Top Banner
Marysville Wire Based Ethernet System John Tatum Traffic Engineer City of Marysville
9

Marysville Wire Based Ethernet System John Tatum Traffic Engineer City of Marysville.

Dec 19, 2015

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Marysville Wire Based Ethernet System John Tatum Traffic Engineer City of Marysville.

Marysville Wire Based Ethernet System

John TatumTraffic Engineer

City of Marysville

Page 2: Marysville Wire Based Ethernet System John Tatum Traffic Engineer City of Marysville.

For those of us with wire still left in the ground

There is a box that can make it talk fast

Page 3: Marysville Wire Based Ethernet System John Tatum Traffic Engineer City of Marysville.

EoVDSL

• Eo Ethernet over• V very high bit rate• DSL Digital Subscriber Line

Page 4: Marysville Wire Based Ethernet System John Tatum Traffic Engineer City of Marysville.

Enhanced Rapid Spanning Tree Protocol (eRSTP™)

RuggedCom eRSTP allows the creation of fault-tolerant ring and mesh Ethernet networks that incorporate redundant links that are 'pruned' to prevent loops.

Page 5: Marysville Wire Based Ethernet System John Tatum Traffic Engineer City of Marysville.

RJ11 Ethernet over VDSL Port

The unit contains one EoVDSL data port that allows connection to Category 3 (CAT-3) unshielded twisted-pair (UTP) cable with RJ11 male connectors. The figure below shows the RJ45 port pin-out and LEDs.

Page 6: Marysville Wire Based Ethernet System John Tatum Traffic Engineer City of Marysville.

Wiring

VDSL typically operates over 2-wire CAT-3 wiring; however, other categorized or uncategorized twisted-pair wiring will work although the performance will vary depending on the distance and cable characteristics.

Page 7: Marysville Wire Based Ethernet System John Tatum Traffic Engineer City of Marysville.

Performance

On 24 American Wire Gauge (AWG) Polyethylene Insulated Cable (PIC) twisted-pair the following performance is typical:

Distance Distance Downstream/Upstream Time to Achieve Port Up [km] [feet] [Mbps] [Seconds]0.5 1600 35.00 150.6 2000 30.00 300.7 2300 25.00 450.8 3000 20.00 601.0 3300 15.00 751.3 4300 10.00 901.7 5600 5.00 1052.0 6600 2.50 1202.5 8200 1.00 135

Table 5 - Typical Performance on 24 AWG PIC twisted-pair

Page 8: Marysville Wire Based Ethernet System John Tatum Traffic Engineer City of Marysville.

South Marysville System

Page 9: Marysville Wire Based Ethernet System John Tatum Traffic Engineer City of Marysville.

System Distances

• 3rd to 4th on 47th 350’ 35 Mbps• State to 47th on 4th 2400’ 24

Mbps• Cedar to State on 4th 800’ 35 Mbps• 4th to 1st on State 1000’ 35

Mbps