WHAT IS MICROPROCESSOR Microprocessor is a chip contains integrated circuit, which receives the signals from the operator, process and gives the output . Microprocessor (µP) controls the entire loco through 4 systems: 1. Excitation control system 2. Propulsion control system 3. Battery charging control system 4. Speed control system
66
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: MEDHA Microprocessor.ppt

WHAT IS MICROPROCESSOR

Microprocessor is a chip contains integrated circuit which receives the signals from the operator process and gives the output

Microprocessor (microP) controls the entire loco through 4 systems

1 Excitation control system

2 Propulsion control system

3 Battery charging control system

4 Speed control system

MEP-660 LOCOMOTIVE MEP-660 LOCOMOTIVE CONTROL SYSTEM CONTROL SYSTEM

Diesel Engine

Governor

Traction Alternator

Rectifier Panel

Power Contactors

Traction Motors

AuxGen

AG Control

Excitation Control

Propulsion Control

Engine Control

Exciter

MICRO PROCESSORCONTROL SYSTEM

TYPES OF MICROPROCESSOR LOCOS

There are two types of microprocessor locomotives in south central railway

1 MEDHA MICROPROCESSOR

2 GE MICROPROCESSOR

TYPES OF MICROPROCESSOR LOCOS

There are two types of microprocessor locomotives in south central railway

1 MEDHA MICROPROCESSOR

2 GE MICROPROCESSOR

MEDHA MICROPROCESSOR

List of Items Removed

1 Rotating machinesAxle Driven Alternator Tacho generator

List of Items Removed

2Control PanelsExcitation Control Panel (EXCP)Engine Control Panel (ECP)Voltage Regulator Panel (VRP)Transition Regulator Panel (TRP)

3Resistor Panels

Wheel slip resistor panel (WSRR1 amp 2)Wheel slip control resistors WR8 WR9 amp WR10Oscillator Voltage Dividing panel (OVDR)Generator Voltage Dividing panel (GVDRVDP)Tacho generator load resistor panel (TGLR)Braking limiting resistor panel (BKER1 amp 2)

4Relays Out of 23 relays 13 relays are eliminated amp 10 relays retained

s no Retained relays

1DMR DMR

2 ERR Renamed as SANDER

3 BSR Renamed as ALRTRB

4 CVR Renamed as CMR

5 TR Renamed as SLBRFSR

6 SR SR

7 BKR1

8 BKR2

9 BKR3

10 ALR1 AFLR

11 ALR2

12 ALR3

13 Timer Relay

14 WSR1

15 WSR2

16 WSR3

17 GR1

18 GR2

19 GFOLR

20 CKR1 Renamed as AGPR

21 CKR2 Renamed as EXPR

22 TDR

23 MVR MVR

5 MISCELLANEOUS ITEMS REMOVED

Transition Excitation Transformer (TET)

Armature Current control reactor (ACCR)

Stabilizing panel (Stab Panel)

Voltage regulator current limiting shunt (VRCLS)

Load ammeter shunt (LAS)

Engine Temperature Switches ndash TS1 TS2 TS3 and ETS

BREAKERS

DISPLAY UNIT

Startstop PB

INDICATION PANEL

Throttle

Load meter

ECS

ALERTER LAMP

DRIVERrsquoS CABIN

99

RBB LPB1 LPB2 DLCB HLPBDEB (Eng)

DEB (Car)

Keep Always ON

CEBRFCB PLPB FPB MPCB AGFB

MB2 MB1

Additional Breakers

NEWLY PROVIDED ITEMSCircuit BreakersThe nomenclatures of all the breakers and switches are almost all same as conventional WDG3A locomotive

Existing Breakers Lighting Circuit

Breakers LPB1 LPB2 HLPB DLCB

MB1 ndash Main Breaker 1MB2 ndash Main Breaker 2AGFB - Auxiliary Generator Field BreakerMFPB1amp2 - Master Fuel Pump BreakersMCB1amp2 - Master Control BreakersFPB ndash Fuel Pump BreakerCEB ndash Crankcase Exhauster BreakerDEB (Eng)- Dust Exhauster Breaker (Eng Side)DEB (Carb) - Dust Exhauster Breaker (Carb Side)RBB - Rectifier Blower BreakerRFCB - Radiator Fan Clutch Breaker (ERF)

MPCBMPCB - - Microprocessor circuit Microprocessor circuit breakerbreaker

PLPBPLPB - - Pre lubrication Pump Pre lubrication Pump BreakerBreaker

DO not switch OFF MPCBDO not switch OFF MPCBSwitch OFF MCB1 amp MCB2 Switch OFF MCB1 amp MCB2

while crankingwhile cranking

Extra (New) BreakersExtra (New) Breakers

EXTRA (NEW )SWITCHESEXTRA (NEW )SWITCHES

lsquolsquoTE LIMITrsquo switch provided TE LIMITrsquo switch provided on the CB panel near the on the CB panel near the compartment light compartment light switchesswitches For normal working keep this For normal working keep this

switch in lsquoswitch in lsquoNORMALrsquo NORMALrsquo position position To limit Tractive effort keep To limit Tractive effort keep

this switch in this switch in lsquoLIMITrsquo lsquoLIMITrsquo position position

WITH TE LIMIT SWITCH IN lsquoLIMITrsquo POSITION WHEN NOT REQUIRED

MAY RESULT IN STALLING OF TRAIN

1 Tractive Effort Limit Switch

1313

2 MOTOR CUTOUT 2 MOTOR CUTOUT SWITCHES SWITCHES

Conventional Rotary type Conventional Rotary type motor cut out switch is motor cut out switch is replaced with 6 individual replaced with 6 individual toggle switches toggle switches

MCOS1 MCOS2 MCOS3 MCOS1 MCOS2 MCOS3 MCOS4 MCOS5 amp MCOS6 MCOS4 MCOS5 amp MCOS6 These switches are located These switches are located

inside the control panel inside the control panel behind the left side door behind the left side door

Normally all these switches Normally all these switches are in are in ON ON (down) position (down) position

Loco Pilot can switch OFF Loco Pilot can switch OFF the required MCOS switches the required MCOS switches up to 5 at a time up to 5 at a time

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 2: MEDHA Microprocessor.ppt

MEP-660 LOCOMOTIVE MEP-660 LOCOMOTIVE CONTROL SYSTEM CONTROL SYSTEM

Diesel Engine

Governor

Traction Alternator

Rectifier Panel

Power Contactors

Traction Motors

AuxGen

AG Control

Excitation Control

Propulsion Control

Engine Control

Exciter

MICRO PROCESSORCONTROL SYSTEM

TYPES OF MICROPROCESSOR LOCOS

There are two types of microprocessor locomotives in south central railway

1 MEDHA MICROPROCESSOR

2 GE MICROPROCESSOR

TYPES OF MICROPROCESSOR LOCOS

There are two types of microprocessor locomotives in south central railway

1 MEDHA MICROPROCESSOR

2 GE MICROPROCESSOR

MEDHA MICROPROCESSOR

List of Items Removed

1 Rotating machinesAxle Driven Alternator Tacho generator

List of Items Removed

2Control PanelsExcitation Control Panel (EXCP)Engine Control Panel (ECP)Voltage Regulator Panel (VRP)Transition Regulator Panel (TRP)

3Resistor Panels

Wheel slip resistor panel (WSRR1 amp 2)Wheel slip control resistors WR8 WR9 amp WR10Oscillator Voltage Dividing panel (OVDR)Generator Voltage Dividing panel (GVDRVDP)Tacho generator load resistor panel (TGLR)Braking limiting resistor panel (BKER1 amp 2)

4Relays Out of 23 relays 13 relays are eliminated amp 10 relays retained

s no Retained relays

1DMR DMR

2 ERR Renamed as SANDER

3 BSR Renamed as ALRTRB

4 CVR Renamed as CMR

5 TR Renamed as SLBRFSR

6 SR SR

7 BKR1

8 BKR2

9 BKR3

10 ALR1 AFLR

11 ALR2

12 ALR3

13 Timer Relay

14 WSR1

15 WSR2

16 WSR3

17 GR1

18 GR2

19 GFOLR

20 CKR1 Renamed as AGPR

21 CKR2 Renamed as EXPR

22 TDR

23 MVR MVR

5 MISCELLANEOUS ITEMS REMOVED

Transition Excitation Transformer (TET)

Armature Current control reactor (ACCR)

Stabilizing panel (Stab Panel)

Voltage regulator current limiting shunt (VRCLS)

Load ammeter shunt (LAS)

Engine Temperature Switches ndash TS1 TS2 TS3 and ETS

BREAKERS

DISPLAY UNIT

Startstop PB

INDICATION PANEL

Throttle

Load meter

ECS

ALERTER LAMP

DRIVERrsquoS CABIN

99

RBB LPB1 LPB2 DLCB HLPBDEB (Eng)

DEB (Car)

Keep Always ON

CEBRFCB PLPB FPB MPCB AGFB

MB2 MB1

Additional Breakers

NEWLY PROVIDED ITEMSCircuit BreakersThe nomenclatures of all the breakers and switches are almost all same as conventional WDG3A locomotive

