Chapter 4 Boiler and steam generators Dr. Taib Iskandar Mohamad MET 401 Power Plant Engineering
40

MET 401 Chapter 4 boilers_and_steam_generators

Jan 19, 2015

Download

Documents

 
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: MET 401 Chapter 4 boilers_and_steam_generators

Chapter 4Boiler and steam generators

Dr. Taib Iskandar Mohamad

MET 401 Power Plant Engineering

Page 2: MET 401 Chapter 4 boilers_and_steam_generators

2

Steam generator

To generate steam at desired rate, pressure and temperature

Fuel and air burn in furnace Heat water Steam

Used in fossil fuel and nuclear fuel power plants.

Classification:1. Utility steam generator2. Industrial steam generator3. Marine steam generator

Page 3: MET 401 Chapter 4 boilers_and_steam_generators

3

Steam generator components

• Economizer• Boiler• Superheater• Reheater• Air heater• Auxiliaries (ash handling, control, fan, burner

etc)

Page 4: MET 401 Chapter 4 boilers_and_steam_generators

4

Page 5: MET 401 Chapter 4 boilers_and_steam_generators

5

Page 6: MET 401 Chapter 4 boilers_and_steam_generators

6

Boiler

• A boiler is an enclosed vessel where combustion heat is transferred into water until it becomes heated water or steam.

• The hot water or steam under pressure is then usable for transferring the heat to a process.

• When water is boiled into steam, its volume increases about 1,600 times, producing a force that is almost as explosive as gunpowder.

Page 7: MET 401 Chapter 4 boilers_and_steam_generators

The boiler system comprises of: feed water system, steam system and fuel system.

The feed water system provides water to the boiler and regulates it automatically to meet the steam demand.

Various valves provide access for maintenance and repair. The steam system collects and controls the steam produced in the boiler. Steam is directed through a piping system to the point of use. Throughout the system, steam pressure is regulated using valves and

checked with steam pressure gauges. The fuel system includes all equipment used to provide fuel to generate

the necessary heat. The equipment required in the fuel system depends on the type of fuel used in the system.

A typical boiler room schematic is shown in Figure 2.1.

2.2 Boiler Systems

Page 8: MET 401 Chapter 4 boilers_and_steam_generators

2.2 Boiler Systems

Figure 2.1: Boiler Room Schematic.

Page 9: MET 401 Chapter 4 boilers_and_steam_generators

The water supplied to the boiler that is converted into steam is called feed water.

The two sources of feed water are: ◦ (1) Condensate or condensed steam returned from the

processes and◦ (2) Makeup water (treated raw water) which must come from

outside the boiler room and plant processes. For higher boiler efficiencies, the feed water is

preheated by economizer, using the waste heat in the flue gas.

2.2 Boiler Systems

Page 10: MET 401 Chapter 4 boilers_and_steam_generators

There are virtually infinite numbers of boiler designs but generally they fit into one of two categories:◦ 1) Fire Tube Boiler, and◦ 2) Water Tube Boiler.

2.3 Boiler Types

Page 11: MET 401 Chapter 4 boilers_and_steam_generators

Fire tube or “fire in tube” boilers; contain long steel tubes through which the hot gasses from a furnace pass and around where the water to be converted to steam circulates. (Refer to Figure 2.2). Fire tube boilers, typically have a lower initial cost, are more fuel efficient and easier to operate, but they are limited generally to capacities of 25 tons/hr and pressures of 17.5 kg/cm2.

2.3 Boiler Types: Fire Tube

Page 12: MET 401 Chapter 4 boilers_and_steam_generators

2.3 Boiler Types: Fire Tube

Figure 2.2: Fire Tube Boiler.

Page 13: MET 401 Chapter 4 boilers_and_steam_generators

Water tube or “water in tube” boilers in which the conditions are reversed with the water passing through the tubes and the hot gasses passing outside the tubes (see figure 2.3). These boilers can be of single- or multiple-drum type. These boilers can be built to any steam capacities and pressures, and have higher efficiencies than fire tube boilers.

2.3 Boiler Types: Water Tube

Page 14: MET 401 Chapter 4 boilers_and_steam_generators

2.3 Boiler Types: Water Tube

Figure 2.3: Water Tube Boiler.

