This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Sunnyvale, CA
Men’s Restrooms - Prototype
A: Entry Elevation
31
B: Entry Elevation - Translucent Panel C: West Elevation
3. COUNTER TOP: IceStone in White Pearl Color (ALT Option: CesarStone in 2200 Desert Limestone) 4. ACCENT FLOOR TILE: Crossville, Color Blox Too in A1126 Grey Matter, 12” x 18” 5. TYPICAL FLOOR TILE Crossville, Color Blox Too in A1176 Tabby Cat color, 12” x 18” 6. TYPICAL PAINT (WALL AND CEILING): Kelly Moore (Enviro-Cote) Skijour OW233-1 7. ACCENT PAINT: Kelly Moore (Enviro-Cote) Highland Grass KM3974-3 8. TRNASLUCENT PANEL: Knoll Imago in Mirage Pewter - IMmira 03
9. TRESHOLD: Absolute Black Granite
General Note: Refer to elevations for additional wall �nish designation
5
4
7
8
1 2
9
3
4 5
6
7
8
Earth Finish Palette
Sunnyvale, CA
Women’s Restroom - Prototype
ENLARGED WOMEN RESTROOM FINISH PLAN
5
47
8
1 2
9
3
4 5
6
7
8
5
EXAMPLE OF APPLICATION OF FINISHES SHOWN: EARTH FINISH PALETTE
1. TYPICAL WALL TILE : Crossville, Retro Active in A215 Empress White Unpolished, 3” x 12“
3. COUNTER TOP: IceStone in White Pearl Color (ALT Option: CesarStone in 2200 Desert Limestone) 4. ACCENT FLOOR TILE: Crossville, Color Blox Too in A1126 Grey Matter, 12” x 18” 5. TYPICAL FLOOR TILE Crossville, Color Blox Too in A1176 Tabby Cat color, 12” x 18” 6. TYPICAL PAINT (WALL AND CEILING): Kelly Moore (Enviro-Cote) Skijour OW233-1 7. ACCENT PAINT: Kelly Moore (Enviro-Cote) Highland Grass KM3974-3 8. TRNASLUCENT PANEL: Knoll Imago in Mirage Pewter - IMmira 03
9. TRESHOLD: Absolute Black Granite
General Note: Refer to elevations for additional wall �nish designation
Earth Finish Palette
Sunnyvale, CA
Men’s Restrooms - Prototype
MEN’S RESTROOM PLAN
1. COUNTER
2. MIRROR
3. SINK/FAUCET/SOAP DISPENSER/VANITY MIRROR
4. PAPER TOWEL DISPENSER/TRASH RECEPTACLE
5. HAND DRYER
6. PLUMBING FIXTURE
7. TOILET PARTITION
8. LEDGE/SHELF OVER URINAL (8” DEEP)
9. DOOR SIGNAGE
10. SCREEN
11. SEAT COVER DISPENSER AT EACH STALL
12. TOILET PAPER DISPENSER AND SHELF AT EACH STALL
13. GRAB BAR
1
7
6
9
10
3
11812
1
2 4
4 5
13
Sunnyvale, CA
Women’s Restroom - Prototype
Des
ign
Dev
elop
men
t: P
ropo
sed
Plan
(Wom
en)
WOMEN’S RESTROOM PLAN
1
2
3
4
6
7
89
1
3
45
10
11
12
1. COUNTER
2. MIRROR
3. SINK/FAUCET/SOAP DISPENSER/VANITY MIRROR
4. PAPER TOWEL DISPENSER/TRASH RECEPTACLE
5. HAND DRYER
6. PLUMBING FIXTURE
7. TOILET PARTITION
8. DOOR SIGNAGE
9. SCREEN
10. SEAT COVER DISPENSER AT EACH STALL
11. TOILET PAPER DISPENSER AND SHELF AT EACH STALL
12. GRAB BAR
Sunnyvale, CA
Restroom - Prototype
Des
ign
Dev
elop
men
t: P
ropo
sed
RC P
lan
(Men
)
MEN’S RESTROOM REFLECTED CEILING PLAN
1. LINEAR WALL MOUNTED LIGHT FIXTURE 2. VANITY LIGHT FIXTURE
1
2
1
2 2
Sunnyvale, CA
Restroom - Prototype
WOMEN’S RESTROOM REFLECTED CEILING PLAN
4
1
1
2
21
1. LINEAR WALL MOUNTED LIGHT FIXTURE
2. VANITY LIGHT FIXTURE
LOCKHEED MARTIN SPACE SYSTEM COMPANY Gensler
Interior Finish Standard
RES
TRO
OM
S: L
IGH
TIN
G F
IXTU
RES
TYPE A: TYPE B:
TYPE C1: TYPE C2: TYPE C3:
TYPE A: DOWNLIGHT (TYPICAL)
TYPE B: PERIMETER TROUGHT (OVER WC. AND URINAL)
TYPE C: VANITY FIXTURE (SELECT ONE) TYPE C1: RECESSED BETWEEN MIRROR TYPE C2: SURFACE ABOVE MIRROR TYPE C3: SURFACE BETWEEN MIRROR
274 80 36 / BACKSPACE 36
available colour: ALU ANODISED : 274 80 36 ANOINCL.1 x BACKSPACE 36 PC SBL 2G11 − 230−240V / 50Hz − 1 x 1~KVG 1 x TC−L − 36 W (max)
1.8 kg IP20norm: CEglowtest: 850°C
For detailed installation instructions, please consult the manual.
