Description – Short-circuit protection – Disconnect function – Suitable for three- and single-phase application – Trip-free mechanism – Clear switch position indication ON/OFF/TRIP – Lockable handle Order data MO132 screw terminal Rated operational current A Type Trip class Order code Pack- ing unit PCE Weight per PCE kg 0.16 MO132-0.16 - 1SAM360000R1001 1 0.215 0.25 MO132-0.25 - 1SAM360000R1002 1 0.215 0.40 MO132-0.4 - 1SAM360000R1003 1 0.215 0.63 MO132-0.63 - 1SAM360000R1004 1 0.215 1.00 MO132-1.0 - 1SAM360000R1005 1 0.215 1.60 MO132-1.6 - 1SAM360000R1006 1 0.265 2.50 MO132-2.5 - 1SAM360000R1007 1 0.265 4.00 MO132-4.0 - 1SAM360000R1008 1 0.265 6.30 MO132-6.3 - 1SAM360000R1009 1 0.265 10.0 MO132-10 - 1SAM360000R1010 1 0.265 12.0 MO132-12 - 1SAM360000R1012 1 0.310 16.0 MO132-16 - 1SAM360000R1011 1 0.310 20.0 MO132-20 - 1SAM360000R1013 1 0.310 25.0 MO132-25 - 1SAM360000R1014 1 0.310 32.0 MO132-32 - 1SAM360000R1015 1 0.310 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short- circuit. Fuse less protection with a manual motor starter saves costs, space and ensures a quick reaction under short- circuit condition, by switching off the motor within milliseconds. Fuse less starter combinations are setup together with contactors and overload relays. Manual motor starter magnetic only MO132 Data sheet 2CDC241009S0011
9
Embed
Manual motor starter magnetic only MO132 - ABB Ltd · Manual motor starter magnetic only MO132 Data sheet 2CDC241009S0011. 2 - 2CDC131035D0201 Functional description 2CDC241009S0011
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Description – Short-circuit protection – Disconnect function – Suitable for three- and single-phase application – Trip-free mechanism – Clear switch position indication ON/OFF/TRIP – Lockable handle
Order data
MO132 screw terminal
Rated operational current
A
Type Trip class
Order code Pack-ing unit
PCE
Weight per PCE
kg
0.16 MO132-0.16 - 1SAM360000R1001 1 0.215
0.25 MO132-0.25 - 1SAM360000R1002 1 0.215
0.40 MO132-0.4 - 1SAM360000R1003 1 0.215
0.63 MO132-0.63 - 1SAM360000R1004 1 0.215
1.00 MO132-1.0 - 1SAM360000R1005 1 0.215
1.60 MO132-1.6 - 1SAM360000R1006 1 0.265
2.50 MO132-2.5 - 1SAM360000R1007 1 0.265
4.00 MO132-4.0 - 1SAM360000R1008 1 0.265
6.30 MO132-6.3 - 1SAM360000R1009 1 0.265
10.0 MO132-10 - 1SAM360000R1010 1 0.265
12.0 MO132-12 - 1SAM360000R1012 1 0.310
16.0 MO132-16 - 1SAM360000R1011 1 0.310
20.0 MO132-20 - 1SAM360000R1013 1 0.310
25.0 MO132-25 - 1SAM360000R1014 1 0.310
32.0 MO132-32 - 1SAM360000R1015 1 0.310
Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short-circuit. Fuse less protection with a manual motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by switching off the motor within milliseconds. Fuse less starter combinations are setup together with contactors and overload relays.
Manual motor starter magnetic only MO132Data sheet
2CD
C24
1009
S00
11
2 - 2CDC131035D0201
Functional description2C
DC
2410
09S
0011
1
2
3
4
5
1 Terminals 1L1, 3L2, 5L3
2 Switch position TRIP
3 Lockable handle
4 Test function
5 Terminals 2T1, 4T2, 6T3
Application
The manual motor starters magnetic only protect the load and the installation against short-circuit. They are three pole protection devices with electromagnetic tripping elements for short-circuit protection. Furthermore, they provide a disconnect function for safely isolation of the installation and the supply and can be used for the manual switching of loads.
For overload protection of the motors, an appropriate thermal or electronic overload relays must be used.
Operation mode
I> >I >I
1~
2CD
C24
2003
F001
1
Single-phase operation
I> >I >I
3 ~
2CD
C24
2004
F001
1
Three-phase operation
Wiring diagram
1L1 3L2 5L3
2T1 4T2 6T3
2CD
C24
2009
F001
1
2CDC131035D0201 - 3
Power loss per pole
Type Power loss per pole
W
MO132-0.16 1.7
MO132-0.25 1.7
MO132-0.4 1.7
MO132-0.63 1.7
MO132-1.0 1.7
MO132-1.6 1.7
MO132-2.5 1.7
MO132-4.0 0.7
MO132-6.3 1.1
MO132-10 2.2
MO132-12 1.7
MO132-16 1.9
MO132-20 2.1
MO132-25 2.2
MO132-32 3.1
Dimensions
in mm / inches
75 /
2,95
"
1,7
/ 0,1
"
1,5 / 0,06"
90 /
3,54
"
14 / 0,55"
45 / 1,77"
14 / 0,55"
72,4 / 2,85"
81,25 / 3,2"
45 /
1,77
"
5,5 / 0,22" 43,5 / 1,71"
35 /
1,38
"
mm / inch
2CD
C24
2005
F001
1
MO132 ≤ 10 A
45 /
1,77
"
35 /
1,38
"
1,5 / 0,06"
75 /
2,95
"1,7
/ 0,1
"
97,8
/ 3,
85"
14 / 0,55" 14 / 0,55"
45 / 1,77"
5,5 / 0,22" 43,3 / 0,22"
72,2 / 2,84"
81,05 / 3,19"
mm / inch
2CD
C24
2006
F001
1
MO132 > 10 A
9 / 0,35"Ø 4,5 / Ø 0,18"
110
/ 4,3
3"
122
/ 4,8
"
17,5 / 0,69"
5,4 / 0,21"
mm / inch
2CD
C24
2007
F001
1
MO132 ≤ 10 A with screw fixing kit FS116 (accessory)
5,4 / 0,21"9 / 0,35" Ø 4,5 / Ø 0,18"
110
/ 4,3
3"
122
/ 4,8
"
17,5 / 0,69" mm / inch
2CD
C24
2008
F001
1
MO132 > 10 A + with screw fixing kit FS116 (accessory)
4 - 2CDC131035D0201
Technical data IEC/EN
Data at TA = 40 °C and at rated values, if nothing else indicated
Main circuit
1L1-3L2-5L3
2T1-4T2-6T3
Rated operational voltage Ue 690 V AC
-
Rated operational current Ie see table below
Rated operational current DC-5
3 conducting paths in series up to 250 V
-
Rated instantaneous short-circuit current setting Ii see table below
Rated service short-circuit breaking capacity Ics see table “Short-circuit breaking capacity and back-
up fuses” on page 6Rated ultimate short-circuit breaking capacity Icu
Rated frequency 50/60 Hz
Number of poles 3
Power loss per pole see table “Power loss per pole” on page 3
You can find the address of your local sales organization on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems
Contact us
Note:We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.
We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG.