Masonry - Revision

March 2008

Page 2: Masonry Revision 2007 08

Vertically loaded masonry

Page 3: Masonry Revision 2007 08

Examples• Problem 1• An internal loadbearing masonry wall

has a clear vertical span of 2.5 m and supports a rigid continuous floor together with loads transferred from upper storeys.

• Unfactored vertical loads acting on this masonry are:

• Dead load - 127.5 kN/m• Imposed load - 15.0 kN/m• It is necessary to use a 190 mm high x

140 mm wide aggregate concrete block. What strength block, would be required to take the applied loads?

• Assume designation (iii) mortar is to be used.

• Assuming normal control of manufacture and construction m = 3.5

2500

mm

End conditions

Wall part of 4 storey building

Page 4: Masonry Revision 2007 08

Design loads (?)

• Dead load Gk = 127.5 kN/m• Imposed load Qk = 15.0 kN/m

• Design dead load = f Gk • = 1.4 x 127.5 = 179kN• Design imposed load• = f Qk = 1.6 x 15 = 24• TOTAL = 203 kN/m

Page 5: Masonry Revision 2007 08

Capacity reduction factor Depends on – slenderness ratio and eccentricity of load

• Slenderness ratio = effective height/effective thickness

• 24.3.2 Effective height. 24.3.2.1 Walls• Effective height of a wall :• a) 0.75 times the clear distance between lateral supports which provide

enhanced resistance to lateral movement; or• b) the clear distance between lateral supports which provide simple

resistance to lateral movement.

• Wall clamped in position - Enhanced restraint at top and bottom• Effective height = hef = 2.5 x 0.75 = 1.875 m• Effective thickness = Actual thickness • = tef = t = 0.14 m

OK 2 < 13.39 = 0.14

1.875 =

t

hRatioS

ef

ef 7

Page 6: Masonry Revision 2007 08
Page 7: Masonry Revision 2007 08

Capacity reduction factor Depends on – slenderness ratio and eccentricity of load

• Eccentricity of load.

• Internal wall with no eccentric loads, so eccentricity = 0.00mm

Page 8: Masonry Revision 2007 08

13.4 β = 0.90

Page 9: Masonry Revision 2007 08

Design vertical load capacity/unit length. (Clause 28.2.2)

• Aspect ratio of unit = 190/140 = 1.36

t

N = f or

f.t. = N m

km

k

mmN/ 5.64 =10 x 140 x 0.9

3.5 x 10 x 203 = f 2

3

3

k

Masonry characteristic strength is known.

What units are required?

Page 10: Masonry Revision 2007 08

Solid blocksAspect ratio = 1.36

fk = 5.64, designation (iii) mortar

Interpolate between tables

Inspect table and make a judgement

5.64

Select appropriate parts of table 2 , BS5628 : Part 1

Page 11: Masonry Revision 2007 08

Try blocks of strength 10.4N/mm2

• fk = 6.33N/mm2 ≥ 5.64N/mm2 so OK

)1.42.8)6.00.2

6.036.11

( x )(

)( + 4. = f k

Page 12: Masonry Revision 2007 08

Design example 2• Lower lift of a 4-storey cavity wall carries

factored total load of 130 kN/m. 25kN/m of this is applied at an eccentricity of t/6 to the inner leaf of the bottom lift. The remaining load from the floors above is applied axially to the same leaf.

• What strength of block is required? Calculate the vertical load capacity of this cavity wall.

• Assume• 90mm solid block outer skin• 140mm thick solid block inner skin.• 190mm high units used• 50mm cavity• Designation (iii) mortar m = 3.5 for • Normal (manufacturing /const.) control

End conditions

3000

mm

Lower lift of cavity wall

Page 13: Masonry Revision 2007 08

SolutionCapacity reduction factor

depends on ecc’n of applied load & slenderness ratio

• Eccentricity of 1st floor loading • ex = t/6 = 140/6 =23.3mm• BRE guidance – Lecture notes

• Ecc’n of Resultant total load. • Moments about wall centre

• 130x = 25 x 23.3• So x = 4.48mm = 0.03t• Less than 0.05 t (See Table 8).

23.3mm

105kN 25kN

xmm

Resultant 130kN

Page 14: Masonry Revision 2007 08

Slenderness ratio = effective height/ effective thickness = hef/tef

• Effective height :

• 24.3.2 Effective height. 24.3.2.1 Walls• a) 0.75 times clear dist between lateral supports

which provide enhanced resistance to lateral movement; or

• b) clear dist between lateral supports which provide simple resistance to lateral movement.

