s Measuring, testing and recording equipment Catalog ART 2 • 1999 A number of products and systems can be combined as required. The essential data and standard configurations are provided for this purpose. Should you not find the required instruments straight away please get in touch with us. You will find our contact addresses at the end of catalog. Technical alteration rights reserved. Workshop equipment for the electrical trade Summary of new products 2-3 Summary of workshop equipment 4 The products and systems described in this catalog are manufactured and sold under application of a quality management system certified by DQS in accordance with ISO 9001 (Certificate Registration No.: 1784-04) . The DQS Certificate is recognized in all EQNet countries (Reg. No.: 1784-04). REG. NO. 1784-04 Page Multimeters, milliohmmeters calibrators, clip-on measuring instruments Summary of digital multimeters 1/1 Digital multimeters 1/2 Calibrators 1/5 Milliohmmeters 1/6 Accessories for the complete family 1/7 Graphical multimeter 1/8 Bench-top multimeter 1/9 Analog multimeters, MULTIZET 1/10 Multimeter accessories 1/11 Clip-on measuring instruments 1/12, 1/17, 1/18, 1/19 Mini clip-on ammeters 1/12, 1/14 Clip-on multimeters 1/13 Clip-on amperemeters 1/17 Industrial and power measuring instruments, oscilloscopes Summary 2/1 Accessories and software for testers 2/7, 2/8 Equipment tester 2/9 Revitester 0701 2/10 Isolation tester, earth tester, FI-tester 2/11 Isolation tester Isowid 2/12, 2/16 Isolation measuring instruments 2/14 Earth tester 2/20 Test panels 2/20 Single-knob measuring bridge wiring tester 2/23 Decades 2/23 Phase-sequence indicators 2/25 Temperature meter THERMIZET 2/25 Harmonic analyzer 2/26 Cilp-on Multi-Power-Meter 2/27 Oscilloscopes 2/29 Speed measuring instruments / tachometers 2/34 Temperature and climate measuring instruments 2/35 Further products from our range Summary 3/1 Function generators, timers and frequency meters 3/2 Power supply units 3/3 Precision und simulation instruments 3/4 Process recorder, oscilloscopes 3/5 Rented equipment 3/9 Appendix 3/10 Calibration service 3/13 We also offer in addition 3/14
24
Embed
Measuring, testing and recording equipmenttekhar.com/Programma/Siemens/KIPiA/Izmeritel_pribory/Pdf_pict/1e.… · Measuring, testing and recording equipment Catalog ART 2 • 1999
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
s
Measuring,testing andrecordingequipment
Catalog ART 2 • 1999
A number of products and systems can be combined as required.The essential data and standard configurations are provided for thispurpose.
Should you not find the required instruments straight away pleaseget in touch with us. You will find our contact addresses at the endof catalog.
Technical alteration rights reserved.
Workshop equipment forthe electrical tradeSummary of new products 2-3Summary of workshop equipment 4
The products and systemsdescribed in this catalog aremanufactured and sold underapplication of a qualitymanagement system certifiedby DQS in accordance withISO 9001 (CertificateRegistration No.: 1784-04) .The DQS Certificate isrecognized in all EQNetcountries (Reg. No.: 1784-04).
REG. NO. 1784-04
Page
Multimeters, milliohmmeterscalibrators, clip-on measuring instrumentsSummary of digital multimeters 1/1Digital multimeters 1/2Calibrators 1/5
Milliohmmeters 1/6Accessories for the complete family 1/7Graphical multimeter 1/8
Measur. V DC 400 mV ...600 V 30 mV ...1000 30 mV ...1000 V 300 mV ...1000 V 300 mV ...1000 Vmodes ± (0.5 % M.V. +2d.) ± (0.25 % M.V. +1d.) ±(0.1 % M.V. +1d.) ± (0.02 % M.V. +0.005% v.B. +5d.) ±(0.05 % M.V. +3d.)
V AC 400 mV ... 600 V 3 V ... 1000 V 3 V ... 1000 V 300 mV ... 1000 V 300 mV ... 1000 V±(1 % M.V. +2d.) ± (0.75 % M.V. +1d.) ± (0.75 % M.V. +3d.) ±(0.2 % M.V. +30d.) ±(0.3 % M.V. +30d.)
A DC 40 mA ... 10 A 3 mA ... 10 A 300 µA ... 10 A 300 µA ... 10 A 300 mA ... 10 A± (0.8 % v.M. +2d.) ±(1.0 % M.V. +2d.) ±(1.0 % M.V. +2d.) ± (0.05 % M.V. +0.01% v.B. +5d.) ±(0.2 % M.V. +10d.)
