For ordering information call: 1.866.906.8080/1.781.906.8080 or visit www.beaver-visitec.com Visitec® Cannula Meeting Diverse Needs with Consistent Quality The elements of cataract surgery are constantly evolving. Beaver-Visitec International helps you keep pace, with a wide range of cannula and cystotomes designed to meet the diverse needs and preferences of cataract surgeons. Visitec® cannula are available for a variety of procedures, including cataract, refractive, vitreoretinal, glaucoma, and oculoplastic procedures.
4

Meeting Diverse Needs with Consistent Quality · 2013-01-28 · in preventing Toxic Anterior Segment Syndrome (TASS). TASS is defined as an acute postoperative inflammatory reaction

Jul 03, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Meeting Diverse Needs with Consistent Quality · 2013-01-28 · in preventing Toxic Anterior Segment Syndrome (TASS). TASS is defined as an acute postoperative inflammatory reaction

For ordering information call: 1.866.906.8080/1.781.906.8080 or visit www.beaver-visitec.com

Visitec® CannulaMeeting Diverse Needs with Consistent Quality

The elements of cataract surgery are constantly evolving. Beaver-Visitec International helps you keep pace, with a wide range of cannula and cystotomes designed to meet the diverse needs and preferences of cataract surgeons.

Visitec® cannula are available for a variety of procedures, including cataract, refractive, vitreoretinal, glaucoma, and oculoplastic procedures.

Page 2: Meeting Diverse Needs with Consistent Quality · 2013-01-28 · in preventing Toxic Anterior Segment Syndrome (TASS). TASS is defined as an acute postoperative inflammatory reaction

Beaver-Visitec International

Visitec® Cannula Meeting Diverse Needs with Consistent Quality

The use of single-use cannula and instruments can play an important role in preventing Toxic Anterior Segment Syndrome (TASS). TASS is defined as an acute postoperative inflammatory reaction in which a noninfectious substance enters the anterior segment and induces toxic damage to the intraocular tissue.1

• Utilizing single-use cannula and instruments during cataract surgery may help prevent the occurrence of TASS.2

• A potential risk factor for TASS is resterilization of instruments between procedures.2

Anesthesia Administration

Description Item #

Retrobulbar (Sharp Point) .50 x 38 mm (25G x 1 ½ in) 581275

Retrobulbar [Atkinson] .50 x 38 mm (25G x 1 ½ in) 581637

Retrobulbar [Atkinson], .60 x 38 mm (23G x 1 ½ in) 581638

Retrobulbar (Curved), [Atkinson/Straus], .50 x 34 mm (25G x 1 3/8 in). Straight portion 11 mm, curved portion 24 mm. Dimensions after bending.

585019

Retrobulbar/Peribulbar [Atkinson] .60 x 32 mm (23G x 1 ¼ in) 585001

Retrobulbar/Peribulbar [Atkinson] .50 x 32 mm (25G x 1 ¼ in) 585108

Retrobulbar/Peribulbar [Atkinson] .40 x 32 mm (27G x 1 ¼ in) 585109

Peribulbar [Atkinson] .50 x 22 mm (25G x 7/8 in) 585027

Peribulbar [Atkinson] .60 x 22 mm (23G x 7/8 in)

585144

Peribulbar [Atkinson] .40 x 22 mm (27G x 7/8 in)

585145

Sub-Tenon’s Anesthesia Cannula 1.10 x 25 mm (19G x 1 in). Curved to radius of 30 mm and flattened to .65 mm. Designed for administering anesthetic agents into the posterior Sub-Tenon’s space.

585176

1. http://emedicine.medscape.com/article/1190343-overview

2. TASS Guidelines http://www.ascrs.org/TASS/index.cfm

Page 3: Meeting Diverse Needs with Consistent Quality · 2013-01-28 · in preventing Toxic Anterior Segment Syndrome (TASS). TASS is defined as an acute postoperative inflammatory reaction

www.beaver-visitec.com

For a more complete offering of products, please refer to our product catalog. Please visit www.beaver-visitec.com

Cystotomes

Description Item # Description Item #

Irrigating Cystotome.60 x 16 mm (23G x 5/8 in) 581594

Irrigating Cystotome.40 x 16 mm (27G x 5/8 in).Formed 8.5 mm from bend to tip.

585008

Irrigating Cystotome.60 x 16 mm (23G x 5/8 in) 581599

Irrigating Cystotome (Reverse).50 x 16 mm (25G x 5/8 in).Tip 90 degrees toward bevel.

