IP65. To 1034 kPa (150 psi). For use with battery-operated indicators e.g. FRT303-B, ME5-T-B as per fitting
RPFS-L
RPFS-LO Rota Pulse Flow Sensor, inbuilt op-amp for dataloggers, 50C (M12 -5m lead + lockcap) IP65., 3-24vdc, To 1034 kPa
as per fitting
RPFS-LO
RPFS-LOD Rota Pulse Flow Sensor, contact closure pulse, 110C (M12 -5m lead +lockcap) Ideal for datalogger apps switching 0-100vDC pwr. (ideal for battery pwr apps.) Self powered with no current draw when connected to input devices.
as per fitting
RPFS-LOD
RPFS-H-LS Rota Pulse Flow Sensor, LONG STEM (for pipes ≥ 120mm Φ) . NPN pulse output, (2m lead + lockcap). IP65. 5-30VDC powered. For use with liquids up to 50ºC. To 2000 kPa (300 psi).
as per fitting RPFS-H-LS
RPFS-L-LS Rota Pulse Flow Sensor, LONG STEM for pipes ≥ 120mm.
inductive coil pulse o/p, 120C (2m lead + lockcap). IP65. To 2000 kPa (300 psi).
For use with battery-operated indicators e.g. FRT303-B, ME5-B etc
as per fitting
RPFS-L-LS
For use with any Remote Batch Controllers Display Indicators: ME995-7, ME3000, FRT303, ME5 or with practically any logic pulse input device
Adapt into pipes using ManuFlo’s various pipe adaptor options
Long stem version for adapting to larger pipe diameters Match with “-LS” pipe adaptors
Prices and specifications may change without notice. ManuFlo CATALOGUE 2019-20 v1.0 ManuFlo ®™
See www.manuelectronics.com.au for product data sheets. All prices in AUD$, and exclude GST 5
PIPE ADAPTER FITTINGS & ACCESSORIES for all MRTU & RPFS FLOWMETER slip insertion models (continued)
Order Code Description Tapping Band SADDLE CLAMPS –(pipe hole cutout size is 32mm) Pipe OD
mm
Pulses
Litre (1)
Discount.
1-9 10+
Flowrange
Litres/Min(2)
4N Tapping saddle bands Used on series 1 PVC pipe AS/NZ-4793 –glass re-enforced Beige color plastic with NBR gasket E-lip seal (requires low bolt torque, 316 S/S bolts/nuts (x2).
PPL
for I.D.
PVC40SC 40mm (1½") Saddleclamp adapter with keyway for PVC series 1 pressure pipes to PN16 48 30 50 - 640 Saddle fitted to pipe PVC50SC 50mm (2”) “ “ “ “ “ 60 20 90 - 980
4N Tapping saddles Used for Ductile Iron, AC & series 2 PVC pipe –glass re-enforced Blue color plastic with NBR gasket E-lip seal (requires low bolt torque, 316 S/S bolts/nuts .x2)
PVC100SC-2 100mm (4”) Saddleclamp keyway adapter for PVC series 2 pressure pipes to 1500 kPa. 122 4.6 300 - 4005
PVC150SC-2-LS 150mm (6”) Saddleclamp adapter for PVC series 2 pressure pipes to 1500 kPa. (Long Stem) 177 2.1 600 - 9010 PVC100SC-2
4N Tapping bands Used for Metric Irrigation PE pipe AS4130 –glass re-enforced Black color plastic with NBR gasket E-lip seal (requires low bolt torque, 316 S/S bolts/nuts .x2)
SCPE63 63mm Saddle clamp (metric PE pipe) adapter with keyway insert polypropylene pipe sections 63 11.7 132 - 1580
BSPB-LS Long Stem 1”BSP-m Brass Adapter nipple with locating key & locknut, for larger pipe sizes 125mm>. I.D. (Note 2)
BSPB-LS
BSOC Brass socket (Adapter nipple screws into socket, which is welded to pipes. For 40-500mm Ø pipes).
APPLICATION NOTES:-
All adaptor fittings are prefitted with ManuFlo patented Keyway insert adaptor and postioned at correct depth for capture of flows for the given
pipe diameter to suit the MRT/RPFS insertion flowmeter range.
For Manuflo to inhouse calibrate the MRT flowmeter or provide PPL for RPFS, then whilst ordering provide the internal diameter (I.D) of the pipe.
NOTE: Sizes 80mmΦ & above incur a surcharge if requiring a NMI-NSS1671 calibration on the ManuFlo Flow-rig.
PVC PVC slip keyway adaptor tees used with PVC-U pressure pipes – pipes are glued into the adaptor tees onsite.
