UP SUNROOM RM.01 HALLWAY RM.02 B-1 FE OU-1 IU-1 IU-2 HRV-2 10"Ø 8"Ø 8"Ø 10"Ø 10"Ø 175CFM 175CFM 14"X14" HWC-1 OU-2 BB 28' AHU-1 1"Ø BD BD AHU-1 FD FD 'B' 'A' 'A' UP SUNROOM RM.01 HALLWAY RM.02 HVAC LEGEND ## A B BD BB ## FD FE M-1 NEW HVAC LAYOUT - FLOOR PLAN Mills Phase Three Tel. 613-592-1677 M.E. DEC 14/17 T.V. AS SHOWN 411 Country Street ARCH D - 24"X36" ALMONTE, ONTARIO IN CONSIDERATION OF THE RECEIPT OF THIS DOCUMENT, THE RECIPIENT AGREES NOT TO REPRODUCE, COPY, USE OR TRANSMIT THIS DOCUMENT AND/OR THE INFORMATION THERIN CONTAINED, IN WHOLE OR IN PART, OR TO SUFFER SUCH ACTION BY OTHERS, FOR ANY PURPOSE, EXCEPT WITH THE WRITTEN PERMISSION OF TTF ENGINEERING AND FURTHER AGREES TO SURRENDER SAME TO TTF ENGINEERING UPON DEMAND. COPYRIGHT TTF ENGINEERING TTF Engineering Unit 205 - 1600 Merivale Road Ottawa, ON K2G 5J8 NEW HVAC LAYOUT - FLOOR PLAN SCALE: 1:40 NEW INFLOOR HEATING LAYOUT - FLOOR PLAN SCALE: 1:40 1 1 1 3 2 4 1 5 6 7 8 9 10 11 2
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
UP
SUNROOM
RM.01
HALLWAYRM.02
B-1
FE
OU-1
IU-1
IU-2
HRV-2
10"Ø
8"Ø8"Ø
10"Ø
10"Ø
175CFM
175CFM
14"X14"
HWC-1
OU-2
BB
28'
AHU-1
1"Ø
BD
BD
AHU-1
FD
FD
'B'
'A'
'A'
UP
SUNROOM
RM.01
HALLWAYRM.02
HVAC LEGEND
##
A
B
BD
BB
##
FD
FE
M-1
NEW HVAC LAYOUT -FLOOR PLAN
Mills Phase Three
Tel. 613-592-1677
M.E.
DEC 14/17T.V.
AS SHOWN
411 Country Street
ARCH D - 24"X36"
ALMONTE, ONTARIO
IN CONSIDERATION OF THE RECEIPT OF THIS DOCUMENT,THE RECIPIENT AGREES NOT TO REPRODUCE, COPY, USEOR TRANSMIT THIS DOCUMENT AND/OR THEINFORMATION THERIN CONTAINED, IN WHOLE OR INPART, OR TO SUFFER SUCH ACTION BY OTHERS, FOR ANYPURPOSE, EXCEPT WITH THE WRITTEN PERMISSION OF TTFENGINEERING AND FURTHER AGREES TO SURRENDERSAME TO TTF ENGINEERING UPON DEMAND.