• Effective height = 0.75 x 3000 = 2250mm

• Effective thickness : • Greatest of • 2/3(t1 + t2) = 2/3(140 + 90) = 154mm• t1 = 140mm• t2 = 90mm

• Slenderness ratio = 2250/154.1 = 14.6

End conditions

3000

mm

Page 15: Masonry Revision 2007 08
Page 16: Masonry Revision 2007 08

14.6 β = 0.872

Page 17: Masonry Revision 2007 08

Design vertical load capacity/unit length. (Clause 28.2.2)

t

N = f or

f.t. = N m

km

k

mmN/ =10 x 140 x 0.

3.5 x 10 x = f 2

3

3

k 77.386

130

Page 18: Masonry Revision 2007 08

Solid blocksAspect ratio = 1.36

Select appropriate parts of table 2 , BS5628 : Part 1

Interpolate between tables

fk = 3.77,

Inspect table and make a judgement

designation (iii) mortar

3.77

Try a 5.2 N/mm2 unit

Page 19: Masonry Revision 2007 08

Try blocks of strength 5.2N/mm2

• Aspect ratio of unit = h/t = 190/140 = 1.36• Interpolating between Tables 2(c-d), BS 5628

• But 3.86 ≥ 3.73N/mm2 so OK• Use 5.2 N/mm2 unit in wall

2/86.3)5.20.5(6.02

6.036.15.2 mmNfk

kN f.t.

= NcapacityloadverticalActualm

k 3.13410005.3

86.314087.0

Page 20: Masonry Revision 2007 08

Laterally loaded masonry walls

Page 21: Masonry Revision 2007 08

Basic design example

H=L

L

Free edge

Simply supported

Determine the required thickness of a single leaf wall supported as shown above using the following criteria:

Page 22: Masonry Revision 2007 08

Basic design example• Characteristic wind load = 0.45 kN/m2

• Height of wall to free edge = 4.5 m• Length of wall between restraints= 4.5 m• Conc. blocks (solid) strength = 7.3 N/mm2

• Normal category const’n control• Category I or II units• Panel not providing stab. to struct.

γf = 1.2 [Clause 18(b)]• Ignore effects of self weight

γm = 3.0

[Table 4]

Page 23: Masonry Revision 2007 08

Basic design example - Flexural loading

• The design bending moment per unit height of the wall is given by the following expression (Clause 32.4.2).

L W = m 2fk

Page 24: Masonry Revision 2007 08

Basic design example - Flexural loading

• Bending moment coefficient () depends on– orthogonal ratio (fkb/fkp)

– aspect ratio h/L– support conditions

Page 25: Masonry Revision 2007 08

Basic design example - Orthogonal ratio - (fkb/fkp)

• Try a 7.3N/mm2 block, 190mm thick

• Determine [fkb and fkp] (Table 3)

• fkb for 100mm wide 7.3 N/mm2 = 0.25

• fkb for 250mm wide 7.3 N/mm2 = 0.15

• fkb for 190mm wide block, = 0.19

(by linear interpolation)

Page 26: Masonry Revision 2007 08

Basic design example - Orthogonal ratio

• fkp for 100mm wide 7.3 N/mm2 = 0.60

• fkp for 250mm wide 7.3 N/mm2 = 0.35

• fkp for 190mm wide block, = 0.45

(by linear interpolation)

Page 27: Masonry Revision 2007 08

Basic design example - Orthogonal ratio

0.42 = 0.45

0.19 =

f

f

kp

kb

Orthogonal ratio = fkb/fkp

Page 28: Masonry Revision 2007 08

Basic example - Aspect ratio

1.0 = 4.5

4.5 =

L

hAspect ratio =

Page 29: Masonry Revision 2007 08

Moment coefficients () Table 8

• From BS 5628 Table 8A• Support conditions-simple• for h/L = 1.0

α = 0.083 with μ = 0.5α = 0.087 with μ = 0.4

• Therefore by linear interpolation• α = 0.0862 when μ = 0.42

μ (required) = 0.42

Page 30: Masonry Revision 2007 08

Applied design moment per unit height

• Since Wk = 0.45 kN/m2 ,

• γf = 1.2,

• L=4.5

• α = 0.0862

m = 0.0862 x 0.45 x 1.2 x 4.52

= 0.943 kNm/m

Page 31: Masonry Revision 2007 08

Design moment of resistance.(Clause 32.4.3)