All MRP/MRT units are calibrated to PN12 PVC pipe diameters upto 100mm.
GAL GAL galvanised iron adaptor keyway tees have BSP threaded connections ideal for use with galvanised pipe sections, also suitable for any form of pipe that can be adapted to the tee of similar size or larger.
SS SS 316 stainless steel adaptor keyway tees – pipe connection options as above.
PVC-SC / SC2
SCPE / SC
Saddle Clamps
A range of Saddleclamp adaptor fittings are prefitted with ManuFlo patented Keyway adaptor insert to capture pipe flows.
To select the correct saddle size check the OD of the pipe that the saddle is to be fitted to.
To fit saddles, you must cut hole size diameter of 32mm, the adaptor nipple then drops into pipe cutout and should sit
approx. 5-10mm past the ID curvature of the pipe. (DO NOT lose seal gasket, overtighten bolts or fit on the underside of pipe).
Formula PPL for ManuFlo paddlewheel flowmeters (Models: RPFS, MRP, MRT)
Pulses Per Litre for a given pipe diameter Constant = 46,512 ÷ (pipe I.D. in mm)2
Example:- Pulses Per Litre for 200 mm I.D. pipe
Therefore 46,512 ÷ (200)2 = 46,512 ÷ 40,000 = 1.2 Pulses/Litre (this figure is then computed into the K-factor)
-IR option: Internal Reset. Total is reset via internal pushbutton instead of the round button on the face. ME5-T-B
ME5-F FLOWRATE LCD Indicator – Order Codes ME5-T TOTALISER LCD Indicator – Order Codes
Nominate at time of order: Mls, Litres, KL or ML per Sec., Min., or Hours. Nominate at time of order: Mls, Litres, KL or ML. with 0, 1 or 2 decimal places.(Refer to datasheets) TECHNICAL Note: When ME5 & FRT303 units are 240vac configured, volt. Supply to flowmeter is 12VDC. When configured as 5-24VDC pwrd units the volt. supply to NPN flowmeters is proportionally the same.
FRT303 / ME5: Suitable with RPFS range slip insertion rotor flowmeters (most flowmeters) to suit remote display applications.
-T Teflon-lined body. Add suffix to any 20mm MES-type flowmeter order code.
Barrel Union connectors also available. # The flowrange is for 1.5% accuracy. Can measure outside this flowrange, but at reduced accuracy; Flowrange is for water. For Admix flowrange, divide water flowrate by the Admix sg. At ±5% accuracy, MES flowmeters can measure down to: 20mm: 0.5 Litres/min; 25mm: 1.0 L/m; 32mm: 1.5 L/m; 40mm: 2.8 L/m; *with water and light chemicals.
-T Teflon-lined body. Add suffix to any 20mm MES-type flowmeter order code. MES25M
# The flowrange is for 1.5% accuracy. Can measure outside this flowrange, but at reduced accuracy; Flowrange is for water. For Admix flowrange, divide water flowrate by the Admix sg.
(1) At ±5% accuracy, MES flowmeters can measure down to: 20mm: 0.5 Litres/min; 25mm: 1.0 L/m; 32mm: 1.5 L/m; 40mm: 2.8 L/m;
Prices and specifications may change without notice. ManuFlo CATALOGUE 2019-20 v1.0 ManuFlo ®™
See www.manuelectronics.com.au for product data sheets. All prices in AUD$, and exclude GST 13
1.4.4 MES-LCD4 / MES-LCD6 Flowmeters – DUAL DISPLAY Flowrate &/or Resetable Total - widely used for Admixtures Ideal for Precision Batching applications.
Closing the lid resets the display total.
Measures liquids to Specific Gravity 1.4
Nutating disc P.D. measuring chamber.
Small Impurities can pass through measuring chamber without jamming.
Low hydraulic thrust minimises wear.
Internal Lithium battery (10+ year battery life) Acurate: ± 1.5% full scale flowrange (unaffected by SG)
Repeatability: ± 0.2%
Maximum working pressure: 1160 kPa
Maximum liquid temperature: 50 °C
Connection: 20, 25 & 32 mm : threaded BSP(m) 40 mm : flanged BSP(f)
NEW FEATURES:
4 digit resettable total with EXTRA LARGE Digits or
6 digits total in Litres (L) or KiloLitres (KL) up to 3 decimal place and rate in Litres per minute (L/M) or Litres per second (L/S) with 1 dec.place. (specify which at time of ordering)
-T Tefzel-lined body. Add suffix to any 20mm MES-type flowmeter order code.
NFC.A Re-calibration software with AGM8-Phone-strong NFC signal (or download install free on Andriod)
-LPS Flowrate in Litres/sec in lieu of LPM
-NRNS No reset of total (running accumulative totaliser & permanently on).
