Replacement Parts List No. 700008400Revision W 10/2018
McQuay
Maverick II™ Commercial Packaged Rooftop
Cooling and HeatingMPS
030, 035, 040, 050Vintage A, E
To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 2
Contents
Parts List Revision History ............................................................................................................................. 3Serial Number Nomenclature ......................................................................................................................... 4Unit Model Nomenclature ............................................................................................................................... 5Electrical Legend ............................................................................................................................................ 6Compressor and Condenser Section Compressor and Condenser Section Diagrams .................................................................................... 7, 8 Components .............................................................................................................................................. 9Tubing Liquid Line Diagrams .......................................................................................................................... 10- 12 Discharge Line Diagrams ................................................................................................................... 13, 14 Suction Line Diagrams ....................................................................................................................... 15- 17 Optional Hot Gas Bypass Diagrams ................................................................................................... 18- 20 Components ............................................................................................................................................. 21Condenser Fan and Exhaust Fan .......................................................................................................... 22, 23Supply Air Fan Section Supply Air Fan Section Diagram .............................................................................................................. 24 Components ............................................................................................................................................. 25 Supply Air Fan Drive Components ..................................................................................................... 26, 27Evaporator Coil and Filter Section ......................................................................................................... 28, 29Economizer Section ................................................................................................................................ 30, 31Heat Section Gas Heat Section Diagrams .................................................................................................................... 32 Staged Gas Heat Components: Code 03= G AND Code 14= ***2, ***4 ............................................ 33, 34 Modulating Gas Heat Components: Code 03= G AND Code 14= ****M ............................................. 35, 36 Electric Heat Components ........................................................................................................................ 37 Hot Water Heat Section ...................................................................................................................... 38, 39Cabinet Base and Deck Diagram .......................................................................................................................... 40 Cabinet Component Diagrams ................................................................................................................ 41 Cabinet Components ............................................................................................................................... 42Controls Control Box Diagram ................................................................................................................................ 43 Common Control Components ................................................................................................................. 44 Disconnect Switch and Power Block ........................................................................................................ 45 Transformers and Fuses ........................................................................................................................... 46 Compressor Motor Protectors and Contactors ......................................................................................... 47 Condenser Fan Motor and Exhaust Fan Motor ........................................................................................ 48 Constant Air Volume: Code 05= C ........................................................................................................... 49 Variable Air Volume: Code 05= V .............................................................................................................. 50 Ground Fault Circuit Interrupter ................................................................................................................ 51 Powered Outlet Option ............................................................................................................................. 51
