12 DEVIATORI DI FLUSSO www.hydrapac.it
22

MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

Mar 07, 2016

Download

Documents

MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

12

DEVIATORI DI FLUSSO

www.hydrapac.it

Page 2: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

A B

P

A B

Ppos. 1 pos. 2 pos. 1 pos. 2

0

0,5

1

1,5

2

2,5

3

3,5

4

4,5

5

0 20 40 60 80 100 120 140 160 180

FLOW - Q (l/min)

DF3 3/8"

DF3 1/2"

DF3 1"

DF3 3/4"

P A/B

∆P

(Bar)

186

PERDITE DI CARICOPRESSURE DROPS CURVE

12.1 - DEVIATORI DI FLUSSO A 3 VIE12.1 - 3-WAYS DIVERTER VALVES

IMPIEGO:Valvole utilizzate per deviare il flusso in ingresso verso due bocche d’uscita.

MATERIALI E CARATTERISTICHE:Corpo: ghisaComponenti interni: acciaio temprato termicamente e rettificatoGuarnizioni: BUNA N standardTenuta: trafilamento trascurabile

MONTAGGIO:Collegare P all’alimentazione e le bocche A e P ai rami del circuito idraulico a cui si vuole deviare il flusso. Con leva in pos. 1 si alimenta la bocca A, con leva in pos. 2 si alimenta la bocca B. Con leva in posizione centrale le bocche P, A e B sono tutte collegate (centro aperto).

A RICHIESTA:• Centro chiuso (CODICE/CC)• Alta pressione - fino a 400 Bar (CODICE/AP)

USE AND OPERATION:3 ways diverter valves is used to divert the flow towards 2 different outlets.

MATERIALS AND FEATURES:Body: cast ironInternal parts: hardened and ground steelSeals: BUNA N standardTightness: minor leakage

APPLICATIONS:Connect P to the pressure flow, A and P to the ports of the hydraulic circuit where flow has to be diverted. With lever in position 1 the flow is connected towards port A; with lever in position 2, the flow is connected towards port B. With lever in central position ports P, A and B are all connected (open centre).

ON REQUEST• Closed centre (CODE/CC)• High pressure - up to 400 Bar (CODE/AP)

TIPO/TYPE

DF 3

SCHEMA IDRAULICO (con centro aperto)

HYDRAULIC DIAGRAM (with opened centre)

A RICHIESTA(con centro chiuso)ON REQUEST(with closed centre)

Temperatura olio: 50°C - Viscosità olio: 30 cStOil temperature: 50°C - Oil viscosity: 30 cSt

www.hydrapac.it

Page 3: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

12

CODICECODE

SIGLATYPE

PORTATA MAXMAX FLOW

Lt./min

PRESSIONE MAXMAX PRESSURE

Bar

V0880 DF 3 VIE ⅜” 35 250

V0890 DF 3 VIE ½” 60 250

V0900 DF 3 VIE ¾” 100 250

V0910 DF 3 VIE 1” 180 250

CODICECODE

SIGLATYPE

A – BP

L L1 L2 L3 L4 ØG HPESO

WEIGHT

GAS mm mm mm mm mm mm mm Kg

V0880 DF 3 VIE ⅜” G ⅜” 76 140 68 25 26 8,5 67 0,914

V0890 DF 3 VIE ½” G ½” 87 145 80 28 32 8,5 70 1,392

V0900 DF 3 VIE ¾” G ¾” 103 150 94 30 32 11 78 2,030

V0910 DF 3 VIE 1” G 1” 105 152 98 30 32 11 82 2,144

H

L3

L1

L2P

L4

LA B

ØGpos. 2 pos. 1

187

Page 4: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

A B

P

A B

Ppos. 1 pos. 2 pos. 1 pos. 2

188

12.2 - DEVIATORE DI FLUSSO A 3 VIE ALTA PRESSIONE IN ACCIAO12.2 - HIGH PRESSURE 3-WAYS DIVERTER VALVES, STEEL BODY

IMPIEGO:Valvole utilizzate per deviare il flusso in ingresso verso due bocche d’uscita.