# The flowrange is for 1.5% accuracy. Can measure outside this flowrange, but at reduced accuracy. Flowrange is for water. For Admix flowrange, divide water flowrate by the Admix sg. (1) At ±5% accuracy, MES flowmeters can measure down to: 20mm: 0.5 Litres/min; 25mm: 1.0 L/m; 32mm: 1.5 L/m; 40mm: 2.8 L/m;
-P Programmable pulse output. M12 socket, plug and 5-metres cable. (1p/1ltr or 1p/0.1ltr)
Display reading options:-
Flowrate with 1 or 3 decimal places in Litres/min (LPM) or Litres/sec. (LPS)
Reset total in Litres (L) or with 1 dec.pl (DP),
Grand total in Litres (L) or KiloLitres (KL) to 1 dec.pl.
Optional Pulse output 0.1 Litre or 1 Litre per pulse.
Nominate desired display setup at time of ordering for ManuFlo preprogramming.
# The flowrange is for 1.5% accuracy. Can measure outside this flowrange, but at reduced accuracy. Flowrange is for water. For Admix flowrange, divide water flowrate by the Admix sg. (1) At ±5% accuracy, MES flowmeters can measure down to: 20mm: 0.5 Litres/min; 25mm: 1.0 L/m; 32mm: 1.5 L/m; 40mm: 2.8 L/m;
Prices and specifications may change without notice. ManuFlo CATALOGUE 2019-20 v1.0 ManuFlo ®™
See www.manuelectronics.com.au for product data sheets. All prices in AUD$, and exclude GST 15
1.4.6 MES20-S & -S-T with Ryton MTL chamber / Teflon coated body for Low.PH-chemicals and petroleum liquids. Widely used for Admixtures and aggressive chemicals, ideal for oil/petrol products.
Ryton-MTL special Hi-chemical/petroleum-resistant measuring chamber, high chemical resistance ceramic-bar. magnet, black Nylon glass filled drive shaft and viton seals.
Measures liquids to Specific Gravity 1.5
Nutating disc measuring principle.
Small Impurities can pass through measuring chamber without jamming.
Low hydraulic thrust minimises wear.
Maximum working pressure: 1160 kPa.
Teflon-lined version for corrosive liquids. Connection: threaded ¾” BSP (male)
Order Code Size – Bsp(m) Accuracy Specific Gravity >= 1.1 Display Display shows Resetable Temp Litres/min
MES20-S 20 or 25 mm ± 1.5% 900-1000 ppL Digital No n/a 60 °C 5 – 75
MES20R-S 20 or 25 mm ± 1.5% 54-60 ppL ReedSwitch No n/a 80 °C 5 – 75
MES20-S-T 20 or 25 mm ± 1.5 % 900-1000 ppL Digital No n/a 50 °C 5 - 75
MES20LCD4DP-S 20 or 25 mm ± 1.5% n/a 4-digit LCD Litres, to 1 decimal place Yes 50 °C 5 – 75
MES20LCD6DP-S 20 or 25 mm ± 1.5% n/a 6-digit LCD Litres 1 dec.pl +rate LPM Yes 50 °C 5 – 75
OPTIONAL TEFLON / TEFZEL COATED LINING All models with Standard Ceramic or Ceramic/Barium Magnet
-T Tefzel-lined body (green) or Teflon(black) for corrosive chemicals.
Add suffix to flowmeter order code.
* Note: pulse output rate is different for liquids with Specific Gravity < 1.1 e.g. for s.g = 1.0, pulse output rate is up to 10% less than that for s.g. 1.1
MES20-S (yellow body) (Transistor Pulse output,
chemically resistant chamber)
MES20-S-T (Black Body) (Teflon-coated pulse o/p,
chemically resistant chamber)
MES20-S-T (Green Body)
(TEFZEL coated) MES20LCD6
Flowrate + Resetable Total
-S Ryton MTL Chamber (Shown with viton or EDPM gaskets&
Teflon spacer)
. Flowrange is for water. For Admix flowrange, divide the water flowrate by the Admixture’s Specific Gravity. PULSE RATE PER VOLUME VARIES SO METER MUST BE ONSITE CALIBRATION CHECKED.