A AC 40 mA ... 10 A 30 mA ... 10 A 3 mA ... 10 A 300 µA ... 10 A 300 mA ... 10 A± (1% v.M. +5d.) ±(1.5 % M.V. +2d.) ±(1.5 % M.V. +4d.) ±(0.5 % M.V. +30d.) ±(0.5 % M.V. +30d.)
Including 1 pair measuring leads with test 1 pair measuring leads with test 1 pair measuring leads with test prods, 1 pair measuring leadsin delivery prods, operating instructions, prods, operating instructions, operating instructions, protective cap, leads with test prods,
protective cap protective cap,) 9 V battery, test 2 x 1.5 V battery, DKD test report, operating instructions, 9 Vreport, rubber protective sleeve rubber protective sleeve (in the case of battery, operating
B1106, 3 measurement connection instructions, test report,cables instead of 1 pair) rubber protective sleeve2 x 1.5 V batteries 1 x 9 V batteries
multimeter
1/2
1
Siemens ART 2 · 1999
Digital multimeter B1100 and B1101
Effective value for distorted waveform (B1101)The built-in effective value transducer allows for effective valuemeasurement (TRMS) independent of waveform for alternatingmagnitudes (AC).
Automatic / manual measuring range selection
Selection of input resistance for voltage measurement10 MΩ and 400 kΩFrequency and capacity measurement, dielectric and diodetesting, min., max. and hold memory for increased measuringcomfort and convenience
Fast analog display facilitates trend analysis. The high resolution ofthe digital display permits 0.1 V resolution even at 380 V.
Overload protection up to 500 V in all measurement functions andranges: sophisticated protection technology prevent premature damage.
1) With „REL“, zero setting,without zero setting +300 digits in the 4 nF range, +30 digits in the 40 nF range
Technical data
Dig. display inherent dev.at ref. conditions ±(...% of MV.+...digit)
Meas.function
Meas.range
Resolution Input impedance100pF // X Ω
V / ~ V400Ω
Voltage Dropapprox.
Open circ. voltage
Ordering Data
fmin V
General data
V ~400kΩ
A
Designation Order No.
• Power supply
B11002 ea. 1.5 V mignon cellAlkaline manganese dry cell per IEC LR 6B11019 V flat cell battery;Alkaline manganese dry cell per IEC 6 LR 61
• Electrical safety
Protection class II perIEC 1010-1/EN 61010-1/VDE 0411-1
Overvoltageclassification II IIINominal voltage 600 V 300 VContamination level 2 2Test voltage 3.7 kV ~ per
IEC 1010-1/EN 61010-1/VDE 0411-1
• Mechanical design
Protection Instruments: IP 50Connector sockets: IP 20VDE 0411-1
Dimensions W x H x D:92 mm x 154 mm x 25 mm
Weight Approx. 0.2 kg with battery
• Display
LCD-Display field (50 mm x 30 mm) withanalog and digital display, and with displayof measurement unit, type of current andvarious special functions.Measurement rate2 measurments for U, I, und Ω1 measurement for capacitive andfrequency measurements
• Ambient conditions
Operatingtemperaturerange -10 °C ... + 50 °CStoragetemperature -25 °C ... + 70 °Crange (without battery)Climate 2z/-10/50/70/75 %classification in compliance with
VDI/VDE 3540Relativehumidity 45 ... 75 %
V
V 400kΩ
V ~
A ~
Ω
F
Hz
40.00 mA 10 µA 450 mV400,0 mA 100 µA 1,5 V
0.8 + 2
10.00 A 10 mV 750 mV 1.5 + 540.00 mA 10 µV 450 mV400.0 mA 100 µV 1.5 V
600 V 1 V 10 MΩ ~400 kΩ400.0 mV 100 µV >20 MΩ ~400 kΩ 1.5 + 54.000 V 1 mV 11 MΩ ~400 kΩ400.0 V 10 mV 10 MΩ ~400 kΩ40.00 V 100 mV 10 MΩ ~400 kΩ
1 + 5
600 V 1 V 10 MΩ ~400 kΩ
multimeter
1/3
1
Siemens ART 2 · 1999
Multimeter B1102 and Multimeter B1103
Automatic Blocking System (ABS)The automatic blocking system prevents incorrect connection ofthe test leads and incorrect selection of the measured quantity.