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 3
Parts List Revision History Revision Date Description New 04/07 New A 04/08 Added information for the following options: 575V, Hot Gas Bypass, Smoke Detector, Ball Valves, 0-30% Damper, Electric Heat, 575V VFDs, Ground Fault Circuit Interrupter and Line Reactors. Added Ref. #s and internal links between drawings and text. Updated drawings. Page 11: Corrected part number for Rollout Switch (was 113110701). B 05/08 Page 12: Added information on Modulating Gas Heat option. C 06/08 Page 11: Added part numbers and descriptions for Mist Eliminator Filter Kits. Page 12: Moved Ignition Control under the Standard Gas Heat heading. D 02/09 Page 13: Added Hot Water Heat Chart. Page 14: Inserted a new page and moved Ground Fault Circuit Interrupter from page 13 to 14. Page 38: Changed heading from Drawing: Heat Section to Drawing: Gas and Electric Heat. Page 39: Inserted a new page, added Drawing: Hot Water Heat. E 04/09 Page 6: Changed Low Pressure Switch p/n from 047356103 to 300045868. Changed High Pressure Switch p/n from 111050001 to 300045869. F 4/09 Updated the RPL vintage from “A” to “A, E”. (Vintage B- D reserved for MPS I.) Page 5: Code 02 Unit size add vintage “E”. G 4/09 Page 13: Added “Powered Outlet Option” chart. H 6/09 Page 18: Add Disconnect Kits and CO2 Kits. Page 19: Add “Cabinet Components” chart from page 18. I 6/10 Updated Cover and Revision page with current design logo. Page 7: Removed Condenser Coil Repair kit p/n per Tech Support instructions. J 12/11 Converted form to current software and corrected Misc. formatting issues. Page 15: Changed SPS1 p/n 049545013 to 910124528 & SPS2 p/n 049545012 to 910124529. Page 18: Changed CO2 sensor kit p/n 47-42565-02 to CO2 Duct Sensor 910111672 & CO2 Space Sensor, Wall Mount 107287012 per McQuay Tools. K 9/12 Rewrote and reorganized form to conform to current format. Repaginated form and updated TOC. Cover, Rev pg.: Updated to Daikin McQuay logo format. Various: Changed “McQuay Parts” to “Daikin McQuay Parts”. Page 5: Updated Unit Model Nomenclature to Rev. 01/09/12. Page 6 (NEW): Added page for Electrical Legend. Page 26, 27 (NEW): Added Drive tables from form 7000160 Rev. I pg. 26 & 27. Page 40- 48 (NEW): Updated Control Box section with new drawing and reorganized, updated, and added to component tables. Used info from form 7000160 Rev. I. L 12/12 Page 9: Reversed C180/C190 p/ns. Correct dims: 113141401= (45.92 x 86) and 113141501= (22.54 x 86). M 01/13 Page 9, 44: Updated and clarified Compressor Unit size table. Updated footnote #1. Page 43: Changed T2 Transformer p/n from “349937302” to “349937303”. N 09/13 Page 9: Changed Ref. # C180, 190 for size 050 from “113141501” to “113141401”. O 11/13 Cover, Rev. pg.: Updated to Daikin Applied logo format. Various: Changed “McQuay” and “Daikin McQuay Parts” to “Daikin Applied”. Page 5: Corrected Code 11 digit descriptions. Page 9: Rewrote Footnote #1. Page 25: Updated Spring colors and ratings. Page 41: Corrected MCB code information. Page 43: Corrected “Units without Gas Heat” code description. P 08/14 Page 5: Added “(Replaced w/ steel Pan)” to Code 09. Page 28: Added updated dwg. for new Drain Pan design. Added dwg. headers. Updated Page Header. Page 29: Changed Ref #E130 Drain Pan from “113087101” to “P500308201”. Deleted Ref # E140 and N/S Seal p/ns. Added footnote #1. Q 09/15 Cover: Updated to Daikin Legacy format. Page 9: Rewrote footnote #1. Page 22: Updated dwg. & added Bub descriptions. Page 23: Updated p/n table. Added footnote #1. Page 24: Updated dwg. Page 28: Updated obsolete molded Drain Pan dwg. Page 29: Updated E130 p/n description. Added E139- E140A p/ns. Added/rewrote footnotes. Page 33: Moved Modulating Heater components to new pg. 35. Updated p/ns and added Std. Heater dwgs. Rewrote/added footnotes. Page 34- 36 (NEW): Added pgs. w/ additional Heater dwgs. & components. Repaginated form & updated the TOC. R 07/16 Page 29: Updated E001 Evap. Coil p/ns per Engineering. S 11/17 Various: Changed “Standard Gas Heat” to “Staged Gas Heat”. Page 5: Misc. updates. Page 6: Reformatted table. Page 23: Updated Condenser Fan Mtr. p/n & rewrote/added footnotes. Page 28: Rewrote dwg. header. Page 33- 36: Added footnote re. LP Conv. Kits as needed. Misc. updates/corrections. Page 37: Added L150 High Limit p/n to table. T 12/17 Various: Misc. formatting fixes. Deleted green box note. Rewrote Heat Section pg. headers. Page 23: Rewrote footnote # 2. Page 37: Deleted footnote # 1. Page 39: Changed “Electrofin Coated” to “Coated”. Page 43: Rewrote footnote. U 04/18 Page 34- 36: Deleted N/S Heater Drain Pan. V 04/18 Page 33- 36: Added Flame Sensor Lead p/n. Page 51: Rewrote footnote # 1. W 10/18 Various: Rewrote footnote re. contacting DAA. Page 27: Changed p/n “049022620” to “049026620”.
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 4
FBO U 07 05 04800
Plant IdentificationFBO = Faribault, MN
Year of Manufacture07= 200708= 200809= 200910= 2010
etc.