MATERIALI E CARATTERISTICHE:Corpo: acciaioComponenti interni: acciaio temprato termicamente e rettificatoGuarnizioni: BUNA N standardTenuta: trafilamento trascurabile

MONTAGGIO:Collegare P all’alimentazione e le bocche A e P ai rami del circuito idraulico a cui si vuole deviare il flusso. Con leva in pos. 1 si alimenta la bocca A, con leva in pos. 2 si alimenta la bocca B. Con leva in posizione centrale le bocche P, A e B sono tutte collegate (centro aperto).

USE AND OPERATION:Diverter flow is used to divert the flow towards 2 different outlets.

MATERIALS AND FEATURES:Body: steelInternal parts: hardened and ground steelSeals: BUNA N standardTightness: minor leakage

APPLICATIONS:Connect P to the pressure flow, A and P to the ports of the hydraulic circuit where flow has to be diverted. With lever in position 1 the flow is connected towards port A; with lever in position 2, the flow is connected towards port B. With lever in central position ports P, A and B are all connected (open centre).

SCHEMA IDRAULICO (con centro aperto)

HYDRAULIC DIAGRAM (with opened centre)

A RICHIESTA(con centro chiuso)ON REQUEST(with closed centre)

Page 5: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

12

CODICECODE

SIGLATYPE

PORTATA MAXMAX FLOW

Lt/min.

PPRESSIONE MAXMAX PRESSURE

Bar

PESOWEIGHT

Kg

V0879/AP DF 3 VIE ¼” AP ACC. 20 500 0,65

V0881/AP DF 3 VIE ⅜” AP ACC. 35 500 0,72

V0891/AP DF 3 VIE ½” AP ACC. 60 500 0,92

V0901/AP DF 3 VIE ¾” AP ACC. 100 500 1,57

V0911/AP DF 3 VIE 1” AP ACC. 180 500 2,17

CODICECODE

SIGLATYPE

M A B C E F ØG H L LW N Q ØR ØS SW

GAS mm mm mm mm mm mm mm mm mm mm mm mm mm mm

V0879/AP DF 3 VIE ¼” AP ACC. G ¼” 33 15 55 16 49 62 110 15,5 6 26 10 8,5 13,5 9

V0881/AP DF 3 VIE ⅜” AP ACC. G ⅜” 38 17,5 55 16 54 62 110 15,5 8 26 10 8,5 13,5 9

V0891/AP DF 3 VIE ½” AP ACC. G ½” 43 20 60 16 59 67 110 17 11 32 11 10,5 13,5 9

V0901/AP DF 3 VIE ¾” AP ACC. G ¾” 48 22,5 75 20,5 68,5 82 180 21 12 32 14 10,5 16,5 14

V0911/AP DF 3 VIE 1” AP ACC. G 1” 53 25 85 20,5 73,5 97 180 21 16 32 14 10,5 16,5 14

P

B A

C

ØS

ØR

C

A E

F

SW

45° 45°

H

Q

N

ØG

B

pos. 1pos. 2

189

Page 6: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

A B

P Tpos. 1 pos. 2

∆P

(Bar)

0

0,5

1

1,5

2

2,5

3

0 10 20 30 40 50 60 70 80 90 100

FLOW - Q (l/min)

IF4 3/8"

IF4 3/4"

IF4 1/2"

P A/B

A B

P Tpos. 1 pos. 2

190

PERDITE DI CARICOPRESSURE DROPS CURVE

12.3 - INVERTITORI DI FLUSSO A 4 VIE12.3 - 4-WAYS DIVERTER VALVES

IMPIEGO:Valvole utilizzate per invertire il flusso dell’olio da due ingressi a due uscite. Possono essere impiegati per azionare attuatori a doppio effetto o per invertire la rotazione di un motore idraulico.