COPYRIGHT TTF ENGINEERING
TTF Engineering Unit 205 - 1600 Merivale Road
Ottawa, ON K2G 5J8
NEW HVAC LAYOUT - FLOOR PLANSCALE: 1:40
NEW INFLOOR HEATING LAYOUT -FLOOR PLANSCALE: 1:40
1
1
1
3
2
4
1
5
6
7
8
9
10
11
2
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
THERMOSTAT C/W CONTROL WIRING
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
T
AutoCAD SHX Text
NEW SQUARE DIFFUSER
AutoCAD SHX Text
'A' INDICATES DIFFUSER TYPE
AutoCAD SHX Text
EXISTING DUCTWORK
AutoCAD SHX Text
NEW DUCTWORK
AutoCAD SHX Text
DUCTWORK C/W 1" ACOUSTIC INSULATION
AutoCAD SHX Text
## INDICATES AIRFLOW (CFM)
AutoCAD SHX Text
(REFER TO SPEC)
AutoCAD SHX Text
ACOUSTICALLY INSULATED RETURN TRANSFER DUCT
AutoCAD SHX Text
LOUVERED RETURN GRILLE
AutoCAD SHX Text
'B' INDICATES GRILLE TYPE
AutoCAD SHX Text
(REFER TO SPEC)
AutoCAD SHX Text
BALANCING DAMPER
AutoCAD SHX Text
'B' INDICATES GRILLE TYPE
AutoCAD SHX Text
(REFER TO SPEC)
AutoCAD SHX Text
DESTRATIFICATION FAN
AutoCAD SHX Text
HYDRONIC BASEBOARD HEATER
AutoCAD SHX Text
##- LENGTH (FT)- LENGTH (FT)
AutoCAD SHX Text
FIRE DAMPER
AutoCAD SHX Text
FIRE EXTINGUISHER
AutoCAD SHX Text
S
AutoCAD SHX Text
SPEED CONTROLLER
AutoCAD SHX Text
NEW
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
DEMOLITION
AutoCAD SHX Text
%%ULINETYPE LEGEND
AutoCAD SHX Text
DRAWING No.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWING
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
No.
AutoCAD SHX Text
PROJECT NORTH
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
STAMP
AutoCAD SHX Text
BY
AutoCAD SHX Text
1
AutoCAD SHX Text
DEC 19/17
AutoCAD SHX Text
ISSUED FOR PERMIT
AutoCAD SHX Text
SIZE:
AutoCAD SHX Text
ME
AutoCAD SHX Text
2
AutoCAD SHX Text
FEB 27/18
AutoCAD SHX Text
ISSUED FOR TENDER
AutoCAD SHX Text
TV
AutoCAD SHX Text
PROVIDE NEW 3 TON INDOOR UNIT (IU-1) & 2 TON INDOOR UNIT (IU-2) FOR DUCTLESS SPLIT SYSTEM. CONNECT TO OUTDOOR UNITS (OU-1, OU-2) RESPECTIVELY, VIA REFRIGERANT PIPING. PROVIDE WALL MOUNTED REMOTE CONTROLLER. REFER TO DUCTLESS SPLIT SCHEDULE ON DRAWING M-2 FOR SPECIFICATIONS.
AutoCAD SHX Text
%%UDRAWING NOTES:
AutoCAD SHX Text
1
AutoCAD SHX Text
%%uGENERAL NOTES:
AutoCAD SHX Text
1
AutoCAD SHX Text
PROVIDE 24"X24" SQUARE DIFFUSERS AS SHOWN. BALANCE DIFFUSERS AS INDICATED.
AutoCAD SHX Text
2
AutoCAD SHX Text
PROVIDE BALANCING DAMPERS AT EACH FLEXIBLE DUCT TAKEOFF.
AutoCAD SHX Text
3
AutoCAD SHX Text
MAXIMUM FLEXIBLE DUCT NOT TO EXCEED 10FT LONG IN ANY SINGLE SECTION.
AutoCAD SHX Text
PROVIDE NEW HYDRONIC HEATING MANIFOLD AS SHOWN. HOT WATER SUPPLY & RETURN PIPING TO BE CONNECTED BACK AT MANIFOLD.
AutoCAD SHX Text
%%UDRAWING NOTES:
AutoCAD SHX Text
1
AutoCAD SHX Text
PROVIDE NEW 350CFM HEAT RECOVERY VENTILATOR C/W TIME CLOCK. CONNECT SUPPLY DUCT TO DIFFUSERS AS SHOWN. PROVIDE FRESH AIR INTAKE & EXHAUST WEATHERHOODS AT EXTERIOR WALL. PLUMB CONDENSATE TO FLOOR DRAIN IN MECHANICAL ROOM.
AutoCAD SHX Text
2
AutoCAD SHX Text
PROVIDE NEW 14"X14" SIDEWALL EGGCRATE SUPPLY GRILLE FOR HRV RETURN AIR.
AutoCAD SHX Text
3
AutoCAD SHX Text
PROVIDE NEW 140,000BTU/H BOILER FOR INFLOOR HYDRONIC HEATING. PROVIDE COMBUSTION AIR INTAKE & VENTING AT EXTERIOR WALL. VENT AS PER MANUFACTURERS INSTRUCTIONS. PLUMB CONDENSATE TO FLOOR DRAIN IN MECHANICAL ROOM.