U= Unit
Serial Number (build sequence)
Month of Manufacture01= January02= February03= March04= April05= May06= June 07= July08= August09= September10= October11= November12= December
Serial Number Nomenclature
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 5
01 MPS (Daikin Applied Packaged System)
02 Unit Size / Vintage 030A= 30 Ton 030E= 30 Ton 035A= 35 Ton 035E= 35 Ton 040A= 40 Ton 040E= 40 Ton 050A= 50 Ton 050E= 50 Ton
03 Heat G= Natural Gas Heat E= Electric Heat W= Water Heat Y= None
04 Voltage/Power Connection Digit 1 2= 208 Volt Power Supply 3= 230 Volt Power Supply 4= 460 Volt Power Supply 5= 575 Volt Power Supply Digit 2 P= Power Block D= Non-Fused Disconnect Switch
09 Coil Section S= Stainless Steel Drain Pan Y= Polymer Drain Pan (Replaced w/ steel Pan)
10 Cabinet D= Double Wall Construction
11 Supply Fan Motor Digits 1, 2 02= 2 HP 15= 15 HP 03= 3 HP 20= 20 HP 05= 5 HP 25= 25 HP 07= 7.5 HP 30= 30 HP 10= 10 HP Digit 3 P= Premium Efficiency 12 Supply Fan RPM 0000= Fan RPM (eg. 1525= 1525 RPM)
14 Heat Exchanger/Electric Heat/HW Heat Digits 1-3, for Gas, Electric Heat; 1- 4 for HW Heat 030= 300 MBH Gas Heat 040= 400 MBH Gas Heat 042= 420 MBH Gas Heat 060= 600 MBH Gas Heat 080= 800 MBH Gas Heat 054= 54 kW Electric Heat 072= 72 kW Electric Heat 090= 90 kW Electric Heat 108= 108 kW Electric Heat W121= 030, 035 Low HW Heat W102= 030, 035 High HW Heat W111= 040, 050 Low HW Heat W132= 040, 050 High HW Heat YYY= No Heat Digit 4 for Gas, Electric Heat G= Aluminized Heat Exchanger-Gas Heat S= Stainless Steel Heat Exchanger-Gas Heat Y= Electric Heat or No Heat Digit 5 for ALL 2= 2-Stage Gas Heat 4= 4-Stage Gas OR Electric Heat M= Modulating Gas Heat Y= No Heat OR No Valve Package for HW Heat
Unit Model NomenclatureMPS 030A Y 4D V 1DY RY DY Y D 07P 1525 FS YYYY YYYY Y Y Y Y Y Y 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21Code
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 6
Electrical Legend
ACT3 Actuator Motor, Economizer AHL Auxiliary Hi-Limit Switch, Gas Heat, Manual Reset CB10 Circuit Breaker, Supply Fan CB51 Circuit Breaker, Exhaust Fan(s} CCH1· 4 Crankcase Heaters DAT Temperature Sensor, Discharge Air DHL Duct Hi-Limit, Switch DS1 Disconnect Switch F1A, B Fuses, Control Circuit Transformer (T1), Primary F1C Fuse, Control Circuit Transformer (T1), Secondary HL Hi-Limit Switch, Gas Heat HP1, 2 Hi-Pressure Switches, Refrigeration Circuits LP1, 2 Low-Pressure Switches, Refrigeration Circuits M1- 4 Contactors, Compressors M10 Contactor, Supply Fan M11- 13 Contactors. Condenser Fans M51, 52 Contactors, Exhaust Fans MCB Microprocessor Circuit Board MJ Mechanical Jumper MMP1- 4 Manual Motor Protectors, Compressors MMP10 Manual Motor Protector, Supply Fan MMP11- 13 Manual Motor Protectors, Condenser Fans MMP51 Motor Protector, Exhaust Fans OAE Enthalpy Sensor, Outside Air OAT Temperature Sensor, Outside Air PB1 Power Block, Power Distribution PC5 Pressure Control, Dirty Filter Switch PC7 Pressure Control, Proof Airflow Switch R _HP1, 2 Relays, High Pressure Switch R _HTR1, 2 Relay, Heater stages 1 & 2 R _FANOP Relays, Fan Operation R _VFD10 Relay, VFD Enable, Supply Fan R _VFD51 Relay, VFD Enable, Exhaust Fans RAE Enthalpy Sensor, Return Air RAT Temperature Sensor, Return Air REC1 Receptacle, GFCI SPS1 Static Pressure Sensor, Duct SPS2 Static Pressure Sensor, Building T1 Transformer, Main Control (Line/115VAC) T2 Transformer, Control Input (115/24VAC) TB1 Terminal Block, Internal Distribution TB2 Terminal Block, Field TB51 Terminal Block, Exhaust Fan Distribution VFD10 Variable Frequency Drive, Supply Fan VFD51 Variable Frequency Drive, Exhaust Fans
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 7
Compressor and Condenser SectionCompressor and Condenser Section Diagram- Sizes 030, 035
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 8
Compressor and Condenser SectionCompressor and Condenser Section Diagram- Sizes 040, 050
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 9
Unit size Compressor #1 Compressor #2 Compressor #3 Compressor #4 Circuit 1 Circuit 2 Circuit 1 Circuit 2 030 10 HP 7.5 HP 7.5 HP - 035 10 HP 10 HP 7.5 HP - 040 10 HP 10 HP 10 HP - 050 10 HP 10 HP 10 HP 10 HP
Ref. # Description Part Number 030 035 040 050 C180 Condenser Coil, Standard, 45.92” x 86” (Ckt 1) 2 113118501 1 1 1 C190 Condenser Coil, Standard, 22.54” x 86” (Ckt 2) 2 113118601 1 1 1
NS= Not shown on diagram.1 The original motor is obsolete and no longer available. This inverter duty motor is a direct replacement.2 Some units originally used a 5 blade prop that is obsolete and no longer available. This 4 blade prop is the recommended
replacement for ALL fan props.
