Red Head Mechanical Anchoring Systems The Red Head product line has long been respected by both contractors and specifiers in the construction industry. Because ITW Ramset/Red Head proactively gets Red Head products specified before the job starts, contractors save time and money, plus the hassle of getting products approved. We will continue to pursue code approvals for specific anchor usages. Red Head has also been on the forefront of concrete anchoring industry innovation and development. For example, we Red Head is committed to providing contractors with quality products and developing new products to meet the demands of contractors worldwide. Since 1910, the brand trusted by the construction industry for quality, innovation and engineering support | developed the first anchor (the Self-Drill in 1910) | developed the fully-threaded Trubolt ® Wedge anchor with a stainless steel clip | developed the lipped Multi-Set II ® anchor | helped develop (as part of ITW) markets for Tapcon ® and E-Z Ancor ™ | were one of the first manufacturers to achieve ISO9002 certification
52
Embed
Mechanical Anchoring Systems · PDF fileMechanical Anchoring Systems ... (LDT ™) Self-Threading ... The exposed end of the anchor is stamped to identify anchor length
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Red HeadMechanical Anchoring Systems
The Red Head product line has long been respected by both contractors and specifiers in the constructionindustry. Because ITW Ramset/Red Head proactivelygets Red Head products specified before the job starts,contractors save time and money, plus the hassle of getting products approved. We will continue to pursuecode approvals for specific anchor usages.
Red Head has also been on the forefront of concrete anchoring industry innovation and development.
For example, we
Red Head is committed to providing contractors withquality products and developing new products to meetthe demands of contractors worldwide.
Since 1910, the brand trusted by the construction industry for quality, innovation and engineering support
| developed the first anchor (the Self-Drill in 1910)
| developed the fully-threaded Trubolt ® Wedge anchor with a stainless steel clip
| developed the lipped Multi-Set II® anchor
| helped develop (as part of ITW) markets for Tapcon® and E-Z Ancor™
| were one of the first manufacturers to achieve ISO9002 certification
58 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Selection Guide
Anchors for Concrete Applications
Diameter: 1/4 – 1
Length: 1-3/4 – 12
Diameter: 1/4 – 3/4
Length: 5/8 – 6-1/4
Diameter: 1/4 – 3/4
Length: 1-3/4 – 6-1/4
■ Fully-threaded
■ Length ID head stamped
■ Stainless steel clip
■ Through-fixture fastening
■ Concrete, block and brick
■ Many choices of head styles
■ Through-fixture fastening
■ Available in 304 stainless steel
Diameter: 3/8 – 3/4
Length: 2 – 7
■ Special design clamps down base plates
■ Finished head, heavy duty sleeve anchor
■ Removable
■ Available in carbon steel and 316 stainless steel
■ RM: Flanged body to keep anchor flush with surface of concrete
■ RL: Non-flanged body for recessed setting
■ RX: Designed for hollow core and post tension concrete
■ CL: Designed for one-sided forming, accepts coil rodRM RL RX CL
Multi-Set II®Drop-In Anchors
Diameter: 3/8 and 1/2
Length: 1-3/4 – 5
■ Anti-rotation serrated washer
■ Extra large hex washer head
■ Length ID head stamped
■ GRD2000™ exterior coating*(= 1,000 hour salt spray)
■ Dust relief tip
Dynabolt GoldMasonry Sleeve Anchors
* Special order
Large Diameter Tapcon(LDT™)Self-Threading Anchor
(see page 68)
(see page 78)
For both Hollow and Solid Concrete Applications
59Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Hex nutTie-Wire version
FF-S-325 Group II, Type 4, Class 1Underwriters LaboratoriesFactory MutualICBO Evaluation Service, Inc. – #ER-1372City of Los Angeles – #RR2748SBCCI Compliance Report – #9570California State Fire MarshalCal TransMetro-Dade County – #01-0504.12
RM: Flanged bodyRL: Non-flanged bodyUse any bolt or threaded rod
FF-S-325 Group VIII, Type 1Underwriters LaboratoriesFactory MutualICBO Evaluation Service, Inc. – #ER-1372City of Los Angeles – #RR2748SBCCI Compliance Report – #9570California State Fire MarshalCal Trans
Fully threaded design accommodates various material thicknesses at the same embedment. One anchor length saves time and money.
Dependable,Heavy-Duty,Inspectable,Wedge Type
ExpansionAnchor
DESCRIPTION/SUGGESTED SPECIFICATIONS
Wedge Type Anchors— SPECIFIED FOR ANCHORAGE INTO CONCRETE
Wedge anchors feature a type 18-8 stainless steel split expansion ring and a threaded stud bolt body and integral cone expander, nut and washer. Anchor bodies are made of plated carbon steel, hot-dipped
galvanized carbon steel, type 304 stainless steel or type 316 stainless steelas identified in the drawings or other notations.
The exposed end of the anchor is stamped to identify anchor length.Stampings should be preserved during installation for any subsequentembedment verification.
Use carbide tipped hammer drill bits made in accordance to ANSI B212.15-1994 to install anchors.
Anchors are tested to ASTM E488 criteria and listed by ICBO and SBCCI. Anchors are listed by the followingagencies as required by the local building code: UL, FM, City of Los Angeles, California State Fire Marshal and Cal Trans.
TruboltWedgeAnchor
Fully ThreadedAdvantage
TruboltWedge Anchors
®
63Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
1. Using a bit whose diameter equals the anchordiameter, drill hole to any depth exceeding theminimum embedment. Clean hole.
2. Assemble anchor with nut and washer so that the top of the nut is flush with the top of theanchor. Drive anchor through material to be fastened so that nut and washer are flush with surface of material.
INSTALLATION STEPS
3. Expand anchor by tightening nut 3 to 5 turns, or to the specific torque requirement(see selection chart).
Trubolt Anchors
APPLICATIONS
FEATURES
Anchoring machinery and conveyors is a common wedge anchor application.The Trubolt is fully threaded to allow alarge range of embedment and fixture thickness.
Safety railings are commonly anchoredwith Trubolt wedge anchors because ofavailability in four material types for all corrosive atmospheres.
Pre-cast panels are typically anchored tothe concrete slab temporarily with Truboltwedge anchors because of reliable performance and economical pricing.
APPROVALS/LISTINGSMeets or exceeds U.S. Government G.S.A. Specification FF-S-325 Group II,Type 4, Class 1
Underwriters Laboratories
Factory Mutual
ICBO Evaluation Service, Inc. – #ER-1372(including seismic loading conditions)
Metro-Dade County – #01-0504.12
City of Los Angeles – #RR2748
SBCCI Compliance Report – #9570
California State Fire Marshal
Cal Trans
LENGTH INDICATION CODE*CODE LENGTH OF ANCHOR CODE LENGTH OF ANCHOR
Typical Applications—Structural Columns, Machinery, Equipment, etc.
Environment—Interior (non-corrosive)
Level of Corrosion—Low
Meets ASTM B633 SC1, Type III specifications for electroplating of 5um = .0002" thickness. This material is well suited for non-corrosive environments.
Typical Applications—Railings, Signage, Awnings, etc.
Meets ASTM A153 Class specifications for hot-dipped galvanizing > 45um = .002". It is highly recommended fordamp, humid environments near coastal regions. Hot-dipped galvanized Trubolts have a coating thickness of zinc that is almost 10 times as thick as electroplating. This creates greater corrosion resistance at a minimal cost.