Interface and software WinDATAThe multimeters are fitted with a serial RS-232 C interface throughwhich the measured values are transmitted
Root-mean-square value with distorted waveform
Autoranging / manual range selection
Continuity test
Overload warning
Protective holster for rough duty
1) Real effective value measurement (TRMS), 2) with zero setting: without + 50 digits, 3) without sensor
Meas.function
Meas. range Input impedance
Voltage dropapprox.
Open Circ. Voltage
Ordering Data
General data
V ~
Designation Order No.
B11
02
B11
03
MetraHit
Technical data
Reso-lution
Dig. display inherent dev.at ref. conditions ±(...% of MV.+...digits)
Precision multimeter (V, dB, A, Ω, F, Hz, ºC)Power meter (W, Var, VA, Wh, PF: only B1106)Triple display for simultaneous indication of 3 measurementvalues, Large 128 kB measurement value memory(metrahit 29S only), DKD calibration certificate provided,Accessory Windows software for measurement value processingand calibration via RS232 interface
Effective value for distored waveforms (TRMS)
Additional functions:Continuity testing with acoustic signal, event counting, eventduration measurement, overall time, stopwatch, data compare andwide-range capacitance measurement.
1) Lowest measurable frequency / 2) 45 ... 65 Hz, values < 300 digits are to be suppressed / 3) plus sensor deviation / 4) without installed comparison point
Meas.function
Meas.range
Ordering data
General data
Designation
Technical data
Resolution Dig. display inherentdev. at ref. conditions
Protection class II per IEC 61010-1/EN 61010-1/VDE 0411-1
Overvoltagecategory II IIIOperating voltage 1000 V 600 VContamination level 2 2Test voltage 5.55 kV - per IEC 61010-1/
EN 61010 / VDE 0411-1
• Ambient conditions
Operatingtemperaturerange -20 °C ... + 50 °CStoragetemperature -25 °C ... + 70 °Crange (without batteries)Climatic 2z/-20/50/70/75 %class in compliance
with VDI/VDE 3540relative max. 75 %,humidity without dew point
• Data interface
Datatransmission Optical transmission
through housing withinfrared light
• Mechanical design
Protection Devices: IP 50Connector jacks: IP 20
Dimensions 84 mm x 195 mm x 35 mmWeight Approx. 405 g mit batteries
• Included equipment
1 Multimeter, 1 cable set KS171 Operating instructions1 Protective case for operation under adverse conditions2 Batteries1 DKD-calibration certificate (B1106 only)
Calibration
1/5
1
Siemens ART 2 · 1999
Hand-held calibrator B1108-8CA/multimeter B1108-8CB/calibration set B1108/8CC
Universal calibration source:mA/mV ... V/°C (Pt100/1000/Ni 100/1000,thermocouple J, L, T, U, K, E, S, R, B, N)/30 ... 2000 W
Robust and EMC-safe design
Automatic jack lockout
Procedure and calibration value memory
Easy operation
Frequency and pulse group pulse generator
Ramp and stair-step functions
Modular extension to calibration system
Traceable test report in extent of delivery
Transmitter simulator (sink 0 ... 24 mA)
Current measurement 0 ... 24 A
The B1108 hand-held calibrator is used as a universal and precisioncalibration and simulation instrument for many electrical measurementtechnique parameters. It is outstandingly versatile in function and is usedfor calibrating components and instruments used for measurementparameter acquisition in process technology. It fulfils the requirements laiddown in DIN ISO 9000 and is provided as standard with a traceableworks certificate. As a result of its battery and accumulator operation it issuitable for mobile use on location as well as for stationary calibration,repair and development tasks.
Further data for CALIBRATOR B1108DisplayType of display 99 999 digits LCD with symbols
for operator guidanceInterface:Type RS232C, in accordance with
DIN 19241Date transfer optical with infrared light through
the casingTemperature range:in operation 0°C ... + 50°CPower supply:Batteries Standard: 3 x alkaline manganese
(IEC LR6)Electrical safety:Nominal installationvoltage 50 VTest voltage 500 VClass of protection IIMechanical construction:Degree of protection IP40, connection IP20Dimensions 84 mm x 195 mm x 35 mmWeight 0.4 kg with batteries
Fully automatic calibration of measuring transducers, transmitters,insulation amplifiers and measurement drawers is possible in but afew seconds with the calibration set including issuing certificate.The calibration set incorporates everything required for anautomatic calibration system: the B1108 calibrator with the BD232interface adapter and WinDATA for automatic calibration valueoutput including the B1108 multimeter with SI232 memoryadapter and WinDATA 10 for exact measurement of output valuesof the calibration object.
The set also includes cable, test probes and terminals, a chargerwith NiMH accumulator as well as carrying case.