• For a panel bending in two directions

m

kp Zf =M

Now, fkp = 0.45, t = 190

then M = 0.45 x 1902 x 10-3

3.0 x 6 = 0.903 kNm/m (<0.943)

[Not OK]

Page 32: Masonry Revision 2007 08

Applied moment(Second try)

• Using a 215 block

• fkb = 0.17, fkp = 0.41

• μ = 0.17/0.41 = 0.41

• α = 0.0866

• Hence m = 0.947 kNm/m

Page 33: Masonry Revision 2007 08

Design moment of resistance(Second try)

• Now, fkp = 0.41, t = 215

• M = 0.41 x 2152 x 10-3

3.0 x 6

= 1.053 kNm/m (> 0.947) [Therefore OK]• Therefore use block of thickness 215mm (7.3

N/mm2)

For a panel bending in two directions

m

kp Zf =M

Page 34: Masonry Revision 2007 08

Basic example - Slenderness limits

(Clause 32.3)• For a panel simply supported on more than one side. h x L 1350 tef

2

• since wall is single leaf tef = t

mm123 1350

104.5x4.5x

1350

hx1t

6

Page 35: Masonry Revision 2007 08

Basic example - Slenderness limits

(Clause 32.3)• In addition no dimension shall exceed 50 tef. since h and L both = 4.5 then

mm90 50

104.5x t

3

Page 36: Masonry Revision 2007 08

Basic example - Shear design(Clause 21)

• Consider the wind load to be distributed to the supports as shown below

4.5m

4.5m

45o

Page 37: Masonry Revision 2007 08

Basic example - Shear design(Clause 21)

Total load to support = γfWkx(loaded area)

Total shear along base

= 1.2 x 0.45 x {(4.5 x 2.25)/2} = 2.734 kN

Assume this is a udl along base

Design SF per metre run, is

kN 0. = 5

2.734 = 61

.4

Page 38: Masonry Revision 2007 08

Basic example - Shear design(Clause 21)

The design shear stress (vh) is therefore

vh = 0.61 x 103 = 0.0028 N/mm2

215 x 1000

Page 39: Masonry Revision 2007 08

Basic example - Shear design(Clause 21)

Charac. shear strength (fv) from clause 21

= 0.35 + 0.6 gd

Ignoring self weight, characteristic strength

fv = 0.35 N/mm2

Page 40: Masonry Revision 2007 08

Basic example - Shear design(Clause 21)

• Design shear stress (vh) limited so

mv

vh

f v

vh = 0.0028 N/mm2

mmN/ 0.14 = 2.5

0.35 =

f 2

mv

v

Therefore OK along base

Page 41: Masonry Revision 2007 08

Basic example - Shear design(Clause 21)

Total shear to each vertical support

= 1.2 x 0.45 x 2.25 (2.25 + 4.5) = 4.10 kN 2

Assume this load to be a udl up the sides, design shear force per metre run

= 4.10 = 0.91 kN

4.5

Page 42: Masonry Revision 2007 08

Basic example - Shear design(Clause 21)

• Use 2 mm thick anchors into dovetail slots in column.• Charac. strength of each tie = 4.5 kN, (Manuf. Data)

• Place ties at 900 mm centres. Assume m = 3.0.

• Design load resistance per metre run of wall

= 4.5 x 1000 = 1.67 kN > design shear force

3.0 900

Vertical shear adequate

Page 43: Masonry Revision 2007 08

Tutorial - Problem 1

Continuous supports

h

L

Free edge

Simple supports

Page 44: Masonry Revision 2007 08

Determine the max. wind load a single leaf brick wall 103mm thick supported as shown may sustain.

• Height of wall to free edge = 2.6 m• Length of wall between restraints = 3.47 m• Bricks (water absorption between 7.0 and 12.0%)• Mortar of designation (iii) [M6 and M4]• Normal category construction control• Category I or II of units

• Panel not providing stability to structure, γf = 1.2

• In this example, ignore the effects of self weight

γm = 3.1

Page 45: Masonry Revision 2007 08

Tutorial - Problem 2• As for problem 1 but include self weight

Density of the brickwork is 22.0kN/m3

Page 46: Masonry Revision 2007 08

Tutorial - Problem 3

Joint at floor

Concrete columns

Blockwork

BrickworkPLAN

ELEVATION

Page 47: Masonry Revision 2007 08

• Design a cavity wall, 4.5m by 3.375m high to withstand a wind pressure of 0.6 kN/m2.