2A Meter body (coupling-free, ¾” BSP male connection), without chamber 3 Strainer 5 Measuring chamber (complete with gasket body seal)
ceramic-barium magnet c/w plastic shroud
6 Chamber O ring
7 Base sealer gasket ring -rubber 7E Base sealer gasket ring -EDPM
8 Base plate Synthetic Polymer plastic 8P Base plate (PVC) –for higher acidic liquids
8M Base plate (cast iron) } with Nylon inner cover plate (suits –S and –T) 9 Stainless 316 base screw 11 Nut/Tail/Gasket connection kit(pair)-for old body only (metric) 12 Connection washer (each) - for old body/gasket only 13 Oval flange kit (pair) BC Chamber and New Body (parts 2A - 7, 8M and 9 above) SBU Barrel Connection Unions –Polyprop –BSP(f) -comes as a pair
NOTE : NEW “ –N “ version compact low profile body and chamber for MES20 20mm sizes (top capsule is interchangeable)
OGF80 80mm (3”) Pulse output or mechanical resettable total + running total 2.65 “ “ “ 35 - 750
-MR Mechanical Register Type for sizes 15-80mm (replaces blind pulse register) Connection:-
-SS S/S-316 body in lieu of aluminium Sizes 04 to 80mm is BSP-F threaded, Flanged options available.
-EGM NPN higher rate pulses available
-ER LCD electronic display module Recommend a filter installed prior to OGF flowmeters
-ISR INTRINSICLY SAFE Rated options
Pressures from 20-40bar ranges. To 120c Temp., PPS rotors and Viton seals supplied as standard. Ceramic carbide shafts. Intrinsic safe options available on request.
1.6 GT series - Turbine flowmeters. LCD resettable & or pulse (for Chemicals, Fuels, , Solvents with <100cps)
Order Code Description Pls/Ltr. Aluminium S/S-316 LCD Display (Litres/min.)
Prices and specifications may change without notice. ManuFlo CATALOGUE 2019-20 v1.0 ManuFlo ®™
See www.manuelectronics.com.au for product data sheets. All prices in AUD$, and exclude GST 19
1.8 PSM domestic water flowmeter Compliance with NMI R49-1 Australian Standards AS3565.1 – Pattern Approved
Designed for the measurement of cold potable water.
Accurate; long maintenance-free life; highly resistant to tampering.
For pipe diameters from 15 to 40 mm.
Optional pulse output (via T-probe).
Cannot be disassembled whilst in service and the mechanically driven counter cannot be interfered with magnetically. A lead seal will reveal any attempt to dismantle the meter.
Positive displacement volumetric rotary piston principle of measurement ensures registration even at the very lowest rates of flow with accuracy maintained over the flow range.
No calibration required throughout its lifespan.
A large surface area fine filter fitted on the measuring chamber inlet prevents damage by gathering solid particles. A partially obstructed filter will not affect the meter’s accurate registration.
Shows total in KiloLitres and Litres.
Mechanically driven number counter.
Maximum registration 99999.999 kL
(for 5x3 number wheel counter models).
± 2% accuracy. ± 0.15% repeatability. (Start 5%)
Advanced engineering plastics measuring chamber.
Pulse output option (can be retro-fitted).
Max. Operating Temp: 50 ºC.
Max. Operating Pressure: 1400 kPa.
15-25mm models supplied with Gasket Seat couplings.
32-40mm models supplied with flange kits.
Gunmetal Body Construction.
Supplied with Flanged. Gasket Seat couplings.
Flowrange (Litres/min) *
Order Code Description Connection Start Min. Max. Max.
to 30 C (to 50 C for < 2 hours). Accuracy: ± 2%, Repeatability of rate ± 0.1%. 1500kPa
With single check valve. Couplings included - Gasket Seat 1” BSP(m)
0.4 - 116
CT5-S25
Manifold Type Models:-
CT5-S20-M-15 Manifold flowmeter 121ppl. SCV e.g. for NZ-Water etc (with 15mm flow range). G 1½” thread. 0.1 - 50
CT5-S20-M-20 Manifold flowmeter 72ppl. DCV e.g. for QLD-Water & others (20mm flow range) G 1½” thread. 0.2 – 83
MCT20-NZ Manifold coupling cast. G 1 ½”-BSP-F with 20mm ¾” BSP (male) ends –(by DataCol / Accuflo)
MCT20 Manifold coupling cast. G 1 ½”-BSP-F with 20mm ¾” BSP (male) ends –(by StrongCast)
CT5-S Client supplies the standard mechanical totaliser flowmeter to ManuFlo, ManuFlo converts flowmeters with high pulserate technology option
CT5-S20-M-20 CT5-S20-M-15
Optionals:-
-BS20/25 20/25mm BSP female Ball Seat connection for NSW (in lieu of Gasket Seat connections)
-DCV Dual Check valve MCT20 MCT20-NZ
Used in Water Studies in Australia, Germany, Iran, NZ, UAE and other locations inconjunction with a Datalogger capable of 100Hz+ input count range.