Extract of relevant measurement ranges for the use of the B1108 –8CB multimeter in the calibration system:
To the greatest extent the other measuring functions are identical tothose of the B1103 multimeter, see Page 1/7. Please send forseparate data sheet 7KB1108-8CB.
Scope of delivery, calibration set1 Calibrator B1108 including cable set and operating instructions
1 Multimeter B1108 including cable set and operating instructions
1 Interface adapter 7KB9102-8EM
1 Memory adapter 7KB9102-8EH
1 Carrying case F840
1 RS-232 bus cable, 2 m, 9 pole/9 pole
1 Software package WinDATA 10, 3 1/2” program diskette and
operating manual
1 NiMH set (charger and 6 only NiMH accumulators)
1 Cable set comprising:
4 instrument leads (2 black, 1 red, 1 yellow)
with angle and straight plugs, 4 insert alligator clips,
4 insert adapters, 2 mm
Ordering DataDesignation Order No.Calibration set 7KB1108-8CC
Ordering DataDesignation Order No.Calibrator B1108 7KB1108-8CAMultimeter B1108 7KB1103-8CB
Milliohmmeter
1/6
1
Siemens ART 2 · 1999
Milliohmmeter B1107
FeaturesTen measuring ranges from 20 mΩ ... 20 MΩOnly one meter for many applications
Four-wire measurementSuppresses effects of line and contact resistances
Compact and ruggedFor harsh applications in service and laboratory
Overload protectionProtects the instruments in the case of accidental connectionto the line voltage
Calibration certificate which can be traced backReduces operating cost when used in ISO 9000Quality Systems
ApplicationsThe milliohmeter B1107 is a rugged, precise and reliable instrumentwhich is suited for many a task in operation, service on the site, aswell as for exact measurements in the laboratory:
Adjustment of shunts in instrumentation
Tests of electrical connections on bus bars in opencast miningin industry and household
Testing of cable resistance, wiring, shunts of circuit boards andthick-film circuits
Measurement of the contact resistance of relays, contactorsand circuit breakers
Measurement of the resistance of fuses as well as of the leadresistance in power circuits
Testing of the winding resistance in transformers, coils, small motors etc.
The milliohmmeter B1107 is the modern replacement of the knownmeasuring bridges TH2 (Thompson) and WH2 (Wheatstone) andoffers an improved range span, higher measuring accuracy and easierreading. As wide-range resistance measuring instrument, it acquiresthe resistance value by passing a measuring current through theresistor, conductor or contact. The ratio measurement is used asmeasuring principle.
That is why its measuring accuracy is only defined by the installedprecision resistors and the accuracy remains stable over the entirelifespan of the meter. The measuring current at a time is selected bythe position of the range selector switch and is 0.1 A on the twolower ranges.
AccessoriesCarrying case with compartment 7 KB9102-8EA X
Carrying case 7 KB9102-8EB X X X X X
Cable set 7 KB9102-8EC X
Carrying case for multimeter case set 7 KB9102-8ED X X X X
Cable set 7 KB9102-8EF X X X (X)
Probe for voltage measurement in 7 KB9102-8EG X X X Xelectrical power installations up to 1000 V
Memory adapter (SI232) 128 kB with 7 KB9102-8EH X X Xintegrated real time clock including battaries
RS232 - bus cable 7 KB9102-8EJ X X X X
Single channel memory pack with memory 7 KB9102-8EK X X Xadapter 7 KB9102-8EH, recording analysissoftware, 7KB9102-8EP, RS232 - cabeland installation instructions
Four-channel memory pack with 4 only 7 KB9102-8EL X X Xmemory adapters, 7KBB9102-8EH, recordingand analysis software, 7KB9102-8EP, RS232 -cable and installation instructions
BD232 bi-directional interface adapter, 7 KB9102-8EM Xinfrared interface, for infrared interfaceconversion to serial interface RS232 C
Mains adapter NA 4/500 for B1105-8AA, 7 KB9102-8EN X XB1107-8AA and B1108-8CASoftware WINData 10 for the B1102 to B1106 7 KB9102-8EP X X Xmultimeters for presentation and processingof measured data in the PC.The B1105 and B1106 multimeters can beprogrammed for part functions.