Direct / indirect surface mount(vertical surface mount available)Wall mount available
LAMPS
1 T5 or T5HO Lamp
MOUNTING
PRODUCT ORDERING CODES
7
Direct pendant (aircraft cable or stem)
SSBPDNO
NO
optics type
semi-spec bafflesblankperf
diffusingno optics
W
CWNO
clear acrylic lenswhite frosted lens
no lens
lens
4
4-8-12S # system
length / ft
AWC
aluminumwhite
custom
A
finish
54W28W
T5
T5HOT5
lamp
cover one side*cover two sides*
*for optics B P D C onlycover bottom face
no face to cover**see light distribution guide
NO
A AA
BNO
faces to cover**
120
120277347
voltage
sample
ordering o
ptions
1 one lamp
1
# lamps
MB
product id
pendantsurface
vertical surfacewall
MB+S+VS+W
R
end cap
minimal (tombstone)rectangle
TR
electronicrapid start
dimming(specify details)
E
EERSD
ballast
one circuittwo circuitsem. circuit
1
12+E
circuits
C customdescription
custom
B#
F
batt. pack(quan. / lumens)
fuse (one per ballast)
other
CA #CT#
SA18
CA36
suspension
cable (36" std)cable / t-bar
stem(length / inch)
S
VS
W
R
1/8" of endcap is sticking out of lens on both sides(all models: T and R)LENGTH
w/ ENDCAPS (T and R)
T5 / T5HO VERSION
4' (47 27/32")8' (96 17/32")12' (145 1/4")
T
INSTALLATION PAGES
2.33i
PRODUCT ORDERING CODE
Ballast Options Electronic, Dimmable, EmergencyEmergency Emergency Battery Pack or CircuitLamp Options T5, T5-HOVoltage 120, 277, 347Certification UL listed to U.S. & Canadian standards
End Cap Die Cast Zinc (0.065'' nominal)Housing Extruded Aluminum (0.062'' nominal)Lens Extruded Impact Modified Acrylic (0.100'' nominal)Interior Brackets Die Formed Sheet Steel (20 gauge)Hanger Die Cast Zinc (0.120'' nominal)Finish Anodized, Powder Coated, Lacquered
CONSTRUCTION ELECTRICAL
LAMP CONFIGURATIONS
OPTICSSee light distribution guide For Uplight / Downlight components (%)
Product design and development is an on going process atAxis Lighting. We reserve the right to change specifications.
Contact Axis for latest product information.
SURFACE MOUNT VERTICAL SURFACES & CEILINGS
Drywall ceiling(DM mounting)
Vertical Surface(DM mounting)
T-bar ceiling(TM mounting)
3 7/8"
2 3/8"
Stud
drywall
T-bar
ceiling tile
Stud
drywall
Both miniBox sizes can be fitted with a large number of optics, making it easy to control the distibution of light. By inserting infill panels or semi-spec baffles in the miniBox’s lens channels, you can greatly modify the fixture’s function and appearance. These optics can be specified when ordering (see product ordering code) or after the installation. This page will help you specify the right optics.
Face A refers to either side of the fixture’s lens. In the ordering codeyou will be asked to specify the number of A panels you will need. (Basically A transforms miniBox into an asymmetric fixture while AAmakes it a mostly direct fixture, depending on the nature of the infill.)
Face B refers to the bottom side of the lens. Please note that SS baffles come with their own A side blank infills unless specified otherwise. No need to specify A sides when ordering baffles.