C410, C460, C510, C560H261, H271, H281
C414, C464, C514, C564H265, H275, H285
C418, C468, C518, C568H269, H279, H289
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 24
Supply Air Fan SectionDiagram
D22
0
D20
0
D14
0
D15
0
D16
0
D17
0
D19
5
40-5
0T O
NLY
POSI
TIO
N C
POSI
TIO
N D
D91
2F
D01
5
D13
0
D19
2D
182
D27
0
D25
0
D26
0
D24
0PO
SITI
ON
A
D00
5
D01
2
D11
0
D10
0D
120
40-5
0 TO
NO
NLY
30-3
5 TO
NO
NLY
30-3
5 TO
NO
NLY
D11
5
D11
0
D19
2D
193
POSI
TIO
N B
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 25
Ref. # Description Part Number D005 Fan Wheel, 24” (Sizes 030, 035) 300043659 D005 Fan Shaft, 1.4375 x 18.625 (used with 24” Fan Wheel) 300043661 D005 Fan Bearing, 1-7/16” (used with 24” Fan Wheel) 300043663
D005 Fan Wheel, 30” (Sizes 040, 050) 300043660 D005 Fan Shaft, 1.6875 x 21.50 (used with 30” Fan Wheel) 300043662 D005 Fan Bearing, 1-11/16” (used with 30” Fan Wheel) 300043664
1 Due to the large number of possible drive combinations, this list of drives is NOT complete. For RPMs not shown above, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
2 Quantity = 2.
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 27
Supply Air Fan SectionDrive Components 1
30 Inch Fan Sizes 040, 050 Motor Code 12 Motor Motor Fan Fan Belt HP Fan RPM Pulley Bushing Pulley Bushing 7.5 908 048419711 048416807 048419724 048416810 049261188 7.5 969 048419713 048416807 048419724 048416810 020243000 7.5 1029 048419715 048416807 048419724 048416810 020243000 7.5 1117 048419718 048416807 048419724 048416810 020243000 10 1007 048419804 048416707 048419820 048416907 049261114 2
1 Due to the large number of possible drive combinations, this list of drives is NOT complete. For RPMs not shown above, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
2 Quantity= 23 Quantity= 3
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 28
Evaporator Coil and Filter SectionDiagrams
M220
M280
E131
E131
E010
E130
E145
F040
F100
F020
F101
F010
E060
E001E055
E050
Stainless Steel Drain Pan E130 Assembly
F010
E060
F020
F030
E050
E020
E010
F040
E145
(OPTIONAL)
E140
E140A
E150
E015
E016
E051
(OPTIONAL)
E055
E001
F102
F101
F100
E146
E060 FOR 30, 35 & 50 TON ONLY(NOT USED ON 40 TON)
E147
E900
E139
E150
E139E140A
E140
E130
E130
E070
Original Design Molded Drain Pan (E130) & Nut and Seal Assembly (E140) shown for reference only
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 29
Evaporator Coil and Filter SectionComponents
Ref. # Description Part Number 030 035 040 050 E001 Evaporator Coil, 4-Row, 44 x 83, Std. 500344401 1 E001 Evaporator Coil, 4-Row, 44 x 83, Std. 500385001 1 E001 Evaporator Coil, 4-Row, 50 x 83, Std. 500394701 1 E001 Evaporator Coil, 4-Row, 62 x 83, Std. 500364101 1
NS Expansion Valve, 12.5 Ton (Circuit 2) 113101601 1 NS Expansion Valve, 15 Ton (Circuit 2) 113101701 1 1 NS Expansion Valve, 25 Ton (Circuit 2) 113101901 1 F100 Air Filter, 30% Pleated, 24 x 24 x 2 111046101 4 4 4 F101 Air Filter, 30% Pleated, 24 x 24 x 2 111046101 4 4 4 F100 Air Filter, 30% Pleated, 18 x 24 x 2 113105001 4 F101 Air Filter, 30% Pleated, 18 x 24 x 2 113105001 4 F102 Air Filter, 30% Pleated, 18 x 24 x 2 113105001 4 4NS= Not shown on diagram.1 Note that the original molded Polymer Drain Pan is obsolete and no longer available. Use p/n P500308201 as a stainless steel replacement.
