Metalux SPECIFICATION FEATURES Construction Rigid housing is die formed of code gauge prime cold rolled steel and features full length die-formed stiffeners and unibody endplate for added strength. Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Unibody endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. Ample KOs are provided for continuous row wiring. Endplates have integral Grid-lock feature for safety and convenience. Controls The RLN LED is Powered by Fifth Light, with a standard 0-10V continuous dimming driver that works with any 0-10V control/ dimmer. Combine with energy saving products like occupancy sensors, daylighting controls and lighting relay panels to maximize energy savings. In addition, the RLN can include a factory-installed integrated sensor system for occupancy and daylight dimming control and manual control from an optional handheld remote. Or, specify the Digital Addressable Lighting Interface (DALI) drivers, dimmable down to 10%, for use with Fifth Light controls. See ordering information for details on all three options. Electrical Long-Life LED system coupled with electrical driver to deliver optimal performance. LED’s available in 3000K, 3500K or 4000K with a minimum CRI of 80. Projected life is 60,000 hours at 94% lumen output. cULus listed. Electronic drivers are available for 120-277V applications. Emergency Battery Pack Option Optional 120V-277V integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 90-minute batteries provide constant power to the LED system, ensuring code- compliance. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. See ordering information for details. Finish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Housing and ballast cover finished with new 90% reflective white enamel for superior performance. Hinging/Latching Positive cam action steel latches with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. Door assembly hinges down for easy access from below without tools. Frame/Sheilding Die formed, heavy gauge, flat steel door with reinforced mitered corners and painted after fabrication, baked matte white enamel finish. Positive light seals. Acrylic frosted lens. Compliance Modules are UL recognized components and indoor luminaires are cULus listed for 25ºC ambient environments, RoHS compliant, and LED modules comply with IESNA LM-79 and LM-80 standards. DesignLights Consortium ® Qualified and classified for DLC Standard, refer to www. designlights.org for details. Warranty Five year warranty. RLN blends modern styling with an innovative optical design. This contemporary, high quality luminaire provides superior visual comfort and is dedicated to the latest solid-state lighting and driver technology for optimal performance and energy efficiency. The RLN is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The RLN series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. DESCRIPTION CERTIFICATION DATA cULus 1598 Damp Location Listed IC Rated LM79/LM80 Compliant ROHS Compliant DesignLights Consortium® Qualified Catalog # Type Date Project Comments Prepared by PS519128EN 10-10-2017 22RLN LED 2' X 2' TROFFER LED MODULE Specification Grade Troffer Rectilinear Shielding 23-3/4" [603mm] 3-1/4" [83mm] RECTILINEAR Safe and convenient means of disconnecting power RLN Fl at, White Steel DOOR FRAMES 23-3/4" [603mm] 23-3/4" [603mm] MOUNTING DATA
5
Embed
Metalux 22RLN 2' x 2' LED Specification Grade Troffer with ... · PDF fileMetalux SPECIFICATION FEATURES Construction Rigid housing is die formed of code gauge prime cold rolled steel
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Metalux
SPECIFICATION FEATURES
ConstructionRigid housing is die formed of code gauge prime cold rolled steel and features full length die-formed stiffeners and unibody endplate for added strength. Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Unibody endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. Ample KOs are provided for continuous row wiring. Endplates have integral Grid-lock feature for safety and convenience.
ControlsThe RLN LED is Powered by Fifth Light, with a standard 0-10V continuous dimming driver that works with any 0-10V control/ dimmer. Combine with energy saving products like occupancy sensors, daylighting controls and lighting relay panels to maximize energy savings. In addition, the RLN can include a factory-installed integrated sensor system for occupancy and daylight dimming control and manual control from an optional handheld remote. Or, specify the Digital Addressable Lighting Interface (DALI) drivers, dimmable down to 10%, for use with Fifth Light controls. See ordering information for details on all three options.