Existing Breakers Lighting Circuit

Breakers LPB1 LPB2 HLPB DLCB

MB1 ndash Main Breaker 1MB2 ndash Main Breaker 2AGFB - Auxiliary Generator Field BreakerMFPB1amp2 - Master Fuel Pump BreakersMCB1amp2 - Master Control BreakersFPB ndash Fuel Pump BreakerCEB ndash Crankcase Exhauster BreakerDEB (Eng)- Dust Exhauster Breaker (Eng Side)DEB (Carb) - Dust Exhauster Breaker (Carb Side)RBB - Rectifier Blower BreakerRFCB - Radiator Fan Clutch Breaker (ERF)

MPCBMPCB - - Microprocessor circuit Microprocessor circuit breakerbreaker

PLPBPLPB - - Pre lubrication Pump Pre lubrication Pump BreakerBreaker

DO not switch OFF MPCBDO not switch OFF MPCBSwitch OFF MCB1 amp MCB2 Switch OFF MCB1 amp MCB2

while crankingwhile cranking

Extra (New) BreakersExtra (New) Breakers

EXTRA (NEW )SWITCHESEXTRA (NEW )SWITCHES

lsquolsquoTE LIMITrsquo switch provided TE LIMITrsquo switch provided on the CB panel near the on the CB panel near the compartment light compartment light switchesswitches For normal working keep this For normal working keep this

switch in lsquoswitch in lsquoNORMALrsquo NORMALrsquo position position To limit Tractive effort keep To limit Tractive effort keep

this switch in this switch in lsquoLIMITrsquo lsquoLIMITrsquo position position

WITH TE LIMIT SWITCH IN lsquoLIMITrsquo POSITION WHEN NOT REQUIRED

MAY RESULT IN STALLING OF TRAIN

1 Tractive Effort Limit Switch

1313

2 MOTOR CUTOUT 2 MOTOR CUTOUT SWITCHES SWITCHES

Conventional Rotary type Conventional Rotary type motor cut out switch is motor cut out switch is replaced with 6 individual replaced with 6 individual toggle switches toggle switches

MCOS1 MCOS2 MCOS3 MCOS1 MCOS2 MCOS3 MCOS4 MCOS5 amp MCOS6 MCOS4 MCOS5 amp MCOS6 These switches are located These switches are located

inside the control panel inside the control panel behind the left side door behind the left side door

Normally all these switches Normally all these switches are in are in ON ON (down) position (down) position

Loco Pilot can switch OFF Loco Pilot can switch OFF the required MCOS switches the required MCOS switches up to 5 at a time up to 5 at a time

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 3: MEDHA Microprocessor.ppt

TYPES OF MICROPROCESSOR LOCOS

There are two types of microprocessor locomotives in south central railway

1 MEDHA MICROPROCESSOR

2 GE MICROPROCESSOR

TYPES OF MICROPROCESSOR LOCOS

There are two types of microprocessor locomotives in south central railway

1 MEDHA MICROPROCESSOR

2 GE MICROPROCESSOR

MEDHA MICROPROCESSOR

List of Items Removed

1 Rotating machinesAxle Driven Alternator Tacho generator

List of Items Removed

2Control PanelsExcitation Control Panel (EXCP)Engine Control Panel (ECP)Voltage Regulator Panel (VRP)Transition Regulator Panel (TRP)

3Resistor Panels

Wheel slip resistor panel (WSRR1 amp 2)Wheel slip control resistors WR8 WR9 amp WR10Oscillator Voltage Dividing panel (OVDR)Generator Voltage Dividing panel (GVDRVDP)Tacho generator load resistor panel (TGLR)Braking limiting resistor panel (BKER1 amp 2)

4Relays Out of 23 relays 13 relays are eliminated amp 10 relays retained

s no Retained relays

1DMR DMR

2 ERR Renamed as SANDER

3 BSR Renamed as ALRTRB

4 CVR Renamed as CMR

5 TR Renamed as SLBRFSR

6 SR SR

7 BKR1

8 BKR2

9 BKR3

10 ALR1 AFLR

11 ALR2

12 ALR3

13 Timer Relay

14 WSR1

15 WSR2

16 WSR3

17 GR1

18 GR2

19 GFOLR

20 CKR1 Renamed as AGPR

21 CKR2 Renamed as EXPR

22 TDR

23 MVR MVR

5 MISCELLANEOUS ITEMS REMOVED

Transition Excitation Transformer (TET)

Armature Current control reactor (ACCR)

Stabilizing panel (Stab Panel)

Voltage regulator current limiting shunt (VRCLS)

Load ammeter shunt (LAS)

Engine Temperature Switches ndash TS1 TS2 TS3 and ETS

BREAKERS

DISPLAY UNIT

Startstop PB

INDICATION PANEL

Throttle

Load meter

ECS

ALERTER LAMP

DRIVERrsquoS CABIN

99

RBB LPB1 LPB2 DLCB HLPBDEB (Eng)

DEB (Car)

Keep Always ON

CEBRFCB PLPB FPB MPCB AGFB

MB2 MB1

Additional Breakers

NEWLY PROVIDED ITEMSCircuit BreakersThe nomenclatures of all the breakers and switches are almost all same as conventional WDG3A locomotive

Existing Breakers Lighting Circuit

Breakers LPB1 LPB2 HLPB DLCB

MB1 ndash Main Breaker 1MB2 ndash Main Breaker 2AGFB - Auxiliary Generator Field BreakerMFPB1amp2 - Master Fuel Pump BreakersMCB1amp2 - Master Control BreakersFPB ndash Fuel Pump BreakerCEB ndash Crankcase Exhauster BreakerDEB (Eng)- Dust Exhauster Breaker (Eng Side)DEB (Carb) - Dust Exhauster Breaker (Carb Side)RBB - Rectifier Blower BreakerRFCB - Radiator Fan Clutch Breaker (ERF)

MPCBMPCB - - Microprocessor circuit Microprocessor circuit breakerbreaker

PLPBPLPB - - Pre lubrication Pump Pre lubrication Pump BreakerBreaker

DO not switch OFF MPCBDO not switch OFF MPCBSwitch OFF MCB1 amp MCB2 Switch OFF MCB1 amp MCB2

while crankingwhile cranking

Extra (New) BreakersExtra (New) Breakers

EXTRA (NEW )SWITCHESEXTRA (NEW )SWITCHES

lsquolsquoTE LIMITrsquo switch provided TE LIMITrsquo switch provided on the CB panel near the on the CB panel near the compartment light compartment light switchesswitches For normal working keep this For normal working keep this

switch in lsquoswitch in lsquoNORMALrsquo NORMALrsquo position position To limit Tractive effort keep To limit Tractive effort keep

this switch in this switch in lsquoLIMITrsquo lsquoLIMITrsquo position position

WITH TE LIMIT SWITCH IN lsquoLIMITrsquo POSITION WHEN NOT REQUIRED

MAY RESULT IN STALLING OF TRAIN

1 Tractive Effort Limit Switch

1313

2 MOTOR CUTOUT 2 MOTOR CUTOUT SWITCHES SWITCHES

Conventional Rotary type Conventional Rotary type motor cut out switch is motor cut out switch is replaced with 6 individual replaced with 6 individual toggle switches toggle switches

MCOS1 MCOS2 MCOS3 MCOS1 MCOS2 MCOS3 MCOS4 MCOS5 amp MCOS6 MCOS4 MCOS5 amp MCOS6 These switches are located These switches are located

inside the control panel inside the control panel behind the left side door behind the left side door

Normally all these switches Normally all these switches are in are in ON ON (down) position (down) position

Loco Pilot can switch OFF Loco Pilot can switch OFF the required MCOS switches the required MCOS switches up to 5 at a time up to 5 at a time

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 4: MEDHA Microprocessor.ppt

List of Items Removed

2Control PanelsExcitation Control Panel (EXCP)Engine Control Panel (ECP)Voltage Regulator Panel (VRP)Transition Regulator Panel (TRP)

3Resistor Panels

Wheel slip resistor panel (WSRR1 amp 2)Wheel slip control resistors WR8 WR9 amp WR10Oscillator Voltage Dividing panel (OVDR)Generator Voltage Dividing panel (GVDRVDP)Tacho generator load resistor panel (TGLR)Braking limiting resistor panel (BKER1 amp 2)

4Relays Out of 23 relays 13 relays are eliminated amp 10 relays retained

s no Retained relays

1DMR DMR

2 ERR Renamed as SANDER

3 BSR Renamed as ALRTRB

4 CVR Renamed as CMR

5 TR Renamed as SLBRFSR

6 SR SR

7 BKR1

8 BKR2

9 BKR3

10 ALR1 AFLR

11 ALR2

12 ALR3

13 Timer Relay

14 WSR1

15 WSR2

16 WSR3

17 GR1

18 GR2

19 GFOLR

20 CKR1 Renamed as AGPR

21 CKR2 Renamed as EXPR

22 TDR

23 MVR MVR

5 MISCELLANEOUS ITEMS REMOVED

Transition Excitation Transformer (TET)