2 Used on original MOLDED DRAIN PAN assembly ONLY.
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 30
Economizer SectionDiagrams
RA
Tem
pera
ture
Sen
sor
Opt
iona
l RA
Ent
halp
y S
enso
rVi
ew fr
om in
side
of u
nit
Opt
iona
l Sm
oke
Det
ecto
r
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 31
Ref. # Description Part Number H010 Economizer Damper Assy, 48” x 89.5” Unit Sizes 030/035 113078200 H010 Economizer Damper Assy, 74.75” x 89.5” Unit Sizes 040/050 113079000 H010 0-30% Damper Assy Unit Sizes 030/035 113127401 H010 0-30% Damper Assy Unit Sizes 040/050 113127501
H045 Mist Eliminator Filter Kit Unit Sizes 030/035 113128701 1
H045 Mist Eliminator Filter Kit Unit Sizes 040/050 113128801 2
H250 OAE-Enthalpy Control 113103601 - RAE-Enthalpy Control 113103701
NS Screw, Crimptite 059983001 NS Fan Guard, 26” 098668302
Economizer SectionComponents
NS= Not shown on diagram.1 Kit includes the following filters: (Qty. 1) 24x12x1 and (Qty. 4) 24x20x12 Kit includes the following filters: (Qty. 2) 18x12x1 and (Qty. 8) 18x20x1
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 32
Heat SectionGas Heat Section Diagrams
ELEC
TRIC
HEA
T O
PTIO
N
HIG
H L
IMIT
SW
ITC
H L
155
MO
UN
TIN
G P
OSI
TIO
N2
GAS
HEA
TER
OPT
ION
1 G
AS H
EATE
R O
PTIO
N
NO
HEA
T O
PTIO
N
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 33
Heat SectionStaged Gas Heat Components (Code 03= G AND Code 14= 300*2, 600*4)
Ref. # Description Part Number Qty. Staged Gas Heat L010 Gas Heater, Aluminized Steel, 300 MBH (Code 14= ***G*) 113084401 1 Gas Heater, Stainless Steel, 300 MBH (Code 14= ***S*) 113084402 1
L150 Auxiliary Limit Switch, Gas Heat 113110801 1 L155 High Limit Switch, 5”, Gas Heat 113110901 1 2
High Limit Switch, 7”, Gas Heat 113110902 1 2
Natural Gas to LP (Propane) Conversion Kits N/S LP Conversion Kit, 300 MBH 300043815K 3
N/S LP Conversion Kit, 600 MBH 300043817K 3
N/S= Not shown on diagram.1 L011 is used only when Code 14= 060*4.2 Note that either the 5” OR the 7” High Limit Switch could be installed. Confirm which switch is installed or contact Daikin
Applied with model and serial number information so that the correct switch can be identified.3 LP Conversion kits are ONLY available for Staged Gas Heat Furnaces (Code 14= ****2 OR ****4). The above listed
kits CANNOT be used on Modulating Gas Furnaces (Code 14= ****M). If a conversion from natural gas to propane is desired AND the unit has a Modulating Gas Heat Exchanger (L010), a NEW STAGED Heat Exchanger AND the correct LP Conversion Kit is required. Contact Daikin Applied to identify any additional parts required for the conversion.