SPECIFYING FACES TO COVER
OPTICS (examples with order codes)
A
B
4 foot miniBox, R endcap, with perf on one side22% Uplight / 78% Downlight
A
P
optics type
C 4 T5A
faces to cover
1MB R
4 foot miniBox, R endcap, with baffles32% Uplight / 68% Downlight
SS
optics type
C 4 T5B
faces to cover
1MB R
B
A A
4 foot miniBox, T endcap, with blank infills on two sides1% Uplight / 99% Downlight
B
optics type
C 4 T5AA
faces to cover
1MB T
B
A
4 foot miniBox, T endcap, with blank infills on one A side and bottom51% Uplight / 49% Downlight
Product design and development is an on going process atAxis Lighting. We reserve the right to change specifications.
Contact Axis for latest product information.
LIGHT DISTRIBUTION GUIDEFOR BAFFLES AND INFILL PANELS
Kurt Versen Company Point Source LightingWestwood, New Jersey 07675
H22VentingSlots
Branch CircuitJunction Box
ApertureFrame
RetainingSpring (2)
Full Lens Trim(Optional)
SquareTrim
AccessCover (2)
LockingSocket
Lamp(By Others)
FocalAdjustment
ElectronicBallast
PrimaryReflector
ADepth
H8632 6 " sq.153mm
12 "305mm
14 "356mm
26-32W Triple Tubecompact fluorescent
LampsNumber BAperture
CWidth
DLength
111/4"286mm
H8642 6 " sq.153mm
12 "305mm
14 "356mm
42W Triple Tubecompact fluorescent
111/4"286mm
Dimensions and Lamps
B
A
C
D
Number Lamps 85° 75° 65° 55° 45°
H863232W PL-T Philips 55 132 224 391 10904
32W T/E Osram/Syl 32 84 148 247 9212
H864242W PL-T Philips 54 147 252 436 15069
42W T/E Osram/Syl 37 116 231 2369 15908
Data in footlamberts. Photometer readings, Maximum Brightness Method.
Brightness
H8632 One 26 or 32W Triple Tube
H8642 One 42W Triple Tube
Compact Fluorescent Downlights6" Square Parabolic Trim
Optics and ApplicationsThe primary reflector has a unique faceted shape designed fortriple tube lamps. Distribution is for general use or task lighting.Suitable for damp locations.
Design FeaturesSteel housings protect and align reflectors and lamps. A safetylocking socket prevents lamp fallout. Trims are stabilized toprevent racking and are retained by constant pressure springs.Maximum ceiling thickness 11/2". Top or bottom service.
FinishStructural parts are painted matte black to suppress straylight leaks. Standard trims are anodized Softglow® clear.Special finishes, textures and colors are available.
Trim TexturesSelect among different embossed patterns to match theambiance of the space being illuminated. Refer to Squaresbrochure for descriptive photos.
BallastsFully electronic, microprocessor controlled with programmedstart to assure rated lamp life. Input voltage ranges from120V through 277V. Power factor .98, starting temperature0°F (-18°C), THD<10%. Pre-heat start < 1.0 second. Endof lamp life protection. Rated for > 50,000 starts.
GeneralFixtures are pre-wired, UL and C-UL listed for eight wire75°C branch circuit wiring. Union made IBEW. LuminaireEfficiency Rating (LER) data is in the photometric directorylocated in Section Z.
AccessoriesR2 26" support rails. WT White trim flange.R5 52" support rails. WHT White complete trim.SB Softglow black. BP Ball Peen texture.SG Softglow gold. CG Corrugated texture.SH Softglow mocha. DS Distressed texture.SP Softglow graphite. WV Woven texture.ST Softglow titanium. LL Linear spread lens.SW Softglow wheat. LP Large prism lens.SY Softglow pewter. MP Microprism lens.SZ Softglow bronze. DM Dimming ballast.BR Bright trim finish. V347 347 volt ballast.FC Four cell cross baffle. FR Frosting on lens,F Fuse. specify lens type.EM Emergency power includes integral charger light
and test switch visible through aperture. Battery operation for 90 minutes.
FLT6 Full lens trim, specify lens type, e.g. H8632-FLT6LL.WRL Wattage restriction label, specify wattage.