SELECTION CHART
SELECTION CHART
Tie Wire Wedge for hanging suspended ceiling
65Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Trubolt Type 316 Stainless Steel
Contains more nickel and chromium than Type 304, and 2%-3% molybdenum, which gives it better corrosion resistance. It is especially more effective in chloride environments that tend to cause pitting.
PART THREAD ANCHOR DIA. OVERALL MAX. QTY/WT QTY/WTNUMBER LENGTH & DRILL BIT LENGTH THICKNESS PER BOX PER MASTER
In. (mm) SIZE (THREADS) In. (mm) OF MATERIAL lbs. CARTONPER INCH TO BE FASTENED lbs.
Typical Applications—Cladding, Stadium Seating, etc.
Environment—Urban (slight to moderate degree of pollution)
Level of Corrosion—Medium
Serves many applications well. It withstands rusting in architectural and food processing environmentsand resists organic chemicals, dye stuffs and many inorganic chemicals.
Typical Applications—Tunnels, Dams, Tiles, Lighting Fixtures, etc.
Environment—Marine (heavy atmosphericpollution)
Level of Corrosion—High
SELECTION CHART
SELECTION CHART
66 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
* Allowable values are based upon a 4 to 1 safety factor. Divide by 4 for allowable load values.
WS-Carbon orWS-G
Hot-DippedGalvanized
orWW-304 S.S.
or SWW-316 S.S.
WS-Carbon orWS-G
Hot-DippedGalvanized
orWW-304 S.S.
or SWW-316 S.S.
TruboltWedge Anchors
TruboltWedge Anchors
PERFORMANCE TABLE
PERFORMANCE TABLE
67Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Recommended Spacing and Edge Distance Requirementsfor Tension Loads*
ANCHOR EMBEDMENT ANCHOR EDGE DISTANCE MIN. ALLOWABLE SPACING REQUIRED MIN. ALLOWABLEDIA. DEPTH TYPE REQUIRED TO EDGE DISTANCE AT TO OBTAIN MAX. SPACING AT WHICH
In. (mm) In. (mm) OBTAIN MAX. WHICH THE LOAD WORKING LOAD THE LOAD FACTORWORKING LOAD FACTOR APPLIED = .65 In. (mm) APPLIED = .70
* Spacing and edge distances shall be divided by 0.75 when anchors are placed in structural lightweight concrete. Linear interpolation may be used for intermediate spacing and edge distances.
ANCHOR EMBEDMENT ANCHOR EDGE DISTANCE MIN. EDGE MIN. EDGE DISTANCE SPACING MIN. ALLOWABLEDIA. DEPTH TYPE REQUIRED TO DISTANCE AT WHICH AT WHICH THE REQUIRED TO SPACING BETWEEN
In. (mm) In. (mm) OBTAIN MAX. THE LOAD FACTOR LOAD FACTOR OBTAIN MAX. ANCHORS In. (mm) WORKING LOAD APPLIED = .60 APPLIED = .20 WORKING LOAD LOAD FACTOR
* Spacing and edge distances shall be divided by 0.75 when anchors are placed in structural lightweight concrete. Linear interpolation may be used for intermediate spacing and edge distances.
Combined Shear and Tension Loading—for Trubolt AnchorsAllowable loads for anchors subjected to combined shear and tension forces are determined by the following equation:
Recommended Spacing and Edge Distance Requirementsfor Shear Loads*
PERFORMANCE TABLE
PERFORMANCE TABLE
68 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Uses standard drill bits—
no special drill bits to
purchase or lose!
SAVE TIMEEASILY INSTALLED■ Installs in less than half the time of 1/2" wedge
or adhesive application■ Simply drill a pilot hole and drive the LDT anchor by
hand or impact
EASILY REMOVED■ No torching or grinding required to remove anchors
SAVE MONEYLOWER DRILL BIT COSTS■ Use standard ANSI bits instead of proprietary bits■ Single piece design, no nut and washer to assemble
USE STANDARD ANSI BITS■ No special proprietary bits to purchase or lose■ Reduce chances for anchor failure due to incorrect
bit usage
Finished head,Removable Anchor
DESCRIPTION/SUGGESTED SPECIFICATIONS
Self-threading Anchors — SPECIFIED FOR ANCHORAGE INTO CONCRETE
The LDT anchor is a high performance concrete anchor that cuts its ownthreads into concrete.
Anchor bodies are made of hardened carbon steel, plated with zinc orGRD2000® (tested to ASTM B117A for corrosion resistance).
The anchors shall have a finished hex washer head with anti-rotation serrations to prevent anchor back-out. The head of the anchor is stamped with a length identification code for easy inspection.
The anchor shall be installed with carbide tipped hammer drill bits made in accordance to ANSI B212.15-1994.
LDT Self-threadingAnchor
LargeDiameter
Tapcon (LDT ™) Anchors
LDT(3/8" and 1/2")
NOW AVAILABLE IN STAINLESS STEEL
The Easy, Fast, High Performing, RemovableTapcon, Now Available in 3/8" and 1/2" Diameter
5/8" DRILL BIT9/16" DRILL BITDRILL BIT SIZE REQUIRED
7"
HOLE DEPTH REQUIRED
1/2" LDT 5/8" wedge1/2" adhesive
7/16" DRILL BIT
4-1/2" 4-1/2"
LDT anchors specify asmaller & less expensivedrill bit than thoserequired with the 1/2"adhesive threaded rod orthe 5/8" wedge.
DIFFICULT TO REMOVE
EXPOSED THREADS
5-STEP INSTALLATION
CURE TIME
INSTALLS IN 1/2 THE TIME
EASILY REMOVED
FINISHED HEAD
PERMANENT APPLICATION
EXPOSED THREADS
DIFFICULT TO REMOVE
At 4-1/2" embedmentthe LDT anchor will giveyou performance similarto 1/2" adhesive anchorof the same depth or5/8" wedge anchors at 7" deep.
For use in concrete andconcrete block
ADVANTAGES
69Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
INSTALLATION STEPS
LDT Anchors
APPLICATIONS
FEATURES
Racking, shelving and conveyors are justa few high volume applications ideal forLarge Diameter Tapcon (LDT™). The easeand speed of installation of the LDT canreduce installation time to less than halfthe time of typical systems used today.
For installation speed, high performanceand easy removability, LDT is the anchorof choice.
APPROVALS/LISTINGS
ICBO Evaluation Service, Inc. – #ER-5890 City of Los Angeles – #RR25498
Easy InstallationInstalls into concrete by hand or impact wrench
Extra Large Hex Washer Head— With increased bearing surface — 3/8" LDT replaces 1/2" wedge
anchor application
Length Identification Head Stamp— For embedment inspection after
installation
Hi-Lo Threads— Cuts its own threads into concrete for
greater pull-out resistance
1. Using a 5/16" (for 3/8" LDT) or 7/16" (for 1/2"LDT) carbide tipped bit, drill a pilot hole at least1" deeper than anchor embedment.