• Outer leaf - Clay brickwork running past supporting columns – (Water absorption > 12%) – (mortar designation (iii)). [Mortar M4 or M6]– Density 17.0kN/m3

• Inner leaf Blockwork abutting the columns with a soft control joint. – Thickness of leaves = 100 mm.– Density of blockwork = 10.0 kN/m3.

Page 48: Masonry Revision 2007 08

Tutorial - Problem 4

4.0m

1.5m

1.0m

1.5m

1.5m 1.0m 1.5m

Opening

Continuous supports

Design a single leaf wall panel, 4m long by 4m high, with a centrally placed 1.0 x 1.0m window to resist a characteristic wind pressure of 0.6 kN/m2. All edges are considered to be fixed.

γm = 3.0 γf = 1.2

10.4 N/mm2 blocks

Page 49: Masonry Revision 2007 08

Concentrated loads

Page 50: Masonry Revision 2007 08

Question Concentrated loads.

• A 300mm wide x 500mm deep reinforced concrete beam is to be built into a 100mm thick masonry wall. The masonry is assumed to comprise 7.3N/mm2 concrete blocks in designation (iii) [M4] mortar. The blocks are 215mm high and the partial factor for materials has been assessed to be 3.5. The reaction at the end of the beam is 50.0kN and a uniformly distributed load of 20.0kN/m exists along the wall at the level of the top of the beam. The density of the concrete blockwork is 20kN/m3, and the wall is supported 2400mm below the beam on a level slab. For design purposes, assume the wall is pinned at the top and bottom. Is the blockwork selected adequate?

• Can you improve on this design? Discuss what would happen if the wall was 140mm wide?

Page 51: Masonry Revision 2007 08

45o

2400mm

0.4 x 2400 = 960mm

A

B

Figure 1Layout of problem

300 x 500mm deep RC beam

Page 52: Masonry Revision 2007 08

Solution.• Check at level A.• Masonry strength [ht/least dim of blocks • = 2.15] = 6.4N/mm2 Table 2 BS5628 Part 1

• Figure 4 – bearing type 1

• Enhance strength by 1.25, strength • = 6.4 x 1.25 = 8.0N/mm2

• Design strength of masonry • = 8.0/3.5 = 2.28N/mm2

• Stress imposed on masonry • = (50 x 103)/(300 x 100) = 1.67N/mm2 so OK

Page 53: Masonry Revision 2007 08

• Check 0.4h m down.• Masonry strength = βtfk/γm • Determination of β : • Depends on :- • Slenderness ratio = effective height/effective thickness • = 2400/100 = 24• Eccentricity of load. • This needs to be determined 0.4m down. • Axial load [udl along wall over 0.960 x 2 + 0.3 = 2.22m] • = 20 x 2.22 = 44.4kN• Axial load from 1460mm of masonry along 2.22m • = 20 x 0.1 x 1.46 x 2.22 = 6.48kN• Moments about centre line.• 50 x 16.67 = 100.88 x e, so e = 8.3mm = 0.08t• Determination of β : From table 7 and by interpolation• β = 0.47 + 0.4 x 0.03 = 0.482• Stress capacity at 0.4m down = βtfk/γm = 0.482 x 6.4/3.5 =

0.88N/mm2

• Applied stress in masonry = (100.88 x 103)/(2220 x 100) • = 0.45N/mm2 so OK

50.88kN 50.0kN

R = 100.88kN

e

t/6=16.7mm

Page 54: Masonry Revision 2007 08

Other areas

Page 55: Masonry Revision 2007 08

Combined vertical and lateral load

• qlat = (4tn)/ha

h a

qlat

Page 56: Masonry Revision 2007 08

Diaphragm walls

• When would they be used.

• What are the principles of their design

• Advantages and disadvantages

Page 57: Masonry Revision 2007 08

Retaining walls

• Drainage

• Sulphate and frost protection

Page 58: Masonry Revision 2007 08

Reinforced masonry

• Pocket walls

• Infill walls

• Reinforcement

• Details

• Max and min reinforcement