01 02 08 1012
03
04
07
14 13 0506
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 34
Ref. # Description Part Number Qty. Staged Gas Heat L010 Gas Heater, Aluminized Steel, 400 MBH (Code 14= ***G*) 113084501 1 Gas Heater, Stainless Steel, 400 MBH (Code 14= ***S*) 113084502 1
L150 Auxiliary Limit Switch, Gas Heat 113110801 1 L155 High Limit Switch, 5”, Gas Heat 113110901 1 2
High Limit Switch, 7”, Gas Heat 113110902 1 2
Natural Gas to LP (Propane) Conversion Kits N/S LP Conversion Kit, 400 MBH 300043816K 4
N/S LP Conversion Kit, 800 MBH 300043818K 4
N/S= Not shown on diagram.1 L011 is used only when Code 14= 080*4.2 Note that either the 5” OR the 7” High Limit Switch could be installed. Confirm which switch is installed or contact Daikin
Applied with model and serial number information so that the correct switch can be identified.3 Quantity= 6pc. for Low Gas heat units and 12pc. for High Gas Heat units.4 LP Conversion kits are ONLY available for Staged Gas Heat Furnaces (Code 14= ****2 OR ****4). The above listed kits
CANNOT be used on Modulating Gas Furnaces (Code 14= ****M). If a conversion from natural gas to propane is desired AND the unit has a Modulating Gas Heat Exchanger (L010), a NEW STAGED Heat Exchanger AND the correct LP Conversion Kit is required. Contact Daikin Applied to identify any additional parts required for the conversion.
Heat SectionStaged Gas Heat Components (Code 03= G AND Code 14= 400*2, 800*4)
01 02 09 1012
03
04
07
1413 05
06
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 35
Heat SectionModulating Gas Heat Components
(Code 03= G AND Code 14= 300SM, 600SM)
(Modulating Heater shown)
Ref. # Description Part Number Qty. Modulating Gas Heat 5
L010 Modulating Gas Htr, St. Stl., 300 MBH 113084403 1 01 Motor, Draft Inducer, 115V, 2 Speed 300049614 1 03 Circuit Board, Direct Spark Ignition Control (DSI) 113142301 1 06 Switch, Air Pressure Control- 2 Stage 300051594 1 07 Gas Valve, Modulating 300049297 1 13 Circuit Board, 5:1 Modulating (VBC) 300049293 1
Staged Gas Heat 5
L011 Staged Gas Htr, St. Stl., 300 MBH (Code 14= 060SM) 113084402 1 1
01 Motor, Draft Inducer, 115V, 2 Speed 300049614 1 03 Ignition Control, Direct Spark Ignition (DSI) 300043668 1 06 Switch, Air Pressure Control 300043671 1 07 Gas Valve, 2 stage 300043672 1
L150 Auxiliary Limit Switch, Gas Heat 113110801 1 L155 High Limit Switch, 5”, Gas Heat 113110901 1 4
L155 High Limit Switch, 7”, Gas Heat 113110902 1 4
N/S= Not shown on diagram.1 L011 is used only with High Gas Heat (Code 14= 060SM) AND note that 113084402 is NOT a Modulating Heater. Use p/ns
from the STAGED and/or ALL GAS HEAT lists only. 2 Quantity= 2pc. for Modulating Gas Heaters and 1pc. for Staged Gas Heaters.3 Quantity= 6pc. for Low Gas heat units and 12pc. for High Gas Heat units.4 Note that either the 5” OR the 7” High Limit Switch could be installed. Confirm which switch is installed or contact Daikin
Applied with model and serial number information so that the correct switch can be identified.5 LP Conversion kits are ONLY available for Staged Gas Heat Furnaces (Code 14= ****2 OR ****4). If a conversion from natural
gas to propane is desired AND the unit has a Modulating Gas Heat Exchanger (L010), a NEW STAGED Heat Exchanger AND the correct LP Conversion Kit is required. Contact Daikin Applied to identify any additional parts required for the conversion.