2. Using a socket wrench (hand install) or electricimpact wrench, insert anchor into hole and tightenanchor until fully seated. (9/16" socket for 3/8" and3/4" socket for 1/2")
���������������
���������������
2. Installation Steps for BlockUsing a socket wrench insert anchor into hole and hand tighten anchor until fully seated.(9/16" socket for 3/8" and 3/4" socket for 1/2")
1. Using a 5/16" (for 3/8" LDT) or 7/16" (for 1/2"LDT) carbide tipped bit, drill a pilot hole at least1" deeper than anchor embedment.
���������������
Installation Steps in Concrete
Installation Steps in Concrete Block (CMU)
Installation by impact wrench—is recommendedfor faster installations or for high volume projects.Installation with impact wrench—is notrecommended for hollow block.
Installation by hand—is easy, simply using asocket wrench
LDT’s can be installed by hand or with animpact wrench
The LDT’s finished head and lack of exposedthreads virtually eliminates tire damage onfork lift trucks.
70 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
PART PART ANCHOR DRILL BIT EFFECTIVE MAX. THICKNESS QTY/WT QTY/WTNUMBER NUMBER DIA. DIA. LENGTH OF MATERIAL PER BOX PER MASTERFOR 410 FOR CARBON In. (mm) In. (mm) In. (mm) TO BE FASTENED lbs. CARTON
STAINLESS STEEL STEEL (see detail on left) In. (mm) lbs.
* The stainless steel LDT‘s will be gold in color in order to differentiate them from the carbon steel anchors which are silver.
LDT Carbon andStainless Steel
with Zinc Plating
Meets ASTM B695 specifications for zinc plating of 5um = .0002" thickness. This material iswell suited for non-corrosive environments. For greater corrosion resistance GRD2000™ coating is available as special order.
SELECTION CHART
PART DESCRIPTION USABLE OVERALL QTY/WTNUMBER DRILLING LENGTH LENGTH PER BOX
DD-5164 5/16" SDS Plus 4" 6" 1/.15
DD-7164 7/16" SDS Plus 4" 6" 1/.15
DD-71610 7/16" SDS Plus 10" 12" 1/.15
DD-124 1/2" SDS Plus 4" 6" 1/.15
DD-1210 1/2" SDS Plus 10" 12" 1/.7
DD-1216 1/2" SDS Plus 16" 18" 1/.7
DD-5164K Bulk Pack DD-5164 4" 6" 25/3.1
* Straight shank and spline shank of the appropriate size can also be used.
LDT AnchorAccessories
ACCESSORIES
SDS Carbide Bits*—stronger shaft and core than industry standard for longer bit life
LENGTH INDICATION CODE*
CODE LENGTH OF ANCHOR In. (mm)
A 1-1/2 < 2 (38.1 < 50.8)
B 2 < 2-1/2 (50.8 < 63.5)
C 2-1/2 < 3 (63.5 < 76.2)
D 3 < 3-1/2 (76.2 < 88.9)
E 3-1/4 < 4 (88.9 < 101.6)
F 4 < 4-1/2 (101.6 < 114.3)
G 4-1/2 < 5 (114.3 < 127.0)
H 5 < 5-1/2 (127.0 < 139.7)*Located on top of anchor for easy inspection.
LENGTH INDICATION CODE*
HOLE DIAMETER THROUGH FIXTURE SUGGESTED LDT DIAMETERIn. (mm) In. (mm)
7/16 (11.1) 3/8 (9.5)
1/2 (12.7) 3/8 (9.5)
9/16 (14.3) 1/2 (12.7)
5/8 (15.9) 1/2 (12.7)
DESIGN GUIDE
EffectiveLength
For proper selection of anchor diameters based upon predrilledholes through base plates and fixtures to be fastened.
71Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Allowable Tension and Shear Values* (Lbs/kN) in ConcreteCarbon and Stainless Steel1
* Allowable values are based upon a 4 to 1 safety factor. (Ultimate/4)
LDT Anchors
Recommended Edge & Spacing Requirements for Tension Loads*Carbon and Stainless Steel
ANCHOR DIA. EMBEDMENT DEPTH EDGE DISTANCE LOAD FACTOR APPLIED SPACING DISTANCE LOAD FACTOR APPLIEDIn. (mm) In. (mm) REQUIRED TO OBTAIN AT MIN. EDGE DISTANCE REQUIRED TO OBTAIN AT MIN. SPACING
MAX. WORKING LOAD 1-3/4 Inches (44mm) MAX. WORKING LOAD DISTANCE In. (mm) In. (mm) 3 Inches (76mm)
* Edge and spacing distance shall be divided by .75 when anchors are placed in structural lightweight concrete. Linear interpolation may be used for intermediate spacing and edge distances.
LDT Anchors
PERFORMANCE TABLE
PERFORMANCE TABLE
Recommended Edge & Spacing Requirements for Shear Loads*Carbon and Stainless Steel
ANCHOR DIA. EMBEDMENT DEPTH EDGE DISTANCE LOAD FACTOR APPLIED SPACING DISTANCE LOAD FACTOR APPLIEDIn. (mm) In. (mm) REQUIRED TO OBTAIN AT MIN. EDGE DISTANCE REQUIRED TO OBTAIN AT MIN. SPACING
MAX. WORKING LOAD 1-3/4 Inches (44mm) MAX. WORKING LOAD DISTANCE In. (mm) In. (mm) 3 Inches (76mm)
3/8 (9.5) 1-1/2 (38.1) 3 (76.2) 25% 6 (152.4) 57%
2 (50.8) 4 (101.6) 25% 6 (152.4) 57%
2-1/2 (63.5) 5 (127.0) 25% 6 (152.4) 57%
3-1/2 (88.9) 5 (127.0) 25% 6 (152.4) 57%
1/2 (12.7) 2 (50.8) 5 (127.0) 25% 8 (203.2) 60%
3-1/2 (88.9) 5 (127.0) 25% 8 (203.2) 60%
4-1/2 (114.3) 5-1/2 (139.7) 25% 8 (203.2) 60%
* Edge and spacing distances shall be divided by .75 when anchors are placed in structural lightweight concrete. Linear interpolation may be used for intermediate spacing and edge distances.
LDT Anchors
PERFORMANCE TABLE
72 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Allowable Tension and Shear* (Lbs/kN) in Concrete Block (anchors should be installed by hand in hollow block)
73Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Multi-Set IIDrop-In Anchors
ADVANTAGES
■ Lipped anchor body keeps anchor flush
■ Easy installation
■ Keeps all rods same length
■ Easy inspection
■ Available in carbon steel, 18-8 and 316 stainless steel
InternallyThreaded Heavy-
Duty AnchoringSystems
DESCRIPTION/SUGGESTED SPECIFICATIONS
Drop-In, Shell-Type Anchors— SPECIFIED FOR ANCHORAGE INTO CONCRETE
Drop-In, shell-type anchors feature an internally threaded, all-steel shell with expansion cone insert and flushembedment lip. Anchors are manufactured from plated carbon steel, 18-8 stainless steel and 316 stainless steel.
Anchors should be installed with carbide tipped hammer drill bits made in accordance to ANSI B212.15-1994 specifications.