MATERIALI E CARATTERISTICHE:Corpo: ghisaComponenti interni: acciaio temprato termicamente e rettificatoGuarnizioni: BUNA N standardTenuta: trafilamento trascurabile

MONTAGGIO:Collegare P all’alimentazione, T al serbatoio e le bocche A e B all’attuatore o al motore. Con leva in pos. 1, P alimenta A e contemporaneamente B va allo scarico T; con leva in pos. 2, P alimenta B e contemporaneamente A va allo scarico T. Con leva in posizione centrale tutte le bocche sono chiuse (centro chiuso).

A RICHIESTA:• Centro aperto (CODICE/CA)• Alta pressione - fino a 400 Bar (CODICE/AP)

USE AND OPERATION:This valve is used to reverse oil flow from 2 ways in towards two ways out. It could be used to control a double acting actuators or to reverse the rotation of an hydraulic motor.

MATERIALS AND FEATURES:Body: cast ironInternal parts: hardened and ground steelSeals: BUNA N standardTightness: low leakage

APPLICATIONS:Connect P to the pressure flow, T to the tank and ports A and B to the actuators or motor. With lever in position 1, P is connected to A and at the same time B drains into the tank T; with lever in position 2, P is connected to B and at the same time A drains into tank T. With lever in central position all ports are closed (closed centre). ON REQUEST• Open centre (CODE/CA).• High pressure - up to 400 Bar (CODE/ AP)

TIPO/TYPE

IF 4

SCHEMA IDRAULICO (con centro chiuso)

HYDRAULIC DIAGRAM (with closed centre)

A RICHIESTA(con centro aperto)ON REQUEST(with opened centre)

Temperatura olio: 50°C - Viscosità olio: 30 cStOil temperature: 50°C - Oil viscosity: 30 cSt

Page 7: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

12

CODICECODE

SIGLATYPE

PORTATA MAXMAX FLOW

Lt./min

PRESSIONE MAXMAX PRESSURE

Bar

V0970 IF 4 VIE ⅜” 35 250

V0980 IF 4 VIE ½” 60 250

V0990 IF 4 VIE ¾” 100 250

CODICECODE

SIGLATYPE

A – BP – T

L L1 L2 L3 L4 ØG HPESO

WEIGHT

GAS mm mm mm mm mm mm mm Kg

V0970 IF 4 VIE ⅜” G ⅜” 76 140 76 26 54 8,5 72 1,346

V0980 IF 4 VIE ½” G ½” 88 145 88 30 65 8,5 82 1,928

V0990 IF 4 VIE ¾” G ¾” 95 180 95 32 74 8,5 90 2,534

L1

TPL

L4A

B

L2

L3

H

ØG

pos. 1pos. 2

191

Page 8: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

AB

P

A'B'

P'

AB

P

A'B'

P'pos. 1 pos. 2 pos. 1 pos. 2

∆P

(Bar)

0

0,5

1

1,5

2

2,5

3

3,5

4

4,5

5

0 20 40 60 80 100 120 140 160 180

FLOW - Q (l/min)

DF6 3/8"

DF6 1"

DF6 3/4"

DF6 1/2"

P A/A’P B/B’

192

PERDITE DI CARICOPRESSURE DROPS CURVE

12.4 - DEVIATORI DI FLUSSO A 6 VIE12.4 - 6-WAYS DIVERTER VALVES

IMPIEGO:Valvole formate da due deviatori a 3 vie accoppiati: ognuna delle due sezioni ha la funzione di deviare il flusso da una sola alimentazione a due uscite. Tramite un’unica leva si azionano contemporaneamente le due sezioni. Possono essere utilizzati per azionare due attuatori.

MATERIALI E CARATTERISTICHE:Corpo: ghisaComponenti interni: acciaio temprato termicamente e rettificatoGuarnizioni: BUNA N standardTenuta: trafilamento trascurabile

MONTAGGIO:Collegare P e P’ alle due alimentazioni, le bocche A e B al primo attuatore e le bocche A’ e B’ al secondo attuatore. Con leva in pos. 1 P alimenta A e P’ alimenta A’, con leva in pos. 2 P alimenta B e P’ alimenta B’. Con leva in posizione centrale le bocche di ogni sezione sono tra loro collegate (centro aperto).