Single channel BD232 pack with / KB9102-8ER X X X7KB9102-8EM bi-directional interface adapter,WINData 10 software 7KB9102-8EP, RS232 cable and installation instructions.PT1000 immersion sensor for measurements 7 KB9402-8ES X X Xin gase and liquids, - 50 ºC to 220 ºCStandard PT100 temperature sensor for 7 KB9402-8ET X X Xsurface and iimersion measurements,- 40 ºC to 600 ºC, Class AHigh voltage probe 3kV / 3 V 7 KB9402-8EU X X X XHigh voltage probe 30kV / 30 V 7 KB9402-8EV X X X XKC2 Kelvin clips 7 KB9102-8EW X(1 pair) for normal objectsKC3 Kelvin clips 7 KB9102-8FA X(1 pair) for smaller objectsfor example coils, componentsWinDATA 90 software for B1108 7KB9102-8FB Xcalibrator control and calibrator resultevaluation
Digital multimeters
1/8
1
Siemens ART 2 · 1999
B1036 graphical multimeter
Ordering data
Designation kg Order No.
Graphical Multimeter B1036 7KB1036-8AAcarrying case on request
A completely new class of universal hand-held multimeters hasbeen made available with the B1036 graphical multimeter.
Most progressive multimeter functions combined with signal formand trend presentation.
A high-precision heavy-duty multimeter with analog, digital andgraphic display.
Features
Digital display range
RMS measurement
AutoDiode
High impedance input
Resistance, conductivity, capacitance
Continuity test
Pulse duty factor, pulse width, period, frequency
Minimum, maximum and average value with time
Relative mode
Touch hold and peak value acquisition
dB with selectable reference impedances
Automatic and manual range switchover
Smoothing
Logic activity
Component test
LCD background illumination
Internal battery charging
Extra signal form memory
RS 232 interface (visually isolated)
Included in delivery:
Set of industrial test cables, external power pack, NiCd accupack, RS 232 cable and VIEW software.
Current supply: external power pack, NiCd battery set
Weight: without battery: 1.1 kg. with battery: 1.4 kg.
Dimensions (h x b x d): 246.4 mm x 137.2 mm x 69.9 mm
The multimeter dual display mode offers two high precisionnumerical displays with maximum 32,000 digits and an analogneedle graph for easy readable presentation of dynamic signals incombination mode. The digital measured values and signal form areshown simultaneously.
Direct measurements of AC and DC voltages and currents,resistance and conductivity, capacity, frequency, pulse duty factor,pulse width, period and dB can be taken in meter mode.
Interference signals, noise, signal distortion as well as intermittentfields and pitch are quickly recognised. Signal form display to 1 MHzband width.
TrendGraph registers the measured values at intervals of 1 secondto 15 minutes and in this way can provide measured value recordsup to 30 hours.
The logic activity test serves for locating interference in digitalelectric circuits. It shows status changes to 10 MHz or whether thecircuit has “hung up” high or low.
The integrated RS 232 interface ensures fast and easy data transmis-sion to a printer or PC. It is also possible to load reference signal forms -or component signatures - in the graphical multimeter.
Safety: 1000 V IEC-1010-1 Class III protection in all functions
Ft2 surface sensor 0,07 7KB9402-8EDPt 100. Class B, -50 to +500 °C0.6 % of meas. value +0.5 °C,sensor length 140 mm,total length 280 mm,supply lead 1.5 m long with2 Siemens earthing pin plugs
Ft1 surface sensor 0.07 7KB9402-8EBMo 1000. Class A,-50 to +250 °C0.5 % of meas. value +0.6 °C,sensor length 150 mm,total length 270 mm,supply lead 1.5 m long with2 Siemens earthing pin plugs
Temperature probe, 0.2 7KB9102-8DEfor surface, air and immersionmeasurements,Meas. range -60 to +800 °C,Error limits: 1% of meas. value +2 mVOutput voltage DC 1 mV/°C,with 9-V battery IEC 6LF22
Surface sensor 7KB9401-8AV50 to +500 °C, 150 mm
Knife-edge sensor 7KB9401-8AW-50 to +800 °C, 150 mm
Gas and air sensor 7KB9401-8AX-50 to +250 °C, 150 mm
Flexible sensor 7KB9401-8AY-50 to +1000 °C, 1 m
Summary
Technical and ordering data
B11
00 -
B11
06
µA-M
ULT
IZE
T
multimeter
1/2
1
Siemens ART 2 · 1999
kg Ordering No.
