Analytical Chemistry • Chromatography (Separations) Mass Spectrometry • Infrared (IR) Spectroscopy • Nuclear Magnetic Resonance (NMR) Spectroscopy • X-ray Crystallography (visual solid state molecular structure)
17

Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

Jun 18, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

Analytical Chemistry

• Chromatography (Separations)

• Mass Spectrometry

• Infrared (IR) Spectroscopy

• Nuclear Magnetic Resonance (NMR) Spectroscopy

• X-ray Crystallography (visual solid state molecular structure)

Page 2: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

What insights are we hoping to gain?

• Molecular Mass/Isotopic Distribution

• Molecular Formula

• Some Structural Characteristics – Fragmentation Pattern

Mass Spectrometry

Page 3: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

Only molecules of the correct m/z (mass/charge) will make it to the detector.

Mass Spectromeric Isotope Indentification

Page 4: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

EI-MS of 2,2-Dimethyl Pentane

Page 5: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

Molecular ("parent") ion

Fragment ("daughter") ions

Base peak (largest signal)

Peaks with smaller m/z values __ called fragment ion peaks __

represent positively charged fragments of the parent molecule

EI-MS of 2,2-Dimethyl Pentane

Page 6: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

Molecular iontert-butyl cation

(iso) propyl cation

Me Me

Me

methyl cation

ethyl cation

EI-MS of 2,2-Dimethyl Pentane

Page 7: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

60

31

42

EI-MS of n-Propanol

Page 8: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

EI-MS of 4-Heptanone

Page 9: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

C3H7

OH

(iso) propyl cation

Molecular Ion

acylium ion

• +

EI-MS of 4-Heptanone

Page 10: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

Molecular Ion

Why is there a signal higher than the Molecular ion?

EI-MS of 4-Heptanone

Page 11: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

Isotopes

Page 12: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

170 172

91

EI-MS of Benzyl Bromide

Page 13: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

Isotopes

Page 14: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

170 172

91

C7H779Br C7H7

81Br

Benzyl cation

EI-MS of Benzyl Bromide

Page 15: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

EI-MS of 4-Chloroanisole

Page 16: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

Isotopes

Page 17: Mass Spectrometry 1.pdf · 2008-02-05 · Mass Spectrometry. Only molecules of the correct m/z (mass/charge) will make it to the detector. Mass Spectromeric Isotope Indentification.

Isotopes