A RICHIESTA:• Centro chiuso (CODICE/CC)• Alta pressione - fino a 400 Bar (CODICE/AP)

USE AND OPERATION:This valve is made up by two 3-ways diverters coupled: each of the 2 parts is used to divert the inlet flow towards two ports. The single lever controls both the parts at the same time. It’s ideal to control 2 actuators.

MATERIALS AND FEATURES:Body: cast ironInternal parts: hardened and ground steelSeals: BUNA N standardTightness: minor leakage

APPLICATIONS:Connect P and P’ to the 2 pressure flows, ports A and B to the first actuator and ports A’ and B’ to the second actuator. With lever in position 1, P is connected to A and P’ to A’; with lever in position 2, P is connected to B and P’ to B’. With lever in central position all ports are connected among each other (opened centre). ON REQUEST• Closed centre (CODE/CC)• High pressure - up to 400 Bar (CODE/ AP)

TIPO/TYPE

DF 6

Temperatura olio: 50°C - Viscosità olio: 30 cStOil temperature: 50°C - Oil viscosity: 30 cSt

SCHEMA IDRAULICO (con centro aperto)

HYDRAULIC DIAGRAM (with opened centre)

A RICHIESTA(con centro chiuso)ON REQUEST(with closed centre)

Page 9: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

12

CODICECODE

SIGLATYPE

PORTATA MAXMAX FLOW

Lt./min

PRESSIONE MAXMAX PRESSURE

Bar

V0920 DF 6 VIE ⅜” 35 250

V0940 DF 6 VIE ½” 60 250

V0950 DF 6 VIE ¾” 100 250

V0960 DF 6 VIE 1” 180 250

CODICECODE

SIGLATYPE

A – BP

L L1 L2 L3 L4 ØG HPESO

WEIGHT

GAS mm mm mm mm mm mm mm Kg

V0920 DF 6 VIE ⅜” G ⅜” 76 140 68 45 26 8,5 117 1,688

V0940 DF 6 VIE ½” G ½” 87 145 80 51 32 8,5 125 2,628

V0950 DF 6 VIE ¾” G ¾” 103 150 94 55 32 11 140 4,634

V0960 DF 6 VIE 1” G 1” 105 152 98 60 32 11 155 4,238

L1

L2P

L4

LA B

ØG

L3

H

pos. 2 pos. 1

193

Page 10: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

A B

P

A'B'

P'pos. 1 pos. 2

0

0,2

0,4

0,6

0,8

1

1,2

1,4

1,6

1,8

2

0 5 10 15 20 25 30 35 40 45 50 55 60

FLOW - Q (l/min)

DF6A 3/8"

DF6A 1/2"

P A/BP’ A’/B’

∆P

(Bar)

SCHEMA IDRAULICOHYDRAULIC DIAGRAM

194

PERDITE DI CARICOPRESSURE DROPS CURVE

12.5 - DEVIATORI DI FLUSSO A 6 VIE IN ACCIAIO12.5 - 6-WAYS DIVERTER VALVES, STEEL BODY

IMPIEGO:Valvole utilizzate per deviare il flusso da due entrate a 4 uscite (2 per volta alternativamente). Possono essere utilizzati per alimentare due attuatori.

MATERIALI E CARATTERISTICHE:Corpo: accaio zincatoComponenti interni: acciaio temprato termicamente e rettificatoGuarnizioni: BUNA N standardTenuta: trafilamento trascurabile

MONTAGGIO:Collegare P e P’ alle due alimentazioni, le bocche A e B al primo attuatore e le bocche A’ e B’ al secondo attuatore. Con leva in pos. 1 P alimenta A e P’ alimenta A’, con leva in pos. 2 P alimenta B e P’ alimenta B’. È sconsigliato l’uso del deviatore con leva in posizione centrale.

