE tramo D (pulg) L(Km)1.776 SI 1--2 4 0.4 1000.484 SI 2--4 4 0.2 120-0.743 SI 3--4 4 0.4 120-2.424 SI 1--3 4 0.2 100

0.01Q CUMPLE tramo D (pulg) L(Km)0.692 SI 2--5 6 0.4 100-0.508 SI 6--5 6 0.2 1000.219 SI 6--4 4 0.4 120-0.484 SI 2--4 4 0.2 120

0.01Q CUMPLE tramo D (pulg) L(Km)

CH

CH

CH

Page 30: metodo hardy croos para redes de tuberias

-0.219 SI 6--4 4 0.4 120-2.127 SI 9--6 4 0.2 1001.473 SI 9--8 4 0.4 1000.154 SI 8--4 4 0.2 100

0.01Q CUMPLE tramo D (pulg) L(Km)0.743 SI 3--4 4 0.4 120-0.154 SI 8--4 4 0.2 100-0.081 SI 8--7 6 0.4 100-0.881 SI 3--7 4 0.2 100

CH

Page 31: metodo hardy croos para redes de tuberias

CIRCUITO I CONDICION ΔQ<1%QQo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q

177.569 2327.469 13.107 -0.008 177.561 1.77648.397 74.982 1.549 -0.005 48.392 0.484-74.348 -331.829 4.463 -0.005 -74.353 -0.744-242.431 -2070.215 8.539 -0.008 -242.439 -2.424

Σ 0.407 27.659

CIRCUITO II

Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q69.171 56.475 0.816 -0.003 69.169 0.692-50.829 -15.968 0.314 -0.003 -50.831 -0.50821.869 34.496 1.577 0.002 21.871 0.219-48.397 -74.982 1.549 0.005 -48.392 -0.484

Σ 0.020 4.257

CIRCUITO III

Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q

Page 32: metodo hardy croos para redes de tuberias

-21.869 -34.496 1.577 -0.002 -21.871 -0.219-212.698 -1625.132 7.641 -0.004 -212.702 -2.127147.302 1647.184 11.182 -0.004 147.298 1.47315.386 12.609 0.820 -0.002 15.384 0.154Σ 0.164 21.220

CIRCUITO IV

Qo hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q74.348 331.829 4.463 0.005 74.353 0.744-15.386 -12.609 0.820 0.002 -15.384 -0.154-8.084 -1.064 0.132 -0.002 -8.086 -0.081-88.084 -318.114 3.612 -0.002 -88.086 -0.881

Σ 0.041 9.026

Page 33: metodo hardy croos para redes de tuberias

DECIMA ITERACION

CONDICION ΔQ<1%Q CIRCUITO ICUMPLE tramo D (pulg) L(Km) Qo

SI 1--2 4 0.4 100 177.561SI 2--4 4 0.2 120 48.392SI 3--4 4 0.4 120 -74.353SI 1--3 4 0.2 100 -242.439

Σ

CIRCUITO II

CUMPLE tramo D (pulg) L(Km) QoSI 2--5 6 0.4 100 69.169SI 6--5 6 0.2 100 -50.831SI 6--4 4 0.4 120 21.871SI 2--4 4 0.2 120 -48.392

Σ

CIRCUITO III

CUMPLE tramo D (pulg) L(Km) Qo

CH

CH

CH

Page 34: metodo hardy croos para redes de tuberias

SI 6--4 4 0.4 120 -21.871SI 9--6 4 0.2 100 -212.702SI 9--8 4 0.4 100 147.298SI 8--4 4 0.2 100 15.384

Σ

CIRCUITO IV

CUMPLE tramo D (pulg) L(Km) QoSI 3--4 4 0.4 120 74.353SI 8--4 4 0.2 100 -15.384SI 8--7 6 0.4 100 -8.086SI 3--7 4 0.2 100 -88.086

Σ

CH

Page 35: metodo hardy croos para redes de tuberias

CONDICION ΔQ<1%Qhfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE2327.276 13.107 -0.001 177.560 1.776 SI74.967 1.549 0.004 48.396 0.484 SI-331.875 4.463 0.004 -74.349 -0.743 SI-2070.341 8.540 -0.001 -242.440 -2.424 SI

0.028 27.659

hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE56.471 0.816 -0.004 69.164 0.692 SI-15.970 0.314 -0.004 -50.836 -0.508 SI34.501 1.577 -0.004 21.867 0.219 SI-74.967 1.549 -0.004 -48.396 -0.484 SI0.035 4.257

hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE

Page 36: metodo hardy croos para redes de tuberias

-34.501 1.577 0.004 -21.867 -0.219 SI-1625.192 7.641 0.000 -212.703 -2.127 SI1647.097 11.182 0.000 147.297 1.473 SI12.607 0.819 0.004 15.388 0.154 SI0.011 21.220

hfo(m) hfo/Qo ΔQ Q1 =Qo + ΔQ 0.01Q CUMPLE331.875 4.463 -0.004 74.349 0.743 SI-12.607 0.819 -0.004 -15.388 -0.154 SI-1.065 0.132 -0.004 -8.091 -0.081 SI-318.131 3.612 -0.004 -88.091 -0.881 SI0.072 9.026

Page 37: metodo hardy croos para redes de tuberias

Tramo Caudal1 1--2 177.5602 2--4 48.3963 3--4 -74.3494 1--3 -242.4405 2--5 69.1646 6--5 -50.8367 6--4 21.8678 9--6 -212.7039 9--8 147.297

10 8--4 15.38811 8--7 -8.09112 3--7 -88.091