meet USP regulations Cyto Cal Flow Cytometry Calibration and Setup Particles Particle Solutions for USP <729>, <788> and <1027> Ensuring optimal particle counter, sizer and flow cytometer instrument performance is crucial to your product development and ability to comply with ISO and USP <729>, <788> and <1027> regulations. With our uniform, NIST traceable size standards, count controls, calibration and set-up particles, you can • calibrate to ensure the lasers and optics are performing precisely • align to make sure the laser and flow cell is focused • count for absolute cell counting • make sure the instrument is sizing and measuring properly As a result, you can be confident your instruments are consistently delivering the precise and accurate data you require for USP compliance. measure properly
2
Embed
meet USP regulations - Thermo Fisher Scientifictools.thermofisher.com/content/sfs/brochures/FL... · meet USP regulations Cyto Cal Flow Cytometry Calibration and Setup Particles Increase
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
meet USP regulations
Cyto Cal Flow Cytometry Calibration and Setup Particles Increase throughput and precision
Particle Solutions for USP <729>, <788> and <1027>
Ensuring optimal particle counter, sizer and flow cytometer instrument performance is crucial to your product development and ability to comply with ISO and USP <729>, <788> and <1027> regulations. With our uniform, NIST traceable size standards, count controls, calibration and set-up particles, you can• calibrate to ensure the lasers and optics are performing precisely• align to make sure the laser and flow cell is focused• count for absolute cell counting• make sure the instrument is sizing and measuring properlyAs a result, you can be confident your instruments are consistently delivering the precise and accurate data you require for USP compliance.
The chart below shows recommended particles for optimizing instrument performance in accordance with specific USP regulations.
Count ControlsParticles for calibrating and checking particle counter performance and validating results. For more information, request PF1004.1 brochure or visit website.
NIST Traceable Size StandardsParticles for developing, standardizing and validating particle counting and sizing instruments. For more information, request PF1004.1 brochure or visit website.
Rigorous QC standards
Particles for USP Regulatory Compliance
About the USP
The United States Pharmacopeial Convention (USP) is a scientific nonprofit organization that sets standards for the identity, strength, quality, and purity of medicines, food ingredients, and dietary supplements manufactured, distributed and consumed worldwide. In 2007, the USP, European Pharmacopoeia (Ph. Eur) and Japan Pharmacopoeia (JP) harmonized the <788> methods, definitions and limits.
Flow Cytometry ParticlesParticles for calibrating and set, alignment, and absolute cell counting of all makes and brands of flow cytometers. For more information, request PF4001.1 brochure or visit website.