Page 15: MET 401 Chapter 4 boilers_and_steam_generators

The packaged boiler is called so because it comes as a complete package. Once delivered to site, it requires only the steam, water pipe work, fuel supply and electrical connections to be made for it to become operational. Package boilers are generally of shell type with fire-tube design so as to achieve high heat transfer rates by both radiation and convection (Refer to Figure 2.4).

2.3 Boiler Types: Packaged Boiler

Page 16: MET 401 Chapter 4 boilers_and_steam_generators

2.3 Boiler Types: Packaged Boiler

Figure 2.4: Packaged Boiler Cut-Away View.

Page 17: MET 401 Chapter 4 boilers_and_steam_generators

Fire Tube Boiler Advantages:◦Relatively inexpensive.◦ Easy to clean.◦Compact in size.◦Available in sizes from 176 kW/hr to 14,650 kW/hr.◦ Easy to replace tubes.◦Well suited for space heating and industrial process

applications.

2.4 Advantages and Disadvantages

Page 18: MET 401 Chapter 4 boilers_and_steam_generators

Fire Tube Boiler Disadvantages:◦Not suitable for high pressure applications 1.72 MPa and

above.◦ Limitation for high capacity steam generation.

2.4 Advantages and Disadvantages

Page 19: MET 401 Chapter 4 boilers_and_steam_generators

Water Tube Boiler Advantages:◦Available in sizes that are far greater than the firetube design.

Up to several million pounds per hour of steam. ◦Able to handle higher pressures up to 35 MPa.◦Recover faster than their firetube cousin.◦Have the ability to reach very high temperatures.

2.4 Advantages and Disadvantages

Page 20: MET 401 Chapter 4 boilers_and_steam_generators

Water Tube Boiler Disadvantages:◦High initial capital cost.◦Cleaning is more difficult due to the design.◦No commonality between tubes.◦ Physical size may be an issue.

2.4 Advantages and Disadvantages

Page 21: MET 401 Chapter 4 boilers_and_steam_generators

Economizer is a mechanical device intended to reduce energy consumption, or to perform another useful function such as preheating a fluid.

The feed water from the high pressure heaters enters the economizer and picks up heat from the flue gases after the low temperature superheater. Many types of economizer are designed for picking up heat from the flue gas. These can be classified as an inline or staggered arrangement based on the type of tube arrangement. The staggered arrangement is compact and occupies less volume for the same amount of heat transfer when compared to the inline arrangement.

Economizer

Page 22: MET 401 Chapter 4 boilers_and_steam_generators

Economizers are also designed with 1- plain tube and 2- fined tubes. The fins can be longitudinal or spiral. All these types are suitable for clean fuels like gas, oil, and low ash coals. For high ash coals, only the plain tube inline arrangement is used. This is mainly to reduce ash erosion and thus reduce erosion failures. These economizers pick up about 50 to 55 degrees centigrade in a large capacity boiler, which will reduce the flue gas temperature by about 150 to 170 degree centigrade. The boiler designers always keep the economizer water outlet temperature to about 25 to 35 degrees below the drum saturation temperature. This is done to mainly avoid steaming in the economizer. A steaming economizer generally is less reliable. As a rule of thumb, for every one degree pick up of economizer water temperature, there will be a drop of about 3 to 3.5 degrees

Page 23: MET 401 Chapter 4 boilers_and_steam_generators

Type:-

Page 24: MET 401 Chapter 4 boilers_and_steam_generators
Page 25: MET 401 Chapter 4 boilers_and_steam_generators

Economizer Advantages :-

1- A lowering of the flue gas temperature by 100 C 2- will improve the efficient rate by 5% 3- No falling below the dew point. 4- It does not cause condensation. 5- No special requirement on the material for flue gas ducts and

chimney. 6- Sufficient thermal buoyancy for the flue gases

Page 26: MET 401 Chapter 4 boilers_and_steam_generators

SuperheaterA superheater is a device used to convert saturated

steam or wet steam into dry steam used for power generation or processes.