01 02 08 09
10
13
04
07
11
03
0506
01 02 08 0910
03
04
07
14 11 0506
(StagedHeater shown)
14
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 36
(Modulating Heater shown)
(StagedHeater shown)
Ref. # Description Part Number Qty. Modulating Gas Heat 5
L010 Modulating Gas Htr, St. Stl., 400 MBH 113084503 1 01 Motor, Draft Inducer, 115V, 2 Speed 300049615 1 03 Circuit Board, 5:1 Modulating (VBC) 300049293 1 06 Switch, Air Pressure Control- 2 Stage 300051594 1 07 Gas Valve, Modulating 300049297 1 13 Circuit Board, Direct Spark Ignition Control (DSI) 113142301 1
Staged Gas Heat 5
L011 Staged Gas Htr, St. Stl., 400 MBH (Code 14= 080SM) 113084502 1 1
01 Motor, Draft Inducer, 115V, 2 Speed 300049616 1 03 Ignition Control, Direct Spark Ignition (DSI) 300043668 1 06 Switch, Air Pressure Control 300043671 1 07 Gas Valve, 2 stage 300043672 1
12 Rollout Switch 113118701 1 L150 Auxiliary Limit Switch, Gas Heat 113110801 1 L155 High Limit Switch, 5”, Gas Heat 113110901 1 4
L155 High Limit Switch, 7”, Gas Heat 113110902 1 4
Heat SectionModulating Gas Heat Components
(Code 03= G AND Code 14= 400SM, 800SM)
01 02 08 09
12
03
04
07
13
11 0506
01 02 08 09
12
03
04
07
1105
06
N/S= Not shown on diagram.1 L011 is used only with High Gas Heat (Code 14= 060SM) AND note that 113084502 is NOT a Modulating Heater. Use p/ns from the STAGED and/or ALL GAS HEAT lists only. 2 Quantity= 2pc. for Modulating Gas Heaters and 1pc. for Staged Gas Heaters.3 Quantity= 6pc. for Low Gas heat units and 12pc. for High Gas Heat units.4 Note that either the 5” OR the 7” High Limit Switch could be installed. Confirm which switch is installed or contact Daikin
Applied with model and serial number information so that the correct switch can be identified.5 LP Conversion kits are ONLY available for Staged Gas Heat Furnaces (Code 14= ****2, ****4). If a conversion from natural gas to
propane is desired AND the unit has a Modulating Gas Heat Exchanger (L010), a NEW STAGED Heat Exchanger AND the correct LP Conversion Kit is required. Contact Daikin Applied to identify any additional parts required for the conversion.
10
10
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 37
Sizes 040, 050 L012 Electric Heat Assy, 72 kW 113084637 113084638 113084639 113084640 L012 Electric Heat Assy, 90 kW 113084650 113084651 113084652 113084653 L012 Electric Heat Assy, 108 kW NA NA 113084773 113084774
ALL Sizes L155 High Limit Switch, Electric Heat 113110902 113110902 113110902 113110902
Heat SectionElectric Heat Components
NA = Not Available.
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 38
Heat SectionHot Water Heat Diagram
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 39
Ref. # Description Standard Coated Sizes 030, 035 Ton L200 Hot Water Coil, 42 x 66” 402817001 402817002 L200 Hot Water Coil, 42 x 66” 402817201 402817202
Sizes 040, 050 Ton L200 Hot Water Coil, 42 x 66” 402817101 402817102 L200 Hot Water Coil, 42 x 66” 402817301 402817302
Heat SectionHot Water Heat Components
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 40
CabinetBase and Deck Diagram
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 41
CabinetCabinet Component Diagrams
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 42
CabinetCabinet Components
Ref. # Description Part Number NS Insulation, 1.0” thickness 001168400 NS Gasket, Z-Channel, .125” x .750” 113107101 C905 Gasket, Door, .50” x .312” 113107201 B900 Gasket, Base Rail, .125” x 1.50” 113107001 NS Gasket, Supply Air Fan, .125” x 3.50” 113080401 NS Hinge, 2” x 1” 032457700 M930 Panel Latch Assy 113087201 M935 Latch Handle, Pulltab 113087801 NS Screw, Crimptite 059983001 NS Screw, for Hinge 038990703 NS= Not shown on diagram.
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 43
ControlsControl Box Diagram 1
1 This diagram is representative of a typical control box layout. Not all possible Control Box configurations are shown above as components and component layout vary depending upon unit options selected.