1.10 Data Loggers ME-USB-5+ Counter, Event and State USB Data Logger. 1 event count input (not scaleable).
Volt-free normally open contacts, or input voltages up to 24 VDC.
Stores up to 1,000,000 timed events/intervals in counter mode.
With internal 1yr Lithium.bat. 3.6v 1/2AA, Windows control software & measurement leads.
Suitable for low pulse resolution flowmeters e.g. 1 pulse per 1 Litre, (or e.g. 5, 10,100,1000 ltrs).
Loggers ManuFlo flowmeters connect to loggers with GSM, SPRS, SMS and Control emailed data collection with Web Portal options. Manuflo recommendations include:-
Prices and specifications may change without notice. ManuFlo CATALOGUE 2019-20 v1.0 ManuFlo ®™
See www.manuelectronics.com.au for product data sheets. All prices in AUD$, and exclude GST 21
1.11 S100 90C HOT WATER flowmeters, with optional pulse output Order Code Description (Accuracy ±2%, to 90C) Single-jet turbine water flowmeter; to 16 bar Flowrange* (L/min)
For Larger Sizes 20,25,32,40 and 50mm ask for MBH model flowmeter range (with optional pulse output). POA *starts are at reduced accuracy.
1.12 WP-D Turbine water flowmeters, mechanical total, optional pulse output ideal for measurement of high relatively constant flow rates e.g. behind pumps
hermetically sealed register (IP68) can be rotated through 360°
Range exceeds of the Australian Standard AS 3565.1 Measurement Class 2 requirements.
Usually ex-stock items. AUSTRALIAN PATTERN APPROVED FLOWMETERS FROM GERMANY
accuracy: ±2%
To 1600 kPa. To 50 C.
Table D flanged.
ME5-T-B Remote IP65 LCD bat.pwr reset counter with Scalable input
Flowrange (L/min)
Order Code Description min ±5% min ±2% max ±2% WP-D40 40 mm running mechanical Totaliser 10 or 100 litres/pulse with RD10. 4 7.5 666
WP-D50 50 mm “ “ “ “ “ 5 11.7 833
WP-D65 65 mm “ “ “ “ “ 6.7 13.3 1167
WP-D80 80 mm “ “ “ “ “ 8.3 13.3 2000
WP-D100 100 mm “ “ “ “ “ 13.3 30.0 3833
WP-D150 150 mm “ 100 or 1000 litres/pulse with RD10 30.0 50.0 5500
MEH50-F 50 mm turbine flowmeter, running mechanical Totaliser, Table D flanged 15 35 800
MEH80 80 mm turbine flowmeter, running mechanical Totaliser, Table E flanged 25 133 2000
MEH100 100 mm “ “ 35 200 3333
MEH150 150 mm “ “ 75 500 5000
MEH200 200 mm “ “ 125 833 8333
MEH250 250 mm “ “ 200 1333 13333
MEH300 300 mm “ “ 300 2000 25000 MEH80
-RS Reed Switch pulse module, for MEH sizes 15 to 50mm (can be retrofit to flowmeters)
Flowmeters with Pulse o/p are suitable for use with ManuFlo® Wall mount IP65 Resetable LCD (pulse input scalable) counter indicators bat.pwr e.g., ME5-T-B or ME6
NOTE: NOT IDEALLY SUITABLE FOR CONNECTION TO LCD FLOWRATE INDICATIORS DUE TO LOW RESOLUTION PULSE RATES
Robust alloy housed integral mounted electronics 8732E-AX with toughened glass face.
With LCD Display Module (-M4) shows dual line flowrate & accumulative or resettable totaliser. Repositionable in 90 degree angle steps to suit install. (Programmable to desired engineering units).
All units pre-programmed to desired settings, prewired and flow tested, ready for install.
WAFER (8711) HIGH PRESSURE SENSOR FOR GROUT to 5100kPa. or FLANGED ANSI-150 (8705) sensor with Tefzel or Teflon liner,
Stainless Steel 316 or Hastelloy-C electrodes (With Empty Pipe detection).
Process liquid requires a conductivity of at least 5 microsiemens/cm.
Measures velocity range 0.01 - 10m/s. Accuracy ±0.5% of rate (0.9 to 10 m/s). Liquid temperature: Integral: -20 to 70 ºC, Remote: -20 to 149 ºC for Tefzel liner.
Pressure: 15-150mm wafer sizes to 740 psi (5100 kPa) #8711 HIGH PRESSURE, 4-8mm wafer & 15-150mm flanged sizes #8705 to 290 psi (2000 kPa).
Pulse and 4-20mA outputs. Power supply standard 90-250 vac, or optional 12-42 VDC.
