Top Banner
Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty Guide: Sarah Brownell Customer: Fermin Reyegadas, Fundacion Cantaro Azul
18

Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Aug 19, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Matt Switzer (ME)

Tyler Josselyn (ME)

Evan Hall (EE)

Phil Floroff (EE)

Faculty Guide: Sarah Brownell Customer: Fermin Reyegadas, Fundacion Cantaro Azul

Page 2: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Overview • Project background

• Planning

• System design

• Testing

• Conclusions

• Recommendations

• Questions

Page 3: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Project Background

• Existing UV water treatment system

• Gravity fed

• Weak local power grid

• Objective:

– Detect failure & protect clean water

Page 4: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Customer Needs • Prevent contamination of clean

tank during given failure modes: -Power outage -Brownout -Blown UV bulb • Warn kiosk operator of failure • Allow for independent UV

chamber operation • Made from materials available

in Mexico • Require few consumable parts • Maintain 5 L/min flow rate per

chamber • Low cost solution

Page 5: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Engineering Specs

Page 6: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

System Architecture

Control Board (PCB)

Irrigation Valve 1

Irrigation Valve 2

Water Flow Control

UV photodiode 1

UV photodiode 2

Failure Detection

Warning Speakers

LED System Indicators

Operator Interface

Page 7: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Valve Assembly

• Irrigation valves

• Solenoid/diaphragm

• Low flow, low pressure operation

• Fail Closed

• Easy integration

Dual irrigation valve assembly

Page 8: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Electronics

• The printed circuit board shown here controls the valves and warns the operator that there is a failure

• Requires some trained assembly (to be assembled by PCB assembly service)

Page 9: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Electronics Enclosure

• The PCB was designed to fit into a small conduit box that can be mounted in the kiosk, near the valves

• Speakers and LEDs are mounted externally on box

Page 10: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Photodiodes

• Capable of detecting all failure modes

• Design allows system prevents flow restart until safe level of UV output is reached

• No UV Chamber draining will be necessary

• Automatic restart after power loss

• Simple installation in chamber

Photodiode

UV Bulb

Page 11: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Warning the operator

• Failure – Speaker sounds and red LED lights, both powered by 9V battery

• To turn off the speaker and red LED, the operator can flip a switch

• Once the problem is fixed, a green LED will light, the switch is flipped back

• The system also includes an amber LED that turns on when the battery voltage is low

Speaker

System Ready Switch

Page 12: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Test Rig

• We built a test rig to simulate the gravity fed system in the actual kiosks

• The two irrigation valves run in parallel to two UV chambers

• We are able to simulate a power failure by pressing the red button seen to the left

Page 13: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Test Results

• Gravity fed system achieved a flow rate of 4.5 L/min

• Inlet/outlet height differential must be >4 ft.

• Circuit board closes valve when UV light is not present

• Speaker/LED gets attention of operator at > 8 meters

• Backup alarm/LED will run for 17 consecutive hours on one 9V battery

• Valves seep 15.5mL/hr average

Page 14: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Budget

MSD Costs Budgeted Actual

Test Stand (tanks, pump,

structure) $400 $184.39

Electrical (wire, circuits,

PCB) $100 $202.63

Plumbing (Pipe, flow stop

mechanism) $100 $63.10

Total $600 $450.12

Costs to Customer Quantity Total Price

Valves 2 $34.10

PCB 2 $66.00

Photodiodes 2 $44.88

LEDs 6 $1.96

Speakers 2 $4.58

Wiring As

Necessary ~$10.00

Assembly - Need Quote

Other Parts - $40.71

TOTAL per Kiosk $202.93

Page 15: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Conclusion: Successes • Independent chamber operation

– Using two independent circuits

• Under budget

• LEDs and speakers will get operator attention

• Valves stop water flow

• Auto-restart when safe UV output level sensed in chamber

Page 16: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Conclusion: Challenges • Valve leakage due to dirty diaphragm

• Mousetrap valve concept

• Getting system to work on one circuit

• Speakers not as loud as expected

• Couldn’t incorporate rapid power on-off delay • Deemed unnecessary

• Customer will not be able to fix electrical issues in field

• PCB assembly for customer

Page 17: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Recommendations

• 2 independent circuits

• Periodic diaphragm cleaning

• Test correlation between UV output and photodiode voltage

• Valves located close to UV chambers

• Upon install, ensure valve seals water flow

Page 18: Matt Switzer (ME) Tyler Josselyn (ME) Evan Hall (EE) Phil ...edge.rit.edu/edge/P12412/public/final_presentationpdf.pdf · Tyler Josselyn (ME) Evan Hall (EE) Phil Floroff (EE) Faculty

Questions?