ElectricalLong-Life LED system coupled with electrical driver to deliver optimal performance. LED’s available in 3000K, 3500K or 4000K with a minimum CRI of 80. Projected life is 60,000 hours at 94% lumen output. cULus listed. Electronic drivers are available for 120-277V applications.
Emergency Battery Pack OptionOptional 120V-277V integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 90-minute batteries provide constant power to the LED system, ensuring code-compliance. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. See ordering information for details.
FinishMultistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Housing and ballast cover finished with new 90% reflective white enamel for superiorperformance.
Hinging/LatchingPositive cam action steel latches with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. Door assembly hinges down for easy access from below without tools.
Frame/SheildingDie formed, heavy gauge, flat steel door with reinforced mitered corners and painted after fabrication, baked matte white enamel finish. Positive light seals. Acrylic frosted lens.
ComplianceModules are UL recognized components and indoor luminaires are cULus listed for 25ºC ambient environments, RoHS compliant, and LED modules comply with IESNA LM-79 and LM-80 standards. DesignLights Consortium® Qualified and classified for DLC Standard, refer to www.designlights.org for details.
WarrantyFive year warranty.
RLN blends modern styling with an innovative optical design. This contemporary, high quality luminaire provides superior visual comfort and is dedicated to the latest solid-state lighting and driver technology for optimal performance and energy efficiency. The RLN is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility.
The RLN series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas.
DESCRIPTION
C E R T I F I C A T I O N D A T A
cULus 1598
Damp Location Listed
IC Rated
LM79/LM80 Compliant
ROHS Compliant
DesignLights Consortium® Qualified
Catalog # Type
Date
Project
Comments
Prepared by
PS519128EN10-10-2017
22RLNLED
2 ' X 2 ' T R O F F E R L E D M O D U L E
Spec i f i ca t ion Grade Trof ferRect i l inear Shie ld ing
23-3/4" [603mm]
3-1/4"[83mm]
RECTILINEAR
Safe and convenient means of disconnecting power
R L NF la t , W h it e St e e l
DOOR FRAMES
23-3/4"[603mm]
23-3/4" [603mm]
MOUNTING DATA
Specifications and dimensions subject to change without notice.
Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting
22RLN LED RECTILINEAR SHIELDING
Ceiling TrimType TypeExposed Grid GConcealed T GSlot Grid G
(Verify compatibility/ consultfactory.)
GGrid/Lay-inStandard
GConcealed T
GSlot Grid
CEILING COMPATIBILITY
ENERGY AND PERFORMANCE DATA BY CATALOG NUMBER
Ambient Temperature
TM-21 LumenMaintenance
(60,000 hours)
TheoreticalL70
(Hours)
25°C > 94% > 368,000
LUMEN MAINTENANCE
PS519128EN10-10-2017
Stock orMTO*
Catalog Logic (Rectilinear Shielding)
DeliveredLumens
WattsEfficacy(lm/W)
MTO 22RLN-LD5-20-UNV-L830-CD1-U 1935 16.43 118
MTO 22RLN-LD5-20-UNV-L835-CD1-U 2016 16.43 123
MTO 22RLN-LD5-20-UNV-L840-CD1-U 2016 16.43 123
MTO 22RLN-LD5-25-UNV-L830-CD1-U 2441 20.9 117
STOCK 22RLN-LD5-25-UNV-L835-CD1-U 2543 20.9 122
STOCK 22RLN-LD5-25-UNV-L840-CD1-U 2543 20.9 122
MTO 22RLN-LD5-31-UNV-L830-CD1-U 3029 26.6 114
MTO 22RLN-LD5-31-UNV-L835-CD1-U 3155 26.6 119
MTO 22RLN-LD5-31-UNV-L840-CD1-U 3155 26.6 119
MTO 22RLN-LD5-35-UNV-L830-CD1-U 3416 30.57 112
STOCK 22RLN-LD5-35-UNV-L835-CD1-U 3558 30.57 116
STOCK 22RLN-LD5-35-UNV-L840-CD1-U 3558 30.57 116
MTO 22RLN-LD5-40-UNV-L830-CD1-U 3882 35.6 109
MTO 22RLN-LD5-40-UNV-L835-CD1-U 4044 35.6 114
MTO 22RLN-LD5-40-UNV-L840-CD1-U 4044 35.6 114
MTO 22RLN-LD5-44-UNV-L830-CD1-U 4238 39.62 107
MTO 22RLN-LD5-44-UNV-L835-CD1-U 4415 39.62 111
MTO 22RLN-LD5-44-UNV-L840-CD1-U 4415 39.62 111
*Made to order (MTO) requires a typical four week lead time.