Anchors should be tested to ASTM E488 criteria and listed by ICBO and SBCCI. Anchors should also be listed by the following agencies as required by the local building code: UL, FM, City of Los Angeles, Metro-Dade County,California State Fire Marshal and Cal Trans.Multi-Set II Drop-In Anchors
RM Drop-In Anchor
■ Below surface setting for easy patch work
■ Higher performance potential with deep embedment setting
RL Drop-In Anchor
■ Optimized (only 3/4" long) for use in hollow-core, pre-cast plank and post-tension slabs
■ Lip keeps anchor flush during installation
■ Shallow drilling—fast installation
RX-38 Drop-In Anchor
■ Quick thread attachment—ideal for 1 sided forming
■ Use coil rod on job
■ 2 diameters (1/2" and 3/4")
formwork
existingconcrete
coil rod, holding form in place
bentrebar
Coil Thread Anchor
®
74 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
1. Drill hole the same diameter as outside diameterof anchor being used to any depth exceeding minimum embedment. Clean hole.
2. Drive anchor flush with surface of concrete.
3. Expand anchor with setting tool provided.
Anchor is properly expanded when shoulder
of setting tool is flush with top of anchor.
To set anchor below surface:
Drill hole deeper than anchor length. Thread bolt into anchor. Hammer anchor into hole until bolt head is at desired depth. Remove bolt and set anchor with setting tool.
To set anchor flush with surface:
INSTALLATION STEPS
Multi-Set II Anchors
APPLICATIONS
FEATURES
Pumps and heavy piping are commonapplications for larger diameter Multi-Set Drop-In Anchors.
Cable tray and strut suspended fromconcrete ceilings are ideal Multi-Setapplications. In post-tension or hollow-core slabs use the RX-38.
The Multi-Set Anchor is the standardfor pipe-hanging. The RM version has aretainer lip to keep all anchors flush atthe surface, keeping all your threadedrod the same length.
APPROVALS/LISTINGSMeets or exceeds U.S. Government G.S.A. Specification FF-S-325 Group VIII, Type 1
Underwriters Laboratories
Factory Mutual
ICBO Evaluation Service, Inc. – #ER-1372
City of Los Angeles – #RR2748
SBCCI Compliance Report – #9570
California State Fire Marshal
Cal Trans
Expander Slots—allow for easy settingand superior performance
Cone Insert—that expands the anchorwhen driven with setting tool and hammer
Body—available in zinc-plated steel, 18-8 stainless steel, and 316 stainless steel
Easy Depth Inspection—keeps threadedrod drop lengths consistent
Retainer Lip—to keep anchor flush with surface
(See page 75 for part numbers.)
PART NUMBER RT-138
1 setting tool per master carton—except for RX-38 which is 1 per box.
PART NUMBER RTX-138
For use with RX-38 only.
For use with threaded rods or headedbolts (supplied by contractor)
75Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
USER APPLICATION BASE CORROSION DROP-IN PART SETTING BOLT SIZE- DRILL BIT THREAD EMBEDMENT QTY/WT QTY/WTTYPE MATERIAL RESISTANCE ANCHOR NUMBER TOOL THREADS SIZE DEPTH MIN. HOLE PER BOX PER
LEVEL TYPE PART PER INCH In. (mm) In. (mm) DEPTH lbs. MASTER CTN NUMBER* In. (mm) lbs.
* Allowable values are based upon a 4 to 1 safety factor. Divide by 4 for allowable load values.
RM, RLor CL-Carbon or
SRM-18-8 S.S. or SSRM-316 S.S.
Multi-Set IIDrop-In Anchors
Combined Shear and Tension Loading—for Multi-Set AnchorsAllowable loads for anchors subjected to combined shear and tension forces are determined by the following equation:
* Spacing and edge distances shall be divided by 0.75 when anchors are placed in structural lightweight concrete. Linear interpolation may be used for intermediate spacing and edge distances.
RM, RL or CL-Carbon
or SRM-18-8 S.S. or
SSRM-316 S.S.
Multi-Set IIDrop-In Anchors Recommended Spacing and Edge Distance Requirements*
* The tabulated values are for RX-38 anchors installed at a minimum of 12 diameters on center and minimum edge distance of 6 diameters for 100 percent anchor efficiency. Spacing and edge distance may be reduced to 6 diameters spacing and 3 diameter edge
distance provided the values are reduced 50 percent. Linear Interpolation may be used for intermediate spacings and edge margins.
* Allowable values are based upon a 4 to 1 safety factor. Divide by 4 for allowable load values.
Ultimate Shear and Tension Values (Lbs/kN) for RX-38(3/4" Embedment)*
■ Carbon Steel anchors feature a special organicclear coat that achieves 250 hours, neutral saltspray test.
■ Stainless Steel anchors available in 316 SS as astandard product.
■ Finished head anchors, bolt can be easilyremoved.
Unique Design ofHeavy Duty,
Finished HeadAnchor, Clamps
Down Base Plates
Dynabolt Gold Heavy-DutySleeve Anchor
The Dynabolt Gold anchor is a heavy duty sleeve anchor that can be used toanchor fixtures to concrete, concrete block, or brick. The anchor consists of ahex head bolt, a spacer sleeve, specially designed expansion sleeve, and anexpansion cone. Carbon steel anchors feature a Grade 5 hex head bolt anda special organic clear coat over zinc plating for added corrosion protection(250 hours, neutral salt spray, ASTM B117). Stainless steel anchors areavailable in Type 316 Stainless Steel.
DESCRIPTION/SUGGESTED SPECIFICATIONS
Heavy-Duty Sleeve Type Anchors — SPECIFIED FOR ANCHORAGE INTO CONCRETE, MASONRY, GROUT-FILLED BLOCK ANDHOLLOW BLOCK
Dynabolt Gold(Carbon Steel)
Dynabolt Gold (316 Stainless Steel)
The chart shows how much eachanchor shortens or “pulls down”when the anchors are torqued.The vertical axis is the distancein inches.
0.3
0.25
0.2
0.15
0.1
0.05
03/8" 1/2" 5/8" 3/4"
Anchor Diameter
Pull D
own D
istan
ce
Upon tightening, the Dynabolt Gold pulls down and shortens in length.This dynamic action creates tremendous holding power while at thesame time pulling down uneven base plates.
The unique design of Dynabolt Gold—it twists, shortens and pulls down.
79Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
1. Use a bit with a diameter equal to the anchor.See selection chart to determine proper sizebit for anchor used. Drill hole to any depthexceeding minimum embedment. Clean hole.
2. Insert assembled anchor into hole, so thatwasher or head is flush with materials to be fastened.
INSTALLATION STEPS
3. Expand anchor by tightening nut or head2 to 3 turns.
Dynabolt Gold Anchors
APPLICATIONS
FEATURES
Dynabolt Gold is ideal for attachinglumber to concrete, concrete block,or brick.
Dynabolt Gold offers excellent holdingstrength for attaching steel ledgers.
The Dynabolt Gold has a finished head and tremendous performance in grouted block or solid concrete for a clean, safe stair rail installation.