Fully programmable to user specification via HART protocol or -M4 local display.
Approved for Class III Hazardous Applications (NEMA 4x). (Upto 80% solids) Coils set on 30Hz for Grout/oxides/slurries
RMS
8732 transmitter with
8711 wafer sensor
flowmeter
RMS wafer sensor flowmeter with M4 LCD display,
with earthed
PVC flange connection kit
8732E-R remote display/transmitter &
8705 flanged sensor
Flowrange (Litres/min)
Order Code Description
min
(±10%) min
(±5%) min
(±0.5%)
max
(±0.5%)
RMS004 -M4 4 mm Wafer sensor (8711), S/S316 or Hast-C electrodes, Tefzel or Teflon liner, 90-250vac.
with backlit LCD display: dual line flowrate & accumulative or resettable totaliser
0.01 0.02 0.2 6.2
RMS008-M4 8 mm “ “ 0.05 0.1 0.8 25.1
RMS015-M4 15 mm “ “ 0.15 0.4 3.6 107
RMS025-M4 25 mm “ “ 0.5 1.0 10 305
RMS040-M4 40 mm “ “ 1.0 2.5 25 720
RMS050-M4 50 mm “ “ 2.0 4 40 1180
RMS080-M4 80 mm “ “ 4.0 9 90 2616
RMS100-M4 100 mm “ “ 8.0 14 140 4500
RMS150-M4 150 mm “ “ 20 34 341 10225
OPTIONS to order, add as suffix to the RMS flowmeter product code
Prices and specifications may change without notice. ManuFlo CATALOGUE 2019-20 v1.0 ManuFlo ®™
See www.manuelectronics.com.au for product data sheets. All prices in AUD$, and exclude GST 26
1.20 KMS Series. K-MAG Electromagnetic Flowmeters
1.20.1 KMS703 Electromagnetic Internal Battery Powered Flanged Flowmeters with ‘S70’ display with pulse outputs For waste water, bore water, irrigation and liquids on application.
Internal battery powered - ideal for remote locations, or where a external power supply is not available.
Rugged construction with no moving parts – ensures long, maintenance-free flowmeter life.
SJP Sensor Junction Potted for IP68 applications where sensor is located in pit
# The flowrange is for the stated accuracy. Flowmeter can measure below this flowrange, but at reduced accuracy. - PVC/GAL flanged Connection Kits available
Prices and specifications may change without notice. ManuFlo CATALOGUE 2019-20 v1.0 ManuFlo ®™
See www.manuelectronics.com.au for product data sheets. All prices in AUD$, and exclude GST 29
1.20.4 KMS506-S Electromagnetic Flowmeters for Hygeinic Use with ‘S50’ or ‘S100’ Display & Outputs.
Applications include: Exact blending, dosing and batching, Beverages including soft drinks, beer, wine and fruits juices, Milk and other dairy products
K-MAGS Fully wired and custom programmed, ready to use.
PFA (Teflon) liner, Hastelloy C electrodes, Sanitary connections are ‘Tri-clamp’
Prices and specifications may change without notice. ManuFlo CATALOGUE 2019-20 v1.0 ManuFlo ®™
See www.manuelectronics.com.au for product data sheets. All prices in AUD$, and exclude GST 30
1.20.5 KMS101W Electromagnetic Wafer Flowmeters with ‘S100’ display & outputs (ideal as resettable/batching meter)
For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical Applications (upto 20% solids)
K-MAGS Fully wired and custom programmed to requirement.
Polypropylene liner, Hastelloy C electrodes, ANSI 150 lb Flanges
Virtually maintenance free. No moving parts.
Self verifying. Accuracy: ±0.3% +1 mm/s.
85 - 253 vac or 11 - 31 vdc powered
Totaliser up to 8 digits. With Flowrate display.
Totaliser resettable via optional pushbutton.
Display can be Remote (2-metres cable to flowsensor) or Integral (45°or 0° mounted)
Empty pipe detection.
Durable cast alloy display enclosure.
Grounding earth ring supplied.
Programmable via 4 push buttons or via HART to PC.
IP68 remote flow sensor (when potted).
Process temperature: -25 to 120 ºC.
Measured liquid must have conductivity of at least 5 µS/cm (20 µS/cm for water)
(add -R code) Flowrange (Litres/min)
Order Code Description with Integral
Display with Remote
Display min.
