Air Permeability as per EN 1026 PRESSURE in Pascals FLOW TIME 100 lt. of air in sec. Hermetic sliding door for clean rooms 50 100 150 200 250 300 1,2 3,0 4,2 4,8 6,0 6,6 0,44 1,09 1,53 1,75 2,19 2,40 300,00 120,00 85,71 75,00 60,00 54,55 0,17 0,44 0,61 0,70 0,87 0,96 Classification as per EN12207 is: CLASS 4 Air Permeability Pressure in Pascals No classification Class 1 Class 2 Class 4 m3 / h x m 2 of surface m 3 / (h x m) of joint 1 2 4 6 8 10 20 40 60 80 100 0,5 1 2 5 10 15 10 50 100 150 300 surface unit joint length Class 3 Hermetic sliding door for clean rooms Dimensions Technical specifications AIR FLOW LOST Total m3/h Surface unit m3/h x m2 Joint length m3/h x linear mt. MECHANICAL FEATURES BRAVO OPERATOR Bi-part BRAVO OPERATOR Single slide PERFORMANCE SAFETY ELECTRICAL FEATURES Opening speed per leaf. Adjustable Relative opening speed (bi-part). Adjustable Closing speed per leaf. Adjustable Closing force. Adjustable Acceleration Independent adjustment of speed and force Low voltage 73/23/CEE Electromagnetic Compatibility (EMC) 89/336/CEE (AS 4251.1) Construction products 89/106/CEE Safety of machinery 89/392/CEE - 91/368/CEE - 93/44/CEE Air Permeability Class 4 (EN12207) Operator standard dimensions Maximum operator length Maximum clear width Minimum clear width Maximum recommended clear height Maximum leaf weight Standard power supply Optional power supply No. and type of motors Inverter technology (exclusive of manusa) Direct drive transmission Power consumption during operation Fuse protection Environment temperature during operation Rechargeable fail-safe batteries Safety stop/reverse Infrared barriers YES – Adjustable 1 or 2 YES – Adjustable 1 or 2 224x180 mm 6000 mm 2950 mm 1300 mm 2300 mm 2x85 Kg 224x180 mm 4100 mm 1800 mm 650 mm 2300 mm 1x85 Kg 50 - 100 cm/s 100 – 200 cm/s 15 - 40 cm/s 40 N - 140 N 2 m/s2 YES 50 - 100 cm/s - - 15 - 40 cm/s 40 N - 140 N 2 m/s2 YES 230v 50-60Hz±15% 110v 50-60Hz±20% 2xAC Three-phase VV-VF Without reduction gear 265 W 4A -20ºC to 65ºC YES 230v 50-60Hz±15% 110v 50-60Hz±20% 2xAC Three-phase VV-VF Without reduction gear 265 W 4A -20ºC - 65ºC YES BRAVO OPERATOR Bi-part BRAVO OPERATOR Single slide BRAVO OPERATOR Single slide BRAVO OPERATOR Bi-part BRAVO OPERATOR Single slide APPLICABLE EUROPEAN STANDARD prEN 12650 Distributor: All pictures, texts and graphics are property of Manusa. Manusa reserves the right to modify in any moment and without previous advise the information and technical data displayed in this brochure. All information in this brochure must be used as a reference only and do not represent any contractual obligation. Vía augusta, 17-19, 2º 2ª 08006 Barcelona - Spain Phone. +34 93 218 37 37 Fax +34 93 218 56 10 manusa Automatic doors Polígono Industrial Km. 1,2 43800 Valls - Tarragona (Spain) Tel. +34 97 760 96 01 Fax +34 97 760 51 54 www.manusa.com OFFICE (EXPORT) FACTORY Hermetic sliding door for clean rooms manusa Specifically designed for use in clean rooms, the Manusa automatic door combines high volumes of traffic whilst ensuring the maximum levels of hermetic sealing. The range of doors offer the optimum choice for rooms where positive pressure is needed to ensure a clean environment, meeting the most demanding of requirements. The hermetic doors keep operating theatres or clean rooms hygienic and thermally efficient in order to comply with regulations, whilst providing maximum safety for the end user. The hermetic doors are appropriate for operating theatres, hospitals, laboratories, the chemical industry, food processing plants and any clean room environment. AUTOMATIC SLIDING DOOR FOR CLEAN ROOMS When hygiene is so important as safety. Maximum sealing and hygiene for clean rooms Sección Horizontal 40 CW (Clear Width) Elevation (bi-part) Vertical section Floor plan AT(Min)=(2xPL)+200 HL CW (Clear Width) INTERIOR EXTERIOR 20 23 AT(Min)=(2xPL)+200 ACM=500 AM=(AH/2)+40 Vertical Section Door in open position Door in closed position HT=HL+200 HM=HL+10 HCM=400 HL HM=HL+10 HCM=400 5 20 225 180 225 manusa 180 T(Min)=(2xPL)+150 INTERIOR Floor Plan EXTERIOR 20 23 CW (Clear Width) 40 AM=AH+80 CW (Clear Width) Vertical Section Elevation (single slide with right side opening) HL T(Min)=(2xPL)+15 180 Floor plan Vertical section