AutoCAD SHX Text
4
AutoCAD SHX Text
PROVIDE NEW 1" NATURAL GAS PIPING FOR NEW BOILERIN MECH ROOM. CONNECT TO EXISTING GAS SUPPLY MAIN.
AutoCAD SHX Text
5
AutoCAD SHX Text
%%uGENERAL NOTES:
AutoCAD SHX Text
1
AutoCAD SHX Text
PROVIDE NEW INFLOOR RADIANT HEATING PEX PIPING AS SHOWN.
AutoCAD SHX Text
PROVIDE NEW 34,000BTU/H, HOT WATER COIL, HWC-1. INSTALL INLINE WITH HRV SUPPLY DUCT AS SHOWN. PROVIDE DUCT MOUNTED THERMOSTAT FOR CONTROL.
AutoCAD SHX Text
6
AutoCAD SHX Text
PROVIDE NEW 30,000BTU/H, 20"X15" HOT WATER COIL, HWC-2 FOR EXISTING AIR HANDLING UNIT, AHU-1, IN MECHANICAL ROOM. EXISTING 6KW DUCT HEATER TO BE REMOVED.
AutoCAD SHX Text
7
AutoCAD SHX Text
PROVIDE NEW HYDRONIC BASEBOARD HEATER. BASEBOARD TO BE " TUBING, 657BTU/H/FT 12" TUBING, 657BTU/H/FTAT 150°F. SPECIFIED PRODUCT: HE3 SILENTFIN SERIES.
AutoCAD SHX Text
8
AutoCAD SHX Text
PROVIDE NEW DESTRATIFICATION FAN AS SHOWN. TYPICAL OF 2. FANS TO BE HUNG FROM CEILING BEAM. FANS TO BE HUNG TO 12FT A.F.F. FAN TO COME WITH WALL MOUNTED SPEED CONTROLLER.
AutoCAD SHX Text
9
AutoCAD SHX Text
PROVIDE NEW WALL HUNG FIRE EXTINGUISHER AS SHOWN.
AutoCAD SHX Text
10
AutoCAD SHX Text
PROVIDE FIRE DAMPER AS SHOWN. TYPICAL OF 2.
AutoCAD SHX Text
11
AutoCAD SHX Text
PROVIDE NEW THERMOSTAT FOR RADIANT INFLOOR HEATING SYSTEM. THERMOSTAT TO C/W FLOOR TEMPERATURE SENSOR.
IN CONSIDERATION OF THE RECEIPT OF THIS DOCUMENT,THE RECIPIENT AGREES NOT TO REPRODUCE, COPY, USEOR TRANSMIT THIS DOCUMENT AND/OR THEINFORMATION THERIN CONTAINED, IN WHOLE OR INPART, OR TO SUFFER SUCH ACTION BY OTHERS, FOR ANYPURPOSE, EXCEPT WITH THE WRITTEN PERMISSION OF TTFENGINEERING AND FURTHER AGREES TO SURRENDERSAME TO TTF ENGINEERING UPON DEMAND.
SERPENTINE TYPE WITH RETURN BENDS ON SMALLER SIZES AND RETURN HEADERS ON
LARGER SIZES. HEADERS TO BE CAST IRON WITH TUBES EXPANDED INTO HEADER,
SEAMLESS COPPER TUBE WITH SILVER BRAZED JOINTS OR PRIME COATED STEEL PIPE WITH
BRAZED JOINTS. REFER TO DRAWING M-2 FOR SPECIFIED PRODUCTS.
HYDRONIC BASEBOARD
1
2
" COPPER TUBING MECHANICALLY EXPANDED INTO FLANGED COLLARS OF EVENLY SPACED
ALUMINUM FIN, ONE TUBE END BELLED. ENCLOSURE TO BE MINIMUM 22GAUGE STEEL WITH
BACK AND TOP OF ONE PIECE, FRONT PANEL, END PANEL, CAPS, CORNERS, JOINER PIECES
AND FULL LENGTH DAMPER. HEAT CAPACITY PER LINEAR FT TO BE AS SPECIFIED IN
DRAWING M-1. REFER TO DRAWING M-1 FOR SPECIFIED PRODUCT. ALTERNATIVE PRODUCT
TO BE CONSIDERED.