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 44
Ref. # Description Part Number No Heat: (Code 03= Y) OR Hot Water Heat: (Code 03= W) MicroTech II PCO3 Controller, Medium 349953211 1, 2
4 Stage Electric Heat: (Code 03= E) AND (Code 14= ****4) MicroTech II PCO3 Controller, Large 349953311 1
Gas Heat/Low Heat: (Code 03= G) AND (Code 14= 030**, 040**) MicroTech II PCO3 Controller, Medium 349953211 1, 2
Gas Heat/High Heat: (Code 03= G) AND (Code 14= 060**, 080**) MicroTech II PCO3 Controller, Large 349953311 1
NS CO2 Duct Sensor 910111672 NS CO2 Duct Sensor Pitot Tube only 300049931 NS CO2 Space Sensor, Wall Mount 107287012 NS Space Sensor, Wall Mount 113117701 NS Space Sensor w/ Tenant Override, Wall Mount 113117801 RAT Temperature Sensor, Return Air, 30 ft. 073007303 DAT Temperature Sensor, Discharge Air, 30 ft. 073007303 OAT Temperature Sensor, Outside Air, 30 ft. 073007303
PC5 Switch, Dirty Filter 349956812 PC7 Switch, Proof of Airflow 349956811 DHL Switch, Duct High Limit 349956813
NS= Not shown on diagram.1 The Main Control Board must be programmed in order to function correctly. When ordering a replacement MCB, providethe unit model and serial number so the unit specific software code can be loaded before shipment.2 This controller is obsolete with limited availability. Check for availability BEFORE ordering. Use 349953311 as a
substitute.3 This Communication Module Kit contains the Communication Module and Installation Instructions.
MCB
COM
Relay, SPDT, 120VAC, 15A 349934741
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 45
Ref. Description Part Number Disconnect Switch 1 (Code 04= *D) DS1 Circuit Breaker Kit, 100A (includes Switch, Mechanism and Handle) 500235201 Circuit Breaker, 100A, Molded Case Switch 349935125 Flange Mounted Operating Mechanism and Handle 349958201 Disconnect Shaft 349953801 GFI Lug Kit (Code 20= F) 349926501 Load Lugs, 6-position 349956101
DS1 Circuit Breaker Kit, 400A (includes Switch, Mechanism and Handle) 500235501 Circuit Breaker, 400A, Molded Case Switch 349935325 Flange Mounted Operating Mechanism and Handle 349958401 Disconnect Shaft 349953802 GFI Lug Kit (Code 20= F) 349926601 GFI Connector (Code 20= F) 193404101 Load Lugs, 12-position 349956401 Power Block 1 (Code 04= *P) PB1 Power Terminal Block, 175A, 3P, 2 x 12, 600V 030372775 PB1 Power Terminal Block, 350A, 3P, 2 x 6, 600V 030372781 PB1 Power Terminal Block, 420A, 3P, 1 x 8, 600V 030372783 PB1 Power Terminal Block, 510A, 3P, 2 x 12, 600V 030372786
Controls Disconnect Switch and Power Block
1 This list includes the most common components offered. Due to the various unit options available, before ordering it is necessary to confirm what amperage Circuit Breaker is installed in the unit, or if this is not known, use the Distributor Tools BOM Search function on the Daikin Parts website or contact Daikin Applied with model and serial number information to ensure that the correct part(s) are identified.
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 46
Unit size Compressor #1 Compressor #2 Compressor #3 Compressor #4 Circuit 1 Circuit 2 Circuit 1 Circuit 2 030 10 HP 7.5 HP 7.5 HP - 035 10 HP 10 HP 7.5 HP - 040 10 HP 10 HP 10 HP - 050 10 HP 10 HP 10 HP 10 HP
Maverick II Rooftop, MPS 030 - 050, Vintage A, E Rev. W 10/18 RPL 7000084 / Page 48
1 Note: Components listed above are replacements for a factory installed unit powered GCFI (Code 20= F). If planning to ADD this option in the field, contact Daikin Applied with the unit GO and Serial Number to identify any additional components required.
Ref. # Description Part Number
N/S Contactor, 35A, 600V 349932521 N/S Contactor, 50A, 600V 349932522 N/S Fuse, 60A, 600V 071203502 N/S Pressure Differential Switch, 15A, 277V 300046058 N/S Transformer, 75VA, 230V, 24V 300046059 N/S Transformer, 75VA, 460V, 24V 300046060 N/S Transformer, 75VA, 575V, 24V 067111901 N/S Transformer, 150VA, 230V, 24V 300046061 N/S Power Block, 50A, 3 Pole 300046062 N/S Power Block, 125A, 3 Pole 300046063 N/S Power Block, 215A, 3 Pole 300046064 N/S Power Block, 260A, 3 Pole 300046065 N/S Power Block, 325A, 3 Pole 300046066