(±3%) min
(±0.5%) max
(±0.5%)
KMS101-015W 15 mm Wafer connection, PFA SS reinforced liner, Hast-C electrodes. 85-253vac 0.5 5.3 106
KMS101-025W 25 mm Wafer connection, PFA SS reinforced liner, Hastelloy C electrodes. 85-253vac 1.5 14.7 295
KMS101-040W 40 mm Wafer connection, PFA SS reinforced liner, Hastelloy C electrodes. 85-253vac 10 100 667
KMS101-050W 50 mm Wafer connection, PFA SS reinforced liner, Hastelloy C electrodes. 85-253vac 13 133 1050
KMS101-080W 80 mm Wafer connection, PFA SS reinforced liner, Hastelloy C electrodes. 85-253vac 26 267 2666
KMS101-100W 100 mm Wafer connection, PFA SS reinforced liner, Hastelloy C electrodes. 85-253vac 40 417 4167
KMS101-150W 150 mm Wafer connection, PFA SS reinforced liner, Hastelloy C electrodes. 85-253vac 100 1050 10500
OPTIONS to order, add as suffix to the KMS flowmeter product code
-R Remote wired display/transmitter with 2m cable
-TRB Totaliser Reset Button
-DC 11 - 31 VDC powered.
-XC Extra cable (where n in Product Code = extra cable length in metres)
**Larger flow sensor sizes available on request**
# The flowrange is for the stated accuracy. Flowmeter can measure below this flowrange, but at reduced accuracy. - PVC/GAL flanged Connection Kits available
Measured liquid conductivity as low as 0.05 μS/cm or
1 μS/cm in the case of Demineralised water
Flowrange (Litres/min) #
with min min max
Oder Code Description Integral Display (±2%) (±0.5%) (±0.5%)
KMS307-025W 25 mm, Wafer, Ceramic liner, non wetted electrodes, with Integral ‘S300 CAP’ Display, 85 - 253 VAC 4 30 330
KMS307-040W 40 mm “ “ “ 11 75 905
KMS307-050W 50 mm “ “ “ 14 80 1413
KMS307-080W 80 mm “ “ “ 31 150 3619
KMS307-100W 100 mm “ “ “ 56 250 5655
OPTIONS to order, add as suffix to the KMS flowmeter product code
-TRB Totaliser Reset Button (mounted at cable gland entry)
-DC 11-31 VDC powered
-VR Virtual Reference grounding option for IFC300 (instead of grounding rings on corrosive media)
-316LH S300 Display with 316 L Stainless steel housing
# The flowrange is for the stated accuracy. Flowmeter can measure below this flowrange, but at reduced accuracy. . - PVC/GAL flanged Connection Kits available
Note: These are special meters designed for difficult applications they are not part of our stock inventory therefore must be ordered from the factory with lead time up to 8 weeks.
-R Remote display via 2-metres cable shows flowrate & resettable total
SCS-MM15
-SSB
Dosing Admix System complete.
24VDC powered. (or 12VDC with 12-24VDC step-up voltage converter)
Includes FRT303-D-E-BL-VR24 Flowrate/Totaliser Indicator with backlit LCD display and regulated 24VDC output to
MM15 ½” BSP (male) electromagnetic flowmeter to 1600 kPa (16 bar) (flowrange @ ±2% accuracy: 0.1 - 25 Litres/min), all wired with 5-metre cable to flowmeter and 1 metre power cord.
Optional SSB Stainless Steel outer enclosure housing the FRT303.
Prices and specifications may change without notice. ManuFlo CATALOGUE 2019-20 v1.0 ManuFlo ®™
See www.manuelectronics.com.au for product data sheets. All prices in AUD$, and exclude GST 39
4.7 TMP Auto Batching Custody Transfer Ticket Printer System (used primarily with electromagnetic flowmeters)
Contains:
ME3000 / ME999
TMP
ME3000 Batch Controller ( or soon with optional ME999 )
o 6 digit LCD Microprocessor Batch Controller. Panel mount. IP64.
o Front keypad. Displays in ml / L / kL / Gal with decimal point.
o Number of batch ticket copies is user programmable.
o Fully programmable functions. With logic, pulse, and current output options. o with RS232 serial connector for ticket printer output (date/time/batch).
TTP-A5 o thermal ticket printer, with power supply.
o for cusody transfer dockets.
all wired and mounted in a IP64 hinged lockable powder-coated steel box.
TMP
FLOWMETERPUMP and/or
SOLENOID
Batch Controller
Printer
Ideal with a range of flowmeters
e.g. MFS50
Order Code Description
TMP-DC ME3000 Batch Controller and TTP-A5 printer Fully wired and mounted in a hinged lockable box.
12-24VDC powered.
TMP-AC ME3000 Batch Controller and TTP-A5 printer
Fully wired and mounted in a hinged lockable box.
240vac powered
Optional
-FP Optional front RS232 port, so batch log can be downloaded to a laptop.
Includes DB9 serial to USB converter for laptops without a serial port.