APPROVALS/LISTINGS
Meets or exceeds U.S. Government G.S.A. Specification FF-S-325 Group II,Type 3, Class 1
Other approvals pending
Finished Head Bolt, Easy to remove
Grade 5 Bolt – Carbon steel anchors
AISI 316 – Stainless steel anchors
Special slotted expansion sleeve – twistsand shortens to provide maximumclamping force when anchor is torqued
Threaded expansion cone for maximumexpansion force inside the sleeve
80 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
PERFORMANCE TABLE
ANCHOR INSTALLATION EDGE DISTANCE MIN. ALLOWABLE SPACING REQUIRED MIN. ALLOWABLE DIA. TORQUE REQUIRED TO OBTAIN EDGE DISTANCE AT TO OBTAIN MAX. SPACING BETWEEN ANCHORS
In. (mm) Ft. Lbs. (Nm) MAX. WORKING LOAD WHICH THE LOAD FACTOR WORKING LOAD LOAD FACTORIn. (mm) APPLIED = 0.75 In. (mm) APPLIED = 0.50
81Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
PERFORMANCE TABLE
PERFORMANCE TABLE
ANCHOR INSTALLATION EDGE DISTANCE MIN. ALLOWABLE SPACING REQUIRED MIN. ALLOWABLE DIA. TORQUE REQUIRED TO OBTAIN EDGE DISTANCE AT TO OBTAIN MAX. SPACING BETWEEN ANCHORS
In. (mm) Ft. Lbs. (Nm) MAX. WORKING LOAD WHICH THE LOAD FACTOR WORKING LOAD LOAD FACTORIn. (mm) APPLIED = 0.50 In. (mm) APPLIED = 0.50
* Allowable values are based upon a 4 to 1 safety factor. Divide by 4 for allowable load values. The tabulated values are for anchors installed in a minimum of 12 diameters on center and a minimum edge distance of 6 diameters for 100 percent anchor efficiency. Spacing and edge distance may be reduced to 6 diameter spacing and 3 diameter edge distance, provided the values are reduced 50 percent. Linear interpolation may be used for intermediate spacings and edge distances.
Ultimate Shear and Tension Values in Masonry Units (Lbs/kN)*
PERFORMANCE TABLE
Dynabolt GoldSleeve Anchors
82 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
DynaboltSleeve
Anchors
ADVANTAGES
■ Anchor diameter equals hole diameter
■ Available in hex head and six other head styles
■ Available 1/4 - 3/4" diameter up to 6-1/4" length
■ Zinc plated carbon steel and 304 stainless steel
■ Provides full 360° hole contact over large areaand reduces concrete stress
■ Heavy-loading capacity
■ Preassembled for faster, easier installations
■ Dynabolt can be installed through object to be fastened
■ Sleeve design improves holding power
■ No pre-spotting of holes necessary
Versatile,Medium-DutySleeve Anchor
Available Head Styles
Sleeve type anchors feature a split expansion sleeve over a threaded studbolt body and integral expander, nut and washer.
Anchors are made of Plated Carbon Steel, or Type 18-8 Stainless Steel.
Anchors should be installed with carbide tipped hammer drill bits made inaccordance to ANSI B212.15-1994.
Anchors are tested to ASTM E488 criteria.
DESCRIPTION/SUGGESTED SPECIFICATIONS
Sleeve Type Anchors— SPECIFIED FOR ANCHORAGE INTO CONCRETE, MASONRY, GROUT-FILLED BLOCK ANDHOLLOW BLOCK
Phillips Flat Head Hex Nut Acorn Nut(FS) (HN) (AN)
Tie Wire Round Head Threshold Flat Head(TW) (RS) (TH)
DynaboltMasonrySleeve Anchor
Full range of head style, corrosion protection, and sizes makes theDynabolt Sleeve the right product for almost any application.
Dynabolt Hex Nut Sleeve Anchor
®
83Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
1. Use a bit with a diameter equal to the anchor.See selection chart to determine proper sizebit for anchor used. Drill hole to any depthexceeding minimum embedment. Clean hole.
2. Insert assembled anchor into hole, so thatwasher or head is flush with materials to be fastened.
INSTALLATION STEPS
3. Expand anchor by tightening nut or head2 to 3 turns.
Dynabolt Anchors
APPLICATIONS
FEATURES
Electrical junction boxes are commonapplications for the Dynabolt Sleeveanchor because it works well in solidconcrete, concrete block, and brick. It is also available in several finishedhead styles.
The Dynabolt Sleeve anchor works well in hollow materials like brick andblock. It is available in zinc-plated carbon steel and 304 stainless steel.
Door and window frames are commonlyattached to the structure with DynaboltSleeve anchors because of their finishedand threshold head styles and performance in block and brick.
APPROVALS/LISTINGS
Meets or exceeds U.S. Government G.S.A. Specification FF-S-325 Group II,Type 3, Class 3
Factory Mutual
SBCCI Compliance Report – #9570
California State Fire Marshal
Multiple Head Styles—for any application
Range of Fixture Thickness—no weakened shear area because of all-steel spacer sleeve (no plastic)
Sleeve Design—for better holding
360° Hole Contact—gives better pullout resistance
84 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
DynaboltCarbon Steel with Zinc Plating
PART ANCHOR EFFECTIVE BOLT MIN. MAX. QTY/WT QTY/WTNUMBER DIA. & ANCHOR DIA./ EMBEDMENT THICKNESS PER BOX PER
DRILL LENGTH* THREADS In. (mm) OF MATERIAL lbs. MASTERBIT SIZE In. (mm) PER INCH TO BE FASTENED CARTON
3/4 (19.1) 90 (122.0) 5/8 (15.9) 2-1/2 (63.5) Carbon -- -- -- -- 4,200 (18.7) 10,200 (45.4) -- -- -- -- 4,200 (18.7) 10,200 (45.4)* Allowable values are based upon a 4 to 1 safety factor. Divide by 4 for allowable load values. The tabulated values are for anchors installed in a minimum of 12 diameters on center and a minimum edge distance of 6 diameters for 100 percent
anchor efficiency. Spacing and edge distance may be reduced to 6 diameter spacing and 3 diameter edge distance, provided the values are reduced 50 percent. Linear interpolation may be used for intermediate spacings and edge distances.
Ultimate Shear and Tension Values in Masonry Units (Lbs/kN)*
PERFORMANCE TABLE
PERFORMANCE TABLE
PERFORMANCE TABLE
DynaboltSleeve Anchors
Combined Shear and Tension Loading—for Dynabolt AnchorsAllowable loads for anchors subjected to combined shear and tension forces are determined by the following equation: (Ps /Pt ) + (Vs /Vt ) ≤ 1
Stud Type Anchors — SPECIFIED FOR ANCHORAGE INTO CONCRETE
Stud Anchors feature a bolt body and pre-assembled expander plug.Anchors should be installed with carbide tipped hammer drill bits made in accordance to ANSI B212.15-1994.
Anchors are tested to ASTM E488 criteria and listed by SBCCI. Anchors are listed by the following agencies as required: UL and FM.
APPLICATIONS
Stud Anchors are commonly used to anchorequipment to concrete slabs. The externalstuds make for easy jacking and leveling for easy cleanup in industrial settings.
APPROVALS/LISTINGS
Meets or exceeds U.S. Government G.S.A. specification FF-S-325 Group VIII, Type 2
SBCCI Compliance Report – #9570 Factory Mutual
California State Fire Marshal Underwriters Laboratories
™
StudAnchor
87Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
PART HOLE OR BIT SIZE OVERALL STUD THREAD MIN. QTY/WT QTY/WTNUMBER (THREADS) LENGTH LENGTH LENGTH EMBEDMENT PER BOX PER MASTER
PER INCH In. (mm) In. (mm) In. (mm) In. (mm) lbs. CARTON lbs.
* Linear interpolation may be used for intermediate spacing and edge distances.
