Top Banner
Mariana Petris, NIPNE Buc harest CBM Meeting, March 9 - 12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests
17

Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

Jan 29, 2016

Download

Documents

Hector Parrish
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005

HIGH COUNTING RATE TRANSITION RADIATION

DETECTORBucharest Prototype

In Beam Tests

Page 2: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

Transition Radiation Detectors

ALICE - TRD ATLAS - TRT

- type (radiator+drift chamber + MWPC) (radiator + straw tubes)

- rej (at 90% e efficiency) 100 100

- Maximum drift time 2 s 40 ns

- Counting rates ~ 100 Hz/cm2 ~ 1MHz/ cm2

- Granularity (channel size) high (~6 cm2) low (~20cm2) CBM - TRD

Counting rates ~ 100 KHz/cm2

High granularity

- rej (at 90% e efficiency) > 100

Page 3: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

HCRTRD - prototype

- type: radiator + MWPC; 2.5 mm anode pitch

- maximum drift time: ~ 100 ns

- channel size: 6 cm2

Page 4: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

55Fe Source Tests

IFIN - HH 55Fe tests

30% CO2 + 70% Ar

HV 1920 V;

Readout: PASA (2 mV/fC, 1800 e

rms) + ADC Converter

Energy Resolution :

~10% ();

~25% FWHM

GSI 55Fe tests

15% CO2 + 85% Ar

HV 1700 V;

Readout:PASA (2mV/fC, 1800 e

rms) + FADC Converter

Energy Resolution:

~ 8.6 % ();

~20 % FWHM

Page 5: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

Beam Test

Goal of the experiment: detector performance in high counting rate environment

Experimental Setup:

- 2 Scintillators (ToF, trigger);

- 2 Si - Strip Detectors (position information);

- 2 MWPC - GSI (10 x 10 cm2 )

- 1 MWPC - Bucharest (24 x 24 cm2 )

-1 MWPC - Dubna (10 x 10 cm2 )

- 1 GEM - Dubna

- Pb - glass calorimeter (last run)

- FADC readout ; DAQ (MBS)

Page 6: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

Beam Composition

e/ vs. rate not possible, too low e intensities at SIS

/p @ 1 GeV/c too low rates;

p/d @ 2 GeV/c rate dependence studies.

p

p p d

p d

Page 7: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

Beam Profile

x1 > 10 mm; x2 > 10 mm;

Si1 length 20;

Si2 length 20.

2 s 2 s

0.2 s 0.2 s

Page 8: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

2 s

1850 V

0.2 s

1850 V

Gain - 2s spill length,for protons

Page 9: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

Average Pulse Height15% CO2 + 85% Ar, continuous anode, 1750 V 15%CO2 + 85% Ar, split anode, 1725 V

1 s

0.5 s

<P

H>

(mV

/0.7

4) 2 s

1 s

0.5 s

0.2 s

2 s

1 s

0.5 s

0.2 s

0 %

0.7 %

3.5 %

13.3%

0 %

0 %

0 %

2%

Page 10: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

ToF Spectra

Page 11: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

Pulse Height and Charge Spectra

Page 12: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

e/ Discrimination

Page 13: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

Pulse Height and Charge Spectra

MPV value (from landau fit of PH and Q proton spectra) as a function of rate

Page 14: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

High Counting Rate Effect

(4.2 1.2) %

(3.2 2.1) %

(11.7 1.8) %

(0.4 1) %

Page 15: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

High Counting Rate Effect

(8.9 1.4) %

(5 3.4) %

(8.4 3.9) %

(2.2 1.4) %

Page 16: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

High Counting Rate Effect

(6.8 1.5) %

(3.2 1.1) %

(5.8 1.9) %

(3.4 1.5) %

Page 17: Mariana Petris, NIPNE Bucharest CBM Meeting, March 9 -12, 2005 HIGH COUNTING RATE TRANSITION RADIATION DETECTOR Bucharest Prototype In Beam Tests.

Conclusions

•Diagnostic system

not specific for hcr

environment

limited performance

The results of the first in-beam tests of such a geometry seem to

recommend it as a solution for a major percentage of the CBM

TRD subdetector.

Participants: Bucharest, Dubna, GSI, Heidelberg and Münster

•Modest statistics

limiting factor for

detailed analysis in terms

of:

- Beam profile

- Spill profile

•Much to low

systematics for

negatives (e/)

Although