585034

Side Cutting Irrigating Cystotome.50 x 16 mm (25G x 5/8 in) 581602

Irrigating Cystotome [Blumenthal].40 x 16 mm (27G x 5/8 in).Formed 8.5 mm from bend to tip.

585042

Irrigating Cystotome [Pearce].50 x 16 mm (25G x 5/8 in) 581610 Irrigating Cystotome [Blumenthal]

.40 x 16 mm (27G x 5/8 in). 585043

Irrigating Cystotome.50 x 16 mm (25G x 5/8 in) 581617

Irrigating Cystotome.50 x 16 mm (25G x 5/8 in).Tip 45 degrees.

585049

Irrigating Cystotome.40 x 16 mm (27G x 5/8 in) 581618

Irrigating Cystotome [Simcoe].40 x 12.5 mm (27G x 1/2 in).45 degrees, 10.5 mm from tip.

585093

Irrigating Cystotome.30 x 16 mm (30G x 5/8 in) 581630

Irrigating Cystotome [Blumenthal].50 x 16 mm (25G x 5/8 in).Formed 8.5 mm from bend to tip.

585113

Irrigating Cystotome.50 x 16 mm (25G x 5/8 in)Formed 8.5 mm from bend to tip.

585004

Cannula come packaged in a box of 10.

Page 4: Meeting Diverse Needs with Consistent Quality · 2013-01-28 · in preventing Toxic Anterior Segment Syndrome (TASS). TASS is defined as an acute postoperative inflammatory reaction

BVI, BVI Logo and all other trademarks (unless noted otherwise) are property of a Beaver-Visitec International (“BVI”) company © 2011 BVI

Beaver-Visitec International, Inc.411 Waverley Oaks Road, Waltham, MA 02452 Tel: 1.866.906.8080 Fax: 1.866.906.4304 www.beaver-visitec.com

590014-1210

Visitec® Cannula Helping Protect Patient Safety

Hydrodissection and Hydrodelineation

Description Item #

Nucleus Hydrodissector.30 x 22 mm (30G x 7/8 in).45 degrees, 7 mm from end. Also useful for irrigating incisions during refractive procedures.

581592

Micro J Shape Cannula.50 x 22 mm (25G x 7/8 in), .25 mm open end port. Hook 1.5 mm x 1.75 mm.

585003

Micro J Shape Hydrodissector [Pearce].40 x 22 mm (27G x 7/8 in).Hook 2.25 mm x 1.75 mm.

585029

Nucleus Hydrodissector [Pearce].50 x 22 mm (25G x 7/8 in).35 degrees, 8 mm from end.

585037

J Shape Cannula.60 x 22 mm (23G x 7/8 in)..33 mm open end port. Hook 2 mm x 2.25 mm.

585091

Nucleus Hydrodissector [Sauter].40 x 22 mm (27G x 7/8 in).Tip is flattened on the vertical plane.

585099

J Shape Hydrodissector [Pearce].50 x 22 mm (25G x 7/8 in).Hook 3 mm x 2 mm.

585102

Nucleus Hydrodissector.40 x 22 mm (27G x 7/8 in). Tip is flattened on the horizontal plane.

585155

Nucleus Hydrodissector [Chang].40 x 18 mm (27G x 7/10 in). 90 degree bend, 1 mm flattened tip, bevel angle 33 degrees.

585294

Nucleus Hydrodissector [Chang].40 x 18 mm (27G x 7/10 in). 90 degree bend, 1 mm flattened tip, bevel angle 47 degrees.

585295

Irrigation and Air Injection

Description Item #

Anterior Chamber Cannula [Rycroft].30 x 22 mm (30G x 7/8 in).45 degrees, 4 mm from end.

581273

Anterior Chamber Cannula [Rycroft].40 x 22 mm (27G x 7/8 in).45 degrees, 4 mm from end.

581280

Anterior Chamber Cannula [Rycroft].80 x 22 mm (21G x 7/8 in).45 degrees, 4 mm from end.

581281

Anterior Chamber Cannula.40 x 22 mm (27G x 7/8 in). Straight. 585006

Viscoflow Cannula.40 x 22 mm (27G x 7/8 in).Formed 11 mm from end; radius is 19 mm.

585007

Viscoflow Cannula.40 x 22 mm (27G x 7/8 in).45 degrees, 9 mm from end.

585026

Bishop Harmon Cannula1.1 x 25 mm (19G x 1 in).40 degrees, 8 mm from end.

585040

Olive Tip Cannula.60 x 22 mm (23G x 7/8 in)..33 mm end port. Olive shape tip is2 mm long x 1 mm wide.

585147

Cannula come packaged in a box of 10.