Stud Anchors Recommended Spacing and Edge Distance Requirements*
Combined Shear and Tension Loading—for Stud AnchorsAllowable loads for anchors subjected to combined shear and tension forces are determined by the following equation: (Ps /Pt ) 5/3 + (Vs /Vt ) 5/3 ≤ 1
Note: Recommended thickness of concrete for bottom-bearing anchors = embedment depth+ three times anchor diameter
Redi-DriveAnchors
®
100% ContactMore contact—more holdingpower!
.215 Shank Diameter
.198
ADVANTAGES■ High performance provides superior holding
values in concrete and other masonry materials
■ Fire resistant
■ Tamper resistant
■ Standard 3/16" drill hole size—cheaper bitand faster installation
■ Available in 3/4", 1-1/8", 1-5/8", 2", 2-1/2", and3" lengths
■ Most economical steel anchor available
■ Provides fast, high performance drive-type fastening without torquing or need for special setting equipment
As simple as using a nail—drive into predrilled holes for tremendous holdingstrength in concrete. Compressive strength is created by forcing a larger
diameter fastener into a smaller size hole.The greater the degree of contact the greater the holding power.
Only 3 Points of ContactHalf the holding power of Redi-Drive
.190ShankDiameter
.260
Only 2 Points of ContactOne-fourth theholding powerof Redi-Drive
.250ShankDiameter
.260
The Redi-Drive is a high performance small diameter one-piece hammer-drive anchor. The anchor holds based on a friction principle—the shank diameter is larger than the drill hole size. Anchors shall be
installed with carbide-tipped hammer drill bits made in accordance to ANSI B212.15-1994.
The Redi-Drive is available in four types…mushroom head, pipe-hanging (1/4" & 3/8") FM approved (on 3/8"), Tie-Wire, and double-head forming versions. Anchor performance in solid concrete at one inch embedment shallexceed 400 lbs. allowable tension load and 750 lbs. allowable shear load.
DESCRIPTION/SUGGESTED SPECIFICATIONS
Light-Duty Hammer-Drive Masonry Anchors—SPECIFIED FOR ANCHORAGE INTO CONCRETE, BLOCK AND BRICK
Redi-Drive HighPerformanceHammer-DriveAnchor
88 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Redi-DriveAnchors—High
PerformanceWithout Torquing
TieWire
FinishedHead
PipeDrive
FormingAnchor
89Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
1. Drill a 3/16" diameter hole (1/4" for 3/8" pipedrive) at a minimum depth (see chart) andclean hole.
2. Insert anchor through material to be fastened(insert tie-wire or pipe version Redi-Drive Anchorsinto drilled holes) and drive anchor with a 3-lb.hammer until the head is flush with surface ordesired embedment.
��
��
����yy
���yyy
�������y
���yyy
��������yy
���yyy
INSTALLATION STEPS
3. Anchor is now set.
1. Drill 3/16" diameter hole in concrete.
2. Hammer in flat side of Redi-Drive 1-1/4".
����
����
����
INSTALLATION STEPS FOR REDI-TIE-DRIVE
3. The Redi-Drive is set. Tie acoustical or electricaldrop wire to open hole.
Redi-Drive Anchors
FEATURES
APPROVALS/LISTINGS
Meets or exceeds U.S. Government G.S.A. Specification FF-S-325 Group VI
Factory Mutual (3/8" pipe-drive)
Tamper-Proof—mushroom head
100% Hole Contact—.215 shank in .198 hole
Dog-Point—for easy insertion and installation
APPLICATIONS
Signage and other light duty metalproducts are common applications for the Redi-Drive. It has superior performance in block, brick and solidconcrete, and is tamper-proof.
Wood attachments to concrete arecommon Redi-Drive applications,whether permanent or temporary.
Electrical boxes and conduit clips that need permanent attachment areideal applications for the Redi-Drive.It works well in all base materialsand is fast and economical.
90 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Typical Applications—Electrical boxes, conduitclips, and duct work
Redi-DriveAnchors
PART HEAD DIA. DRILL SIZE TOTAL MIN. MAX. FIXTURE CLEARANCE QTY/WT QTY/WT PERNUMBER In. (mm) In. (mm) LENGTH EMBEDMENT THICKNESS HOLE SIZE PER BX MASTER CARTON
Safe working loads for single installations under static loading conditions should not exceed 25% of the ultimate capacity.
Redi-DriveAnchors
The Redi-Drive is the mostversatile of all of theseproducts. It can be used at all these embedmentdepths and is superior inpull-out performance tothese competitive anchors.
PERFORMANCE TABLE
PERFORMANCE TABLE
*Rawl Spike ® cannot be installed in 3/4” embedment
Rawl Spike ® is a registered trademark of Powers Fastening, Inc.
Embedment in 4500 psi Concrete
PART DESCRIPTION QTY/WT QTY/WTNUMBER PER BOX PER MASTER
CARTON
RDST Redi-Drive Setting Tool 1/1 1/1
Redi-Drive Setting Tool
ACCESSORIESInstalls Redi-Drive anchors in tight and hard to access areas—easily and quickly. Just place anchor in rubber“holding cap,” place against work surface and hammer in anchors.
Hex Head style on Tapcon Anchors is availablefor majority of fixture anchoring needs
Climaseal™ Coating is standard on all Tapconanchors to provide extended corrosion resistance
Now available in 410 Stainless Steel
Phillips Flat Head style is available when flushseating is necessary in countersink applications
Hi-Lo Threads with notches cut into masonrymaterials for greater stability and pullout values
Lengths of Tapcon Anchors range from 1-1/4" to 4" in 3/16" and up to 6" in 1/4" diameters.The tapered shank provides a wedging action for a strong reliable hold
Nail-Type Point guides the anchor into the pre-drilled hole. Excellent for wood to concrete applications
The “original masonry” anchor that cuts its own threads into concrete, brick,or block. Maximum performance is achieved because the Tapcon Anchor,the Condrive Installation Tool, and the carbide-tipped Tapcon Drill Bits aredesigned to work as a system. It is essential to use the Condrive tool and thecorrect drill bit to assure consistent anchor performance.
DESCRIPTION/SUGGESTED SPECIFICATIONS
Tapcon Anchors —SPECIFIED FOR ANCHORAGE INTO CONCRETE, BRICK OR BLOCK®
93Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
1. With sleeve off and drill bit exposed, drill pilothole 1/4" deeper than recommended anchorembedment. Snap proper anchor socket ontoend of sleeve. Slide drive sleeve over drill bit.
2. Insert head of Tapcon anchor into hex or phillips socket.
INSTALLATION STEPS
3. Put point of anchor into pre-drilled hole anddrive until anchor is fully seated.
Tapcon Anchors
APPROVALS/LISTINGS
ICBO Evaluation Service, Inc. – #ER-3370 (Carbon Steel only)
Metro-Dade County – #00-0118.02
City of Los Angeles – #RR24953
Fixture Thickness—determine the fixture thickness to be anchored
Anchor Embedment—with a minimum recommended embedment of 1", the correctTapcon anchor choice can be made. Holedepth must be a minimum 1/4" deeperthan the anchor embedment to allow fordisplaced material
Hole Diameter—proper hole diameter is very important to insure consistent performance and maximum pulloutstrength. 3/16" anchors require 5/32"diameter bits, and 1/4" anchors require3/16" diameter bits
APPLICATIONS
Tapcon is especially well suited forwindow and door frames because itperforms well in block, is available ina flat head style, and is fast to install.