Armature Current control reactor (ACCR)

Stabilizing panel (Stab Panel)

Voltage regulator current limiting shunt (VRCLS)

Load ammeter shunt (LAS)

Engine Temperature Switches ndash TS1 TS2 TS3 and ETS

BREAKERS

DISPLAY UNIT

Startstop PB

INDICATION PANEL

Throttle

Load meter

ECS

ALERTER LAMP

DRIVERrsquoS CABIN

99

RBB LPB1 LPB2 DLCB HLPBDEB (Eng)

DEB (Car)

Keep Always ON

CEBRFCB PLPB FPB MPCB AGFB

MB2 MB1

Additional Breakers

NEWLY PROVIDED ITEMSCircuit BreakersThe nomenclatures of all the breakers and switches are almost all same as conventional WDG3A locomotive

Existing Breakers Lighting Circuit

Breakers LPB1 LPB2 HLPB DLCB

MB1 ndash Main Breaker 1MB2 ndash Main Breaker 2AGFB - Auxiliary Generator Field BreakerMFPB1amp2 - Master Fuel Pump BreakersMCB1amp2 - Master Control BreakersFPB ndash Fuel Pump BreakerCEB ndash Crankcase Exhauster BreakerDEB (Eng)- Dust Exhauster Breaker (Eng Side)DEB (Carb) - Dust Exhauster Breaker (Carb Side)RBB - Rectifier Blower BreakerRFCB - Radiator Fan Clutch Breaker (ERF)

MPCBMPCB - - Microprocessor circuit Microprocessor circuit breakerbreaker

PLPBPLPB - - Pre lubrication Pump Pre lubrication Pump BreakerBreaker

DO not switch OFF MPCBDO not switch OFF MPCBSwitch OFF MCB1 amp MCB2 Switch OFF MCB1 amp MCB2

while crankingwhile cranking

Extra (New) BreakersExtra (New) Breakers

EXTRA (NEW )SWITCHESEXTRA (NEW )SWITCHES

lsquolsquoTE LIMITrsquo switch provided TE LIMITrsquo switch provided on the CB panel near the on the CB panel near the compartment light compartment light switchesswitches For normal working keep this For normal working keep this

switch in lsquoswitch in lsquoNORMALrsquo NORMALrsquo position position To limit Tractive effort keep To limit Tractive effort keep

this switch in this switch in lsquoLIMITrsquo lsquoLIMITrsquo position position

WITH TE LIMIT SWITCH IN lsquoLIMITrsquo POSITION WHEN NOT REQUIRED

MAY RESULT IN STALLING OF TRAIN

1 Tractive Effort Limit Switch

1313

2 MOTOR CUTOUT 2 MOTOR CUTOUT SWITCHES SWITCHES

Conventional Rotary type Conventional Rotary type motor cut out switch is motor cut out switch is replaced with 6 individual replaced with 6 individual toggle switches toggle switches

MCOS1 MCOS2 MCOS3 MCOS1 MCOS2 MCOS3 MCOS4 MCOS5 amp MCOS6 MCOS4 MCOS5 amp MCOS6 These switches are located These switches are located

inside the control panel inside the control panel behind the left side door behind the left side door

Normally all these switches Normally all these switches are in are in ON ON (down) position (down) position

Loco Pilot can switch OFF Loco Pilot can switch OFF the required MCOS switches the required MCOS switches up to 5 at a time up to 5 at a time

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 5: MEDHA Microprocessor.ppt

4Relays Out of 23 relays 13 relays are eliminated amp 10 relays retained

s no Retained relays

1DMR DMR

2 ERR Renamed as SANDER

3 BSR Renamed as ALRTRB

4 CVR Renamed as CMR

5 TR Renamed as SLBRFSR

6 SR SR

7 BKR1

8 BKR2

9 BKR3

10 ALR1 AFLR

11 ALR2

12 ALR3

13 Timer Relay

14 WSR1

15 WSR2

16 WSR3

17 GR1

18 GR2

19 GFOLR

20 CKR1 Renamed as AGPR

21 CKR2 Renamed as EXPR

22 TDR

23 MVR MVR

5 MISCELLANEOUS ITEMS REMOVED

Transition Excitation Transformer (TET)

Armature Current control reactor (ACCR)

Stabilizing panel (Stab Panel)

Voltage regulator current limiting shunt (VRCLS)

Load ammeter shunt (LAS)

Engine Temperature Switches ndash TS1 TS2 TS3 and ETS

BREAKERS

DISPLAY UNIT

Startstop PB

INDICATION PANEL

Throttle

Load meter

ECS

ALERTER LAMP

DRIVERrsquoS CABIN

99

RBB LPB1 LPB2 DLCB HLPBDEB (Eng)

DEB (Car)

Keep Always ON

CEBRFCB PLPB FPB MPCB AGFB

MB2 MB1

Additional Breakers

NEWLY PROVIDED ITEMSCircuit BreakersThe nomenclatures of all the breakers and switches are almost all same as conventional WDG3A locomotive

Existing Breakers Lighting Circuit

Breakers LPB1 LPB2 HLPB DLCB

MB1 ndash Main Breaker 1MB2 ndash Main Breaker 2AGFB - Auxiliary Generator Field BreakerMFPB1amp2 - Master Fuel Pump BreakersMCB1amp2 - Master Control BreakersFPB ndash Fuel Pump BreakerCEB ndash Crankcase Exhauster BreakerDEB (Eng)- Dust Exhauster Breaker (Eng Side)DEB (Carb) - Dust Exhauster Breaker (Carb Side)RBB - Rectifier Blower BreakerRFCB - Radiator Fan Clutch Breaker (ERF)

MPCBMPCB - - Microprocessor circuit Microprocessor circuit breakerbreaker

PLPBPLPB - - Pre lubrication Pump Pre lubrication Pump BreakerBreaker

DO not switch OFF MPCBDO not switch OFF MPCBSwitch OFF MCB1 amp MCB2 Switch OFF MCB1 amp MCB2

while crankingwhile cranking

Extra (New) BreakersExtra (New) Breakers

EXTRA (NEW )SWITCHESEXTRA (NEW )SWITCHES

lsquolsquoTE LIMITrsquo switch provided TE LIMITrsquo switch provided on the CB panel near the on the CB panel near the compartment light compartment light switchesswitches For normal working keep this For normal working keep this

switch in lsquoswitch in lsquoNORMALrsquo NORMALrsquo position position To limit Tractive effort keep To limit Tractive effort keep

this switch in this switch in lsquoLIMITrsquo lsquoLIMITrsquo position position

WITH TE LIMIT SWITCH IN lsquoLIMITrsquo POSITION WHEN NOT REQUIRED

MAY RESULT IN STALLING OF TRAIN

1 Tractive Effort Limit Switch

1313

2 MOTOR CUTOUT 2 MOTOR CUTOUT SWITCHES SWITCHES

Conventional Rotary type Conventional Rotary type motor cut out switch is motor cut out switch is replaced with 6 individual replaced with 6 individual toggle switches toggle switches

MCOS1 MCOS2 MCOS3 MCOS1 MCOS2 MCOS3 MCOS4 MCOS5 amp MCOS6 MCOS4 MCOS5 amp MCOS6 These switches are located These switches are located

inside the control panel inside the control panel behind the left side door behind the left side door

Normally all these switches Normally all these switches are in are in ON ON (down) position (down) position

Loco Pilot can switch OFF Loco Pilot can switch OFF the required MCOS switches the required MCOS switches up to 5 at a time up to 5 at a time

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 6: MEDHA Microprocessor.ppt

10 ALR1 AFLR

11 ALR2

12 ALR3

13 Timer Relay

14 WSR1

15 WSR2

16 WSR3

17 GR1

18 GR2

19 GFOLR

20 CKR1 Renamed as AGPR

21 CKR2 Renamed as EXPR

22 TDR

23 MVR MVR

5 MISCELLANEOUS ITEMS REMOVED

Transition Excitation Transformer (TET)

Armature Current control reactor (ACCR)

Stabilizing panel (Stab Panel)

Voltage regulator current limiting shunt (VRCLS)

Load ammeter shunt (LAS)

Engine Temperature Switches ndash TS1 TS2 TS3 and ETS

BREAKERS

DISPLAY UNIT

Startstop PB

INDICATION PANEL

Throttle

Load meter

ECS

ALERTER LAMP

DRIVERrsquoS CABIN

99

RBB LPB1 LPB2 DLCB HLPBDEB (Eng)

DEB (Car)

Keep Always ON

CEBRFCB PLPB FPB MPCB AGFB

MB2 MB1

Additional Breakers

NEWLY PROVIDED ITEMSCircuit BreakersThe nomenclatures of all the breakers and switches are almost all same as conventional WDG3A locomotive