Safety test prods 0,05 7KB9102-8BE1 pair, red and black
Technical and ordering data
B11
00 -
B11
06
µA-M
ULT
IZE
T
Safety clips 0,03 7KB9102-8BH1 pair, isolated, red and black
Safety clamp-type test prods 0,05 7KB9102-8BF1 pair, red and black
Safety cable lugs 0,01 7KB9102-8BJ1 pair, black
Safety test leads 0,14 7KB9102-8BC1 pair, 1.5 m long, red and blacktest voltage 2 kV with test prods
Safety connector adapters 0,01 7KB9102-8BG1 pair, red
Ever-ready carrying case for MULTIZET (a) 0,5 M05859-A1Dimensions: 135 mm x 90 mm x 205 mm
Technical data 7KA1404-8AA 7KA1404-8BA 7KA1404-8CA 7KA1412-8BA
Mini clip-on ammeter, current converter
0.001 - 15 A ~ 0.1 A .. 24 A ~
Measuring range 15A - 180 A ~ 0.01A - 100 A ~ 1 A - 150 A ~ 0.5 A .. 240 A ~
Power factor measurements (for sinusoidal signals)
Meas. range Resolution Frequency range Error limits
ind 0.3...1...0.3 cap 0.01 10...66 Hz1.5 % o.m. range+ 1 digit
Measurement rate Approx. 2 measurement/s
Frequency measurements
Meas. range Resolution Voltage range Error limits
5...200 Hz 0.1 Hz200...550 Hz 1 Hz
20...750 V0.5 % o.m.range
550...775 Hz 2 Hz + 1 digit775...999 Hz 3 Hz
Measurement rate Approx. 2 measurement/s
Analog output Switcheable between real timewaveform and RMS value
Output voltage 5 mV/A at 0...200 A1 mV/A at 0...1000 A
Reference conditions 23 °C ± 1 °C, 50 Hz (sinusoidal),conductor in center of clip
Working temperature range 0 to 45 °COpening 60 mm dia. for round conductors,
60 mm x 25 mm for flat conductors
Dimensions (w x h x d) 90 mm x 65 mm x 250 mm
Ordering data
Designation kg Order No.
B4203 clip-on multimeter 0.5 7KB4203-8AAwith battery, 1 pair of safety test leadsand measurement leads for analog output
Ever-ready carrying case 0.1 7KB4203-8BA
Star-point resistor 0.1 7KB4203-8BBfor measurement in three-wire three-phasenetworks without neutral conductor,Ueff = 3 x 750 V, test voltage 6 kV,protection class II to DIN VDE 0411
0 to 400 Ω 0.1 Ω ± 1 % of m. v.0 to 4 kΩ 1 Ω ± 3 digits
Continuity testContinuous audible signal with resistance < 50 ΩDiode testIndicates conducting-state voltages up to 2 V or diodesOpen circuit (max. 3.2 V): Error limits ±1 % of meas. value ± 2 digits0.3 mA short-circuit
Display 4-digit, digital LCD displayCable diameter 1 x 35 mm or 2 x 20 mmOperating temperature 0 to 50 °CIncluded in delivery Battery, case, measurement leads and
0 to 400 Ω 0.1 Ω ± 1 % of m. v.0 to 4 kΩ 1 Ω ± 3 digits
Continuity testContinuous audible signal with resistance < 50 ΩDiode testForms continuity voltages from diodes to 2 VOpen circuit (max. 3.2 V): Error limits ±1 % of meas. value ± 2 digits0.3 mA short-circuit
Display 4-digit, digital LCD displayCable diameter 1 x 50 mm or 2 x 30 mmOperating temperature 0 to 50 °CIncluded in delivery Battery, case, measurement leads and
instructions
Clip-on voltammeter LH1020:Alternating currents /pp up to 1000 A
DC/AC voltages up to 600 V
Resistance measurement, diode and continuity test
Automatic range and zero setting
Hold function for measured values
High accuracy
Satisfies the ICE 1010 and EMC standards according to CE
In addition for clip-on voltammeters LH1025:True RMS measurement (TRMS) with distortedand non-sinusoidal alternating currents and voltages(peak factor 6)
Hold function for display ofmaximum measured value
Clip-on voltammeter LH630Direct currents up to 1000 AAlternating currents up to 600 A
DC/AC voltages up to 600 V
Resistance measurement, diode and continuity test
Automatic range and zero setting
High accuracy
Satisfies ICE 1010 and EMC standards according to CE
In addition for clip-on voltammeter LH635:True RMS measurements withdistorted and non-sinusoidal alternatingcurrents and voltages (peak factor 6)
Hold function for display of maximummeasured value
Max. overload 1000 VMeasuring ranges 400 V, 600 V(autom. range selection)Accuracy ± 1 % of measured value ± 3 digits 1)