Many horizontal or “wall” applicationsare attached with Tapcon because it isremovable and works well in block and brick.
The picture shows the Condrive 1000Installation Kit in action. The kit makesfor fast and easy change over from drillbit to driver and controls the drivingtorque to prevent thread stripping andhead snapping in hard base materials.
FEATURES
Head Styles
3/16" Diameter: 1/4" slotted hex washer head (HWH)1/4" Diameter: 5/16" slotted hex washer head (HWH)
3/16" Diameter: #2 phillips flat head (PFH)1/4" Diameter: #3 phillips flat head (PFH)
94 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
PART NO. PART NO. PART NO. PART NO. RECOMMENDED FIXTURE BIT BITS FOR BITS FOR BITS FOR BITS FOR3/16" 1/4" 3/16" 1/4" TAPCON LENGTH THICKNESS LENGTH 3/16" TAPCON 1/4" TAPCON 3/16" SDS 1/4" SDS
HEX HEAD HEX HEAD FLAT HEAD FLAT HEAD In. (mm) INCHES In. (mm) PART NO. PART NO. BIT NO. BIT NO.
All boxes of ITW Tapcon come packaged with matching carbide-tipped bit. Tapcon is packaged 100 pieces per box and 500 pieces per master carton except HW4-600 and PF4-600 (400 in master carton).
TapconAnchors
SELECTION CHART
PART NO. PART NO. RECOMMENDED FIXTURE BIT DRILL BIT1/4" 1/4" TAPCON LENGTH THICKNESS LENGTH PART NO.
Safe working loads for single installation under static loading should not exceed 25% of the ultimate load capacity.The tabulated values are for anchors installed in a minimum of 12 diameters on center and a minimum edge distance of 10 diameters for 100 percent anchor efficiency.
Ultimate Shear and Tension Values (Lbs/kN) in ConcreteTapcon
Anchors
ANCHOR DEPTH OF EMBEDMENT IN SOLID MATERIAL In. (mm)DIA. 1" (25.4) 1-1/4" (31.8) 1-1/2" (38.1) 1-3/4" (44.5)
(Note: 1 matching bit is included in each box of Tapcon anchors. For part numbers see selection chart on page 94 and carbide bits on page 107.)
Condrive 1000Spare Parts
ADVANTAGES■ Fast change from drilling to driving
■ Eliminates need to change out chucks and bits
■ Eliminates need for two tools
■ Special nut driver is recessed for torque controlto reduce head breakage
■ Includes bits for all sizes hex and phillips head
The key to Tapcon’s fast and easy installation is the multi-purpose CondriveInstallation Tool. The drive sleeve, along with the hex head and phillipssockets provide the installer with the flexibility necessary for the completevariety of Tapcon applications.
DESCRIPTION/SUGGESTED SPECIFICATIONS
Condrive 1000 Installation Tool—SPECIFIED FOR ANCHORAGE INTO CONCRETE, BRICK OR BLOCK
APPLICATIONS
The picture shows the Condrive 1000 InstallationKit in action. The kit makes for fast and easychange over from drill bit to driver and controlsthe driving torque to prevent thread strippingand head snapping in hard base materials.
Part No. C1000
(Does not include drill bit)
(D)
(E) (C)
(B)(A)
97Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
E-ZAncor
ADVANTAGES
■ Fast—no pre-drilling
■ Easy—just use #2 phillips bit
■ Clean and neat—tri-cut point drills a small hole and seats flush
■ Corrosion resistance
■ Removable—easily backed out of wallboard
■ Breakaway point for easy usage when cavityis shallow
The Original Self-Drilling
Drywall Anchor
APPLICATIONS■ Electrical fixtures
■ HVAC fixtures
■ Bathroom accessories
■ Shelving
■ Closet organizers
■ Curtain rods
■ Signage
The E-Z Ancor is a one-piece self-drilling anchor designed for optimalholding performance in gypsum wallboard. Available in zinc or highstrength engineered plastic (non-conductive). Ideal anchor for 3/8",1/2" and 5/8" gypsum wallboard.
DESCRIPTION/SUGGESTED SPECIFICATIONS
E-Z Ancor Self-Drilling Drywall Anchors— SPECIFIED FOR ANCHORAGE INTO GYPSUM WALLBOARD
1. Place #2 phillips screwdriveror cordless screwdriver (#2 phillips bit) into recess of E-Z Ancor.
2. Press into Gypsum wallboardwhile turning the anchorclockwise until seated flush.
INSTALLATION STEPS3. Place fixture in position over
installed E-Z Ancor. Insert screw (#8A or AB screws are recommended). Tighten fixture into place.
SELECTION CHART
PERFORMANCE TABLE
99Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Hammer-SetAnchors
ADVANTAGES
■ Fast, easy installation
■ Works in concrete, block and brick
■ Install through material to be fastened
■ Low profile mushroom head style
Nail-DriveAnchors
DESCRIPTION/SUGGESTED SPECIFICATIONS
Hammer-Set Nail Drive Anchors— SPECIFIED FOR ANCHORAGE INTO CONCRETE, BLOCK OR BRICK
APPLICATIONSNOT FOR USE IN OVERHEAD APPLICATIONS*
■ Electrical boxes
■ Conduit clips
■ Drywall track
■ Roof flashing* For overhead applications refer to page 88 for Redi-Drive information and performance data
1. Drill hole through material to be fastened into base material.(See selection chart for drill size).
2. Insert Hammer-Set into hole untilhead of anchor body is flush withmaterial to be fastened. Tap the nailuntil flush with head of anchor.
� ��INSTALLATION STEPS
3. Anchor is now set.
APPROVALS/LISTINGS
Meets or exceeds GSA specification FF-S-325 Group V, Type 2, Class 3
The Hammer-Set one-piece zinc plated steel anchor consists of anexpansion body and expander drive pin. Anchors meet or exceed GSAspecification FF-S-325 Group V, Type 2, Class 3.
™
Hammer-SetNail-DriveAnchor
100 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
PART DESCRIPTION DRILL MAX. FIXTURE MIN. MIN. QTY/WT QTY/WTNUMBER In. (mm) SIZE THICKNESS EMBEDMENT HOLE SIZE PER BOX PER MASTER
In. (mm) In. (mm) In. (mm) In. (mm) lbs. CTN-lbs.