Existing Breakers Lighting Circuit

Breakers LPB1 LPB2 HLPB DLCB

MB1 ndash Main Breaker 1MB2 ndash Main Breaker 2AGFB - Auxiliary Generator Field BreakerMFPB1amp2 - Master Fuel Pump BreakersMCB1amp2 - Master Control BreakersFPB ndash Fuel Pump BreakerCEB ndash Crankcase Exhauster BreakerDEB (Eng)- Dust Exhauster Breaker (Eng Side)DEB (Carb) - Dust Exhauster Breaker (Carb Side)RBB - Rectifier Blower BreakerRFCB - Radiator Fan Clutch Breaker (ERF)

MPCBMPCB - - Microprocessor circuit Microprocessor circuit breakerbreaker

PLPBPLPB - - Pre lubrication Pump Pre lubrication Pump BreakerBreaker

DO not switch OFF MPCBDO not switch OFF MPCBSwitch OFF MCB1 amp MCB2 Switch OFF MCB1 amp MCB2

while crankingwhile cranking

Extra (New) BreakersExtra (New) Breakers

EXTRA (NEW )SWITCHESEXTRA (NEW )SWITCHES

lsquolsquoTE LIMITrsquo switch provided TE LIMITrsquo switch provided on the CB panel near the on the CB panel near the compartment light compartment light switchesswitches For normal working keep this For normal working keep this

switch in lsquoswitch in lsquoNORMALrsquo NORMALrsquo position position To limit Tractive effort keep To limit Tractive effort keep

this switch in this switch in lsquoLIMITrsquo lsquoLIMITrsquo position position

WITH TE LIMIT SWITCH IN lsquoLIMITrsquo POSITION WHEN NOT REQUIRED

MAY RESULT IN STALLING OF TRAIN

1 Tractive Effort Limit Switch

1313

2 MOTOR CUTOUT 2 MOTOR CUTOUT SWITCHES SWITCHES

Conventional Rotary type Conventional Rotary type motor cut out switch is motor cut out switch is replaced with 6 individual replaced with 6 individual toggle switches toggle switches

MCOS1 MCOS2 MCOS3 MCOS1 MCOS2 MCOS3 MCOS4 MCOS5 amp MCOS6 MCOS4 MCOS5 amp MCOS6 These switches are located These switches are located

inside the control panel inside the control panel behind the left side door behind the left side door

Normally all these switches Normally all these switches are in are in ON ON (down) position (down) position

Loco Pilot can switch OFF Loco Pilot can switch OFF the required MCOS switches the required MCOS switches up to 5 at a time up to 5 at a time

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 7: MEDHA Microprocessor.ppt

5 MISCELLANEOUS ITEMS REMOVED

Transition Excitation Transformer (TET)

Armature Current control reactor (ACCR)

Stabilizing panel (Stab Panel)

Voltage regulator current limiting shunt (VRCLS)

Load ammeter shunt (LAS)

Engine Temperature Switches ndash TS1 TS2 TS3 and ETS

BREAKERS

DISPLAY UNIT

Startstop PB

INDICATION PANEL

Throttle

Load meter

ECS

ALERTER LAMP

DRIVERrsquoS CABIN

99

RBB LPB1 LPB2 DLCB HLPBDEB (Eng)

DEB (Car)

Keep Always ON

CEBRFCB PLPB FPB MPCB AGFB

MB2 MB1

Additional Breakers

NEWLY PROVIDED ITEMSCircuit BreakersThe nomenclatures of all the breakers and switches are almost all same as conventional WDG3A locomotive

Existing Breakers Lighting Circuit

Breakers LPB1 LPB2 HLPB DLCB

MB1 ndash Main Breaker 1MB2 ndash Main Breaker 2AGFB - Auxiliary Generator Field BreakerMFPB1amp2 - Master Fuel Pump BreakersMCB1amp2 - Master Control BreakersFPB ndash Fuel Pump BreakerCEB ndash Crankcase Exhauster BreakerDEB (Eng)- Dust Exhauster Breaker (Eng Side)DEB (Carb) - Dust Exhauster Breaker (Carb Side)RBB - Rectifier Blower BreakerRFCB - Radiator Fan Clutch Breaker (ERF)

MPCBMPCB - - Microprocessor circuit Microprocessor circuit breakerbreaker

PLPBPLPB - - Pre lubrication Pump Pre lubrication Pump BreakerBreaker

DO not switch OFF MPCBDO not switch OFF MPCBSwitch OFF MCB1 amp MCB2 Switch OFF MCB1 amp MCB2

while crankingwhile cranking

Extra (New) BreakersExtra (New) Breakers

EXTRA (NEW )SWITCHESEXTRA (NEW )SWITCHES

lsquolsquoTE LIMITrsquo switch provided TE LIMITrsquo switch provided on the CB panel near the on the CB panel near the compartment light compartment light switchesswitches For normal working keep this For normal working keep this

switch in lsquoswitch in lsquoNORMALrsquo NORMALrsquo position position To limit Tractive effort keep To limit Tractive effort keep

this switch in this switch in lsquoLIMITrsquo lsquoLIMITrsquo position position

WITH TE LIMIT SWITCH IN lsquoLIMITrsquo POSITION WHEN NOT REQUIRED

MAY RESULT IN STALLING OF TRAIN

1 Tractive Effort Limit Switch

1313

2 MOTOR CUTOUT 2 MOTOR CUTOUT SWITCHES SWITCHES

Conventional Rotary type Conventional Rotary type motor cut out switch is motor cut out switch is replaced with 6 individual replaced with 6 individual toggle switches toggle switches

MCOS1 MCOS2 MCOS3 MCOS1 MCOS2 MCOS3 MCOS4 MCOS5 amp MCOS6 MCOS4 MCOS5 amp MCOS6 These switches are located These switches are located

inside the control panel inside the control panel behind the left side door behind the left side door

Normally all these switches Normally all these switches are in are in ON ON (down) position (down) position

Loco Pilot can switch OFF Loco Pilot can switch OFF the required MCOS switches the required MCOS switches up to 5 at a time up to 5 at a time

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 8: MEDHA Microprocessor.ppt

BREAKERS

DISPLAY UNIT

Startstop PB

INDICATION PANEL

Throttle

Load meter

ECS

ALERTER LAMP

DRIVERrsquoS CABIN

99

RBB LPB1 LPB2 DLCB HLPBDEB (Eng)

DEB (Car)

Keep Always ON

CEBRFCB PLPB FPB MPCB AGFB

MB2 MB1

Additional Breakers

NEWLY PROVIDED ITEMSCircuit BreakersThe nomenclatures of all the breakers and switches are almost all same as conventional WDG3A locomotive

Existing Breakers Lighting Circuit

Breakers LPB1 LPB2 HLPB DLCB

MB1 ndash Main Breaker 1MB2 ndash Main Breaker 2AGFB - Auxiliary Generator Field BreakerMFPB1amp2 - Master Fuel Pump BreakersMCB1amp2 - Master Control BreakersFPB ndash Fuel Pump BreakerCEB ndash Crankcase Exhauster BreakerDEB (Eng)- Dust Exhauster Breaker (Eng Side)DEB (Carb) - Dust Exhauster Breaker (Carb Side)RBB - Rectifier Blower BreakerRFCB - Radiator Fan Clutch Breaker (ERF)

MPCBMPCB - - Microprocessor circuit Microprocessor circuit breakerbreaker

PLPBPLPB - - Pre lubrication Pump Pre lubrication Pump BreakerBreaker

DO not switch OFF MPCBDO not switch OFF MPCBSwitch OFF MCB1 amp MCB2 Switch OFF MCB1 amp MCB2

while crankingwhile cranking

Extra (New) BreakersExtra (New) Breakers

EXTRA (NEW )SWITCHESEXTRA (NEW )SWITCHES

lsquolsquoTE LIMITrsquo switch provided TE LIMITrsquo switch provided on the CB panel near the on the CB panel near the compartment light compartment light switchesswitches For normal working keep this For normal working keep this

switch in lsquoswitch in lsquoNORMALrsquo NORMALrsquo position position To limit Tractive effort keep To limit Tractive effort keep

this switch in this switch in lsquoLIMITrsquo lsquoLIMITrsquo position position

WITH TE LIMIT SWITCH IN lsquoLIMITrsquo POSITION WHEN NOT REQUIRED

MAY RESULT IN STALLING OF TRAIN

1 Tractive Effort Limit Switch

1313

2 MOTOR CUTOUT 2 MOTOR CUTOUT SWITCHES SWITCHES

Conventional Rotary type Conventional Rotary type motor cut out switch is motor cut out switch is replaced with 6 individual replaced with 6 individual toggle switches toggle switches

MCOS1 MCOS2 MCOS3 MCOS1 MCOS2 MCOS3 MCOS4 MCOS5 amp MCOS6 MCOS4 MCOS5 amp MCOS6 These switches are located These switches are located

inside the control panel inside the control panel behind the left side door behind the left side door

Normally all these switches Normally all these switches are in are in ON ON (down) position (down) position

Loco Pilot can switch OFF Loco Pilot can switch OFF the required MCOS switches the required MCOS switches up to 5 at a time up to 5 at a time

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 9: MEDHA Microprocessor.ppt