USE AND OPERATION:This valve is used to divert the flow from 2 ways in towards 4 ports (two at time alternatively). It’s ideal to control 2 actuators.

MATERIALS AND FEATURES:Body: zinc-plated steelInternal parts: hardened and ground steelSeals: BUNA N standardTightness: minor leakage

APPLICATIONS:Connect P and P’ to the 2 pressure flows, ports A and B to the first actuator and ports A’ and B’ to the second actuator. With lever in position 1, P is connected to A and P’ to A’; with lever in position 2, P is connected to B and P’ to B’. Use with lever in central position is not recommended

TIPO/TYPE

DF 6A

Temperatura olio: 50°C - Viscosità olio: 30 cStOil temperature: 50°C - Oil viscosity: 30 cSt

Page 11: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

12

CODICECODE

SIGLATYPE

PORTATA MAXMAX FLOW

Lt./min

PRESSIONE MAXMAX PRESSURE

Bar

V0930 DF 6 VIE ⅜” ACCIAIO 40 300

V0932 DF 6 VIE ½” ACCIAIO 60 300

CODICECODE

SIGLATYPE

A – BP

L L1 L2 L3 L4 ØD H H1 GPESO

WEIGHT

GAS mm mm mm mm mm mm mm mm mm Kg

V0930 DF 6 VIE ⅜” ACCIAIO G ⅜” 60 140 58 32 25 47 74 96 M8 1,540

V0932 DF 6 VIE ½” ACCIAIO G ½” 69 145 66 37 27 47 83 105 M8 2,294

H1

H

L4L3P

L2

ØD A

B

G

L1

L

pos. 1 pos. 2

195

Page 12: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

13

VALVOLE FINECORSA

Page 13: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

P

A

0

0,5

1

1,5

2

2,5

0 20 40 60 80 100 120 140

FLOW - Q (l/min)

1T80

1T120

1T60

∆P

(Bar)

P A

SCHEMA IDRAULICOHYDRAULIC DIAGRAM

198

PERDITE DI CARICOPRESSURE DROPS CURVE

13.1 - FINECORSA IN TRAZIONE E SPINTANORMALMENTE APERTO13.1 - END STROKE VALVES, NORMALLY OPENED

IMPIEGO:Valvola utilizzata per bloccare l’immissione di olio in un circuito idraulico o per fermare la corsa di un attuatore (valvola normalmente aperta). La chiusura della valvola, ottenuta azionando il cursore in trazione o spinta, permette un arresto immediato e totale del flusso di olio.

MATERIALI E CARATTERISTICHE:Corpo: ghisaComponenti interni: acciaio temprato termicamente e rettificatoGuarnizioni: BUNA N standardTenuta: trafilamento trascurabile

MONTAGGIO:Collegare P al distributore e A al circuito o all’attuatore. Con il cursore azionato il flusso è bloccato da P ad A mentre, nella direzione opposta, la valvola di ritegno permette il libero passaggio dell’olio da A a P.

USE AND OPERATION:This valve is used to stop oil inlet in a hydraulic circuit or to stop actuator’s stroke (normally opened valve). The valve closing, obtained by pulling or pushing the slider, allows an immediate and total stop of the oil flow.

MATERIAL AND FEATURESBody: cast ironInternal parts: grounded and hardened steelSeals: BUNA N standardTightness: minor leakage

APPLICATIONS:Connect P to the distributor and A to the circuit or to the actuator. When slider is operating, flow is blocked from P towards A, whilst the check valve enables free oil flow in the reverse direction (from A towards P).