Page 27: MET 401 Chapter 4 boilers_and_steam_generators

Cont. Definition

A superheater is a device in a steam engine, when considering locomotives, that heats the steam generated by the boiler again, increasing its thermal energy .

Page 28: MET 401 Chapter 4 boilers_and_steam_generators

Types of Superheaters

1- radiant superheater : is placed directly in the combustion chamber.

2- convection superheater: is located in the path of the hot gases.

3- separately fired superheater : as its name implies, is totally separated from the boiler.

Page 29: MET 401 Chapter 4 boilers_and_steam_generators

OPERATION

If superheated steam is required, the saturated steam must pass through a superheater. This is simply a heat exchanger where additional heat is added to the saturated steam.

Page 30: MET 401 Chapter 4 boilers_and_steam_generators

Advantages

1- reduced fuel and water consumption .

2- increased efficiency.

Page 31: MET 401 Chapter 4 boilers_and_steam_generators

Disadvantages

1- increased maintenance costs.

2- high pressure steam could escape through the operating if there is something wrong in the tube.

Page 32: MET 401 Chapter 4 boilers_and_steam_generators

An air reheater (APH) is a general term to describe any device designed to heat air before another process (for example, combustion in a boiler) with the primary objective of increasing the thermal efficiency of the process. They may be used alone or to replace a recuperative heat system or to replace a steam coil.

Air Reheater:

Page 33: MET 401 Chapter 4 boilers_and_steam_generators

Tubular type Operation: Tubular reheaters consist of straight tube bundles

which pass through the outlet ducting of the boiler and open at each end outside of the ducting. Inside the ducting, the hot furnace gases pass around the reheater tubes, transferring heat from the exhaust gas to the air inside the reheater.

Types:

Page 34: MET 401 Chapter 4 boilers_and_steam_generators

Problems:

The tubular reheater ductings for cold and hot air require more space and structural supports than a rotating reheater design

Page 35: MET 401 Chapter 4 boilers_and_steam_generators

:Rotating-plate regenerative air preheater

Operation:

In this design the whole air preheater casing is supported on the boiler supporting structure itself with necessary expansion joints in the ducting.

The vertical rotor is supported on thrust bearings at the lower end and has an oil bath lubrication, cooled by water circulating in coils inside the oil bath. This arrangement is for cooling the lower end of the shaft, as this end of the vertical rotor is on the hot end of the ducting. The top end of the rotor has a simple roller bearing to hold the shaft in a vertical position.

Page 36: MET 401 Chapter 4 boilers_and_steam_generators

The boiler flue gas contains many dust particles (due to high ash content) not contributing towards combustion, such as silica, which cause abrasive wear of the baskets, and may also contain corrosive gases depending on the composition of the fuel.

:Problems

Page 37: MET 401 Chapter 4 boilers_and_steam_generators

Definition of Reheater : is device use to gain heat.

ReheaterPower plant furnaces may have a reheater section containing tubes heated by hot flue gases outside the tubes. Exhaust steam from the high pressure turbine is passed through these heated tubes to collect more energy before driving the intermediate and then low pressure turbines.

Page 38: MET 401 Chapter 4 boilers_and_steam_generators

Reheater Steam from the exhaust of the first stage turbine goes back to the boiler for reheating and is returned to the second stage. Reheater coils in the flue gas path does the reheating of the returned steam. The reheat steam is at a much lower pressure than the super heated steam but the final reheater temperature is the same as the superheated steam temperature. Reheating to high temperatures improves the output and efficiency of the Power Plant. Final Reheater temperatures are normally in the range of 560 to 600 °C. Reheat steam pressures are normally around 45 bar

Page 39: MET 401 Chapter 4 boilers_and_steam_generators

Reheat Cycle

Page 40: MET 401 Chapter 4 boilers_and_steam_generators

Analysis of Reheat Cycle

1—2: Isentropic Pumping

2 –3 Constant (High)pressure Heat addition

3 –4 Isentropic expansion in HP turbine.

4—5 Constant (Low) Pressure Reheating.

5 – 6 Isentropic expansion in LP turbine.

6 – 1 Constant pressure condensation.

12 hhwp

43, hhw outhp

23, hhq SGin

45, hhq RHin

65, hhw outlp

16 hhqout