99

RBB LPB1 LPB2 DLCB HLPBDEB (Eng)

DEB (Car)

Keep Always ON

CEBRFCB PLPB FPB MPCB AGFB

MB2 MB1

Additional Breakers

NEWLY PROVIDED ITEMSCircuit BreakersThe nomenclatures of all the breakers and switches are almost all same as conventional WDG3A locomotive

Existing Breakers Lighting Circuit

Breakers LPB1 LPB2 HLPB DLCB

MB1 ndash Main Breaker 1MB2 ndash Main Breaker 2AGFB - Auxiliary Generator Field BreakerMFPB1amp2 - Master Fuel Pump BreakersMCB1amp2 - Master Control BreakersFPB ndash Fuel Pump BreakerCEB ndash Crankcase Exhauster BreakerDEB (Eng)- Dust Exhauster Breaker (Eng Side)DEB (Carb) - Dust Exhauster Breaker (Carb Side)RBB - Rectifier Blower BreakerRFCB - Radiator Fan Clutch Breaker (ERF)

MPCBMPCB - - Microprocessor circuit Microprocessor circuit breakerbreaker

PLPBPLPB - - Pre lubrication Pump Pre lubrication Pump BreakerBreaker

DO not switch OFF MPCBDO not switch OFF MPCBSwitch OFF MCB1 amp MCB2 Switch OFF MCB1 amp MCB2

while crankingwhile cranking

Extra (New) BreakersExtra (New) Breakers

EXTRA (NEW )SWITCHESEXTRA (NEW )SWITCHES

lsquolsquoTE LIMITrsquo switch provided TE LIMITrsquo switch provided on the CB panel near the on the CB panel near the compartment light compartment light switchesswitches For normal working keep this For normal working keep this

switch in lsquoswitch in lsquoNORMALrsquo NORMALrsquo position position To limit Tractive effort keep To limit Tractive effort keep

this switch in this switch in lsquoLIMITrsquo lsquoLIMITrsquo position position

WITH TE LIMIT SWITCH IN lsquoLIMITrsquo POSITION WHEN NOT REQUIRED

MAY RESULT IN STALLING OF TRAIN

1 Tractive Effort Limit Switch

1313

2 MOTOR CUTOUT 2 MOTOR CUTOUT SWITCHES SWITCHES

Conventional Rotary type Conventional Rotary type motor cut out switch is motor cut out switch is replaced with 6 individual replaced with 6 individual toggle switches toggle switches

MCOS1 MCOS2 MCOS3 MCOS1 MCOS2 MCOS3 MCOS4 MCOS5 amp MCOS6 MCOS4 MCOS5 amp MCOS6 These switches are located These switches are located

inside the control panel inside the control panel behind the left side door behind the left side door

Normally all these switches Normally all these switches are in are in ON ON (down) position (down) position

Loco Pilot can switch OFF Loco Pilot can switch OFF the required MCOS switches the required MCOS switches up to 5 at a time up to 5 at a time

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 10: MEDHA Microprocessor.ppt

Existing Breakers Lighting Circuit

Breakers LPB1 LPB2 HLPB DLCB

MB1 ndash Main Breaker 1MB2 ndash Main Breaker 2AGFB - Auxiliary Generator Field BreakerMFPB1amp2 - Master Fuel Pump BreakersMCB1amp2 - Master Control BreakersFPB ndash Fuel Pump BreakerCEB ndash Crankcase Exhauster BreakerDEB (Eng)- Dust Exhauster Breaker (Eng Side)DEB (Carb) - Dust Exhauster Breaker (Carb Side)RBB - Rectifier Blower BreakerRFCB - Radiator Fan Clutch Breaker (ERF)

MPCBMPCB - - Microprocessor circuit Microprocessor circuit breakerbreaker

PLPBPLPB - - Pre lubrication Pump Pre lubrication Pump BreakerBreaker

DO not switch OFF MPCBDO not switch OFF MPCBSwitch OFF MCB1 amp MCB2 Switch OFF MCB1 amp MCB2

while crankingwhile cranking

Extra (New) BreakersExtra (New) Breakers

EXTRA (NEW )SWITCHESEXTRA (NEW )SWITCHES

lsquolsquoTE LIMITrsquo switch provided TE LIMITrsquo switch provided on the CB panel near the on the CB panel near the compartment light compartment light switchesswitches For normal working keep this For normal working keep this

switch in lsquoswitch in lsquoNORMALrsquo NORMALrsquo position position To limit Tractive effort keep To limit Tractive effort keep

this switch in this switch in lsquoLIMITrsquo lsquoLIMITrsquo position position

WITH TE LIMIT SWITCH IN lsquoLIMITrsquo POSITION WHEN NOT REQUIRED

MAY RESULT IN STALLING OF TRAIN

1 Tractive Effort Limit Switch

1313

2 MOTOR CUTOUT 2 MOTOR CUTOUT SWITCHES SWITCHES

Conventional Rotary type Conventional Rotary type motor cut out switch is motor cut out switch is replaced with 6 individual replaced with 6 individual toggle switches toggle switches

MCOS1 MCOS2 MCOS3 MCOS1 MCOS2 MCOS3 MCOS4 MCOS5 amp MCOS6 MCOS4 MCOS5 amp MCOS6 These switches are located These switches are located

inside the control panel inside the control panel behind the left side door behind the left side door

Normally all these switches Normally all these switches are in are in ON ON (down) position (down) position

Loco Pilot can switch OFF Loco Pilot can switch OFF the required MCOS switches the required MCOS switches up to 5 at a time up to 5 at a time

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 11: MEDHA Microprocessor.ppt

MPCBMPCB - - Microprocessor circuit Microprocessor circuit breakerbreaker

PLPBPLPB - - Pre lubrication Pump Pre lubrication Pump BreakerBreaker

DO not switch OFF MPCBDO not switch OFF MPCBSwitch OFF MCB1 amp MCB2 Switch OFF MCB1 amp MCB2

while crankingwhile cranking

Extra (New) BreakersExtra (New) Breakers

EXTRA (NEW )SWITCHESEXTRA (NEW )SWITCHES

lsquolsquoTE LIMITrsquo switch provided TE LIMITrsquo switch provided on the CB panel near the on the CB panel near the compartment light compartment light switchesswitches For normal working keep this For normal working keep this

switch in lsquoswitch in lsquoNORMALrsquo NORMALrsquo position position To limit Tractive effort keep To limit Tractive effort keep

this switch in this switch in lsquoLIMITrsquo lsquoLIMITrsquo position position

WITH TE LIMIT SWITCH IN lsquoLIMITrsquo POSITION WHEN NOT REQUIRED

MAY RESULT IN STALLING OF TRAIN

1 Tractive Effort Limit Switch

1313

2 MOTOR CUTOUT 2 MOTOR CUTOUT SWITCHES SWITCHES

Conventional Rotary type Conventional Rotary type motor cut out switch is motor cut out switch is replaced with 6 individual replaced with 6 individual toggle switches toggle switches

MCOS1 MCOS2 MCOS3 MCOS1 MCOS2 MCOS3 MCOS4 MCOS5 amp MCOS6 MCOS4 MCOS5 amp MCOS6 These switches are located These switches are located

inside the control panel inside the control panel behind the left side door behind the left side door

Normally all these switches Normally all these switches are in are in ON ON (down) position (down) position

Loco Pilot can switch OFF Loco Pilot can switch OFF the required MCOS switches the required MCOS switches up to 5 at a time up to 5 at a time

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 12: MEDHA Microprocessor.ppt

EXTRA (NEW )SWITCHESEXTRA (NEW )SWITCHES

lsquolsquoTE LIMITrsquo switch provided TE LIMITrsquo switch provided on the CB panel near the on the CB panel near the compartment light compartment light switchesswitches For normal working keep this For normal working keep this

switch in lsquoswitch in lsquoNORMALrsquo NORMALrsquo position position To limit Tractive effort keep To limit Tractive effort keep

this switch in this switch in lsquoLIMITrsquo lsquoLIMITrsquo position position

WITH TE LIMIT SWITCH IN lsquoLIMITrsquo POSITION WHEN NOT REQUIRED

MAY RESULT IN STALLING OF TRAIN

1 Tractive Effort Limit Switch

1313

2 MOTOR CUTOUT 2 MOTOR CUTOUT SWITCHES SWITCHES

Conventional Rotary type Conventional Rotary type motor cut out switch is motor cut out switch is replaced with 6 individual replaced with 6 individual toggle switches toggle switches

MCOS1 MCOS2 MCOS3 MCOS1 MCOS2 MCOS3 MCOS4 MCOS5 amp MCOS6 MCOS4 MCOS5 amp MCOS6 These switches are located These switches are located

inside the control panel inside the control panel behind the left side door behind the left side door

Normally all these switches Normally all these switches are in are in ON ON (down) position (down) position

Loco Pilot can switch OFF Loco Pilot can switch OFF the required MCOS switches the required MCOS switches up to 5 at a time up to 5 at a time

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 13: MEDHA Microprocessor.ppt