TIPO/TYPE

V-FCR 1T

Temperatura olio: 50°C - Viscosità olio: 30 cStOil temperature: 50°C - Oil viscosity: 30 cSt

Page 14: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

13

CODICECODE

SIGLATYPE

PORTATA MAXMAX FLOW

Lt./min

PRESSIONE MAXMAX PRESSURE

Bar

INIZIO CHIUSURASTART CLOSING

mm

FORZAPOWER

Kg (±10%)

CORSA MAXMAX STROKE

mm

FORZAPOWER

Kg (±10%)

V0824 V-FCR 1T 60 60 350 7 6,5 20,5 18

V0826 V-FCR 1T 80 80 350 7 6,5 20,5 18

V0825 V-FCR 1T 120 120 350 9 33 15,5 50

CODICECODE

SIGLATYPE

A – P L L1 L2 L3 L4 L5 L6 ØG ØG1 H H1PESO

WEIGHT

GAS mm mm mm mm mm mm mm mm mm mm mm Kg

V0824 V-FCR 1T 60 G ⅜” 69 130 66 45 45 41 103 8,5 6,5 26 68 1,628

V0826 V-FCR 1T 80 G ½” 69 130 66 45 45 41 103 8,5 6,5 26 68 1,616

V0825 V-FCR 1T 120 G ¾” 88 173 50 56 46 23,5 92 8,5 13 27,5 50 2,112

H

L4L5

L6

L2

L3

L

L1

ØG

H1

ØG1

P

A

A

L2

P

L

L1

L3

L4

H

H1

L6

L5

ØG

ØG

1

199

V-FC

R 1T

60

- 80

V-FC

R 1T

120

Page 15: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

P

A

0

0,5

1

1,5

2

2,5

3

3,5

4

0 20 40 60 80 100 120 140

FLOW - Q (l/min)

2T80

2T120

2T60 P A

SCHEMA IDRAULICOHYDRAULIC DIAGRAM

200

PERDITE DI CARICOPRESSURE DROPS CURVE

13.2 - FINECORSA IN TRAZIONE E SPINTANORMALMENTE CHIUSO13.2 - END STROKE VALVES, NORMALLY CLOSED

IMPIEGO:Valvola utilizzata per aprire il passaggio di olio in un circuito idraulico (valvola normalmente chiusa). L’apertura della valvola è ottenuta azionando il cursore in trazione o spinta.

MATERIALI E CARATTERISTICHE:Corpo: ghisaComponenti interni: acciaio temprato termicamente e rettificatoGuarnizioni: BUNA N standardTenuta: trafilamento trascurabile

MONTAGGIO:Collegare A e P indifferentemente al distributore e al circuito. Quando il cursore è azionato il flusso è libero in entrambe le direzioni, viceversa il flusso è bloccato.

USE AND OPERATION:This valve is used to enable oil inlet in a hydraulic circuit (normally closed valve). The valve opens by pulling or pushing the slider.

MATERIAL AND FEATURESBody: cast ironInternal parts: grounded and hardened steelSeals: BUNA N standardTightness: minor leakage

APPLICATIONS:Connect independently A and P to the distributor and to the circuit. When slider is operating, flow is free in both directions, vice versa it is blocked.

TIPO/TYPE

V-FCR 2T

Temperatura olio: 50°C - Viscosità olio: 30 cStOil temperature: 50°C - Oil viscosity: 30 cSt

Page 16: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

13

CODICECODE

SIGLATYPE

A – P L L1 L2 L3 L4 L5 L6 ØG ØG1 H H1PESO

WEIGHT

GAS mm mm mm mm mm mm mm mm mm mm mm Kg

V0820 V-FCR 2T 60 G ⅜” 69 130 66 45 45 41 103 8,5 6,5 26 68 1,648

V0822 V-FCR 2T 80 G ½” 69 130 66 45 45 41 103 8,5 6,5 26 68 1,652

V0823 V-FCR 2T 120 G ¾” 88 179 50 56 46 23,5 92 8,5 13 27,5 50 2,204

H

L4L5

L6

L2

L3

L

L1

ØG

H1

ØG1

P

A

A

L2

P

L

L1

L3

L4

H

H1

L6

L5

ØG

ØG

1

CODICECODE

SIGLATYPE

PORTATA MAXMAX FLOW

Lt./min

PRESSIONE MAXMAX PRESSURE

Bar

INIZIO APERTURASTART OPENING

mm

FORZAPOWER

Kg (±10%)

