Top Banner
Master Lighting Master Light Switch By INNCOM
4

Master Light Switch - Inncom by Honeywell · Master Light Switch to ensure that lights are always off in unoccupied rooms. Our lighting controls provide comfort, safety and convenience,

Aug 09, 2018

Download

Documents

lamdat
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Master Light Switch - Inncom by Honeywell · Master Light Switch to ensure that lights are always off in unoccupied rooms. Our lighting controls provide comfort, safety and convenience,

Master Lighting

Master Light SwitchBy INNCOM

Page 2: Master Light Switch - Inncom by Honeywell · Master Light Switch to ensure that lights are always off in unoccupied rooms. Our lighting controls provide comfort, safety and convenience,

When it comes to guestroom lighting control compliance with the IECC,

ADA and NEC codes, you could take the traditional, costly approach and

wire every lighting circuit to a switch and relay by the entry door. Even in a

modestly sized standard room, this could add as much as 200 extra feet of

conduit and wiring, as well as the labor necessary to wire the lamp plugs

to work with the entry master switch. Once in use, such a system has been

known to cause guest complaints because lights in the room won’t work

unless the entry switch is on. But it does not have to be that way!

The INNCOM® Occupancy-Based Master Light Switch automatically turns

off lighting in unoccupied rooms without ever inconveniencing the guest.

When the guest enters the room, the Master Light Switch illuminates a

welcome lighting scene; when the guest leaves, all lights turn off. Using

smart INNCOM switches and Lamp Control Modules, lighting can be

custom programmed to suit your room design. Additionally, the system is

engineered to ensure that light fixtures will work when an occupant wants

them to work, regardless of whether the master switch is in the on or

off position.

• Every switch or lamp can be programmed to suit your room design –

Superior guest functionality.

• The INNCOM master switch works effectively at the door without

adversely affecting guest comfort.

• Significant project cost reduction on the wiring, conduit and labor

needed as compared to traditional wiring.

• The INNCOM solution also enables the property to automatically

turn off lighting in un-occupied rooms – your contribution to a better

environment.

Contact INNCOM and let us help you with your installation design and

planning for all your guestroom control needs.

Hotel and Motel Guestroom Lighting -- hotel and motel guest rooms and guest suites shall have a master control device at the main room entry that controls all permanently installed luminaries and switched receptacles.

-- ASHRAE 90.1

“Sleeping units in hotels, motels, boarding houses or similar buildings shall have at least one master switch at the main entry door that controls all permanentlywired luminaires and switched receptacles, except those in the bathroom(s). Suites shall have a control meeting these requirements at the entry to each room.”

-- Section 505.2.3 IECC

Master Light Switch

Conventional Master Light Switch

Each switch leg is run back to the Master Switch

INNCOM Master Light SolutionMaster Switch communicates via

Low voltage cable or Radio Frequency

$

$

$

$

3 Way Switch Leg viaConduit and LineVoltage Cable

Cond

uit L

ine

Volta

ge C

able

RF Communication

Conduit Line Voltage Cable

Page 3: Master Light Switch - Inncom by Honeywell · Master Light Switch to ensure that lights are always off in unoccupied rooms. Our lighting controls provide comfort, safety and convenience,

Proposed measure requires:

• Mandatory installation of automatic controls for HVAC, and lighting, in

guest rooms

• Controls return HVAC equipment to a setback position and turn off

lighting when room is empty

Title 24 Guest Room Occupancy Controls California Statewide Utility Codes and Standards Program

Hotel/Motel Guest Room Occupancy Controls for HVAC and lighting

systems would require installation of occupancy controls for HVAC

equipment, and all lighting fixtures in hotel/motel guest rooms, including

plug in lighting. These occupancy controls can be captive card key

controls, or occupancy sensor based control.

Daylighting control requirements have also been vastly expanded. The new

code will require photocontrols in all interior day lit spaces with at least

120W of installed lighting power. This change in criteria, from sizeable

areas to modest lighting power use, significantly expands the number of

spaces required to use photocontrols, affecting virtually every office or

commercial space with skylights or windows.

Sample of a MODEVA Master Light Switch

Sample of a EVORA Master Light Switch

Specific Application controls C405.2.3

Hotel and motel sleeping units and guest suites:

• Master control device at main room entry controls all permanently

installed luminaires and switched receptacles

Hotel Lighting Specifications from the US Department of Energy

Page 4: Master Light Switch - Inncom by Honeywell · Master Light Switch to ensure that lights are always off in unoccupied rooms. Our lighting controls provide comfort, safety and convenience,

Master Light Sell | Rev2 | 12/16© 2016 Honeywell International Inc.

Honeywell 277 West Main Street

Niantic, CT 06357

+1.860.739.4468For more informationwww.inncom.com

INNCOM Lighting ControlHoneywell understands that guestroom lighting control is more than

just being able to turn lights on and off. Lighting control encompasses

everything from basic energy savings to creating memorable guest

experiences. Our environmentally friendly lighting systems comply with

energy-conservation building codes and can include an all on / off

Master Light Switch to ensure that lights are always off in unoccupied

rooms. Our lighting controls provide comfort, safety and convenience, too.

Automatic nightlights and entry welcome lights guide and assure guests

in an otherwise darkened room, while multi-point control makes it easy

for guests to adjust lighting from virtually anywhere in the guestroom.

Honeywell's INNCOM offerings give you design tools to create both the

visual interface (custom wall-mounted panels, tabletop touchscreens) and

the lighting experience (focused task lighting, ambient mood lighting). We

will also work with you to adapt your custom system to meet your unique

requirements

Elements Master Light switch with Privacy and Make-Up-Room request buttons