Lumen Adjustment Factors 80->90 CRI
Example of LumenAdjustment Calculation
3000K
3500K
4000K
0.865
0.861
0.883
22RLN-LD5-25-UNV-L935-CD1-Uat 90CRI at 3500K
Lumen Adjustment Factor = 0.861
Total Light Output =2,543 lm x 0.861 = 2,190 lm
Efficacy = = 104.8 lm/W2,190 lm20.9 W
5000K n.a.
90 CRI
Specifications and dimensions subject to change without notice.
Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting
PHOTOMETRICS
22RLN LED RECTILINEAR SHIELDING
PS519128EN10-10-2017
22RLN-LD5-25-UNV-L835-CD1-U
Electronic Driver
Linear LED 3500K
Spacing criterion: (II) 1.19 x mounting height, (⊥) 1.23 x mounting height
5LTD=Fifth Light DALI Driver(10% - 100% Dimming) (4), (6)
SR=Sensor Ready (1% to 100% dimming)
(11)
PackagingU=Unit PackPALC=JobPack, in carton
Stock Lumen Output25=2500 Lumen35=3500 Lumen
MTO Lumen Output20=2000 Lumen31=3100 Lumen40=4000 Lumen44=4400 Lumen
NOTES: (1)An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (2)Products also available in non-US voltages and frequencies for international markets. (3)With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. (4)Must be used in conjunction with a DALI control system. For complete DALI solutions by Fifth Light visit www.eaton.com/lightingsystems. (5)Flex does not include dimming leads. Control leads provided by others. (6)2000, 2500,3100 and 3500 Lumen packages not available with Step- Dim (SD) and Fifth Light (5LTD) driver option. (7) DesignLights Consortium® Qualified and classified for DLC Standard/Premium (all lumen packages), refer to www.designlights.org for details. (8) 347V versions are not available with emergency options. (9) Used to transfer fixture to secondary power source for life-safety operation. When used with a dimming fixture, two devices are required to ensure control is disabled while operating under emergency power. (10) Integral sensors work with CD and HCD drivers only and is factory prewired to the driver for stand-alone control. (11) SR driver compatible with LWI option only. (12) LWT compatible with CD and HCD drivers only. (13) LWT sensor is external to luminaire, cable factory wired. Must be used in conjunction with a LumaWatt Pro control system. For complete LumaWatt Pro wireless solutions, visit www.eaton.com/lumawattpro Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information.
Integrated SolutionsS=Integrated Sensor (10)
L=LumaWatt
Control TypeV=Analog (0-10V) Output for Local Control (10)
Specifications and dimensions subject to change without notice.
Eaton 1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.eaton.com/lighting
INTEGRATED SENSOR
22RLN LED RECTILINEAR SHIELDING
PS519128EN10-10-2017
The RLN with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The RLN delivers superior lighting with integrated occupancy and daylighting controls.
Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the RLN delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is unoccupied.
The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method.
Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02) provides code compliant manual raise, lower, ON, OFF control.
The RLN with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings.
How it works:
• As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level.
• Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 20 minutes).
• If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable light level is typically half of the occupied daylight level.
• At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting.