Top Banner
IP2006 rev. 2008-12-18 CROSS3E/5EH/7EH - 73R QUICK REFERENCE 1. ELECTRICAL CONNECTIONS FOR STANDARD INSTALLATION Before installing the product, carefully read the instructions. XEL5 XEL2 TX XEL2 RX 01 4x0,5 mm² 3x1,5 mm² ANT 4x0,5 mm² 4x0,5 mm² 01 C NO NC Power supply RG58 (max 10 m) 14 0 2x1,5 mm² CROSS3E CROSS5EH CROSS7EH 73R 14 C NO 13 12 0 11 1 1 5 6 8 9 2041 GOL4-GOL4C LAMPH F1 L N
4

Manual motor puerta corredera

Mar 22, 2016

Download

Documents

jmghera

Manual de un motor puerta corredera
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Manual motor puerta corredera

IP2006 rev. 2008-12-18

CROSS3E/5EH/7EH - 73R QUICK REFERENCE

1. E

LEC

TRIC

AL

CO

NN

ECTI

ON

S FO

R S

TAN

DA

RD

INST

ALL

ATIO

N

Bef

ore

inst

allin

g th

e pr

oduc

t, ca

refu

lly re

ad th

e in

stru

ctio

ns.

XEL5

XEL2

TXXE

L2R

X

01

4x0,5 mm²

3x1,5 mm²

AN

T

4x0,5 mm²

4x0,5 mm²

01

CNO NC

Pow

er s

uppl

y

RG58 (max 10 m)

140 2x1,5 mm²

CRO

SS3E

CRO

SS5E

HCR

OSS

7EH

73R

14C

NO13

120

111

15

68

920

41

GO

L4-G

OL4

C

LAM

PH

F1

LN

Page 2: Manual motor puerta corredera

2CROSS3E/5EH/7EH-73R QUICK REFERENCE - IP2006

2. LIMIT SWITCHES CONNECTION FOR CROSS5EH - CROSS7EH ONLY (OPTIONAL)

Adjust the limit switch brackets! Adjust the limit switch brackets!

FCMCRFCMCR

12 011

Remove the bridges!

Connect the limit switches!

12 011

Page 3: Manual motor puerta corredera

3 CROSS3E/5EH/7EH-73R QUICK REFERENCE - IP2006

3.1 USAGE WITHOUT LIMIT SWITCHES

3.2 USAGE WITH STOP LIMIT SWITCHES (OPTIONAL)

DIP2=OFF

AOpening limit switch setting

CClosing limit switch setting

- + VA opening speed setting

- + VC closing speed setting

Slow down speed

DIP2=ON

AOpening limit switch setting

CClosing limit switch setting

- + VA opening speed setting

- + VC closing speed setting

Slow down speed

DIP2=OFF

- + VA opening speed setting

- + VC closing speed setting

Slow down speed

OPENING CYCLE

CLOSING CYCLE

CLOSINGMECHANICAL STOP

OPENINGMECHANICAL STOP

OPENING CYCLE

OPENING CYCLE

CLOSING CYCLE

CLOSING CYCLE

A

AC

C

OPENING MECHANICAL STOP

CLOSINGMECHANICAL STOP

CLOSING CYCLE

OPENINGCYCLE

DIP2=ON

- + VA opening speed setting

- + VC closing speed setting

Slow down speed

Page 4: Manual motor puerta corredera

4CROSS3E/5EH/7EH-73R QUICK REFERENCE - IP2006

5. RADIO ENABLING

4. 73R STANDARD SETTING

i For different setting and further information consult the CROSS3E, CROSS5EH, CROSS7EH automation instruction manual, the 73R control panel instruction manual and BIXLR22 radio instruction manual.

DITEC S.p.A.Via Mons. Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALYTel. +39 02 963911 - Fax +39 02 9650314 www.ditec.it - [email protected]

6. AUTOMATIC CLOSING SETTING

- +

TC time settingDISABLED!

MAX

- +

TC time setting ENABLED!

MIN=0 s MAX

120 s

MIN=0 s MAX

120 s

VA VC TC R1

6 4

20 2

NIO1 2 3 4 5

C NO 0 1 1 5 6 8 9 20 4114 13 12 11

SO JR4

JR3

ON

OFF

DIP1 = ON

DIP2 = ON

OPENING RADIO MODE

LEFT OPENING

DIP2 = OFF RIGHT OPENING

DIP1 = OFFSTEP BY STEP RADIO MODE

GOL4-GOL4C

Wait for 10 s

SIG

Push PRG

Led SIG comes on

Push CH

SIG

Led SIG flashes 3 times

1° 2°

SIG

NIO

PRG

JR3