Top Banner
1 Medication Management: New Technology to Reduce Cost and Increase Efficiency By Dan Grady, MEd, RRT, FAARC copyright 2011
25

Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

Aug 19, 2018

Download

Documents

leque
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

1

Medication Management: New Technology to Reduce Cost and

Increase Efficiency

By

Dan Grady, MEd, RRT, FAARC

copyright 2011

Page 2: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

2

Disclosures Relationships with:

CPC, Inc. TherOx, Inc. Outcome Solutions LLC AARC

copyright 2011

Page 3: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

3

Presentation Outline

Background Joint Commission Standards Research Study Results New Solution for Meeting Standards,

Saving Steps, and Cost Savings

copyright 2011

Page 4: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

4

Background: Joint Commission Inspections for Medication Safety

In past, TJC cited Respiratory Therapists for carrying Medications in pockets or fanny packs.

Rationale was that meds were: (1)heated and chemically broke down

(2) not secure

copyright 2011

Page 5: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

5

Background The prohibition against carrying meds in

pockets resulted in more time performing procedure, decreased efficiency, and multiple steps back and forth to med storage machines.

We conducted an original study to determine if RT’s carrying meds in pockets resulted in significant temperature changes compared to med temps in storage (Pyxis) machines.

copyright 2011

Page 6: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

6

Joint Commission 2011 Standards for Medication Management

2. “ The hospital stores medications according to the manufacturers’ recommendations, or in absence of such, according to a pharmacist’s instructions.”

MM.03.01.01 Performance Element: 2 Joint Commission 2011 e-dition

copyright 2011

Page 7: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

7

Manufacturer Recommended Storage Temperatures for RC Medications

Trade Name Generic Name Manufacturer RecommendedStorage Temp Degrees F

Manufacturer RecommendedStorage Temp Degrees C

Albuterol Albuterol Sulfate 36-77 2-25

Atrovent Ipatropium Bromide 59-86 15-30

Duoneb Ipratropium and Albuterol 36-77 2-25

Pulmicort Budesonide 68-77 20-25

Xopenex Levalbuterol 68-77 20-25

copyright 2011

Page 8: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

8

Joint Commission 2011 Standards for Medication Management

4. “The hospital has a written policy addressing the control of medication between receipt by an individual health care provider and administration of the medication, including safe storage, handling, security, disposition, and return to storage.”

MM.03.01.01 Performance Element: 4 Joint Commission 2011 e-ditioncopyright 2011

Page 9: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

9

Joint Commission 2011 Standards for Medication Management

5. “The hospital implements its policy addressing the control of medication between receipt by an individual health care provider and its administration.

MM.03.01.01 Performance Element: 5 Joint Commission 2011 e-dition

copyright 2011

Page 10: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

10

Joint Commission 2011 Standards for Medication Management

4. “The hospital reviews the literature and other external sources for new technologies and best practices.”

MM.08.01.01 Performance Element: 4 Joint Commission 2011 e-dition

copyright 2011

Page 11: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

11

Joint Commission 2011 Standards for Medication Management

Definition of Secure: “In locked containers, in a locked room, or under constant surveillance. “

Glossary for Medication Management Joint Commission 2011 e-dition

copyright 2011

Page 12: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

12

Joint Commission 2011 Standards for Medication Management

1. “The hospital collects data on the performance of its medication management system.”

MM.08.01.01 Performance Element: 1 Joint Commission 2011 e-dition

copyright 2011

Page 13: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

13

Joint Commission 2011 Standards for Medication Management

5. “Based on analysis of its data, as well as review of the literature for new technologies and best practices, the hospital identifies opportunities for improvement in its medication management system .”

MM.08.01.01 Performance Element: 5 Joint Commission 2011 e-dition

copyright 2011

Page 14: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

14

Comparison of Methods for Medication Storage and Transport by RT’s

Recently conducted a research study for medication storage and handling by RT’s.

The temperature of 31 saline samples stored in Pyxis machine was compared to 31 samples of saline transported by RT’s.

Compared temperature in both groups via t-test.

copyright 2011

Page 15: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

15

Scattergram of Temperature Measurements for Pyxis Storage (n =31) compared with RT

Transport of saline samples (n=31).* Note data for both groups > 77 degrees F !

copyright 2011

Page 16: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

16

Comparison of Methods for Medication Storage and Transport: Table Shows Sample Sizes Outside Acceptable Temperature Storage

Range (> 77 degrees F).Both Methods Need Improvement!.

Method Temps > 77 Degrees % Temps > 77 Degrees

Therapist 16 52%

Pyxis 15 48%

copyright 2011

Page 17: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

17

Research Study Implications

Joint Commission will no longer enforce standard that RT’s not carry meds in pockets.

However, per new 2011 standards, RT Departments must (1) have a policy for medication management, and; (2) produce data showing meds are within manufacturer storage guidelines.

How will you comply?copyright 2011

Page 18: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

18

New Technology for Medication Management

We have developed a novel device for transporting medications which is:

Safe Secure Temperature monitored Multi-Medication transport Inexpensive, Lightweight, and saves RT steps

and time.

copyright 2011

Page 19: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

19

IsoThermal Solutions Medipac Device

from: www//OutcomeSolutions.netpatent pending

copyright 2011

Page 20: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

20

IsoThermal SolutionsMedipac Device Components

from: www//OutcomeSolutions.netpatent pending

copyright 2011

Page 21: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

21

IsoThermal SolutionsMedipac Device Assembled

from: www//OutcomeSolutions.netpatent pending

copyright 2011

Page 22: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

22

Comparison of Methods for Medication Storage and Transport: Table Shows Sample Sizes Outside Acceptable Temperature Storage

Range (> 77 degrees F).Medipac was superior to Pyxis and RT Transport.

00Isothermal Medipac

Method Samples with Temps > 77 Degrees (n =31 in each group)

% of Samples in each group with

Temps > 77 Degrees

Therapist 16 52%

Pyxis 15 48%

copyright 2011

Page 23: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

23

Comparatitve Study of IsoThermal Medipac, Pyxis, and RT Transport.

Results: The IsoThermal MediPac device:

1. Maintained 100% of saline samples transported by RT’s for 1 hour within manufacturer recommended guidelines (68- 77 Degrees F). May last up to 6 hours with refrigerated gel pad.

2. Achieved statistically significant differences in temperature compared to (1) Pyxis and (2)RT pocket transport (n = 31. alpha =.05 for all groups, P = 0.0006 and P = 0.0001, respectively).

copyright 2011

Page 24: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

24

Annualized Cost Savings of Retrieving Multiple Medications from Storage

Reduces steps and travel time back and forth to storage machine.

Reduces time by 3 minutes/procedure. At 800 bed medical center, estimated cost

reduction of 155,000/yr by improved efficiency.

Estimated cost savings for 20 NC Hospitals equals 1.6 million dollars/yr.

copyright 2011

Page 25: Medication Management: New Technology to Reduce …isothermalsolutions.com/ToolKit/Medication Management PowerPoint.… · Dan Grady, MEd, RRT, FAARC copyright 2011. 2 Disclosures

25

IsoThermal Solutions Medipac

More information at

http//www.outcomesolutions.net

copyright 2011