CORSA MAXMAX STROKE

mm

FORZAPOWER

Kg (±10%)

V0820 V-FCR 2T 60 60 350 7 6,5 20,5 18

V0822 V-FCR 2T 80 80 350 7 6,5 20,5 18

V0823 V-FCR 2T 120 120 350 9 33 15,5 50

201

V-FC

R 2T

60 -

80

V-FC

R 2T

120

Page 17: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

A

P

∆P

(Bar)

P A

0

0,5

1

1,5

2

2,5

3

0 20 40 60 80 100 120 140

FLOW - Q (l/min)

V-101 NC

V-201 NC

V-121 NC

Curve valide per corsa efficace > 50% • Curves valid for actual stroke > 50%

SCHEMA IDRAULICOHYDRAULIC DIAGRAM

202

PERDITE DI CARICOPRESSURE DROPS CURVE

13.3 - FINECORSA A PULSANTENORMALMENTE CHIUSO13.3 - PUSHBUTTOM END STROKE VALVES,NORMALLY CLOSED

IMPIEGO:Valvola utilizzata per aprire il passaggio di olio in un circuito idraulico (valvola normalmente chiusa). Una volta azionato meccanicamente il cursore, si ha il libero passaggio dell’olio da P a A. Può avere principalmente due impieghi:a) per azionare la sequenza di due attuatori;b) come valvola di fine corsa, con flusso direttamente collegato

allo scarico.

MATERIALI E CARATTERISTICHE:Corpo: acciaioComponenti interni: acciaio temprato termicamente e rettificatoGuarnizioni: BUNA N standardTenuta: a sfera. Trafilamento nulloCorsa massima del cursore: 13 mmApertura immediata

MONTAGGIO:Collegare P alla linea di utilizzo e A direttamente allo scarico. Lo schema di montaggio può variare in base al servizio richiesto.

USE AND OPERATION:This valve allows oil passage in a hydraulic circuit (normally closed valve). Once the slider is set into action, oil flow is free from P to A. It can be used: a) to set the sequence of 2 actuators;b) as end strokes valve, where flow is directly connected to the

tank.

MATERIALS AND FEATURESBody: zinc-plated steelInternal parts: grounded and hardened steelSeals: BUNA N standardBall type: any leakageMaximum stroke: 13 mmPrompt opening

APPLICATIONS:Connect A directly to the tank and P as for necessity. Mounting scheme can vary according to the use.

TIPO/TYPE

VF-NC

Temperatura olio: 50°C - Viscosità olio: 30 cStOil temperature: 50°C - Oil viscosity: 30 cSt

Page 18: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

13

CODICECODE

SIGLATYPE

PORTATA MAXMAX FLOW

Lt./min

PRESSIONE MAXMAX PRESSURE

Bar

V0827 V – 101 ⅜” NC 40 350

V0828 V – 121 ½” NC 60 350

V0829 V – 201 ¾” NC 100 350

CODICECODE

SIGLATYPE

A – P L L1 L2 L3 L4 L5 L6 L7 H SPESO

WEIGHT

GAS mm mm mm mm mm mm mm mm mm mm Kg

V0827 V – 101 ⅜” NC G ⅜” 80 105 35 10 55 30 14 55 50 35 0,962

V0828 V – 121 ½” NC G ½” 80 105 35 10 55 28,5 14 55 50 35 0,934

V0829 V – 201 ¾” NC G ¾” 88 115 50 20 68 23 14 61 70 45 0,860

SA

L5

L4

P

L7

L L6

L1

L2 H

8,5

L3

foro non fornito su V-201 3/4"

V-201 3/4" is supplied without hole

203

Page 19: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

A

P

0

0,5

1

1,5

2

2,5

3

0 10 20 30 40 50 60 70 80 90

FLOW - Q (l/min)

Curve valide per corsa efficace > 50% • Curves valid for actual stroke > 50%

V-101 NA V-121 NA

∆P

(Bar)

P A

SCHEMA IDRAULICOHYDRAULIC DIAGRAM

204

PERDITE DI CARICOPRESSURE DROPS CURVE

13.4 - FINECORSA A PULSANTENORMALMENTE APERTO13.4 - PUSHBUTTOM END STROKE VALVES,NORMALLY OPENED

IMPIEGO:Valvola utilizzata per chiudere il passaggio di olio in un circuito idraulico (valvola normalmente aperta). La chiusura della valvola è ottenuta spingendo meccanicamente il cursore.

