Synchronized Clock Systems The Sapling Company, Inc. 1633 Republic Road, Huntingdon Valley, Pennsylvania 19006 U.S.A Phone: +1.215.322.6063 Fax: +1.215.322.8498 Web: www.sapling-inc.com Master Clock Programmable Relays for Tone Generator SMA Series Master Clock Normally Open Common Relay 1 30 29 Tone Generator Power Amplifier Power Typical Installation when only one tone is being generated
2
Embed
Master Clock Programmable Relays For Tone Generator - V1 · Master Clock Programmable Relays for Tone Generator Sapling Master Clock is offered with either 4, 8, or no programmable
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
S y n c h r o n i z e d C l o c k S y s t e m s
The Sapling Company, Inc.1633 Republic Road, Huntingdon Valley, Pennsylvania 19006 U.S.A
Master Clock Programmable Relays for Tone Generator
Sapling Master Clock is offered with either 4, 8, or no programmable relays
Each programmable relay max load is up to 8 AMPS at 120VAC or 5 AMPS at 240VAC
If the current load is, or close to 5 AMPS (240VAC) or 8 AMPS (120VAC) it is better to distribute current consumption between more than one relay
If the load is greater than 5 AMPS (240VAC) or 8 AMPS (120VAC), use 2 relays or as needed
Drawings show a tone generator and amplifier. If a tone generator with a built-in amplifier is used, you do not need to purchase a separate amplifier as shown in the drawings. In this case, you can hook up the tone generator directly to the master clock
SMA Series Master Clock
Normally Open Common
Relay 1
30 29Tone
Generator Power
Amplifier Power
SMA Series Master Clock
Normally Open Common
Relay 2
33 32Tone
Generator Power
Amplifier Power
Typical Installation when more than one tone is being generated