Resolution 100 mV (400 V range); 1 V (600 V range)Crest factor 6 for V < 1000 V surgeInput impedance 1 M ΩResistance, continuity anddiode test
Ω-measuring ranges 400 Ω, 4 kΩ(autom. range selection)Ω-resolution 0.1 Ω (400-Ω range), 1 Ω (4-kΩ range)Ω-accuracy ± 1 % of measured value ± 3 digits 1)
Continuity buzzer with )))) key, on and off;(only Ω range) buzzes when resistance < 50 ΩInput protection Ω and diode test To 600 V, DC or effective value(sinusoidal form)
Diode test max. 3.2 V Displays continuity voltages from diodesOpen circuit 0.3 mA short-circuit up to 2 V
Diode test accuracy ± 1 % of measured value ± 2 digits
Frequency range(measurement and analog output)
Only AC true RMS V and A 15 Hz ... 1 kHz 3) 4)
DC RMS A DC + 15 Hz ... 1 kHz 3) 4)
DC V and A only DC
Display
Dimensions and type 4-digit, liquid-crystal display,12 mm character
Status display weak battery, measured value holdingfunction, surge (max. value), AC, DCdiode test, Ω, )))) (continuity test)
Refresh rate 3 times/s
Technical data, part 2 (common data)
Technical data, part 1
Model LH240 LH1040 LH2040
Contactless current measurement
Measuring ranges (autom. range selection) 40 A, 200 A 400 A, 1000 A 400 A, 2000 A
Measurement mode DC or AC true RMS value or only DC
Resolution 10 mA (40 A range) 100 mA (400-A range) 100 mA (400-A range)100 mA (200 A range) 1 A (1000-A range) 1 A (2000-A range)
Accuracy ±1.3 % of measured value + 3 digits 1)
Crest factor max. 6 for true RMS value measurement
Max. measurable value 200 A DC or AC peak 1000 A DC or AC peak 2000 A DC or AC peak
Max. overload 10000 A
Analog output 2)
Switchable actual or RMS value 5 mV / A 1 mV / A 0.5 mV / A(100 ms) output
Accuracy ±1.3 % of measured value ± 1 mV 1)
Power supply
Battery type 9-V alcaline battery: MN1604, PP3. IEC6LR61 or similar
Battery service life Approx. 40 hours
Mechanical data
Dimensions (h x w x d); 251 mm x 98 mm x 52 mmWeight 500 gCable diameter 1 x 50 mm dia. or 2 x 30 mm dia.Jaw opening 55 mm
Ambient data
Operating temperature 0 °C ... 50 °CTemperature coefficient (current) ± 0.1 % of measured value per °CStorage temperature -20° ... 60°Protection classAll versions fulfill IEC 1010-1. 600-V operation, installation category III,contamination degree 2.
Max. permissible voltages
Current measurements 600 V AC RMS or DC between(non-isolated conductor) non-insulted conductor and earth
Voltage measurement 600 V AC RMS without DC betweeninput terminals or between currentconductor and local earth
Accurate, rugged, versatile, reliable
Three versions: 200 A, 1000 A and 2000 A
AC and DC amps, volts, Ω, diode and continuity test
Jaw accommodates 50 mm dia. or 2 x 30 mm dia. cables
True RMS measuring of complex waveforms and analysisof AC and DC components
Auto-ranging and auto-zeroing
Excellent accuracy, even with distorted and sinusoidalcurrents and voltages
Display hold mode and max. value storage (surge)
Analog output for recorders, loggers or oscilloscopes
Satisfies IEC 1010 and EMC standards (CE)
Note:
1) All given accuracies are valid at 23 °C ± 1 °C2) Analog output of plug-in adapter with normal BNC output jack3) At given accuracy: 5 kHz (-3dB)4) True RMS each 100 ms
1/16
Clip-on measuring instruments
1/13
1
Siemens ART 2 · 1999
Clip-on ammeters and clip-on current transformers
The PR 2000 current transformer was developed as clip-on tool formultimeters, oscilloscopes and recorders. The application ofsophisticated hall effect technology permits highly accurate measure-ment of AC and DC to 2000 A. The large jaw also permits measure-ments on current rails.
AC/DC Clip-on current transformer PR2000
Meas. range 2000 A DC or AC peakConductor dielectric strength 50 mm diameterAccuracy 1 % ± 0.5 AFrequency range DC - 10 kHzOutput 1 mV/AConnection 2 m connection cable
with 4 mm banana plugsBattery service life 75 h in continuous operation
International safety (IEC 1010) and EMC standards are kept, of course.
Technical data
Ordering data
Designation kg Order No.