MATERIALI E CARATTERISTICHE:Corpo: acciaioComponenti interni: acciaio temprato termicamente e rettificatoGuarnizioni: BUNA N standardTenuta: trafilamento trascurabileCorsa massima del cursore: 15 mmChiusura dopo 4 mm di corsa

MONTAGGIO:Collegare A e P indifferentemente al distributore e al circuito. Quando il cursore è azionato il flusso è bloccato in entrambe le direzioni, viceversa il flusso è libero.

USE AND OPERATION:This valve is used to block oil passage in a hydraulic circuit (normally opened valve). The valve closes by pushing mechanically the slider.

MATERIALS AND FEATURESBody: zinc-plated steelInternal parts: grounded and hardened steelSeals: BUNA N standardBall type: minor leakageMaximum stroke: 15 mmClosing after 4 mm stroke

APPLICATIONS:Connect independently A or P to the distributor and to the circuit. When slider is operating flow is blocked in both direction, vice versa it is free.

TIPO/TYPE

VF-NA

Temperatura olio: 50°C - Viscosità olio: 30 cStOil temperature: 50°C - Oil viscosity: 30 cSt

Page 20: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

13

CODICECODE

SIGLATYPE

PORTATA MAXMAX FLOW

Lt./min

PRESSIONE MAXMAX PRESSURE

Bar

V0817 V – 101 ⅜” NA 35 350

V0818 V – 121 ½” NA 50 350

CODICECODE

SIGLATYPE

A – P L L1 L2 L3 L4 L5 L6 H SPESO

WEIGHT

GAS mm mm mm mm mm mm mm mm mm Kg

V0817 V – 101 ⅜” NA G ⅜” 80 129 35 8 45 30 24 56 35 1,24

V0818 V – 121 ½” NA G ½” 80 129 35 8 45 30 24 62 35 1,38

S

A

L4

P

L5

L L6

L1

L2 H

L3

8,5

Corsa max 15 mmInizia a chiudere dopo4 mm di corsa

205

Page 21: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

14

GIUNTI GIREVOLI

Page 22: MARCHESINI OLEODINAMICA VALVES CATALOGUE PART5

SCHEMA IDRAULICOHYDRAULIC DIAGRAM

208

14.1 - GIUNTI GIREVOLI IN LINEA14.1 - IN LINE ROTATING COUPLING

IMPIEGO:Valvole che trovano applicazione tra un tubo flessibile e una parte rigida per compensare rotazioni e torsioni del tubo senza che questo venga danneggiato. Non sono idonei per rotazioni veloci e continuative. Vengono utilizzati in tutti i settori produttivi dove vi siano impianti dotati di tubi flessibili in movimento. Il montaggio è in linea.

MATERIALI E CARATTERISTICHE:Corpo: acciaio zincatoTenuta: tramite guarnizioni a basso attrito

MONTAGGIO:Collegare le bocche P agli utilizzi.

A RICHIESTA:• Filetto NPT (codice di ordinazione GN… anziché G...

es. codice GGL ¼” NPT = GN1050)

USE AND OPERATION:These valves are mounted between the end of a flexible hose and a fixed component to compensate hose’s rotations and torsions and to prevent its damaging. They are not suitable for fast and continuous rotations. They are used in every production field where systems have flexible moving hose. In line mounting.

MATERIALS AND FEATURES:Body: zinc-plated steelTightness: low friction seals

APPLICATIONConnect ports P to the uses.

ON REQUEST• NPT thread (code GN… instead of G...

example: GGL ¼” NPT code = GN1050)

TIPO/TYPE