HS-1607 3/16 x 7/8 (4.8 x 22.2) 3/16 (4.8) 1/4 (6.4) 5/8 (15.9) 1-1/8 (28.6) 100/ 2.0 1000/ 20
HS-1406 1/4 x 3/4 (6.4 x 19.1) 1/4 (6.4) 1/8 (3.2) 5/8 (15.9) 1 (25.4) 100/ 2.2 1000/ 22
HS-1410 1/4 x 1 (6.4 x 25.4) 1/4 (6.4) 1/4 (6.4) 3/4 (19.1) 1-1/4 (31.8) 100/ 2.4 1000/ 24
HS-1412 1/4 x 1-1/4 (6.4 x 31.8) 1/4 (6.4) 1/2 (12.7) 3/4 (19.1) 1-1/2 (38.1) 100/ 2.6 1000/ 26
HS-1414 1/4 x 1-1/2 (6.4 x 38.1) 1/4 (6.4) 3/4 (19.1) 3/4 (19.1) 1-3/4 (44.5) 100/ 2.8 1000/ 28
HS-1420 1/4 x 2 (6.4 x 50.8) 1/4 (6.4) 1-1/4 (31.8) 3/4 (19.1) 2-1/4 (57.2) 100/ 3.5 1000/ 35
Hammer-SetSELECTION CHART
Hammer-Set Anchors
ANCHOR EMBEDMENT 4000 PSI (27.6 MPa)DIA. In. (mm) TENSION SHEAR
In. (mm) Lbs. (kN) Lbs. (kN)
3/16" (4.8) 5/8" (15.9) 640 (2.8) 810 (3.6)
1/4" (6.4) 3/4" (19.1) 935 (4.2) 1,506 (6.7)
1/4" (6.4) 1" (25.4) 1,414 (6.3) 1,506 (6.7)
1/4" (6.4) 1-1/4" (31.8) 1,755 (7.8) 1,506 (6.7)
Safe working loads for single installations under static loading conditions should not exceed 25% of the ultimate capacity.
Hammer-Set
PERFORMANCE TABLE
Bulk Packaging Available
Ultimate Shear and Tension Valuesin Concrete (Lbs/kN)*
101Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Nylon DriveAnchors
Fast Installation,Removable Anchor for
All Types of Masonry
ADHESIVE ANCHORING SYSTEMSADHESIVE ANCHORING SYSTEMS
ADVANTAGES■ Easy to install through part to be fastened
■ Expands by hammering on screw (or drive with a screw gun)
■ Made from Polyamide 6.6 (highly durable nylon)
■ Easy to remove—back out screw
INSTALLATION STEPS
PART ANCHOR ANCHOR BIT SIZE QTY/WT QTY/WT PERNUMBER DIAMETER LENGTH In (mm) PER BOX MASTER CTN
Whatever your concrete anchoring needs, ITW Ramset/Red Head has the high-performance carbide drill bitsyou’ll need. From SDS Plus and A-Taper to Straight Shank carbide bits, you’re assured of 100% performancesatisfaction.
All carbide bits are designed and manufactured with features that produce anywhere from a 25% to a 50%longer bit life. That means your bits go further...so youcan go further and be more productive on the job.
Features include vacuum heat treating, special designflutes and vacuum brazing. And all bits are manufacturedfrom high grade carbide and cobalt for longer bit life.
Included in this section is a handy cross reference chartallowing you to utilize Red Head carbide bits for superiorperformance in all your concrete anchoring systems.
Carbide Bits
100% guaranteed performancemeans you’ll drill more holes,cleaner holes and do it faster…saving you time and money.
104 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Carbide Bits
ADVANTAGES
Carbide Drill Bits for Concrete
Anchoring Systems
DESCRIPTION
Carbide Bits — Anyone can make a carbide bit. It takes a dedicated and confident manufacturer to stand behind their carbide bits with a 100% SatisfactionGuarantee. Not just a guarantee on the quality of the bit, but a 100%Satisfaction Guarantee on the performance of that bit. Take a look at someof the quality built into every bit from Ramset/Red Head.
This quality is built into every bit to give you a performance edge.Ramset/Red Head carbide bits will perform better because of the integrity of the raw materials used and the quality of the manufacturing process. You’ll drill more holes, cleaner holes, and do it faster. That saves you time and money on the job.
ITW Ramset/Red Head guarantees the performance of every bit in their carbide line. This is not just the standard guarantee for warranty against manufacturing defects on the bit. This guarantee includes the PERFORMANCE of that bit...to your 100% satisfaction.
ITW Ramset/Red Head guarantees:
■ Labor savings due to faster drilling ■ Cleaner holes
■ Less vibration and noise ■ Longer bit life and more accurate holes per bit
If you do not agree that your Ramset/Red Head bit performs better than the brand you currently use, we willfully return the price of your purchase or replace the bit.
WHY YOU SHOULD BUY YOUR BITS FROM ITW RAMSET/RED HEAD
ITW Ramset/Red Head has over 75 years of experience, manufacturing and supplying the highest-qualityanchors, chemical anchoring systems, and related drilling products to the construction market. With that typeof background, we know the anchoring market. And we know what it takes to drill, secure and anchor in the toughest substrates. Our expertise in anchoring has led us to deliver the highest quality carbide bits toensure optimum anchoring performance.
From manufacturing chemical epoxy systems, to making almost every conceivable type of anchor for solid concrete, hollow block and brick applications, we have built a reputation for first class products, service and support.
We know what it takes to make a quality bit. We know the steel, the fluting, the carbide tip, the brazing process. And we don’t takeany shortcuts. Rest assured that you can depend on the performance
of Ramset/Red Head carbide bits. We guarantee it.
Ramset/Red HeadCarbide Bits—Every Bit Better
105Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Carbide Bits
FEATURES APPROVALS/LISTINGS
Made to ANSI standardsHL Carbide and Cobalt—Higher density carbideand even distribution of cobalt means your bits staysharper longer for smoother, rounder holes
Special Design Flutes—Special undercut flutingmeans quick and complete dust removal. Cleaner holes mean better anchoring
Vacuum Heat Treating—Evenly tempered andannealed to increase the steel’s strength by 25% at the core for longer bit life
Shot Peening—A “skin-hardening” compressionprocess creates high torque strength and reducesflute wear for longer life
Vacuum Brazing—Solid braze of copper on both the sides and the bottom of the tip, applied in a vacuum oven at 1900° F ensures that the bit tips nevercome out
Multi-Cutter Head Styles—Unique multi-cutterhead for faster dust evacuation allows you to drill 20%faster than standard carbide heads. Two additional cutting tips reduce vibration 60% and increase bit life
Bosch® — Robert Bosch Power Tool Corp.DeWalt® —DEWALT Industrial Tool CompanyHilti® — Hilti of America, Inc.Hitachi® — Hitachi Power Tools U.S.A., Ltd.Kango® — Kango Wolf Power Tools, Inc.
SDS Max Facts■ Vacuum heat-treated tool steel at core is
25% stronger
■ Vacuum-brazed with pure copper at 1900˚Ffor superior braze and longer bit life
■ Vario flutes with progressive angles forstraighter holes and faster dust removal
■ Made to ANSI standards
Multi-Cutter Head■ Improves bit life by more than 50%
■ Reduces vibration up to 60%
■ Reduces noise up to 30%
■ Extends hammer life
* All bits 1/2" thru 9/16" are single tip carbide; all others are multi-cutter.
SELECTION CHART
Tapcon SDS BitsPART DESCRIPTION
NUMBER
790059 7” (SDS Rotohammer Bits for use with 3/16”Tapcon)7901060 5” (SDS Rotohammer Bits for use with 1/4”Tapcon)7901059 7” (SDS Rotohammer Bits for use with 1/4”Tapcon)
SDS Bits specially designed for use with Condrive 1000 driver tool.
SELECTION CHART
108 Call our toll free number 800-899-7890 or visit our web site for the most current product and technical information at www.ramset-redhead.com
Spline ShankPART DIAMETER USABLE OVERALL
NUMBER In. (mm) DRILLING LENGTH LENGTHIn. (mm) In. (mm)