1313

2 MOTOR CUTOUT 2 MOTOR CUTOUT SWITCHES SWITCHES

Conventional Rotary type Conventional Rotary type motor cut out switch is motor cut out switch is replaced with 6 individual replaced with 6 individual toggle switches toggle switches

MCOS1 MCOS2 MCOS3 MCOS1 MCOS2 MCOS3 MCOS4 MCOS5 amp MCOS6 MCOS4 MCOS5 amp MCOS6 These switches are located These switches are located

inside the control panel inside the control panel behind the left side door behind the left side door

Normally all these switches Normally all these switches are in are in ON ON (down) position (down) position

Loco Pilot can switch OFF Loco Pilot can switch OFF the required MCOS switches the required MCOS switches up to 5 at a time up to 5 at a time

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 14: MEDHA Microprocessor.ppt

SENSOR S amp LOCATION

Current sensors(14) --- provided at front panelVoltage sensors (5) --- provided at back panelTemperature sensors(3) --- Two provided in Expresser room and

one is provided in back panelPressure sensors(5) --- provided at nose compartmentSpeed sensors(7) --- six connected to each TM and one connected (ESS) to left cam gear cover

ENGINE SPEED SENSOR (ESS)

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 15: MEDHA Microprocessor.ppt

VCD Isolation switch

RELAYSGR1amp2 Cut out switch

ADBS4 Nos

CONTROL UNIT

MICRO PROCESSOR FRONT PANNEL

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 16: MEDHA Microprocessor.ppt

MICRO PROCESSOR CONTROL UNIT

bullThis is the main control equipment in the Microprocessor control system

bullThis is located at the Front panel in the place of ECP

bullThe total control system is functionally divided into different modules

bullThese modules are dustproof amp plug in type cards for easy replacement

bullThe connectors of these modules are unique They can not be inserted at wrong place

bullIt is having 19 cards

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 17: MEDHA Microprocessor.ppt

MEDHA MICRO PROCESSOR DISPLAY UNIT

It is provided at left side of ECS switch on the control panel Display unit is the main interface between the user and the equipment It displays group wise parameters of the locomotive as selected by driver user It displays fault messages Digital inputs and outputs can be tested through the unit

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 18: MEDHA Microprocessor.ppt

Main MenuMain Menu

2) Display Mode

4) Exit

1) Faults

3) Test Mode

Faults - Submenu

1 View Faults2 Clear Faults

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 19: MEDHA Microprocessor.ppt

2121

View Faults - SubmenuView Faults - SubmenuThe registered Faults at run time will be displayed The registered Faults at run time will be displayed

User can navigate through the faults using down User can navigate through the faults using down arrow till the following message is displayedarrow till the following message is displayed

lsquoNo More Faults Press Menu Key to exitrsquo

MENU

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 20: MEDHA Microprocessor.ppt

Clear Faults - SubmenuClear Faults - Submenu

The registered Faults at run time will be displayed User can navigate through the faults using down arrow key and clear the faults by pressing lsquo0rsquo key Till the following message is displayed

Use lsquo0rsquo key to Clear

Depending upon the level of the fault the display prompts pass code for some faults to clear them After entering the valid pass code the fault can be cleared

No More Faults Press Menu Key to exit

MENU

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 21: MEDHA Microprocessor.ppt

Display Mode SubmenuDisplay Mode Submenu

1 Excitation

2 Auxiliary

3 Wheel Slip

4 Mixed

MENU

5 Driver Display6 MCBG status

7 Collective Data8 Digital inputs

MENU

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 22: MEDHA Microprocessor.ppt

Display Mode SubmenuDisplay Mode Submenu

9 Digital Outputs10 HP status

MENU

Test ModeTest Mode

NOT APPLICABLE TO LOCO PILOTS

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 23: MEDHA Microprocessor.ppt

DRIVER DISPLAY

The Driver default display has got three screens

1 IDLE Screen2 Motoring Screen3 Braking Screen

Respective screens are changed automatically based on the control stand signals while the locomotive operation is being set by the Driver

In each screen relative parameters are displayed as shown below

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 24: MEDHA Microprocessor.ppt

ADB(Analog distribution box)

There are 4 Analog Distribution BoxesThese are located at Front panel in the place of VRPTRP

Each ADB Unit generates isolated low voltage source required for the sensors connected to it from the locomotive control voltage of 72V

Each ADB can handle 8 analog inputs from various sensors and transmit them to the Control unit

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 25: MEDHA Microprocessor.ppt

RDB(RPM Distribution box)

bullRPM Distribution Unit is similar to the Analog Distribution Unit but handles RPM signals

bullThis is located at Front panel in the place of VRPTRP

bullAll the six traction motor RPM sensors are connected to this RDB

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 26: MEDHA Microprocessor.ppt

ADDITIONAL FEATURES WITH MEP-6601 Limitation of Power to 4th notch with Failure of Dust Exhauster BreakersFailure of dust exhauster motors clog the filters and Quantity of inlet air is reduced Hence the power is limited to 4th notch along with a warning message if the notch above 4th notch

2 Limitation of Power to 4th notch with Failure of RBB or Diode HOTFailure of RBB result in no cooling to power rectifier Similarly if amount of cooling to Rectifier diodes is less due to ay reasons the diodes become HOT In order to safeguard the power rectifier the engine power is restricted to 4th notch

3 Cold Engine based loadingSoon after cranking the engine speed is restricted based on the lube oil temperature till the lube oil temperature is raised up to 60 degcent To improve lubrication

4 Power De-ration from T3 setting to T4 setting (90 to 95 degCent)The engine power is de-rated by 20 of the notch power for every degree raise from 90 deg Onwards

5 8th notch RPM at hottest TemperatureWhen the Engine temperature reached to T4 setting (95 Deg Cen) Engine RPM is raised to 8th notch automatically by cutting of power for faster cooling of engine

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 27: MEDHA Microprocessor.ppt

6LOW IDLE FEATURE

When the locomotive is in IDLE for more than 10 minutes the engine RPM is reduced to 350 by energising AV and DV for reducing the fuel oil consumption This is posssible only with governors having this option

7Built in Auto switching ON Flasher lights with Simplified circuit

8Self Load box Testing

9Ambient temperature based battery charging

10Event recorder

11Prelubrication

12MULTI RESET VIGILANCE CONTROL DEVICE One VCD reset push button is provided on the control desk near Master handle

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 28: MEDHA Microprocessor.ppt

MULTI RESET VIGILANCE CONTROL DEVICE

WHY VCD

To stop the train If driver is INCAPACITATED An intelligent vigilance control device with multi-reset feature has

been provided to stop the train if the driver is incapacitated

1048714 The device alerts the driver for every 60 seconds before stopping train If the driver is not alert incapacitated VCD applies there by Engine will come to Idle and penalty brakes will be applied and the train stops

1048714 One VCD alerting lamp provided on each control desk near LED indication panel

1048714 One VCD reset push button is provided on the control desk near master handle

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 29: MEDHA Microprocessor.ppt

VCD disable unit is provided in the Control PanelPenalty brake application Valve is provided in nose compartment

VCD STARTS FUNCTION

Soon after circuit breakers MB1 MB2 MPCB MFPB1 MFPB2 MCB1 ampMCB2 are switched ON and BCP is less than 21 Kg Sqcm

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 30: MEDHA Microprocessor.ppt

VCD DOES NOT FUNCTION

If BCP is more than 21 KgSqcm and Loco speed is zero

What VCD do before Penalty BrakesVCD alerts the driver once in every 60 seconds through a Blinking LEDif none of the following activities are performed with in 60 sec1048714 Increase Decrease notch1048708 Application Release of A91048708 Application release of DB1048708 Change of DB level1048708 Operation of GF switches1048708 Change of RH position1048708 Operation of Horn buttons1048708 Operation of Sander buttons1048708 Pressing of VCD reset button

What Driver has to doPerform any of the following loco operations as required or Press VCDRESET button to suppress warning lamp

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 31: MEDHA Microprocessor.ppt

What if Driver does not respond to VCD warnings

1048708 The Blinking LED continues for 17 seconds1048708 After 17 seconds a buzzer is switched ON along with Blinking LED1048708 A message lsquo 2019 - VCD time out Press VCD reset switchrsquo is displayed on the screen1048708 The blinking LED and buzzer continues for another 17 seconds

What if Driver does not respond up to 94 seconds

The MEP-660 assumes that the driver is dead incapacitated and appliesPenalty Brakes after 94 (60+17+17) seconds and the following changes takesplace in the locomotive1 A message lsquo2301 - VCD Applied Penalty Brakesrsquo will be displayed on the Display Panel2 VCD counter is increased by 13 Buzzer is switched OFF4 LED continue to blink for another 35sec5 BP is reduced to 28 KgSqcm6 Loco Formation brakes are applied7 Engine speed is brought to IDLE8 GF power contactor is dropped out9 Power contactors are dropped out after Master handle brought to IDLE

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 32: MEDHA Microprocessor.ppt