-FP Front Port
UPS-DC
Example batch ticket
-ESS Stainless Steel 316 enclosure, instead of powder coated (300mm W x 400mm H x 200mm D).
-USG Display in US Gallons and 110vac powered system
UPS-DC Uninterruptable Power Supply. 24VDC to 14.5 VDC. 4.5 Ah, 3hrs backup @ 1.5A
UPS-AC Uninterruptable Power Supply. 240VAC to 14.5 VDC. 4.5 Ah, 3hrs backup @ 1.5A
SPARES/ACCESSORIES
T-TP50 Thermal Paper for TTP-A5 thermal ticket printer (box of 50 rolls)
T-TP Thermal Paper for TTP-A5 thermal ticket printer (single roll)
Prices and specifications may change without notice. ManuFlo CATALOGUE 2019-20 v1.0 ManuFlo ®™
See www.manuelectronics.com.au for product data sheets. All prices in AUD$, and exclude GST 40
4.8 TMP-1 Manual Batching Custody Transfer Docket Printer System (single channel)
For manual batching.
Ideal for delivery trucks or loading and discharge locations where a custody transfer docket is required.
At the end of each manual batch, the TMP-1 (after a settable period of wait time if there is no activity i.e. flow of liquid stops) automatically provides batch quantity printout with date, time and Batch ID.
Number of batch ticket copies is user programmable.
Front keypad. Displays in ml / L / Gal with decimal point.
TMP-1
Contains:
ME6008M1 1-channel Batch Monitor Printer Driver Unit , with
optional front serial port to download internal log of 500 batches to a laptop.
TTP-A5 thermal docket printer, with power supply. all wired and mounted in a IP64 hinged lockable powder-coated steel box (300mm W x 300mm H x 200mm D).
Order Code Description
TMP-1
FLOWMETER
Batch Monitor
Printer
TMP-1-DC ME6008M1 1-channel Batch Monitor Printer Driver Unit and TTP-A5 printer, fully wired and mounted in a hinged lockable box.
12-24VDC powered.
TMP-1-AC As above, but 240vac powered
TMP-1-110 As above, but 110vac powered
Optional
-FP Optional front RS232 port, so batch log can be downloaded to a laptop.
Includes DB9 serial to USB converter for laptops without a serial port.
-FP Front Port
Ideal with a range of flowmeters
e.g. KMS50, MES40
-ESS Stainless Steel 316 enclosure, instead of powder coated (300mm W x 400mm H x 200mm D).
UPS-DC Uninterruptable Power Supply. 24VDC to 14.5 VDC. 4.5 Ah, 3hrs backup @ 1.5A
example
batch
ticket
UPS-AC Uninterruptable Power Supply. 240VAC to 14.5 VDC. 4.5 Ah, 3hrs backup @ 1.5A
SPARES/ACCESSORIES
T-TP50 Thermal Paper for TTP-A5 thermal ticket printer (box of 50 rolls)
T-TP Thermal Paper for TTP-A5 thermal ticket printer (single roll)
Admixture tradewaste water - clean water - recycled fuel
other: ________________________________________
Does the liquid have unusual properties? corrosive contains fibrous matter has suspended particles viscous other: ________________________________________________________________
* What is the pipe size (mm)?
20 25 32 40 50 80 100 150 other _________ (mm)
What is the type of pipe?
Galvanised Iron PVC Stainless Steel other: _____________________
What flowmeter connection type is needed to connect to the pipe? flanges hose threaded other: _________________________________
* What is the expected flowrange: ______________ to _____________ Litres/min
What measurement accuracy is required? ±1% ±2% ±5% other: _____%
What is the temperature: of the liquid? _________ ºC, of ambient _______ ºC
What type of output is required? pulse 4-20mA High/Low Flow alarm
* Do you want to display:
Flowrate: Flowrate units? e.g. Litres/Min __________
Total: Total units? e.g. Litres _____________
Is total to be resetable? yes no
Grand Total: Grand Total units? e.g. KL ____________
Where is the display to be located? integral remote, under 2 metres away remote, ______ metres away
* What type of power supply is required? internal battery (i.e. no external power)
external DC : 5-25V 12 V other: _________
external AC: 240v 110v other: _________
Is the flowmeter to be connected to other equipment? Batch Controller PLC/Computer Flowrate Indicator Totaliser Indicator
other: _____________________________________
* Where is the meter to be delivered? for freight estimate
_______________________________________________
city state country
* Your Name: ___________________________________
* Company: _____________________________________
Fax: ( ) _____________ * phone: ( ) _____________
email: __________________________________________
Other requirements: e.g. IP Rating ________________________________________________________________________________________________