H8632 Osram 32W Triple Tube x .93H8642 Philips and Osram 42W Triple Tube x .86
P 42W
770814849850813724588436310176381713000000
3200*O 42W
898908903853797682550408297195861712000000
3200*°
°
° Vertical* Initial Lamp Lumens
P 32W
620643678692673615517389283174411511000000
2400*O 32W
6296506636486025294343392521668125141000000
2400*
Ceiling to FloorSingle Unit, Initial Footcandles, 30" Work Plane Multiple Units, Initial Footcandles, 30" Work Plane
Ceiling 80% Walls 50% Floor 20%
FC FC Diam Spacing RCR 1 RCR 3 RCR 8
Nadir
FC Diam FC Diam
Spacing is Maximum Over Work Plane
Notes1 For microprism spread lens multiply data x.88.
2 All data with standard trim, Softglow® clear.
3 Datachart degree headings measure one side from nadir. Diameter data includes both sides. Therefore the 20° column value describes a 40° pattern diameter at the work plane 30" above the floor. Footcandle values are at the diameter edge.
4 Datachart spacing is rounded off to the nearest foot.
5 Data by IES methods. Compact fluorescent data vary due to lamp lumen differences, power input, burning position, ambient temperature and ballast characteristics. A modification factor should be applied.
6 Colored trim multipliers: Gold x .90, Wheat x .85, Mocha x .80, Pewter x .80, Graphite x .75, Titanium x .75, Bronze x .70, Black x .70.
H8642 One 42W Osram Read Bottom Data
10° 20° 30°
30
21
16
12
10
29
20
15
12
16
2'
2'
3'
3'
3'
22
16
12
9
7
4'
5'
5'
6'
7'
12
8
6
5
4
6'
8'
9'
10'
11'
8'
9'
10'
11'
12'
8'
9'
10'
11'
12'
6'
7'
8'
9'
10'
38
27
21
16
13
32
23
17
13
11
23
16
12
10
8
H8642 One 42W Philips Read Top Data
25
18
14
11
9
27
19
14
11
9
2'
2'
3'
3'
3'
22
16
12
9
7
4'
5'
5'
6'
7'
13
9
7
5
4
6'
8'
9'
10'
11'
6'
7'
9'
10'
11'
30
22
16
13
10
26
19
14
11
9
18
13
10
7
6
Ceiling to FloorSingle Unit, Initial Footcandles, 30" Work Plane Multiple Units, Initial Footcandles, 30" Work Plane
Features A non-staggered 1- or 2-lamp T8 perimeter lightingsystem with a 9" aperture and optional parabolic or blade louvers.Blade louvers and lenses can be mounted either flush with ceilingplane (-l) or recessed 3 1/2" in housing (-h) for a floating ceilingappearance. A telescoping extension module offers dimensional flex-ibility while helping to illuminate corners and row-ends. The aluminum,semi-specular parabolic louver is 1 1/2" and 2 3/8" on center and provides34° longitudinal shielding.
Construction The housing, available in 2-, 3-, 4-, 6- or 8-foot stan-dard lengths, and wall rails are made of 20-gauge steel. Louver materi-al is semi-specular, low iridescent aluminum.
Finish The standard housing and trim color is gloss white (YGW)using polyester powder paint.
Electrical T8 fixtures have instant-start electronic ballasts with lessthan 20% THD. Fixtures are U.L. Damp labeled (non-emergency)and I.B.E.W. manufactured. Maximum ballast size available: 2 3/8"width x 1 1/2" height.
Mounting Fixture is recess-mounted in either exposed T-bar or hardceiling application(s).
0305 Prudential Lighting 1737 E. 22nd St. Los Angeles, CA 90058 phone 213.746.0360 fax 213.741.8590 www.prulite.com
Corner DetailRow Details
Mounting Locations
24", 36", 48"
24", 36", 48"
1-Lamp Row
2-Lamp Row
Telescoping Fixture
Telescoping Fixture
FillerKit
37"max
37"max
TelescopingLamp
FillerKit
TelescopingLamp
Corner Filler Kit(Trim to fit)
(1" min – 15", 25" or 37" max)
Standardx3B fixture
Standard x1 fixtureMounting bracket
Telescopingx1 fixture
Mounting rail
48" 48" 36"
48" 48" 36"
Standard Fixture Standard Fixture Standard Fixture
Standard Fixture Standard Fixture Standard Fixture
5"
4 1/4"
5"
24", 36", 48", 72" or 96"
7/8" dia K.O.
installation
In an effort to continually provide the highest quality products, Prudential reserves the right to change design specifications and/or materials, without notice.