FOR RELEASING THE PENALTY BRAKES

1 Bring the Throttle to IDLE2 Wait till the blinking LED is OFF3 Wait till the Loco speed is reduced to zero4 Press VCD RESET button

WHILE WAITING FOR SIGNAL IN THE YARD

Apply loco brakes with SA9 to suppress VCD function Ensure BCP is morethan 21 kgSqcm

NOTEbull Always press lsquoVCD resetrsquo switch whenever lsquoVCD LEDrsquo is blinkingbull Donrsquot forget to apply loco brakes while loco is in stand

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 33: MEDHA Microprocessor.ppt

THE microP LOCOMOTIVE IS WORKING AS REAR LOCOMOTIVE IN MU OPERATION

1 While the locomotive is working as rear loco in MU operation the VCD is not required2 The circuit breakers MCB1 and MCB2 which are available on control desks of Rear Loco should be switched off after making MU set up3 The VCD function is automatically isolated in rear loco and the display shows lsquoVCD in MUrsquo message in the 4th line indicating the status of the VCD4 otherwise ndash What happens 5 Rear loco does not respond to lead loco signalsVCD counterAn incrementing counter by name lsquoVCD Counterrsquo is added in the displayscreen This parameter is visible only when the loco is in idle position Thecount is incremented by one as and when the VCD applies penalty brakeindicating that the driver is not alert

NOTE Please note the reading of this lsquoVCD Counterrsquo on the display unit andrecord the same in the driverrsquos logbook while taking over charge of thelocomotive

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 34: MEDHA Microprocessor.ppt

TO ISOLATE VCD

1 In case of continuous penalty brake application due to any reason then Break the glass and switch off the VCD disable switch provided in the control panel to disable VCD function

2 The MEP-660 records a message lsquoOperator disabled VCDrsquo in the fault log with date and time

BP dropping continuously throughrdquo VCDrdquo magnet valve

Close the cut out cock side of the lsquoVCD magnet valversquo if air is leakingfrom the VCD magnet valve

Warning

After Closing VCD coc even though VCD applies penalty Loco brakes will not come but Engine will come to Idle

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 35: MEDHA Microprocessor.ppt

INDICATIONS ON CONTROL DESK

SAFETY ALARM INDICATIONS CIRCUIT BREAKER PANEL

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message A warning messageldquo2000 - No Battery charging due to major faultsrdquois displayed on the screen with buzzer for 30 seconds for every 10 minutes as long as battery voltage is greater than 60V

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 36: MEDHA Microprocessor.ppt

Indication AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message Actually there are different faults for batteries not charging A relevant message concerned to the fault is logged first After logging the fault message the above message is displayed to driver as warning since loco is running on batteries

1062 ndash Battery voltage is high1063 ndash AG field drive short1141 ndash AG output high fault1142 ndash Battery charging current high1143 ndash AG output over current fault1144 ndash AG field over current1145 ndash AG output open circuit fault1146 ndash AG field circuit open or short

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 37: MEDHA Microprocessor.ppt

Indication

AGFail

Reasons for indication

Aux Generator failed to develop voltage and Batteries are not charging

Message If the voltage is less than 60V a warning message lsquolsquo1061 - Battery Voltage is Low Warning Loco may stallrsquo with buzzer sound for 30 seconds for every 10 minutes

Action by Loco Pilot

Check for tripped AGFB and MB1 breakers Check for tightness of ESS connector at ESS

Reset message

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 38: MEDHA Microprocessor.ppt

Indication

CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message ldquo1029 ndash Cranking Contactor CK Stuck ClosedRestrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlarm gong switched on continuously

Action by Loco Pilot

Normally at the end of each cranking this indication glows for about 15 seconds If the indication does not stop after 2 to 3 seconds check up for any welding of CK1CK2CK3 tipsShutdown the engine Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVEREDs

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 39: MEDHA Microprocessor.ppt

Indication CK TIP WELD

Reasons for indication

Main tips of Cranking contactor CK1CK2CK3 got welded

Message In case engine did not crank but cranking tips of any cranking contactor CK1CK2CK3 are welded and the driver tries to re-crank without noticing the above warnings a second message will be displayed ldquo2029 - Cranking Contactor Stuck ClosedRestrictions Cranking Prohibitedrdquo5 Sec buzzer will be given

Action by Loco Pilot

Open battery Knife switch Separate the welded tips with a wooden stick After the tips are separated Alarm bell stops and the reset message is displayed

Reset message

Cranking contactor stuck closed FAULT RECOVERED

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 40: MEDHA Microprocessor.ppt

Indication Over Load

Reasons for indication

Tr Alternator Field current is more than 280 Amps

Message ldquo1027-Alternator Field over current FAULT Restrictions motoring prohibited dynamic brake prohibitedrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Bring throttle to IDLE The fault is reset automatically Reset message is displayed Trouble shoot as per GFOLR trip in normal WDG3A locomotives

Reset Message

Alternator field over current reset for 5 seconds

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 41: MEDHA Microprocessor.ppt

Over load Fault

If the fault is existingThe fault is logged again

Auto reset is permitted up to 3 times within 1 hour

There after manual reset has to be done

If the fault is occurred more than 3 times contact shed for further adviceDo not forget to write in the repair book

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 42: MEDHA Microprocessor.ppt

Indication DEB (Eng)

Reasons for indication

DEB (Eng) circuit breaker tripped Switched OFF

Message ldquo1155 - DEB Engine Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Eng) circuit breaker

Reset Message

ldquoDEB engine breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication DEB (Car)

Reasons for indication

DEB (Car) circuit breaker tripped Switched OFF

Message ldquo1156 - DEB Car body Breaker OffrdquoAlarm gong switched on for 30 seconds

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the DEB (Car) circuit breaker

Reset Message

ldquoDEB car body breaker on now Breaker fault recoveredrdquo for 5 seconds

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 43: MEDHA Microprocessor.ppt

Indication

CEB Fail

Reasons for indication

CEB circuit breaker tripped Switched OFF

Message ldquo2022 - Switch ON CEB Breakerrdquo with buzzer sound after 25 secondsIf the CEB breaker is not switched ON with in 30 minutes A message ldquoCEB Breaker OFFrdquois logged in fault data

Action by Loco Pilot

Check up any problem with motor and trouble shoot as per tripped breaker in WDG3A Switch ON the CEB circuit breaker

Reset Message

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 44: MEDHA Microprocessor.ppt

Indication

Low Lube Oil

Reasons for indication

LLOB in Woodward Governor tripped

Message lsquo1005 ndashLLOB trip ndash Reset plunger Restrictions Cranking Prohibitedrsquorsquo Alarm bell is switched ON continuously till LLOB is resetThe fault code is 1004 if the ldquoLLOB tripped in Engine OFFrdquo conditionIf the fault is existing the fault is logged again

Action by Loco Pilot

Reset LLOB in Gov Reset fault as per the reset procedure or wait for 20 seconds after LLOB is reset till the system recovers from faultRe crank after the above reset

Reset Message

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 45: MEDHA Microprocessor.ppt

Indication HOT Engine

Reasons for indication

Water temperature is more than 90o C

Message ldquo2008 - Warning ENGINE Temperature High Reduce Powerrdquo for 5 seconds Alarm bell is switched ON continuously till temperature is less than 85o C

Action by Loco Pilot

If possible do fast pumping manually OtherwisePower is de-rated by 20 per every degree of temperature raise from 90oC onwardsDriver can work with reduced power up to 95o C

Reset Message

-

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 46: MEDHA Microprocessor.ppt

Indication

HOT Engine

Reasons for indication

Water temperature is more than 95ordm C

Message ldquo1006 - HOT ENGINE Canrsquot Power UP Restrictions Motoring Prohibited Dynamic Brake ProhibitedrdquoAlong with buzzer continuously in addition to alarm bellGF and power contactors are dropped out Engine RPM is automatically raised to 8th notch irrespective of notch positionIf reset button is pressed or after 30 secondsldquo2026 - HOT ENGINE Canrsquot Power UPRestrictions Engine is running at 8th notch Motoring Prohibited Dynamic Brake Prohibitedldquo along with buzzer

Action by Loco Pilot

Apply train brakes Wait till the water temperature is reduced below 90oC Bring the master handle to IDLE Engine speed reduces to IDLE automatically Buzzer and message stops

Reset Message

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 47: MEDHA Microprocessor.ppt

Indication Ground LED

Reasons for indication

TANGI detected power circuit is grounded

Message ldquo1007 - Power Circuit Ground Restrictions Motoring Prohibited Dynamic Brake Prohibited Engine IDLErdquo with continuous alarm bell till throttle is brought to IDLEPower is cut off Engine RPM is brought to IDLE Power contactors and GF are dropped out

Action by Loco Pilot

Bring the throttle to IDLE and wait for 15 SecThe fault is cleared automaticallyPERFORM THE CHECKS AS PER THE CONVENTIONAL WDG3A LOCO

Reset Message

Power circuit ground fault recovered for 5 seconds

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 48: MEDHA Microprocessor.ppt