Clip-on current transformer PR30 7KA1407-8BDClip-on current transformer PR20 7KA1407-8BBClip-on current transformer PR200 7KA1407-8BCClip-on current transformer PR2000 AC/DC 7KA1407-8CA
PR30 PR20 PR200
Clamp-on ammeter range A1407
Model PR30 PR20 PR200
Technical data
Clip-on current transformer B4202
Dimensions (h x w x d 196 x 71 x 31 mm / 7.71 x 2.80 x 1.20 "
Weight 295 g / 0.65 lbs.
Jaw 1 x 30 mm /1.16 inch diameter cable
Maximum permissible voltagesmeasurement 300 V AC effective or DC between non-(bare conductor) isolated earth conductor and earth
Technical data
Non-evasive current measurementranges 400 A , 1000 A(automatic range adjustment)Measuring principle Effective value of AC or DC
Resolution 100 mA (range 400 A), 1 A (range 1000 A)
Basic accuracy ± 1.3 % of display, ± 5 digits
Measurable maximum load 1000 A DC or AC current,peak value
Maximum overload 10,000 A
FrequencyAC A 40 to 400 HzDC A only DC
DisplaySize and type LCD with 4000 elements
Digit size 10 mm/0.4 inch
Status display weak battery, polarity
Display change frequency 3 times per second
Power supplyBattery type 9 V alkaline: MN1604. PP3 IEC 6LR6 1
Current ranges 20 A B/30 A - 20 A B/30 A - 20 A B/30 A - 200 A B/300 A-
Resolution ± 1 mA ± 1 mA ± 10 mA ± 100 mA
Output 100 mV/A 100 mV/A 10 mV/A 1 mV/Arange
Measurement ± 1 % ± 1 % ± 1 % ± 1 %accuracy ± 2 mA ± 2 mA ± 0.03 mA ± 0.3 mA
Frequency Direct current Direct current Direct current Direct currentrange to 100 kHz to 20 kHz to 10 kHz to 10 kHz
Response time < 1 µs < 1 µs < 10 µs < 10 µs
Dielectric 3.7 kVeff - 3.7 kVeff - 3.7 kVeff - 3.7 kVeff -strength 50 Hz, 1 min. 50 Hz, 1 min. 50 Hz, 1 min. 50 Hz, 1 min.
Opening 19 19 19 19in mm
1/17
Clip-on measuring instruments
1/12
1
Siemens ART 2 · 1999
Clip-on current converter
Clip-on current converter A1406
Clip-on current converter A1407
Clip-on current converter A1408
Nominal current 500 AMeasuring range 4 to 500 ATransformation ratio 1000: 1 (/AC 1 mA/1 A)Frequency range 48. . .1000 HzLoad max. 5 ΩError limits 3% of meas. value
+ 0.4 A (at ≤ 5 Ω)Working voltage Ueff max. 660 VTesting voltage 4 kVNo-load voltage max. 40 V, no risk disconnection of
secondary circuit possiblePassage opening- for round lead 30 mm dia.- for flat lead 63 mm x 5 mmMeasurements (w x h x d) 66 x 34 x195 mmConnection 4 mm jackWeight 0.45 kg
Technical data
Parameters Multimeter and pick-up measuringsensor
Current measuring range 200 A AC / 300 A DC1000 A AC peak / 1000 A DC
Resolution 100 mAOutput sensitivity 1 mV/AMeasuring accuracy ±1% ±0.5 AFrequency range DC to 10 kHzResponse time < 10 µSDielectric strength 3.7 kW - 50 Hz, 1 minuteOpening 31 mm max.
Technical data
Parameters Multimeter and pick-up measuringsensor
Nominal current 1000 A ACMeasuring range 0.1 ... 1200 A ACTransformation ratio 1000 : 1Frequency range 30 ... (48..65) ... 5000 HzLoad < 5 OhmMeasuring accuracy < 0.75% at 100% hOpening 54 mm max.
Technical data
Ordering data
Designation kg Order No.
Clip-on current converter A1406 0.45 7KA1406-8AA
Clip-on current converter A1407 0.4 7KA1407-8BA
Clip-on current converter A1408 0.65 7KA1408-8BA
1/18
Clip-on measuring instruments
1/13
1
Siemens ART 2 · 1999
Technical data A1403 A1403 II
Measuring ranges a / s 30/300 A; 300/3000 A AC 30 / 300 / 3000 A AC
Output sensitivity Measuring range a = 100 mV/A and 10 mV/A 100 mV / 10 mV / 1 mV pro As = 10 mV/A and 1mV
Maximum output signal 3 VAC RMS or 4.2 V pK 3 VAC RMS or 4.2 V pk
Accuracy Amplitude ± 1% of measuring range ± 1% of measuring range