BOILER
1. PROVIDE GAS-FIRED HOT WATER CONDENSING HEATING BOILER. BOILER SHALL BE
FABRICATED OF HIGH GRADE STAINLESS STEEL. THE HEAT EXCHANGER SHALL UTILIZE THE
HEATING SURFACE FOR MAXIMUM HEAT TRANSFER AND CONDENSATION FOR OPTIMUM
ENERGY SAVINGS. THE BOILER SHALL INCORPORATE A MODULATING COMPACT
CYLINDRICAL STAINLESS STEEL GAS BURNER WITH A HIGH ALLOY STAINLESS STEEL
SURFACE CAPABLE OF OPERATING WITH CONSISTENTLY HIGH EFFICIENCY. THE BURNER
SHALL BE EQUIPPED WITH A COMBUSTION FAN FOR QUIET AND ECONOMICAL OPERATION.
VENT AS PER MANUFACTURERS INSTRUCTIONS. REFER TO DRAWING M-2 FOR BOILER
SCHEDULE AND SPECIFIED PRODUCT. ALTERNATIVE PRODUCTS TO BE CONSIDERED.
PUMPS
CIRCULATION PUMP SHALL BE RATED TO A MAXIMUM WORKING PRESSURE OF 140PSI AND
TEMPERATURE OF 230°F.CIRCULATING PUMP SHALLL BE CONSTRUCTED WITH CAST IRON
BODIES. STANDARD SHAFT OFFERING SHALL BE CONSTRCUTED OF HIGH QUALITY,
HARDENED STAINLESS STEEL. CHECK VALVE SHALL BE RATED TO A MAXIMUM
TEMPERATURE OF 261° AND IS FIELD INSATALLABLE. ROTOR ASSEMBLY TO BE FACTORY
BALANCED. THREE SPEED PUMPS SHALL HAVE A MANUALLY ADJUSTABLE SPEED SWITCH,
INTEGRAL WITH THE PUMP. REFER TO PUMP SCHEDULE ON DRAWING M-2 FOR FURTHER
DETAILS AND SPECIFIED PRODUCT. ALTERNATIVE PRODUCTS TO BE CONSIDERED.
EXPANSION TANK
EXPANSION TANK TO BE BLADDER TYPE. WELDED CONSTRUCTION ABLE TO WITHSTAND
HIGH PRESSURE. TANK TO BE COMPATIBLE WITH WATER/GLYCOL MIXTURE UP TO 50%.
REFER TO EXPANSION TANK SCHEDULE ON DRAWING M-2 FOR FURTHER DETAILS AND
SPECIFIED PRODUCT. ALTERNATIVE PRODUCT TO BE CONSIDERED.
DESTRATIFICATION FAN
DESTRATIFICATION FAN TO COME WITH STATOR, MOTOR AND HOUSING. FAN TO COME WITH
WALL MOUNTED VARIABLE SPEED CONTROLLER. FAN MOST CONFORM TO UL 507 AND BE ETL
LISTED. ELECTRICAL REQUIREMENTS: 120V/1ɸ/60HZ.
SPECIFIED PRODUCT: AIRIUS PEAR 10-SP DESTRATIFICATION FAN
M-3
MECHANICALSPECIFICATION
Mills Phase Three
Tel. 613-592-1677
M.E.
DEC 14/17T.V.
AS SHOWN
411 Country Street
ARCH D - 24"X36"
ALMONTE, ONTARIO
IN CONSIDERATION OF THE RECEIPT OF THIS DOCUMENT,THE RECIPIENT AGREES NOT TO REPRODUCE, COPY, USEOR TRANSMIT THIS DOCUMENT AND/OR THEINFORMATION THERIN CONTAINED, IN WHOLE OR INPART, OR TO SUFFER SUCH ACTION BY OTHERS, FOR ANYPURPOSE, EXCEPT WITH THE WRITTEN PERMISSION OF TTFENGINEERING AND FURTHER AGREES TO SURRENDERSAME TO TTF ENGINEERING UPON DEMAND.