Indication

Wheel Slip LED

Reasons for indication

MEP 660 sensed difference of wheel RPM and one of the wheel is physically slipping from track Power is reduced to 85

Message Sander relay operated Auto sanding is appliedWhen power reduction is 40 then a Fault messagelsquo2582-High wheel slip occurredrsquo is recorded

Action by Loco Pilot

Do not reduce the notch as long as loco is moving If wheel slip is continuous ensure working of sanders Operate like conventional WDG3A loco

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 49: MEDHA Microprocessor.ppt

Indication

VCD Lamp

Reasons for indication

Loco Pilot did not performed any of the loco operations or not pressed VCD reset switch with in 60 seconds

Message ldquoVCD time out Press VCD resetrdquo message is displayed after 17 seconds along with buzzer

Action by Loco Pilot

PRESS VCD RESET BUTTON ONCE or perform any loco operations as listed under VCD explanation

Reset Message

--

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 50: MEDHA Microprocessor.ppt

Indication

AFL LED

Reasons for indication

Un authorized BP reduction

Action by Loco Pilot

Ensure there is no unauthorized BP reduction due to train partingIf so act as per the rail road rules applicableIf not Press AFL reset switch to reset flasher lights

Reset Message

--

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 51: MEDHA Microprocessor.ppt

Indication

Air Flow LED

Reasons for indication

Reduction in BP due to passenger chain pulling or excessive leakages

BP charging rate is more as sensed by Air flow measuring valve

Message --

Action by Loco Pilot

Act as in the case of conventional WDG3A

Reset Message

--

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 52: MEDHA Microprocessor.ppt

TROUBLE SHOOTING ON MEDHA MICRO PROCESSOR LOCOS

Sl no

Case Probable causes Action to be taken

1 Engine not cranking

1Fuel pump motor not working Fuel oil pressure zero 2CK1CK2not picking up3Engine not cranking4Low water level

1 a Ensure MB1MB2and FPB breakers are in lsquoON rsquopositionb Ensure FPC contactor energizedc Ensure fuel pump motor is workingd Ensure fuel oil pressure buildup If not Check fuel oil system 2 a Keep ECS in idle positionb Ensure start button connections and operationc Ensure CKC is picking upd Ensure both control stand MU switches and keep in run positione Ensure CK1CK2 are picking up 3 a Ensure OSTA in tripped conditionb Ensure fuel rack control shaft connectionc Ensure LLOB in tripped condition4 a Ensure water level indication showing indicationb Ensure water level in the expansion tank

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 53: MEDHA Microprocessor.ppt

02

No Battery charging

1AGFB breaker is in OFFTripped 2MB1 breaker is in OFFTripped

1 Ensure AGFB breaker is in lsquoON position if tripped switch lsquoOFFrsquo and switch lsquoONrsquo AGFB breaker2Ensure MB1 breaker is in ON position if Tripped switch lsquoOFFrsquo and switch lsquoONrsquo MB1 breaker

03

Throttle not responding

1 DMR not picking up2 Control stand may be defective3 Defective Governor2 ECS is in idle position3COBERS breakers are OFFTripped4 Governor defective

1a Ensure MCB1MCB2 are in lsquoONrsquo position if Tripped switch rsquoOFFrsquo and switch lsquoONrsquob Ensure Brake pipe Pressure and it should be 5kgcm2c Ensure PCS connections and DMR energized2Try with other control stand3a Check Amphenol plug tightnessb Ensure PCS COC in open positionc Ensure the tightness of control drum couplers 2 Keep ECS in run position 3 Switch lsquoOFFrsquo and switch lsquoONrsquo ERS and COB breakers4 Check Am phenol plug tightness

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 54: MEDHA Microprocessor.ppt

04

Load meter not responding

1GF contactor not picking up

2Power ontactors not picking up

3 Rectifier Blower motor not working condition4 No flash from GF contactor

5 Power circuit ground

1 a Ensure PCR is in energized conditionb Ensure ECS is in run positionc Ensure GFB breaker in lsquoONrsquo positiond Ensure both control stands GF switches are in lsquoONrsquo positione Ensure BKT is in motoring positionf Ensure REV is in forwardreverse direction2 a Ensure control air pressure is 5kgcm2if not check N1 reducing valve COC it should be in open positionb Check power contactors air pipes for any leakages3 a Ensure RBB breaker is in lsquoONrsquo positionb Ensure rectifier Blower motor working condition4 a Check Traction Alternator carbon Brushes and slip ring conditionb Check Exciter Generator connection and carbon brushes conditionc Check power Rectifier cables condition and any abnormalities5 a Open GR seal and clear the section GR seal available on back side panelb Contact shed for advise

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 55: MEDHA Microprocessor.ppt

05

Engine come to IDLE

1 PCR (DMR) not picking up2Control stand my be defective3 ERS breaker tripped4Defective Governor5Cold engine6If ldquoGDM RU is badrdquo fault logged

1 Ensure Brake pipe pressure and it should be 5kgcm2 Ensure PCR energized2Try with other control stand3Switch lsquoOFFrsquo and switch lsquoONrsquo ERS breaker4Check amphinal plug tightness5Wait up to lube oil temperature raises to 60 degree centigrade6Reset the fault as per resetting procedure pasted in the cab

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 56: MEDHA Microprocessor.ppt

06 Loco power reduced to 4th notch

1High temperature of water and lube oil2Hot diodes-Rectifier Blower breaker tripped or Rectifier Blower failed or breaker is in OFF position

1Chcek water temperature and Radiator fan working Switch on ERF breaker Ensure water level in expansion tank2Switch lsquoOFFrsquo and switch lsquoONrsquo RBB breaker and ensure rectifier blower is working

07 Loco power reducing

1Wheel slip due to pinion slipped2High temperature of water and lube oil

1Ensure Traction motors free rotation Isolate traction motor one by one2Ensure water level in expansion tank Check water temperature and radiator fan working Switch lsquoONrsquo ERF breaker if available

08 Wheel slip on traction motor-nolocked axle on traction motor-no

1Traction motor speed sensor may faulty2Traction motor may be defective

1Ensure Traction motor free rotation Isolate traction motor one by one

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 57: MEDHA Microprocessor.ppt

09 Loco shutting down with LLOB tripping(loco shutting down low oil pressure message on DID panel)

1Lube oil pressure may be less2LLOB button tripped in Governor3OSTA tripped4Governor oil less

1Check lube oil level and Lube oil pressure2Reset the LLOB button in Governor3Reset OSTA handle4Ensure Governor oil level

10 Loco shut down without any indication

1OSTA tripped2Fuel oil pressure less or zero3Governor oil less4 Any breaker tripped

1Reset OSTA handle2Check fuel pump motor working3Ensure Governor oil level4Switch lsquoOFFrsquo all breakers and switch lsquoONrsquo and crank the loco

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 58: MEDHA Microprocessor.ppt

11 VCD(vigilance control device) LED light lsquoONrsquo

1VCD LED light lsquoONrsquo2Hooter sound is coming3BP pressure drops to zero

1If not operates any one of the throttle handle or sand button or horn button or A9 handle up to 60 seconds VCD light will lsquoONrsquo Press VCD reset button or any of the above and ensure VCD light lsquoOFFrsquo2Press VCD reset button and ensure hooter sound lsquoOFFrsquo3Bring the throttle to idle Keep the reverser handle in neutral position press VCD reset button and hold it till BP pressure builds up or switch lsquoOFFrsquo VCD toggle switch Ensure BP pressure builds up

12 VCD (vigilance control device) is in lsquoOFFrsquo

1Warning Alerter disabled message will come on DID panel

1Nothing will affect the normal operation

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 59: MEDHA Microprocessor.ppt

ADVANTAGES OF MICROPROCESSOR

Switches Breakers and Operational procedures are same as conventional locomotive for easy handling to drivers

1 Very Low intervention by the driver during faultsTrouble shooting activities by driver is simplified

2 No reset of GR1 GR2 and GFOLRThese items are not available Reset procedure is simplified

3 No need to maintain Timings specified in yellow zone of Load MetermicroP automatically reduces the excitation to safe zone if timings are exceeded

4 No need to regulate dynamic brake high speedsmicroP automatically restricts the Load meter to safe zone based on the loco speed

5 No slackness of microP cards on run6 More than one traction motor can be isolated As against single Tr Motor

in conventional locos7 2S-2P mode of operation in case of any Trmotor isolation to provide

more starting torque As against direct parallel mode of operation in conventional loco

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco

Page 60: MEDHA Microprocessor.ppt

8 Automatic reduction of transition speed in case of any Tr Motor isolation for quick acceleration As against no transition in conventional loco

9 Automatic power limitation based on TMs isolated and mode of transition to safe guard Traction motors

10 Detailed fault indications with audio visual warnings to driver As against 10 to 15 LED indications

11No confusion to driver in case of wheel slip Only Mechanical wheel slip is indicated as wheel slip

12In case of locked axle system indicates clearly which wheel is locked Driver has to identify the locked axle as conventional locomotive

13Detailed LED indications on control unit to identify the wiring equipment faults No such facility in conventional loco